IManuaily-Controlled Models Also Designed Certified as Vented Decorative Appliance) Thin apphance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of safe, not for purpose of resale, from the manufacturer OWNER'S OPERATION AND INSTALLATION MANUAL
18", 24", and 30" Variable
ManuallyControlled
CGD3924PT CGD3930PT
Models
CGD3018P CGD3924P CGD3930P
manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
u Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS
burning fireplace or an AGA design certP fled vent-free firebox listed for use with these gas log models (Including CGFB32C and CGFB32NC series)°
Installation and service must be per- formed by a qualified installer, service agency, or the gas supplier.
Save this manual for future reference.
Patent Pending



SAFETY INFORMATION
WARNING: Any change to this heater or its controls can be dangerous. " 1. This appliance is only for use with the type of gas indicated on the rating plate. Thi: appliance is not convertible for use with other gases, 2. Do not place propane (LP) supply tank(s) inside any structure. Locate propane (LP) supply tank(s) outdoors. 3. To prevent performance problems, do not use propane fuel tank ofless than 100 lbs. capacity. 4. If you smell gas
with flue damper closed. 8. If fireplace has glass doors, never operate this heater with glass doors closed. Ifyou operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater. 9. You must operate this heater with a fireplace screen in place. Make sure fireplace screen
is closed before running heater. !0. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater
and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues. 11. Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting. 12, Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater. 13. This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh airis available. See Air for Combustion and Ventilation, pages 5 through 8. If heater keeps shutting off, see Troubleshooting, pages 25 through 28. 14. Do not run heater


Crossover Log Log.
Figure 1 - Vent-Free Gas Log Heater Install and use heater with care. Follow all local codes. In the absence of local
codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.
*Available from:
Ameriean National Standards Institute, Inc. 1430 Broadway New York, NY 10018
National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269
permitted.
assembly by grate. 2. Remove all protective packaging applied to logs and heater for shipment. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.
Operation This heater is clean burning. It requires no outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent-free operation with flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters. You can operate heater as a vented product by opening flue damper.
Safety Pilot This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts 9ff the heater if there is not enough fresh air.
Piezo Ignition System This heater has a piezo ignitor. This system requires no matches, batteries, or other
sources to light heater.


WARNING
This heater shall not be installed in a confined space unless
provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today's homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home
owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as
airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances.
This will insure proper venting of vented fuel-burning appliances. PROVIDING ADEQUATE VENTILATION
The following is excerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction; 2. Unconfined Space; 3. Confined Space. The information on pages 5 through 7 will help you classify your space and provide
adequate ventilation.
Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction
you must provide additional fresh air.
Unusually tight construction Is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10 "11per pa.aec.m =) or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window
and door frames, between sole plates and floors, between wall-ceiling Joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide addi- tional fresh air. See Ventilation Air From Outdoors, page 7.
If your home does not meet all of the three criteria above, proceed to page 6.
Confined and Unconfined Space
The National Fuel Gas Code (ANSIZ223.1, 1992 Section 5.3) defines a confinod
space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8
m 3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3per kw) of the aggregate input rating of all appliances installed
in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
* Adjoining rooms are communicating only if there are doorless passageways or
ventilation grills between them. Continued _"
10_604


Determining if You Have a Confined or Unconfined Space- Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
(volume of space) + 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space) + 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)
Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr
Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* +.Btu/Hr Total = Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework wurksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7. C. Install a lower Btu/Hr heatar, if lowar Btu/Hr size makes room unconfined.
Iftbe actual Btu/Hr used is less than the maximum Btu/I-Irthe space can support, the space is an unconfined space. You will need no additional fresh air ventilation.


WARNING
If the area in which the heater may be operated is smaller than
that defined as an unconfined space, provide adequate combus- tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3 or appli- cable local codes.
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion
2nd Ventilation for required size of ventilation grills or ducts.
Rework worksheet, adding the space of the adjoining unconfined
space. The combined spaces must have enough fresh air to supply all appliances in both spaces.
Into Adjoining O_ Into Adjoining Room. Room, Remove II Op_on 2 Op_on 1 Door into li
Adjoining il Room, OptionOll
Figure 2 - Ventilation Air from Inside Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12"of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.
========== To c" spa=
Inka/U¢ I Verl_llted Cr,_s_= I 'ure 3 - Ventilation Air from Outdoors n IF4
Grills Ventila_on Gdlls · Outer


t NOTICE A qualified service person must install heater. Follow all local codes.
State or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes.
Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint
by a qualified chimney cleaner. Creosote will ignite if highly heated.
Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.
Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.
Never install the heater
This heater creates warm air currents. These currents move heat
to wall surfaces next to heater. Installing heater next to vinyl or
cloth wall coverings or operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.
Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.


