EN
Official user manual

LST Fire Alarm Control Panel (BC016-1)

3 pages·264 KB·Smoke Alarm·PDF·ENDEFRITNLJA
LST Fire Alarm Control Panel (BC016-1)
Table of Contents 6 sections Fire Detection Control Panel · BC016-1 · Description · Clear Concept · … ShowHide
Page 1 of the LST Fire Alarm Control Panel (BC016-1) user manual — Description
Page 1 · click to enlarge
Page 1
LST Fire Alarm Control Panel (BC016-1) — Fire Detection Control Panel diagram (page 1)
Fig. 1 · Fire Detection Control Panel

Fire Detection Control Panel

LST Fire Alarm Control Panel (BC016-1) — Fire Detection Control Panel diagram (page 1)
Fig. 2 · Fire Detection Control Panel
LST Fire Alarm Control Panel (BC016-1) — Fire Detection Control Panel diagram (page 1)
Fig. 3 · Fire Detection Control Panel
LST Fire Alarm Control Panel (BC016-1) — Fire Detection Control Panel diagram (page 1)
Fig. 4 · Fire Detection Control Panel

BC016-1

  • For application in small and mid-sized systems
LST Fire Alarm Control Panel (BC016-1) — BC016-1 diagram (page 1)
Fig. 5
  • Addressable conventional technology with up to 16 detector zones
  • Menu-driven operation
  • Free parameter setup via PC software or operating fi eld
  • Factory settings allow for easy commissioning
  • EN 54/VdS-certifi ed

Fire is a permanent threat to life and property. There- fore, immediate response to a fi re is imperative. The main objective of the fi re detection control panel Series BC016 is to alarm and to react in time and, conse- quently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca-

ted within LST premises, thus guaranteeing fl exible and reliable individual solutions.

Using a powerful processor system, display texts, and a large number of integrated functions, the fi re detection control panels Series BC016 ensure topmost effi ciency and speed – prerequisites for saving lives and minimi- zing damage to property.

LST Fire Alarm Control Panel (BC016-1) — BC016-1 diagram (page 1)
Fig. 6

Description

Already in the basic version the fi re detection control panel BC016-1 is equipped with eight detector lines in conventional technology and, owing to its sophisticated factory settings, is immediately ready for operation. This allows for quick and effi cient application of the product. The control panel can be expanded from 8 to 16 detector zones by means of the Detector Zone Ex- tension MGE8-1.

in the fi eld of fi re alarm technology.

In addition, one slot each is available for a Fire Brigade Interface and for a Serial Interface Module, respectively. The Fire Brigade Interface FWI016-1 allows for the con- nection of country-specifi c standardized fi re brigade control units or for the expansion of the control panel with additional inputs and outputs for general control tasks.

The addressable conventional technology allows for the connection of automatic and non-automatic fi re detec- tors as well as special detectors with contact output. Unambiguous identifi cation of the activated detector in the event of an alarm facilitates the indication of the detector number on the control panel‘s display. Auxiliary outputs whose parameters can be freely set allow also for the realization and clear display of challenging tasks

Via the Serial Interface Module SIM216-1 you can address either a PC for the effi cient and clearly laid out parameterisation of the fi re detection control panel, or a printer. The Serial Interface Module SIM016-3 serves for the connection of INFO-bus devices such as fi re bri- gade control units, remote display and operating pa- nels, remote indication units, etc.

BC016-1_DBL_LST_EN_0804.PDF • PAGE 1 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 2 of the LST Fire Alarm Control Panel (BC016-1) user manual — Clear Concept
Page 2 · click to enlarge
Page 2
LST Fire Alarm Control Panel (BC016-1) — Clear Concept diagram (page 2)
Fig. 7 · Clear Concept

Clear Concept

The fi re detection control panel BC016-1 has been desi- gned for use in small and mid-sized systems and alrea- dy in its basic version provides the following features:

  • The processor-monitored power supply ensures permanent surveillance and charging of the batteries. This way, even during a power failure the untroubled and uninterrupted operation (for more than 72 hours depending on the design) is guaranteed.
  • Three hierarchized authorization levels for operation and parameterisation facilitate a high degree of security against unauthorized access.
  • The control panel is easily operated menu-driven via the display and operating fi eld. Clear instructions on the display guide the user during commissioning, operation and maintenance.
  • The parameter data can be entered either via the display and operating fi eld or, in a more comfortable way, created by means of the PC software PARSOFT-1 and loaded into the control panel. Thus, a quick and effi cient transfer of the system confi guration into the control panel is guaranteed.
  • After activation, the control panel is immediately ready for operation due to the practical factory setting. This guarantees easy and time-saving commissioning.
  • 8 conventional detector lines permit the connection of automatic detectors and manual call points in conventional technology as well as special detectors with contact output. Individual detector identifi cation can be achieved by means of an optional address module.
  • A slot for connecting the Detector Zone Extension MGE8-1 is available for the extension to 16 conventional detector lines.
  • Dry relay outputs indicate the alarm and fault conditions on the control panel. In addition, 16 open-collector outputs, two auxiliary inputs, and an additional relay output are available for general applications.
  • The optional Fire Brigade Interface FWI016-1 allows for the connection of two independent transmitting devices for a direct interconnection to a designated alarm respondent (e.g., the fi re brigade) as well as for the connection of a country-specifi c fi re brigade control unit.
  • Outputs with open parameters and logical combinations of detector zones for the activation of external controls and alarming devices allow for a maximum of fl exibility. Thus, no additional expenses arise for external relays, logic gates or timers. Thanks to the wide range of parameterisation possibilities, individual requirements even under the most diffi cult ambient conditions can be combined into a reasonable fi re protection strategy.
  • The LC text display shows all present events with date and time. This allows for quick and targeted reaction in the event of a fi re as well as for easy maintenance.
  • An event memory allows for the display of the latest 200 events at any time, including all required information. Thus, all system conditions and user operations that occurred are documented in a clearly laid out way.
  • A possible breakdown of the central processing board is securely detected and displayed by the system.

The extremely fl at wall mount cabinet allows for an easy mounting in virtually any place of the building. Thanks to its modern, ageless design, architectural requirements and demands of the respective regulations are ideally combined. The compact design allows for the accom- modation of the optional Detector Zone Extension, the Fire Brigade Interface, the Serial Interface Module, up to 3 auxiliary modules (e.g., relay module, siren connec- tion module) and batteries up to 22Ah apart from the central processing board in the standard case. Series BC016 thus stands for modularity and easy expansion.

This product complies with all relevant standards of EN 54 and is VdS-certifi ed. In addition, the product also holds several country-specifi c approvals and certifi ca- tes. LST‘s high quality level is secured by a permanent- ly monitored quality management system certifi ed by ISO 9001.

BC016-1_DBL_LST_EN_0804.PDF • PAGE 2 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 3 of the LST Fire Alarm Control Panel (BC016-1) user manual — Specifi cations
Page 3 · click to enlarge
Page 3

Permanent Connection

A variety of peripheral devices can be connected to the

fi re detection control panel BC016-1:

  • Fire brigade key safe
  • Fire brigade control unit
  • Acoustic and optical signaling devices
  • External protocol printer
  • Remote indication unit
  • Actuations
  • Modules for remote parameterisation and remote maintenance via computer newtork, modem or GSM connection – and much more.
LST Fire Alarm Control Panel (BC016-1) — Permanent Connection diagram (page 3)
Fig. 8 · Permanent Connection
LST Fire Alarm Control Panel (BC016-1) — Permanent Connection diagram (page 3)
Fig. 9 · Permanent Connection

Specifi cations

Mains voltage 230VAC +10/-15%, 50Hz

Output/nominal voltage typ. 28VDC

Output peak current max. 1.8A

Own current consumption at 24V typ. 70mA (without optional componentries)

Ambient temperature -5°C to +50°C

Relative humidity 95% (no condensation)

Dimensions W × H × D 380 × 480 × 83 (mm)

Colour gray-white, RAL 9002

Weight without accumulator approx. 5kg

Approvals (EN 54-2, EN 54-4) VdS G205023 FT 14/439/04 (Austria),

Part No. 210102

Order name Fire Detection Control Panel BC016-1/INT1

BC016-1_DBL_LST_EN_0804.PDF • PAGE 3 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LST Fire Alarm Control Panel (BC016-1)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LST Fire Alarm Control Panel (BC016-1)

Be the first to ask — other owners or our team will answer.

Original document

LST Fire Alarm Control Panel (BC016-1) manual PDF

3 pages·264 KB·Smoke Alarm·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…