Shown with Optional Cabinet Mantel/Hearth
flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
by a qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Save this manual for future reference. Save this manual for future reference.
Base Accessory



Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269

Figure 1 - Vent-Free Gas Compact Fireplace
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com


ASSEMBLY

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.
This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace.
ASSEMBLING FIREPLACE
This fireplace has a thermostat sensing bulb and a control valve. The thermostat will automatically modulate the heat output to maintain a consistent room temperature. This results in greater fireplace comfort. This can also result in lower gas bills.
Installing Log 1. Lift screen up and pull out to remove. 2. Cut two plastic straps to remove the log from the firebox cavity. 3. An optional blower is available. See Accessories, page 29. In- stall optional blower now. Follow installation instructions pro- vided with blower. 4. Remove log packaging material and discard packaging. Gently place log set on burner support (see Figure 3). The log should fit flat against top of burner support and log locator tabs fit into the slots under the log. Do not allow log to contact flame. If flame contacts log, soot will be created. 5. Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.
1. Remove log box and fireplace from carton. IMPORTANT: The fireplace hood is inside the cardboard protective end wrap on the left side of fireplace (as viewed from front). A decal is on the outside of the cardboard end wrap stating hood is enclosed (see Figure 2). 2. Remove hood from cardboard protective end wrap as shown in Figure 2. 3. Remove all protective packaging applied to fireplace for shipment. 4. Make sure your fireplace includes one hardware packet. 5. Check fireplace for any shipping damage. If fireplace is dam- aged, promptly inform dealer where you bought fireplace.


Burner Support with Log Locator Tabs
Cardboard Protective Fireplace End Wrap
Figure 2 - Removing Fireplace Hood
Figure 3 - Assembling Fireplace
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Log


ASSEMBLY Assembling Fireplace (Cont.) AIR FOR COMBUSTION AND VENTILATION
Assembling Hood 1. Locate four black phillips sheet metal screws from the hard- ware packet. 2. Rotate hood as shown in Figure 4. Make sure hood tabs point toward fireplace. 3. Insert hood tabs between baffle and louvers (see Figure 4). 4. Gently rotate hood to upright position. Make sure hood tabs are behind louvers and hood is resting on firebox top (see Figure 4). 5. Align screw holes on hood with screw holes on firebox top. 6. Insert screws as shown in Figure 4. Tighten screws firmly.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space

The information on pages 5 through 7 will help you classify your space and provide adequate ventilation.
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable win- dows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
Figure 4 - Assembling Hood

If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 7.
If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Fireplace Location, page 6.
Today’s homes are built more energy efficient than ever. New materi- als, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Firebox Top


Providing Adequate Ventilation (Cont.) Determining Fresh-Air Flow for Heater Location
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws com- bustion air from the outdoors and vents to the outdoors.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
Btu/Hr (maximum the space can support)
Btu/Hr (actual amount of Btu/Hr used)
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
56,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/ Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
Length x Width x Height = cu. ft. (volume of space)
Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.
If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.
B. Vent room directly to the outdoors. See Ventilation Air From Out- doors, page 7.
(volume of space) x 20 = (Maximum Btu/Hr the space
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
30,000 26,000 56,000 · can support)



This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 5). You can also remove door into adjoining room (see option 3, Figure 5). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 6 - Ventilation Air from Outdoors Shown with Optional Mantel

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, page 9)
Figure 5 - Ventilation Air from Inside Building Shown with Optional Mantel
Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Outlet Air


IMPORTANT: Vent-free fireplaces add moisture to the air. Although this is beneficial, installing fireplace in rooms without enough venti- lation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.

* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 29.

0" Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material
You can recess firebox into the wall. You can also position fireplace in the optional cabinet or corner mantels. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual. Purchase the optional mantel from your dealer (see Accessories, page 29).
Figure 7 - Mounting Clearances As Viewed From Front of Fireplace Shown Built In The Wall

0" Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material
Figure 8 - Mounting Clearances As Viewed From Front of Fireplace Shown with Optional Mantel
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com


3. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. 4. If you have not assembled firebox, follow instructions on page 4. 5. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening. 6. Attach flexible gas line to fireplace gas regulator. See Con- necting to Gas Supply, page 14. 7. Bend four nailing flanges on outer casing with pliers (see Figure 11). 8. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange. 9. Check all gas connections for leaks. See Checking Gas Con- nections, page 16. 10. If using optional brass trim kit, install the trim after final fin- ishing and/or painting of wall. See instructions included with brass trim accessory for attaching brass trim.
Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. An optional brass trim kit accessory is available (see Accesso- ries, page 29). Brass trim will extend past sides of fireplace approxi- mately 1/2 inch. This will cover the rough edges of the wall opening. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 12, page 10. Follow the instructions below to install the fireplace in this manner. Note: Your Comfort Glow fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace.
Height 26" 26 7/8"
Front Width 26 3/4" 26 7/8"
Depth 9 1/2" 10 1/2"
Bottom 3/4" 3/4"
10 1/2"
365/8" 257/8"
513/4" 267/8" 1. Frame in rough opening. Use dimensions shown in Figure 9 for the rough opening. If installing in a corner, use dimensions shown in Figure 10 for the rough opening. The height is 26 7/8" which is the same as the wall opening above. 2. If installing GA3450T blower accessory, do so at this time. Fol- low instructions included with blower accessory. Note: If not installing blower accessory, you may wish to run electrical wir- ing to your fireplace for future blower installation (see Accesso- ries, page 29). Use only approved three-wire electrical wiring. Note: A qualified installer should make all electrical connections.
267/8"
3/4" Off The Floor Minimum
Figure 10 - Rough Opening for Installing in Corner
267/8"
Figure 9 - Rough Opening for Installing in Wall


Nails or Wood Screws
Figure 11 - Attaching Fireplace to Wall Studs
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Actual Framing


Built-In Fireplace Installation (Cont.) Mantel Clearances for Built-In Installation Optional Mantel Installation

10" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.

Figure 12 - Minimum Mantel Clearances for Built-In Installation
OPTIONAL MANTEL INSTALLATION Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installation. Refer to instructions on page 4 for firebox assembly. Blower accessory should be installed if it is being used (see Installing Blower Accessory GA3450T, pages 11 through 13). 1. Unscrew four brass screws that attach top louver to fireplace. Remove louver from fireplace and set aside. 2. Place fireplace on wood base. 3. Place mantel around fireplace/base assembly. 4. Assemble brass trim kit. See Assembling Brass Trim, page 11. 5. Firmly snap brass trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 13).
If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.


Hole for 3" Wood Screw for Attaching Fireplace to Mantel
Hole for 3" Wood Screw for Attaching Fireplace to Wooden Base
Figure 13 - Attaching Brass Trim to Fireplace
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Mantel Shelf · Side of Firebox · Shoulder Screws


6. Align brass trim kit for flush fit around opening. 7. Use two 3" wood screws provided and attach fireplace base to wooden base (see Figure 13, page 10). 8. Remove brass trim kit and mantel. Be careful not to damage wall or mantel. 9. Place wood base next to wall at installation location. 10. Attach wood base to floor with two 1 3/4" black screws provided (see Figure 14). If the floor is concrete use anchor method (see Attaching Wood Base to Solid Floor, page 14). 11. Install gas line. See Connecting To Gas Supply, page 14. 12. Check for leaks. See Checking Gas Connections, page 16. 13. Place mantel around fireplace. Be careful not to damage wall or mantel. 14. Place brass trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the brass trim over the shoulder screws on fireplace (see Figure 13). 15. Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. The openings are located at top behind the area for the louvers (see Figure 13, page 10). 16. Reinstall top louvers.

