Table of Contents 80 sections YELLOW FLAME DESIGN UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER · 24" and 30" ThermostaticallyControlled Models · 18", 24", and 30" Variable · ManuallyControlled · … ShowHide
YELLOW FLAME DESIGN UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATERp.124" and 30" ThermostaticallyControlled Modelsp.118", 24", and 30" Variablep.1ManuallyControlledp.1CGD3924PT CGD3930PTp.1Modelsp.1CGD3018P CGD3924P CGD3930Pp.1WARNING: If the information in thisp.1CONTENTSp.2SECTION PAGEp.2SAFETY INFORMATIONp.2A WARNINGSp.2A DANGERp.2WARNINGS Continuedp.3I0_04p.3PRODUCT IDENTIFICATIONp.4LOCAL CODESp.4UNPACKINGp.4PRODUCT FEATURESp.4AIR FOR COMBUSTIONp.5WARNINGp.5AND VENTILATIONp.5DETERMINING AIR FLOW FOR HEATER LOCATIONp.6VENTILATION AIR Ventilation Air From Inside Buildingp.7Ven--p.7/_ir I TO Atticp.7========== To c" spa=p.7NOTICEp.8CAUTIONp.8CHECK GAS TYPEp.8INSTALLATION AND CLEARANCES (Vent-Free Operation Only)p.9MINIMUM FIREPLACE CLEARANCEp.9TO COMBUSTIBLE MATERIALSp.9LOG SIZING REQUIREMENTSp.9i 16 Left and Rightp.9mlp.10Mantel Clearancesp.11/ 8" 14" 163/4 , 181Q" /p.11,,,kp.11Floor Clearancesp.121O36O4p.12INSTALLING DAMPER CLAMP ACCESSORY FORp.13VENTED OPERATIONp.13ContMuedp.13Damper Oon,porp.13INSTALLING HEATER BASE ASSEMBLYp.14Mo2p.15CONNECTING TO GAS SUPPLYp.15Propane Supply Tank \p.16E erna,p.16Reou,atorp.1610.5" W.C,p.17CHECKING GAS CONNECTIONSp.17Thermostat Gas Valve or Control Valve Location /p.18INSTALLING LOGSp.19GrateBase<_._.._ , :1 "at -p.19OPERATINGp.201 FOR YOUR SAFETY READ BEFORE LIGHTING /p.20ManuallyControlled Modelsp.20LIGHTING INSTRUCTIONSp.20HEATERp.21VARIABLE CONTROL OPERATIONp.21TO TURN OFF GAS TO APPLIANCEp.21MANUAL LIGHTING PROCEDUREp.22ThermostaticallyControlled Modelsp.223. Turn control knob clockwise _ to the OFF position. . g!LniWp.23TO TURN OFF GAS TO APPLIANCE "p.24THERMOSTAT CONTROL OPERATIONp.24INSPECTINGp.24BURNERSp.24CLEANINGp.25AND MAINTENANCEp.25LOGSp.25TROUBLESHOOTINGp.25Note: All troubleshooting items arep.25listed in order ofp.25'Never use a wire, needle, or similar object to clean ODS/pilot. Thisp.25OBSERVED POSSIBLE PROBLEM CAUSE REMEDYp.25TO_p.25OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTINGp.26
Page 1 of the Desa Tech CGD3930PT user manual — WARNING: If the information in this
Page 1 · click to enlarge
Page 1
Desa Tech CGD3930PT — YELLOW FLAME DESIGN UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER diagram (page 1)
Fig. 1

YELLOW FLAME DESIGN UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER

IManuaily-Controlled Models Also Designed Certified as Vented Decorative Appliance) Thin apphance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of safe, not for purpose of resale, from the manufacturer OWNER'S OPERATION AND INSTALLATION MANUAL

24" and 30" ThermostaticallyControlled Models

18", 24", and 30" Variable

ManuallyControlled

CGD3924PT CGD3930PT

Models

CGD3018P CGD3924P CGD3930P

WARNING: If the information in this

manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

u Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor's phone. Followthe gas supplier's Instructions.
  • If you cannot reach your gas supplier, call the fire department.

burning fireplace or an AGA design certP fled vent-free firebox listed for use with these gas log models (Including CGFB32C and CGFB32NC series)°

Installation and service must be per- formed by a qualified installer, service agency, or the gas supplier.

Save this manual for future reference.

Patent Pending

Page 2 of the Desa Tech CGD3930PT user manual — Table of Contents
Page 2 · Contents
Contents

Contents

YELLOW FLAME DESIGN UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATERp.124" and 30" ThermostaticallyControlled Modelsp.118", 24", and 30" Variablep.1ManuallyControlledp.1CGD3924PT CGD3930PTp.1Modelsp.1CGD3018P CGD3924P CGD3930Pp.1WARNING: If the information in thisp.1CONTENTSp.2SECTION PAGEp.2SAFETY INFORMATIONp.2A WARNINGSp.2A DANGERp.2WARNINGS Continuedp.3I0_04p.3PRODUCT IDENTIFICATIONp.4LOCAL CODESp.4UNPACKINGp.4PRODUCT FEATURESp.4AIR FOR COMBUSTIONp.5WARNINGp.5AND VENTILATIONp.5DETERMINING AIR FLOW FOR HEATER LOCATIONp.6VENTILATION AIR Ventilation Air From Inside Buildingp.7Ven--p.7/_ir I TO Atticp.7========== To c" spa=p.7NOTICEp.8CAUTIONp.8CHECK GAS TYPEp.8INSTALLATION AND CLEARANCES (Vent-Free Operation Only)p.9MINIMUM FIREPLACE CLEARANCEp.9TO COMBUSTIBLE MATERIALSp.9LOG SIZING REQUIREMENTSp.9i 16 Left and Rightp.9mlp.10Mantel Clearancesp.11/ 8" 14" 163/4 , 181Q" /p.11,,,kp.11Floor Clearancesp.121O36O4p.12INSTALLING DAMPER CLAMP ACCESSORY FORp.13VENTED OPERATIONp.13ContMuedp.13Damper Oon,porp.13INSTALLING HEATER BASE ASSEMBLYp.14Mo2p.15CONNECTING TO GAS SUPPLYp.15Propane Supply Tank \p.16E erna,p.16Reou,atorp.1610.5" W.C,p.17CHECKING GAS CONNECTIONSp.17Thermostat Gas Valve or Control Valve Location /p.18INSTALLING LOGSp.19GrateBase<_._.._ , :1 "at -p.19OPERATINGp.201 FOR YOUR SAFETY READ BEFORE LIGHTING /p.20ManuallyControlled Modelsp.20LIGHTING INSTRUCTIONSp.20HEATERp.21VARIABLE CONTROL OPERATIONp.21TO TURN OFF GAS TO APPLIANCEp.21MANUAL LIGHTING PROCEDUREp.22ThermostaticallyControlled Modelsp.223. Turn control knob clockwise _ to the OFF position. . g!LniWp.23TO TURN OFF GAS TO APPLIANCE "p.24THERMOSTAT CONTROL OPERATIONp.24INSPECTINGp.24BURNERSp.24CLEANINGp.25AND MAINTENANCEp.25LOGSp.25TROUBLESHOOTINGp.25Note: All troubleshooting items arep.25listed in order ofp.25'Never use a wire, needle, or similar object to clean ODS/pilot. Thisp.25OBSERVED POSSIBLE PROBLEM CAUSE REMEDYp.25TO_p.25OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTINGp.26
Page 3 of the Desa Tech CGD3930PT user manual — I0_04
Page 3 · click to enlarge
Page 3
Desa Tech CGD3930PT — WARNINGS Continued diagram (page 3)
Fig. 2 · WARNINGS Continued

