OWNER'S OPERATION AND INSTALLATION MANUAL
Smooth Face
Shown with optional cabinet mantel and hearth base.
m Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
installation and operational pro- cedures. For assistance or addi- tional information consult aquali- fied installer, service agency, or the gas supplier.
approved by I.A.S. under their REQ. 2-97 for use with any ANS Z21.11.2 approved gas logs.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
This firebox may be Installed In an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. * Aftermarkct: Completion of sale, not for purpose of resale, from the manufacturer (I.e. Installation of this product Is permitted after the manufactured (mob,e) home I$ altad).
Save this manual for future reference.


Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas CodeANSZ223.1, also known as NFPA 54". Firebox must be electrically grounded in accordance with the NationalElectricalCode, ANS/NFPA 70 (latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269
With utility knife, cut the carton all the way around above the staples on the bottom tray. Lift the carton off the fire- box. Remove packing.
A am, WARNING: Any change to this firebox or its controls can be dangerous.
bum paper or other objects.
Carefully supervise young children when they are in the room with fire- box.
Turn firebox off and let cool before servicing. Only a qualified service per- son should service and repair firebox.
ing fireplace.
Operating unvented heaters (logsets) above elevations of 4,500 feet could cause pilot outage. Do not use the firebox if it has been under water due to the shock hazard that could result with the blower acces- sary (if installed) in place.
wool. Using these added items can cause sooting. 16.
2 103s73


PRODUCT FEATURES
Standoffs (Model CGFB32NC only)
This firebox is designed to accept unvented decorative gas logs. It requires no outside venting or chimney making installation easy and inexpensive. When used without the blower (model CGFB32C only), the firebox requires no electricity making it ideal for emergency backup heat.
The CGFB32C firebox wilt accept the GA3750 accessory. The variable blower allows you to select the fan speed you de- sire. The blower circulates heated air from the firebox into the room. Use of blower is optional.
Louvers (Model CGFB32C only)
Figure 1 - Firebox Front View
Standoffs (Model CGFB32NC only)
jq 22 1/2" .I
19 1/4" 1: 1
31 5/8° 343/8" 355/8"
Electrical Electrical Access Hole Access Hole
Figure 2 - Firebox Side View
Figure 3 - Firebox Top View


Confined and Unconfined Space
The National Fuel Gas Code (ANS Z2123.1,
The following _re excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.
1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
Plan where you will install the firebox. This will save time and money later when you install the firebox. Before installation, con- sider the following:
All spaces in homes fall into one of the three following ventilation classifications:
The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
This firebox shall not be installed in a con-
fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.
Unusually tight construction is defined as construction where: a. walls and ceilings exposed to
the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6x10"11kg per pa-sec-m=) or less with openings gasketed or sealed and b. weather stripping has been
not be installed ina confined space or unusually tight construction unless provisions are provided foradequate combustion and ven- tilation air. Reed the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.
added on opeaable windows and doors and c. caulldng or sealants are applied
to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tionsfor plumbing,electrical,and gas lines, and at other openings.
Today's homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss inhomes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 6.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air most enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.
If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Fireplace Location, page 5.
Exhaust fans, fireboxes, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.
Unusually Tight Construction · 4 103573


Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install firebox plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
Length x Width x Height = cu. ft. (volume of space)
Example:Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
(volume of space) + 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example: 3168 cu. ft. (volume of space) .'-50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support)
Vented gas heater Btu/Hr Vent-free firebox with log heater + 39,000 Btu/Hr
Gas firebox logs Btu/Hr Total 79,000 Btu/Hr
Other gas appliances* + Btu/Hr Total = Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Btu/l-lr (maximum the space can support)
Btu/Hr (actual amount of Btu/Hr used)
79,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. Yon must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr fireplace, if lower Btu/I-Ir size makes room unconfined.
"If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
I _lb WARNING: If the area In which the firebox end gas log heater may be operated is smeller than that defined as I an unconfined space or If the building Is of unusually tight construction, provide adequate combustion and I ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3 or eppllceble local codes.
f_ 5


