(760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123
Free FAX No. (800) 468-1340




Programming Access To make life easier for installers familiar with Linear systems and other manufacturers of access control systems, two programming methods are available. The programming position numbers (or function codes) that match those of other equipment help the installer to quickly make changes by typing on different keys they have used to use before.

Choice of automatic programming method Programming position numbers (or function codes) change according to the programming method used. See the table on page 6 for numbers used with each method. The keys used to enter programming from the unit's digital keyboard select the programming method that will be used during the current programming session. The programming input by pressing the keys at once & selects the standard programming method (Linear access style). Details of each programming step by standard method are given on pages 8 to 14. The programming input by pressing the keys at once and selecting the Other Programming Method (other style of access by other manufacturers). Details of each programming step by the Other Method are given on pages 15 to 22. Programming from the Digital Keyboard (Standard Method) The system can be programmed using the digital keyboard on the face of the AE-100 housing. The posting indicates the programming information.


ALPHANUMERIC KEYBOARD INPUT (WHEN PROGRAMMING STEPS REQUIRE TEXT ENTRY)
a b c d e f g h i
1. Press & then release the keys at the same time 2. The publication indicates [PASSWORD:] 3. Enter the main password (the factory code is 123456). 4. Press . 5. If the password is correct, posting indicates [ENTER FUNCTION:]. 6. Programming commands can then be entered on the digital keyboard. See the following sections of the manual for details of this step. See also illustrations for alphanumeric characters on the digital keyboard. Voice prompts on the digital keyboard If the program is programmed using a digital keyboard, each of the programming steps consists in entering the program data. With the standard programming method, the system issues sound beeps to indicate whether or not input is correct.
Press the back or erase key
After a correct entry, two short beeps are heard. After incorrect typing, a long beep is heard. When the programming step is completed correctly, three short beeps are heard. Re-entering an order after error If you have an incorrect input, or if it is pressed by mistake on a key during programming, press to reset the digital keyboard and start over step operations.
programming after five minutes of inactivity.
• • •

Phone Programming Most system commands can be programmed on a TouchToneTM phone. The keyboard of the phone behaves like a digital keypad for AE-100s unit. Both methods of programming can be used with a telephone. Telephone connection
1. CALL SYSTEM 2. THE SYSTEM RESPONDS TO THE THIRD RINGING 3. THE SYSTEM EMITS SOUNDS INDICATING CURRENT STATE: > A SHORT BEEP ALL RELAYS ARE OPERATED > TWO SHORT BEPS ALL RELAY IS DISABLED > ONE LONG BEEP SOME RELAYS OPEN AND OTHERS CLOSED 4. ENTER THE UNIT NUMBER (1 TO 4) AND PRESS # FOR SINGLE UNIT INSTALLATIONS, PRESS 1# 5. ENTER THE MAIN PASSWORD (DEFAULT PASSWORD: 123456) 6. TO USE THE STANDARD PROGRAMMING METHOD, PRESS [#] TO USE OTHER PROGRAMMING METHOD AND PRESS [*] 7. START PROGRAMMING, ENTER THE STEP NUMBER FOLLOWED BY [#]
A short beep sounds if all the access relays are activated (all doors open). Two short beeps sound if all access relays are disabled (all doors closed). A long beep sounds if there is a combination of activated and deactivated access relays (some doors are open, others closed). 4. Enter the unit number (1 to 4) that you want to connect to and then tap on With a single unit installation, enter the default number 1 assigned to the unit. ✦ NOTES: Connect to main unit No. 1 d
install several units to program the main memory. The main memory can then be copied to each of the other units. 5. Enter the main unit password (the factory programmed code is 123456).
press To program using the Other Programming Method,

If the password is correct, then the system issues two short beeps. 7. You can then enter the programming commands from your phone keyboard. To program the system, see the following pages of the manual.
The steps of the standard programming are shown on pages 8-14. The steps in the Other Programming Method are shown on pages 15 to 22. Voice calls from the phone When programming by telephone, each step of the program consists in entering programming data using the phone keyboard. The system issues beeps via the phone to indicate whether or not entries are correct. Voice prompts that provide feedback during programming are different in each of the programming methods. These differences are shown in the table on the right. Re-entering an order after error If you have an incorrect input, or if the key is pressed by mistake during programming, press and start over. Programming mode output Do not forget to leave the programming mode after completing it.

