Table of Contents 76 sections VENT-FREE NATURAL GAS HEATER · OWNER’S OPERATION AND INSTALLATION MANUAL · Model: CGN10T and CGN10TL · CONTENTS SECTION PAGE · … ShowHide
VENT-FREE NATURAL GAS HEATERp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1Model: CGN10T and CGN10TLp.1CONTENTS SECTION PAGEp.2WARNING ICON G 001 DANGER Carbon monoxide poisoning may lead to death!p.2SAFETY INFORMATIONp.3WARNING ICON G 001 WARNINGS Continuedp.3PRODUCT IDENTIFICATIONp.4UNPACKINGp.4PRODUCT FEATURESp.4AIR FOR COMBUSTIONp.5WARNING ICON G 001 WARNINGp.5AND VENTILATIONp.5DETERMINING AIR FLOW FOR HEATER LOCATIONp.6INSTALLING TOp.9NOTICEp.9WALLp.9WARNING ICON G 001 WARNING Never install the heaterp.9WALL Continuedp.10CEILINGp.10FLOORp.10JOINING WALLp.10ANCHORp.11CONNECTINGp.13TO GAS SUPPLYp.13CHECKINGp.14GAS CONNECTIONSp.14PRESSURE TESTING GAS SUPPLY PIPING SYSTEMp.14PRESSURE TESTING HEATER GAS CONNECTIONSp.15ON POSITIONp.15OFF POSITIONp.15OPERATINGp.16FOR YOUR SAFETY READ BEFORE LIGHTINGp.16HEATERp.16LIGHTING INSTRUCTIONSp.16LOp.16PILOTp.16OFFp.16HIp.16IGNITORp.16TO TURN OFF GAS TO APPLIANCE OPERATINGp.18THERMOSTAT CONTROL OPERATIONp.18MANUAL LIGHTING PROCEDUREp.18INSPECTINGp.19BURNERp.19PILOT FLAME PATTERNp.19GRH/OV 009 GOOD PILOTp.19GRH/OV 008 BAD PILOT/LPp.191/2 GLASS HEIGHTp.20CORRECT FLAME PATTERNp.20AT HIGH POSITIONp.20INCORRECT FLAME PATTERNp.20CLEANINGp.21AND MAINTENANCEp.21ODS/PILOT AND BURNER ORIFICEp.21CABINETp.21TROUBLESHOOTINGp.21OBSERVED PROBLEMp.21POSSIBLE CAUSEp.21REMEDYp.21TECHNICALp.25SERVICEp.25SPECIFICATIONSp.25HINTSp.25PARTS LISTp.27CGN10T CGN10TLp.27PARTS AVAILABLE - NOT SHOWNp.27REPLACEMENTp.28PARTSp.28SERVICE PUBLICATIONSp.28PARTS CENTRALp.29NOTES _________________________________________________________________p.30WARRANTY INFORMATIONp.32KEEP THIS WARRANTYp.32LIMITED WARRANTY COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERSp.32103574-01 REV. A 3/97p.32
Page 1 of the Desa Tech CGN10TL user manual — VENT-FREE NATURAL GAS HEATER
Page 1 · click to enlarge
Page 1

VENT-FREE NATURAL GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

Model: CGN10T and CGN10TL

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. (I.E. Installation of this product is permitted after the manufactured (mobile) home is sited) This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

Save this manual for future reference.

®

Page 2 of the Desa Tech CGN10TL user manual — Table of Contents
Page 2 · Contents
Contents