Grills Ventilation Grills Into Adjoining Into Adjoining Room, Room, Option 2 Option 1
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1and 2, Figure 4). You can also remove door into adjoining room (see op- tion 3, Figure 4), Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 4 - Ventilation Air from Inside Building
sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances In both spaces.
Provide extra fresh air by using ventilation
grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces
include attics and crawl spaces.
Figure 5 - Ventilation Air from Outdoors


Note: Your Comfort Glow firebox is de- signed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your firebox, except where standoff spacers are integrally at- tached. If standoff spacers are attached to your firebox, these spacers can be placed directly against wall or framing materials.
Mantel Clearances for Conventional Installation
nation with unvented Iogsets are intended for use as supplemen- tal heat. Do not Install them as your primary heat source. If you have a central heating system, you may run system's circulat- ing blower while using unrented logs. This will help circulate the heat throughout the house. In the event of a power outage, you can use unrented logs as your pri- mary heat source.
MINIMUM CLEARANCE 42" Side Wall - 16 " Ceiling - 42" Floor - 0"
Use the dimensions shown for rough open- ings to create the easiest installation (see Built-In Firebox Installation, page 10).
16" Face or Cabinet
Mantel Floor - 0"
mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.
Figure 6 -Minimum Clearance to Walland Ceiling
Mantel Clearances for Built-In Installation
Carefully follow the instructions below. This
will ensure safe installation.
If placing custom mantel above built-in firebox, you must meet minimum clearance between mantel shelf and top of firebox opening.
Minimum Wall and Ceiling Clearances (see Figure 6) A. Clearances from the side of the fire- box opening to any combustible wall should not be less than 16 inches for a cabinet mantel or 12 inches for a cor- ner installation.
opening to bottom of mantel shelf. All measurements ate in ibches
B.
Clearances from the top of the firebox opening to the ceiling should not be less than 42 inches.
Facing material (above firebox) may be of combustible matedal. includingdecorative
heat to wall surfaces next to fire- box. Installing firebox next to vl- nyl or cloth wall coverings or operating firebox where impuri- ties In the air (such as tobacco smoke, aromatic candles, clean- Ing fluids, oil or kerosene lamps, etc.) exist, may discolor walls.
When the firebox is installed directly on carpeting, or other combustible ma- terial, other than wood flooring, the firebox should be installed on a metal or wood panel extending the full width and depth of the enclosure.
mantel orname_lts.
installing firebox in rooms without enough ventilation air may cause mildew to form fromtoomuch moisture. SeeAirfor Combus- tion and Ventilation, pages 4 through 6.
Figure 7 - Minimum Mantel Clearances for Built-In Installation
If your installation does not meet the above minimum clearances, you must:


Built-In Installation of Blower
INSTALLATION Continued
_]k CAUTION: Do not pick up log base assembly by burners, This could damage burners. Only handle base by grates.
You may install blower accessory GA3750 with conventional installation (below) or with built-in installation (page 10) with model CGFB32C only. To install blower accessory, see instruction sheet included with the kit.
metal data plates attached to the heater base assembly. The data plates contain Important warranty Information.
to duplex outlet. Match wire colors to those indicated on duplex outlet. Be sure to connect ground wire.
screws.
Figure 9 - Routing Blower Accessory Power Cord for Built-In Installation
Figure 10- Removing Firebox Bottom
Figure 8 - Routing Blower Accessory Power Cord for Conventional Installation


Attach flexible gas line to log set. See Connecting to Gas Supply in your log set owner's manual.
If installing GA3750 blower (CGFB32C firebox only), route blower electrical cord through bushing in right side fire-
box support and bushing in side access opening of firebox. Plug electrical cord
into electrical outlet. See Installing Blower Accessory, page 8.
screw.
Place hearth base accessory against wall at installation location. Cut an access hole in hearth top to run flexible gas line
to firebox (see Figure 13). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over.
Figure 12- Installing Fireplace Screen
Route flexibie gas line through access hole in hearth base.
Center cabinet mantel on hearth base
(see Figure 14). Make sure mantel is flush against wall.
Figure 14 - Installing'Cabinet Mantel
This firebox may be installed using the cabi- 7. net mantel andhearthbase accessories against a wall in your home. Follow the instructions 8. below m install the firebox in this manner.
Break off nailing flanges (see Figure
Place cardboard or other protective material on top of hearth base. Care- fully set firebox on protective material,
with back of firebox inside mantei opening.
Electrical FlexibleGas Line Outlet
is optional for this installation. You can install firebox and cabinet mantel directly on the floor.
HearthBase _ / Gas _ .j/ Line Access
Figure 15- Location of Nailing Flanges
Figure 13 - Placing Hearth Base Accessory Against Wall


