Procom Vent-Free Blue Flame Heater (ML100HPA)

23 pages·1.4 MB·Electric Heater·PDF·ENDEFRITNLJA
Procom Vent-Free Blue Flame Heater (ML100HPA)
Table of Contents 54 sections INFRARED VENT-FREE · PROPANE/LP GAS · SPACE HEATER · OWNER ’ S OPERATION AND INSTALLATION MANUAL · … ShowHide
Page 2 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — WARNINGS
Page 2 · click to enlarge
Page 2

IMPORTANT SAFETY INFORMATION

In the state of Massachusetts, unvented propane or nature gas-fired space heaters shall be prohibited in bedrooms and bathrooms.

10. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 11. Do not use heater if any part has been under water.

WARNINGS

1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outside. 3. If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas sup plier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. 4. Always run heater with control knob at LOW or HIGH locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result. 5. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensor (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Fresh Air for Combustion and Ventilation pages 4 and 5. 6. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion. 7. If heater shuts off. Do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced. 8. Do not operate heater where flammable liquids or va- pors are used or stored under dusty conditions 9. Do not install models ML100HPA and ML100TPA in a bathroom.

Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 12. Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. 13. Operating heater above elevations of 4,500 feet could cause pilot outage. 14. To prevent performance, problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Due to high temperatures, heater should be kept out of traffic and away from furniture and draperies.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut down. Allow surface to cool before touching.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more af- fected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Propane/LP Gas: Propane/LP gas is odorless. An odor-making agent is added to Propane/LP gas. The o d o r h e l p s y o u d e t e c t a Propane/LP gas leak . However, the odor added to Propane/LP gas can fade. Propane/LP gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

Carefully supervise young children when they are in the same room with heater.

Make sure grill guard is in place before running the heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

State of Massachusetts: The installation must be made by a li- censed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natu- ral gas-fired supplemental room heat- ers shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Page 3 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Page 3 · click to enlarge
Page 3

PRODUCT IDENTIFICATION

Procom Vent-Free Blue Flame Heater (ML100HPA) — PRODUCT IDENTIFICATION diagram (page 3)
Fig. 1

Figure 1- Vent-Free Propane/LP Gas Heater

SAFETY DEVICE A standard requirement for all vent-free room heaters. This heater has a pilot with an Oxygen Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air.

LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas code ANSZ223.1, also known as NFPA 54*. *Available from : American National Standards Institute, Inc.

PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.

THERMOSTATIC HEAT CONTROL ON THERMOSTAT MODELS These heaters have a control valve with a thermostat sensing bulb. This results in the greatest heater comfort and may result in lower gas bills.

UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged. promptly inform dealer where you bought heater.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion.An unvented room heater productes approximately one (1) ounce (30ml) of wter for every 1,000 BTU’s (.3KW’s) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house) .In most supplemental heat application, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experience during cold weather.

The following steps will help insure that water vapor does not become a problem. 1. Be sure the heater is sized properly for the application, including ample combusion air and circulation air. 2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air. 3. Do not use an unvented room heater as the primary heat source.

Batterymarch Park · Quincy, MA 02269

Page 4 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — PROVIDING ADEQUATE VENTILATION
Page 4 · click to enlarge
Page 4

Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction. you must provide additional fresh air. Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6×10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around win- dow and door frames, between sole plates and floors, between wall- ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air from Outdoors, pages 5 and 6. If your home does not meet all of the three criteria above see Determining Fresh-Air Flow for Heater Location, page 4, 5.

Confined and Unconfined Space The National Fuel Gas Code ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour ( 4 . 8 m 3 p e r k w ) o f t h e aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with t h e s p a c e i n w h i c h t h e appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space. This heater shall not be installed in a confined space or unusually t i g h t c o n s t r u c t i o n u n l e s s provisions are provided for adequate combustion and ventilation air. * A d j o i n i n g r o o m s a r e communicating only if there are d o o r l e s s p a s s a g e w a y s o r ventilation grills between them.