Removing Upper Louver Assembly
To install the blower accessory, you must first remove the upper louver assembly. 1. Lift screen off heater. 2. Remove 4 screws from louver assembly (see Figure 16). Save these screws. 3. Pull louver assembly straight out from the cabinet. Be careful not to scratch the paint. Set louver assembly and screws aside.
1 3/4" Screw
Blower Bracket Mounting Holes

Figure 14 - Attaching Wood Base to Floor
ASSEMBLING BRASS TRIM (Brass trim shipped with mantel) 1. Remove packaging from three remaining pieces of brass trim. 2. Locate two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 15. 4. Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 15). 5. Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 15). 6. While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver. 7. Repeat steps 1 through 6 for other corner. 8. Set brass assembly aside for later installation.
Figure 16 - Removing Upper Louver Assembly
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com


Removing Valve Cover Shield 1. Open bottom louver assembly by swinging the assembly down (see Figure 17). 2. Using short Phillips screwdriver, remove the screw under the center of the branch support. Rotate valve cover shield clock- wise and slide out. IMPORTANT: Do not remove shoulder screw on the left side of valve cover shield. Slide the valve cover shield off of the shoulder screw (see Figure 17). Note: If you do not have a short Phillips screwdriver, the screen, log set, and branch support must be removed so a longer screw- driver may be used. See Connecting Equipment Shutoff Valve to Heater Control, page 15, steps 1 and 2.
3. Note the wire locations on back of AUTO/OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 1 and blue wire from terminal 3. Black wire can remain on middle terminal 2 (see Figure 18). 4. Carefully disconnect green and white wires at their insulated connectors. 5. In top of the heater cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket assembly to the outer casing with 4 #10 screws provided (see Figure 18). 6. Route the wire harness through the hole in left side of baffle. Pull wire harness through lower opening above where the valve shield was removed. (see Figure 18). 7. Insert the 4 wire harness into one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield (see Figure 18). 8. Reconnect red wire to switch position 3. Reconnect blue wire to switch position 1. Reconnect green and white wires.
Wiring Routing Hole in Baffle
Figure 17 - Removing Valve Cover Shield
Figure 18 - Installing Blower Bracket Assembly
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com


9. Install the switch plate on the valve cover shield with 2 #10 screws provided (see Figure 19). Reinstall the valve cover shield. Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 18, page 12). Plug fan kit into 120-Volt grounded power supply and test operation. Note: When switch is in the AUTO position, the fan will start after the heater has run for a few moments. The fan will continue to run for several moments after the heater has been turned off. When switch is in the ON position, the fan will run until turned to OFF. Reinstall upper louver assem- bly and hood if previously removed, (see Figure 16, page 11). Close lower louver door.
5. Plug power cord to the outlet receptacle (not provided) as shown in Figure 21. Wind the extra cable in power cord and and tie it up with the plastic wire strap (see Figure 21). Set the cable bundle between the burner bracket and outer casing, away from the burner. 6. Reinstall valve cover shield. 7. Test to make sure the blower is working properly. 8. Reinstall upper louver assembly and hood if previously removed, (see Figure 16, page 11). Close lower louver door.


Figure 20 - Wiring Diagram For Blower Accessory Built-In Installation
Figure 19 - Installing Switch Plate to Valve Cover Shield
Follow instructions in Removing Valve Cover Shield, page 12, then 1. Install a snap bushing found in hardware kit into one of the holes found on rear of valve cover shield. The other hole is for a strain relief clamp (not supplied) to secure incoming electri- cal supply. 2. Follow steps 2 through 6 in Installing Blower Assembly, begin- ning on page 12. Also remove black wire from middle switch terminal 2. 3. Remove black plastic strain relief and power cord from switch plate. The power cord supplied will not be used in built-in in- stallations. Pop in the plastic snap bushing found in hardware kit into the hole left by supply cord/strain relief. 4. A licensed electrician must follow the wiring diagram to con- nect incoming electrical supply to fan kit wiring harness (see Figure 20). Figure 21 - Installing Blower Bracket Assembly
Valve Cover Shield Box Cover Wire Harness
Clamp Connector (not included)
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com


