AL-1 ALERT RESET SERVICE POWER Pull Cord Alert Link Installation Instructions (760) 438-7000 • FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com 3. COMPONENT LOCATIONS1. PRODUCT DESCRIPTION2. OPEN THE CASE
The Model AL-1 is a wireless personal alert receiver designed for use with existing nurse call annunciation systems. In a typical installation, the receiver is used in the place of, or in conjunction with, a standard pull cord to activate a corridor light, bed light, room light, and any audible devices to indicate the need for assistance. Up to 32 wireless transmitters can be programmed to activate each receiver. Three indicators on the front of the receiver display the system status. The green POWER indicator lights when power for the receiver is present. The yellow SERVICE indicator lights if a transmitter has sent a low battery signal. The red ALERT indicator lights when a transmitter has been triggered, showing that the receiver’s outputs have been activated. Pressing the RESET button on the top of the receiver for less than two seconds will reset any transmitter low battery indications. Pressing the RESET button for more than three seconds will clear the ALERT indication and reset the relay outputs if in the latched mode. The receiver contains four normally open 1-amp relay contacts that close when activated. One relay provides an isolated output. The three other relays are isolated when open and have a common return. The receiver relays can operate in “normal” or “failsafe” mode. In normal mode, the relays will energize when the receiver is triggered. In failsafe mode, the relays are energized continuously until the receiver is triggered. Failsafe mode supervises the system by causing the outputs to activate if power is removed from the receiver. Both modes provide normally open outputs. Power for the receiver is supplied by a plug-in transformer. The receiver can be mounted directly to a wall or to a single-gang electrical box with the hardware supplied. 4. SET THE MODESQUEEZE THE CASE SIDES NEAR THE TABS AND TILT UPWARD 5. INSTALL THE MOUNTING PLATE
RESET BUTTON ALERT LIGHT PRESS FOR 1 SECOND TO LATCH JUMPER LIGHTS RED WHEN THE RESET SERVICE INDICATOR; LATCHES ALERT OUTPUTS OUTPUTS ARE ACTIVATED PRESS AND HOLD FOR 3 SECONDS JUMPER OFF = MOMENTARY TO RESET OUTPUTS MODE JUMPER JUMPER ON = LATCH SELECTS NORMAL OR SERVICE LIGHT FAILSAFE MODE LIGHTS YELLOW WHEN JUMPER OFF = NORMAL A TRANSMITTER HAS ALERT RESET JUMPER ON = FAILSAFE SENT A LOW BATTERY S POER WV EIC RE SIGNAL STATUS LIGHT FLASHES WHEN POWER LIGHT RADIO SIGNALS LIGHTS GREEN WHEN ARE RECEIVED; THE RECEIVER HAS LIGHTS WHEN POWER READY TO LEARN OR ERASING TRANSMITTERS; BLINKS TO COUNT FRONT THE NUMBER OF TRANSMITTERS LEARN BUTTON PRESS TO ENTER LEARN MODE FOR INSIDE ENTERING TRANSMITTERS; PRESS AND HOLD FOR 5 SECONDS TO MODE SWITCHES DISPLAY THE NUMBER OF TRANSMITTERS; SETS THE OUTPUT MODE MUST BE SET TO MATCH CONTINUE TO HOLD FOR 5 SECONDS AFTER THE MODE JUMPER THE TRANSMITTER COUNT TO ERASE ALL TRANSMITTERS 6. CONNECT THE OUTPUTSNORMAL MODE RELAYS ACTIVATE DURING ALERT MODE JUMPER OFF OR ON ONE PIN - AND - BOTH MODE SWITCHES TO NORMAL IMPORTANT! THE MODE JUMPER MUST MATCH THE MODE SWITCH SETTINGS FAILSAFE MODE RELAYS ACTIVATE DURING ALERT AND DURING POWER FALURE MODE JUMPER ON BOTH PINS - AND - BOTH MODE SWITCHES TO FAILSAFE 7. CONNECT THE TRANSFORMERATTACH THE MOUNTING PLATE DIRECTLY TO THE WALL WITH WOOD SCREWS AND ANCHORS OR USE THE MACHINE SCREWS TO ATTACH THE MOUNTING PLATE TO A SINGLE-GANG ELECTRICAL BOX WOOD SCREWS MACHINE SCREWS 8. TRANSMITTER SETUP