FRESH AIR FOR COMBUSTION AND VENTILATION

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Section 5.3. Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if you have a Confined or Unconfined Space* Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length×width×height). Length×Width×Height= cu.ft. (volume of space) Example: Space size 18ft (length)×16ft( width)×8ft. (ceiling height)=2304cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space)÷50 cu. ft.=(Maximum Btu/Hr the space can support)

Example: 2304 cu. ft. (volume of space)÷50 cu.ft.=46.1 or 46,100(maximum Btu/Hr the space can support)

Page 5 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — FRESH AIR FOR COMBUSTION AND VENTILATION
Page 5 · click to enlarge
Page 5

3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas Fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr *Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used. Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 46,100 Btu/Hr(maximum the space can support) 50,000 Btu/Hr(actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From inside Building, page 5. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6 . C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

Example: Gas water heater 40,000 Btu/Hr Vent free heater + 10,000 Btu/Hr Total = 50,000 Btu/Hr

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1. Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts

Procom Vent-Free Blue Flame Heater (ML100HPA) — FRESH AIR FOR COMBUSTION AND VENTILATION diagram (page 5)
Fig. 2

Figure 2 -Ventilation Air from Inside Building

Page 6 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — INSTALLATION
Page 6 · click to enlarge
Page 6

VENTILATION AIR

Procom Vent-Free Blue Flame Heater (ML100HPA) — VENTILATION AIR diagram (page 6)
Fig. 3

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3. Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Figure 3 -Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design certified equipment shutoff valve from your dealer. See Accessories, page 17.

LOCATING HEATER This heater is designed to be mounted on a wall. For convenience and efficiency, install heater where there is easy access for operation, inspection, and service in coldest part of room

When the heater is installed in

Bathrooms,do not use flammable products such as aerosol hair spray,

foot spary or any product that contains flammable vapors and keep towels

away from heater.(only ML060HPA is allowed in a bathroom.)

CHECK GAS TYPE Use only Propane/LP gas. If your gas supply is not Propane/LP, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION NEEDS Before installing heater, make sure you have the items listed below. piping (check local codes) sealant (resistant to Propane/LP gas) equipment shutoff valve* ground joint union test gauge connection* sediment trap tee joint pipe wrench

Page 7 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — INSTALLATION
Page 7 · click to enlarge
Page 7

INSTALLATION

Removing Lower Front Panel Of Heater 1. Remove two Screws near bottom corners of lower front panel. 2. Pull bottom of lower front panel forward, then down (see Figure 6).

Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Procom Vent-Free Blue Flame Heater (ML100HPA) — INSTALLATION diagram (page 7)
Fig. 4

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Procom Vent-Free Blue Flame Heater (ML100HPA) — INSTALLATION diagram (page 7)
Fig. 5

Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

Figure 6 - Removing Lower Front Panel Of Heater

Figure 4 -Mounting clearances As Viewed From Front of Heater

2. Mark screw locations on wall. (see Figure 7) Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall.

FASTENING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater (see Figure 5). It has been taped there for shipping. remove mounting bracket from back panel.

Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall. Attach mounting bracket to wall only in one of two ways: 1. Attaching to wall stud 2. Attaching to wall anchor Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Procom Vent-Free Blue Flame Heater (ML100HPA) — INSTALLATION diagram (page 7)
Fig. 6
Procom Vent-Free Blue Flame Heater (ML100HPA) — INSTALLATION diagram (page 7)
Fig. 7

Figure 5 -Mounting Bracket Location

Figure 7 - Mounting Bracket Clearances

Page 8 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — INSTALLATION
Page 8 · click to enlarge
Page 8

INSTALLATION

Installing Bottom Mounting Screw 1. Locate bottom mounting hole. This hole is near bottom on back panel of healer (see Figure 11). 2. Mark screw location on wall. 3. Remove heater from mounting bracket.

Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64" drill bit. 2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall. 3. Insert mounting screws through bracket and into wall studs. 4. Tighten screws until mounting bracket is firmly fastened to wall studs. Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2. Fold wall anchor as shown in Figure 8 below.

Procom Vent-Free Blue Flame Heater (ML100HPA) — INSTALLATION diagram (page 8)
Fig. 8

Figure 9 - Popping Open Anchor Wing For Thin Walls

5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is firmly fastened to wall.
Procom Vent-Free Blue Flame Heater (ML100HPA) — INSTALLATION diagram (page 8)
Fig. 9

Figure 11 - Installing Bottom Mouting Screw

4. If installing bottom mounting screw into hollow or solid wall,

install wall anchors. Follow steps 1 through 4 under Attaching To Wall Anchor Method. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacers between bottom mounting holes and wall anchor or drilled holes. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled holes . 8. Tighten both screw until heater i s f i r m l y s e c u r e d t o wall. Do not over tighten. Note: Do not replace lower front panel at this time. Replace lower front panel after making gas connections and checking for leaks(see page 9) .