Installing Blower Accessory - GA3450T (Cont.) Attaching Wood Base to Solid Floor Connecting to Gas Supply
For propane/LP units, installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent point- ing down as shown in Figure 23. Pointing the vent down protects it from freezing rain or sleet.
Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

For attaching base to solid floors (concrete or masonry)
Note: Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace. 1. Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep. 2. Fold floor anchor as shown in Figure 22. 3. Insert floor anchor (wings first) into hole. Tap anchor flush to floor. 4. Insert mounting screws through base and into floor anchors. 5. Tighten screws until base is firmly fastened to floor.
Figure 22 - Folding Anchor
Figure 23 - External Regulator with Vent Pointing Down
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 24).
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Vent Pointing Down


INSTALLATION Connecting to Gas Supply (Cont.) Connecting Equipment Shutoff Valve to Heater Control
We recommend that you install a sediment trap in supply line as shown in Figure 24. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*

PROPANE/LP From External Regulator (11" W.C. to 14" W.C. Pressure)

NATURAL From Gas Meter (5" W.C. to 10.5" W.C. Pressure)
Pipe Cap Tee Nipple Joint
Figure 24 - Gas Connection
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 29.
Figure 25 - Removing Log Base Assembly From Fireplace
To Fireplace Gas Regulator Equipment Shutoff Valve Provided by Installer
PROPANE/LP To External Regulator
Flexible Gas Line from Fireplace Gas Regulator Provided with Fireplace

Figure 26 - Attaching Flexible Gas Line to Equipment Shutoff Valve
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Shoulder Screw · Sediment Trap · Flexible Gas Line


Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 27). 2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to thermostat gas valve (see Figures 28 and 29). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light fireplace (see Operating Fireplace, pages 17 and 18). Check all other internal joints for leaks. 7. Turn off fireplace (see To Turn Off Gas to Appliance, page 18). 8. Replace front panel.

Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping sys- tem. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/ LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 4. Check all joints of gas supply piping system. Apply a noncor- rosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.
Figure 27 - Equipment Shutoff Valve

Figure 28 - Checking Gas Joints Shown with Optional Mantel (Propane/LP Gas)
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 27). 2. Pressurize supply piping system by either opening propane/ LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 3. Check all joints from gas meter for natural or propane/LP sup- ply to equipment shutoff valve (see Figures 28 and 29). Ap- ply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Figure 29 - Checking Gas Joints Shown with Optional Mantel (Natural Gas)
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Equipment Shutoff Valve · Open · Closed


5. Turn control knob counterclockwise to the PI- LOT position. Press in control knob for five (5) seconds (see Figure 30). Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ig- nitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor but- ton until pilot lights. Note: If pilot does not stay lit, refer to Troubleshooting, pages 20 through 22. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Pro- cedure, page 18. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. This fire- place has a safety interlock system. Wait one (1) minute before lighting pilot again. 8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.


Figure 30 - Control Knob In The OFF Position
Figure 31 - Pilot
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com


To Turn Off Gas To Appliance Thermostat Control Operation Manual Lighting Procedure INSPECTING BURNER
INSPECTING BURNER
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
TO APPLIANCE
Figure 32 shows a correct pilot flame pattern. Figure 33 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.
Shutting Off Fireplace 1. Turn control knob clockwise Clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed.
Turn control knob clockwise Clockwise to the PILOT position.
The thermostatic control used on this fireplace differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this fireplace senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the heater will cycle back on when room temperature drops below the set temperature.
Figure 32 - Correct Pilot Flame Pattern (Propane/LP Shown)
Figure 33 - Incorrect Pilot Flame Pattern (Propane/LP Shown)
The control knob can be set to any heat level between HI and LO.
Figure 34 shows a correct burner flame pattern. Figure 35 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows sporadic, irregular flame tipping. The flame should not be dark or have an orange/reddish tinge.
PROCEDURE
Figure 34 - Correct Burner Flame Pattern
Figure 35 - Incorrect Burner Flame Pattern
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Thermocouple Pilot Burner · Thermocouple Pilot Burner


