EN
Linear logo
Official user manual

Linear Telephone Entry System (AE-2000)

20 pages·1.2 MB·Home Security System·PDF·ENDEFRITNLJA
Linear Telephone Entry System (AE-2000)
Table of Contents 80 sections AE-2000 · Telephone Entry & Access Control System · Installation Instructions · ✓ BUILT-IN RADIO RECEIVER · … ShowHide
Page 1 of the Linear Telephone Entry System (AE-2000) user manual — AE-2000
Page 1 · click to enlarge
Page 1
Linear Telephone Entry System (AE-2000) — AE-2000 diagram (page 1)
Fig. 1

AE-2000

Telephone Entry & Access Control System

Installation Instructions

USA & Canada (800) 421-1587 & (800) 392-0123

(760) 438-7000 - Toll Free FAX (800) 468-1340

www.linearcorp.com

Page 2 of the Linear Telephone Entry System (AE-2000) user manual — AE-2000
Page 2 · click to enlarge
Page 2

Contents Introduction The Model AE-2000 Telephone Entry & Access Control System is designed for use as a primary access control device for gated communities, parking garages, offi ce buildings, apartments, dormitories, hotels/motels, commercial buildings and recreational facilities. Housed in a locked, rugged stainless steel faced enclosure, the AE- 2000 features a lighted keypad with bright, easy-to-read graphics, a large backlit display with programmable welcome message, a built-in microphone, speaker, and provision for an optional color CCTV camera. The cabinet is monitored with a magnetic “tamper” switch. The four relay output channels can be programmed to control electric door strikes, magnetic locks, door & gate operators, or barrier gates. The system utilizes hands-free, full duplex telephone communications between visitors and residents for granting access. Complete access control event logging, access time restriction, access location restriction, and administration functions are also available to manage the installation. The AE-2000 is network ready. Multiple units can be interconnected on a 3-wire RS-485 network. Two Wiegand inputs are available for connection of 26, 30, or 31-bit Wiegand devices (card readers, etc.). Three sets of PBUS inputs are available for connection to Linear’s line of remote accessories.

Introduction 2 Operation 2 Hardware Features 3 Software Highlights 3 Feature Overview 3 Accessory Overview 4 PBUS Accessories 4 Wiegand Accessories 4 Component Locations 5 Wiring Diagram 6 Important Mounting Requirements 7 Entry System Mounting 8 Entry System Mounting (Continued) 9 Relay Output Wiring 10 Power, Battery, & Ground Wiring 11 RS-232 Port 11 Telephone Wiring 12 Optional Radio Antenna 12 Optional Postal Lock 13 Optional Color CCTV Camera 13 PBUS Accessories 14 Wiegand Accessories 14 Optional Network Connection 15 System Adjustments 16 System Diagnostics 16 Internal Controls 17 AE-2000 Operation 18 Specifi cations 19 Dimension Drawing 19 Troubleshooting 20 Linear Limited Warranty 20 FCC Notice 20

Operation In a typical installation, the unit’s memory would be programmed with each resident’s name and directory code number. Arriving visitors would use the keys on the AE-2000 to view the directory names and directory number for the desired resident. Upon selecting the directory number, the AE-2000 will automatically dial the resident’s telephone number and establish two-way voice communication between the visitor and the resident. The resident will then have the option to grant or deny access to the visitor by pressing a digit on their telephone. In addition to the telephone entry, the AE-2000 can grant access using entry codes at the local or remote keypads. Also remote receivers, card readers, and interior and exterior keypads can be used with the system. Block coded MegaCode® transmitters can be used to gain access through the AE-2000’s built-in or remote radio receivers. Each transmitter can be individually suspended or re-activated. The system’s clock/calendar can control access based on specifi c times and dates. Automatic relay activation can be scheduled. Access can be restricted to certain times and dates. Holiday access can be scheduled. The system’s event log records system activity for future reference.

Page 3 of the Linear Telephone Entry System (AE-2000) user manual — ✓ COMPUTER PROGRAMMABLE
Page 3 · click to enlarge
Page 3

✓ BUILT-IN RADIO RECEIVER

Variable gain, high-sensitivity receiver for wireless transmitters ✓ FOUR FORM “C” (N.O. & N.C) RELAYS

Four 3-amp dry contact relay outputs are provided to activate access devices, such as door strikes, magnetic locks, automatic doors, barrier gates, and automatic sliding gates. The relay outputs can also be used as specialty outputs for alarm contact shunting, operator obstacle triggering, and alarm activation. Each of the relays can also be manually activated from buttons on the AE-2000 circuit board. LED indicators display the status of each relay.