Placing Heater On Mounting

Bracket 1. Locate two horizontal slots on back panel of heater (see Figure 10). 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Procom Vent-Free Blue Flame Heater (ML100HPA) — INSTALLATION diagram (page 8)
Fig. 10
Procom Vent-Free Blue Flame Heater (ML100HPA) — INSTALLATION diagram (page 8)
Fig. 11

Figure 8 - Folding Anchor

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. 4. For thin walls (1/2 " or less), insert red key into wall anchor. Push red key to " pop " open anchor wings (see Figure 9).

Figure 10 - Mounting Heater Onto Mounting Bracket

Page 9 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — CONNECTING TO GAS SUPPLY
Page 9 · click to enlarge
Page 9

INSTALLATION

CONNECTING TO GAS SUPPLY

Procom Vent-Free Blue Flame Heater (ML100HPA) — CONNECTING TO GAS SUPPLY diagram (page 9)
Fig. 12

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 12. Pointing the vent down protects it from freezing rain or sleet.

Figure 13 -Gas Connection

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessories, page 17.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Procom Vent-Free Blue Flame Heater (ML100HPA) — CONNECTING TO GAS SUPPLY diagram (page 9)
Fig. 13

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly. IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

Typical Inlet Pipe Diameters All models up to 20,000 BTU’s use 3/8’’ or greater pipe; All models 25,000 BTU’s and higher, use 1/2” or greater pipe. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

Figure 12 - External Regulator with Vent Pointing Down

Page 10 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — WHAT TO DO IF YOU SMELL GAS
Page 10 · click to enlarge
Page 10

INSTALLATION

OPERATING YOUR HEATER

CHECKING GAS CONNECTIONS

Pressure Testing Heater Gas Connections

FOR YOUR SAFETY READ BEFORE LIGHTING

1. Open equipment shutoff valve (see Figure 14). 2. Open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 15 ). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 10,11and 12) Check the rest of the internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, pages 11 and

A When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor .

Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 K Pa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.

12). 8. Replace lower front panel.

Procom Vent-Free Blue Flame Heater (ML100HPA) — WHAT TO DO IF YOU SMELL GAS diagram (page 10)
Fig. 14

Figure 14 -Equipment Shutoff Valve

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Figure 15 -Checking Gas Joints

Procom Vent-Free Blue Flame Heater (ML100HPA) — WHAT TO DO IF YOU SMELL GAS diagram (page 10)
Fig. 15

reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 K Pa) 1. Close equipment shutoff valve (see Figure 14). 2. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 3. Check all joints from propane/LP supply tank to equipment shutoff valve (see Figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Page 11 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — PROCEDURE
Page 11 · click to enlarge
Page 11

OPERATING YOUR HEATER

Manual Control Models:

TO SELECT HEATING LEVEL

Procom Vent-Free Blue Flame Heater (ML100HPA) — OPERATING YOUR HEATER diagram (page 11)
Fig. 16

ML060HPA,ML100HPA

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information on the side of heater. 2. Check that gas supply to heater is on. 3. Push in gas control knob slightly and turn clockwise

Figure 19 - Burner Patterns

to the OFF position. ( see Figures 16 & 17) 4. Wait five (5) minutes to clear out any air. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on the side of the heater. If you do not smell gas, go to the next step. 5. Push in gas control knob s l i g h t l y a n d t u r n counterclockwise

Procom Vent-Free Blue Flame Heater (ML100HPA) —  LIGHTING  INSTRUCTIONS diagram (page 11)
Fig. 17

Slightly press in control knob and turn counterclockwise to the ON, LOW or HIGH positions(see Figure 19 & 20).

Figure 20 - Burner Patterns

to “PILOT/IGN” and depress for five(5) seconds

Procom Vent-Free Blue Flame Heater (ML100HPA) —  LIGHTING  INSTRUCTIONS diagram (page 11)
Fig. 18

TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Turn control knob clockwise

NOTE: The first time that the heater is operated after connecting the gas supply , the control knob should be depressed for about thirty (30) seconds. This will allow air to bleed from the gas system. 6. With control knob pressed in, push down and release the ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights. 7. Keep control knob depressed for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 5,6 and 7. 8. To select the desired heating level, partially press down the control knob slightly and rotate counterclockwise . Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position. Do not operate between locked positions.

to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (Pilot Stays Lit) Turn control knob clockwise

Figure 16 - Control Knob In The OFF Position

Procom Vent-Free Blue Flame Heater (ML100HPA) —  LIGHTING  INSTRUCTIONS diagram (page 11)
Fig. 19

to the PILOT/IGN position.

