CAUTION - FOR YOUR SAFETY

-- Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.

-- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air For Combustion and Ventilation section on page 9 of this manual.

INSTALLER: DO NOT DISCARD THIS MANUAL – LEAVE FOR HOMEOWNER’S FUTURE REFERENCE.

This appliance may be installed in an aftermarket, permanently located manufactured (mobile) home, where not prohibited by local codes. This appliance is for use with the type of gas indicated on the rating plate only. This appliance is not convertible for use with other gases.

Questions about installation, operation, or troubleshooting? Before returning to your retailer, call customer service department toll-free at (877)886-5989.

PC-MD100TBE-0902

Page 2 of the Procom MD100TBA user manual — Vent-Free Gas Wall Heater
Page 2 · click to enlarge
Page 2
Page 2 of the Procom MD100TBA user manual — Vent-Free Gas Wall Heater
Page 3 of the Procom MD100TBA user manual — PRODUCT SPECIFICATIONS
Page 3 · click to enlarge
Page 3

PRODUCT SPECIFICATIONS

MODELMD100TBAMD200TBAMD300TBA BTU (available)10,00020,00030,000 Gas TypeUsing Natural GasUsing Natural GasUsing Natural Gas Pressure Regulator Setting4 in. W.C.4 in. W.C.4 in. W.C. Inlet Gas Pressure* (inches of water) * For purposes of input adjustment. Maximum10.5 in.10.5 in.10.5 in. Minimum *5 in.5 in.5 in. Gas TypeUsing Propane GasUsing Propane GasUsing Propane Gas Pressure Regulator Setting9 in. W.C.9 in. W.C.9 in. W.C. Inlet Gas Pressure* (inches of water) * For purposes of input adjustment. Maximum14 in.14 in.14 in. Minimum *11 in.11 in.11 in. IgnitionElectric PiezoElectric PiezoElectric Piezo Dimensions, Inches (HxWxD) Heater19 1/8 × 14 1/8 × 6 3/823 1/2 × 19 1/4 × 823 1/2 x 26 5/8 x 8 Carton22 ×16 3/4 × 8 1/826 1/2 × 21 3/4 × 9 1/426 1/2 x 28 1/2 x 9 1/4 Weight (Pounds) Heater14.622.228.1 Shipping17.626..233.1 MODELMD100HBAMD200HBAMD300HBA BTU (available)10,00020,00030,000 Gas TypeUsing Natural GasUsing Natural GasUsing Natural Gas Pressure Regulator Setting4 in. W.C.4 in. W.C.4 in. W.C. Inlet Gas Pressure* (inches of water) * For purposes of input adjustment. Maximum10.5 in.10.5 in.10.5 in. Minimum *5 in.5 in.5 in. Gas TypeUsing Propane GasUsing Propane GasUsing Propane Gas Pressure Regulator Setting9 in. W.C.9 in. W.C.9 in. W.C. Inlet Gas Pressure* (inches of water) * For purposes of input adjustment. Maximum14 in.14 in.14 in. Minimum *11 in.11 in.11 in. IgnitionElectric PiezoElectric PiezoElectric Piezo Dimensions, Inches (HxWxD) Heater19 1/8 × 14 1/8 × 6 3/823 1/2 × 19 1/4 × 823 1/2 x 26 5/8 x 8 Carton22 ×16 3/4 × 8 1/826 1/2 × 21 3/4 × 9 1/426 1/2 x 28 1/2 x 9 1/4 Weight (Pounds) Heater14.121.227.1 Shipping17.625.232.1
Page 4 of the Procom MD100TBA user manual — PRODUCT SPECIFICATIONS
Page 4 · click to enlarge
Page 4
Procom MD100TBA — PRODUCT SPECIFICATIONS diagram (page 4)
Fig. 3
MODELMD200TBA-BBMD300TBA-BB BTU (available)20,00030,000 Gas TypeUsing Natural GasUsing Natural Gas Pressure Regulator Setting4 in. W.C.4 in. W.C. Inlet Gas Pressure* (inches of water) * For purposes of input adjustment. Maximum10.5 in.10.5 in. Minimum *5 in.5 in. Gas TypeUsing Propane GasUsing Propane Gas Pressure Regulator Setting9 in. W.C.9 in. W.C. Inlet Gas Pressure* (inches of water) * For purposes of input adjustment. Maximum14 in.14 in. Minimum *11 in.11 in. IgnitionElectric PiezoElectric Piezo Dimensions, Inches (HxWxD) Heater23 1/2 × 19 1/4 × 823 1/2 x 26 5/8 x 8 Carton26 1/2 × 21 3/4 × 9 1/426 1/2 x 28 1/2 x 9 1/4 Weight (Pounds) Heater25.131 Shipping29.136
MODELMD200HBA-BBMD300HBA-BB BTU (available)20,00030,000 Gas TypeUsing Natural GasUsing Natural Gas Pressure Regulator Setting4 in. W.C.4 in. W.C. Inlet Gas Pressure* (inches of water) * For purposes of input adjustment. Maximum10.5 in.10.5 in. Minimum *5 in.5 in. Gas TypeUsing Propane GasUsing Propane Gas Pressure Regulator Setting9 in. W.C.9 in. W.C. Inlet Gas Pressure* (inches of water) * For purposes of input adjustment. Maximum14 in.14 in. Minimum *11 in.11 in. IgnitionElectric PiezoElectric Piezo Dimensions, Inches (HxWxD) Heater23 1/2 × 19 1/4 × 823 1/2 x 26 5/8 x 8 Carton26 1/2 × 21 3/4 × 9 1/426 1/2 x 28 1/2 x 9 1/4 Weight (Pounds) Heater24.130 Shipping28.135
Page 5 of the Procom MD100TBA user manual — important SAFETY INFORMATION
Page 5 · click to enlarge
Page 5

