vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Save this manual for future reference. Save this manual for future reference.



Control Knob & Ignitor Button (not seen from this view)

Figure 1 - Vent-Free Gas Heater
LOCAL CODES
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
Thermostat models have a thermostat sensing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com
Grill Guard · Glass Panel


Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6x10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable win- dows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 6.
If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Heater Loca- tion, page 5.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


AIR FOR COMBUSTION AND VENTILATION Determining Fresh-Air Flow For Heater Location
Btu/Hr (maximum the space can support)
Btu/Hr (actual amount of Btu/Hr used)
Use this work sheet to determine if you have a confined or unconfined space.
60,000 Btu/Hr (actual amount of Btu/Hr used)
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
Length x Width x Height = cu. ft. (volume of space)
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.
Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.
B. Vent room directly to the outdoors. See Ventilation Air From Out- doors, page 6.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
(volume of space) x 20 = (Maximum Btu/Hr the space
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)

Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws com- bustion air from the outdoors and vents to the outdoors.
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com
can support) · 40,000 20,000 60,000

AIR FOR COMBUSTION AND VENTILATION Continued
VENTILATION AIR
Ventilation Air From Inside Building
Ventilation Grills Into Adjoining Room,
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Or Remove Door into Adjoining
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 2 - Ventilation Air from Inside Building

Figure 3 - Ventilation Air from Outdoors
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com



NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.
CEILING
Minimum From Sides Of Heater
Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional CSA design-certified equipment shutoff valve can be purchased from your dealer. See Accessories, page 24.
Figure 4 - Mounting Clearances As Viewed From Front of Heater
You can locate heater on the floor, away from a wall. A wall mounting bracket and floor base stand are included with this heater. Determine which method is best for your application.
An optional fan kit is available from your dealer. See Accessories, page 24. If planning to use fan, locate heater near an electrical outlet.
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


Removing Front Panel Of Heater 1. Remove the four painted screws, two on each side of front panel. 2. Pull bottom of front panel forward, then out. 3. Remove any remaining packaging materials.
The thermostat sensing bulb has been placed inside the heater for protection during shipping.
Locating Thermostat Sensing Bulb (for thermostat applications) 1. Remove front panel of heater (see Figure 7). 2. Locate thermostat sensing bulb just under burner assembly.

Attaching Thermostat Sensing Bulb 1. Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater. 2. Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hardware package. 3. Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.

Figure 7 - Removing Front Panel Of Heater
Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 14 inches apart from their centers. Attach mounting bracket to wall in one of two ways: 1. Attaching to wall stud 2. Attaching to wall anchor
Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.
Figure 5 - Attaching Thermostat Sensing Bulb
Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).
Mounting Bracket
Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.
Locate mounting bracket in heater carton. Remove mounting bracket from heater carton.
Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.
Figure 6 - Mounting Bracket
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com
Thermostat Sensing Bulb · Clamp


Attaching To Wall Anchor Method
For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2. Fold wall anchor as shown in Figure 9. 3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. 5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is firmly fastened to wall.


Placing Heater On Mounting Bracket 1. Locate two horizontal slots on back panel of heater. 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.
Figure 9 - Folding Anchor Figure 10 - Popping Open Anchor Wings For Thin Walls
Figure 8 - Mounting Bracket Clearances

Attaching To Wall Stud Method
Mounting Bracket (attached to wall)
For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64" drill bit. 2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall. 3. Insert mounting screws through bracket and into wall studs. 4. Tighten screws until mounting bracket is firmly fastened to wall studs.
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


Installing Heater To Wall (Cont.) Mounting Heater To Floor
Installing Bottom Mounting Screws 1. Locate two bottom mounting holes. These holes are near bot- tom on back panel of heater (see Figure 12). 2. Mark screw locations on wall. 3. Remove heater from mounting bracket. 4. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching To Wall Anchor Method, page 9. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacers between bottom mounting holes and wall anchor or drilled hole. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole. 8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 11 and 12).
Mounting Base Feet to Heater 1. Lay heater cabinet on its back on a table with the heater bot- tom overhanging the table edge. 2. Align holes in base foot with mounting holes on bottom of cabinet (see Figure 13). 3. Secure base foot to heater using sheet metal screws. 4. Repeat for other side.
Mounting Base Feet to Floor (Where required by local code) 1. Remove front cover (see Removing Front Panel of Heater, page 8). 2. Position heater with base feet in desired location. Mark holes for drilling. Remove heater with base. 3. For carpeted floors, make a small cut with a sharp knife at marked locations prior to drilling. If mounting base to a wood floor, drill 1/8 inch diameter hole, 3/4 inch deep. (Do not use anchors in wood floors). If mounting base to a concrete floor, drill with 1/4 inch diam- eter concrete drill bit, 13/8 inches into floor. Insert anchors com- pletely into holes. 4. Reposition heater with base feet over holes. Secure base to floor with wood screws. See Figure 13.
Figure 12 - Installing Bottom Mounting Screws
Figure 13 - Installing Base Feet
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


Typical Inlet Pipe Diameters
20,000 Btu/Hr Models - 3/8" or greater

30,000 Btu/Hr Models - 1/2" or greater
Installation must include equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 15).
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Install sediment trap in supply line as shown in Figure 15. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

For propane/LP gas, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install the external regulator with the vent pointing down as shown in Figure 14. Pointing the vent down protects it from freezing rain or sleet.