MANUAL LIGHTING

PROCEDURE

Figure 17 - Control Knob In The OFF Position

1. Remove lower front panel (see Figure 7 page 7). 2. Follow steps through 5 under Lighting Instructions . 3. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.Follow step 8 under Lighting Instuctions . 5. Replace lower front panel.
Procom Vent-Free Blue Flame Heater (ML100HPA) — PROCEDURE diagram (page 11)
Fig. 20

Figure 18 - Pilot

Page 12 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual —  TO TURN OFF  GAS TO APPLIANCE
Page 12 · click to enlarge
Page 12

OPERATING YOUR HEATER

THERMOSTAT MODEL ML100TPA

4. Wait five(5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “ B ” in the safety information on the side of heater. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise
Procom Vent-Free Blue Flame Heater (ML100HPA) — THERMOSTAT MODEL ML100TPA diagram (page 12)
Fig. 21

FOR YOUR SAFETY READ BEFORE LIGHTING

Figure 21 - Control Knob In The OFF Position

to the PILOT position. Press in control knob for five(5) seconds. (see Figure 21). Note: You may be running this

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

heater for the first time after hook- ing up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system. If control knob does not pop up

Figure 22 - Pilot

Procom Vent-Free Blue Flame Heater (ML100HPA) —  FOR YOUR SAFETY  READ BEFORE LIGHTING diagram (page 12)
Fig. 22

when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, refer to Troubleshooting, pages 14

WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electric

switch, do not use any phone in your building. Immediately call your gas

Figure 23 - Burner Partterns

supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas

THERMOSTAT CONTROL OPERATION The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may ex- ceed the set temperature. If so,the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level between HI and LO. Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet.This may not always agree with room temperature(depending on housing construction, installation location, room size, open air temperatures,etc.) Frequent use of your heater will let you determine your own comfort levels.

through 16. Also contact a quali- fied service person or gas sup- plier for repairs. Until repairs are m a d e , l i g h t p i l o t w i t h match.To light pilot with match,

supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it , call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immedi- ately call a qualified service techni- cian to inspect the appliance and to replace any part of the control sys- tem and any gas control which has been under water.

see Manual Lighting Procedure. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. If control knob does not

pop up when released, contact a qualified service person or gas supplier for repairs.

TO TURN OFF GAS TO APPLIANCE

LIGHTING INSTRUCTIONS

Shutting Off Heater 1. Turn control knob clockwise

level. The main burner should light. Set control knob to any

to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit ) Turn control knob clockwise

1. STOP! Read the safety information on the side of heater. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise

heat level between HI and LO. (see Figure 23)

to the PILOT position.

to the OFF position.

to desired seating

Page 13 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — CLEANING AND MAINTENANCE
Page 13 · click to enlarge
Page 13

OPERATING HEATER Continued

BURNER FLAME PATTERN Figure 26 shows a correct burner flame pattern. Figure 26 shows an incorrect burner flame pattern.

ODS/PILOT AND BURNER Use a vacuum cleaner, pres-

MANUAL LIGHTING

PROCEDURE

surized air, or a small, soft bristled brush to clean.

1. Remove lower front panel (see Figure 7 page 7). 2. Follow steps through 5 under Lighting Instructions on page12. 3. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.Follow step 8 under Lighting Instuctions on page 12. 5. Replace lower front panel.

CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit every 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSl. Your local computer store, hardware store. or home cen- ter may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, and pilot for dust and dirt. 3. Blow air through the ports/slots and holes in the bumer. Also clean the pilot assembly. A yellow tip on the pilot flame indi- cates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 28). With the unit off , lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

If burner flame pattern is incorect, as shown in Figure 27 turn heater off (see To Turn Off

Gas to Appliance pages 11&12) see Troubleshooting (pages 14

Procom Vent-Free Blue Flame Heater (ML100HPA) — PROCEDURE diagram (page 13)
Fig. 23

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 25. turn heater off (see To Turn Off Gas to Appliance. page 11,12 see Troubleshooting. pages 14 through 16.