IMPORTANT SAFETY INFORMATION

important SAFETY INFORMATION

Only a qualified installer, service agent, or local gas supplier may install and service this product.

CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning resemble the flu with headache, dizziness and/or nausea. If you have these signs, heater may not be working properly. Get fresh air at once! Have heater serviced. Some people - pregnant women, persons with heart or lung disease, anemia, those under the influence of alcohol, those at high altitude - are more affected by carbon monoxide than others.

Natural and Propane/LP Gas: Natural and Propane/LP gas are odorless. An odor-producing agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

1. This appliance is for use with only the type of gas indicated on the rating plate. This appliance is not

convertible for use with other gases.

2. Do not place Propane/LP supply tank(s) inside any structure. Propane/LP supply tank(s) must be Placed

outdoors.

3. This heater shall not be installed in a bedroom or bathroom, or the place which the strong wind would shut down

the appliance.

4. This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS)

safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for

Combustion and Ventilation, pages 9 through 11. If heater keeps shutting off, see Troubleshooting, pages 23

through 25.

5. Keep all air openings in front and bottom of heater clear and free of debris. This will ensure enough air for

proper combustion.

Page 6 of the Procom MD100TBA user manual — IMPORTANT SAFETY INFORMATION
Page 6 · click to enlarge
Page 6
6. If heater shuts off, do not relight until you have provided fresh, outside air. If heater keeps shutting off, have it

serviced.

7. Do not run heater: Where flammable liquids or vapors are used or stored. Under dusty conditions.
8. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from

these products may create a white powder residue within burner box or on adjacent walls or furniture.

9. Always run heater with control knob at PILOT/IGN, LOW or HIGH locked positions. Never set control knob be

tween locked positions. Poor combustion and higher levels of carbon monoxide may result.

10. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect

the room heater and to replace any part of the control system and any gas control which has been under water.

11.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair

heater.

12. Operating heater above elevations of 4,500 feet could cause pilot outage.
13. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping, gas utilization equipment or accessories, and repair and equipment servicing.The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for:

a) Installing, testing, or replacing gas piping or

b) Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirement of the authority having jurisdiction.

• •

Page 7 of the Procom MD100TBA user manual — LOCAL CODES
Page 7 · click to enlarge
Page 7

PRODUCT FEATURES

SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM This heater is equipped with an electronic piezo control system. This system requires AAA batteries (provided).

2 GAS OPTIONS CAPABLE Your heater is equipped to operate on either Propane or Natural gas. The heater is shipped from the factory ready for connecting to Propane. The heater can easily be changed to Natural gas by having your qualified installer follow the instructions on page 15 and the markings on the heater.

THERMOSTATIC CONTROL ON THERMOSTAT MODEL These heaters have a control valve with a thermostat sensing bulb. This results in the greatest heater comfort and may result in lower gas bills.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

In the State of Massachusetts, unvented propane or natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.

In the State of Massachusetts the gas cock must be a T-handle type. The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/ NFPA 54.

*Available from:

American National Standards Institute, lnc. 1430 Broadway New York, NY 10018

National Fire Protection Association, lnc. 1 Batterymarch Park Quincy, MA 02269-9101

Page 8 of the Procom MD100TBA user manual — WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Page 8 · click to enlarge
Page 8

preparing for installation

Before beginning assembly or operation of the product, make sure all parts are present. Compare parts with package contents list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for replacement parts. Before installing heater, make sure you have the items listed below:

piping (check local codes) sealant (resistant to natural gas and propane/LP gas) equipment shutoff valve* test gauge connection* sediment trap tee joint pipe wrench flexible gas hose (check local codes)

Procom MD100TBA — preparing for installation diagram (page 8)
Fig. 4 · preparing for installation

* A CSA design-certified equipment shutoff valve with 1/8-inch NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design- certified equipment shutoff valve from your dealer.

UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipping 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

Figure 1 - Vent-Free Gas Heater

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30 mL) of water for every 1,000 BTUs (.3 KWs) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applica- tions, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather. The following steps will help ensure that water vapor does not become a problem.

1. Be sure the heater is sized properly for the application, including ample combustion air and circulation air. 2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air. 3. Do not use an unvented room heater as the primary heat source.
Page 9 of the Procom MD100TBA user manual — Confined and Unconfined Space
Page 9 · click to enlarge
Page 9

AIR FOR COMBUSTION AND VENTILATION

Providing Adequate Ventilation This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54, the INTERNATIONAL FUEL GAS CODE, or applicable local codes. The following are excerpts from National Fuel Gas Code, ANSI Z223.1/ NFPA 54. Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 9 through 11 will help you classify your space and provide adequate ventilation.

Confined and Unconfined Space

The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cu. ft. per 1,000 BTU/hr (4.8 m^3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 BTU/hr (4.8 m^3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms connecting directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

* Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them.

Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where:

Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of

one perm (6×10-11kg per pa-sec-m2) or less with openings gasketed or sealed and

Weather stripping has been added on openable windows and on doors and

Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates

and floors, between wall ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide additional fresh air. See “Ventilation Air From

Outdoors”. If your home does not meet all of the three criteria above, proceed to “Determining Fresh-Air Flow For

Heater Location”.

a) · b) · c)

Page 10 of the Procom MD100TBA user manual — DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Page 10 · click to enlarge
Page 10

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1. Determine the volume of the space Length × Width × Height = cu. ft. (volume of space)

Example: Space size 20 ft. (length) × 16 ft. (width)×8 ft. (ceiling height) =2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to

the total volume of the space.

2. Divide the space volume by 50 cubic feet to determine the maximum BTU/hr the space can support.

(volume of space) ÷ 50 cu. ft. =(Maximum BTU/hr the space can support)

3. Add the BTU/hr of all fuel burning appliances in the space.

BTU/hr

ExampleGas water heater 30,000 BTU/hr Vent-free heater + 26,000 BTU/hr Total = 56,000 BTU/hr

Other gas appliances* +

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the

outdoors.

4. Compare the maximum BTU/hr the space can support with the actual amount of

BTU/hr (maximum the space can support)

BTU/hr (actual amount of BTU/hr used)

Example51,200 BTU/hr (maximum the space can support)

56,000 BTU/hr (actual amount of BTU/hr used)

The space in the above example is a confined space because the actual BTU/hr used is more than the maximum BTU/ hr the space can support.

You must provide additional fresh air. Your options are as follows:

Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space,

remove door to adjoining room or add ventilation grills between rooms. See “ Ventilation Air From Inside Building ” on next page.

Vent room directly to the outdoors. See “ Ventilation Air From Outdoors ” on next page.

c) Install a lower BTU/hr heater if lower BTU/hr size makes room unconfined. If the actual BTU/hr used is less than the maximum BTU/hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Show 9 more labels / short text on this page
Vent-free heater · Gas water heater* · Gas furnace · Vented gas heater · Gas heater logs · Total = · BTU/hr used · a) · b)
Page 11 of the Procom MD100TBA user manual — DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Page 11 · click to enlarge
Page 11
Procom MD100TBA — DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION diagram (page 11)
Fig. 5

Ventilation Air From lnside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12 inches of the ceiling and one within 12 inches of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove the door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code. ANSI Z223.1/ NFPA 54, Air for Combustion and Ventilation for required size of entilation grills or ducts.

Figure 2 - Ventilation Air from Inside Building

Procom MD100TBA — DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION diagram (page 11)
Fig. 6

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12 inches of the ceiling and one within 12 inches of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 3 - Ventilation Air from Outdoors

Page 12 of the Procom MD100TBA user manual — INSTALLATION
Page 12 · click to enlarge
Page 12

INSTALLATION

system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

Heater pilot and burner must be at least 18 inches above the floor. Place heater where moving vehicle will not hit it.

in a bedroom or bathroom in a recreational vehicle where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater in high traffic areas in windy or drafty areas

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form too much moisture. See Air for Combustion and Ventilation, pages 9 through 11. Check Gas Type Be sure your gas supply is right for your heater. Otherwise, call dealer where you bought the heater for proper type heater.

Procom MD100TBA — INSTALLATION diagram (page 12)
Fig. 7

Clearances To Combustibles Carefully follow the instructions below. This heater is a freestanding unit designed to be mounted on a wall or set directly on the floor.

LOCATING HEATER This heater is designed to be mounted on a wall. For convenience and efficiency, install heater: 1) where there is easy access for operation, inspection, and service. 2) In the coldest part of room.

Figure 4 - Mouting clearances as viewed from

front of heater (inches)

Page 13 of the Procom MD100TBA user manual — INSTALLATION
Page 13 · click to enlarge
Page 13

FASTENING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater (see Figure 5). It has been taped there for shipping. Remove mounting bracket from back panel.

