BC216-1

  • For application in small and mid-sized systems
LST BC216-1 — BC216-1 diagram (page 1)
Fig. 5
  • Analogue ringbus technology with unshielded detector cabling
  • Addressable conventional technology
  • Menu-driven operation
  • Easy commissioning through AUTO setup
  • 32–bit multiprocessor system
  • EN 54/VdS-certifi ed

Fire is a permanent threat to life and property. There- fore, immediate response to a fi re is imperative. The main objective of the fi re detection control panel Series BC216 is to alarm and to react in time and, conse- quently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca-

ted within LST premises, thus guaranteeing fl exible and reliable individual solutions.

Using a 32-bit multiprocessor system, the fi re detection control panel Series BC216 ensures topmost effi ciency and speed – prerequisites for saving lives and minimi- zing damage to property.

LST BC216-1 — BC216-1 diagram (page 1)
Fig. 6

Description

The fi re detection control panel BC216-1 is designed as a modular system. According to your system‘s concept and size, it can be expanded individually.

detector zones. Addressable conventional technology allows for the connection of automatic and non-auto- matic fi re detectors as well as the unambiguous iden- tifi cation of the activated detector in the event of an alarm.

The control panel provides two slots for the connection of function modules (Conventional Detector Interface GIF8-1 or Loop Interface LIF64-1) to which a maximum of 16 detector lines in addressable conventional techno- logy or a maximum of two ADM loops or a combination of the both can be connected. In this way, you obtain the highest degree of fl exibility for virtually any task.

Depending on the respective system, a Fire Brigade In- terface FWI2-1, a Fire Brigade Interface Additional Board FWZ2-1, an LED-Display Field LAB48 as well as further optional componentries can be installed in addition.

Easy parameterisation on the control panel‘s display and operating unit, via a PC keyboard, or by means of a PC software enables you to tailor the control panel to your individual requirements.

The ADM loop principle offers intelligent analogue ring- bus technology with bi-directional data transfer. Each loop provides for the software-aided administration of up to 198 physical address points in a maximum of 128

BC216-1_DBL_LST_EN_0804.PDF • PAGE 1 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 2 of the LST BC216-1 user manual — Clear Concept
Page 2 · click to enlarge
Page 2
LST BC216-1 — Clear Concept diagram (page 2)
Fig. 7 · Clear Concept

Clear Concept

The fi re detection control panel BC216-1 constitutes the basic component of Series BC216 and has been designed for use in small and mid-sized systems. De- pending on its confi guration, it provides the following features:

  • date and time. This allows for quick and targeted reaction in the event of a fi re as well as for easy maintenance.
  • An event memory allows for the display of the latest 500 events at any time, including all required information. Thus, all system conditions and user operations that occurred are documented in a clearly laid out way.
  • At a central processing board failure, the diversifi ed redundancy concept ensures secure alarm recognition.
  • The processor-monitored power supply ensures permanent surveillance and charging of the batteries. This way, even during a mains power failure the untroubled and uninterrupted operation (for more than 72 hours depending on the design) is guaranteed.
  • Three hierarchized authorization levels for operation and parameterisation facilitate a high degree of security against unauthorized access.
  • The control panel is easily operated menu-driven via the display and operating fi eld. Clear instructions on the display guide the user during commissioning, operation and maintenance.
  • The parameter data can be entered either on the control panel via the display and operating fi eld or via a PC keyboard or, in a more comfortable way, created on a PC by means of the parameter setup software PARSOFT and loaded into the control panel. Thus, a quick and effi cient transfer of the system confi guration into the control panel is guaranteed.
  • AUTO setup facilitates parameterisation when the control panel is commissioned or expanded and thus helps to save time.
  • After commissioning, the panel‘s basic functions immediately make it ready for operation. A monitored siren output and dry relay contacts for alarm and fault are available by default.
  • The Conventional Detector Interface GIF8-1 permits the connection of automatic detectors and manual call points in conventional technology as well as special detectors with contact output. Individual detector identifi cation can be achieved by means of an optional address module.
  • Detectors and modules in ADM loop technology can be connected to the Loop Interface LIF64-1. Depending on the parameterisation, either the Apollo/Discovery protocol or the System Sensor/200 protocol is used to achieve bi-directional data transfer.
  • The BC216-1 is able to control up to 252 detectors or modules, 144 detector zones, 128 actuations, 10 transmission devices and 99 alarming devices.
  • Since the BC216-1 is compatible to LST fi re detection control panels of previous generations, the exchange or expansion of existing systems in conventional technology or ADM loop technology is possible. The existing detector installation can be used without changes.
  • The optional Fire Brigade Interface FWI2-1 serves for the connection of two independent transmitting devices for a direct interconnection to a designated alarm respondent (e.g., the fi re brigade) as well as for the connection of a country-specifi c fi re brigade control unit. By using the Fire Brigade Interface Additional Board FWZ2-1, a line supervision for both of the transmitting devices is accomplished.
  • Customizable outputs and logical combinations of detectors and detector zones for the activation of external controls and alarming devices facilitate maximum fl exibility. Thus, no additional expenses arise for external relays, logic gates or timers. Thanks to the wide range of parameterisation possibilities, individual requirements even under the most diffi cult ambient conditions can be combined into a reasonable fi re protection strategy.
  • By integrating input and output modules on any position in the loop you can realize enablements or disablements as well as control tasks in your system without having to care for additional wires.
  • The free combination of detectors and modules into logic sectors allows for the joint operation of defi ned parts of the system even beyond loop limits. Up to 199 sectors can be controlled by the BC216-1.
  • The use of unshielded loop cables allows for costsaving and uncomplicated installation as well as for the possibility of reusing the existing cabling.
  • The LC text display shows events with the full information such as fl oor, room identifi cation as well as