Figure 26 - Correct Burner Flame Pattern

Procom Vent-Free Blue Flame Heater (ML100HPA) — INSPECTING BURNER diagram (page 13)
Fig. 24

Figure 27 - Incorrect Burner Flame Pattern

Procom Vent-Free Blue Flame Heater (ML100HPA) — INSPECTING BURNER diagram (page 13)
Fig. 25
Procom Vent-Free Blue Flame Heater (ML100HPA) — INSPECTING BURNER diagram (page 13)
Fig. 26

CLEANING AND MAINTENANCE

Figure 24 - Correct Pilot Flame Pattern

Procom Vent-Free Blue Flame Heater (ML100HPA) — CLEANING AND MAINTENANCE diagram (page 13)
Fig. 27

Figure 28 - Pilot Air Inlet Hole

CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean. Exterior Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

Figure 25 - Incorrect Pilot Flame Pattern

through 16)

Page 14 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — OBSERVED PROBLEM
Page 14 · click to enlarge
Page 14

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed and control knob is pressed in and turned to the PILOT position, there is no spark at ODS/pilot.

1. Ignitor electrode is positioned wrong. 2. Ignitor electrode is broken. 3. Ignitor electrode is not connected to ignitor cable. 4. Ignitor cable is pinched or wet.
1. Replace ignitor.
2. Replace ignitor. 3. Reconnect ignitor cable.
4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry. 5. Replace ignitor cable. 6. Replace piezo ignitor.
5. Broken ignitor cable. 6. Bad piezo ignitor.

When ignitor button is pressed and control knob is press in and turned to the PILOT position, there is a spark at ODS/pilot but no ignition.

1. Gas supply turned off or equipment shutoff valve is closed. 2. Control knob not fully pressed in while pressing ignitor button 3. Air in gas lines when installed.
1. Turn on gas supply or open equipment shutoff valve. 2. Fully press in control knob while pressing ignitor button. 3. Continue holding down control knob. Repeat igniting operation until air is removed. 4. Clean ODS/pilot (see Cleaning and Maintenamce, Page 13) or replace ODS/pilot assembly. 5. Turn control knob to PILOT position. 6. Replace gas regulator. 7. Contact local prapane/LP gas company.
4. ODS/pilot is clogged.
5. Control knob not in PILOT position. 6. Gas regulator setting is not correct. 7. Depleted gas supply.

ODS/pilot lights but flame goes out when control knob is released.

1. Control knob is not fully pressed in. 2. Control knob is not pressed in long enough. 3. Equipment shutoff valve is not fully open. 4. Thermocouple connection loose at control valve.
1. Press in control knob fully.
2. After ODS/pilot lights, keep control knob pressed in 30 seconds. 3. Fully open equipment shutoff valve
4. Hand tighten until snug, then tighten 1/4 turn more.
5. Thermocouple damaged. 6. Control valve damaged.
5. Replace thermocouple. 6. Replace control valve.
Page 15 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — OBSERVED PROBLEM
Page 15 · click to enlarge
Page 15

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner(s)does not light after ODS/pilot is lit.

1. Burner orifice is clogged.
1. Clean burner orifice (see Cleaning and Maintenance Page 13) or replace burner orifice. 2. Replace burner orifice. 3. Contact local propane/LP gas company.
2. Burner orifice diameter is too small. 3. Inlet gas pressure is too low.

Delayed ignition of burner(s).

1. Manifold pressure is too low. 2. Burner orifice is clogged.
1. Contact local propane/LP gas company 2. Clean burner (see Cleaning and Maintenance Page 13) or replace burner orifice.

Burner backfiring during combustion.

1. Burner orifice is clogged or damaged.
1. Clean burner orifice (see Cleaning and Maintenance Page 13) or replace. 2. Replace burner. 3. Replace gas regulator.
2. Burner is damaged. 3. Gas regulator is defective.

Burner plaque(s) does not glow.

1. Plaque damaged. 2. Inlet gas pressure is too low.
1. Replace burner. 2. Contact local propane/LP gas company. 3. Turn control knob until it locks at desired setting.
3. Control knob set between locked positions.

Slight smoke or odor during initial operation.