WARNINGS Continued

SAFETY INFORMATION

WARNING: Any change to this heater or its controls can be dangerous. " 1. This appliance is only for use with the type of gas indicated on the rating plate. Thi: appliance is not convertible for use with other gases, 2. Do not place propane (LP) supply tank(s) inside any structure. Locate propane (LP) supply tank(s) outdoors. 3. To prevent performance problems, do not use propane fuel tank ofless than 100 lbs. capacity. 4. If you smell gas

  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor' s phone. Follow the gas supplier' s instructions
  • if you cannot reach your gas supplier, call the fire department 5. This heater shall not be installed in a bedroom or bathroom unless installed as a vented appliance (Variable Manually-Controlled Models Only) (see page 13). 6. Never install the heater
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • in high traffic areas
  • in windy or drafty areas 7. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater

with flue damper closed. 8. If fireplace has glass doors, never operate this heater with glass doors closed. Ifyou operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater. 9. You must operate this heater with a fireplace screen in place. Make sure fireplace screen

is closed before running heater. !0. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater

and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues. 11. Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting. 12, Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater. 13. This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh airis available. See Air for Combustion and Ventilation, pages 5 through 8. If heater keeps shutting off, see Troubleshooting, pages 25 through 28. 14. Do not run heater

  • where flammable liquids or vapors are used or stored
  • under dusty conditions 15. Do not use this heater to cook food or burn paper or other objects. 16. Never place any objects on the heater. 17. Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching. 18. Carefully supervise young children when they are in the room with heater. 19. Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the conU'ol system and any gas control which has been under water. 20. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dimesized or larger). 21. Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater.
22. Operating heater above elevations of 4,500 feet could cause pilot outage, m_

I0_04

Page 4 of the Desa Tech CGD3930PT user manual — PRODUCT FEATURES
Page 4 · click to enlarge
Page 4
Desa Tech CGD3930PT — PRODUCT IDENTIFICATION diagram (page 4)
Fig. 3

PRODUCT IDENTIFICATION

Crossover Log Log.

Figure 1 - Vent-Free Gas Log Heater Install and use heater with care. Follow all local codes. In the absence of local

LOCAL CODES

codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.

*Available from:

Ameriean National Standards Institute, Inc. 1430 Broadway New York, NY 10018

National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269

permitted.

UNPACKING

1. Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base

assembly by grate. 2. Remove all protective packaging applied to logs and heater for shipment. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

PRODUCT FEATURES

Operation This heater is clean burning. It requires no outside venting. There is no heat loss out a

vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent-free operation with flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters. You can operate heater as a vented product by opening flue damper.

Safety Pilot This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts 9ff the heater if there is not enough fresh air.

Piezo Ignition System This heater has a piezo ignitor. This system requires no matches, batteries, or other

sources to light heater.

Show 4 more labels / short text on this page
Front Log · Ignitor · Contr¢ · 70a_4
Page 5 of the Desa Tech CGD3930PT user manual — AND VENTILATION
Page 5 · click to enlarge
Page 5
Desa Tech CGD3930PT — AIR FOR COMBUSTION diagram (page 5)
Fig. 4

AIR FOR COMBUSTION

WARNING

This heater shall not be installed in a confined space unless

AND VENTILATION

provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today's homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home

owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as

airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances.

This will insure proper venting of vented fuel-burning appliances. PROVIDING ADEQUATE VENTILATION

The following is excerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction; 2. Unconfined Space; 3. Confined Space. The information on pages 5 through 7 will help you classify your space and provide

adequate ventilation.

Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction

you must provide additional fresh air.

Unusually tight construction Is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10 "11per pa.aec.m =) or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window

and door frames, between sole plates and floors, between wall-ceiling Joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide addi- tional fresh air. See Ventilation Air From Outdoors, page 7.

If your home does not meet all of the three criteria above, proceed to page 6.

Confined and Unconfined Space

The National Fuel Gas Code (ANSIZ223.1, 1992 Section 5.3) defines a confinod

space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8

m 3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3per kw) of the aggregate input rating of all appliances installed

in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

* Adjoining rooms are communicating only if there are doorless passageways or

ventilation grills between them. Continued _"

10_604

Page 6 of the Desa Tech CGD3930PT user manual — AND VENTILATION
Page 6 · click to enlarge
Page 6
Desa Tech CGD3930PT — DETERMINING AIR FLOW FOR HEATER LOCATION diagram (page 6)
Fig. 5

AIR FOR COMBUSTION

DETERMINING AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space- Use this work sheet to determine if you have a confined or unconfined space.

AND VENTILATION

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1. Determine the volume of the space (length x width x height).

Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space) + 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) + 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3. Add the Btu/Hr of an fuel burning appliances in the space.

Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr

Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* +.Btu/Hr Total = Btu/Hr

ExampleGas water heater 40,000 Btu/Hr Vent-free heater + 39,000 Btu/Hr Total = 79,000 Btu/Hr

* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used)

Example51,200 Btu/T-Ir(maximum the spacecan support) 79,000 Btu/Hr (actual amount of BtuiHr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A. Rework wurksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7. C. Install a lower Btu/Hr heatar, if lowar Btu/Hr size makes room unconfined.

Iftbe actual Btu/Hr used is less than the maximum Btu/I-Irthe space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Page 7 of the Desa Tech CGD3930PT user manual — /_ir I TO Attic
Page 7 · click to enlarge
Page 7
Desa Tech CGD3930PT — VENTILATION AIR Ventilation Air From Inside Building diagram (page 7)
Fig. 6 · VENTILATION AIR Ventilation Air From Inside Building

AIR FOR COMBUSTION

WARNING

If the area in which the heater may be operated is smaller than

AND VENTILATION

that defined as an unconfined space, provide adequate combus- tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3 or appli- cable local codes.

VENTILATION AIR Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion

2nd Ventilation for required size of ventilation grills or ducts.

