where not prohibited by state or local codes. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer OWNER’S OPERATION AND INSTALLATION MANUAL
AND CGF280NT
Shown with optional cabinet mantel and hearth base.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
Save this manual for future reference.
®


WARNING ICON G 001 WARNINGS Continued



LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.
*Available from: American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
UNPACKING 1. Place the carton containing the fireplace unit on its back. Hold fireplace and pull the carton and pallet away. Remove trim kit from front of fireplace. 2. Locate two screws above top corners of the fireplace screen. Remove and discard these screws. Lift fireplace screen up and pull out to remove. 3. Remove protective packaging applied to logs, log base assembly, and fireplace. 4. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought fireplace.
Operation This vent-free fireplace is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing embers. The fireplace requires no electricity making it ideal for emergency back-up heat.
Safety Features This fireplace has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS system protects against oxygen depletion and any interruption in the fuel supply. If either occurs, the ODS shuts off gas flow to the burner, turning the fireplace off. An internal regulator controls fluctuations in your gas pressure.
Piezo Ignition System This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace.
Thermostat Control (CGF280NT) These fireplaces have a thermostat sensing bulb and a control valve. The thermo- stat controls the heat output and flame height. This maintains a consistent room temperature. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher comfort settings allows the fireplace to run longer, producing greater heat output. At lower comfort settings, the fireplace will run less. This results in increased heating comfort. This can also result in lower gas bills.
Variable Manual Control (CGF265NVA) These fireplaces have a variable manual control valve which allows the user to choose the heat setting that best suits his needs. Any setting between low and high may be selected by simply turning the control knob.

WARNING ICON G 001 WARNING
This heater shall not be installed in a confined space unless provi- sions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space. The information on pages 6 through 8 will help you classify your space and provide adequate ventilation. Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continu-
ous water vapor retarder with a rating of one perm or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window
and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide addi- tional fresh air. See Ventilation Air From Outdoors, page 7. If your home does not meet all of the three criteria above, proceed to page 6.
Unconfined Space The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines uncon- fined space as having a minimum air volume of 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms. Confined Space The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines confined space as having an air volume of less than 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms.

Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
Length x Width x Height = cu. ft. (volume of space) Example: Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example: 3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum
Btu/Hr the space can support)
Vent-free fireplace Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr
Example: Gas water heater 40,000 Btu/Hr Vent-free fireplace + 28,000 Btu/Hr Total = 68,000 Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework work sheet, adding the space of an adjoining room. If the extra space pro-
vides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 8. B. Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 8. C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 3). You can also remove door into adjoining room (see option 3, Figure 3). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Ventilation Grills Into Adjoining Room,
Or Remove Door into Adjoining
Figure 3 - Ventilation Air from Inside Building
Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.
Inlet Air Ventilated Crawl Space
Figure 4 - Ventilation Air from Outdoors

A qualified service person must install fireplace. Follow all local codes.
CHECK GAS TYPE Use only natural gas. If your gas supply is not natural gas, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

ASSEMBLING AND ATTACHING BRASS TRIM Note: The instructions below show assembling and attaching brass trim to fireplace. Do not yet install trim if performing a built-in installation (see page 14, Built- In Fireplace Installation) 1. Remove packaging from three pieces of brass trim. 2. Locate four brass screws, two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 5. 4. Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 5). 5. Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 5). 6. While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver. 7. Repeat steps 1 through 6 for other side.
Set Screws Adjusting Plate
Side Brass Trim Top Brass Trim
Figure 5 - Assembling Brass Trim
Hanging Notches on Trim
Figure 6 - Attaching Brass Trim to Fireplace