Contents

VENT-FREE NATURAL GAS HEATERp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1Model: CGN10T and CGN10TLp.1CONTENTS SECTION PAGEp.2WARNING ICON G 001 DANGER Carbon monoxide poisoning may lead to death!p.2SAFETY INFORMATIONp.3WARNING ICON G 001 WARNINGS Continuedp.3PRODUCT IDENTIFICATIONp.4UNPACKINGp.4PRODUCT FEATURESp.4AIR FOR COMBUSTIONp.5WARNING ICON G 001 WARNINGp.5AND VENTILATIONp.5DETERMINING AIR FLOW FOR HEATER LOCATIONp.6INSTALLING TOp.9NOTICEp.9WALLp.9WARNING ICON G 001 WARNING Never install the heaterp.9WALL Continuedp.10CEILINGp.10FLOORp.10JOINING WALLp.10ANCHORp.11CONNECTINGp.13TO GAS SUPPLYp.13CHECKINGp.14GAS CONNECTIONSp.14PRESSURE TESTING GAS SUPPLY PIPING SYSTEMp.14PRESSURE TESTING HEATER GAS CONNECTIONSp.15ON POSITIONp.15OFF POSITIONp.15OPERATINGp.16FOR YOUR SAFETY READ BEFORE LIGHTINGp.16HEATERp.16LIGHTING INSTRUCTIONSp.16LOp.16PILOTp.16OFFp.16HIp.16IGNITORp.16TO TURN OFF GAS TO APPLIANCE OPERATINGp.18THERMOSTAT CONTROL OPERATIONp.18MANUAL LIGHTING PROCEDUREp.18INSPECTINGp.19BURNERp.19PILOT FLAME PATTERNp.19GRH/OV 009 GOOD PILOTp.19GRH/OV 008 BAD PILOT/LPp.191/2 GLASS HEIGHTp.20CORRECT FLAME PATTERNp.20AT HIGH POSITIONp.20INCORRECT FLAME PATTERNp.20CLEANINGp.21AND MAINTENANCEp.21ODS/PILOT AND BURNER ORIFICEp.21CABINETp.21TROUBLESHOOTINGp.21OBSERVED PROBLEMp.21POSSIBLE CAUSEp.21REMEDYp.21TECHNICALp.25SERVICEp.25SPECIFICATIONSp.25HINTSp.25PARTS LISTp.27CGN10T CGN10TLp.27PARTS AVAILABLE - NOT SHOWNp.27REPLACEMENTp.28PARTSp.28SERVICE PUBLICATIONSp.28PARTS CENTRALp.29NOTES _________________________________________________________________p.30WARRANTY INFORMATIONp.32KEEP THIS WARRANTYp.32LIMITED WARRANTY COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERSp.32103574-01 REV. A 3/97p.32
Page 3 of the Desa Tech CGN10TL user manual — WARNING ICON G 001 WARNINGS Continued
Page 3 · click to enlarge
Page 3

SAFETY INFORMATION

WARNING ICON G 001 WARNINGS Continued

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 3. Heater shall not be installed in a bathroom. 4. Never install the heater
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas 5. This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 8. 6. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion. 7. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced. 8. Do not run heater
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 9. Never place any objects on the heater. 10. Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching. 11. Carefully supervise young children when they are in same room with heater. 12. Make sure grill guard is in place before running heater. 13. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 14. Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. 15. Operating heater above elevations of 4,500 feet could cause pilot outage.
Page 4 of the Desa Tech CGN10TL user manual — PRODUCT FEATURES
Page 4 · click to enlarge
Page 4

PRODUCT IDENTIFICATION

Control Knob Ignitor Button

Figure 1 - Vent-Free Natural Gas Heater

LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1 also known as NFPA 54*.

*Available from: American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

UNPACKING

1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

PRODUCT FEATURES

Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Piezo Ignition System This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

Thermostatic Heat Control This heater has a thermostat sensing bulb and thermostat control. This results in the greatest heater comfort. This can also result in lower gas bills.

Show 4 more labels / short text on this page
Grill Guard · Glass Panel · Heater Cabinet · Front Panel
Page 5 of the Desa Tech CGN10TL user manual — AND VENTILATION
Page 5 · click to enlarge
Page 5

AIR FOR COMBUSTION

WARNING ICON G 001 WARNING

This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

AND VENTILATION

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

PROVIDING ADEQUATE VENTILATION The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space. The information on pages 5 through 8 will help you classify your space and provide adequate ventilation. Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continu-

ous water vapor retarder with a rating of one perm (6x10-11 per pa-sec- m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors

and c. caulking or sealants are applied to areas such as joints around window

and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide addi- tional fresh air. See Ventilation Air From Outdoors, page 8. If your home does not meet all of the three criteria above, proceed to page 6.