WARNING

Rework worksheet, adding the space of the adjoining unconfined

space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ven--

Into Adjoining O_ Into Adjoining Room. Room, Remove II Op_on 2 Op_on 1 Door into li

Adjoining il Room, OptionOll

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12"of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

/_ir I TO Attic

========== To c" spa=

Inka/U¢ I Verl_llted Cr,_s_= I 'ure 3 - Ventilation Air from Outdoors n IF4

Grills Ventila_on Gdlls · Outer

Page 8 of the Desa Tech CGD3930PT user manual — CHECK GAS TYPE
Page 8 · click to enlarge
Page 8
Desa Tech CGD3930PT — NOTICE diagram (page 8)
Fig. 7

t NOTICE A qualified service person must install heater. Follow all local codes.

NOTICE

State or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes.

WARNING

Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint

by a qualified chimney cleaner. Creosote will ignite if highly heated.

Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.

WARNING

Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

WARNING

Never install the heater

  • in a bedroom or bathroom unless installed as ave, nted appli-
  • ance (Variable Manually-Controlled Models Only) (see page 13)
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • in high traffic areas
  • in windy or drafty areas

CAUTION

This heater creates warm air currents. These currents move heat

to wall surfaces next to heater. Installing heater next to vinyl or

cloth wall coverings or operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.

CHECK GAS TYPE

Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.

Page 9 of the Desa Tech CGD3930PT user manual — i 16 Left and Right
Page 9 · click to enlarge
Page 9
Desa Tech CGD3930PT — INSTALLATION AND CLEARANCES (Vent-Free Operation Only) diagram (page 9)
Fig. 8 · INSTALLATION AND CLEARANCES (Vent-Free Operation Onl…

INSTALLATION AND CLEARANCES (Vent-Free Operation Only)

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

LOG SIZING REQUIREMENTS

Log Minimum Firebox Size

Size Height Depth Front Width 18" 17" 14" 20"

24" 17" 14= 26" 30" 17" 14" 32"

Carefully follow the instructions below. This will ensure safe installation into a masonry, U.L. listed manufactured fireplace, or AGA design certified vent-free firebox listed for use with these models.

Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches.

B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

i 16 Left and Right

/

/

Figure 4. Minimum Clearance to Well end Ceiling

Show 6 more labels / short text on this page
Log Size · Side Wall Ceiling · 18,24,30 · 16• 42" · 42" · Sides
Page 10 of the Desa Tech CGD3930PT user manual — ml
Page 10 · click to enlarge
Page 10
Desa Tech CGD3930PT — ml diagram (page 10)
Fig. 9 · ml

NOTICE

You may use this heater as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fire-

place opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 13.

Minimum Non-Combustible Material Clearances

If Not Using Mantel

You must have non-combustible material(s) above the fireplace opening. Non- combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non-combustible material behind it. Non- combustible material must extend at least 8" up (for all models). If non-combus-

tible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See chart below and Figure 5 for minimum clearances.

Requirements for Safe Installation

Non-combustible material okay.

Between 8" and 12"

24" or 30" Models: Install fireplace hood accessory (GA6050 or GA6052, see Accessories, page 33). 18" Model: Non-combustible matedal okay.

Non-combustible matedal must be extended to at least 8". See Between 8"and 12", above. If you cannot extend material, you must operate heater with flue damper open.

Heat Resistant -_ Material

ml

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

Show 4 more labels / short text on this page
Non-Combustible · Material Distance (A) · 12" or more · Less than 8"
Page 11 of the Desa Tech CGD3930PT user manual — ,,,k
Page 11 · click to enlarge
Page 11
Desa Tech CGD3930PT — Mantel Clearances diagram (page 11)
Fig. 10 · Mantel Clearances

Minimum Non-Combustible Material Clearances (Continued)

You must have non-combustible material(s) above the fireplace opening. Non- combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non-combustible material behind it. Non- combustible material must extend at least 8" up (for all models). If non-combus-

tible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even if non-combustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See chart below and Figures 6 and 7 for minimum clearances.

Non-Combustible Material Distance (A)

Requirements for Safe Installation

Non-combustible material okay.

Between 8" and 12"

24" or 30" Models: Install fireplace hood accessory (GA6050 or GA6052, see Accessories, page 33). 18" Model: Non-combustible material okay.

Non-combustible material must be extended to at

least 8". See Between 8" and 12", above. If you cannot extend material, you must operate heater with flue damper open.

Mantel Clearances

In addition to meeting non-combustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances listed below, you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of f'weplace open-

ing, a hood is not required (see Figure 6).

Mantel Shelf Underside of

All minimum distances are in inches

MinimumNon- _ i Combustiblfl ,, (A)

Log Set 30" _ 24"/30" Models

  • Matedal / 12" 20" 241,2
  • 271,2

/ 8" 14" 163/4 , 181Q" /

20" _ 18" Model

Top of Fireplace _ / Opening MinimumNon. Distancesto Combustible Undersideof

Figure 6. Minimum Mantel Clearances Without Using Hood

,,,k

Show 7 more labels / short text on this page
If Using Mantel · 12" or more · Less than 8" · Mantel Shelf · j m_ · MaterialHeight Mantel · Continued _l_
Page 12 of the Desa Tech CGD3930PT user manual — 1O36O4
Page 12 · click to enlarge
Page 12
Desa Tech CGD3930PT — Floor Clearances diagram (page 12)
Fig. 11 · Floor Clearances

Determining Minimum Mantel Clearance When Using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7 when using hood.

Underside of Mantel Sheff

All minimum distances are

!0"

r Top of Fireplace

HOOd Distances to (GA6050, GA6052) Underside of Mantel

Figure 7- Minimum Mantel Clearances When Using Hood

If your installation does not meet the above minimum clearances, you must:

  • operate the logs only with the flue damper open, OR
  • raise the mantel to an acceptable height, OR
  • remove the mantel.

Floor Clearances

A. If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8). ]

Figure 8 - Minimum Fireplace Clearances ff Installed at Floor Level

B. If combustible materials are less than 14" to the fireplace, you must install

appliance at least 5" above the combustible flooring (see Figure 9).

Min.

_l_ ,, Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring

1O36O4

Show 15 more labels / short text on this page
Mantel Sheff · m'_m · Minimum Non- CombuslJble Material · in inches · Log Set · 12" 15" 18" · r · k · Opening · Combustible 14" Material · \\\\\\\\\1 · _"_'Non-Combustible Material · Hearth · Combustible · Matede[
Page 13 of the Desa Tech CGD3930PT user manual — Damper Oon,por
Page 13 · click to enlarge
Page 13
Desa Tech CGD3930PT — INSTALLING DAMPER CLAMP ACCESSORY FOR diagram (page 13)
Fig. 12

INSTALLING DAMPER CLAMP ACCESSORY FOR

VENTED OPERATION

ContMued

fuel burning fireplace with a working flue and constructed of non-combustible material.