1. Residues from manufacturing processes.
1. Problem will stop after a few hours of operation.

Heater produces a clicking/ticking noise just after burner is lit or shut off.

1. Metal is expanding while heating or contracting while cooling.
1. This is common with most heaters. If noise is excessive, contact qualified service person.

White powder residue forming within burner box or on adjacent walls or furniture.

1. When heated the vapors from furniture polish, wax, carpet cleaners, etc. turn into white powder residue.
1. Turn heater off when using furniture polish, wax, carpet cleaner, or similar products.
Page 16 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — OBSERVED PROBLEM
Page 16 · click to enlarge
Page 16

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces unwanted odors.

1. Heater is burning vapors from paint, hair spray, glues, etc. (See IMPORTANT statement above). 2. Gas leak. See Warning Statement at top of page. 3. Low fuel supply.
1. Ventilate room. Stop using odor causing products while heater is running. 2. Locate and correct all leaks(see Checking Gas Connections, page 10). 3. Refill supply tank.

Heater shuts off in use (ODS operates).

1. Not enough fresh air is available.
1. Open window and/or door for ventilation. 2. Contact local propane/LP gas company. 3. Clean ODS/pilot (see Cleaning page 13).
2. Low line pressure.
3. ODS/pilot is partially clogged

Gas odor exists even when control knob is in OFF position.

1. Gas leak. See Warning Statement at top of page.
1. Locate and correct all leaks(see Checking Gas Connections, page 10). 2. Replace control valve.
2. Control valve defective.

Gas odor during combustion.

1. Foreign matter between control valve and burner. 2. Gas leak. See Warnin Statement at top of page.
1. Take apart gas tubing and remove foreign matter. 2. Locate and correct all leaks (see Checking Gas Connections, page 10).

Moisture/condensation noticed on windows.

1. Not enough combustion/ventilation air.
1. Refer to Air for Combustion and Ventilation requirements ,page 4.
Page 17 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — 14 " 11 "
Page 17 · click to enlarge
Page 17

SPECIFICATIONS

ML100HPA 5,500/10,000 propane/LP Only

ML100TPA

Btu(available) Gas Type Ignition Pressure Regulator setting Inlet Gas Pressure* (inches of water) Maximum Minimum Dimensions, Inches (HxWxD) Heater Carton Weight (pounds) Heater Shipping

Piezo 10" W.C.

Piezo 10" W.C.

Piezo 10" W.C.

14 " 11 "

14 " 11 "

14 " 11 "

19-1/8 × 14-1/8 × 6-3/8 22 × 16-3/4 × 8-1/8

19-1/8 × 14-1/8 × 6-3/8 22 × 16-3/4 × 8-1/8

119-1/8 × 14-1/8 × 6-3/8 22 × 16-3/4 × 8-1/8

TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact PRO-COM through phone number 1- 877-886-5989.The information is listed on the front of manual.

Procom Vent-Free Blue Flame Heater (ML100HPA) — 14 " 11 " diagram (page 17)
Fig. 28

REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call the num- ber on the front of this manual. When contacting your dealer or PRO-COM, have ready: your name your address model and serial numbers of your heater how heater was malfunctioning type of gas used (propane/LP or natural gas) purchase date warranty card Usually, we will ask you to return the defective part to the factory.

SERVICE HINTS When Gas Pressure Is Too Low Pilot will not stay lit Burner will have delayed ignition Heater will not produce specified heat Propane/LP gas supply may be low

EQUIPMENT SHUTOFF VALVE For all models. Equipment shutoff valve with 1/8" NPT tap.

Procom Vent-Free Blue Flame Heater (ML100HPA) — 14 " 11 " diagram (page 17)
Fig. 29

When Gas Quality Is Bad Pilot will not stay lit Burner will produce flames and soot Heater will backfire when lit

You may feel your gas pressure is too low or the gas quality is poor . If so, contact your local propane/LP gas supplier.

PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), contact PRO- COM through the phone number1- 877-886-5989.

ACCESSORIES Purchase these heater accesso- ries from your local dealer. If they can not supply these accessories, contact PRO-COM for information. You can also write to the address listed on the front of this manual.

FLOOR MOUNTING STAND Models ML060HPA,ML100HPA, ML100TPA For locating heater on the floor away from a wall. Complete installation instructions provided with floor mounting stand.

