OWNER’S OPERATION AND INSTALLATION MANUAL
® RFP28TC 14,000 to 28,000 Btu/Hr with Thermostat
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Shown with Optional · Mantel featuring · Built-in Base

10. Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching. 11. Carefully supervise young children when they are in same room with heater. 12. Make sure screen is in place before run- ning heater. 13. Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture. 14. Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 15. Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater. 16. Operating heater above elevations of 4,500 feet may cause pilot outage.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to propane/LP gas. The odor helps you detect a propane/LP gas leak. However, the odor added to propane/LP gas can fade. Propane/ LP gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
2 103509

PRODUCT FEATURES
Lighting and Warning Plates
Operation This heater is clean burning. It requires no outside venting. This heater has been tested and approved ANS Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters.
ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f SDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f
ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f SDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f ASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'fASDFKIGLFJI alskdidkoemkgo dkirlnfgpd'f
Safety Pilot This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
Piezo Ignition System This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
Thermostatic Heat Control This heater has a thermostat sensing bulb and a control valve. This results in the great- est heater comfort. This can also result in lower gas bills.
Figure 1 - Vent-Free Gas Log Propane/LP Gas Space Heater
UNPACKING
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269

Attaching Brass Front Trim to Front Panel 1. Locate brass front trim in brass trim package. 2. Slide the head of two truss-head screws from hardware packet into each end of brass front trim (see Figure 5). 3. Line up screws with holes in front panel (see Figure 4). Insert screws in holes. Attach nuts from inside of front panel. Tighten with wrench.
Removing Front Panel Of Heater 1. Remove two screws near bottom cor- ners of front panel with Phillips screw- driver. 2. Pull bottom of front panel forward, then down (see Figure 2) .

Figure 3 - Attaching Ignitor Cable to Piezo Ignitor

Figure 5 - Attaching Brass Front Trim to Front Panel
Figure 2 - Removing Front Panel of Heater

Note: For easier installation, lay heater on its back. 1. Remove log from inside top of heater. Discard protective packaging. 2. Attach ignitor cable to piezo ignitor (see Figure 3). 3. With Phillips screwdriver, remove four screws holding screen in place. Re- move screen. 4. Gently slide log between log retaining brackets on deflector assembly (see Fig- ure 4). The log should fit firmly against bottom of log retaining brackets. 5. Reattach screen using four screws re- moved in step 3.
Figure 4 - Assembling Heater

Assembling and Attaching Brass Trim 1. Remove packaging from three remain- ing pieces of brass trim. 2. Locate four brass screws, two adjust- ing plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 6. 4. Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 6). 5. Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 6). 6. While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver. 7. Repeat steps 1 through 6 for other side. 8. Place the assembled trim on front of heater cabinet. Attach on top and sides with four brass screws included in hard- ware package (see Figure 7). 9. Reattach front panel to heater if you are going to mount the heater to the base. Do not reattach front panel at this time if you are going to mount heater to wall.
Slot Mitered Edge Slot
Figure 6 - Assembling Brass Trim
Figure 7 - Attaching Brass Trim to Heater

Confined and Unconfined Space
The National Fuel Gas Code (ANS Z223.1, 1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in- stalled*, through openings not furnished with doors, are considered a part of the unconfined space.
The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space
The information on pages 6 through 7 will help you classify your space and provide adequate ventilation.
Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Homeowners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, homeowners want their homes as airtight as possible.
This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.
Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.
If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 8.
If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow For Heater Location, page 7.
6 103509

Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. =51.2 or 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support) 58,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 8. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 8. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Continued · 7 103509

Ventilation Grills Into Adjoining Room,
Or Remove Door into Adjoining
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 8). You can also remove door into adjoining room (see op- tion 3, Figure 8). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 8 - Ventilation Air from Inside Building
Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.
Inlet Air Ventilated Crawl Space
Figure 9 - Ventilation Air from Outdoors

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
You can locate heater on floor. The optional hearth base is needed. You can also install the optional decorative mantel on the heater (some mantels require hearth base). IMPORTANT: Only use optional mantel and hearth base specified in this manual. Purchase the optional mantel and hearth base from your dealer. See Accessories, page 25.
An optional fan kit is available from your dealer. See Accessories, page 25. If plan- ning to use fan, locate heater near an electri- cal outlet.
The heater may also be mounted on a wall. You cannot use optional mantel if mounting heater on a wall.
CHECK GAS TYPE
6" Minimum From Sides Of Heater
Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater.
Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material
Minimum Of Carpet Combust
Figure 10 - Mounting Clearances As Viewed From Front of Heater
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 25.

Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.
There are three options for mounting this heater. A. Mounting heater to wall B. Mounting heater to optional hearth base C. Mounting heater with optional hearth base to optional mantel
The thermostat sensing bulb has been placed inside the heater for protection during shipping.
Locating Thermostat Sensing Bulb 1. Remove front panel of heater (see Fig- ure 2, page 4). 2. Locate thermostat sensing bulb just under burner assembly.
Mounting Bracket The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.
11" Min.
Attaching Thermostat Sensing Bulb 1. Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater. 2. Place clamp on thermostat sensing bulb as shown in Figure 11. Clamp is pro- vided in hardware package. 3. Snap clamp into upper mounting hole as shown in Figure 11. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.
Only Insert Mounting Screws Through Last
20 3/4" Min.
Hole On Each End
Figure 12 - Mounting Bracket Location
Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways. 1. Attaching to wall stud 2. Attaching to wall anchor
Figure 13 - Mounting Bracket Clearances
Attaching To Wall Stud This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.
For attaching mounting bracket to wall studs. 1. Drill holes at marked locations using 9/64" drill bit. 2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall. 3. Insert mounting screws through bracket and into wall studs. 4. Tighten screws until mounting bracket is firmly fastened to wall studs.
Attaching To Wall Anchor This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).
Figure 11 - Attaching Thermostat Sensing Bulb
Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Installing Bottom Mounting Screws 1. Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 17). 2. Mark screw locations on wall. 3. Remove heater from mounting bracket. 4. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 un- der Attaching To Wall Anchor Method. If installing bottom mounting screw into wall stud, drill holes at marked lo- cations using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacers between bottom mount- ing holes and wall anchor or drilled hole. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole. 8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 13 and 14).
For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2. Fold wall anchor as shown in Figure 14. 3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. 5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is firmly fastened to wall.
Figure 14 - Folding Anchor
Figure 15 - Popping Open Anchor Wings For Thin Walls
Mounting Bracket (attached to wall) Stand-Out Tab
Placing Heater On Mounting Bracket 1. Locate two horizontal slots on back panel of heater. 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.
Figure 16 - Mounting Heater Onto Mounting Bracket
Figure 17 - Installing Bottom Mounting Screws
Horizontal Slots · Continued · 11 103509

Securing Hearth Base to Floor 1. Position hearth base in desired location. Mark holes for drilling (See Figure 18, below). Remove hearth base. 2. For carpeted floor, make a small cut with a sharp knife at marked locations before drilling. If securing to a wood floor, drill a 3/4" deep hole using a 1/8" diameter drill bit. Do not use anchors in wood floors. If securing to a concrete floor, drill a 1 3/8" deep hole using a 1/4" diameter concrete drill bit. Completely insert anchors into each hole. 3. Mount heater to hearth base following steps under Mounting Heater to Op- tional Hearth Base. After mounting heater, position heater and hearth base over drilled holes. With slotted screw- driver, secure hearth base to floor with four wood screws.


WARNING: If installing the GHB802 or GHB802A base on heater, and using with a GA se- ries heater blower accessory along with a GS601 surround or a GM800 or GM900 series man- tel, the surround or mantel clear- ance to back wall should be 3/4 inch. This will improve flame appearance and combustion. Use only a GHB802B, GHB802C, OR GHB38 series hearth base if using a GA series heater blower accessory with a GM700 series, GMC32F series, or GMC33U se- ries mantel.
Figure 19 - Placing Hearth Insert on Heater Base and Attaching Brass Base Trim
Mounting Heater to Optional Hearth Base 1. Lay heater on its back on a table with the bottom of heater overhanging the edge of the table. 2. Remove 2 shipping screws in bottom of heater. Discard shipping screws. 3. Line up mounting holes on top of hearth base with holes in bottom of heater (see Figure 18). 4. Using a Phillips screwdriver, secure hearth base to heater with four sheet metal screws (see Figure 18). 5. Stand heater up on base. 6. Place hearth insert in hearth base as shown in Figure 19. 7. Assemble brass trim (see steps 1 through 7 under Assembling and At- taching Brass Trim, page 5). 8. Slide base trim on heater base. Attach brass trim to base with two brass screws included as shown in Figure 19 below.
C. MOUNTING HEATER WITH OPTIONAL HEARTH BASE TO OPTIONAL MANTEL See instructions included with mantel kit.
IMPORTANT: Only use the optional man- tels specified in this manual. See Accesso- ries, page 25 for proper mantel kits. This heater is only approved for use with models G M F 8 0 0 ( A , B ) / G M U 8 0 1 ( A , B ) , GM900F(A,B)/GM901U(A,B), GM700F/ GM701U, GMC22F/GMC23U/GMC24U, GMC32F(B)/GMC33U(B), and GMC26F/ GMC27U/GMC28F mantel kits. Using any other mantel will void the A.G.A. approval for this heater. Do not use models G M F 8 0 0 ( A , B ) / G M U 8 0 1 ( A , B ) , GM900F(A,B)/GM901U(A,B), and GM700F/GM701U, GMC22F/GMC23U/ GMC24U, GMC32F(B)/GMC33U(B), and GMC26F/GMC27U/GMC28F mantels with any other product. Before installing mantel to heater, the heater must be mounted on the optional hearth base.