If your heater is a manually controlled model, you may use this heater as a vented

product. There are three reasons for operating your heater in the vented mode. 1. The fireplace does not meet the clearance to combustibles requirements for vent-free operation. 2. State or local codes do not permit vent-free operation.

3. You prefer vented operation.

If reasons number 1or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, seeAccessories, page 33). This will insure vented operation (see Figure 10). The damper clamp will keep

damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permaneni flue opening will be maintained at all times.

Chimney Minimum Permanent Height (ft.) Flue Opening ($q. ins.)

6' to 15' 39 sq. inches 15' to 30' 29 sq. inches

Area of Various Standard Round Flues

Diameter (ins.) Area (sq. ins.)

5" 20 sq. inches 6" 29 sq. inches 7" 39 sq. inches 8" 51 sq. inches

Damper Oon,por

Masonry Fireplace Manufactured Fireplace

Figure 10- Attaching Camper Clamp m Continued Ill

Damper F Clamp · ,o_04_

Page 14 of the Desa Tech CGD3930PT user manual — CAUTION
Page 14 · click to enlarge
Page 14
Desa Tech CGD3930PT — INSTALLING HEATER BASE ASSEMBLY diagram (page 14)
Fig. 13

INSTALLING HEATER BASE ASSEMBLY

WARNING

You must secure this heater to fireplace floor. If not, heater will move

when you adjust controls. Moving heater may cause a gas leak.

WARNING

if installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against soot- ing. Raise fireplace floor with non-combustible material. Make sure material is secure.

CAUTION

Do not pick up heater base assembly by the burner. This could

damage heater. Only handle base assembly by grates.

will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in

mounting bracket.

  • hardware package (provided with heater)
  • approved flexible gas hose (not provided) (if allowed by local codes)
  • sealant resistant to propane (propane/LP) gas, not provided
  • electric drill with 3/16" drill bit
1. Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11). IMPORTANT:Hold gas regulator with wrench when connecting flexible gas hose. 2. Locate masonry screws in hardware package. 3. Position heater base assembly in fireplace. 4. Mark screw locations through holes in mounting brackets (see Figure 12, page 15). If installing in a brick-bottom fireplace, mark screw locations in mortar

joint of bricks. 5. Remove heater base from fireplace. 6. Drill holes at marked locations using 3/16" drill bit. 7. Attach base assembly to fireplace floor using two masonry screws (in hardware

package) (see Figure 12, page 15). 8. Connect to gas supply. See Connecting To Gas Supply, page 15.

Fitting Flexible Gas Hose

(if allowed by local codes)

! _L_ Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator,, ,,_

Installation Items Needed · (_ Regulator eeter Gas

Page 15 of the Desa Tech CGD3930PT user manual — CAUTION
Page 15 · click to enlarge
Page 15
Desa Tech CGD3930PT — Mo2 diagram (page 15)
Fig. 14 · Mo2

Mo2

Figure 12 - Attaching Base Assembly to Fireplace Floor

CONNECTING TO GAS SUPPLY

NOTICE

A qualified service person must connect heater to gas supply. Follow all local codes.

CAUTION

Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external

regulator between the heater and propane supply.

Installation Items Needed Before installing heater, make sure you have the items listed below.

  • external regulator (supplied by installer, see page 16)
  • piping (check local codes)
  • test gauge connection *
  • sediment trap
  • tee joint
  • pipe wrench
  • sealant (resistant to propaneJLP gas)
  • manual shutoff valve *

* An A.G.A. design-certified manual shutoffvalve with 1/8" NFFtap is an acceptabh alternative to test gauge connection. Purchase the optional A.G.A. design-eertifiex manual shutoff valve from your dealer. See Accessories, page 33.

Continue

Page 16 of the Desa Tech CGD3930PT user manual — CAUTION
Page 16 · click to enlarge
Page 16
Desa Tech CGD3930PT — Propane Supply Tank \ diagram (page 16)
Fig. 15 · Propane Supply Tank \

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and

14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

T

Propane Supply Tank \

E erna,

Reou,ator

* <o*"-_ Vent Pointing 6"000 € .-, L • Down

Figure 13 - External Regulator With Vent Pointing Down

CAUTION

Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use

pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe ts too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14, page 17).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION

Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

Install sediment trap in supply line as shown in Figure 14, page 17. Locate sedi- ment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Page 17 of the Desa Tech CGD3930PT user manual — CAUTION
Page 17 · click to enlarge
Page 17
Desa Tech CGD3930PT — 10.5" W.C, diagram (page 17)
Fig. 16

CAUTION

Contmued

Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap*

From Gas Meter (5" W.C*** to

// Approved Flexible // Gas Hose (if allowed ,_ / by local codes) /

10.5" W.C,

Sediment Figure 14 - Gas Connection Trap

* Purchase theoptional A.G.A. design-certified manual shutoff valve from your dealer See Accessories, page 33. _'* Minimum inlet pressure for purpose of input adjustment.

CHECKING GAS CONNECTIONS

WARNING

Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION

Make sure external regulator has been Installed between propane supply end heater. See guidelines under Connecting to Gas Sup- ply, page 15.

Pressure Testing Gas Supply Piping system Test Pressures In Excess Of 1/2 PSIG

1. DisconneCt heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected.

Pressure) · 3" Minimum · Continued I Ia_6_

Page 18 of the Desa Tech CGD3930PT user manual — Thermostat Gas Valve or Control Valve Location /
Page 18 · click to enlarge
Page 18
Desa Tech CGD3930PT — Thermostat Gas Valve or Control Valve Location / diagram (page 18)
Fig. 17 · Thermostat Gas Valve or Control Valve Location /
3. Pressurize supply piping system by either using compressed air of opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints• Bubbles forming show a leak. 5. Correct all leaks at once.

Con_nued.

6. Reconnect heater and manual shutoff valve to gas supply. Check reconnected

fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (seeFigure 15).