TO COMBUSTIBLE MATERIALS
LOG SIZING REQUIREMENTS
Log Minimum Firebox Size
Size Height Depth Front Width 18" 17" 14" 20"
24" 17" 14= 26" 30" 17" 14" 32"
Carefully follow the instructions below. This will ensure safe installation into a masonry, U.L. listed manufactured fireplace, or AGA design certified vent-free firebox listed for use with these models.
Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches.
B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.
/
/
Figure 4. Minimum Clearance to Well end Ceiling


You may use this heater as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fire-
place opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 13.
Minimum Non-Combustible Material Clearances
If Not Using Mantel
You must have non-combustible material(s) above the fireplace opening. Non- combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non-combustible material behind it. Non- combustible material must extend at least 8" up (for all models). If non-combus-
tible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See chart below and Figure 5 for minimum clearances.
Requirements for Safe Installation
Non-combustible material okay.
Between 8" and 12"
24" or 30" Models: Install fireplace hood accessory (GA6050 or GA6052, see Accessories, page 33). 18" Model: Non-combustible matedal okay.
Non-combustible matedal must be extended to at least 8". See Between 8"and 12", above. If you cannot extend material, you must operate heater with flue damper open.
Heat Resistant -_ Material
Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace


Minimum Non-Combustible Material Clearances (Continued)
You must have non-combustible material(s) above the fireplace opening. Non- combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non-combustible material behind it. Non- combustible material must extend at least 8" up (for all models). If non-combus-
tible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even if non-combustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See chart below and Figures 6 and 7 for minimum clearances.
Non-Combustible Material Distance (A)
Requirements for Safe Installation
Non-combustible material okay.
Between 8" and 12"
24" or 30" Models: Install fireplace hood accessory (GA6050 or GA6052, see Accessories, page 33). 18" Model: Non-combustible material okay.
Non-combustible material must be extended to at
least 8". See Between 8" and 12", above. If you cannot extend material, you must operate heater with flue damper open.
In addition to meeting non-combustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances listed below, you will need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between mantel shelf and top of f'weplace open-
ing, a hood is not required (see Figure 6).
Mantel Shelf Underside of
All minimum distances are in inches
MinimumNon- _ i Combustiblfl ,, (A)
Log Set 30" _ 24"/30" Models
20" _ 18" Model
Top of Fireplace _ / Opening MinimumNon. Distancesto Combustible Undersideof
Figure 6. Minimum Mantel Clearances Without Using Hood


Determining Minimum Mantel Clearance When Using a Hood
If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7 when using hood.
Underside of Mantel Sheff
All minimum distances are
!0"
r Top of Fireplace
HOOd Distances to (GA6050, GA6052) Underside of Mantel
Figure 7- Minimum Mantel Clearances When Using Hood
If your installation does not meet the above minimum clearances, you must:
A. If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8). ]
Figure 8 - Minimum Fireplace Clearances ff Installed at Floor Level
B. If combustible materials are less than 14" to the fireplace, you must install
appliance at least 5" above the combustible flooring (see Figure 9).
Min.
_l_ ,, Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring


VENTED OPERATION
ContMued
fuel burning fireplace with a working flue and constructed of non-combustible material.
If your heater is a manually controlled model, you may use this heater as a vented
product. There are three reasons for operating your heater in the vented mode. 1. The fireplace does not meet the clearance to combustibles requirements for vent-free operation. 2. State or local codes do not permit vent-free operation.
If reasons number 1or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, seeAccessories, page 33). This will insure vented operation (see Figure 10). The damper clamp will keep
damper open. Installation instructions are included with clamp accessory.
See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permaneni flue opening will be maintained at all times.
Chimney Minimum Permanent Height (ft.) Flue Opening ($q. ins.)
6' to 15' 39 sq. inches 15' to 30' 29 sq. inches
Area of Various Standard Round Flues
Diameter (ins.) Area (sq. ins.)
5" 20 sq. inches 6" 29 sq. inches 7" 39 sq. inches 8" 51 sq. inches
Masonry Fireplace Manufactured Fireplace
Figure 10- Attaching Camper Clamp m Continued Ill
Damper F Clamp · ,o_04_