Procom MD100TBA — INSTALLATION diagram (page 13)
Fig. 8

Removing Front Panel of Heater 1. Remove two screws near bottom corners of lower front panel .

2. Pull bottom of lower front panel forward, then down (see Figure 6).

Figure 5 - Mounting Bracket Location

Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mounting bracket to attach bracket to wall. Attach mounting bracket to a wall only in one of two ways: 1. Attaching to wall stud: This method provides the strongest hold.

Procom MD100TBA — INSTALLATION diagram (page 13)
Fig. 9

Insert mounting screws through mounting bracket and into wall studs.

2. Attaching to wall anchor: This method allows you to attach mounting

bracket to hollow walls (wall areas between studs) or to solid walls

(concrete or masonry).

3. Decide which method better suits your needs. Either method will provide

a secure hold for the mounting bracket.

Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located.

Figure 6 - Mounting Bracket

Make sure mounting bracket is level.

and joining wall.

2. Mark screw locations on wall (see Figure 7).
3. Remove tape and mounting bracket from wall.
Procom MD100TBA — INSTALLATION diagram (page 13)
Fig. 10

Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method For attaching mounting bracket to wall studs: 1. Drill holes at marked locations using 9/64-inch drill bit.

ModelMD100TBA MD100HBA
2. Place mounting bracket onto wall. Line up last hole on

each end of bracket with holes drilled in wall.

Procom MD100TBA — INSTALLATION diagram (page 13)
Fig. 11
3. Insert mounting screws through bracket and into wall studs.
4. Tighten screws until mounting bracket is firmly fastened to wall studs.
ModelMD200TBA MD200HBA MD300TBA MD300HBA MD200TBA-BB MD200HBA-BB MD300TBA-BB MD300HBA-BB

Figure 7 - Mounting Bracket

Clearances (inches) · Clearances (inches)

Page 14 of the Procom MD100TBA user manual — INSTALLATION
Page 14 · click to enlarge
Page 14

Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry): 1. Drill holes at marked locations using 5/16-inch drill bit. For solid walls (concrete or masonry), drill at least 1 inch deep.

Procom MD100TBA — INSTALLATION diagram (page 14)
Fig. 12
2. Fold wall anchor as shown in Figure 8.
3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

Figure 8 - Folding Anchor

4. For thin walls (1/2 inch or less), insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 9).
Procom MD100TBA — INSTALLATION diagram (page 14)
Fig. 13

1/2 inch thick) or solid walls, do not pop open wings.

5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.
6. Insert mounting screws through bracket and into wall anchors.

Figure 9 - Popping Open Anchor Wing For Thin Walls

7. Tighten screws until mounting bracket is firmly fastened to wall.

Placing Heater On Mounting Bracket 1. Locate two horizontal slots on back panel of heater (see Figure 10).

Procom MD100TBA — INSTALLATION diagram (page 14)
Fig. 14
2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Installing Bottom Mounting Bracket 1. Install bottom bracket to heater bottom with two screws. It may be more convenient to remove heater from wall bracket to

attach.

2. Place heater on wall mounting bracket.
3. Mark screw locations on wall.

Figure 10 - Mounting Heater

4. Remove heater from mounting bracket.
5. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under “Attaching To Wall Anchor Method”. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64-inch drill bit.
Procom MD100TBA — INSTALLATION diagram (page 14)
Fig. 15
6. Replace heater onto mounting bracket.
7. Tighten both screws until heater is firmly secured to wall. Do not over-tighten.

Figure 11 - Installing Bottom

Onto Mounting Bracket · Mounting Bracket

Page 15 of the Procom MD100TBA user manual — NATURAL GAS MODELS:
Page 15 · click to enlarge
Page 15

CONNECTING TO GAS SUPPLY

regulator.

Check your local codes. Use pipe of 1/2-in. diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

NATURAL GAS MODELS:

greater than 10.5 inches of water. If gas line pressure is higher, heater regulator damage could occur.

pROPANE MODELS:

fittings.

Typical Inlet Pipe Diameters Use 3/8-inch black iron pipe or greater. Installation must include an equipment shutoff valve, union, and plugged 1/8-inch NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 12).

Procom MD100TBA — NATURAL GAS MODELS: diagram (page 15)
Fig. 16

Figure 12 - Gas Connection (inches)

* Purchase the optional CSA design-certified equipment shutoff valve from your dealer.

Page 16 of the Procom MD100TBA user manual — INSTALLATION
Page 16 · click to enlarge
Page 16
Procom MD100TBA — Continued diagram (page 16)
Fig. 17 · Continued

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

Install sediment trap in supply line as shown in Figure 12. Place sediment trap where it is within reach for cleaning. Place sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Figure 13 - External Regulator with

INSTALLATION

Continued

CAUTION: Two gas line installation at the same time is forbidden. Do not the open cover while the heater is running. Heater is pre-set at factory for propane gas; no changes are required for connecting to propane. Only a qualified installer or service technician can perform gas selection and connecting to gas supply. CAUTION: To avoid gas leakage at the inlet of regulator, a qualified installer or service technician must use steel or metal hex plug with sealant.