Each relay has 3-amp @ 24-volt rating ✓ FOUR REQUEST-TO-EXIT INPUTS

Activates access device for exiting using a hardwired switch ✓ FOUR SENSING INPUTS

For sensing door position to control door-ajar and alarm features ✓ BUILT-IN ANNUNCIATOR

Each relay channel has a request-to-exit input. These inputs are supplied for hardwire activation of the access devices. Typically a request-to-exit input is wired to a pushbutton inside of the access controlled area. When a person desires to exit, pressing the pushbutton will activate the output relay channel and trigger the access device. A loop detector for automatic gate operation can be connected to a request-to-exit input.

Chirps during keystrokes ✓ BUILT-IN MODEM

No add-on modem required for telephone communications with system ✓ RS-232 PORT

COM port for direct connection to a computer ✓ NETWORK SUPPORT

Multiple units can be connected together to share data ✓ EXPANSION INTERFACE SUPPORT

The sensing inputs connect to door switches that monitor whether the controlled door is open or closed.

Model AM-MIO accessory adds additional input and outputs to the AE-2000 ✓ ON-BOARD CLOCK/CALENDAR CIRCUIT

Stamps the event log data as it is stored in the system’s memory ✓ WIEGAND INPUTS

A modular connector is provided for telephone line connection to the unit’s built-in 33.6K baud modem. The system can be accessed remotely for programming and control over the standard telephone system using a personal computer with a modem. For system backup, a computer connected through the modem can store and retrieve the AE-2000’s memory data.

Two Wiegand format card reader inputs for connection to external devices. ✓ LINEAR PBUS SUPPORT

Three PBUS input/output ports for connection of up to 6 Linear accessories. ✓ CCTV COLOR CAMERA SUPPORT

Model CCM-1 accessory camera allows color video monitoring of the keypad area ✓ POWER FAILURE MONITOR

A modular connector is provided for the bi-directional 38.4K baud RS-232 port. The AE-2000’s RS-232 port connects to a personal computer’s COM port. System programming can be performed locally with a computer connected to the RS-232 port.

AC power input is monitored, power outages are recorded in the event log

✓ COMPUTER PROGRAMMABLE

No dedicated programmer required, program with a computer and a modem ✓ LARGE ENTRY CODE CAPACITY

The local keypad is the system’s primary keypad. The local keypad activates Relay Channel “A”, but can be programmed for any of the relays.

Up to 20,000 entry codes can be used for gaining access ✓ 2-8 DIGIT ENTRY CODE LENGTH

Flexible code length for different applications ✓ LARGE RESIDENT DIRECTORY CAPACITY

The AE-2000 cabinet has provisions for installing a U.S.P.S. postal lock for keyed mail carrier access. The postal lock will activate Relay Channel “A”, but can be programmed for any of the relays.

Up to 10,000 residents ✓ 2-4 DIGIT DIRECTORY NUMBER LENGTH

Directory number lengths can be customized for small or large installations ✓ LARGE TRANSMITTER CAPACITY

Linear’s Model MGT safety edge transmitter is compatible with the AE-2000. The MGT detects and transmits obstacle events to the AE-2000.

Up to 45,600 block coded and 20,000 individually enrolled Linear transmitters can be used for gaining access ✓ TRANSMITTER FACILITY CODE SUPPORT

Identifi es wireless transmitters by installation ✓ LARGE CARD CAPACITY

The AE-2000’s fl ash memory retains all entry codes, transmitter information, card access, and programming, even without power.

Up to 45,600 block coded and 20,000 individually enrolled cards can be used for gaining access ✓ FOUR INDEPENDENT RELAY CHANNELS

The system programming can be accomplished by a computer and modem using Linear’s AccessBase2000 programming software.

Each output’s action is programmable ✓ PROGRAMMABLE TIME SCHEDULED RELAY ACTIVATION

The system supports a 12-volt battery backup or uninterruptable power supply for operation during power outage. The system does not charge the backup battery, an external battery charger is required to maintain the battery.

Activation for up to four time periods for each of the 31 system time zones ✓ PROGRAMMABLE TIME ZONE ACCESS VALIDATION

Validation during four time periods for each of the 31 system time zones ✓ PROGRAMMABLE VALIDATION DAYS

Select days of the week access is allowed ✓ PROGRAMMABLE HOLIDAY DAYS

Multiple AE-1000, AE-2000, & AM-3 units can be networked together via RS-485 allowing information sharing between the units. Networked units are interconnected with a three-wire cable. A common event log is retained for all of the networked units.

