LST BC216-1S
Table of Contents 6 sections Fire Detection Control Panel · BC216–1S · Description · Clear Concept · … ShowHide
Page 1 of the LST BC216-1S user manual — Description
Page 1 · click to enlarge
Page 1
LST BC216-1S — Fire Detection Control Panel diagram (page 1)
Fig. 1 · Fire Detection Control Panel

Fire Detection Control Panel

LST BC216-1S — Fire Detection Control Panel diagram (page 1)
Fig. 2 · Fire Detection Control Panel
LST BC216-1S — Fire Detection Control Panel diagram (page 1)
Fig. 3 · Fire Detection Control Panel
LST BC216-1S — Fire Detection Control Panel diagram (page 1)
Fig. 4 · Fire Detection Control Panel

BC216–1S

LST BC216-1S — BC216–1S diagram (page 1)
Fig. 5
  • 1-loop version of BC216-1
  • For the application in small systems
  • Analogue ringbus technology with unshielded detector cabling
  • Menu-driven operation
  • Easy commissioning through AUTO setup
  • 32–bit multiprocessor system
  • EN 54/VdS-certifi ed

Fire is a permanent threat to life and property. There- fore, immediate response to a fi re is imperative. The main objective of fi re detection control panel Series BC216 is to alarm and to react in time and, conse- quently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca-

ted within LST premises, thus guaranteeing fl exible and reliable individual solutions.

Using a 32-bit multiprocessor system, the fi re detection control panel Series BC216 ensures topmost effi ciency and speed – prerequisites for saving lives and minimi- zing damage to property.

LST BC216-1S — BC216–1S diagram (page 1)
Fig. 6

Description

The fi re detection control panel BC216–1S is designed to be used in small systems with only one ADM loop. It comprises an already completely mounted unit which includes all basic components that are needed for the operation of a 1-loop fi re detection control panel. Slot 1 is by default equipped with a Loop Interface LIF64-1 for the connection of an ADM loop, slot 2 is inoperable.

ted into the ADM loop, if required, by means of conven- tional zone modules.

Depending on the respective system, a Fire Brigade In- terface FWI2-1, a Fire Brigade Interface Additional Board FWZ2-1, an LED-Display Field LAB48 as well as further optional componentries can be installed in addition.

Easy parameterisation on the control panel‘s display and operating unit, via a PC keyboard, or by means of a PC software enables you to tailor the control panel to your individual requirements.

The ADM loop principle offers intelligent analogue ring- bus technology with bi-directional data transfer. The loop provides for the software-aided administration of up to 198 physical address points in a maximum of 128 detector zones. Conventional detectors can be integra-

BC216-1S_DBL_LST_EN_0804.PDF • PAGE 1 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 2 of the LST BC216-1S user manual — Clear Concept
Page 2 · click to enlarge
Page 2
LST BC216-1S — Clear Concept diagram (page 2)
Fig. 7 · Clear Concept

Clear Concept

Being the smallest version of the fi re detection control panel Series BC216, the BC216-1S is designed for use in small systems and provides the following features:

  • way.
  • At a central processing board failure, the diversifi ed redundancy concept ensures secure alarm recognition.
  • The processor-monitored power supply ensures permanent surveillance and charging of the batteries. This way, even during a power failure the untroubled and uninterrupted operation (for more than 72 hours depending on the design) is guaranteed.
  • Three hierarchized authorization levels for operation and parameterisation facilitate a high degree of security against unauthorized access.
  • The control panel is easily operated menu-driven via the display and operating fi eld. Clear instructions on the display guide the user during commissioning, operation and maintenance.
  • The parameter data can be entered either on the control panel via the display and operating fi eld or via a PC keyboard or, in a more comfortable way, can be created on a PC by means of the parameter setup software PARSOFT and loaded into the control panel. Thus, a quick and effi cient transfer of the system confi guration into the control panel is guaranteed.
  • AUTO setup facilitates parameterisation when the control panel is commissioned or expanded and thus helps to save time.
  • After commissioning, the panel‘s basic functions immediately make it ready for operation. A monitored siren output and dry relay contacts for alarm and fault are available by default.
  • One Loop Interface LIF64-1 for the connection of detectors and modules in ADM loop technology is installed in the control panel by default. Depending on the parameterisation, either the Apollo/Discovery protocol or the System Sensor/200 protocol is used to achieve bi-directional data transfer.
  • The optional Fire Brigade Interface FWI2-1 serves for the connection of 2 independent transmitting devices for a direct interconnection to a designated alarm respondent (e.g., the fi re brigade) as well as for the connection of a country–specifi c fi re brigade control unit. By using the Fire Brigade Interface Additional Board FWZ2-1, a line supervision for both of the transmitting devices is accomplished.
  • The BC216-1S is able to control up to 126 detectors or modules, 128 detector zones, 128 actuations, 10 transmission devices and 99 alarming devices.
  • Customizable outputs and logical combinations of detectors and detector zones for the activation of external controls and alarming devices facilitate maximum fl exibility. Thus, no additional expenses arise for external relays, logic gates or timers. Thanks to the wide range of parameterisation possibilities, individual requirements even under the most diffi cult ambient conditions can be combined into a reasonable fi re protection strategy.
  • By integrating input and output modules on any position in the loop you can realize enablements or disablements as well as control tasks in your system without having to care for additional wires.
  • The free combination of detectors and modules into logic sectors allows for the joint operation of defi ned parts of the system. Up to 199 sectors can be controlled by the BC216-1S.
  • The use of unshielded loop cables allows for costsaving and uncomplicated installation as well as for the possibility of reusing the existing cabling.
  • The LC text display shows events with the full information such as fl oor, room identifi cation as well as date and time. This allows for quick and targeted reaction in the event of a fi re as well as for easy maintenance.
  • An event memory allows for the display of the latest 500 events at any time, including all required information. Thus, all system conditions and user operations that occurred are documented in a clearly laid out

The fl at wall mount cabinet allows for an easy mounting in virtually any place of the building. Thanks to its mo- dern, ageless design, architectural requirements and demands of the respective regulations are ideally com- bined. The compact design allows for the accommo- dation of the Loop Interface, the auxiliary modules and batteries up to 22Ah apart from the central processing board in the standard case. If a higher battery capaci- ty is needed, an auxiliary case of the same design is available.

This product complies with all relevant standards of EN 54 and is VdS-certifi ed. In addition, the product also holds several country-specifi c approvals and certifi ca- tes. LST‘s high quality level is secured by a permanent- ly monitored quality management system certifi ed by ISO 9001.

BC216-1S_DBL_LST_EN_0804.PDF • PAGE 2 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 3 of the LST BC216-1S user manual — Specifi cations
Page 3 · click to enlarge
Page 3

Permanent Connection

A variety of peripheral devices can be connected to the

fi re detection control panel BC216-1S:

  • Fire brigade key safe
  • Fire brigade control unit
  • Acoustic and optical signaling devices
  • External protocol printer
  • Remote indication unit
  • Actuations
  • Modules for remote parameterisation and remote maintenance via computer newtork, modem or GSM connection – and much more.
LST BC216-1S — Permanent Connection diagram (page 3)
Fig. 8 · Permanent Connection
LST BC216-1S — Permanent Connection diagram (page 3)
Fig. 9 · Permanent Connection

Specifi cations

Mains voltage 230VAC +10/-15%, 50Hz

Output voltage typ. 28VDC

Output peak current max. 1.8A

Connection of external devices typ. 0.8A, site-specifi c

Own current consumption at 24V typ. 115mA (incl. LIF64-1, without detectors/modules)

Ambient temperature -5°C to +50°C

Dimensions W × H × D 420 × 520 × 120 (mm)

Colour gray-white, RAL 9002

Weight without accumulator approx. 6kg

Approvals (EN 54-2, EN 54-4) VdS G201017 FT 14/147/3/99 (Austria),

Order name Fire detection control panel BC216-1S

BC216-1S_DBL_LST_EN_0804.PDF • PAGE 3 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED

Connection power 60VA

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LST BC216-1S

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LST BC216-1S

Be the first to ask — other owners or our team will answer.

Original document

LST BC216-1S manual PDF

3 pages·158 KB·Smoke Alarm·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…