CLEANING AND MAINTENANCE Cleaning Burner Injector Holder and Pilot Air Inlet Hole
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 37). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Primary Air Inlet Holes
Figure 36 - Injector Holder On Outlet Burner Tube
Pilot Assembly Pilot Air Inlet Hole
The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 36). 3. Blow air through the ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.
Figure 37 - Pilot Inlet Air Hole (Propane/LP Shown)
Air Passageways • Use a vacuum cleaner or pressurized air to clean.
Exterior • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Injector Holder · Ports/Slots · Burner Tube



POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see Cleaning and Maintenance, page 19) or replace ODS/ pilot assembly
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com


POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
Delayed ignition of burner
Burner backfiring during combustion
Yellow flame during burner combustion
Slight smoke or odor during initial operation
Fireplace produces a whistling noise when burner is lit
White powder residue forming within burner box or on adjacent walls or furniture
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com



POSSIBLE CAUSE
REMEDY
Fireplace produces a clicking/ticking noise just after burner is lit or shut off
Fireplace produces unwanted odors
Fireplace shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Moisture/condensation noticed on windows
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com


CGCFTP CGCFTN Btu (Variable) 14,000/26,000 14,000/26,000 Type Gas Propane/LP Only Natural Only Ignition Piezo Piezo Pressure Regulator Setting 8" W.C. 3" W.C. Inlet Gas Pressure (in. of water)*
Maximum 14" 10.5" Minimum 11" 5" Dimensions, Inches (H x W x D)
Fireplace 25 7/8 x 26 13/16 x 9 3/8 25 7/8 x 26 13/16 x 9 3/8 Carton 32 5/8 x 27 3/16 x 11 5/8 32 5/8 x 27 3/16 x 11 5/8 Weight, pounds
Fireplace 44 1/2 lbs. 44 1/2 lbs. Shipping 48 lbs. 48 lbs.
* For purposes of input adjustment
SERVICE HINTS
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040 for referral information.
You may feel your gas pressure is too low. If so, contact your local propane/LP or natural gas supplier.
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ technical service web site at www.desatech.com
Usually, we will ask you to return the part to the factory.
Contact authorized dealers of this product or Parts Central (see page 26). If they can’t supply original replacement part(s) call DESA Heating Products at 1-866-672-6040 for referral information.
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com



111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

PARTS LIST Models CGCFTP and CGCFTN
KEY PART NUMBER NO. CGCFTP CGCFTN DESCRIPTION QTY.
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual.
1 102633-02 102633-02 Outer Casing Top 1 2 102624-02 102624-02 Outer Casing 1 3 099230-02 099230-02 Shoulder Screw 14 4 098304-01 098304-01 Screw, #10 x 3/8" 16 5 109824-05 109824-05 Burner 1 6 103209-01 103209-01 Louvered Door 1 7 102635-02 102635-02 Left and Right Side Front 2 8 M11084-26 M11084-26 Hex Head Screw, #10 x 3/8" 28 9 103209-05 103209-05 Top Louver 1 10 104281-02CK 104281-02CK Firebox Hood 1 11 102638-01 102638-01 Firebox Top 1 12 104286-01 104285-01 ODS/Pilot Assembly 1 13 ** ** Firebox Wrapper 1 14 099211-01 099211-01 Control Bracket Screw 2 15 103963-01 103963-01 Inlet Tube 1 16 102834-01 102834-01 Outlet Tube 1 17 101629-02 101629-02 Bushing 1 18 098303-02 098303-02 Regulator Screw 2 19 ** ** Outer Shell Base 1 20 102649-02 102649-02 Branch Support 1 21 099415-09 099415-10 Gas Regulator 1 22 102875-01 102875-01 Regulator Bracket 1 23 101381-01 101381-01 Valve Cover and Piezo 1 24 099387-11 099387-11 Pilot Tube 1 25 098271-06 098271-06 Ignitor Cable 1 26 107186-01 107186-02 Injector 1 27 101629-01 101629-01 Bushing 1 28 098249-01 098249-01 Nut, M5 2 29 098522-26 098522-23 Gas Valve 1 30 102639-01 102639-01 Baffle 1 31 101628-01 101628-01 Flexible Connector 1 32 102869-01 102869-01 Control Bracket 1 33 102731-01 102731-01 Control Shield 1 34 103295-03CK 103295-03CK Screen Assembly 1 35 107154-01 107154-01 Log Set 1 36 104313-01 104313-01 Hinge, Right 1 37 104313-02 104313-02 Hinge, Left 1 38 M10908-2 M10908-2 Hinge Screws 4 39 103734-01 103734-01 Burner Support 2 40 097809-03 097809-03 3/8" NPT x 3/8" Flare Brass Fitting 1 41 101006-02 101006-02 Bracket, Pilot 1 42 098304-03 098304-03 Screw, #8 x 3/8" 4 43 ___ 107634-02 NG Conversion Plate 1 44 M10908-75 M10908-75 Hex wsr head tapping screw 1
101054-01 101054-01 Lighting Instructions Plate 1 100563-01 100563-01 Warning Plate 1 103470-01 103470-01 Hardware Package 1
** Part not available for field replacement.
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com