Carefully follow the instructions below. This will ensure safe installation. Minimum Wall and Ceiling Clearances (see Figure 7) A. Clearances from the side of the fireplace opening to any combustible wall should
not be less than 16 inches for a cabinet mantel or 12 inches for a corner installation. B. Clearances from the top of the fireplace opening to the ceiling should not be
less than 42 inches.
MINIMUM CLEARANCE Side Wall - 16 " Ceiling - 42" Floor - 0"
Figure 7 - Minimum Clearance to Wall and Ceiling
CONVENTIONAL FIREPLACE INSTALLATION Conventional installation of this fireplace involves installing fireplace along with the cabinet mantel and hearth base accessory against a wall in your home. Follow the instructions below to install the fireplace in this manner.
42" · 16"

2. Break off nailing flanges (see Figure 8) with hammer or pliers. 3. Place mantel and base in desired location. Place heater in front opening of mantel. Make sure all pieces fit properly. Remove mantel. 4. Mark floor and base or wall for gas line entrance. Make sure there is enough clearance between heater and mantel for gas line. IMPORTANT: Make sure there are no electrical lines where gas piping will go through floor or wall. 5. Cut an access hole in hearth base top to run flexible gas line to fireplace (see Figure 9). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over.
Figure 8 - Location of Nailing Flanges
Electrical Outlet Hearth Base Flexible Gas Line
Gas Line Access Hole
Figure 9 - Placing Hearth Base Accessory Against Wall
Nailing Flanges

Figure 10 - Installing Cabinet Mantel
7. Carefully place fireplace on top of hearth base (Figure 11). Be careful not to scratch or damage hearth base. Note: You can secure fireplace to hearth or floor. Open lower louver. Locate screw holes in bottom of base. Secure with wood screws through these holes and into hearth or floor. 8. Connect fireplace to gas supply (see page 17). 9. Check all gas connections for leaks. See Checking Gas Connections, page 18. 10. After heater is secured, replace mantel on hearth base (see Figure 10). Make sure mantel is flush against wall. Install brass trim (see page 10).
Figure 11 - Inserting Fireplace Into Cabinet Mantel
Cabinet Mantel

BUILT-IN FIREPLACE INSTALLATION Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, but you must follow the clearances shown in Figure 15, page 15. Follow the instructions below to install the fireplace in this manner.
Height Front Width Depth
Actual Framing Actual Framing Actual Framing
32 3/8" 33" 34 5/16" 35 1/2" 16 11/16" 17 3/4"
33"
35 1/2"
Figure 12 - Rough Opening for Installing in Wall
If installing in a corner, use dimensions shown in Figure 13 for the rough opening. The height is 33" which is the same as the wall opening above.
39 3/8" 27 7/8"
55 5/8" 35 1/2"
Figure 13 - Rough Opening for Installing in Corner
2. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, page 16. 3. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening. 4. Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 17. 5. Carefully insert fireplace into rough opening. 6. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 14). 7. Check all gas connections for leaks. See Checking Gas Connections, page 18. 8. Install brass trim after final finishing and/or painting of wall (see Figure 6, page 10).


Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.
20" 241/2" 271/2" 30"
Figure 15 - Minimum Mantel Clearances for Built-In Installation

NOTICE
A qualified service person must connect fireplace to gas supply. Follow all local codes.
Installation Items Needed Before installing fireplace, make sure you have the items listed below.
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 38.
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 16, page 17).
Check your building codes for any special requirements for locating manual shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
Install sediment trap in supply line as shown in Figure 16, page 17. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap*
Approved Flexible Gas Line
From Gas Meter (5" W.C. to 10.5" W.C.
Figure 16 - Gas Connection
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 38.
Figure 17 - Removing Log Base Assembly From Fireplace

5. Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line (see Figure 18). Connect flexible gas line to flexible gas line attached to gas regulator of fireplace (see Figure 18). 6. Check all gas connections for leaks. See Checking Gas Connections, below. 7. Replace log base assembly back into fireplace. Feed flexible gas line into fireplace base area while replacing log base assembly. Make sure the entire flexible gas line is in fireplace base area. Reattach log base assembly to fire- place with screws removed in step 3.
To Fireplace Gas Regulator Gas Connector
Flexible Gas Line from Fireplace Gas Regulator
Flexible Gas Line from Manual Shutoff Valve
Figure 18 - Attaching Flexible Gas Lines Together
Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG 1. Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace gas regula- tor. 2. Cap off open end of gas pipe where manual shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Re-connect fireplace and manual shutoff valve to gas supply. Check re-con- nected fittings for leaks.
Manual Shutoff Valve · To Gas Meter

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 19). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to manual shutoff valve (see Figure 20). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Pressure Testing Fireplace Gas Connections 1. Open manual shutoff valve (see Figure 19). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from manual shutoff valve to thermostat gas valve (see Figure 20). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light fireplace (see Operating Fireplace, pages 21 through 23 [Thermostat- controlled models] or pages 23 through 25 [Manually-controlled models]). Check all other internal joints for leaks. 7. Turn off fireplace (see To Turn Off Gas to Appliance, page 23 [Thermostat- controlled models] or page 25 [Manually-controlled models]).
OFF POSITION
Figure 19 - Manual Shutoff Valve
Figure 20 - Checking Gas Joints

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Slide front log (#1) into place behind front burner. Make sure tabs at bottom of log are behind front burner (see Figure 21). 2 . Slide rear log (#2) into place behind rear burner (see Figure 22). 3. Place left front branch (#4) and right front branch (#5) (24" and 30" models) or front branch (#4) (18" model) into place (see Figure 23). Make sure notches on bottom rest on grates.
Figure 21 - Installing Front Log
Figure 22 - Installing Rear Log
Figure 23 - Installing Rear Log

Notches Screws for Mounting Screen Figure 24 - Installing Fireplace Screen
FIREPLACE
CGF280NT
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS

FIREPLACE
NOTICE
During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.
Figure 25 - Control Knob and Ignitor Button Location
Note: If running fireplace for first time, there will be air in gas line. You may need to press in control knob for 30 seconds or longer. This will allow air to bleed from the gas system. 6. Continue pressing control knob in. Press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Figure 26 - Pilot

Shutting Off Fireplace Turn control knob clockwise Clockwise to the OFF position.
Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise Clockwise to the PILOT position.
You can set the thermostat control knob to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
FIREPLACE Manually-Controlled
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS

FIREPLACE Manually-Controlled
NOTICE
During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.
Figure 27 - Control Knob and Ignitor Button Location
Note: If running fireplace for first time, there will be air in gas line. You may need to press in control knob for 30 seconds or longer. This will allow air to bleed from the gas system. 6. Continue pressing control knob in. Press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.
Figure 28 - Pilot

FIREPLACE Manually-Controlled
The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher settings produces greater heat output. This results in increased heating comfort.
WARNING ICON G 001 WARNING
Do not operate heater between pilot and high positions.
Do not try to adjust heating levels by using the manual shutoff valve.
Shutting Off Fireplace 1. Turn control knob clockwise Clockwise to the HIGH position. 2. Slightly depress control knob and turn clockwise Clockwise to the PILOT position. 3. Slightly depress control knob and turn clockwise Clockwise to the OFF position.
Shutting Off Burners Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the HIGH position. 2. Press in and turn clockwise Clockwise to the PILOT position.

Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN Figure 29 shows a correct pilot flame pattern. Figure 30 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.
Figure 29 - Correct Pilot
Figure 30 - Incorrect Pilot
Flame Pattern If pilot flame pattern is incorrect, as shown in Figure 29
Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by fireplace, causing brief patches of orange flame.
Figure 31 - Correct Front Burner Flame Pattern
Yellow Tipping At Top of Blue Flame
Figure 32 - Incorrect Front Burner Flame Pattern
If front burner flame pattern is incorrect, as shown in Figure 32
Thermocouple Pilot Burner · Pilot Burner Thermocouple · Flame Pattern

operation.
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see Cleaning and Mainte- nance, page 27) or replace ODS/pilot assembly

OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit
POSSIBLE CAUSE 1. Burner orifice(s) clogged
REMEDY 1. Clean burner(s) (see Cleaning and Mainte- nance, page 27) or replace burner orifice(s) 2. Replace burner orifice(s)
Delayed ignition of one or both burners
Burner backfiring during combustion
Yellow flame in front burner during burner combustion
Slight smoke or odor during initial operation
Fireplace produces a whistling noise when burners are lit
Moisture/condensation noticed on windows

WARNING ICON G 001 WARNING If you smell gas
POSSIBLE CAUSE
REMEDY
Fireplace produces a clicking/ticking noise just after burners are lit or shut off
Fireplace produces unwanted odors
Fireplace shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Moisture/condensation noticed on windows

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.
BTU (Variable) 20,000/28,000 Type Gas Natural Gas Only Ignition Piezo Manifold Pressure 3.4" W.C. Inlet Gas Pressure (in. of water)
Maximum 10.5" Minimum* 5" (*For purpose of input adjustment) Shipping Weight 80 lbs.
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564). TECHNICAL
PARTS CENTRALS
These Parts Centrals are privately-owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911 Parts Department
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426 Parts Department
Portable Heater Parts 342 N. County Rd. 400 E. Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951 Parts Department
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809 Parts Department
Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 610-430-7717 1-800-368-0803 Parts Department
Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724 Parts Department
FBD P.O. Box 1096 1720 Kummer Road Franklin, KY 42134 502-586-1922 1-800-654-8534
LaPorte’s Parts and Service 2444 North 5th Street Hartsville, SC 29550 803-332-0191 Parts Department
Albany Ladder 1586-90 Central Avenue Albany, NY 07728 NY, MA, VT 518-869-5335 1-800-354-7368 (NY, MA, VT) Parts Department
Four Flags Power Products 1115 Stateline Road Niles, MI 49120 616-684-2697 Parts Only
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301 Parts Department
Master Parts Distributor 1184 Wilson Ave. NW Grand Rapids , MI 49504 616-791-0505 1-800-446-1446 Fax: 1-616-791-8270 Parts Department



This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.
CGF265NVA
KEY NO. PART NUMBER DESCRIPTION QTY.
1 102230-02 Front Log (#1) 1 2 102231-02 Rear Log (#2) 1 3 102568-01 Control Valve 1 4 101332-01 Left Front Branch (#4) 1 5 101333-01 Right Front Branch (#5) 1 6 098304-01 Screw, #10 Phillips, Black 8 7 100701-02 O.D.S. Pilot 1 7-1 098594-01 Ignitor 1 7-2 098593-01 Thermocouple 1 8 098249-01 Nut 6 9 101006-01 Pilot Bracket 1 10 101330-05 Front Burner 1 11 100999-05 Rear Burner Assembly 1 12 102256-04BR Base Assembly 1 13 098271-06 Ignitor Cable 1 14 101924-01CB Firebox Bottom 1 15 098867-09 Gas Regulator 1 16 101004-04 Front Burner Injector 1 17 097159-02 Piezo Ignitor 1 18 101007-01 Crossover Tube 1 19 099387-05 Pilot Tube 1 20 101972-01 Valve and Piezo Bracket 1 21 M11084-38 Regulator Hex Screw 2 22 102668-01 Front Burner Tube 1 23 101008-01 Gasket 1 24 101973-01 Inlet Tube 1 25 098276-01 1/8" Plug 1 26 101004-11 Rear Burner Injector 1 27 M11084-26 Hex Screw, #10 2 28 098508-01 Valve Retainer Nut 1 29 101628-01 Flex Hose 1 30 097809-02 Adapter 1 31 098354-01 Control Knob 1
100563-01 Warning Plate 1 101055-02 Lighting Instructions Plate 1 100565-01 Warning Plate Fastener 1 101416-14 Information Video 1 101976-02 Control Position Decal 1



