Blue Flame
MD200TBA MD300TBA MD100HBA MD200HBA MD300HBA MD200TBA-BB MD300TBA-BB MD200HBA-BB MD300HBA-BB

-- Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.
-- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air For Combustion and Ventilation section on page 9 of this manual.
INSTALLER: DO NOT DISCARD THIS MANUAL – LEAVE FOR HOMEOWNER’S FUTURE REFERENCE.
This appliance may be installed in an aftermarket, permanently located manufactured (mobile) home, where not prohibited by local codes. This appliance is for use with the type of gas indicated on the rating plate only. This appliance is not convertible for use with other gases.
Questions about installation, operation, or troubleshooting? Before returning to your retailer, call customer service department toll-free at (877)886-5989.






Only a qualified installer, service agent, or local gas supplier may install and service this product.
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning resemble the flu with headache, dizziness and/or nausea. If you have these signs, heater may not be working properly. Get fresh air at once! Have heater serviced. Some people - pregnant women, persons with heart or lung disease, anemia, those under the influence of alcohol, those at high altitude - are more affected by carbon monoxide than others.
Natural and Propane/LP Gas: Natural and Propane/LP gas are odorless. An odor-producing agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
convertible for use with other gases.
outdoors.
the appliance.
safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for
Combustion and Ventilation, pages 9 through 11. If heater keeps shutting off, see Troubleshooting, pages 23
through 25.
proper combustion.

serviced.
these products may create a white powder residue within burner box or on adjacent walls or furniture.
tween locked positions. Poor combustion and higher levels of carbon monoxide may result.
the room heater and to replace any part of the control system and any gas control which has been under water.
11.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair
heater.
QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping, gas utilization equipment or accessories, and repair and equipment servicing.The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping or
b) Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirement of the authority having jurisdiction.
• •

SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM This heater is equipped with an electronic piezo control system. This system requires AAA batteries (provided).
2 GAS OPTIONS CAPABLE Your heater is equipped to operate on either Propane or Natural gas. The heater is shipped from the factory ready for connecting to Propane. The heater can easily be changed to Natural gas by having your qualified installer follow the instructions on page 15 and the markings on the heater.
THERMOSTATIC CONTROL ON THERMOSTAT MODEL These heaters have a control valve with a thermostat sensing bulb. This results in the greatest heater comfort and may result in lower gas bills.
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane or natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.
In the State of Massachusetts the gas cock must be a T-handle type. The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/ NFPA 54.
*Available from:
American National Standards Institute, lnc. 1430 Broadway New York, NY 10018
National Fire Protection Association, lnc. 1 Batterymarch Park Quincy, MA 02269-9101

Before beginning assembly or operation of the product, make sure all parts are present. Compare parts with package contents list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for replacement parts. Before installing heater, make sure you have the items listed below:
piping (check local codes) sealant (resistant to natural gas and propane/LP gas) equipment shutoff valve* test gauge connection* sediment trap tee joint pipe wrench flexible gas hose (check local codes)

* A CSA design-certified equipment shutoff valve with 1/8-inch NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design- certified equipment shutoff valve from your dealer.
UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipping 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
Figure 1 - Vent-Free Gas Heater
Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30 mL) of water for every 1,000 BTUs (.3 KWs) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applica- tions, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather. The following steps will help ensure that water vapor does not become a problem.

Providing Adequate Ventilation This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54, the INTERNATIONAL FUEL GAS CODE, or applicable local codes. The following are excerpts from National Fuel Gas Code, ANSI Z223.1/ NFPA 54. Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 9 through 11 will help you classify your space and provide adequate ventilation.
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cu. ft. per 1,000 BTU/hr (4.8 m^3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 BTU/hr (4.8 m^3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms connecting directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
* Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them.
Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where:
Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of
one perm (6×10-11kg per pa-sec-m2) or less with openings gasketed or sealed and
Weather stripping has been added on openable windows and on doors and
Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates
and floors, between wall ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide additional fresh air. See “Ventilation Air From
Outdoors”. If your home does not meet all of the three criteria above, proceed to “Determining Fresh-Air Flow For
Heater Location”.
a) · b) · c)

Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
Example: Space size 20 ft. (length) × 16 ft. (width)×8 ft. (ceiling height) =2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to
the total volume of the space.
(volume of space) ÷ 50 cu. ft. =(Maximum BTU/hr the space can support)
BTU/hr
Other gas appliances* +
*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the
outdoors.
BTU/hr (maximum the space can support)
BTU/hr (actual amount of BTU/hr used)
56,000 BTU/hr (actual amount of BTU/hr used)
The space in the above example is a confined space because the actual BTU/hr used is more than the maximum BTU/ hr the space can support.
You must provide additional fresh air. Your options are as follows:
Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space,
remove door to adjoining room or add ventilation grills between rooms. See “ Ventilation Air From Inside Building ” on next page.
Vent room directly to the outdoors. See “ Ventilation Air From Outdoors ” on next page.
c) Install a lower BTU/hr heater if lower BTU/hr size makes room unconfined. If the actual BTU/hr used is less than the maximum BTU/hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.