Confined and Unconfined Spaces The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1000 Btu per hour (4.8 cubic meters per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1000 Btu per hour (4.8 cubic meters per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.

Page 6 of the Desa Tech CGN10TL user manual — AND VENTILATION
Page 6 · click to enlarge
Page 6

AIR FOR COMBUSTION

DETERMINING AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.

AND VENTILATION

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1. Determine the volume of the space (length x width x height).

Length x Width x Height = cu. ft. (volume of space) Example: Space size 18 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2304 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2304 cu. ft. (volume of space) ÷ 50 cu. ft. = 46.1 or 46,100 (maximum Btu/Hr the space can support)

3. Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr

Example: Gas water heater 40,000 Btu/Hr Vent-free heater + 10,000 Btu/Hr Total = 50,000 Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used)

Example46,100 Btu/Hr (maximum the space can support) 50,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A. Rework worksheet, adding the space of an adjoining room. If the extra space provides

an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 8. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Page 7 of the Desa Tech CGN10TL user manual — AND VENTILATION
Page 7 · click to enlarge
Page 7

AIR FOR COMBUSTION

AND VENTILATION

VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Ventilation Grills Into Adjoining Room,

Or Remove Door into Adjoining

Figure 2 - Ventilation Air from Inside Building

Show 7 more labels / short text on this page
12" · Ventilation · Option 2 · Grills into Adjoining · Room, Option 1 · Room, Option 3 · 12"
Page 8 of the Desa Tech CGN10TL user manual — AND VENTILATION
Page 8 · click to enlarge
Page 8

AIR FOR COMBUSTION

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

AND VENTILATION

Inlet Air Ventilated Crawl Space

Figure 3 - Ventilation Air from Outdoors

Show 6 more labels / short text on this page
Ventilated Attic · Outlet Air · Outlet Air · To Attic · To Crawl Space · Inlet Air
Page 9 of the Desa Tech CGN10TL user manual — WARNING ICON G 001 WARNING Never install the heater
Page 9 · click to enlarge
Page 9

INSTALLING TO

NOTICE

WALL

A qualified service person must install heater. Follow all local codes.

CHECK GAS TYPE Use only natural gas. If your gas supply is not natural, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS Before installing heater, make sure you have the items listed below:

  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • manual shutoff valve *
  • ground joint union
  • test gauge connection * (see Figure 12, page 14)
  • sediment trap
  • tee joint
  • pipe wrench

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessory, page 28.

LOCATING HEATER This heater is designed to be mounted on a wall.

WARNING ICON G 001 WARNING Never install the heater

  • in a bathroom
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas
  • heater pilot and burner must be at least 18 inches above floor
  • locate heater where moving vehicle will not hit it
Page 10 of the Desa Tech CGN10TL user manual — FLOOR
Page 10 · click to enlarge
Page 10

INSTALLING TO

For convenience and efficiency, install heater

WALL Continued

  • where there is easy access for operation, inspection, and service
  • in coldest part of room

CEILING

6" Minimum From Sides Of Heater

Right Side Left Side

Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

FLOOR

Figure 4 - Mounting Clearances As Viewed From Front of Heater

THERMOSTAT SENSING BULB The thermostat sensing bulb is located inside the heater. Do not move this bulb during installation or operation of the heater.

INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater.

2. Mark two mounting screw locations on wall (see Figure 5).

8 7/8" Minimum To

JOINING WALL

20 1/4" Minimum To

FLOOR

Figure 5 - Mounting Screw Locations

Show 10 more labels / short text on this page
36" · Minimum · 3" · 7 3/4" · Maintain 6" · Clearance From Wall · Mounting · Screw Locations · Maintain 3" · Clearance From Floor
Page 11 of the Desa Tech CGN10TL user manual — ANCHOR
Page 11 · click to enlarge
Page 11

INSTALLING TO

Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater.

WALL Continued

Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2. Insert mounting screw into wall stud. 3. Tighten screw until 1/16" space (thickness of penny) is between screwhead and wall.

Attaching to wall anchor method Follow instructions below to attach mounting screws to hollow walls (wall areas between studs) or solid walls (concrete or masonry). 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep. 2. Fold wall anchor (see Figure 6).

