copy of 527 CMR 30 upon sale of the unit.
In the state of Massachusetts, unvented propane or nature gas-fired space heat- ers shall be prohibited in bedrooms and bathrooms.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outside. 3. If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. 4. This heater shall not be installed in a bathroom or bedroom. 5. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensor (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Fresh Air for Combustion and Ventilation pages 4 and 5. 6. Keep all air openings in front and at the bottom of heater clear and free of debris. This will insure enough air for proper combustion. 7. If heater shuts off. Do not relight until you provide fresh outside air. If heater keeps shutting off, have it serviced. 8. Do not operate heater where flammable liquids or vapors are used or stored under dusty conditions
Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 11. Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. 12. Operating heater above elevations of 4,500 feet could cause pilot outage. 13. To prevent performance, problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.
Due to high temperatures, heater s h o u l d b e k e p t o u t o f traffic and away from furniture and draperies.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more af- fected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Propane/LP Gas: Propane/LP gas is odorless. An odor-making agent is added to Propane/LP gas. The odor helps you detect a Propane/LP gas leak. However, the odor added to Propane/LP gas can fade. Propane/ LP gas may be present even though no odor exists. Make certain you read and under- stand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shuting down. Allow surface to cool before touching.
Carefully supervise young children when they are in the same room with heater.
Make sure grill guard is in place before running the heater.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
State of Massachusetts: The installation must be made by a li- censed plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natu- ral gas-fired supplemental room heat- ers shall provide to each purchaser a


Figure1-Vent-Free Propane/LP Gas Heater
SAFETY DEVICE A standard requirement for all vent-free room heaters. This heater has a pilot with an Oxygen Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas code ANSZ223.1, also known as NFPA 54*. *Available from : American National Standards Institute, Inc.
1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.
THERMOSTATIC HEAT CONTROL ON THERMOSTAT MODELS These heaters have a control valve with a thermostat sensing bulb. This results in the greatest heater comfort and may result in lower gas bills.
UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
The following steps will help insure that water vapor does not become a problem. 1. Be sure the heater is sized properly for the application, including ample combustion air and circulation air. 2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor con- tent of the air. 3. Do not use an unvented room heater as the pri- mary heat source.
Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’s (3KW’s) of gas input per hour. Unvented room heaters are recommended as supple- mental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor en- hances the low humidity atmosphere experienced during cold weather.
Batterymarch Park · Quincy, MA 02269

Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one per m (6×10-11
Confined and Unconfined Space The National Fuel Gas Code ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with t h e s p a c e i n w h i c h t h e appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space. This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. * Adjoining rooms are communicat- ing only if there are doorless pas- sageways or ventilation grills between them.
kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air from Outdoors, page 6. If your home does not meet all of the three criteria above see Determining Fresh-Air Flow for Heater Location, page 5.
The following are excerpts from National Fuel Gas Code. NFPA 54/ ANS Z223.1, Section 5.3. Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if you have a Confined or Unconfined Space* Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length×width×height). Length×Width×Height= cu.ft. (volume of space) Example: Space size20ft. (length)×16ft. ( width)×8ft. (ceiling height)=2560cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
(volume of space)÷50 cu. ft.=(Maximum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space)÷50 cu.ft.=51.2 or 51.200(maximum Btu/Hr the space can support)

3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas Fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr *Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used. Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr(maximum the space can support) 60,000 Btu/Hr(actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From inside Building, page 5. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6 . C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
Example: Gas water heater 40,000 Btu/Hr Vent free heater + 20,000 Btu/Hr Total = 60,000 Btu/Hr
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1. Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts

Figure 2 -Ventilation Air from Inside Building


Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3. Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.
Figure 3 -Ventilation Air from Outdoors
*A CSA/AGA design-certified equip- ment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design certified equipment shutoff valve from your dealer. See Accessories, page 17. LOCATING HEATER This heater is designed to be mounted on a wall. You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 17. For convenience and efficiency, install heater where there is easy access for operation, inspection, and service in coldest part of room An optional fan kit is available from your dealer. See Accessories, page 17. If planning to use fan, locate heater near an electrical outlet.
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to h e a t e r . I n s t a l l i n g h e a t e r next to vinyl or cloth wall c o v e r i n g s o r o p e r a t i n g heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist may discolor walls.
CHECK GAS TYPE Use only Propane/LP gas. If your gas supply is not Propane/LP, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION NEEDS Before installing heater, make sure you have the items listed below. piping (check local codes) sealant (resistant to Propane/LP gas) equipment shutoff valve* ground joint union test gauge connection* sediment trap tee joint pipe wrench

