EN
Linear logo
Official user manual

Linear T-90

2 pages·226 KB·Home Security System·PDF·ENDEFRITNLJA
Linear T-90
Table of Contents 80 sections STEP 6 Select switch side. Place the internal contact · jumper on the pins closest to the transmitter side on which the · (FACTORY SETTING) · ADJUSTABLE · … ShowHide
STEP 6 Select switch side. Place the internal contactp.1jumper on the pins closest to the transmitter side on which thep.1(FACTORY SETTING)p.1ADJUSTABLEp.1JUMPER TO RIGHTp.1FOR MAGNET ONp.1MAGNETp.1TWO DL2032p.1BATTERYp.1SCREWp.1DOUBLE STICK TAPEp.1OR CR2032p.1BATTERIESp.1CLAMPp.1THIS SIDEp.1SCREWS ANDp.1JUMPER TO LEFTp.1DISABLE PINSp.1INTERNALp.1CONTACTp.1ALIGNMENTp.1MARKp.1REDUCTIONp.1TALL BATTERYp.1CLAMP FORp.1LONG-LIFEp.1RINGp.1SIDE SELECTp.1ANTENNAp.1JUMPERp.1TRANSMITTERp.1TEST/TAMPERp.1EXTERNALp.1TERMINALSp.1ENTRYp.1OPTIONp.1SWITCHp.1WIREp.1SLOTp.1T-90p.1T-90 transmitter is compatible with any Linear SX formatp.1STEP 2 Remove battery protection strip. Pull the batteryp.1STEP 5 Remove mounting plates. Use a smallp.1IF USING EXTERNAL CONTACTS, SKIP TO STEP 8p.1PROTECTIONp.1STRIPp.1REMOVEp.1LIFT TAB WITHp.1SCREWDRIVERp.1SQUEEZEp.1STRIP TOp.1PULLp.1DESCRIPTIONp.1MOUNTINGp.1PLATE OFFp.1SLIDEp.1STEP 1 Remove cover. Remove the T-90 transmitterp.1cover by twisting a small screwdriver in the top slot (the fatp.1STEP 4 Pick transmitter location. Select a location forp.1Low level mounting can reduce transmission range and mayp.1subject the transmitter to damage. Mounting the transmitterp.1on metal frame doors and windows is not recommendedp.1EXTRA SWITCHp.1NEXT TO DOORp.1FOR WINDOWp.1(760) 438-7000 • FAX (760) 438-7043p.1EXTRA SWITCH FORp.1ADJACENT WINDOWp.1FORMAT!p.1SXp.1ON FRAMEp.1Installation Instructionsp.1TWISTp.1DIGITAL SECURITYp.1LIFTp.1SUPERVISEDp.1ON DOORp.1MAGNET ONp.1WINDOWp.1mounting plate. Mount the external contact or sensor asp.2
Page 1 of the Linear T-90 user manual — LIFT
Page 1 · click to enlarge
Page 1

The transmitter is powered by two self-contained type 2032 3-volt

batteries. These batteries are supplied with the transmitter and have

sufficient life for most installations. Larger, type 2450 batteries can be

used to power the transmitter longer in high traffic installations. When

the battery voltage gets low, a low battery report is sent with any status,

alarm, tamper or test report to the receiver. Use only DL2450, or

protection strip out from underneath the battery clamp. STEP 3 Identify transmitter components. Examine the

STEP 6 Select switch side. Place the internal contact

jumper on the pins closest to the transmitter side on which the

(FACTORY SETTING)

ADJUSTABLE

JUMPER TO RIGHT

FOR MAGNET ON

MAGNET

TWO DL2032

BATTERY

SCREW

DOUBLE STICK TAPE

OR CR2032

BATTERIES

CLAMP

THIS SIDE

BATTERY

CLAMP

SCREWS AND

JUMPER TO LEFT

FOR MAGNET ON

MAGNET

DISABLE PINS

THIS SIDE

transmitter to identify the component locations.

INTERNAL

CONTACT

ALIGNMENT

MAGNET

MARK

REDUCTION

TALL BATTERY

BATTERY

CLAMP FOR

LONG-LIFE

BATTERIES

RING

DOUBLE STICK TAPE

INTERNAL

CONTACT

SIDE SELECT

ANTENNA

JUMPER

TRANSMITTER

SCREWS AND

ALIGNMENT

MAGNET

MARK

CR2032 batteries.

TEST/TAMPER

EXTERNAL

TERMINALS

ENTRY

magnet will be.

TRANSMITTER

OPTION

SWITCH

SWITCH

CONTACT

WIRE

SLOT

T-90

The T-90 is a supervised, digitally-coded radio transmitter designed

for applications such as door/window security. The T-90 is supervised

for alarms and restorals, low battery, status, tamper, and test. The

T-90 transmitter is compatible with any Linear SX format

Coding switches are not required or used in the T-90. Each transmitter

is pre-coded at the factory to a unique code. With the SX format, there

The T-90 can be triggered with the built-in internal magnetic contacts,

with various types of external contacts, or both. When using one of

the internal contacts and the external input, both sensors must be

secured for a restore transmission, faulting either sensor will cause

an alarm transmission. External inputs can be either normally open

Switch selected options are included for glass break sensors, built-in

STEP 2 Remove battery protection strip. Pull the battery

STEP 5 Remove mounting plates. Use a small

screwdriver to remove the transmitter’s mounting plate.

Squeeze the magnet’s tabs to remove its mounting plate.

IF USING EXTERNAL CONTACTS, SKIP TO STEP 8

PROTECTION

BATTERY

pulse stretcher, battery saver, and external input type.

STRIP

REMOVE

are more than sixteen million codes possible.