TO EXIT THE PROGRAMMING MODE STANDARD PROGRAMMING METHOD
programming mode after five minutes of inactivity. To exit the programming mode when using standard method, press: To leave the programming way when using Other Programming Method, tap:



Pre-confied unit numbers The company that installed your input system has already programmed this system. If it is a multi-unit installation, subunit numbers have already been given in the subunits and the main unit has also been programmed to recognize these numbers.

Resident data programming Up to 125 resident names and telephone numbers can be given. Each resident is assigned one Directory number. The directory number is the number that visitors must enter in order to call the resident. Visitors can also call a resident whose name is displayed by pressing the button . Use the programming fiche provided to organize resident data before entering them into the system. For each of the following steps, enter the main password and enter in the programming mode (if unit is not already there). Exit the programming mode when all programming is complete.
Change in length of directory numbers The factory confi gation of the directory numbers assigns to these three digits. This can be changed into two or three digits.
NPP 02 02#LENGTH#
FACTORY CONFIGURATION: 3 DIGITS
Entering a resident's data in the directory
21#REP#NAME#TELEPHONE#CODE#CODE
REP = RESIDENT'S DIRECTORY NUMBER NAME = RESIDENT NAME (UP TO 16 CHARACTERS) PHONE = RESIDENT TELEPHONE NUMBER (UPTO 14 DIGITS) CODE = RESIDENT ACCESS CODE (4 DIGITS) CODE = NEW ENTRY OF THE CHECK ACCESS CODE
keys, , or hold them down to record 1-4 breaks of two seconds. Hold the key down for about two seconds. NOTES: Each pause entered counts as one of the 14 digits allowed for telephone number. 7. Press 8. Enter a access code single four-digit for this resident. 9. Press 10. Enter the access code Single four-digit check. 11. Press
Changes to existing resident data in the directory Once an entry has been entered into the register, it can be changed to change the name, telephone number or access code of the resident.
NPP 22
✦ NOTES: This step cannot be done remotely by telephone. 1. Press 2. Enter the Directory number the resident. 3. Press NOTES: To change the name using capital letters,
REP = RESIDENT'S DIRECTORY NUMBER NAME = RESIDENT NAME (UP TO 16 CHARACTERS) PHONE NUMBER = RESIDENT TELEPHONE NUMBER (UPTO 14 DIGITS) CODE = RESIDENT ACCESS CODE (4 DIGITS)
Press before entering the name. 4. Change the name the resident has a good deal (up to 16 characters), and apppuy on the key, or to keep the same name, press . 5. Change the telephone number The resident (up to 14 digits, see above how to enter breaks and press , or to keep the same phone number, tap . 6. Change the access code If you want to keep the same access code, simply press . Clearing an existing entry in the directory The entries of the directory can be deleted individually (to delete all entries from the directory, see the programming step 92).
NPP 23
23#REP#REP #REP= RESIDENT'S DIRECTORY NUMBER REP= RESIDENT RE-ENTERED REGISTER NUMBER FOR VERIFICATION

Programming an independent access code One independent access code is a number entered by the digital keyboard of unit AE-100 to request entry. Up to 125 independent four-digit access codes can be programmed.
reduces by one unit the number of possible entries in the directory. Use the programming fiche provided to organize independent access codes before entering them into the system. For each of the following steps, enter the main password and enter in the programming mode (if unit is not already there). Exit the programming mode when it is complete.
Seizure of an independent access code Independent access codes must be entered separately.
CODE = NEW INDEPENDENT ACCESS CODE CODE = RE-ENTERING THE INDEPENDENT ACCESS CODE FOR VERIFICATION
Clearing an Independent Access Code Independent access codes can be entered separately. (to delete all independent access codes, see Programming Step 93).
NPP 33 33#CODE#CODE#
CODE = INDEPENDENT ACCESS CODE TO BE DELETED CODE = NEW ENTRY OF THE INDEPENDENT ACCESS CODE FOR VERIFICATION

System Options Factory configurations will be appropriate in most cases. To customize the system, access the programming mode by phone or via the digital keyboard. Use the programming fiche provided to record all changes made to system options before entering them into the system. For each of the following steps, enter the main password and enter in the programming mode (if unit is not already there). Exit the programming mode when it is complete.
System Display Language The system's default language is English. Three other languages may be chosen as the user language and for programming features.
NPP 38 38#LANG#
LANG = SYSTEM DISPLAY LANGUAGE 1 = ENGLISH 2 = SPANISH 3 = FRENCH 4 = PORTUGUESE
language at once. 1. Press 2. Choose a language: Enter 1 for English Enter 2 for Spanish Enter 3 for French Enter 4 for Portuguese 3. Press Count before locking the digital keyboard The system counts the number of invalid access codes entered by the numeric keypad. If the number of input tests exceeds the fi xed number for locking, the digital keyboard is locked for 90 seconds. The factory confi gation for this number of tests is three. The possible value is one to nine.
NPP 51 51#COUNTING#
COUNT = NUMBER (1 TO 9) OF INCORRECT INPUT TESTS THAT CAUSE THE LOCK FOR 90 SECONDS
The time to actuate the access relay The factory confi gation causes the relay to operate for four seconds. The operating time can be adjusted between 4 and 99 seconds to suit different types of input control devices.
NPP 52 52#SECONDS#
FACTORY CONFIGURATION: 4 SECONDS