CONNECT THE OUTPUTS TO THE LOCAL CALL ANNUNCIATION AL-1 OUTPUT WIRE COLORS SYSTEM CONNECTIONS WILL VARY SERVICE OUTPUT DEPENDING ON THE MAXIMUM LOAD - 28 V @ 1 A INSTALLATION WIRE NUTS ARE SUPPLIED ORANGE BROWN FOR MAKING CONNECTIONS SERVICE RELAY ALERT OUTPUTS LATCHES WHEN ONE OR MORE GRAY VIOLET STORED TRANSMITTERS INDICATE A LOW BATTERY A MOMENTARY OR LATCHED WHITE YELLOW ALERT RELAY OUTPUT IS SELECTED BY THE "LATCH" JUMPER ON PINS = LATCH WHITE GREEN OFF PINS - MOMENTARY CAUTION MAXIMUM CURRENT BLUE FOR EACH RELAY CONTACT IS 1 AMP 9. CLOSE AND SECURE THE CASECONNECT THE RED AND BLACK POWER INPUT WIRES TO THE TRANSFORMER WIRES OR TO THE SYSTEM'S AUXILIARY POWER 12-16 VOLT AC/DC POWER RED BLACK CAUTION POWER INPUT MUST NOT EXCEED 16 VOLTS PLUG THE TRANSFORMER INTO AN UN-SWITCHED 120 VAC OUTLET 10. SYSTEM TEST & OPERATIONLEARN BUTTON ACTIVATING TRANSMITTER TO ADD A TRANSMITTER PRESS AND RELEASE THE LEARN BUTTON, STATUS INDICATOR WILL LIGHT (IF NOT, THE MEMORY IS ALREADY FULL) STATUS LIGHT ACTIVATE A TRANSMITTER, THE STATUS INDICATOR WILL FLASH WHEN THE TRANSMITTER IS ACCEPTED (UP TO 32 TRANSMITTERS ALLOWED) TO CHECK THE TOTAL NUMBER OF TRANSMITTERS IN MEMORY PRESS AND HOLD THE LEARN BUTTON FOR ABOUT 5 SECONDS, THE STATUS INDICATOR WILL BLINK ONCE FOR EACH TRANSMITTER IN MEMORY TO ERASE ALL TRANSMITTERS CONTINUE TO HOLD THE LEARN BUTTON FOR ABOUT 10 SECONDS AFTER THE TRANSMITTER COUNT,THE STATUS INDICATOR WILL BLINK ONCE WHEN THE RECEIVER MEMORY IS ERASED LINEAR LIMITED WARRANTY
TAB FITS IN SLOT ALIGN TOP OF CASE INTO THE SLOT SQUEEZE THE CASE SIDES AND SNAP THE COVER ONTO THE MOUNTING PLATE SECURE THE CASE BY INSERTING THE TWO SHORT SCREWS INTO THE BOTTOM TABSACTIVATE EACH TRANSMITTER IF IN THE LATCH MODE, FROM VARIOUS LOCATIONS PRESS THE RESET BUTTON FOR AT LEAST 3 SECONDS TO RESET THE OUTPUTS AND TURN OFF THE ALERT INDICATOR MOMENTARILY PRESS THE RESET BUTTON TO TURN OFF THE SERVICE INDICATOR (TRANSMITTER LOW BATTERY) ALERT RESET SERVICE POWER POWER INDICATOR SHOULD BE LIT ALERT INDICATOR SHOULD LIGHT WHEN THE TRANSMITTER IS ACTIVATEDThis Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear Corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Service at 1-800-421-1587 for an RPA# and other important details. IMPORTANT !!! Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signalling. However, there are some limitations which must be observed. • For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range. • A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. • Changes or modifi cations to the device may void FCC compliance. • Infrequently used radio links should be tested regularly to protect against undetected interference or fault. • A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users. Copyright © 2002 Linear Corporation 218387 B