This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.
Controlled
Models
CGF280NT
KEY NO. PART NUMBER DESCRIPTION QTY.
1 102230-02 Front Log (#1) 1 2 102231-02 Rear Log (#2) 1 3 11084-38 Screw 2 4 101332-01 Left Front Branch (#4) 1 5 101333-01 Right Front Branch (#5) 1 6 098304-01 Screw, #10 Phillips, Black 8 7 100701-02 O.D.S. Pilot 1 7-1 098594-01 Ignitor 1 7-2 098593-01 Thermocouple 1 8 098249-01 Nut 4 9 101006-01 Pilot Bracket 1 10 101330-05 Front Burner Assembly 1 11 100999-02 Rear Burner Assembly 1 12 102256-04BR Base Assembly 1 13 098271-06 Ignitor Cable 1 14 101924-01CB Firebox Bottom 1 15 098867-09 Gas Regulator 1 16 101004-04 Front Burner Injector 1 17 102845-01 Inlet Tube 1 18 101382-01 Thermovalve Bracket 1 19 099387-03 Pilot Tube 1 20 102846-01 Burner Tube 1 21 097809-02 Adapter 1 22 099211-01 Screw 2 23 098544-01 Thermostat Clamp 1 24 101329-16 Thermostat Gas Valve Assembly 1 25 101381-01 Cover and Piezo 1 26 101004-01 Rear Burner Injector 1 27 M11084-26 Hex Screw, #10 2 28 101628-01 Flex Hose 1
100563-01 Warning Plate 1 101054-01 Lighting Instructions Plate 1 100565-01 Warning Plate Fastener 1 101416-14 Information Video 1



This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.
CGF280NT CGF265NVA
KEY NO. PART NUMBER DESCRIPTION QTY.
1 101357-01 Top Outer Casing 1 2 101373-01 Outer Casing 1 3 102923-01CB Right Front Side 1 4 102922-01CB Left Front Side 1 5 101368-01 Access Door 2 6 101352-01CB Top Front 2 7 101739-01CB Louver Hood 1 8 101375-04BR Firebox Wrapper 1 9 101738-01CB Lower Louver Assembly 1 10 101367-02BR Screen Assembly 1 11 101348-01 Firebox Support 2 12 101347-01CB Outer Base 1 13 099230-02 Shoulder Screw 4 14 098304-01 Phillips Pan Head Screw, #10 9 15 101872-03 Firebox Top 1 16 M11084-26 Hex Screw, #10 63 17 101746-01 Handle 1 18 100587-01 Brass Screw, #6-20x3/8" 3 19 101784-01 Snap-in Magnet 2
102753-01 Brass Trim Kit 1 100639-01 Caution Decal 1 102865-01 Brass Trim Hardware 1

Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replace- ment part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
When calling DESA International, have ready
Parts Not Under Warranty Contact authorized dealers of this product or Parts Central (see page 31). If they can’t supply original replacement part(s), call DESA International’s Parts Depart- ment at 1-800-972-7879 for referral information.
When calling DESA International, have ready
Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382 for information. You can also write to the address listed on the back page of this manual.
CABINET MANTEL GMC11F(A) - Walnut Finished GMC12U(A) - Unfinished Mantel features moldings, fluted sides and medal- lion. Available in walnut finished or unfinished hardwood, ready to stain or paint. Shown with optional base accessory. Dimensions (HxWxD): 44" x 57-3/4" x 22-7/8"
HEARTH BASE G3000F- Walnut Finished G3001U - Unfinished The hearth base creates a handsome riser for the fireplace. Dimensions (HxWxD): 6 1/2" x 58" x 28-9/16"
MANUAL SHUTOFF VALVE - GA5010 For all models. Manual shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.


Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR ON ALL COMPO- NENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSE- QUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
102664-01 Rev. B 06/96