Select up to 24 expiring & 24 non-expiring holidays for access restriction ✓ OBSTACLE TRANSMITTER SUPPORT

Compatible with Linear’s Model MGT transmitter ✓ EVENT LOG

Stores up to 20,000 system events in memory for record keeping ✓ DELETED CARDHOLDER DATABASE

Three 6-wire Linear PBUS input/output ports are available to connect to several accessories (keypads, proximity readers, remote receivers). A typical application for a remote keypad or reader would be to control additional doors or gates.

System logs deleted cardholders for future identifi cation ✓ TIMED ANTI-PASSBACK

Disables entry code for a programmed time after use

Show 16 more labels / short text on this page
Hardware Features · Feature Overview · Relay Outputs · Request-to-Exit Inputs · Sensing Inputs · Built-in Modem · RS-232 Communications Port · Software Highlights · Local Keypad · Postal Lock · Obstacle Detection · Programming Memory · Computer Programming · Battery Backup · Network Support · Linear PBUS Ports
Page 4 of the Linear Telephone Entry System (AE-2000) user manual — READER
Page 4 · click to enlarge
Page 4

Accessory Overview PBUS Accessories Several compatible accessories are available to connect to the AE-2000’s three 6-wire communications “PBUS” inputs. Up to six PBUS accessories can be used with each AE-2000 unit.

AM-RRR Remote Radio Receiver For wireless transmitters, connect the Model AM- RRR high-gain superheterodyne UHF receiver. The receiver is housed in a weather-resistant enclosure and can be mounted indoors or outdoors. Gaskets and a weather-tight wiring strain relief seal the unit from the elements. AM-RPR Radio Proximity Receiver The Model AM-RPR functions as a remote device that supplies localized radio reception for the AE-2000 In a typical installation, the AM-RPR would be mounted in a plastic single-gang electrical box next to the controlled opening. When the user requires access, their transmitter must be activated within three inches of the AM-RPR faceplate. AM-KP Exterior Keypad The Model AM-KP is housed in a rugged cast aluminum enclosure designed for exterior installations. The die-cast keys have bright, easy-to-read yellow graphics. The keypad can be mounted to a pedestal or directly to a wall. A keylock secures the keypad to the mounting backplate. AM-KPI Interior Keypad The Model AM-KPI keypad is housed in a rugged, plastic enclosure designed to be mounted indoors in a standard single-gang electrical box. Tamper resistant screws secure the keypad to its mounting plate. The die-cast keys have bright, easy-to-read yellow graphics and is illuminated with white LEDs.The keypad is supplied with a satin-chrome bezel and three interchangeable colored bezels (white, ivory, & bronze) to customize the keypad appearance for the installation. AM-CRI Card Reader Interface The Model AM-CRI expands the standard two AE-2000 Wiegand inputs by supporting one or two additional 26-bit Wiegand input devices per AM-CRI interfaces used.

EXA-2000

REMOTE

RADIO ANTENNA

AM-RRR REMOTE

RADIO RECEIVER

AM-RRR

AE-2000 TELEPHONE ENTRY & ACCESS CONTROL

SYSTEM

AM-RPR

AM-KP

WIEGAND ACCESSORIES

PBUS ACCESSORIES

AM-KPI

AM-KPI INTERIOR

AM-WOR WIEGAND

AM-CRI

KEYPAD

OUTPUT RECEIVER

Wiegand Accessories Two Linear accessories are available to connect WIEGAND format devices to the AE-2000. Most other manufacturer’s 26, 30 & 31-bit WIEGAND output devices can also be used with the AE-2000.

AM-PR PROXIMITY

WOR Wiegand Output Radio Receiver For block-coded Linear wireless transmitters, connect the Model WOR high-gain superheterodyne UHF receiver. The receiver is housed in a weather- resistant enclosure and can be mounted indoors or outdoors. Gaskets and a weather-tight wiring strain relief seal the unit from the elements. AM-PR Proximity Reader The Model AM-PR is a radio-based reader that works with either proximity tags (Model AM-PT) or proximity cards (Model AM-PC), both of which are slotted to attach to key rings. Upon reading a user’s tag or card, it transmits the entry data via a Wiegand output to the AE-2000. An integral LED confi rms to the user that access is granted.