For changing from propane to natural gas supply:

1. Remove top screw from cover plate, See Figure 14, and rotate to expose gas selection valve.
2. For NATURAL GAS, press knob using a flat screwdriver with a blade with thickness of a quarter and turn knob counterclockwise until the knob locks into the NG position (see Figure 15). Selection valve must be locked in the NG position. Do not operate heater between locked positions!
3. Rotate and close cover over gas selection valve and reinstall screw.
4. Remove steel or metal hex plug (with wrench provided) from natural gas inlet of regulator and install into LP inlet of regulator; use thread sealant to ensure that there are no leaks.

For changing from natural gas supply to propane supply:

1. Remove top screw from cover plate, See Figure 14, and rotate to expose gas selection valve.
2. For propane gas, press in knob using a flat screwdriver with a blade the thickness of a quarter and turn knob clockwise until the knob locks into the LP position, see Figure 16. Selection valve must be locked in the LP position. Do not operate heater between locked positions.
3. Rotate and close cover over gas selection valve and reinstall screw.
4. Remove steel or metal hex plug from liquid propane inlet of regulator and install into NG inlet of regulator; use thread sealant to assure there are no leaks.

Vent Pointing Down

Page 17 of the Procom MD100TBA user manual — CHECKING GAS CONNECTIONS
Page 17 · click to enlarge
Page 17

Figure 14 Figure 15 Figure 16

CHECKING GAS CONNECTIONS

bubbles form, there is a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5kPa) 1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.

2. Cap off open end of gas pipe where equipment shutoff valve was connected.
3. Pressurize supply piping system by either using compressed air or opening
Procom MD100TBA — CHECKING GAS CONNECTIONS diagram (page 17)
Fig. 18

gas supply valve.

4. Check all joints of gas supply piping system. Apply mixture of liquid soap

and water to gas joints. If bubbles form, there may be a leak.

5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve to gas suply. Check

Figure 17 - Equipment Shutoff Valve

reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

Procom MD100TBA — CHECKING GAS CONNECTIONS diagram (page 17)
Fig. 19
1. Close equipment shutoff valve (see Figure 17).
2. Pressurize supply piping system by either using compressed air or

opening natural supply tank valve.

3. Check all joints from gas meter to equipment shutoff valve

(see Figure 18).

Apply mixture of liquid soap and water to gas joints. If bubbles

form, there is a leak.

4. Correct all leaks at once.

Figure 18 - Fuel Supply

Page 18 of the Procom MD100TBA user manual — WHAT TO DO IF YOU SMELL GAS
Page 18 · click to enlarge
Page 18

Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 17).

2. Open gas supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Remove front panel.
5. Check all joints from equipment shutoff valve to control valve (see Figure 17). Apply mixture of liquid soap and water to gas joints. If bubbles form, there may be a leak.
6. Correct all leaks at once.
7. Light heater (see Lighting Instructions on page 19 ). Check all other internal joints for leaks.
8. Turn off heater (see “To Turn Off Gas Appliance” on page 18).
9. Replace lower front panel.

operation

FOR YOUR SAFETY READ BEFORE LIGHTING

damage, personal injury or loss of life.

A.

When lighting the pilot, follow these instructions exactly.

B.

BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because

some gas is heavier than air and will settle on the floor.

Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn

by hand, don’t try to repair it, call a qualified service technician or gas supplier. Forced or attempted repair may result in a fire or explosion.

D.

Do not use this appliance if any part has been under water. Immediately call a qualified service technician to

inspect the appliance and to replace any part of the control system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance. Do not touch any electric switch, do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.

Page 19 of the Procom MD100TBA user manual — Lighting INSTRUCTIONS
Page 19 · click to enlarge
Page 19

Lighting INSTRUCTIONS

MD100TBA & MD200TBA & MD300TBA & MD200TBA-BB & MD300TBA-BB

Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap.

1. STOP! Read the safety information on the side of the heater.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise

to the OFF position.

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Do not try to light any appliance. Do not touch electrical switch or use any phone in the building. Immediately contact gas supplier from a neighbor’s phone. Follow gas supplier’s instructions. If you can’t reach the gas supplier, call the fire dept. If you don’t smell gas, go to the next step.
5. Turn control knob counterclockwise

to the PILOT position.Press in control knob for five (5) seconds (see Figure 19).

for about thirty (30) seconds.This will allow air to bleed from the gas sysystem. If pilot does not stay lit, refer to Troubleshooting, pages 23 through 24. Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match.

  • If control knob does not pop up when released, contact a qualified service technician or gas supplier for repairs.