Ventilation Air From lnside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12 inches of the ceiling and one within 12 inches of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove the door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code. ANSI Z223.1/ NFPA 54, Air for Combustion and Ventilation for required size of entilation grills or ducts.
Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12 inches of the ceiling and one within 12 inches of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 3 - Ventilation Air from Outdoors

system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
Heater pilot and burner must be at least 18 inches above the floor. Place heater where moving vehicle will not hit it.
in a bedroom or bathroom in a recreational vehicle where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater in high traffic areas in windy or drafty areas
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form too much moisture. See Air for Combustion and Ventilation, pages 9 through 11. Check Gas Type Be sure your gas supply is right for your heater. Otherwise, call dealer where you bought the heater for proper type heater.

Clearances To Combustibles Carefully follow the instructions below. This heater is a freestanding unit designed to be mounted on a wall or set directly on the floor.
LOCATING HEATER This heater is designed to be mounted on a wall. For convenience and efficiency, install heater: 1) where there is easy access for operation, inspection, and service. 2) In the coldest part of room.
Figure 4 - Mouting clearances as viewed from
front of heater (inches)

FASTENING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater (see Figure 5). It has been taped there for shipping. Remove mounting bracket from back panel.

Removing Front Panel of Heater 1. Remove two screws near bottom corners of lower front panel .
Figure 5 - Mounting Bracket Location
Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mounting bracket to attach bracket to wall. Attach mounting bracket to a wall only in one of two ways: 1. Attaching to wall stud: This method provides the strongest hold.

Insert mounting screws through mounting bracket and into wall studs.
bracket to hollow walls (wall areas between studs) or to solid walls
(concrete or masonry).
a secure hold for the mounting bracket.
Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located.
Figure 6 - Mounting Bracket
Make sure mounting bracket is level.
and joining wall.

Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method For attaching mounting bracket to wall studs: 1. Drill holes at marked locations using 9/64-inch drill bit.
each end of bracket with holes drilled in wall.

Figure 7 - Mounting Bracket
Clearances (inches) · Clearances (inches)

Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry): 1. Drill holes at marked locations using 5/16-inch drill bit. For solid walls (concrete or masonry), drill at least 1 inch deep.

Figure 8 - Folding Anchor

1/2 inch thick) or solid walls, do not pop open wings.
Figure 9 - Popping Open Anchor Wing For Thin Walls
Placing Heater On Mounting Bracket 1. Locate two horizontal slots on back panel of heater (see Figure 10).

Installing Bottom Mounting Bracket 1. Install bottom bracket to heater bottom with two screws. It may be more convenient to remove heater from wall bracket to
attach.
Figure 10 - Mounting Heater

Figure 11 - Installing Bottom
Onto Mounting Bracket · Mounting Bracket

regulator.
Check your local codes. Use pipe of 1/2-in. diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.
greater than 10.5 inches of water. If gas line pressure is higher, heater regulator damage could occur.
pROPANE MODELS:
fittings.
Typical Inlet Pipe Diameters Use 3/8-inch black iron pipe or greater. Installation must include an equipment shutoff valve, union, and plugged 1/8-inch NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 12).

Figure 12 - Gas Connection (inches)
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer.


Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.
Install sediment trap in supply line as shown in Figure 12. Place sediment trap where it is within reach for cleaning. Place sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Figure 13 - External Regulator with
Continued
CAUTION: Two gas line installation at the same time is forbidden. Do not the open cover while the heater is running. Heater is pre-set at factory for propane gas; no changes are required for connecting to propane. Only a qualified installer or service technician can perform gas selection and connecting to gas supply. CAUTION: To avoid gas leakage at the inlet of regulator, a qualified installer or service technician must use steel or metal hex plug with sealant.
For changing from propane to natural gas supply:
For changing from natural gas supply to propane supply:
Vent Pointing Down

Figure 14 Figure 15 Figure 16
bubbles form, there is a leak. Correct all leaks at once.
Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5kPa) 1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.

gas supply valve.
and water to gas joints. If bubbles form, there may be a leak.
Figure 17 - Equipment Shutoff Valve
reconnected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

opening natural supply tank valve.
(see Figure 18).
Apply mixture of liquid soap and water to gas joints. If bubbles
form, there is a leak.
Figure 18 - Fuel Supply

Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 17).
damage, personal injury or loss of life.
A.
When lighting the pilot, follow these instructions exactly.
B.
BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn
by hand, don’t try to repair it, call a qualified service technician or gas supplier. Forced or attempted repair may result in a fire or explosion.
D.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Do not try to light any appliance. Do not touch any electric switch, do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.