These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department
FBD 1349 Adams St. Bowling Green, KY 42103-3413 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 Parts Department sales@portableheaterparts.com techservice@portableheaterparts.com
Laportes Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 803-332-0191 Parts Department
Master Parts Distributors 1251 Mound Ave. NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner’s Registration Form and mail to the address on the back of this owner’s manual. Please provide the following product information:
Date Purchased: Note: Keep receipt for warranty verification.
Serial Number: 7 or 9 digit number located on product or identification tag.
Address:
E-Mail:
Please answer the following questions to register your product with DESA Heating Products:
❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other
❍ 100,000 to 250,000 ❍ Over 250,000
❍ Fireplace or Hearth Shop ❍ Farm Store ❍ Other
❍ Emergency Back-Up Heat ❍ Heater was on Sale ❍ Energy Savings/High Efficiency ❍ Construction Project ❍ Other
❍ $50,000 to $74,999 ❍ $75,000 to $99,999 ❍ $100,000 and Over
Not Important Somewhat Important Very Important
Availability Price Brand Name Overall Quality Heat Output Made in USA Warranty Local Service Value for Price Prior Brand Experience Controls Location Thermostat, Remote, or Manual Operation Ease of Operation Special Features Salesperson’s Recommendation Friend/Relative’s Recommendation Portability Quiet Operation
❍
❍
❍
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com


2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
Postage Required



Purchase these fireplace accessories from your local dealer or Parts Central (see page 26). If they cannot supply these accessories call DESA Heating Products’ Sales Department at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.
Stained Oak Veneer - GMC60F Unfinished Birch Veneer GMC61U The hardwood mantel and full hearth base feature fluted legs and crown molding. Available in medium stained oak, white lacquer finish, and unfinished hardwood, ready to stain or paint. Complete assembly instructions included. Three-sided brass trim kit included.
For all models. Equipment shutoff valve with 1/8" NPT tap.

Optional four-sided brass trim kit for built-in installations. Provides a finished appearance covering rough edges of wall opening.
Stained Oak Veneer - GMC64F Unfinished Birch Veneer GMC63U
Space-saving mantel and full hearth base corner design offers classic styling. Available in stained oak or unfinished hardwood, ready to stain or paint. Complete assembly instructions included. Three-sided brass trim kit included.
For all models. Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operating instructions included.
For all models. A care and maintenance video is available by calling 1-866-672-6040. You may also email your request to productsupport@desaint.com.
For all models. Your vent-free gas appliance requires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com



Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA Heating Products warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this fireplace to proper operating condition and an allowance for labor when provided by a DESA Heating Products Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING PRODUCTS’ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
111044-01 Rev. D 09/03
111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com
111044 01
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.