WARNING
You must secure this heater to fireplace floor. If not, heater will move
when you adjust controls. Moving heater may cause a gas leak.
if installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against soot- ing. Raise fireplace floor with non-combustible material. Make sure material is secure.
Do not pick up heater base assembly by the burner. This could
damage heater. Only handle base assembly by grates.
will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in
mounting bracket.
joint of bricks. 5. Remove heater base from fireplace. 6. Drill holes at marked locations using 3/16" drill bit. 7. Attach base assembly to fireplace floor using two masonry screws (in hardware
package) (see Figure 12, page 15). 8. Connect to gas supply. See Connecting To Gas Supply, page 15.
Fitting Flexible Gas Hose
(if allowed by local codes)
! _L_ Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator,, ,,_
Installation Items Needed · (_ Regulator eeter Gas


Figure 12 - Attaching Base Assembly to Fireplace Floor
NOTICE
A qualified service person must connect heater to gas supply. Follow all local codes.
Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external
regulator between the heater and propane supply.
Installation Items Needed Before installing heater, make sure you have the items listed below.
* An A.G.A. design-certified manual shutoffvalve with 1/8" NFFtap is an acceptabh alternative to test gauge connection. Purchase the optional A.G.A. design-eertifiex manual shutoff valve from your dealer. See Accessories, page 33.
Continue


The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and
14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.
Propane Supply Tank \
E erna,
Reou,ator
* <o*"-_ Vent Pointing 6"000 € .-, L • Down
Figure 13 - External Regulator With Vent Pointing Down
Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use
pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe ts too small, undue loss of pressure will occur.
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14, page 17).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
Install sediment trap in supply line as shown in Figure 14, page 17. Locate sedi- ment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.


Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.
A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap*
From Gas Meter (5" W.C*** to
// Approved Flexible // Gas Hose (if allowed ,_ / by local codes) /
Sediment Figure 14 - Gas Connection Trap
* Purchase theoptional A.G.A. design-certified manual shutoff valve from your dealer See Accessories, page 33. _'* Minimum inlet pressure for purpose of input adjustment.
WARNING
Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.
Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
Make sure external regulator has been Installed between propane supply end heater. See guidelines under Connecting to Gas Sup- ply, page 15.
Pressure Testing Gas Supply Piping system Test Pressures In Excess Of 1/2 PSIG
Pressure) · 3" Minimum · Continued I Ia_6_


Con_nued.
fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (seeFigure 15).
propane supply tank valve. 3. Check all joints from propane supply tank to manual shutoff valve (see Figure
16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Pressure Testing Heater Gas Connections
Manual • "_ Shutoff ,// Valve
Supply Ta__. __
i i i , i _ i _ i
_ ,L_, ,ff* -,-_, ,
Figure 16. Checking Gas Joints


WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do
not modify logs. Only use logs supplied with beater. 1. Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in the grate base behind the burner (see Figure 17). 2. Place the base ofthe middle log (#2) in the U-shaped slots of the grate base in front of the back log. The cutout on the right of the middle log should fit over the burner
(see Figure 18), Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is centered over the burner "U" bend. 3. Locate the recesses on the back of the front log (#3). Fit these recesses between the posts of the grate base (see Figure 19). 4. Locate the notches in the bottom of the crossover log (#4). Place the crossover log on top of the middle log and front log. Make sure the notches of the cross-
over log lines up with rectangular knobs on top of the middle and front logs (see Figure 20).
/_"_Back Log (#1) (_J_j Middle Log (#2)
Peg "(<.:"" -.1.. Hole in _ '- _. _.'.-., _
_,,,, " L_'_---%_,_"_% j ' Cut°ut ._./
_I "_"_I U-Shaped _J td Slot
Figure 17- Installing Back Log (#1) Figure 18 - Installing Middle Log (#2)
Front Log (#3) Notches _ Crossover
"_1<_'_ Rectangular _-,_p.,_ f
Flgure19. lnstalllng_Front:;#3) Fl::::. lnstalllng Cr "_o_ver Log (#_