Figure 6 - Folding Anchor

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 7). IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Thin Walls (1/4" to 1/2" thick)

Figure 7 - Popping Open Anchor Wings For Thin Walls

5. Tighten two screws until 1/16" space (thickness of penny) is between screwheads and wall (see Figure 8).

Thin or Thick Wall (thick wall shown)

ANCHOR

Figure 8 - Tightening Anchors

1/16" Space · Solid Wall

Page 12 of the Desa Tech CGN10TL user manual — WALL Continued
Page 12 · click to enlarge
Page 12

INSTALLING TO

Placing Heater On Mounting Screws 1. Locate two keyhole slots on back panel of heater (see Figure 9). 2. Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots.

WALL Continued

Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater

Removing Front Panel Of Heater 1. Remove two screws near bottom corners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pull bottom of front panel forward, then down.

Figure 10 - Removing Front Panel Of Heater

Installing Bottom Mounting Screw 1. Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 11). 2. Mark screw location on wall. 3. Remove heater from wall. 4. If installing bottom mounting screw into hollow or solid wall, install wall anchor. Follow steps 1 through 5 under Attaching To Wall Anchor Method, page 11. If installing bottom mounting screw into wall stud, drill hole at marked location using 9/64" drill bit. 5. Replace heater on wall. 6. Insert bottom anchor screw through back panel into bottom anchor or drilled hole (see Figure 11). 7. Tighten screw until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 13-15).

Figure 11 - Installing Bottom Mounting Screw

Keyhole Slots

Page 13 of the Desa Tech CGN10TL user manual — TO GAS SUPPLY
Page 13 · click to enlarge
Page 13

CONNECTING

TO GAS SUPPLY

Installation must include a manual shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 12, page 14).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Install sediment trap (trap) in supply line as shown in Figure 12, page 14. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contami- nants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Page 14 of the Desa Tech CGN10TL user manual — PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Page 14 · click to enlarge
Page 14

CONNECTING

TO GAS SUPPLY

3/8" NPT Pipe Nipple

Manual Shutoff Valve * From External Gas Meter (4" W.C. to 10.5" W.C. Pressure)

Reducer Bushing to 1/8" NPT

Test Gauge Connection *

1/8" NPT Plug Tap

Figure 12 - Gas Connection

* An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessory, page 28.

CHECKING

GAS CONNECTIONS

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

Show 9 more labels / short text on this page
Pressure Regulator · Heater Cabinet · Ground Joint Union · Tee Joint · Tee Joint · 3" Minimum · Pipe Nipple · Sediment Trap · Cap
Page 15 of the Desa Tech CGN10TL user manual — ON POSITION
Page 15 · click to enlarge
Page 15

CONNECTING

4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once.

TO GAS SUPPLY

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 13). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to manual shutoff valve (see Figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1. Open manual shutoff valve (see Figure 13). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to control valve (see Figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 16 through 18). Check the rest of the internal joints for leaks. 7. Turn off heater (see To Turn Off Gas To Appliance, page 18). 8. Replace front panel.

ON POSITION

OFF POSITION

Figure 13 - Manual Shutoff Valve

Figure 14 - Checking Gas Joints

Show 6 more labels / short text on this page
Open · Manual Shutoff Valve · Closed · Control Valve Location · Gas Meter · Manual Shutoff Valve
Page 16 of the Desa Tech CGN10TL user manual — LO
Page 16 · click to enlarge
Page 16

OPERATING

FOR YOUR SAFETY READ BEFORE LIGHTING

HEATER

A. This appliance has a pilot which must be lighted by hand. When lighting

the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure

to smell next to the floor because some gas is heavier than air and will settle on the floor.

  • WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use

tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately

call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
3. Turn control knob clockwise Clockwise to the OFF position.

LO

PILOT

OFF

HI

IGNITOR

Figure 15 - Control Knob In The OFF Position

Ignitor Button · Control Knob

Page 17 of the Desa Tech CGN10TL user manual — HEATER
Page 17 · click to enlarge
Page 17

OPERATING

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 16. If you don’t smell gas, go to the next step.