Carefully set firebox in front of rough opening with back of firebox inside wall opening. IMPORTAIVT: If installing Brass Trim Kit GA7090, see instructions included with brass trim accessory. You must install shoulder screws now.
If using GA3750 blower accessory (Model CGFB32C only), see Installing Built-In Installation of Blower Acces- sory, page 8.
flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item
Attach flexible gas line to log set. See Connecting to Gas Supply in log set owner's manual.
installed on thegas piping. See Connect- ing to Gas Supply in log set owner's manual.
Carefully insert firebox into rough opening.
Attach firebox to wall studs using nails or wood screws through holes in nail- ing flange (see Figure 19).
Check all gas connections for leaks. See Checking Gas Connections in log set owner's manual.
If using optional GA7090 brass trim kit, install the trim after final finishing and/ or painting of wall. See iusttuctions in-
cluded with brass trim accessory for at- taching brass trim.
Figure 16- Inserting Firebox Into Cabinet Mantel
Nails or Wood Screws
Figure 17- Rough Opening for Installing In Waft
Built-in installation of this firebox involves installing firebox into a framed-in enclosure. This makes the front of firebox flush with wall. Optional brass trim (GA7090) is avail- able (see Accessories, page 11) This brass trim will extend past sides of firebox ap- proximately 1/2 inch. This will cover rough edges of the wall opening. If installing a mantel above the firebox, but you must fol- low the clearances shown in Figure 7, page 7. Follow the instructions below to install the fvebox in this manner.
Figure 18- Rough Opening for Installing In Corner
Figure 19 - Attaching Firebox to Well Studs
Height Front Width Depth
Model # Actual Framing Actual Framing Actual Framing
CGFB32C 323/s" 33" 34s/16" 343/4 .. 1611/16" 173/4"
CGFB32NC 3311hs" 34V4" 34s/18" 34314" 1611h8" 178/4"


ACCESSORIES
Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International's Sales Department at 1-800-432-2382 for information. You can also write to the ad- dress listed on the back page of this manual.
You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International's Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
PARTS
CABINET MANTEL WITH PERIMETER BRASS TRIM GMC11F Series - Walnut Finished GMC13F Series - Oak Finished GMC12U Series - Unfinished
MANUAL SHUTOFF VALVE - GA5010 For all models. Manual shutoff valve with
Contact authorized dealers of this product or
1/8" NPT tap. Fits liT' NPT pipe.
Parts Central (see page 15). If they can't supply original replacement part(s),call DESA International's Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
Mantel features moldings, fluted sides and medallion. Available in walnut finished or unfinished hardwood, ready to stain or paint. Shown with optional base accessory. Approximate Dimensions (HxWxD): 44" x 57 3/4"X22 7Is''
When calling DESA International, have ready
your name your address model number of your fireplace
how fireplace was malfunctioning type of gas used (propane or natural gas)
Use with Model CGFB32C only. The vari- able blower allows you to select the desired speed. The blower circulates heated air from the fireplace into the room.
Usually, we will ask you to return the defec- tive part to the factory.
Contact authorized dealers of this product or Parts Central (see page 15). If they can't
HEARTH BASE - Use with Cabinet Mantel GC3333F- Walnut Finished GC3335F Series - Oak Finished GC3334U - Unfinished
supply original replacement part(s), call DESA International's Parts Department at 1-800-972-7879 for referral information.
CORNER MANTEL WITH PERIMETER BRASS TRIM GMC36F Series - Walnut Finished GMC37U Series - Unfinished
When calling DESA International, have ready • model number of your fireplace
The hearth base creates a handsome riser for the fireplace. Approximate Dimensions (HxWxD): 6 Ih" x 58" x 289/16"
Ideal for space saving installations. Approximate Dimensions (WxHxD): 60 7/8"x 48 3IV'x 34 _/8''
the replacement part number
GA7090 (Not Shown) Required with all mantel accessories. Op- tional with built-in installation. Provides a finished appearance covering rough and/or unfinished mantel edges.
purchase date · 1_ 11