Holes for Securing Heater to Floor
Figure 18 - Attaching Heater to Hearth Base
Hearth Insert · Screw · 12 103509

Install sediment trap in supply line as shown in Figure 21. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
WARNING: If installing the GHB802 or GHB802A base on heater, and using with a GA se- ries heater blower accessory along with a GS601 surround or a GM800 or GM900 series mantel, the surround or mantel clearance to back wall should be 3/4 inch. This will improve flame appear- ance and combustion. Use only a GHB802B, GHB802C, OR GHB38 series hearth base if using a GA series heater blower accessory with a GM700 series, GMC32F series, or GMC33U se- ries mantel.
Figure 20 - External Regulator with Vent Pointing Down NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes.
3/8" NPT Pipe Nipple
The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 20. Pointing the vent down protects it from freezing rain or sleet. Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 21). Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Reducer Bushing to 1/8" NPT
Manual Shutoff Valve *
Test Gauge Connection *
1/8" NPT Plug Tap
From External Regulator (11" W.C. to 14" W.C. Pressure)
Figure 21 - Gas Connection
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 25.

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Fig- ure 22). 2. Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve. 3. Check all joints from propane/LP sup- ply tank to manual shutoff valve (see Figure 23). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Pressure Testing Heater Gas Connections 1. Open manual shutoff valve (see Fig- ure 22). 2. Open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to thermostat gas valve (see Fig- ure 23). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 15 and 16). Check all other in- ternal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 15). 8. Replace front panel.

Figure 22 - Manual Shutoff Valve Thermostat Gas Valve Location

Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected. 3. Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Reconnect heater and manual shutoff valve to gas supply. Check reconnected fittings for leaks.

READ BEFORE
LIGHTING
C-clockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.
to the PILOT position. Press in control knob for five (5) seconds (see Figure 24). Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is at- tached to the front of burner. If needed, keep pressing ignitor but- ton until pilot lights. Note: If pilot does not stay lit, refer to Troubleshooting, pages 17 through 19. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 16.
Figure 25 - Pilot
TO APPLIANCE
Shutting Off Heater 1. Turn control knob clockwise Clockwise to the OFF position. 2. Turn off all electric power to the ap- pliance if service is to be performed.
Ignitor Button Control Knob
Turn control knob clockwise to the PILOT position.
PILOT
OFF
HI
IGNITOR
Figure 24 - Control Knob In The OFF Position
GRH/OV 015 Control Knob & Ignitor Button

INSPECTING BURNER
Figure 28 shows a correct burner flame pattern. Figure 29 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log.
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
The thermostatic control used on this heater differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or de- creases the burner flame height. At times the room may exceed the set tempera- ture. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set tem- perature. The control knob can be set to any heat level between HI and LO.
Figure 26 shows a correct pilot flame pattern. Figure 27 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.


Top of Flame About One Inch Above Logs

PROCEDURE
Figure 28 - Correct Burner Flame Pattern at High Position
Figure 27 - Incorrect Pilot Flame Pattern
Figure 29 - Incorrect Burner Flame Pattern at High Position
C-clockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.
Pilot Burner · 16 103509

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see Cleaning and Maintenance, page 20 or replace ODS/ pilot assembly
Continued · 17 103509

POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
Delayed ignition of burner
Burner backfiring during combustion
Yellow flame during burner combustion
Slight smoke or odor during initial operation
Heater produces a whistling noise when burner is lit
White powder residue forming within burner box or on adjacent walls or furniture
18 103509

POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Moisture/condensation noticed on windows
19 103509

SPECIFICATIONS BTU (Variable) 14,000/28,000
Type Gas Propane/LP Only
Pressure Regulator Setting 8" W.C.
Inlet Gas Pressure (in. of water) *
Maximum 14" Minimum 11"
Dimensions, Inches (H x W x D)**
Heater 23.75 x 25.9 x 8.5 Carton 26 x 27.75 x 10.25
Heater 29 Shipping 35
ODS/PILOT AND BURNER • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.
*For purposes of input adjustment **Measurement includes knobs and hood
TECHNICAL SERVICE
Air Passageways • Use a vacuum cleaner or pressurized air to clean.
You may have further questions about in- stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190.
Exterior • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.
Ignition Piezo · Weight (pounds) · 20 103509