READER

AM-KP EXTERIOR

KEYPAD

WOR

AM-RPR

AM-CRI

RADIO PROXIMITY

CARD READER INTERFACE

RECEIVER

AM-PR

* · 0 # · *

Page 5 of the Linear Telephone Entry System (AE-2000) user manual — Component Locations
Page 5 · click to enlarge
Page 5

Component Locations

Linear Telephone Entry System (AE-2000) — Component Locations diagram (page 5)
Fig. 2 · Component Locations

FOR EASY WIRING, THE UNIT'S TERMINAL BLOCKS CAN BE UN-PLUGGED FROM THE CIRCUIT BOARD

Page 6 of the Linear Telephone Entry System (AE-2000) user manual — Wiring Diagram
Page 6 · click to enlarge
Page 6

Wiring Diagram

Linear Telephone Entry System (AE-2000) — Wiring Diagram diagram (page 6)
Fig. 3 · Wiring Diagram

THIS WIRING EXAMPLE SHOWS: DOOR ACCESS WITH A DOOR STRIKE ON RELAY CHANNEL "A" DOOR ACCESS WITH A MAGNETIC LOCK ON RELAY CHANNEL "B" GATE ACCESS WITH A GATE OPERATOR ON RELAY CHANNEL "C" (YOUR INSTALLATION MAY VARY)

RELAY RATING3 AMPS @ 30 VOLTS AC/DC MAXIMUM
Page 7 of the Linear Telephone Entry System (AE-2000) user manual — EDGE OF TRAFFIC LANE
Page 7 · click to enlarge
Page 7

Mounting Environment Consider the environmental factors at the desired mounting location. The AE-2000 is designed for direct outdoor installations, however, it is preferable to protect the unit from extreme exposure to sun, driving rain, or snow whenever possible. Mounting the unit in a kiosk can provide extra environmental protection.

Follow Building Codes Check all local building codes and ordinances prior to installing the system. Proper installation of the AE-2000 conforming to the local building codes for access control equipment is a regulatory requirement. The AE-2000 installation is an extremely important and integral part of the overall access control system.

Linear Telephone Entry System (AE-2000) — 10 FEET MINIMUM diagram (page 7)
Fig. 4

Mounting Location If the AE-2000 is used to control a door or pedestrian gate, locate the unit as near as practical to the entry point. If the unit is mounted on or in a wall adjacent to the entry point, be sure the wall is sturdy. The repeated shock and vibration from a slamming access door or spring-loaded pedestrian gate must be isolated from the AE-2000. NEVER MOUNT THE UNIT DIRECTLY TO A MOVING DOOR OR GATE!

Linear Telephone Entry System (AE-2000) — 10 FEET MINIMUM diagram (page 7)
Fig. 5

Gate Installations If the AE-2000 is used to control a gate operator connected to a vehicular gate, the unit MUST be mounted AT LEAST 10 feet away from the gate (open and closed) and gate operator. AT NO TIME SHOULD A PERSON BE ABLE TO TOUCH THE GATE OR GATE OPERATOR AND THE AE-2000 AT THE SAME TIME.

10 FEET MINIMUM

Vehicle Traffi c Do not mount the AE-2000 where it extends into any traffi c lane. Locate the gooseneck pedestal or entry kiosk so all parts of the AE-2000 are outside the traffi c lane. Locate the AE-2000 clear of any turn-around lanes vehicles use when access is denied.

EDGE OF TRAFFIC LANE

Americans with Disability Act (A.D.A.) Requirements THE FOLLOWING WHEELCHAIR ACCESS REQUIREMENTS ARE FOR PUBLIC DOOR CONTROL INSTALLATIONS ONLY.

1. If the clear fl oor space allows only forward approach to the system, the maximum high forward reach allowed is 48” above grade to the top of the keypad. 2. If the high forward reach to the system is over an obstruction of greater than 20” but less than 25”, the maximum high forward reach allowed is 44” above grade to the top of the keypad. 3. If the clear fl oor space allows parallel approach by a person in a wheelchair, the maximum high side reach shall be 54” above grade to the top of the keypad. 4. If the high side reach is over an obstruction of 24” or less, the maximum high side reach allowed is 46” above grade to the top of the keypad.

Page 8 of the Linear Telephone Entry System (AE-2000) user manual — 10 FEET MINIMUM
Page 8 · click to enlarge
Page 8

Entry System Mounting The AE-2000 cabinet is designed to be mounted three ways:

Linear Telephone Entry System (AE-2000) — 10 FEET MINIMUM diagram (page 8)
Fig. 6
  • The unit can be mounted directly to a wall or fl at surface.
  • The unit can be mounted recessed into the wall.
  • The unit can be mounted on a standard gooseneck pedestal. Choose a well lit location near the controlled opening. Wiring access for power, telephone, earth ground, control output must be available to the mounting location. If the optional remote accessories are used, wiring access for these cables must also be available to the mounting location.

LOOSEN THE TOP TWO NUTS & REMOVE THE BOTTOM TWO NUTS

Opening and Closing the Cabinet The AE-2000’s cabinet hinges are spring loaded to help weather seal the cabinet. To open the cabinet, press the cabinet door fi rmly around each lock while turning each key counterclockwise. To close the cabinet, press the cabinet door fi rmly around each lock while turning each key clockwise.