2. Pressurize supply piping system by either using compressed air or opening

propane supply tank valve. 3. Check all joints from propane supply tank to manual shutoff valve (see Figure

16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Pressure Testing Heater Gas Connections

1. Open manual shutoff valve (see Figure 15). 2. Open propane supply tank valve. 3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to control valve (see Figure 16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 20 through 22 [manually-controlled models] or pages 22 through 24 [thermostatically-controlled models]). Check all other internal joints for leaks. 7. Turn offheater (see To Turn OffGas to Appliance, page 21 [manually-controlled models] or page 24 [thermostatically-controlled models]).
15. Manual Shutoff Valve

Manual • "_ Shutoff ,// Valve

Thermostat Gas Valve or Control Valve Location /

Supply Ta__. __

  • // :_._ -- To;..-=

i i i , i _ i _ i

_ ,L_, ,ff* -,-_, ,

Figure 16. Checking Gas Joints

Show 7 more labels / short text on this page
Shutoff Valve · sed · Figure · Propane · ,,_ · ///, · "/ /
Page 19 of the Desa Tech CGD3930PT user manual — GrateBase<_._.._ , :1 "at -
Page 19 · click to enlarge
Page 19
Desa Tech CGD3930PT — INSTALLING LOGS diagram (page 19)
Fig. 18

INSTALLING LOGS

WARNING

Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do

not modify logs. Only use logs supplied with beater. 1. Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in the grate base behind the burner (see Figure 17). 2. Place the base ofthe middle log (#2) in the U-shaped slots of the grate base in front of the back log. The cutout on the right of the middle log should fit over the burner

(see Figure 18), Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is centered over the burner "U" bend. 3. Locate the recesses on the back of the front log (#3). Fit these recesses between the posts of the grate base (see Figure 19). 4. Locate the notches in the bottom of the crossover log (#4). Place the crossover log on top of the middle log and front log. Make sure the notches of the cross-

over log lines up with rectangular knobs on top of the middle and front logs (see Figure 20).

/_"_Back Log (#1) (_J_j Middle Log (#2)

Peg "(<.:"" -.1.. Hole in _ '- _. _.'.-., _

GrateBase< , :1 "at -

_,,,, " L_'_---%_,_"_% j ' Cut°ut ._./

_I "_"_I U-Shaped _J td Slot

Figure 17- Installing Back Log (#1) Figure 18 - Installing Middle Log (#2)

Front Log (#3) Notches _ Crossover

"_1<_'_ Rectangular _-,_p.,_ f

Flgure19. lnstalllng_Front:;#3) Fl::::. lnstalllng Cr "_o_ver Log (#_

Page 20 of the Desa Tech CGD3930PT user manual — NOTICE
Page 20 · click to enlarge
Page 20
Desa Tech CGD3930PT — OPERATING diagram (page 20)
Fig. 19

OPERATING

1 FOR YOUR SAFETY READ BEFORE LIGHTING /

HEATER.

WARNING

ManuallyControlled Models

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life,

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the

knob will not push in or turn by hand, don't try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING

  • If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.
  • You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE

During initial operation of new heater, burning logs will give off a paper- burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot ff heater has been running.

1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
3. Press in and turn control knob clockwise _ to the OFF position.

IgnitorButlon\ _Control Knob

Figure 21 - Control Knob and Ignitor Button Location

4. Walt five ($) minutes to clear out any gas. Then smell for gas, including near the floor. I!you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.
Page 21 of the Desa Tech CGD3930PT user manual — TO TURN OFF GAS TO APPLIANCE
Page 21 · click to enlarge
Page 21
Desa Tech CGD3930PT — HEATER diagram (page 21)
Fig. 20

OPERATING

5. Slightly depress and turn control knob counterclockwise _ to the PILOT

position. Press in control knob for five (5) seronds (see Page 20).

HEATER

ManuallyControlled Models

6. With control knob pressed in, press and release ignitor button. This will light pfloL The pilot is attached to the burner. If needed, keep pressing ignitor button until pilot lights.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Figure 22 - Pilot

  • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
8. Slightly depress and turn control knob counterclockwise _ to desired heating level The burner should light. Set control knob to any heat level between HI and LO.

WARNING

Do not operate heater between PILOT and HIGH positions.

VARIABLE CONTROL OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in increased heating comfort.

CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

TO TURN OFF GAS TO APPLIANCE

1. Press in and turn control knob clockwise _ to the HIGH position. 2. Turn control knob clockwise _ to the pilot position. 3. Press in control knob and turn clockwise _ to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1. Turn control knob clockwise _ to the HIGH position. 2. Press in and turn control knob clockwise _ to the pilot position.
Show 4 more labels / short text on this page
Pilot Bumer · Shutting Off Heater · Continued U · lo_o_
Page 22 of the Desa Tech CGD3930PT user manual — NOTICE
Page 22 · click to enlarge
Page 22
Desa Tech CGD3930PT — MANUAL LIGHTING PROCEDURE diagram (page 22)
Fig. 21

OPERATING

MANUAL LIGHTING PROCEDURE

HEATER

1. Follow steps 1 through $ under Lighting Instructions, pages 20 and 21. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 on page 21.

OPERATING

  • FOR YOUR SAFETY READ BEFORE LIGHTING

HEATER

WARNING

ThermostaticallyControlled Models

if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot_ follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING

  • If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the

bottom, you must open the vents before operating heater.

  • You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE

During Initial operation of new heater, burning logs will give off a paper- burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot if heater has been running.

Page 23 of the Desa Tech CGD3930PT user manual — CAUTION
Page 23 · click to enlarge
Page 23
Desa Tech CGD3930PT — 3. Turn control knob clockwise _ to the OFF position. . g!LniW diagram (page 23)
Fig. 22 · 3. Turn control knob clockwise _ to the OFF position…

OPERATING

1. STOP! Read the safety information above.

HEATER

2. Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise _ to the OFF position. . g!LniW

ThermostaticallyControlled Models

ignitor Button.__" _ _ _COntrOI KnOb

Figure 23 - Control Knob and Ignitor Button Location

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.
5. Turn control knob counterclockwise _ to the PILOT position. Press in

control knob for five (5) seconds (see above).

  • If control knob does not pop out when released, contact a qualified service

person or gas supplier for repairs.

6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

_

Figure 24 - Pilot

8. Turn control knob counterclockwise _ to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION

  • i Do not try to adjust heating levels by using the manual shutoff.valve.
Show 4 more labels / short text on this page
IgnitorElectrode · Thermocouple_ _ mer · Continued I · 10_04
Page 24 of the Desa Tech CGD3930PT user manual — BURNERS
Page 24 · click to enlarge
Page 24
Desa Tech CGD3930PT — TO TURN OFF GAS TO APPLIANCE " diagram (page 24)
Fig. 23

OPERATING

TO TURN OFF GAS TO APPLIANCE "

HEATER

1. Turn control knob clockwise _ to the OFF position.

ThermostaticallyControlled Models

Shutting Off Burners Only (pilot stays lit)

1. Turn control knob clockwise _ to the PILOT position.

THERMOSTAT CONTROL OPERATION

The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

MANUAL LIGHTING PROCEDURE

1. Follow steps 1 through 5 under Lighting lnstruclions, page 23.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,

release control knob. Now follow step 8, page 23.

INSPECTING

Check pilot flame pattern and burner flame patterns often.

BURNERS

Figure 25 shows a correct pilot flame pattern. Figure 26 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocoupl¢ cools, the heater will shut down.