PARTS CENTRALS
These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764 732-870-8809 1-800-755-8809
Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see right) or call DESA International’s Technical Service Depart- ment at 1-800-323-5190.
Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426
FBD 1349 Adams St. Bowling Green, KY 42103 502-846-1199 1-800-654-8534
Usually, we will ask you to return the defec- tive part to the factory.
Four Flags Power Products 1115 Stateline Road Niles, MI 49120 616-684-2697 1-800-268-4983 Parts Only
Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 610-430-7717 1-800-368-0803
Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see right) or call DESA International’s Parts Department at 1-800- 972-7879 for referral information.
LA Porte’s Parts & Service 2444 North 5th Street Hartsville, SC 29550 803-332-0191 Parts Department
Master Parts Distributors 1184 Wilson Ave. NW Grand Rapids, MI 49504 616-791-8270 1-800-446-1446
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911
Heater & Fireplace Stove 1922 N. Route 9 Cape May Court, NJ 07728-6129 609-624-0678
21 103509


22 103509

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual.
KEY NO. PART NUMBER DESCRIPTION QTY.
1 098304-01 Screw, #10 x 3/8" 6 2 100566-01CK Front Panel 1 3 100573-01BR Screen Assembly 1 4 100568-01BR Burner Shield 1 5 100903-04 Log 1 6 M11084-38 Screw, #8 x 3/8" 2 7 099066-01 Mounting Bracket 1 8 M11084-26 Screw, #10 x 3/8" 8 9 100571-01BR Deflector Unit 1 10 098271-03 Ignitor Cable 1 11 098249-01 Nut, M5 2 12 099440-06 ODS/Pilot Assembly 1 12-1 098514-01 Thermocouple 1 12-2 098594-01 Ignitor Electrode 1 13 099126-02 Burner 1 14 098517-01 3/16" Pilot Tubing 1 15 098251-03 Injector 1 16 098250-01 Injector Holder 1 17 099415-06 Pressure Regulator 1 18 099553-01 Pilot Shield 1 19 103255-01 3/8" Outlet (Burner) Tubing 1 20 103256-01 3/8" Inlet Tubing 1 21 103837-03 Bracket Support 1 22 098275-01 3/8" NPT Plug 1 23 098522-13 Thermostat Gas Valve 1 24 105556-01 Cabinet 1 25 097159-04 Piezo Ignitor 1 26 098304-03 Screw, #8 x 3/8" 5 27 101046-01 Log Strap 2
100562-01 Lighting Instructions Plate 1 100563-01 Warning Plate 1 101899-01 Brass Trim Assembly 1 100642-01 Hardware Package 1 100769-02 Brass Trim Hardware 1 100565-01 Warning Plate Fastener Kit 1 101416-29 Instructional Video 1
23 103509


Purchase these heater accessories from your local dealer. If they can not supply these accessories, either contact your nearest Parts Central (see page 21) or call DESA International’s Sales Department at 1-800- 458-2472 for information. You can also write to the address listed on the back page of this manual.
Provides better heat distribution. Makes heater more efficient. Complete installation and operating instructions included.
PRESTIGE MANTEL Unfinished - GMC23U Series Finished - GMC22F Series
Manual shutoff valve with 1/8" NPT tap.

For use with heater and hearth base. Sturdy hardwood construction embellished with fluted sides and bullet medallions. Available in a walnut finish or an unfinished hardwood, ready to stain or paint. Complete assembly and installation instructions included.


PRESTIGE MANTEL WITH BUILT-IN BASE Unfinished - GMC27U Series Finished - GMC26F Series Finished Oak - GMC28F
For locating heater on the floor. Includes brass trim. Complete installation instruc- tions included.
For use with heater. Features built-in base, sturdy hardwood construction with classic styling and attractive molding. Available in light oak finish, walnut finish, or an unfin- ished hardwood, ready to stain or paint. Complete assembly and installation instruc- tions included.
CORNER MANTEL with built in base Unfinished - GMC35U Series Finished - GMC34F Series
For use with heater and hearth base. Space- saving corner design featuring clean, classic lines. Available in a walnut finish or an unfinished hardwood, ready to stain or paint. Complete assembly and installation instruc- tions included.
24 103509


Serial No
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
103509 01 NOT A UPC
Model Date Purchased
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.