HEATER

5. Turn control knob counterclockwise C-clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 15, page 16).
6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Figure 16 - Pilot

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
  • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.
8. Turn control knob counterclockwise C-clockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

Ignitor Electrode · Pilot Burner · Thermocouple

Page 18 of the Desa Tech CGN10TL user manual — MANUAL LIGHTING PROCEDURE
Page 18 · click to enlarge
Page 18

TO TURN OFF GAS TO APPLIANCE OPERATING

HEATER

Shutting Off Heater 1. Turn control knob clockwise Clockwise to the OFF position.

2. Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT CONTROL OPERATION

The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO.

MANUAL LIGHTING PROCEDURE

1. Remove front panel (see Figure 10, page 12).
2. Follow steps 1 through 5 under Lighting Instructions , pages 16 and 17.
3. With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
5. Replace front panel.
Page 19 of the Desa Tech CGN10TL user manual — GRH/OV 008 BAD PILOT/LP
Page 19 · click to enlarge
Page 19

INSPECTING

Check pilot flame pattern and burner flame pattern often.

BURNER

PILOT FLAME PATTERN

Figure 17 shows a correct pilot flame pattern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

GRH/OV 009 GOOD PILOT

Figure 17 - Correct Pilot Flame Pattern

GRH/OV 008 BAD PILOT/LP

Figure 18 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 18

  • turn heater off (see To Turn Off Gas to Appliance , above)
  • see Troubleshooting , pages 21 through 24
Show 4 more labels / short text on this page
Pilot Burner · Thermocouple · Pilot Burner · Thermocouple
Page 20 of the Desa Tech CGN10TL user manual — 1/2 GLASS HEIGHT
Page 20 · click to enlarge
Page 20

INSPECTING

BURNER FLAME PATTERN Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

BURNER

1/2 GLASS HEIGHT

CORRECT FLAME PATTERN

AT HIGH POSITION

Figure 19 - Correct Burner Flame Pattern

1/2 GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

Figure 20 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 20

  • turn heater off (see To Turn Off Gas to Appliance , page 18)
  • see Troubleshooting , pages 21 through 24

Yellow Tipping

Page 21 of the Desa Tech CGN10TL user manual — OBSERVED PROBLEM
Page 21 · click to enlarge
Page 21

CLEANING

AND MAINTENANCE

ODS/PILOT AND BURNER ORIFICE

  • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

  • Air Passageways
  • Use a vacuum cleaner or pressurized air to clean. Exterior
  • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

TROUBLESHOOTING

operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor cable pinched or wet
1. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 2. Reconnect ignitor cable
2. Ignitor electrode not connected to ignitor cable 3. Piezo ignitor nut is loose
3. Tighten nut holding piezo ignitor to heater cabinet. Nut is located inside heater cabinet at top 4. Replace ignitor cable 5. Replace ignitor 6. Replace piezo ignitor 7. Replace ignitor
4. Broken ignitor cable 5. Ignitor electrode broken 6. Bad piezo ignitor 7. Ignitor electrode positioned wrong
Page 22 of the Desa Tech CGN10TL user manual — OBSERVED PROBLEM
Page 22 · click to enlarge
Page 22

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or manual shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Clean ODS/pilot (see Cleaning and Maintenance , page 21) or replace ODS/pilot assembly 6. Replace gas regulator
5. ODS/pilot is clogged
6. Gas regulator setting is not correct
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Wait one minute for safety interlock system to reset. Repeat ignition operation. 4. Fully open manual shut-off valve 5. Hand tighten until snug, then tighten 1/4 turn more 6. A) Contact local natural gas company

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
3. Safety interlock system has been triggered
4. Manual shutoff valve not fully open 5. Thermocouple connection loose at control valve 6. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 7. Thermocouple damaged 8. Control valve damaged

B) Clean ODS/pilot (see Cleaning and Maintenance, page 21) or replace ODS/pilot assembly

7. Replace thermocouple
8. Replace control valve
Page 23 of the Desa Tech CGN10TL user manual — OBSERVED PROBLEM
Page 23 · click to enlarge
Page 23

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1. Burner orifice is clogged
1. Clean burner orifice (see Cleaning and Maintenance , page 21) or replace burner orifice 2. Replace burner orifice
2. Burner orifice diameter is too small 3. Inlet gas pressure is too low
3. Contact local natural gas company