The fl at wall mount cabinet allows for an easy mounting in virtually any place of the building. Thanks to its mo- dern, ageless design, architectural requirements and demands of the respective regulations are ideally com- bined. The compact design allows for the accommoda- tion of the function modules, the auxiliary modules and batteries up to 22Ah apart from the central processing board in the standard case. If a higher battery capacity is needed, an auxiliary case of the same design is avai- lable. The BC216-1 thus stands for modularity and easy expansion.

This product complies with all relevant standards of EN 54 and is VdS-certifi ed. In addition, the product also holds several country-specifi c approvals and certifi ca- tes. LST‘s high quality level is secured by a permanent- ly monitored quality management system certifi ed to ISO 9001.

BC216-1_DBL_LST_EN_0804.PDF • PAGE 2 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 3 of the LST BC216-1 user manual — Extinguishing Control System
Page 3 · click to enlarge
Page 3

Permanent Connection

A variety of peripheral devices can be connected to the

fi re detection control panel BC216-1:

  • Fire brigade key safe
  • Fire brigade control unit
  • Acoustic and optical signaling devices
  • External protocol printer
  • Remote display and operating panels
  • Remote indication unit
  • Actuations
  • Electronic monitoring system
  • Transmitting device for the actuation of pagers via ESPA protocol
  • Modules for remote parameterisation and remote maintenance via computer newtork, modem or GSM connection
  • Transmitter module for the transmission of messages via SMS or e-mail – and much more.
LST BC216-1 — Permanent Connection diagram (page 3)
Fig. 8 · Permanent Connection
LST BC216-1 — Permanent Connection diagram (page 3)
Fig. 9 · Permanent Connection

Network Expansion

By upgrading the control panel, the BC216-1 can be integrated into a Global Security System network (GSSnet): the BCnet216 is a comprehensive control panel network that is made up of sectional control pa- nels Series BC216 and works as an entity beyond the boundaries of the individual loops and sectional control panels. The system is designed modularly and can be

expanded nearly without limitation, according to future demands.

The maximum size of a BCnet216 comprises 127 net- work members, 9700 detector zones, 9700 actuati- ons, 999 alarming devices as well as 99 transmitting devices.

LST BC216-1 — Network Expansion diagram (page 3)
Fig. 10 · Network Expansion

Extinguishing Control System

If required, the BC216-1 can be easily expanded to an extinguishing control panel LC216-1 according to EN 12094-1. The panel can control up to 8 fl ooding zones in one extinguishing system, without hardware redundancy. The function of the extinguishing control panel is fully

integrated into the fi re detection control panel BC216-1, a combined operation is therefore possible. The LC216-1 is certifi ed to EN 54-2, EN 54-4, EN 12094-1 and VdS as a pure extinguishing control panel and as a combined fi re detection and extinguis- hing control panel.

BC216-1_DBL_LST_EN_0804.PDF • PAGE 3 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 4 of the LST BC216-1 user manual — Specifi cations
Page 4 · click to enlarge
Page 4
LST BC216-1 — Specifi cations diagram (page 4)
Fig. 11 · Specifi cations

Specifi cations

Mains voltage 230VAC +10/-15%, 50Hz

Output voltage typ. 28VDC

Output peak current max. 1.8A

Connection of external devices typ. 0.8A, site-specifi c

Own current consumption at 24V typ. 90mA (without optional componentries)

Ambient temperature -5°C to +50°C

Dimensions W × H × D 420 × 520 × 120 (mm)

Colour gray-white, RAL 9002

Weight without accumulator approx. 6kg

Approvals (EN 54-2, EN 54-4) VdS G201017 FT 14/147/3/99 (Austria),

Order name Fire Detection Control Panel BC216-1

BC216-1_DBL_LST_EN_0804.PDF • PAGE 4 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED

Connection power 60VA

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LST BC216-1

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LST BC216-1

Be the first to ask — other owners or our team will answer.

Original document

LST BC216-1 manual PDF

4 pages·172 KB·Smoke Alarm·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…