System Options (continued) Text of the host message displayed L'Unité AE-100 has a visitor reception message alternating with instructions to find and call a resident. The home message can be customized according to the installation.

Phone. 1. Press ✦ NOTES: To enter only letters of printing, press
LINE 1 = UP TO 16 CHARACTERS LINE 2 = UPTO 16 CHARACTERS
first on: before entering the text.
first on: before entering the text. 4. Type the new text for the lower line of display (up to 16 characters). 5. Pressing Automatic Telephone Response The factory confi gation allows the system to detect a ringtone on the telephone line and respond to the call.
NPP 61 61#RESPONSE#
be disabled, but in this case remote programming functions, resident remote control and residents recall are also deactivated. 1. Press 2. Choose the automatic phone response option: Enter 0 to DISACTAIN the autophone answer. Enter 1 for ACTIVER the automatic phone response. 3. Press Clicking the Keys heard in the speaker The factory config allows you to hear the key clicks in the loudspeaker whenever it is pressed on a button of the digital keyboard. This feature can be disabled.
RESPONSE = 0 TO DISABLE THE ANSWER CALL RESPONSE = 1 TO ACTIVATE THE REPLY TO THE CALL
CLICKING THE KEYS HEARD IN THE SPEAKER
NPP 62 62#CLICK #
CLICK = 0 TO DISABLE THE RATCHETING OF KEYS CLICK = 1 TO ACTIVATE THE RATTLING OF KEYS
Tonality heard in the speaker when operating the access relay The factory confederation causes a tone to be heard in a loudspeaker for two seconds when running the access relay. It is possible to disable this tone.
NPP 63 63#TONALITY#
TONE = 0 TO DISABLE THE TONE OF THE SPEAKER TONES = 1 TO ACTIVATE THE VOICE OF THE LOUDSPEAKER

System Options (continued) Maximum time for conversation with visitors Visitors can speak on the phone to the resident until he or she grants or refuses entry into the residence. If the resident responds to a visitor's request by pressing the phone key, the system hangs up and releases the telephone line. If for some reason the resident does not press or hang up on the phone key, then the system will cut the line to the visitor after 60 seconds. Ten seconds and then five seconds before hanging up, a tone is heard on the phone line to remind the resident of the imminent cut. The resident can extend the conversation by pressing the # button on his/her phone. The duration before disconnection can be set between 10 and 180 seconds.
MAXIMUM DURATION OF CONVERSATION WITH VISITORS
64#DURING
DURATION = TIME TO AUTOMATIC CONVERSATION SHUTDOWN (010-180 SECONDS)
1. Press 2. Enter the conversation duration in seconds (010 to 180). 3. Press the Relay Control by the Resident The factory confi gation allows the resident to activate the access relay by pressing key 9 of his phone when he receives a call from unit AE-100. This function can be disabled. When this function is disabled, the input can only be granted by using the resident's access code and independent access codes entered on the unit's digital keyboard.
NPP 77 77#COMMAND#
COMMAND = 0 TO DISABLE THE ORDER BY RESIDENT COMMAND = 1 TO ACTIVATE THE ORDER FROM RESIDENT
1. Press 2. Choose the option of commanding the access relay by the resident: Enter 0 to DISACTIVER the control of the access relay by the residents. Enter 1 for ACTIVER the control of the access relay by the resident. 3. Press Reminder by Resident The callback function by the resident allows AE-100 to answer the phone and switch into speaker mode if the telephone is dialed within 60 seconds of last use of the AE 100 unit. This function gives residents who have missed a visitor's recent call the opportunity to recall the latter. This function can only be used on single unit installations. The factory confi gation disables the recall function by the resident. But this function can be activated.
NPP 95 95#RECALL#
REMINDER BY THE RESIDENT
REMINDER = 0 TO DISABLE THE RECALL BY RESIDENT RECALLS = 1 TO ACTIVATE THE CALLBACK BY RESIDENT
be enabled, the automatic telephone response function NPP #61 must also be activated.