6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the gill. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, refer to Troubleshooting, pages 23 through 24. Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see “Manual Lighting Procedure”.

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. If control knob does not pop up when released, contact a qualified service technician or gas supplier for repairs. Note : If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.
8. Turn control knob counterclockwise

to desired heating level. The main burner should light. Set control knob to any heat level between 1 and 5.

THERMOSTAT CONTROL OPERATION The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn the burner on and off. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level between 1 and 5.

TO TURN OFF GAS TO APPLIANCE Shutting Off Heater Turn control knob clockwise

Figure 19 - Control Knob in the

to the OFF position.

Shutting Off Burner Only (pilot stays lit ) Turn control knob clockwise

to the PILOT position.

OFF Position

Page 20 of the Procom MD100TBA user manual — MANUAL LIGHTING
Page 20 · click to enlarge
Page 20

Lighting INSTRUCTIONS

MD100HBA & MD200HBA & MD300HBA & MD200HBA-BB & MD300HBA-BB

1. STOP! Read the safety information on the side of heater.
2. Check that gas supply to heater is on.
3. Push in gas control knob slightly and turn clockwise

to the OFF position.

4. Wait five (5) minutes to clear out any air. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow "B" in the safety information on the side of the heater. If you do not smell

gas, go to the next step.

5. Push in gas control knob slightly and turn counterclockwise

to "PILOT/IGN" and depress for five (5) seconds

depressed for about thirty (30) seconds. This will allow air to bleed from the gas system.

6. With control knob pressed in, push down and release the ignitor button. This will light pilot. If needed, keep

pressing ignitor button until pilot lights.

7. Keep control knob depressed for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 5,6 and 7.
8. To select the desired heating level, partially press down the control knob slightly and rotate counterclockwise

Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting

position. Do not operate between locked positions. Set control knob to desired heating position.

positions.

Procom MD100TBA — Lighting INSTRUCTIONS diagram (page 20)
Fig. 20 · Lighting INSTRUCTIONS

Figure 20 - Control Knob in the

TO TURN OFF GAS TO APPLIANCE

1. Turn control knob clockwise

to the OFF position.

2. Turn off all electric power to the appliance if service is to be performed.

SHUTTING OFF BURNER ONLY

(PILOT STAYS LIT)

Turn control knob clockwise

to the PILOT/IGN position.

MANUAL LIGHTING

PROCEDURE

1. Remove lower front panel.
2. Follow steps 1 through 5 under Lighting Instructions.
3. With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow

step 8 under Lighting Instructions.

5. Replace lower front panel.

OFF Position · Shutting Off Heater

Page 21 of the Procom MD100TBA user manual — PILOT FLAME PATTERN
Page 21 · click to enlarge
Page 21

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 21 shows a correct pilot flame pattern. Figure 22 shows a incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool, which shuts the heater off. If

pilot flame pattern is incorrect:

turn heater off (see “To Turn Off Gas to Appliance” on page 19) see Troubleshooting pages 23 through 25.

Procom MD100TBA — PILOT FLAME PATTERN diagram (page 21)
Fig. 21
Procom MD100TBA — PILOT FLAME PATTERN diagram (page 21)
Fig. 22

Figure 21 - Correct Pilot Flame Pattern Figure 22 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN Figure 23 shows a correct burner flame pattern. Figure 24 shows an incorrect burner flame pattern. If burner flame pattern is incorrect then:

turn heater off (see “To Turn Off Gas to Appliance” on page 19). see Troubleshooting, pages 23 through 25.

Procom MD100TBA — PILOT FLAME PATTERN diagram (page 21)
Fig. 23
Procom MD100TBA — PILOT FLAME PATTERN diagram (page 21)
Fig. 24

Figure 23 - Correct Burner Flame Pattern Figure 24 - Incorrect Burner Flame Pattern

Page 22 of the Procom MD100TBA user manual — CABINET Air Passageways
Page 22 · click to enlarge
Page 22

CARE AND MAINTENANCE

these areas of heater before each use. Have heater inspected yearly by a qualified service technician. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

ODS/PILOT AND BURNER

Use a vacuum cleaner, pressurized air, or a small, soft bristled brush to clean.

CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit every 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSl. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly.

1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.
2. Inspect burner and pilot for dust and dirt.

3. Blow air through the ports/slots and holes in the burner. Also clean the pilot assembly. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 25). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

CABINET Air Passageways

Use a vacuum cleaner or pressurized air to clean. Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

Procom MD100TBA — CABINET Air Passageways diagram (page 22)
Fig. 25 · CABINET Air Passageways

Figure 25 - Pilot Inlet Air Hole

Page 23 of the Procom MD100TBA user manual — PROBLEM
Page 23 · click to enlarge
Page 23

troubleshooting

Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.

mover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed in there is no spark at ODS/pilot.