HEATER.
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life,
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
knob will not push in or turn by hand, don't try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
WARNING
During initial operation of new heater, burning logs will give off a paper- burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.
Note: Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot ff heater has been running.
IgnitorButlon\ _Control Knob
Figure 21 - Control Knob and Ignitor Button Location


position. Press in control knob for five (5) seronds (see Page 20).
Figure 22 - Pilot
Do not operate heater between PILOT and HIGH positions.
The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in increased heating comfort.
Do not try to adjust heating levels by using the manual shutoff valve.
Shutting Off Burners Only (pilot stays lit)


HEATER
WARNING
if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot_ follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
WARNING
bottom, you must open the vents before operating heater.
During Initial operation of new heater, burning logs will give off a paper- burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.
Note: Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot if heater has been running.


ignitor Button.__" _ _ _COntrOI KnOb
Figure 23 - Control Knob and Ignitor Button Location
control knob for five (5) seconds (see above).
person or gas supplier for repairs.
Figure 24 - Pilot


HEATER
Shutting Off Burners Only (pilot stays lit)
The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
release control knob. Now follow step 8, page 23.
Check pilot flame pattern and burner flame patterns often.
Figure 25 shows a correct pilot flame pattern. Figure 26 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocoupl¢ cools, the heater will shut down.
Figure 25. Correct Pilot Flame Pattern
Figure 26 - Incorrect Pilot Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 24


WARNING
AND MAINTENANCE
Turn off heater and let cool before cleaning.
You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.
ODS/PILOT AND BURNER • Use a vacuum cleaner or small, soft bristled brush to clean.
WARNING
Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.
listed in order of
CAUTION
operation.
can damage ODS/pilot unit.
When ignitor button ts pressed, there is no
spark at ODS/pilot


Continued When ignitor button
is pressed, there is spark at ODS/pilot but no ignition
PILOT position 3. Control knob not
PILOT position 3. Press in control knob
pressed in while in PILOT position 4. Air in gas lines when installed
while in PILOT position
igniting operation until air is removed
gas company 6. Clean ODS/pilot (see Cleaning and Mainte- nance, page 25) or
replace ODS/pilot assembly 7. Replace gas regulator
flame goes out when control knob is released
pressed in 2. Control knob not
fully 2. After ODS/pilot lights,
pressed in long enough
keep control knob pressed in 30 seconds 3. Fully open manual shut- off valve
not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to
cool, causing pilot flame to go out. This problem could be caused by one or both of the following:
B) Clean ODS/pilot (see Cleaning and Mainte- nance, page 25) or repl_e ODS/pilot assembly
A) Low gas pressure B) Dirty or partially clogged ODS/pilot
ODS/pilot lights but · pane gas company


Continued Burner does light
after ODS/pilot is lit
Delayed ignition of bumer
Bumer backfiring during combustion
Slight smoke or odor during initial operation
Moisture!condensa- 1. Not enough combus- 1. Refer to Air for Com- tion noticed on tion/ventilation air bustion and Ventilation
windows requirements (page 5)
Heater produces a whistling noise
I.Turningcontrolknob
toHI positionwhen burneriscold 2. Air in gas line
when burner is lit
for a minute 2. Operate burner until air is removed from line. Have gas line checked by local natural gas company 3. Observe minimum installation clearances (see pages 9-12) 4. Clean burner (see Cleaningand Maintenance, page 25) or replace
burner orifice


TROUBLE- SHOOTING.
Heater produces a clicking/ticking noise ust after burner is lit or shut off
Heater produces unwanted odors
Open window and ventilate room. Stop using odor causing products while heater is running
Locate and correct all
leaks (see Checking Gas Connections, page 17)
Heater shuts off in use
Gas odoreven when control knob is in OFF
I. Locate and correct all
leaks (see Checking Gas Connections, page 17) 2. Replace control valve
leaks (see Checking Gas
Logs set cycles m pilot, but room temperature drops to a lower than ideal level
before log set comes back on
(ODS operates) · )osition · Connections, page 17)