I I I I I I
_.j
j"_ · J i <- · 10-2 •


This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.
CGFB32NC PART NUMBER DESCRIPTION
KEY NO.
QTY.
1 2 3 4 5 6 7
Firebox Top 1 Firebrick Retainer 3 Rear Firebrick 1 Side Firebrick 2
Outer Casing 1 Outer Shell Base 1
8 9 10 10-1 10-2 10-3 10-4 10-5 11 12 13 14 15 15 17 15
Assembly Screen 2 Shoulder Screw 2
Front Assembly Hood, Louvered, Painted 1 Side, Left, Painted 1 Panel, Front Lower, Painted 1
103411-02CK 103205-01CK 103211-02CK 103206-01CK Ml1084-26 103250-01CK 103809-01 10381_01
Side, Right, Painted 1 Screw, HWH AB t0-16 8 Firebox Bottom 1 Screen Rod 2 Firebox Insulation 1
101348-01 101357-03 Ml1084-26 098194-02 098304-01
Outer Casing Top 1 Hex Head Screw, #10-16 49 Stand Off 3
Phillips Pan Head Screw, #10 13
**Not Available as an Assembly
Firebox Wrapper 1 · Firebox Support 2 · 1o3s_ 13


14 _o5573


This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page l l of this manual.
KEY NO.
QTY.
101872-03 101889-01 101929-03 101932-03 103207-01
Firebox Top 1 Firebrick Retainer 3 Rear Firebrick 1
5 6 7 8 9 10 10-1 10-2 10-3 10-4 10-5 11 12 13
Outer Casing 1 Outer She, Base 1
Firebox Wrapper 1 Assembly Screen 2 Screw, Outlet Mounting 1 Front Assembly Hood, Louvered, Painted 1
Side, Left, Painted 1 Panel, Front Lower, Painted 1
103206-01CK M 11084-26 103250-01CK 103809-01 101348-01 101357-01 Ml1084-26
Side, Right, Painted 1 Screw, HWH AB 10-16 8 Firebox Bottom 1 Screen Rod 2
Firebox Support 2 Outer Casing Top 1 Hex Head Screw, #10-16 49
14 15 16 17 18 19
103771-01 098304-01 103769-01 099230-02
Strain Relief Fitting 1 Phillips Pan Head Screw, #10 13 Duplex Outlet 1 Shoulder Screw 2
**Not Availableas an Assembly
These Parts Centrals are privately-owned businesses. They have agreed to support our customer's needs by providing original replacement parts and accessories.
Four Flags Power Products East Coast Energy Products Halco Enterprlsas 1115 Stateline Road 707 Broadway 208 Carter'Drive, Unit 21 Niles, M149120 W. Long Branch, NJ 07764 West Chester, PA 19382-4500 616-684-2697 732-870-8809 610-430-7717 1-800-268-4983 1-800-755-8809 1-800-368-0803 Parts Only Parts Department Parts Department
1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department
Portable Heater Parts 342 N. County Rd. 400 E. Valparaiso, IN 46383 All States "219-462-7441
Master Parts Distributor 1251 Mound Ave. NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 1-616-791-8270 Parts Department
Tarentln Tank Co.
LaPorte's Parts and Service 2444 North 5th Street Hartsville, SC 29550-7704 803-332-0191 Parts Depadment
P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724 Parts Department
Cans Unllmtted, Inc. P.O. Box645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301 Parts Department
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426 Parts Department
FBD "1349 Adams St.
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 Parts Department
BowlingGreen, KY 42103 502-846-1199 1-800-654-8534 Fax: 1-800-846-0090
Heater and Fireplace Store
1922 N. Route 9 Cape May Court, NJ08210-1110 609-624-0678 Parts Department


Serial No.
COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERS
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with
all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who wilt provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPO- NENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL'S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSE- QUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 illWlU
103573 01 NOT A UPC
103573-01 REV. D 01/99
Model · Date Purchased
Owners and our team usually reply within a day — and your question helps the next person too.