System utility controls Several utilities commands are available for the system. These commands can be used to copy data from other units of a multi-unit system, erase memory, provide information about the system and control relays. For each of these steps, enter the main password and enter in the programming mode (if unit is not already there). Exit the programming mode when it is complete. Copying data only from the main unit to subunits To synchronize programming in multi-unit installations, directory numbers and access codes can be copied from the primary unit to selected subunit.
NPP 30
30#SUBUNITS#5#
The first is for installation to several units. ✦ NOTES: This utility command can only work from
SUBUNITS = NUMBER OF EACH SUBUNIT (2 TO 4) TO WHICH ACCESS DATA IS COPIED IN A MULTI-UNIT SYSTEM
Main unit.
access data which existed in the selected subunits. 1. Press 2. Enter the unit number(s) of all subunits that must receive access data. Examples:
To copy to Unit Two, enter only To copy into Unit Three, type Only To copy towards Units Two and Three, enter To copy back to Units Two, Three and Four, enter 3. To execute the command, enter or input to exit (any other input will cancel the order).
Copying all data from the main unit to subunits To synchronize programming in multi-unit facilities, all system data can be copied from the primary unit to selected subunit. This includes directory numbers, independent access codes and all system options except the subunit number).
NPP 34
34#SUBUNITS#5#
SUBUNITS = NUMBER OF EACH SUBUNIT (2 TO 4) TO WHICH THE DATA SET IS COPIED IN A MULTI-UNIT SYSTEM
The first is for installation to several units. ✦ NOTES: This utility command can only work from
data which existed in the selected subunits. 1. Press 2. Enter the unit number(s) of all subunits that must receive all data. Examples:
To copy to Unit Two, enter only To copy into Unit Three, type Only To copy towards Units Two and Three, enter To copy back to Units Two, Three and Four, enter 3. To execute the command, enter or input to exit (any other input will cancel the order).

System utility controls (cont'd) Temporary locking of the access relay For maintenance or testing, while the unit is in programming mode it is possible to manually lock the access relay from the digital keyboard for a few hours.
NPP 80 80#HOURS#HRS = TEMPORARY LOCKING OF THE ACCESS RELAY IN HOURS (01 TO 98)
temporary locking provided by the NPP 80. 1. Press Unlocking the access relay For maintenance or testing, and while the unit is in the programming mode it is possible to unlock the access relay when manually locked from the digital keyboard (temporarily or unsurely).
NPP 83 83#
Clearing all entries in the directory This utility command permanently erases any resident's directory numbers, names, phone numbers and access codes.
Phone. 1. Press 2. Press again to check cation. Clearing all Independent Access Codes This utility command permanently erases any independent access codes.
NPP 93 93#93#
Phone. 1. Press 2. Press again to check cation.

Section on Alternative Programming Method To make life easier for installers familiar with Linear and other manufacturers' access control systems, two programming methods are available. Function codes adapted to other equipment help the installer quickly make programming changes using keyboard keys that they already know.

Selection of the Other Programming Method The program position numbers (or function codes) change according to the programming method used. See the table on page 6 for numbers used by each of the programming methods. The keys used to enter programming from the unit's digital keyboard select the programming method used for the current programming session. Entering the programming mode by pressing at the same time on keys & selects the Other Programming Method (other access style used by other manufacturers). Details of each of the programming stages using the Other Method are shown on pages 15 to 22. Voice Invites with the Other Method Voice prompts that provide feedback during programming by the unit's digital keyboard or on the phone are different with the Other Programming Method. These differences are shown in the table on the right.

AFTER INCORRECT ENTRY TWO LONG BEEPS A LONG BEIP
AFTER CORRECT ENTRY OF AN INTERMEDIATE STEP A SHORT BEEP TWO SHORT BEPS
AFTER CORRECT ENTRY OF A COMPLETE COMMAND TWO SHORT BEEPS THREE SHORT BEPS
OUTPUT PROGRAMMING MODE THREE SHORT BEEPS NO BEEP
Alphanumeric input into the Other Method When using the digital keyboard for alphanumeric data input in the Other Programming Method, each key captures the data differently than that of the standard interface mode. See the illustration of the digital keyboard on the right.