CAREFULLY REMOVE THE FIVE WIRING HARNESS CONNECTORS & GROUND WIRE

Mounting Preparation Before mounting the system, the main circuit board mounting plate must be removed to provide access for the wiring hole and mounting fasteners.

✦ CAUTION!Touch a grounded object before proceeding to
  • discharge static electricity from your body. 1. Carefully remove the fi ve main circuit board wiring connectors:
  • The CPU/interface ribbon cable connector.
  • The processor module power connector.
  • The telephone interface connector.
  • The tamper switch connector.
  • The keypad power connector. 2. Remove the nut from the Earth Ground stud and remove the green ground wire lug from the stud. 3. Remove the two bottom circuit board mounting plate nuts. 4. Loosen the two top circuit board mounting plate nuts. 5. Carefully lift up on the mounting plate, removing the circuit board mounting plate. Set it aside in a safe place. Reverse these steps to replace the circuit board mounting plate after the cabinet mounting is complete.
Linear Telephone Entry System (AE-2000) — 10 FEET MINIMUM diagram (page 8)
Fig. 7

Surface Mounting The cabinet can be mounted on a wall or any suitable fl at surface. The four 3/8” mounting holes or the four self-drill locations can be used to attach the cabinet to the surface.

1. For wall mounting, hold the cabinet at the approximate mounting location where the display will be about eye level or slightly above. 2A. If using the 3/8” mounting holes, mark the four mounting hole centers. Drill as required. Use the appropriate fasteners for the mounting surface to secure the cabinet. 2B. If using the self-drill mounting holes, choose the correct size bit for the fasteners and drill the cabinet as required. Use the appropriate fasteners for the mounting surface to secure the cabinet. 3. After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire.

ATTACH THE CABINET WITH APPROPRIATE HARDWARE FOR THE MOUNTING SURFACE

Page 9 of the Linear Telephone Entry System (AE-2000) user manual — 10 FEET MINIMUM
Page 9 · click to enlarge
Page 9

Entry System Mounting (Continued) Recessed Mounting The cabinet can be mounted recessed using the accessory trim-ring (P/N ACP00914). The trim-ring mounts in the wall and the cabinet attaches to the trim-ring.

Linear Telephone Entry System (AE-2000) — 10 FEET MINIMUM diagram (page 9)
Fig. 8

DETERMINE LOCATION FOR THE 15-½" x 19" MOUNTING HOLE

1. Identify the location of any studs in the wall. 2. Cut a 15-½” wide by 19” high rectangular hole between studs at the mounting location. 3. Install any additional mounting material required to provide surfaces inside the wall 15-½” apart for attaching the trim-ring. 4. Place the trim-ring in the wall hole. Check for level, then attach the trim-ring with up to six screws into the side tabs. 5. Drill the cabinet’s six self-drill mounting holes the appropriate size for the hardware. 6. Attach the cabinet to the trim-ring using self-tapping screws. 7. After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire.

4 INSTALL ANY SHIMS TO ALLOW MOUNTING AND ATTACH THE TRIM-RING WITH UP TO 6 SCREWS

DRILL 3/16" HOLES IN THE CABINET AT THE PRE-MARKED LOCATIONS

ATTACH THE CABINET TO THE TRIM-RING WITH SELF-TAPING SCREWS

Pedestal Mounting The cabinet can be mounted on a gooseneck pedestal. Linear manufacturers two pedestals: Model GNC-1 is for surface mounting with concrete fasteners, Model GNB-1 is for burial mounting. When mounting to a pedestal, use the cabinet reinforcing plate to stiffen the cabinet.

Linear Telephone Entry System (AE-2000) — 10 FEET MINIMUM diagram (page 9)
Fig. 9

ALIGN THE REINFORCING PLATE ON THE INSIDE OF THE CABINET

1. Install the pedestal at the desired location. 2. Place the reinforcing plate inside the cabinet. 3. Use security hardware to attach the cabinet and reinforcing plate to the pedestal. 4. After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire

USE SECURITY HARDWARE TO ATTACH THE PLATE AND CABINET TO THE PEDESTAL

Page 10 of the Linear Telephone Entry System (AE-2000) user manual — RTE
Page 10 · click to enlarge
Page 10

Relay Output Wiring Any of the four relay outputs channels (A-D) can be used to control access devices on doors or gates.

TYPICAL DOOR STRIKE HOOKUP

RELAY TERMINALS

ELECTRIC

GND DS N.O. COM N.C.