1. Ignitor electrode is positioned wrong or broken. 2. Ignitor electrode is not connected to ignitor cable. 3. Ignitor cable is pinched or wet.
1. Replace ignitor.
2. Reconnect ignitor cable.
3. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry. 4. Replace ignitor cable. 5. Replace piezo ignitor.
4. Broken ignitor cable. 5. Bad piezo ignitor.
1. Gas supply is turned off or equipment shutoff valve is closed. 2. Control knob not fully pressed in while pressing ignitor button. 3. Air in gas lines when installed.
1. Turn on gas supply or open equipment shutoff valve. 2. Fully press in control knob while pressing ignitor button. 3. Continue holding down control knob. Repeat igniting operation until air is removed. 4. Clean ODS/pilot (see Care and Maintenance , page 22) or replace ODS/ pilot assembly. 5. Replace gas regulator. 6. Turn control knob to PILOT position. 7. Contact local propane/LP gas company.

When ignitor button is pressed in there is a spark at ODS/pilot but no ignition.

4. ODS/pilot is clogged.
5. Gas regulator setting is not correct. 6. Control knob not in PILOT position. 7. Depleted gas supply (propane).
1. Control knob is not fully pressed in. 2. Control knob is not pressed in long enough. 3. Equipment shutoff valve is not fully open. 4. Thermocouple connection is loose at control valve. 5. Thermocouple damaged. 6. Control valve damaged.
1. Press in control knob fully. 2. After ODS/pilot lights, keep control knob pressed in 30 seconds. 3. Fully open equipment shutoff valve

ODS/pilot lights but flame goes out when control knob is released.

4. Hand tighten until snug, and then tighten 1/4 turn more. 5. Replace thermocouple. 6. Contact customer service.
Page 24 of the Procom MD100TBA user manual — PROBLEM
Page 24 · click to enlarge
Page 24

troubleshooting

PROBLEM

POSSIBLE CAUSE

POSSIBLE CAUSE

1. Burner orifice is clogged.
1. Clean burner orifice (see Care and Maintenance , page 22) or replace burner orifice. 2. Contact customer service.

Burner(s) does not light after ODS/pilot is lit.

2. Burner orifice diameter is too small.
3. Inlet gas pressure is too low.
3. Contact local gas supplier.
1. Manifold pressure is too low.
1. Contact local gas supplier. 2. Clean burner (see Care and Maintenance , page 22) or replace burner orifice.

Delayed ignition of burner(s).

2. Burner orifice is clogged.
1. Burner orifice is clogged or damaged.
1. Clean burner orifice (see Care and Maintenance , page 22) or replace. 2. Contact customer service.

Burner backfiring during combustion.

2. Burner is damaged.
3. Gas regulator is defective.
3. Replace gas regulator.
1. Not enough air.
1. Check burner for dirt and debris. If found, clean burner (see Care and Maintenance , page 22). 2. Replace gas regulator.

Yellow flame during burner combustion.

2. Gas regulator is defective.
3. Inlet gas pressure is too low.
3. Contact local gas supplier.
1. Problem will stop after a few hours of operation.

Slight smoke or odor during initial operation.

1. Residues from manufacturing processes.
1. Turning control knob to HI position when burner is cold. 2. Air in gas line.
1. Turn control knob to LO position and let warm up for a minute. 2. Operate burner until air is removed from line. Have gas line checked by local gas supplier. 3. Observe minimum installation clearances (Figure 4, page 12). 4. Clean burner (see Care and Maintenance , page 22) or replace burner orifice.

Heater produces a whistling noise when burner is lit.

3. Air passageways on heater are blocked.
4. Dirty or partially clogged burner orifice.

Heater produces a clicking/ ticking noise just after burner is lit or shut off.

1. Metal is expanding while heating or contracting while cooling.
1. This is common with most heaters. if noise is excessive, contact qualified service technician.
1. When heated, the vapors from furniture polish, wax, carpet cleaners, etc., turn into white powder residue.
1. Turn heater off when using furniture polish, wax, carpet cleaner, or similar products.

White powder residue forming within burner box or on adjacent walls or furniture.

Page 25 of the Procom MD100TBA user manual — PROBLEM
Page 25 · click to enlarge
Page 25

PROBLEM

REMEDY

POSSIBLE CAUSE

1. Heater is burning vapors from paint, hair spray, glues, etc. See IMPORTANT statement page 23. 2. Gas leak. See Warning Statement at the top of page 23. 3. Low fuel supply.
1. Ventilate room. Stop using odor causing products while heater is running.

Heater produces unwanted odors.

2. Locate and correct all leaks (see Checking Gas Connections, page 17).
3. Refill supply tank (Propane / LP models).
1. Not enough fresh air is available.
1. Open window and/or door for ventilation. 2. Contact local gas supplier. 3. Clean ODS/pilot (see Care and Maintenance , page 22).

Heater shuts off in use (ODS operates).