1. Press & and then release the keys. 2. The publication indicates [MAIN CODE:] 3. Enter the main code (the factory confi gation is 123456). 4. The display generates asterisks as one enters the code. 5. If the main code is incorrect, the system emits two long beeps and returns to normal operating mode. 6. If the password is correct, posting indicates [CHOOSE FUNCTION:] 7. The commands can then be entered on the digital keyboard. See the following pages of the manual for details on steps in the Other Programming Method. Re-entering an order after error If you are entering an incorrect input, or if you press a wrong key during programming, tap to reset the keyboard and start over the program step.
ALPHANUMERIC INPUT BY KEYBOARD FOR THE INTERFACE OF THE OTHER PROGRAMMING METHOD (WHEN PROGRAMMING STEPS REQUIRE TEXT ENTRY)
Q Z - , . ' * q z 0 1 2 3 4 5 6 7 8 9
A B C a b c D E F d e f
programming after five minutes of inactivity.

References to the Other Programming Method See the following pages for further programming methods. For each of the following steps, enter the main password and enter in the programming mode (if unit is not already there). Exit the programming mode when it is finished.
FUNCTION CODE LOCAL PROGRAMMING BY TELEPHONE 01 DATA PROGRAMMING OF A NEW RESIDENT
Step 1 Enter function code 01 and press
#, a short beep sounds.
(two or three digits) and press #, a short beep sounds. (If you hear two long beeps, it's because the directory number already exists, go back to I-Step 1.)
Step 2 Enter the Directory number Two or three
Four different fields must be programmed: directory number, name, telephone number and access code.
Directory number: A unique two or three digit identification number is assigned to each resident.
Step 3
Step 3 Enter the name of the resident (up to 16
If the directory number has already been used, posting indicates:
characters) and press # after each character, then again on # after the last character, a short beep sounds.
Name: up to 16 characters.
Step 4 Enter the telephone number (up to
Return to Step 2.
Access code: four-digit code assigned to the resident for entry using digital keyboard
14 digits), press # after each number, then again on # after the last issue, a short beep sounds.
If the memory is full, posting indicates:
Step 5 Enter access code, then press #,
Two short beeps are ringing.
Return to Step 2.
Step 3 Enter name the resident (up to 16 characters),
Press # after each character, then again on # after the last character
Step 4 Enter the telephone number of the resident
(up to 14 digits), press # after each number, then again on # after the last number. Press the 1, 2, 3 or 4 keys and hold them down for about two seconds to record 1-4 breaks of 2 seconds. NOTES: Each pause entered counts as one of the 14 digits allowed for telephone number.
Step 5 Enter the access code four digits,
Step 6 Press #.
numbers

FUNCTION CODE LOCAL PROGRAMMING BY PHONE 02 CHANGE DATA FROM
Step 2 Enter the new Directory number Two or three
figures.
Select a directory number to be modified (you need the resident's register number in order to change it).
The name the current resident is:
Step 3 To keep this name, press # and move to Step 5. Step 4 To change the name, press and then grab a
new name (up to 16 characters), press # after each character, then again on # after the last character:
Step 5 To keep this phone number, press #
and proceed to step 7.
Step 6 To change the telephone number, press
then enter a new phone number (up to 14 digits), press # after each number, and again tap # after the last number. Press the 1, 2, 3 or 4 keys and hold them down for about two seconds to record 1-4 breaks of 2 seconds. NOTES: Each pause entered counts as one of the 14 digits allowed for telephone number.
Step 7 To keep the access code, press #. Step 8 To change the access codeenter a new code
d
Step 1 Enter function code 03 and press
#, a short beep sounds.
Step 2 Enter the directory number (two or
Step 2 Enter the Directory number Two or three digits
three digits) to erase and press #, two short beeps sound. (If a long beep followed by two short beeps is heard, the directory number did not exist, return to Step 1.)
to erase, then press #:
DIRECTORY This erases a single entry in the directory. This command releases the memory occupied by an unused directory entry.
If the directory number does not exist, posting indicates an error, return to Step #1.
Step 2 Enter the number and press #.
DIRECTORY This erases all entries in the directory. This command erases all directory numbers, names, phone numbers and access codes related to the directory.
Step 3 Enter 5 for cation check, then press # (or press
on