Door or Pedestrian Gate Control

DOOR STRIKE

1. Install a low voltage electric door strike or magnetic lock as a locking device for the door or pedestrian gate. 2. Install the power supply or transformer for the locking device. DO NOT POWER THE AE-2000 FROM THIS POWER SUPPLY. 3. Connect one wire from the power supply to one wire from the locking device. 4. Route two wires between the locking device and the AE-2000. Connect one wire to the remaining wire of the locking device. Connect the other wire to the remaining wire of the power supply. 5A. For a door strike, connect the wires to the AE-2000 relay COM & N.O. terminals. 5B. For a magnetic lock, connect the wires to the AE-2000 relay COM & N.C. terminals. Gate Control

DOOR STRIKE POWER SUPPLY

RTE

TYPICAL MAGNETIC LOCK HOOKUP

MAGNETIC

GND DS N.O. COM N.C.

DOOR

LOCK

DOOR

LOCK POWER SUPPLY

RTE

1. Route two wires between the gate and the AE-2000. 2. Connect the gate operator’s OPEN terminals to the AE-2000 relay COM & N.O. terminals. ✦ NOTE: For operator wiring specifi cs, refer to the gate operator’s

TYPICAL AUTOMATIC GATE HOOKUP

GND DS N.O. COM N.C.

OPEN

wiring diagram.

GATE OPERATOR

Request-to-Exit Inputs Each of the four relay outputs has a request-to-exit input terminal. Grounding this terminal will activate the associated relay. Exit request inputs are typically used with push bars, loop sensors, or pushbuttons.

RELAY RATING3 AMPS @ 30 VOLTS AC/DC MAXIMUM

RTE

1. Install the pushbutton or device to signal an exit request. 2. Route two wires from the device to the AE-2000. 3. Connect the device’s normally open output to the wires. 4. To activate a relay channel, connect the wires to the associated relay request-to-exit terminal ( RTE-A, RTE-B, RTE-C, or RTE-D ) and GND terminals. Sensing Inputs The sensing inputs can connect to a door switch that monitors whether the controlled door is open or closed.
Linear Telephone Entry System (AE-2000) — RTE diagram (page 10)
Fig. 10
1. To use the door sense feature to detect forced entry or door ajar conditions, install a normally closed door switch on the door or pedestrian gate and route two wires from the switch to the AE-2000. 2. Connect the sensing device wires to the associated relay sensing terminal ( DS-A, DS-B, DS-C, or DS-D ) and GND terminals.
Page 11 of the Linear Telephone Entry System (AE-2000) user manual — AE-2000 RS-232 PORT
Page 11 · click to enlarge
Page 11

Power, Battery, & Ground Wiring Power Wiring

✦ NOTEDO NOT APPLY POWER UNTIL THE INSTALLATION IS
  • COMPLETE. TURN MASTER POWER SWITCH OFF BEFORE WIRING. 1. Route two wires between the AE-2000 and the power transformer.
  • For power wire runs up to 75 feet, use 18 AWG, THHN 600-volt insulated wire.
  • For power wire runs up to 150 feet, use 16 AWG, THHN 600-volt insulated wire. 2. Connect the wires to the transformer. Connect the other end of the wires to the AE-2000 AC1 & AC2 terminals. Backup Battery / Uninterruptable Power Supply Use of battery backup is optional. It will allow the AE-2000 to operate for short periods of time without AC power. The door or gate access device must use some type of battery backup of its own for the entire system to be functional. A backup battery will not fi t into the AE-2000 case. Protect the backup battery inside a rain-tight NEMA enclosure suitable for the installation.

POWER TERMINALS

AC2

AC1

DC

DC

EARTH GROUND

STUD

EARTH GROUND

STAKE 12 VOLT BATTERY

NOTE: THE OPTIONAL

BACKUP BATTERY

✦ NOTEA backup battery is not required to maintain the AE-2000

WILL REQUIRE AN EXTERNAL CHARGER

clock/calendar and programming memory during power outages. 1. Route two wires between the AE-2000 and the backup battery. 2. Connect the Battery positive to the AE-2000 DC+ terminal and the negative to the DC- terminal. ✦ NOTE: The AE-2000 does not supply battery charging current.

16 VAC 50 VA TRANSFORMER

An external battery charger will be required to maintain the battery.

Earth Ground For the best ground, use size 12 gauge solid wire or larger to connect to an 8-foot copper ground rod. Locate the ground rod next to the Power and Telephone company rods and bond the rods together with a new clamp. Do not disturb the clamps installed by the Power or Telephone Company. Alternately, connect to a metallic cold water pipe for the earth ground.