FASTENING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater (see Figure 6). It has been taped there for shipping. Remove mounting bracket from back panel.
Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.
Figure 6 -Mounting Bracket Location
Removing Lower Front Panel Of Heater 1. Remove two screws near bottom corners of lower front panel. 2. Pull bottom of lower front panel forward, then down (see Figure 7).
Figure 4 -Mounting Clearances As View From Front Of Heater


INSTALLING THERMOSTAT SENSING BULB For T-Stat Models Only 1. Pull out the sensing bulb from the two clips located in the shippng position according to the direction as shown by the arrow. There is no need to take out the two bulb clips. 2. Take out the bulb clip from the hardware package and insert it into the square hole and then insert the sensing bulb into the bulb clip (see Figure 5).
Figure 7 - Removing Lower Front Panel Of Heater
Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from center. Attach mounting bracket to wall only in one of two ways: 1. Attaching to wall stud 2. Attaching to wall anchor


Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.
Figure 5 - Moving Thermostat Sensing Bulb
Figure 8 - Mounting Bracket Clearances
Model ML300HBA ML300TBA · Model ML200HBA ML200TBA

Attaching Mounting Bracket to Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64" drill bit. 2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall. 3. Insert mounting screws through bracket and into wall studs. 4. Tighten screws until mounting bracket is firmly fastened to wall studs. Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2. Fold wall anchor as shown in Figure 9 below.


Figure 12 - Installing Bottom Mounting Screws
Figure 10 - Popping Open Anchor Wing For Thin Walls
install wall anchors. Follow steps 1 through 4 under Attaching To Wall Anchor Method. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacers between’ bottom mounting holes and wall anchor or drilled holes. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled holes. 8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note: Do not replace lower front panel at this time. Replace lower front panel after making gas connections and checking for leaks(see page 10) .
Bracket 1. Locate two horizontal slots on back panel of heater (see Figure 11). 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.


Figure 9 - Folding Anchor
Figure 11 - Mounting Heater Onto Mounting Bracket
Installing Bottom Mounting Screws 1. Locate two bottom mounting holes. These holes are near bottom on back panel of heater(see Figure 12).


From External LP Gas Regulator
The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.
Figure 14 -Gas Connection
*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessories, page 17.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Typical Inlet Pipe Diameters All models up to 20,000 BTU’s use 3/8’’ or greater pipe; All models 25,000 BTU’s and higher, use 1/2” or greater pipe. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14).
Install sediment trap in supply line as shown in Figure 14. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly. IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.
Figure 13 - External Regulator with Vent Pointing Down

OPERATING YOUR HEATER
CHECKING GAS CONNECTIONS
THERMOSTAT MODELS
FOR YOUR SAFETY READ BEFORE LIGHTING
1. Open equipment shutoff valve (see Figure 15). 2. Open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 16 ). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 10 and 11 for thermostat models or page 12 for non-thermostat models).Check the rest of the internal joints for leaks. 7. Turn off heater (see To Turn Off Gas To Appliance, page 11 for thermostat models or page 12 for non-thermostat models). 8. Replace lower front panel.
A. When lighting the pilot, follow , these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor .
Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 K Pa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check
WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Figure 15 -Equipment Shutoff Valve

reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 K Pa) 1. Close equipment shutoff valve (see Figure 15). 2. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 3. Check all joints from gas meter to equipment shutoff valve (see Figure 16).Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Figure 16 -Checking Gas Joints

This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room tem- perature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Selecting the HI setting will cause the burner to remain fully on without modulating down in most cases.
to desired heating Level. The main burner should light. Set control knob to any heat level between HI and LO.
NOTE: the thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not al- ways agree with room temperature (depending on housing construction. installation location, room size, open air temperatures, etc.), frequent use of your heater will let you determine y o u r o w n c o m f o r t l e v e l s .

GAS TO APPLIANCE
Shutting Off Heater 1. Turn control knob clockwise
to “PILOT/IGN” and depress for five(5) seconds NOTE: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob should be depressed for about thirty (30) seconds. This will allow air to bleed from the gas system.
Figure 17 - Control Knob In The OFF Position
to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. SHUTTING OFF BURNER ONLY (PILOT STAYS LIT) Turn control knob clockwise

to the PILOT/IGN position.
PROCEDURE 1. Remove lower front panel (see Figure 7 page 7). 2. Follow steps 1 through 5 under Lighting Instructions. 3. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions. 5. Replace lower front panel.
Figure 18 - Pilot
The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner.