FUNCTION CODE LOCAL PROGRAMMING BY PHONE 05 MANUAL CONTROL OF THE ACCESS RELAY
Step 1 Enter function code 05 and press #, a short beep sounds.
" "
Step 2 Enter the number of hours from 01 to 98, to activate the access relay and then press #. - OU - Enter the number 99 to activate the unsatisfied access relay and then press #. - OU - Enter the number 00 to disable the access relay, then press #. Two long beeps and two short beep sounds.
Step 2 Enter the number of hours from 01 to 98 during which
the access relay will be activated, then press #. - OU - Enter the number 99 to activate the unsatisfied access relay and then press #. - OU - Enter the number 00 to disable the access relay, then press #. - OU - Enter
This command can be used to lock the access relay unsuspected or temporarily, and to unlock the access relay.
Step 2 The display indicates the current value. Type 2 or 3, then press #.
DIRECTORY Choose two or three digits for the length of the directory number (the default factory config is three digits). NOTES: In multi-unit installations, if sub-units are updated with access data containing directory numbers that have more digits than those with which the unit is confided, then the number of digit(s) for the sub-group's directory numbers will be automatically adjusted.
- OU - Enter
10 HOME TEXT
# $
Step 2 Enter the new home message. There is
The AE-100 poster generates a message of welcome to visitors alternating with instructions for finding and calling a resident. The home message can be customized according to the installation.
32 characters to do this. The display progresses until the beginning of the lower line after the 16th character entered on the upper line. Type # after each new character, type ## after the last character.
30 COPIES OF DATA
Step 1 Enter function code 30 and press
#, a short beep sounds.
Step 2 Enter the numbers of all sub-
Step 2 Enter the unit numbers (2, 3 and 4) of all
Units (2, 3 and 4) to which the data must be copied, then press #, a short beep sounds.
subunits to copy the data to them, then press #.
To synchronize programming in the multiunit facilities, it is possible to copy directory entries and access codes independent of the main unit to selected subunits.
Step 3 Enter 5 for verification, then press
#, two short beeps are ringing. (Any entry other than 5# cancels the order.)
Step 3 Enter 5 for the cation check, then press #.
- OU -
To allow network communications in multi-unit systems, when running this remote over the phone, the system disconnects your call after step 3 and then copies data from the main unit to sub-units.
Enter
In order for this control to work, the system must be previously confided for installation with several units.

LOCAL PROGRAMMING FUNCTION CODE BY TELEPHONE 31 ACCESS CODES ENTERED
Step 1 Enter function code 31 and press #, a short beep sounds.
Step 2 Enter the new independent four-digit access code, press #, a short beep sounds.
Step 2 Enter the new independent access code to
An independent access code is a digit entered by the AE-100 digital keyboard to request entry into the residence. Up to 125 independent access codes can be set up with four digits.
four digits, then press #.
Step 3 Enter the new independent four-digit access code a second time to check for cation.
Step 4 Press #, two short beeps are ringing.
four digits a second time to check the cation.
Step 4 Press #.
Step 1 Enter function code 33 and press #, a short beep sounds.
Step 2 Enter the independent four-digit access code to erase, press #, a short beep sounds.
INDEPENDENT
Step 2 Enter the new independent access code to
This command erases a single independent access code.
four digits, then press #.
Step 3 Enter the independent four-digit access code a second time to delete, for verification.
Step 4 Press #, two short beeps are ringing.
four digits a second time to check the cation.
Step 4 Press #.
Step 1 Enter function code 34 and press #, a short beep sounds.
Step 2 Enter the numbers of all subunits (2, 3 and 4) to which you wish to copy data, then press #, a short beep sounds.
UNITS To synchronize the program- tion in multiunit facilities, it is possible to copy all data from the main unit to selected sub-units. This includes directory entries, independent access codes and all system options confi gations (except subunit numbers). NOTES: This utility command can only be executed from the main unit.
Step 2 Enter the numbers of all subunits (2,
3 and 4) to which you want to copy the data, then press #.
Step 3 Enter 5 to check cation, then press #, two short beeps ring. (Any entry other than 5# will cancel this order.)
To allow network communications in multi-unit systems, when running this remote over the phone, the system disconnects your call after step 3 and then copies data from the main unit to sub-units.
Step 3 Enter 5 for verification, then press #.
Enter
In order for this control to work, the system must be previously confided for installation with several units.
#
SYSTEM The default factory confi gation of the language is English. Three other languages can be chosen as the user language and the programming display language. NOTE: The system supports the posting of one language at a time.
Step 2 Enter: 1 for English (default language) 2 for Spanish 3 for French 4 for Portuguese Step 3 Press #.