1. Connect the wire from the earth ground to the AE-2000’s EARTH GROUND STUD . RS-232 Port A modular connector is provided for the bi-directional 38.4K baud RS-232 port. The AE-2000’s RS-232 port connects to a personal computer’s COM port. System programming can be performed locally with a computer connected to the RS-232 port using the AccessBase 2000 software.

AE-2000 RS-232 PORT

COMPUTER'S

COM PORT

SET COMPUTER COM PORT

LINEAR MODEL A2C SERIAL COMPUTER CABLE

BAUD RATE TO 38,400 BPS

Page 12 of the Linear Telephone Entry System (AE-2000) user manual — Power, Battery, & Ground Wiring Power Wiring
Page 12 · click to enlarge
Page 12

Telephone Wiring For telephone entry and programming, the AE-2000 connects to a standard telephone line.

Linear Telephone Entry System (AE-2000) — Power, Battery, & Ground Wiring Power Wiring diagram (page 12)
Fig. 11 · Power, Battery, & Ground Wiring Power Wiring
  • DO NOT ROUTE TELEPHONE AND AC WIRING INSIDE THE SAME CONDUIT . Route all telephone wires inside a dedicated conduit that is at least six inches away from any AC line wiring.
  • All telephone wiring must be made on the “building” side of the telephone company’s demarcation device (the terminal block where the telephone line connects to the building).
  • If any security system or personal alert system at the installation is connected to the telephone line, be sure that it is connected to the line ahead of the AE-2000 using a RJ-31X or RJ-38X interface.
  • Use only high-quality telephone wire. All telephone wire should be twisted-pair with a minimum size of 24 AWG. Typical Telephone Wiring

1A. If using the AE-2000 modular connector for the telephone connection, connect a double-ended modular cable between the AE-2000’s PHONE jack and the modular telephone jack wired to the installation’s telephone line. 1B. If using the AE-2000 terminal block for the telephone connection, connect the “ring” wire (usually red) to the RING terminal, connect the “tip” wire (usually green) to the TIP terminal.

Optional Radio Antenna If wireless transmitters are going to be used in the system a remote antenna must be installed to provide reception for the AE-2000. A basic antenna kit is supplied with the AE-2000. The kit contains a whip antenna, connector, and a 36” length of coax cable. The antenna connector should be mounted on a metal surface using a 3/8” hole. Two other models of antennas are compatible with the AE-2000. The Model EXA-1000 is a non-directional antenna. The Model EXA-2000 is a directional antenna used in installations where transmitted signals are desired to be received only in a particular direction.

Linear Telephone Entry System (AE-2000) — Power, Battery, & Ground Wiring Power Wiring diagram (page 12)
Fig. 12 · Power, Battery, & Ground Wiring Power Wiring
✦ NOTEUp to 50 feet of type RG-59 coax can be used to connect

the antenna to the AE-2000. Keep the coax as short as possible. 1. Install the antenna. (See installation instructions if using the EXA-1000 or EXA-2000.) 2. Connect the antenna coax cable to the antenna and route the cable to the AE-2000. 3. Connect the cable to the AE-2000’s ANTENNA connector. Receiver Range Control The AE-2000 has a RECEIVER RANGE adjustment knob. In some installations, it may be necessary to reduce the effective radio range of the receiver to limit the distance that transmitters can be used. Reducing the radio’s sensitivity may also help in installations where unwanted interference is overpowering signals from transmitters.

1. After the installation and system programming is complete, adjust the RECEIVER RANGE knob to suit the installation. Test transmitters from typical locations that they will be used. Set the radio range so the receiver can activate from transmitters from about 25% more distance than required.
Page 13 of the Linear Telephone Entry System (AE-2000) user manual — Power, Battery, & Ground Wiring Power Wiring
Page 13 · click to enlarge
Page 13

Optional Postal Lock A postal lock can be installed in the AE-2000 Entry System to provide keyed access for the postal service. The AE-2000 case is designed to accept a U.S. Postal Service postal lock. When the postal lock is engaged, the programmed output relay will activate.

Linear Telephone Entry System (AE-2000) — Power, Battery, & Ground Wiring Power Wiring diagram (page 13)
Fig. 13 · Power, Battery, & Ground Wiring Power Wiring

1. After opening the cabinet, re-lock the left cabinet lock to provide clearance to remove the postal lock switch plate. 2. Remove the four locknuts that retain the postal lock switch plate, hole cover plate, and block (below the left cabinet lock on the AE-2000 faceplate). The hole cover plate and block will not be used and can be discarded. 3. Remove the switch plate from the four studs. 4. Install the postal lock assembly onto the four studs. The postal lock’s moving plunger should point down (see fi gure). 5. Replace the postal lock switch plate with the microswitch oriented toward the front of the cabinet where it will be pressed by the postal lock’s moving plunger (see fi gure). 6. Secure the postal lock and switch plate with the four locknuts. ✦ NOTE: Be sure the postal lock’s plunger actuates the

REPLACE PLATE WITH THE MICROSWITCH TOWARDS THE FRONT OF THE CABINET, REPLACE LOCKNUTS

microswitch. Adjust the switch plate and the postal lock then test the action until the microswitch fully actuates. 7. Tighten the four locknuts after the adjustment and testing is complete. 8. When programming the system, set the postal lock option to activate the desired relay output.