If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you maywant to reposition the thermostat sensing bulb.
The thermostat sensing bulb is located near the gas valve assembly on the mounting bracket. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. For positioning the thermostat sensing bulb elsewhere, an adhesive-backed mounting clip has been provided.
l. Remove logs. Locate the gas valve assembly and thermostat sensing bulb (see Figure 27).
Mounting Thermostat Bracket Sensing Bulb
Figure 27- Location of Gas Valve Assembly and Thermostat Sensing Bulb
Figure 28 - Adhesive-backed Mounting Clip
3, With 1/4" hex driver or socket, loosen the thermostat screw. Carefully slide the thermo- stat sensing bulb out of the retaining clamp (see Figure 29).
Retaining Claml:
Figure 29 - Removing Thermostat Sensing Bulb
have a masonry fireplace, see Figure 30 on page 30 for location. Continued I


I-, Thermostat L.
OF THERMOSTAT SENSING BULB
Figure 30 - Locating Thermostat Sensing Bulb on Masonry Fireplace
Factory-built Metal Fireplace
If you have a factory-built metal fireplace, see Figure 31 for location.
Figure 31 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace
If your ftreplace has glass doors, position sensing bulb directly behind door gap on right bottom side (see Figure 32).
Figure 32 - Installing Thermostat Sensing Bulb behind Glass Doors
sensing bulb will be positioned vertically with the capillary at the bottom (see Figure 33). Slide the thermostat sensing bulb into the clip.
Adhesive-backed • Mounting Clip
Do Not Crimp Capillary
Figure 33. Positioning the Thermostat Sensing Bulb In the Vertical Position with the Capillary at the Bottom


You may have further questions about installation, operation, or ti'oubleshooting. If so, contact DESA International's Technical Service Department at 1-800-DESA LOG (I-800-337-2564).
SPECIFICATIONS
18" Model 24" Models 30" Models
Btu (Variable) 16,000/30,000 20,000/39,000 20,000/39,000
Type Gas Propane Only Propane Only Propane Only
Ignition Piezo Piezo Piezo
Manifold Pressure 8.0" W.C. 8.0" W.C. 8.0" W.C.
Pressure (in. of water) Maximum 14" 14" 14" Minimum* 11" 11" t 1"
30 lbs. 32 lbs.
Shipping Weight 28 Ibs.
* For the purpose of input adjustment
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.
Inlet Gas


Parts Under Warranty Contact authorized dealers of this product. If they can't supply original replace- ment part(s), call DESA International's Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
When calling DESA International, have ready
Parts Not Under Warranty Contact authorized dealers of this product. If they can't supply original replace- ment part(s), call DESA International's Parts Department at 1-800-972-7879 for referral information.
These Parts Centrals are privately owned businesses. They have agreed to support our customer's needs by providing original replacement parts and accessories.
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department
Washer Equipment Co. 1715 Main Street Kansas City, Me 64108 KS, Me, AR 816-842-3911
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426
East Coast Energy Products 833 Broadway W. Long Branch, N,J 07764 906-870-8809 1-800-755-8809
Hal¢o Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 215-696-2670 1-800-368-0803
342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951
FBD 1349 AdamsStreet BowlingGreen, KY 42103 502-846-8534 1-800-654-8534 Fax: 1-800-846-0090
Tarantln Tank Co. • P.O. Box6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724
LA Porte's Parts & Service 2444 N. 5th Street HartsvUle, SC 29550 803-332-0191 Parts Department
Albany Ladder 1586-90 Central Avenue Albany, NY 12205 NY, MA, V'I" 518-869-5335 1-800-354-7368
Four Rags Power Products 1115 Stateline Road Niles, MI 49120 616-684-2697 Parts Only
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States
Master Service Center 1184 Wilson NW Walker, MI 49504 616-791-4760 1-800446-1446
Portable Heater Parts · 803-879-3009 1-800-845-5301 · 103d04


Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International's Sales Department at 1-'800-472-7879
for referral information. You can also write to the address listed on the back page of this manual.
MANUAL SHUTOFF VALVE - GA5010 For all models. Manual shutoff valve
with 1/8" NPT tap, Fits 112" NPT pipe.
BLACK FIREPLACE HOOD - GA6050 For all models. Helps deflect heat away from mantel or wall above fireplace.
For all models. Helps deflect heat away from mantel or wall above
fireplace.
For variably controlled models. Permanently opens chimney flue damper for vented operation (see Installing Damper Clamp Accessory for Vented Operation, page 13).
LAVA ROCK - GA6060 For all models. Order when additional
rock is desired. (3 lb. bag)