FUNCTION CODE LOCAL PROGRAMMING BY TELEPHONE 70 MAXIMUM CONVERSATION TIME WITH THE
Step 1 Enter function code 70 and press #,
A short beep sounds.
" &
Step 2 Enter the new conversation time (010)
At 180 seconds) and press #, two short beeps sound.
Step 2 The posting indicates the conversation time currently
confi gure.Enter the new conversation duration (010 to 180 seconds).
If for some reason the resident does not press or hang up on the phone key, then the system will cut the line to the visitor after 60 seconds. Ten seconds and then five seconds before hanging up, a tone is heard on the phone line to remind the resident of the imminent cut. The resident can extend the conversation by pressing the # button on his/her phone. The duration before disconnection can be set between 10 and 180 seconds.
Step 3 Press #, two short beeps are ringing.
Step 3 Press #.
Step 1 Enter function code 71 and press #,
A short beep sounds.
Step 2 Enter the new relay operation time
(04 to 99 seconds).
Step 2 The display indicates the current operating time
The factory confederation allows the access relay to be operated for four seconds. The activation time can be set from 4 to 99 seconds for the various types of access control devices.
The system access relay. Enter the new time to activate the access relay (04-99 seconds).
Step 3 Press #, two short beeps are ringing.
Step 3 Press #.
Step 1 Enter function code 72 and press #,
A short beep sounds.
$ #
Step 2 Enter the new number of entry tests
The test results are shown in Table 1.
KEYBOARD The system counts the number of input tests by entering invalid access codes on the digital keyboard. If the number of tests exceeds the system-tolerated test, the keyboard shall be locked for 90 seconds. The factory default config for the number of tests before keyboard lock is three. The value of the number of tests possible may be one to nine.
Step 2 The display indicates the number of inlet tests
Step 3 Press #, two short beeps are ringing.
before the keyboard is locked. Enter the new number of tests to be tolerated (1-9 trials).
Step 3 Press #.

' (
AUTOMATIC The factory confederation allows the system to detect a tone signal on the telephone line and respond to the call.
Step 2 The display indicates the response setting
automatic.
Enter 0 to disable the automatic response.
Enter 1 to enable automatic response (default setting).
Step 3 Press #.
Step 1 Enter function code 75 and press
#, a short beep sounds.
$ ( (
Step 2 Enter 0 to disable the clicks of
Keyboard keys.
SPEAKER The factory confederation allows the speaker to make clicks of keys sound when pressing on the digital keyboard. This function can be disabled.
Step 2 Enter 0 to disable the click of the keys on
Enter 1 to activate the key-clicking button.
keyboard.
Enter 1 to enable the keyboard keys click (default setting).
Step 3 Press #, two short beeps
sound.
Step 3 Press #.
Step 1 Enter function code 76 and support
On #, a short beep sounds.
$ # ) "
Step 2 Enter 0 to disable the relay tone.
Enter 1 to activate the relay tone.
ACCESS RELAYS The factory confederation causes the transmission of a tone transmitted by the loudspeaker for two seconds when the access relay is activated. This function can be disabled.
Step 2 Enter 0 to disable the relay tone.
Step 3 Press #, two short beeps
Enter 1 to activate the relay tone (default setting).
sound.
Step 3 Press #.
( ( "
RESIDENTS The factory confederation allows residents to activate the access relay by pressing key 9 of their phone when they receive a call from Unit AE-100. This function can be disabled. If it is, then entry is only possible for them by entering their resident access code and independent access codes on the unit's digital keyboard.
Step 2 Enter 0 to disable relay control
access by the resident.
Enter 1 to enable the resident's access relay command (default setting).
Step 3 Press #.

FUNCTION CODE LOCAL PROGRAMMING BY TELEPHONE 91 OUTPUT OF MODE
Step 1 To exit the programming mode, enter
Step 1 To get out of the programming mode,
function code 91, then press #.
enter function code 91.
NOTES:
Step 2 Press #, three short beeps
The number of this command is entered and the unit is removed from the programming mode and returned to normal operating mode.
The AE-100 system automatically exits the programming mode after five minutes of inactivity.
sound.
Step 2 Enter function code 93 again for
Check cation, then press #. NOT AVAILABLE
This utility command permanently erases all independent access codes.
Step 1 Enter function code 95 and press
#, a short beep sounds.
(
Step 2 Enter 0 to disable the function of
The resident's callback function allows the AE-100 system to answer the phone and switch into speaker mode if the telephone calls occur within 60 seconds of most recent use of the Ae-100. This function gives residents the opportunity to call a visitor if they have just missed a call. The factory confi gation disables this function but it can be activated.
recall by the resident.
Step 2 The display indicates the current confi gation.
Enter 1 to enable the reminder function by the resident.
Enter 0 to disable the reminder function by the resident (default setting).
Step 3 Press #, two short beeps
Enter 1 to enable the reminder function by the resident.
sound.
Step 3 Press #.