MD100TBA & MD200TBA & MD300TBA & MD200TBA-BB & MD300TBA-BB
Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap.
to the OFF position.
to the PILOT position.Press in control knob for five (5) seconds (see Figure 19).
for about thirty (30) seconds.This will allow air to bleed from the gas sysystem. If pilot does not stay lit, refer to Troubleshooting, pages 23 through 24. Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match.
6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the gill. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, refer to Troubleshooting, pages 23 through 24. Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see “Manual Lighting Procedure”.
to desired heating level. The main burner should light. Set control knob to any heat level between 1 and 5.
THERMOSTAT CONTROL OPERATION The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn the burner on and off. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level between 1 and 5.
TO TURN OFF GAS TO APPLIANCE Shutting Off Heater Turn control knob clockwise
Figure 19 - Control Knob in the
to the OFF position.
Shutting Off Burner Only (pilot stays lit ) Turn control knob clockwise
to the PILOT position.
OFF Position

MD100HBA & MD200HBA & MD300HBA & MD200HBA-BB & MD300HBA-BB
to the OFF position.
If you smell gas, STOP! Follow "B" in the safety information on the side of the heater. If you do not smell
gas, go to the next step.
to "PILOT/IGN" and depress for five (5) seconds
depressed for about thirty (30) seconds. This will allow air to bleed from the gas system.
pressing ignitor button until pilot lights.
Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting
position. Do not operate between locked positions. Set control knob to desired heating position.
positions.

Figure 20 - Control Knob in the
to the OFF position.
(PILOT STAYS LIT)
Turn control knob clockwise
to the PILOT/IGN position.
PROCEDURE
step 8 under Lighting Instructions.
OFF Position · Shutting Off Heater

Check pilot flame pattern and burner flame pattern often.
Figure 21 shows a correct pilot flame pattern. Figure 22 shows a incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool, which shuts the heater off. If
pilot flame pattern is incorrect:
turn heater off (see “To Turn Off Gas to Appliance” on page 19) see Troubleshooting pages 23 through 25.


Figure 21 - Correct Pilot Flame Pattern Figure 22 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN Figure 23 shows a correct burner flame pattern. Figure 24 shows an incorrect burner flame pattern. If burner flame pattern is incorrect then:
turn heater off (see “To Turn Off Gas to Appliance” on page 19). see Troubleshooting, pages 23 through 25.


Figure 23 - Correct Burner Flame Pattern Figure 24 - Incorrect Burner Flame Pattern

these areas of heater before each use. Have heater inspected yearly by a qualified service technician. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.
Use a vacuum cleaner, pressurized air, or a small, soft bristled brush to clean.
CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit every 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSl. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly.
3. Blow air through the ports/slots and holes in the burner. Also clean the pilot assembly. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 25). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Use a vacuum cleaner or pressurized air to clean. Exterior
Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

Figure 25 - Pilot Inlet Air Hole

Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.
mover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed in there is no spark at ODS/pilot.
When ignitor button is pressed in there is a spark at ODS/pilot but no ignition.
ODS/pilot lights but flame goes out when control knob is released.

POSSIBLE CAUSE
POSSIBLE CAUSE
Burner(s) does not light after ODS/pilot is lit.
Delayed ignition of burner(s).
Burner backfiring during combustion.
Yellow flame during burner combustion.
Slight smoke or odor during initial operation.
Heater produces a whistling noise when burner is lit.
Heater produces a clicking/ ticking noise just after burner is lit or shut off.
White powder residue forming within burner box or on adjacent walls or furniture.

REMEDY
POSSIBLE CAUSE
Heater produces unwanted odors.
Heater shuts off in use (ODS operates).
Gas odor exists even when control knob is in OFF position.
Gas odor during combustion.
Moisture/condensation noticed on windows.

REPLACEMENT PARTS
warranty.
Contact authorized dealers of this product. If they can’t supply original replacement parts, call Customer Service toll
free at (877)886-5989 for referral information.
When calling Customer Service or your dealer, have ready:
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call Customer Service
toll free at (877)886-5989 for referral information.

When calling Customer Service have ready:
Purchase these heater accessories from your local dealer. If they can not supply these accessories, contact PRO-COM for information.

EQUIPMENT SHUTOFF VALVE For all models. Equipment shutoff valve with 1/8 in. NPT tap. (see figure 1)
The optional fan kit, part PF06-YJLF-B fits (model #
MD200TBA-BB, MD300TBA-BB, MD200HBA-BB
MD300HBA-BB). The fan has 3 settings ON/OFF/Auto.
Please refer to PF06-YJLF-B instructions. (see figure 2)

For locating heater on the floor, away from a wall. Complete
installation instructions provided with floor
mounting stand. (see figure 3)


This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.




This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
19 MDL304B MDL304B Change Gas Type Valve Knob 1




This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.




This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
24 MDL304B MDL304B Change Gas Type Valve Knob 1




This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
19 MDL304B MDL304B Change Gas Type Valve Knob 1




This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
24 MDL304B MDL304B Change Gas Type Valve Knob 1