Natural Gas From Gas Meter (5" W.C. to 10.5" W.C. Pressure)
Figure 14 - External Regulator With Vent Pointing Down
Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure)
Figure 15 - Gas Connection
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 24.
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com
Test Gauge Connection* · Sediment Trap


Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 16). 2. For natural gas open main gas valve located on or near gas meter. For propane/LP gas open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to thermostat gas valve (see Figure 17 or 18). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, page 13). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 14). 8. Replace front panel.


Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (con- trol valve) and equipment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using com- pressed air. 4. Check all joints of gas supply piping system. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.
Figure 17 - Checking Gas Joints for Natural Gas
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 16). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using com- pressed air. 3. Check all joints from gas meter for natural gas (see Figure 17) or propane/LP supply tank for propane/LP gas, to equipment shutoff valve (see Figure 18). Apply a noncorrosive leak de- tection fluid to all joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Figure 18 - Checking Gas Joints for Propane/LP Gas
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


OPERATING HEATER

Ignitor Button Control Knob
LO
PILOT
OFF
HI
IGNITOR
1. STOP! Read the safety information above. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Fig- ure 19).
Figure 19 - Control Knob In The OFF Position

Figure 20 - Pilot (actual pilot may vary)
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com
Thermocouple


To Turn Off Gas To Appliance Thermostat Control Manual Lighting Procedure INSPECTING HEATER
INSPECTING HEATER
Check pilot flame pattern and burner flame pattern often.
TO TURN OFF GAS
TO APPLIANCE
Figure 21 shows a correct pilot flame pattern. Figure 22 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed.
Turn control knob clockwise to the PILOT position.

The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Selecting the HI setting will cause the burner to remain fully on without modulating down in most cases.
PROCEDURE
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


ODS/PILOT AND BURNER • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.
CLEANING BURNER PILOT AIR INLET

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot for dust and dirt. 3. Blow air through the ports/slots and holes in the burner. 4. Never insert objects into the pilot tube.
Figure 23 shows a correct burner flame pattern. Figure 24 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.
1/2 Glass Height
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet about two inches from where the pilot flame comes out of the pilot assembly (see Figure 25). With the unit off, lightly blow air through the air inlet. You may blow through a drinking straw if compressed air is not available.
Figure 23 - Correct Burner Flame Pattern
1/2 Glass Height

Figure 24 - Incorrect Burner Flame Pattern

Figure 25 - Pilot Inlet Air (Propane/LP Pilot Shown)
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com
Blue Flame · Yellow Tipping


Btu (Variable) 10,000/20,000 15,000/30,000 Type Gas Natural Only Natural Only Ignition Piezo Piezo Pressure Regulator Setting 3" W.C. 3" W.C. Inlet Gas Pressure (in. of water)
Maximum 10.5" 10.5" Minimum 4" 4" Dimensions, Inches (H x W x D)
Heater (Includes knobs & grill) 26.25 x 18.25 x 7 26.25 x 25.75 x 7 Carton 28.25 x 21.25 x 9 28.25 x 29 x 9 Weight (pounds)
Heater 20 28 Shipping 25 33
Btu (Variable) 10,000/20,000 15,000/30,000 Type Gas Propane/LP Only Propane/LP Only Ignition Piezo Piezo Pressure Regulator Setting 8" W.C. 8" W.C. Inlet Gas Pressure (in. of water)
Maximum 14" 14" Minimum 11" 11" Dimensions, Inches (H x W x D)
Heater (Includes knobs & grill) 26.25 x 18.25 x 7 26.25 x 25.75 x 7 Carton 28.25 x 21.25 x 9 28.25 x 29 x 9 Weight (pounds)
Heater 20 28 Shipping 25 33
TECHNICAL SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.
You can also visit DESA International’s technical service web site at www.desatech.com
You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier. SERVICE PUBLICATIONS
You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


TROUBLESHOOTING WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see Cleaning and Maintenance, page 15) or replace ODS/ pilot assembly
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
Delayed ignition of burner
Burner backfiring during combustion
Yellow flame during burner combustion
Slight smoke or odor during initial operation
Heater produces a whistling noise when burner is lit
White powder residue forming within burner box or on adjacent walls or furniture
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com



POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise just after burner is lit or shut off
Heater produces unwanted odors