If the visitor already knows the resident's directory number, first press the key and then enter the directory number to call the resident. If the visitor does not know the resident's directory number, he can challenge entries in the directory that appear alphabetically by pressing or . Press the directory from A to Z. Press defi late to challenge the directory from Z to A. The directory challenges the fastest when you press continuously on keys or . When the visitor finds the resident's directory number, he can press the key to call him. The system will call the resident's telephone number to establish a two-way communication. NOTES: Resident's telephone number is never posted
in front of the visitor. The resident responds to the call and speaks with the visitor about whether or not they should grant access to the residence. The resident can use his phone keyboard to grant access by operating the access relay; for this purpose he presses the key. After granting the entrance, the system stops communication with the visitor and calls from the resident. The resident can cut off his communication with the visitor without granting access by pressing or hanging up. NOTES: The communication cut by hanging up is not
recommended. The system then stays in control of the line until the maximum conversation time with the visitor is exhausted (this default duration was set at 60 seconds). The maximum conversation time with the visitor can be scheduled from 10 to 180 seconds. Ten and five seconds before disconnection, a tone is heard in the phone to remind the resident of the next cut. To restart the timer, a resident can press the button on his/her phone. Request for entry with an access code Residents and authorized personnel have up to 40 seconds to enter their access code.

PRESS THE STAR KEY FIRST TO RESET THE DIGITAL KEYBOARD (OPTIONAL), THEN ENTER THE DIRECTORY NUMBER OR INDEPENDENT ACCESS CODE.
EIGHT SECONDS ARE TOLERATED BETWEEN EACH KEYSTROKE.
MAXIMUM 40 SECONDS ARE ALLOWED TO ENTER A COMPLETE ACCESS CODE.
THE FOUR DIGITS MUST BE ENTERED, INCLUDING ZEROS AT THE BEGINNING.
IF YOU ARE WRONG, PRESS THE STAR KEY TO START ENTERING AGAIN.
THE DIGITAL KEYBOARD LOCKS AFTER A NUMBER OF INCORRECT ENTRIES.
Example: The access code has four digits and the code is 0042, user must enter "0 0 4 2". In case of error, press the key to reset the digital keyboard. Enter the correct code again. If the number of tests with an incorrect code exceeds the number that triggers locking on the digital keyboard, it locks and n- accepts more than 90 seconds. Reminder by the resident If the Resident's Reminder function is activated, the resident can call Unit AE-100 to speak with a visitor and grant entry. The callback must be made within 60 seconds of the visitor's missed call.
WHEN A CORRECT CODE IS ENTERED, ACCESS RELAYS ARE ACTIVATED.


Linear Limited Warranty This linear product is guaranteed against all manufacturing and labour defects for twenty-four (24) months. This guarantee is granted exclusively to wholesalers who purchase directly from Linear or via the normal linear distribution channels. Linear does not guarantee this product to consumers. Consumers must inquire with their distributor or reseller as to the nature of the warranty that they are given by the dealer or retailer, if any. Linear LLC does not incur any obligation or liability for indirect damage caused by, or in connection with the use or performance of, this product, as well as other consequential damages relating to loss of property and income, lost profits, and costs of removal, installation or relocation. All implied guarantees, including implicit warranties of market value and adaptation to a particular purpose or use shall be valid exclusively until the date on which the guarantee expires. Linear LLC's warranty is granted in lieu of any other explicit or implicit warranties. All product returns involving the warranty must be issued a Product Return Authorization Number (PRN). Please contact Linear Technical Services at 1-800-421-1587 for a NAPP and other important details.
NOTICE OF THE FEDERAL (USA) COMMUNICATION CONTROL AGENCY (FCC) Changes or modifications not explicitly described in this manual or not approved by the manufacturer may cancel the user's device licence. This equipment was tested and found to be in compliance with the FCC Part 15 regulations for Class B digital devices. These limits are intended to provide reasonable protection against interference harmful to residential facilities. This equipment generates, uses and can radiate energy in radio frequencies, and if it is not installed or used as directed, it may cause interference harmful to communications via radio. However, there is no guarantee that interference will not occur in a particular facility. If this equipment produces pests harmful to the reception of radio or television signals, which can be determined by stopping and re-starting the equipment, users are encouraged to try to remedy these noises in one of the following ways:
Reorientation or moving the receiving antenna. By increasing the distance between equipment and receiver. By connecting the equipment to a outlet of an electrical circuit different from that on which the receiver is connected. By consulting the distributor or a specialist radio/TV technician.
Derechos reservados Copyright © 2007 Linear LLC 227625 A
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.