Delayed ignition of burner

1. Manifold pressure is too low 2. Burner orifice is clogged
1. Contact local natural gas company 2. Clean burner orifice (see Cleaning and Maintenance , page 21) or replace burner orifice

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner orifice (see Cleaning and Maintenance , page 21) or replace burner orifice 2. Contact local natural gas company 3. Replace burner 4. Replace gas regulator
2. Inlet gas pressure is too low 3. Burner damaged 4. Gas regulator defective

Yellow flame during burner combustion

1. Not enough air
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance , page 21) 2. Contact local natural gas company 3. Replace gas regulator
2. Inlet gas pressure is too low 3. Gas regulator defective

Slight smoke or odor during initial operation

1. Residues from manufacturing processes
1. Problem will stop after a few hours of operation

Heater produces a whistling noise when burner is lit

1. Turning control knob to HI position when burner is cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas checked by local natural gas company 3. Observe minimum installation clearances (see Figure 4, page 10) 4. Clean burner (see Cleaning and Maintenance , page 21) or replace burner orifice
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice
Page 24 of the Desa Tech CGN10TL user manual — OBSERVED PROBLEM
Page 24 · click to enlarge
Page 24

TROUBLESHOOTING

WARNING ICON G 001 WARNING

If you smell gas

  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person

Heater produces unwanted odors

1. Heater burning vapors from paint, hair spray, glues, etc. See IMPORTANT statement above. 2. Gas leak. See Warning statement at top of page
1. Ventilate room. Stop using odor-causing products while heater is running 2. Locate and correct all leaks (see Checking Gas Connections , page 14)

Heater shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure
1. Open window and/or door for ventilation 2. Contact local natural gas company 3. Clean ODS/pilot (see Cleaning and Maintenance , page 21)
3. ODS/pilot is partially clogged

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections , page 14) 2. Replace control valve

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 14)

Moisture/condensation noticed on windows

1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Ventilation requirements (page 5)
Page 25 of the Desa Tech CGN10TL user manual — HINTS
Page 25 · click to enlarge
Page 25

TECHNICAL

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

SERVICE

SPECIFICATIONS

CGN10T and CGN10TL Btu (Variable) 5,000/10,000 Type Gas Natural Only Ignition Piezo Pressure Regulator Setting 3" W.C. Inlet Gas Pressure (inches of water)

Maximum 10.5" Minimum 4" Dimensions, Inches (H x W x D)

Heater (Including knobs and grill) 21 1/2 x 13 1/2 x 7 Carton 25 1/4 x 16 3/4 x 7 1/2 Weight (pounds)

SERVICE

When gas pressure is too low

  • pilot will not stay lit
  • burner will have delayed ignition
  • heater will not produce specified heat When gas quality is bad

HINTS

  • pilot will not stay lit
  • burner will produce flames and soot
  • heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

Shipping 19

Page 26 of the Desa Tech CGN10TL user manual — TECHNICAL
Page 26 · click to enlarge
Page 26
Desa Tech CGN10TL — TECHNICAL diagram (page 26)
Fig. 1
Page 27 of the Desa Tech CGN10TL user manual — PARTS AVAILABLE - NOT SHOWN
Page 27 · click to enlarge
Page 27

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.

CGN10T CGN10TL

KEY PART NO. NUMBER DESCRIPTION QTY.