Figure 25. Correct Pilot Flame Pattern

Figure 26 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 24

  • turn heater off (see To Turn OffGas to Appliance, page 21 [manually-controlled models] or above [thermostat-controlled models])
  • see Troubleshooting, pages 25 through 28
Show 4 more labels / short text on this page
Shutting Off Heater · (Thermostat-Controlled Models Only) · PILOT FLAME PA'I'rERN · Pilot Burner
Page 25 of the Desa Tech CGD3930PT user manual — TO_
Page 25 · click to enlarge
Page 25
Desa Tech CGD3930PT — CLEANING diagram (page 25)
Fig. 24

CLEANING

WARNING

AND MAINTENANCE

Turn off heater and let cool before cleaning.

CAUTION

You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER • Use a vacuum cleaner or small, soft bristled brush to clean.

LOGS

  • If you remove logs for cleaning, refer to Installing Logs, page 19, to properly replace logs.
  • Replace log(s) if broken or chipped (dime-sized or larger).

TROUBLESHOOTING

WARNING

Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

Note: All troubleshooting items are

listed in order of

CAUTION

operation.

'Never use a wire, needle, or similar object to clean ODS/pilot. This

can damage ODS/pilot unit.

OBSERVED POSSIBLE PROBLEM CAUSE REMEDY

When ignitor button ts pressed, there is no

1. Ignitor electrode not conneeted to ignitor cable 2. Ignitor cable pinched or wet
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel. 4. Replace ignitor cable 5. Replace piezo ignitor 6. Replace piezo ignitor 7. Replace pieze igniter
3. Piezo ignitor nut is loose
4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong

TO_

spark at ODS/pilot

Page 26 of the Desa Tech CGD3930PT user manual — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING
Page 26 · click to enlarge
Page 26
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 26)
Fig. 25

OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING

Continued When ignitor button

1. Gas supply turned off or manual shutoff valve closed 2. Control knob not in
1. Turn on gas supply or open manual shutoff valve

is pressed, there is spark at ODS/pilot but no ignition

2. Turn control knob to

PILOT position 3. Control knob not

PILOT position 3. Press in control knob

pressed in while in PILOT position 4. Air in gas lines when installed

while in PILOT position

4. Continue holding down control knob. Repeat

igniting operation until air is removed

5. Depleted gas supply
5. Contact local propane

gas company 6. Clean ODS/pilot (see Cleaning and Mainte- nance, page 25) or

6. ODS/pilot is clogged

replace ODS/pilot assembly 7. Replace gas regulator

7. Gas regulator setting is not correct
1. Control knob not fully
1. Press in control knob

flame goes out when control knob is released

pressed in 2. Control knob not

fully 2. After ODS/pilot lights,

pressed in long enough

keep control knob pressed in 30 seconds 3. Fully open manual shut- off valve

3. Manual shutoff valve

not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to

4. A) Contact local pro-

cool, causing pilot flame to go out. This problem could be caused by one or both of the following:

B) Clean ODS/pilot (see Cleaning and Mainte- nance, page 25) or repl_e ODS/pilot assembly

A) Low gas pressure B) Dirty or partially clogged ODS/pilot

5. Thermocouple connection loose at control valve
5. Hand tighten until snug, then tighten 1/4 mm more
6. Thermocouple damaged
6. Replace thermocouple 7. Replace control valve
7. Control valve damaged

ODS/pilot lights but · pane gas company

Page 27 of the Desa Tech CGD3930PT user manual — 4. Dirty or partially clogged burner orifice
Page 27 · click to enlarge
Page 27
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 27)
Fig. 26

OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING

Continued Burner does light

1. Burner orifice clogged
1. Clean burner (see Cleaning and Maintenance, page 25) or replace burner orifice 2. Contact local propane gas company 3. Replace burner orifice

after ODS/pilot is lit

2. Inlet gas pressure is too low 3. Burner orifice diameter is too small
1. Manifold pressure is too low 2. Burner orifice clogged

Delayed ignition of bumer

1. Contact local natural gas company 2. Clean burner (see Cleaning and Maintenance, page 25) or replace burner orifice
1. Burner orifice is clogged or damaged

Bumer backfiring during combustion

1. Clean burner (see Cleaning and Maintenance, page 25) or replace burner orifice 2. Replace damaged burner 3. Replace gas regulator
2. Damaged burner 3. Gas regulator defective

Slight smoke or odor during initial operation

1. Not enough air
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance, page 25) 2. Replace gas regulator 3. Problem will stop after a few hours of operation
2. Gas regulator defective 3. Residues from manufacturing processes and logs curing

Moisture!condensa- 1. Not enough combus- 1. Refer to Air for Com- tion noticed on tion/ventilation air bustion and Ventilation

windows requirements (page 5)

1. Turn control knob to LO position and let warm up

Heater produces a whistling noise

I.Turningcontrolknob

toHI positionwhen burneriscold 2. Air in gas line

when burner is lit

for a minute 2. Operate burner until air is removed from line. Have gas line checked by local natural gas company 3. Observe minimum installation clearances (see pages 9-12) 4. Clean burner (see Cleaningand Maintenance, page 25) or replace

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice

burner orifice

Page 28 of the Desa Tech CGD3930PT user manual — Gasodorduring combustion
Page 28 · click to enlarge
Page 28
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 28)
Fig. 27

TROUBLE- SHOOTING.

WARNING

  • If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
  • if you cannot reach your gas supplier, call the fire department.

OBSERVED POSSIBLE PROBLEM CAUSE REMEDY

Heater produces a clicking/ticking noise ust after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person

Heater produces unwanted odors

1. Heater burning vapors 1. from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement above) 2. Gas leak. See Warning 2. statement at top of page

Open window and ventilate room. Stop using odor causing products while heater is running

Locate and correct all

leaks (see Checking Gas Connections, page 17)

Heater shuts off in use

1. Not enough fresh air is available 2. Low line pressure
1. Open window and/or door for ventilation 2. Contact local natural gas company 3. Clean ODS/pilot (see Cleaning and Maintenance, page 25)
3. ODS/pilot is partially clogged

Gas odoreven when control knob is in OFF

I. Locate and correct all

1. Gas leak. See Warning statement at top of page 2. Control valve defective

leaks (see Checking Gas Connections, page 17) 2. Replace control valve

Gasodorduring combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all

leaks (see Checking Gas

Logs set cycles m pilot, but room temperature drops to a lower than ideal level

1. Thermostat sensing bulb needs to be repositioned.
1. Reposition thermostat sensing bulb (see instructionsfor Optional Positioning of Thermostat Sensing Bulb, page 29.

before log set comes back on

(ODS operates) · )osition · Connections, page 17)

Page 29 of the Desa Tech CGD3930PT user manual — Factory-built Metal Fireplace
Page 29 · click to enlarge
Page 29
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 29)
Fig. 28

OPTIONAL POSITIONING

If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you maywant to reposition the thermostat sensing bulb.