LIGHTING INSTRUCTIONS
6. With control knob pressed in, push down and release the ignitor button. This will light pilot. if needed, keep pressing ignitor button until pilot lights. 7. Keep control knob depressed for ten(10) seconds after lighting pilot. If pilot goes out, repeat steps 5,6 and 7. 8. To select the desired heating level, partially press down the control knob slightly and rotate counterclockwise . Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position. Do not operate between locked positions.
FOR YOUR SAFETY READ BEFORE LIGHTING
to the OFF position (see Figure 19). 4. Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas.STOP! Follow "B" in the safety information on the side of heater. If you can’t smell gas, go
A. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
to the next step. 5. Push in and turn control knob counterclockwise
to PILOT position. Press in control knob for five(5) seconds. Note: You may be running
Do not try to light any appliance. Do not touch any electric
this heater for the first time after hooking up to gas supply. If so, you may need to press in control knob for 30 seconds. This will allow air to bleed from the gas system.
Shutting Off Heater 1. Turn control knob clockwise
to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed.
switch; do not use any phone in your building. Immediately call your gas
supplier from a neighbor’s phone. Follow the gas supplier’s instructions. if you cannot reach your gas
Shutting Off Burner Only (pilot stays lit ) Slightly press in control, turn control knob clockwise

to the PILOT position.
supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it , call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Figure 19 - Control Knob in The OFF Position
Lighting Instructions. 5. Replace lower front panel.
Figure 20 - Pilot

Check pilot flame pattern and burner flame pattern often.
We recommend that you clean the unit every 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using com- pressed air no greater than 30 PSl. Your local computer store, hard- ware store. or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don’t follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot for dust and dirt. 3. Blow air through the ports/slots and holes in the burner. Also, clean the pilot assembly. A yel- low tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pi- lot flame comes out of the pilot as- sembly (see Figure 25). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
PILOT FLAME PATTERN Figure 21 shows a correct pilot flame pattern. Figure 22 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 22. turn heater off (see To Turn

Off Gas To Appliance. page 12 for non-thermostat models or page 11 for thermostat models.) see Troubleshooting. pages 14 through 16.
Figure 23 - Correct Burner Flame Pattern


Figure 21 - Correct Pilot Flame Pattern
Figure 24 - Incorrect Burner Flame Pattern


Figure 22 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN Figure 23 shows a correct burner flame pattern. Figure 24 shows an incorrect burner flame pattern. If pilot flame pattern is incorrect, as shown in Figure 24. turn heater off (see To Turn Off
Figure 25 - Pilot Inlet Air Hole
CLEANING HEATER CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean. Exterior Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.
Gas To Appliance. page 12 for non- thermostat models or page 11 for thermostat models) see Troubleshooting. (pages 14 through 16)
CLEANING ODS/PILOT AND BURNER Use a vacuum cleaner,
pressurized air or a small, soft bristled brush to clean.

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed in, there is no spark at ODS/pilot.
When ignitor button is pressed in, there is a spark at ODS/pilot but no ignition.
replace ODS/pilot assembly 5. Replace gas regulator. 6. Turn control knob to pilot position. 7. Contact local propane/LP gas campany.
ODS/pilot lights but flame goes out when control knob is released.

Continued
POSSIBLE CAUSE
REMEDY
Burner(s)does not light after ODS/pilot is lit.
Delayed ignition of burner(s).
Burner backfiring during combustion.
Yellow flame during burner combustion.
Slight smoke or odor during initial operation.
Heater produces a whistling noise when burner is lit.
Heater produces a clicking/ticking noise just after burner is lit or shut off.
White powder residue forming within burner box or on adjacent walls or furniture.

Continued
POSSIBLE CAUSE
REMEDY
Heater produces unwanted odors.
Heater shuts off in use (ODS operates).
Gas odor even when control knob is in OFF position.
Gas odor during combustion.
Heater produces a clicking/ticking noise just after burner is lit or shut off.
Moisture/condensation noticed on windows.

ML200TBA
ML300HBA 15,000/28,000 Propane/LP Only
Btu(available) Gas Type Ignition Pressure Regulator setting Inlet Gas Pressure *(inches of water) Maximum Minimum Dimensions, Inches (HxWxD) Heater Carton Weight (pounds) Heater Shipping
Piezo 8" W.C.
8" W.C.
8" W.C.
8" W.C.
23 1/2×26 5/8×8 26 1/2×28 1/2×9 1/4
26 1/2×21 3/4×9 1/4
26 1/2×28 1/2×9 1/4
26 1/2×21 3/4×9 1/4
REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call the number on the front of this manual . When contacting your dealer or PRO-COM, have ready: your name your address model and serial numbers of your heater how heater was malfunctioning type of gas used (propane/LP or natural gas) purchase date warranty card Usually, we will ask you to return the defective part to the factory. PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), contact PRO-COM’S phone number (877) 886-5989. TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact PRO-COM’S phone number (877) 886-5989.
ACCESSORIES Purchase these heater accesso- ries from your local dealer. If they can not supply these accessories, contact PRO-COM for information. You can also write to the address listed on the front of this manual.
Optional FAN Kit The optional fan kit, part PF06-YJLF-B fits all models noted in this manual. The fan has 3 settings ON/OFF/Auto. The thermostatically controlled PF06-
YJLF-B improves heater efficiency and includes installation and operating instructions.