6,000 propane/LP Only · 10,000 propane/LP Only

Page 18 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — ILLUSTRATED PARTS
Page 18 · click to enlarge
Page 18

ILLUSTRATED PARTS

BREAKDOWN

Procom Vent-Free Blue Flame Heater (ML100HPA) — ILLUSTRATED PARTS diagram (page 18)
Fig. 30
Page 19 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — PARTS AVAILABLE NOT SHOWN
Page 19 · click to enlarge
Page 19

PARTS LIST

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual.

KEY NO.

PART

NUMBER

DESCRIPTION

QTY

1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

MB10008 MB09003 ML006-02 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026-03 ML069-02 NV2020-12 ML073-01 ML029-01 MB40051 MB40052 MB40053 ML090-05 MB16002 NRV81FI-10 Ml129-02 ML079-01 ML119-01 MB29003 ML060-02 ML083-03

Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screws Control Valve Ignitor Line Control Valve Fixed Nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Line Assembly Injector Control Knob Assembly Pressure Regulator Regulator Mounting Bracket Self Locking Screws Pressure Tap Grill Guard Mounting Bracket lgnitor Assembly

10 1 4 1

PARTS AVAILABLE NOT SHOWN

MB28001 ML070-32

Assembly Hardware CSA/AGA Label

Page 20 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — ILLUSTRATED PARTS
Page 20 · click to enlarge
Page 20

ILLUSTRATED PARTS

BREAKDOWN

Procom Vent-Free Blue Flame Heater (ML100HPA) — ILLUSTRATED PARTS diagram (page 20)
Fig. 31
Page 21 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — MB28001 ML070-02
Page 21 · click to enlarge
Page 21

PARTS LIST

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual.

KEY NO.

PART

NUMBER

DESCRIPTION

QTY

1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

MB10008 MB09003 ML006-01 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026-02 ML069-02 NV2020-13 ML073-01 ML029-01 MB40033 MB40034 MB40035 MB40036 ML090-04 MB16002 NRV81FI-10 ML129-02 ML079-01 ML119-01 MB29003 ML060-02 ML083-03

Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screws Control Valve Ignitor Line Control Valve Fixed Nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Line Assembly A Burner Gas Line Assembly B Injector Control Knob Assembly Pressure Regulator Regulator Mounting Bracket Self Locking Screws Pressure Tap Grill Guard Mounting Bracket lgnitor Assembly

10 1 2 1 1 1 4 1

PARTS AVAILABLE NOT SHOWN

Assembly Hardware CSA/AGA Label

MB28001 ML070-02

Page 22 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — ILLUSTRATED PARTS
Page 22 · click to enlarge
Page 22

ILLUSTRATED PARTS

BREAKDOWN

ML100TPA

Procom Vent-Free Blue Flame Heater (ML100HPA) — ILLUSTRATED PARTS diagram (page 22)
Fig. 32
Page 23 of the Procom Vent-Free Blue Flame Heater (ML100HPA) user manual — MB28001 ML070-30
Page 23 · click to enlarge
Page 23

PART LIST

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual.

ML100TPA

KEY NO.

PART NUMBER MB10007 MB09003 ML006-01 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026-02 ML069-02 845-4.8x60Z SIT544-000 ML111-02 ML056-03 MB40037 MB40039 MB40038 MB40040 ML090-04 MB40041 NRV81FI-10 ML129-02 ML079-01 MB29003 ML060-02 ML083-03

DESCRIPTION

QTY

1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screws Screws Thermostat Valve Assembly Thermostat Valve Base/Bracket “T” Joint Main Inlet Tube Assembly ODS Gas Line Assembly Main Outlet Tube Assembly Burner Gas Line Assembly A Injector Burner Gas Line Assembly B Pressure Regulator Regulator Mounting Bracket Self Locking Screws Grill Guard Mounting Bracket lgnitor Assembly

10 1 2 1 1 1 4 1 1 1

PARTS AVAILABLE NOT SHOWN

Assembly Hardware CSA/AGA Label

MB28001 ML070-30

Ask about the Procom Vent-Free Blue Flame Heater (ML100HPA)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Procom Vent-Free Blue Flame Heater (ML100HPA)

Be the first to ask — other owners or our team will answer.

Original document

Procom Vent-Free Blue Flame Heater (ML100HPA) manual PDF

23 pages·1.4 MB·Electric Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…