2. Low line pressure. 3. ODS/pilot is partially clogged.
1. Gas leak. See Warning Statement at top of page 23.
1. Locate and correct all leaks (see “Checking Gas Connections”, page 16). 2. Contact customer service.

Gas odor exists even when control knob is in OFF position.

2. Control valve is defective.
1. Foreign matter between control valve and burner. 2. Gas leak. See Warning Statement at top of page 23.
1. Take apart gas tubing and remove foreign matter. 2. Locate and correct all leaks (see “Checking Gas Connections”, page 17).

Gas odor during combustion.

Moisture/condensation noticed on windows.

1. Not enough combustion/ventilation air.
1. Refer to "Air for Combustion and Ventilation” requirements, page 9.
Page 26 of the Procom MD100TBA user manual — FLOOR MOUNTING STAND
Page 26 · click to enlarge
Page 26

important SAFETY INFORMATION

REPLACEMENT PARTS

warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement parts, call Customer Service toll

free at (877)886-5989 for referral information.

When calling Customer Service or your dealer, have ready:

  • Your name
  • Your address
  • Model and serial number of your heater
  • How heater was malfunctioning
  • Type of gas used (Propane/LP or Natural gas/NG)
  • Purchase date
  • Usually, we will ask you to return the defective part to the factory

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call Customer Service

toll free at (877)886-5989 for referral information.

Procom MD100TBA — PARTS NOT UNDER WARRANTY diagram (page 26)
Fig. 26

When calling Customer Service have ready:

  • Model number of your heater
  • The replacement part number

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these accessories, contact PRO-COM for information.

Procom MD100TBA — ACCESSORIES diagram (page 26)
Fig. 27

EQUIPMENT SHUTOFF VALVE For all models. Equipment shutoff valve with 1/8 in. NPT tap. (see figure 1)

The optional fan kit, part PF06-YJLF-B fits (model #

MD200TBA, MD300TBA, MD200HBA, MD300HBA,

MD200TBA-BB, MD300TBA-BB, MD200HBA-BB

MD300HBA-BB). The fan has 3 settings ON/OFF/Auto.

Please refer to PF06-YJLF-B instructions. (see figure 2)

Procom MD100TBA — MD200TBA, MD300TBA, MD200HBA, MD300HBA, diagram (page 26)
Fig. 28

FLOOR MOUNTING STAND

For locating heater on the floor, away from a wall. Complete

installation instructions provided with floor

mounting stand. (see figure 3)

Show 5 more labels / short text on this page
figure 1 · Optional FAN Kit · figure 2 · figure 3 · 26 26 26
Page 27 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 27 · click to enlarge
Page 27
Procom MD100TBA — REPLACEMENT PARTS diagram (page 27)
Fig. 29

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.

Page 28 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 28 · click to enlarge
Page 28
Procom MD100TBA — REPLACEMENT PARTS diagram (page 28)
Fig. 30
Page 29 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 29 · click to enlarge
Page 29
Procom MD100TBA — REPLACEMENT PARTS diagram (page 29)
Fig. 31

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.

19 MDL304B MDL304B Change Gas Type Valve Knob 1

Page 30 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 30 · click to enlarge
Page 30
Procom MD100TBA — REPLACEMENT PARTS diagram (page 30)
Fig. 32
Page 31 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 31 · click to enlarge
Page 31
Procom MD100TBA — REPLACEMENT PARTS diagram (page 31)
Fig. 33

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.

Page 32 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 32 · click to enlarge
Page 32
Procom MD100TBA — REPLACEMENT PARTS diagram (page 32)
Fig. 34
Page 33 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 33 · click to enlarge
Page 33
Procom MD100TBA — REPLACEMENT PARTS diagram (page 33)
Fig. 35

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.

24 MDL304B MDL304B Change Gas Type Valve Knob 1

Page 34 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 34 · click to enlarge
Page 34
Procom MD100TBA — REPLACEMENT PARTS diagram (page 34)
Fig. 36
Page 35 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 35 · click to enlarge
Page 35
Procom MD100TBA — REPLACEMENT PARTS diagram (page 35)
Fig. 37

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.

19 MDL304B MDL304B Change Gas Type Valve Knob 1

Page 36 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 36 · click to enlarge
Page 36
Procom MD100TBA — REPLACEMENT PARTS diagram (page 36)
Fig. 38
Page 37 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 37 · click to enlarge
Page 37
Procom MD100TBA — REPLACEMENT PARTS diagram (page 37)
Fig. 39

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.

24 MDL304B MDL304B Change Gas Type Valve Knob 1

Page 38 of the Procom MD100TBA user manual — REPLACEMENT PARTS
Page 38 · click to enlarge
Page 38
Procom MD100TBA — REPLACEMENT PARTS diagram (page 38)
Fig. 40

Ask about the Procom MD100TBA

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Procom MD100TBA

Be the first to ask — other owners or our team will answer.

Original document

Procom MD100TBA manual PDF

38 pages·1.6 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…