EQUIPMENT SHUTOFF VALVE For all models. Equipment shutoff valve with 1/8" NPT tap.

For locating heater on the floor, away from a wall. Complete installa- tion instructions provided with floor mounting stand.

PARTS BREAKDOWN
THERMOSTAT MODELS ML200TBA ML300TBA


This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 17 of this manual.
MODELS
ML200TBA, ML300TBA
KEY NO.
ML200TBA PART NO.
ML300TBA PART NO.
QTY.
DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Glass Upper Glass Retainer Lower Glass Retainer Self Tapping Screw Thermostat Valve Assembly Screws Thermostat Valve Base Ignitor Assembly Ignitor Line Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembly ODS Line Assembly Burner Inlet Tube Assembly Burner Burner Connector Injector Left Burner Support Bracket Right Burner Support Bracket ODS Thermocouple Ignitor Electrode ODS Upper Deflector NUT Grill Guard Middle Panel Mounting Bracket
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 24-1 24-2 25 26 27 28 29
MB10005 MB09002 MB11004 ML086-02 ML087-02 ML088-02 ML069-02 SIT545-130 845-4.8x60Z ML111-01 ML083-03 ML073-01 NRV81FI-8 96-4Z ML079-01 MB40006 MB40022 MB40023 NBB20-000B1 ML101-01 ML091-12 ML103-01 ML104-01 ND1908x800x9 ND0803-8 ND0807-B2 ML105-01 6170-5Z MB29002 ML084-02 ML060-01
MB10002 MB09001 MB11002 ML086-01 ML087-01 ML088-01 ML069-02 SIT545-175 845-4.8x60Z ML111-01 ML083-03 ML073-01 NRV81FI-8 96-4Z ML079-01 MB40006 MB40022 MB40023 NBB30-000B1 ML101-01 ML091-07 ML103-01 ML104-01 ND1908x800x9 ND0803-8 ND0807-B2 ML105-01 6170-5Z MB29001 ML084-01 ML060-01
16 1 2 1 2 2 1 2 1 1 1
MB28001 ML070-22 ML071-02 ML072-01 ML065-01
MB28001 ML070-24 ML071-02 ML072-01 ML065-01
Hardware Kit CSA/AGA Label Gas Instruction Decal Inside Warning Label Thermostat Sensing Bulb Clip
1 2

BREAKDOWN
NON-THERMOSTAT MODELS ML200HBA ML300HBA

ODS/Pllot Assembly

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 17 of this manual.
ML300HBA
KEY NO.
ML200HBA PART NO.
ML300HBA PART NO.
QTY
MB10005 MB09002 MB11004 ML086-02 ML087-02 ML084-02 ML088-02 ML069-02 NV2020-14 ML073-01 MB16002 ML029-01 NRV81FI-8 96-4Z ML079-01 MB40016 MB40018 MB40019 MB40020 MB40021 ML096-01 MB40017 NBB20-000B1 ML101-01 ML091-12 ML103-01 ML104-01 ND1908x800x9 ND0803-8 ND0807-B2 ML105-01 6170-5Z MB29002 ML083-03 ML060-01
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28-1 28-2 29 30 31 32 33
MB10003 MB09001 MB11002 ML086-01 ML087-01 ML084-01 ML088-01 ML069-02 NV2020-14 ML073-01 MB16002 ML029-01 NRV81FI-8 96-4Z ML079-01 MB40016 MB40018 MB40019 MB40020 MB40021 ML096-01 MB40017 NBB30-000B1 ML101-01 ML091-07 ML103-01 ML104-01 ND1908x800x9 ND0803-8 ND0807-B2 ML105-01 6170-5Z MB29001 ML083-03 ML060-01
Cabinet Assembly Lower Front Panel Assembly Reflector Unit Glass Upper Glass Retainer Middle Panel Lower Glass Retainer Self Tapping Screw Control Valve Ignitor Line Control Knob Assembly Control Valve Fixed Nut Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembly ODS Line Assembly Lower Gas Outline Tube Assembly Medium Gas Outline Tube Assembly High Gas Outline Tube Assembly 4-Way Connector Burner Inlet Tube Assembly Burner Burner Connector Injector Left Burner Support Bracket Right Burner Support Bracket ODS/pilot Assembly Thermocouple Ignitor Electrode ODS Upper Deflector NUT Grill Guard lgnitor Assembly Mounting Bracket
16 1 2 2 1 2 2 1 1
MB28001 ML070-16 ML071-02 ML072-01
MB28001 ML070-18 ML071-02 ML072-01
Hardware Kit CSA/AGA Label Gas Instruction Decal Inside Warning Label
1