1 098304-01 Screw, #10 x 3/8" 2 2 099467-02 Front Panel Assembly,

Earthtone (CGN10T) 1 099467-05 Front Panel Assembly,

Ivory (CGN10TL) 1 3 099318-04 Grill Guard 1 4 101108-01 Grill Guard Clip 2 5 102018-01AA Bottom Glass Retainer 1 6 098260-03 Glass Panel 1 7 098532-03AA Top Glass Retainer 1 8 M11084-38 Screw, #8 x 3/8" 8 9 098352-03BR Deflector Unit 1 10 098271-03 Ignitor Cable 1 11 098249-01 Nut, M5 2 12 100701-03 ODS/Pilot Assembly 1 12-1 098514-01 Thermocouple 1 12-2 098594-01 Ignitor Electrode 1 13 099386-02 Burner 1 14 099387-11 Pilot Tubing 1 15 098251-03 Injector 1 16 099463-01 Injector Holder 1 17 099415-01 Pressure Regulator 1 18 102863-01 Burner Tubing 1 19 102864-01 Regulator Tubing 1 20 102492-01 5/16" Male Connector 1 21 102493-01 1/4" Male Connector 1 22 098522-07 Thermostat Gas Valve 1 23 102571-01 Cabinet Assembly, Brown (CGN10T) 1 102571-03 Cabinet Assembly, Ivory (CGN10TL) 1 24 102445-01 Piezo Ignitor 1 25 098275-01 3/8" NPT Male Plug 2 26 099553-01 Pilot Shield 1 27 098303-02 Screw, #6 x 5/16" 2

PARTS AVAILABLE - NOT SHOWN

102471-01 Control Position Label 1 100642-02 Assembly, Hardware 1

Page 28 of the Desa Tech CGN10TL user manual — SERVICE PUBLICATIONS
Page 28 · click to enlarge
Page 28

REPLACEMENT

PARTS

Parts Under Warranty Contact authorized dealer from whom you purchased this product. If they cannot supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-323-5190 for referral information.

When contacting your dealer or DESA International, have ready:

  • your name
  • your address
  • model number of your heater
  • how heater was malfunctioning
  • type of gas used (propane or natural gas)
  • purchase date Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty Contact authorized dealers of this product. If they cannot supply original replace- ment part(s), either contact your nearest Parts Central (see page 29) or call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready:

  • model number of your heater
  • the replacement part number

SERVICE PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

ACCESSORY Purchase these heater accessories from your local dealer. If they cannot supply this accessories, either contact your nearest Parts Central (see page 29) or call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the address listed on the back page of this manual.

MANUAL SHUTOFF VALVE - GA5010 Manual shutoff valve with 1/8" NPT tap.

Page 29 of the Desa Tech CGN10TL user manual — PARTS CENTRAL
Page 29 · click to enlarge
Page 29

PARTS CENTRAL

These Parts Centrals are privately-owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911 Parts Department

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426 Parts Department

Portable Heater Parts 342 N. County Rd. 400 E. Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951 Parts Department

East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809 Parts Department

Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 610-430-7717 1-800-368-0803 Parts Department

FBD 1349 Adams St. Bowling Green, KY 42103 502-846-1199 1-800-654-8534

Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724 Parts Department

LaPorte’s Parts and Service 2444 North 5th Street Hartsville, SC 29550 803-332-0191 Parts Department

Four Flags Power Products 1115 Stateline Road Niles, MI 49120 616-684-2697 Parts Only

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301 Parts Department

Albany Ladder 1586-90 Central Avenue Albany, NY 07728 NY, MA, VT 518-869-5335 1-800-354-7368 (NY, MA, VT) Parts Department

Master Parts Distributor 1184 Wilson Ave. NW Grand Rapids , MI 49504 616-791-0505 1-800-446-1446 Fax: 1-616-791-8270 Parts Department

Page 30 of the Desa Tech CGN10TL user manual — NOTES _________________________________________________________________
Page 30 · click to enlarge
Page 30

NOTES

Show 38 more labels / short text on this page
_________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________
Page 31 of the Desa Tech CGN10TL user manual — NOTES _________________________________________________________________
Page 31 · click to enlarge
Page 31

NOTES

Show 38 more labels / short text on this page
_________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________
Page 32 of the Desa Tech CGN10TL user manual — 103574-01 REV. A 3/97
Page 32 · click to enlarge
Page 32

WARRANTY INFORMATION

KEEP THIS WARRANTY

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRAN- TIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004

103574-01 REV. A 3/97

Model · Date Purchased

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
2 p.2
2 p.2
22 p.22
22 p.22
24 p.24
24 p.24
28 p.28
28 p.28

Ask about the Desa Tech CGN10TL

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech CGN10TL

Be the first to ask — other owners or our team will answer.

Original document

Desa Tech CGN10TL manual PDF

32 pages·256 KB·Indoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…