LIFT TAB WITH

SCREWDRIVER

SQUEEZE

supervised security receiver.

STRIP TO

REMOVE

PULL

or normally closed.

DESCRIPTION

MOUNTING

PLATE OFF

SLIDE

STEP 1 Remove cover. Remove the T-90 transmitter

cover by twisting a small screwdriver in the top slot (the fat

STEP 4 Pick transmitter location. Select a location for

the transmitter. Avoid mounting the transmitter near the floor.

Low level mounting can reduce transmission range and may

subject the transmitter to damage. Mounting the transmitter

on metal frame doors and windows is not recommended

EXTRA SWITCH

NEXT TO DOOR

FOR WINDOW

USA & Canada (800) 421-1587 & (800) 392-0123

(760) 438-7000 • FAX (760) 438-7043

because the radio range will be reduced.

Toll Free FAX (800) 468-1340

EXTRA SWITCH FOR

ADJACENT WINDOW

FORMAT!

TRANSMITTER

SX

ON FRAME

Installation Instructions

TWIST

DIGITAL SECURITY

TRANSMITTER

end of the transmitter).

LIFT

SUPERVISED

T-90

MAGNET

ON DOOR

TRANSMITTER

ON FRAME

MAGNET ON

WINDOW

Page 2 of the Linear T-90 user manual — Close the door or window
Page 2 · click to enlarge
Page 2

Copyright © 2006 Linear LLC 207138 F

jumper and place it on the internal contact disable pins. STEP 9 Install contact or sensor and transmitter

mounting plate. Mount the external contact or sensor as

described in its instructions. For recessed wiring, drill an

STEP 12 Close transmitter case. Close the case by

locking the top together first, then snap the bottom together.

This Linear product is warranted against defects in material and workmanship for twelve (12) months. The

Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who

buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product

to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if

any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising

out of or in connection with use or performance of this product or other indirect damages with respect

to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied

warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until

Warranty Expiration Date as labeled on the product. This Linear LLC Warranty is in lieu of all other warranties

All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact

Linear radio controls provide a reliable communications link and fill an important need in portable wireless

Linear radio controls provide a reliable communications link and fill an important need in portable wireless

1 For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.

1 A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.

1 Changes or modifications to the device may void FCC compliance. 1 Infrequently used radio links should be tested regularly to protect against undetected interference or fault. 1 A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.

*** FOR EXTERNAL CONTACTS ONLY *** *** FOR EXTERNAL CONTACTS ONLY ***

Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

signalling. However, there are some limitations which must be observed.

signalling. However, there are some limitations which must be observed.

LINEAR LIMITED WARRANTY

access hole for the wire.

LOCK TOP

TOGETHER

THEN SNAP

CASE SHUT

IMPORTANT !!!

express or implied.

STEP 8 Change contact jumper. Remove the side select

STEP 11 Complete transmitter setup. Set option

switch #2 to enable or disable the 2-minute wait timer. Setting

switch #2 ON enables 2-minute wait timer (after triggering, unit

waits 2 minutes before re-triggering). Switch #3 must be off

ONLY ONCE EVERY TWO MINUTES

OPTIONAL LONG LIFE BATTERIES To increase the

battery life of the unit in high traffic uses, replace the two type

CR2032 with two DL2450 batteries. Exchange the battery

clamp for the taller one provided, and remove the battery

(MAT SWITCHES, PIR'S, ETC.)

SET SWITCH #2 ON FOR

HIGH ACTIVITY DEVICES

TRANSMITTER CAN ACTIVATE

1 2 3 4

OPEN

MOVE JUMPER FROM HERE

(3-PIN SIDE SELECT POSTS)

(2-PIN INTERNAL CONTACT

BATTERIES

when only using the internal contacts.

DL2450

DISABLE POSTS)

SCREW

TALL

CLAMP

OPEN = OFF

CLAMP DL2032/CR2032

SLIDE CLAMP

THROUGH SLOT

TO HERE

BATTERIES

SET SWITCH #2 OFF (OPEN) FOR

LOW ACTIVITY DEVICES (DOOR

TRANSMITTER WILL ACTIVATE

SWITCHES, WATER SENSORS,

EACH TIME IT IS TRIGGERED

WINDOW SCREENS, ETC.)

1 2 3 4

OPEN

reduction ring.

REDUCTION

SHORT

RING

STEP 7 Attach mounting plates. Use the screws or

double-stick tape provided to affix the mounting plates. Be sure

the magnet will be adjacent to the magnet alignment marks.

Mount the magnet no further than 1/2 inch from the transmitter.

STEP 10 Connect to terminals and set option switch.

Connect two wires from the external sensor to the external

contact terminals. Set the option switches for the type of sensor.

STEP 13 Program transmitter into receiver and test.

Follow the receiver’s instructions to set it in a program or learn

mode. Press the bottom of the transmitter case to send a test

signal. Verify that the signal was received and that the transmitter

*** FOR EXTERNAL CONTACTS ONLY ***

FOR INTERNAL CONTACTS, SKIP TO STEP 11

Snap transmitter and magnet onto mounting plates.

ALARM & RESTORE

OPEN & CLOSE

DOOR FOR

SEND TEST

PRESS TO

SIGNAL

was properly entered into

the receiver’s memory.

Set the receiver into a

monitor or chime mode.

Open the door or window

monitored by the

transmitter and verify

that the receiver accepts

the alarm transmission.

Close the door or window

and verify that the restore

signal was accepted.

Ask about the Linear T-90

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear T-90

Be the first to ask — other owners or our team will answer.

Original document

Linear T-90 manual PDF

2 pages·226 KB·Home Security System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…