PARTS BREAKDOWN
CGD3018P CGD3924P CGD3930P
/o3eo4


PARTS LIST This list contains replaceable parts usedin your heater. When ordering parts, follow
the instructions listed under Replacement Parts on page 32 of this manual.
CGD3018P CGD3924P CGD3930P PART NUMBER PART NUMBER PART NUMBER DESCRIPTION KEY NO.
QTY.
1 103008-02 2 103009-02 3 103010-02 4 103011-02 5 102775-04CK 6 102844-02 7 102966-02 8 098887-10 9 102798-01 10 102779-04 11 099056-19 12 102843-01 13 102980-01 14 102568-08 18 098508-01
Back Log (#1) 1
Middle Log (#2) 1 Front Log (#3) 1 Crossover Log (#4) 1 Painted Base Assembly 1 Lower Bracket 1
103011-01 102775-01CK 102844-01 102966-01 098867-10 102798-01 102779-02 099056-17 102843-01 102772-01 102568-06 098508-01 098354-01 102445-01 099387-08 098271-07 099059-02 098594-01 098593-01 Ml1084-38 098276-01 098249-01
103011-03 102775-03CK 102844-01 102966-01 098867-10 102798-01 102779-02 099056-17 102843-01 102772-01 102568-06 098508-01
Gas Regulator 1 Inlet Tube 1 Outlet Burner Tube 1
Burner Orifice Injector 1 Burner Clip 1 Burner 1 Control Valve 1 Valve Retainer Nut 1 Control Knob 1
16 098354-01 17 102445-01 18 099387-08 19 098271-07 20 099059-02 20-1 098594-01 20-2 098593-01 21 Ml1084-38 22 098276-01 23 098248-01
098354-01 102445-01 099387-08 098271-07 099059-02 098594-01 098893-01 Ml1084-38 098276-01 098249-01
Piezo Ignitor 1 Pilot Tube 1
Ignitor Cable 1 ODS Pilot 1
Ignitor Electrode 1 Thermocouple 1 Hex Screw, #8-18 x .38 11 Hex Head Plug, 1/8 NPT 1 Nut, M5 2
100563-01 101055-02 100565-01 100639-01 101449-04 101137-02 101416-33
100563-01 101055-02 100565-01 100639-01 101449-04 101137-02
101415-33 GA6060
GA6060


PARTS BREAKDOWN
CGD3924PT CGD3930PT
20-1 20 · _t 14 \


PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 32 of this manual.
KEY CGD3924PT CGD3930PT NO. PART NUMBER PART NUMBER DESCRIPTION
QTY.
1 103008-01 2 103009-01 3 103010-01 4 103011-01
Back Log (#1) Middle Log (#2) Front Log (#3) Crossover Log (#4)
1 1 1 1
Painted Base Assembly Lower Bracket
Upper Bracket Gas Regulator inlet Tube Outlet Burner Tube
6 098867-10 9 102981-01 10 1102983-02 11 099066-17
12 102843-01 13 102772-01 14 101329-19
101329-19 102979-01 098544-01 102445-01 099387-09 098271-07 099059-02 098594-0! 098593-01 Ml1084-38 098249-01 099211-01
Thermostat Gas Valve Assembly Thermostat Bracket
15 102979-01 16 098544-01 17 102445-01 18 099387-09
1 1 1 15
Thermobulb Clip Piezo Ignitor Pilot Tube
19 098271-07 20 099059-02 20-1 i098594-01 20-2 098593-01 21 Ml1084-38 22 096249-01 23 099211-01
Ignitor Cable ODS Pilot
Ignitor Electrode Thermocouple Hex Screw, #8-18 x .38 Nut, M5 Hex Screw, 10-16 x 2.50
100563-01 101054-01 100565-01 100639-01 101137-02 101416-33 GA6060
100563-01 101054-01 100565-01 100639-01 101137-02 101416-33 GA6060
Hardware Kit Information Video Lava Rock


f 0,,_o4




Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
COMFORT GLOW VENT-FREE PROPANE GAS LOG HEATERS
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all loca! codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or
become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MER- CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL'S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES,
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty wrim:
2701 Industrial Ddve P.O. Box 90004 Bowling Green, KY 42102-9004
103604-01 Rev. A 5/97