OF THERMOSTAT SENSING BULB

The thermostat sensing bulb is located near the gas valve assembly on the mounting bracket. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. For positioning the thermostat sensing bulb elsewhere, an adhesive-backed mounting clip has been provided.

Tools needed1/4" hex driver or socket

For Masonry and

l. Remove logs. Locate the gas valve assembly and thermostat sensing bulb (see Figure 27).

Factory-built Metal Fireplace

Mounting Thermostat Bracket Sensing Bulb

Figure 27- Location of Gas Valve Assembly and Thermostat Sensing Bulb

2. The adhesive-backed mounting clip (see Figure 28) is attached to the thermostat sensing bulb. Remove the adhesive-backed mounting clip.

Figure 28 - Adhesive-backed Mounting Clip

3, With 1/4" hex driver or socket, loosen the thermostat screw. Carefully slide the thermo- stat sensing bulb out of the retaining clamp (see Figure 29).

Retaining Claml:

Figure 29 - Removing Thermostat Sensing Bulb

4. The thermostat sensing bulb may be located to the lower fight front sid_ of fireplace. Determine location of sensing bulb, but do not mount sensing bulb until step 5. If you

have a masonry fireplace, see Figure 30 on page 30 for location. Continued I

Show 5 more labels / short text on this page
Gas Valve · Assembly · Screw · Sensing Bulb · ICGd04
Page 30 of the Desa Tech CGD3930PT user manual — J
Page 30 · click to enlarge
Page 30
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 30)
Fig. 29

I-, Thermostat L.

OPTIONAL POSITIONING

OF THERMOSTAT SENSING BULB

Figure 30 - Locating Thermostat Sensing Bulb on Masonry Fireplace

For Masonry and

Factory-built Metal Fireplace

If you have a factory-built metal fireplace, see Figure 31 for location.

J

Figure 31 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace

If your ftreplace has glass doors, position sensing bulb directly behind door gap on right bottom side (see Figure 32).

Figure 32 - Installing Thermostat Sensing Bulb behind Glass Doors

5. The mounting clip must be a minimum of 3"from bottom of fireplace to prevent crimping of capillary. Once you have decided on a location, clean the area thoroughly. Remove the paper backing from the adhesive on back of mounting clip, Press the clip into the new location so that the thermostat

sensing bulb will be positioned vertically with the capillary at the bottom (see Figure 33). Slide the thermostat sensing bulb into the clip.

Adhesive-backed • Mounting Clip

Do Not Crimp Capillary

Figure 33. Positioning the Thermostat Sensing Bulb In the Vertical Position with the Capillary at the Bottom

Show 11 more labels / short text on this page
Sensing Bulb i · Mounting Clip · / kl · Thermostat · Sensing Bulb · Adhesive-backed Mounting Clip · Thermostat · Sensing Bulb · Mounting Clip · Glass Doors · _ Sensing Bulb
Page 31 of the Desa Tech CGD3930PT user manual — HINTS
Page 31 · click to enlarge
Page 31
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 31)
Fig. 30

TECHNICAL

You may have further questions about installation, operation, or ti'oubleshooting. If so, contact DESA International's Technical Service Department at 1-800-DESA LOG (I-800-337-2564).

SERVICE

SPECIFICATIONS

18" Model 24" Models 30" Models

Btu (Variable) 16,000/30,000 20,000/39,000 20,000/39,000

Type Gas Propane Only Propane Only Propane Only

Ignition Piezo Piezo Piezo

Manifold Pressure 8.0" W.C. 8.0" W.C. 8.0" W.C.

Pressure (in. of water) Maximum 14" 14" 14" Minimum* 11" 11" t 1"

30 lbs. 32 lbs.

Shipping Weight 28 Ibs.

* For the purpose of input adjustment

SERVICE

  • When gas pressure is too low
  • pilot will not stay lit
  • burners will have delayed ignition
  • heater will not produce specified heat
  • propane gas supply may be low

HINTS

  • When gas quality is bad
  • pilot will not stay lit
  • burners will produce flames and soot
  • heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

Inlet Gas

Page 32 of the Desa Tech CGD3930PT user manual — PARTS CENTRAL
Page 32 · click to enlarge
Page 32
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 32)
Fig. 31

REPLACEMENT

PARTS

Parts Under Warranty Contact authorized dealers of this product. If they can't supply original replace- ment part(s), call DESA International's Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

When calling DESA International, have ready

  • your name
  • your address
  • model number of your heater
  • how heater was malfunctioning
  • type of gas used (propane or natural gas)
  • purchase date Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty Contact authorized dealers of this product. If they can't supply original replace- ment part(s), call DESA International's Parts Department at 1-800-972-7879 for referral information.

  • When calling DESA International, have ready
  • model number of your heater
  • the replacement part number

PARTS CENTRAL

These Parts Centrals are privately owned businesses. They have agreed to support our customer's needs by providing original replacement parts and accessories.

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department

Washer Equipment Co. 1715 Main Street Kansas City, Me 64108 KS, Me, AR 816-842-3911

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426

East Coast Energy Products 833 Broadway W. Long Branch, N,J 07764 906-870-8809 1-800-755-8809

Hal¢o Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 215-696-2670 1-800-368-0803

342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951

FBD 1349 AdamsStreet BowlingGreen, KY 42103 502-846-8534 1-800-654-8534 Fax: 1-800-846-0090

Tarantln Tank Co. • P.O. Box6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724

LA Porte's Parts & Service 2444 N. 5th Street HartsvUle, SC 29550 803-332-0191 Parts Department

Albany Ladder 1586-90 Central Avenue Albany, NY 12205 NY, MA, V'I" 518-869-5335 1-800-354-7368

Four Rags Power Products 1115 Stateline Road Niles, MI 49120 616-684-2697 Parts Only

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States

Master Service Center 1184 Wilson NW Walker, MI 49504 616-791-4760 1-800446-1446

Portable Heater Parts · 803-879-3009 1-800-845-5301 · 103d04

Page 33 of the Desa Tech CGD3930PT user manual — 10_Q04
Page 33 · click to enlarge
Page 33
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 33)
Fig. 32

ACCESSORIES

Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International's Sales Department at 1-'800-472-7879

for referral information. You can also write to the address listed on the back page of this manual.

MANUAL SHUTOFF VALVE - GA5010 For all models. Manual shutoff valve

with 1/8" NPT tap, Fits 112" NPT pipe.

BLACK FIREPLACE HOOD - GA6050 For all models. Helps deflect heat away from mantel or wall above fireplace.

BRASS FIREPLACE HOOD - GA6052

For all models. Helps deflect heat away from mantel or wall above

fireplace.

DAMPER CLAMP - GA6080

For variably controlled models. Permanently opens chimney flue damper for vented operation (see Installing Damper Clamp Accessory for Vented Operation, page 13).