Gas odor even when control knob is in OFF position
Gas odor during combustion
Moisture/condensation noticed on windows
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.
KEY PART NUMBER FOR NO. CBN20 CBP20 DESCRIPTION QTY.
1 097159-04 097159-04 Piezo Ignitor 1 2 107954-01 107954-01 Front Panel 1 3 107879-02 107879-02 Grill Guard 1 4 1110038-03 110038-04 Control Valve 1 5 107677-01 107677-01 Glass Retainer 2 6 098260-12 098260-12 Glass 1 7 ** ** Cabinet 1 8 107894-08 107894-08 Deflector Assembly 1 9 098271-09 098271-09 Ignitor Cable 1 10 098249-01 098249-01 Nut, M5 2 11 110803-01 110803-02 ODS/Pilot Assembly 1 110186-01 110186-01 Thermocouple Kit 1 12 103446-01 103446-01 Burner 1 13 099387-05 099387-05 3/16" Pilot Tubing 1 14 103845-06 103845-05 Injector 1 15 099066-02 099066-02 Mounting Bracket 1 16 099415-17 099415-18 Gas Regulator 1 17 Hex Nut 1 18 103570-04 103570-04 3/8" Outlet Tubing 1 19 103572-03 103572-03 3/8" Inlet Tubing 1 20 098508-01 098508-01 Valve Retainer Nut 1 21 098354-02 098354-02 Control Knob 1 22 109303-04 109303-04 Baffle 1
100642-03 100642-03 Hardware Assembly 1 105345-01 105345-01 Cable Tie 1 107888-01 107888-01 Control Position Label 1 109483-01 109483-01 Lighting Instruction Plate 1 GA4550 GA4550 Base Kit 1
** Not a field replaceable part.
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com



107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.
KEY PART NUMBER FOR NO. CBN20T CBP20T CBN30T CBP30T DESCRIPTION QTY.
1 097159-04 Piezo Ignitor 1 2 107954-01 107954-01 107955-01 107955-01 Front Panel 1 3 107879-02 107879-02 107879-01 107879-01 Grill Guard 1 4 098522-10 098522-11 098522-12 098522-13 Thermostat Gas Valve 1 5 107677-01 Glass Retainer 2 6 098260-12 098260-12 098260-13 098260-13 Glass 1 7 ** Cabinet 1 8 107894-08 107894-08 107894-09 107894-09 Deflector Assembly 1 9 098271-09 Ignitor Cable 1 10 098249-01 Nut, M5 2 11 110803-01 110803-02 110803-01 110803-02 ODS/Pilot Assembly 1 110186-01 Thermocouple Kit 1 12 103446-01 103446-01 103447-01 103447-01 Burner 1 13 099387-03 3/16" Pilot Tubing 1 14 103845-06 103845-05 103845-08 103845-07 Injector 1 15 099066-02 Mounting Bracket 1 16 099415-17 099415-18 099415-17 099415-18 Gas Regulator 1 17 NJF 8C NJF 8C NJF 8C NJF 8C Hex Nut 1 18 103255-02 3/8" Outlet Tubing 1 19 103256-02 3/8" Inlet Tubing 1 20 109303-04 109303-04 109303-03 109303-03 Baffle 1
100642-03 Hardware Assembly 1 105345-01 Cable Tie 1 107888-01 Control Position Label 1 109483-01 Lighting Instruction Plate 1 GA4550 Base Kit 1
** Not a field replaceable part.
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


ACCESSORIES
Purchase these heater accessories from your local dealer. If they can not supply these accessories, either contact your nearest Parts Central (see page 27) or call DESA International at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040.
For all models. Equipment shutoff valve with 1/8" NPT tap.
Usually, we will ask you to return the part to the factory.

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Cen- tral (see page 27) or call DESA International at 1-866-672-6040 for referral information.
FAN KITS - GA3250T For all models. Provides better heat distribution. Makes heater more efficient. Complete installation and operating instructions included. Thermostatically-controlled, blower turns itself on and off as required.
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner’s Registration Form and mail to the address on the back of this owner’s manual. Please provide the following product information:
Date Purchased: Note: Keep receipt for warranty verification.
Serial Number: 7 or 9 digit number located on product or identification tag.
Address:
E-Mail:
Please answer the following questions to register your product with DESA International:
❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other
❍ 100,000 to 250,000 ❍ Over 250,000
❍ Fireplace or Hearth Shop ❍ Farm Store ❍ Other
❍ Emergency Back-Up Heat ❍ Heater was on Sale ❍ Energy Savings/High Efficiency ❍ Construction Project ❍ Other
❍ $50,000 to $74,999 ❍ $75,000 to $99,999 ❍ $100,000 and Over
Not Important Somewhat Important Very Important
Thermostat, Remote, or Manual Operation
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com


2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com
Postage Required


These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Baltimore Electric 5 Manila Ave Hamden, CT 06514-0322 1-800-397-7553 203-248-7553
Master Parts Dist. 1251 Mound Ave. NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 www.nbmc.com
Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717 1-800-368-0803 www.halcoenterprises.com
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 219-462-7441 1-888-619-7060 www.portableheaterparts.com sales@portableheaterparts.com techservice@portableheaterparts.com
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com
Laporte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 843-332-0191 Parts Department
Cans Unlimited P.O. Box 645 Taylor, SC 29687-0013 803-879-3009 1-800-845-5301 cuisales@aol.com
East Coast Energy 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep
FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 937-258-3721 OHIO only 1-800-762-3426
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com



Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
107882-01 Rev. E 09/02
107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com