LAVA ROCK - GA6060 For all models. Order when additional

rock is desired. (3 lb. bag)

10_Q04

Page 34 of the Desa Tech CGD3930PT user manual — Variable ManuallyControlled Models
Page 34 · click to enlarge
Page 34
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 34)
Fig. 33

ILLUSTRATED

PARTS BREAKDOWN

Variable ManuallyControlled Models

CGD3018P CGD3924P CGD3930P

/o3eo4

Page 35 of the Desa Tech CGD3930PT user manual — 100639-01 101449-04 101137-02 101416-33 GA6060
Page 35 · click to enlarge
Page 35
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 35)
Fig. 34

PARTS LIST This list contains replaceable parts usedin your heater. When ordering parts, follow

the instructions listed under Replacement Parts on page 32 of this manual.

CGD3018P CGD3924P CGD3930P PART NUMBER PART NUMBER PART NUMBER DESCRIPTION KEY NO.

QTY.

1 103008-02 2 103009-02 3 103010-02 4 103011-02 5 102775-04CK 6 102844-02 7 102966-02 8 098887-10 9 102798-01 10 102779-04 11 099056-19 12 102843-01 13 102980-01 14 102568-08 18 098508-01

Back Log (#1) 1

Middle Log (#2) 1 Front Log (#3) 1 Crossover Log (#4) 1 Painted Base Assembly 1 Lower Bracket 1

103011-01 102775-01CK 102844-01 102966-01 098867-10 102798-01 102779-02 099056-17 102843-01 102772-01 102568-06 098508-01 098354-01 102445-01 099387-08 098271-07 099059-02 098594-01 098593-01 Ml1084-38 098276-01 098249-01

103011-03 102775-03CK 102844-01 102966-01 098867-10 102798-01 102779-02 099056-17 102843-01 102772-01 102568-06 098508-01

Gas Regulator 1 Inlet Tube 1 Outlet Burner Tube 1

Burner Orifice Injector 1 Burner Clip 1 Burner 1 Control Valve 1 Valve Retainer Nut 1 Control Knob 1

16 098354-01 17 102445-01 18 099387-08 19 098271-07 20 099059-02 20-1 098594-01 20-2 098593-01 21 Ml1084-38 22 098276-01 23 098248-01

098354-01 102445-01 099387-08 098271-07 099059-02 098594-01 098893-01 Ml1084-38 098276-01 098249-01

Piezo Ignitor 1 Pilot Tube 1

Ignitor Cable 1 ODS Pilot 1

Ignitor Electrode 1 Thermocouple 1 Hex Screw, #8-18 x .38 11 Hex Head Plug, 1/8 NPT 1 Nut, M5 2

PARTS AVAILABLE -- NOT SHOWN

100563-01 101055-02 100565-01 100639-01 101449-04 101137-02 101416-33

100563-01 101055-02 100565-01 100639-01 101449-04 101137-02

100639-01 101449-04 101137-02 101416-33 GA6060

101415-33 GA6060

GA6060

Show 4 more labels / short text on this page
103005-01 103009-01 103010-01 · 103008-03 103009-03 103010-03 · Upper Bracket 1 · 100563-01 101055-02 100565-01
Page 36 of the Desa Tech CGD3930PT user manual — A
Page 36 · click to enlarge
Page 36
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 36)
Fig. 35

ILLUSTRATED

PARTS BREAKDOWN

ThermostaticallyControlled Models

CGD3924PT CGD3930PT

A

20-1 20 · _t 14 \

Page 37 of the Desa Tech CGD3930PT user manual — PARTS AVAILABLE -- NOT SHOWN
Page 37 · click to enlarge
Page 37
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 37)
Fig. 36

PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 32 of this manual.

KEY CGD3924PT CGD3930PT NO. PART NUMBER PART NUMBER DESCRIPTION

QTY.

1 103008-01 2 103009-01 3 103010-01 4 103011-01

103008-03 103009-03 103010-03 103011-03 102775-07CK 102844-01 102966-01 098867-10

Back Log (#1) Middle Log (#2) Front Log (#3) Crossover Log (#4)

1 1 1 1

5 102775-05CK 6 102844-01 7 102966-01

Painted Base Assembly Lower Bracket

Upper Bracket Gas Regulator inlet Tube Outlet Burner Tube

6 098867-10 9 102981-01 10 1102983-02 11 099066-17

12 102843-01 13 102772-01 14 101329-19

101329-19 102979-01 098544-01 102445-01 099387-09 098271-07 099059-02 098594-0! 098593-01 Ml1084-38 098249-01 099211-01

Thermostat Gas Valve Assembly Thermostat Bracket

15 102979-01 16 098544-01 17 102445-01 18 099387-09

1 1 1 15

Thermobulb Clip Piezo Ignitor Pilot Tube

19 098271-07 20 099059-02 20-1 i098594-01 20-2 098593-01 21 Ml1084-38 22 096249-01 23 099211-01

Ignitor Cable ODS Pilot

Ignitor Electrode Thermocouple Hex Screw, #8-18 x .38 Nut, M5 Hex Screw, 10-16 x 2.50

PARTS AVAILABLE -- NOT SHOWN

100563-01 101054-01 100565-01 100639-01 101137-02 101416-33 GA6060

100563-01 101054-01 100565-01 100639-01 101137-02 101416-33 GA6060

Hardware Kit Information Video Lava Rock

Show 7 more labels / short text on this page
102981-01 102983-02 · 099056-17 102843-01 102772-01 · Burner Orifice Injector · Bumer Clip Burner · t · Waming Plate · Lighting Instructions Plate
Page 38 of the Desa Tech CGD3930PT user manual — NOTES
Page 38 · click to enlarge
Page 38
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 38)
Fig. 37

NOTES

f 0,,_o4

Page 39 of the Desa Tech CGD3930PT user manual — NOTES
Page 39 · click to enlarge
Page 39
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 39)
Fig. 38

NOTES

Page 40 of the Desa Tech CGD3930PT user manual — INTERNATIONAL
Page 40 · click to enlarge
Page 40
Desa Tech CGD3930PT — OBSERVED POSSIBLE PROBLEM CAUSE REMEDY TROUBLESHOOTING diagram (page 40)
Fig. 39

WARRANTY INFORMATION

KEEP THIS WARRANTY

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY

COMFORT GLOW VENT-FREE PROPANE GAS LOG HEATERS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all loca! codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or

become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MER- CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL'S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES,

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty wrim:

DESA

INTERNATIONAL

2701 Industrial Ddve P.O. Box 90004 Bowling Green, KY 42102-9004

103604-01 Rev. A 5/97

Model · Date Purchased

Ask about the Desa Tech CGD3930PT

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech CGD3930PT

Be the first to ask — other owners or our team will answer.