Optional Color CCTV Camera Linear’s Model CCM-1 (P/N ACP00904) CCTV camera can be installed inside the AE-2000 Entry System. The camera provides a video signal for viewing the area in front of the entry system. The CAMERA connector is used to connect the camera to the AE-2000. The 4-conductor cable routes power to, and video from the camera. The VIDEO jack is the camera output for connection to a video cable with a Type “BNC” connector. Up to 400 feet of 75-ohm RG-59 video cable can be used. Longer cable runs may require the use of a video amplifi er.

Linear Telephone Entry System (AE-2000) — Power, Battery, & Ground Wiring Power Wiring diagram (page 13)
Fig. 14 · Power, Battery, & Ground Wiring Power Wiring

1. Remove the two plate locknuts from the camera mounting studs above the right keylock on the AE-2000 faceplate. 2. Remove the cover plate. 3. Remove the protective backing from the plastic window included with the camera and install the plastic window onto the studs with the adhesive side against the door. 4. Remove the lens cap from the camera. 5. Mount the camera assembly on the two studs, with the alignment hole in the camera bracket towards the top. Secure the camera with the two locknuts. 6. Connect the camera’s cable to the AE-2000’s CAMERA connector. 7. Connect the video cable to the AE-2000’s VIDEO connector. 8. Connect the other end of the video cable to the viewing monitor or the video distribution system.

REMOVE PROTECTIVE BACKING AND APPLY WINDOW WITH ADHESIVE SIDE AGAINST DOOR

ATTACH CAMERA WITH TWO NUTS CONNECT CAMERA WIRING HARNESS

Postal Lock Installation · Camera Installation

Page 14 of the Linear Telephone Entry System (AE-2000) user manual — Power, Battery, & Ground Wiring Power Wiring
Page 14 · click to enlarge
Page 14

PBUS Accessories Six accessories (keypads, proximity readers, remote receivers) can be connected to the AE-2000’s three PBUS input/output ports. A typical application for a remote keypad would be to control a second door or gate. Linear’s PBUS devices compatible with the AE-2000 are:

Linear Telephone Entry System (AE-2000) — Power, Battery, & Ground Wiring Power Wiring diagram (page 14)
Fig. 15 · Power, Battery, & Ground Wiring Power Wiring
  • AM-RRR Remote Radio Receiver
  • AM-RPR Radio Proximity Receiver
  • AM-KP Exterior Keypad
  • AM-KPI Interior Keypad
  • AM-CRI Card Reader Interface 1. Mount and install the accessory as described in its installation instructions. 2. Route 6-conductor cable from the AE-2000 to the accessory.
  • For wire runs up to 300 feet use 24 AWG Belden Type 9931 or equivalent.
  • For wire runs up to 600 feet use 20 AWG Weico Type 9405 or equivalent. 3. Set the DEVICE ADDRESS rotary switch in the accessory to a unique address number. When programming the system, the device address number will identify each PBUS accessory to the AE-2000. 4. Connect the 6-conductor cable to the accessory and the AE-2000.

SET THE REMOTE DEVICE ADDRESS SWITCH TO A UNIQUE DEVICE ADDRESS

Wiegand Accessories The two AE-2000 Wiegand inputs (WIEGAND A & B) can connect to a large variety of 26, 30, and 31-bit Wiegand output accessories. The Wiegand format is a common standard for access control equipment. A typical application would be to add swipe card or proximity readers to the system.

Linear Telephone Entry System (AE-2000) — Power, Battery, & Ground Wiring Power Wiring diagram (page 14)
Fig. 16 · Power, Battery, & Ground Wiring Power Wiring
✦ NOTEDepending on the Wiegand accessory used, the LED1,
  • LED2, and HOLD connections may not be required.
  • LED1 output is switched to ground during non-access time.
  • LED2 output is switched to ground for one second during access time. 1. Mount and install the Wiegand accessory as described in its installation instructions. 2. Route a cable from the AE-2000 to the accessory.
  • For wire runs up to 300 feet use 24 AWG Belden Type 9931 or equivalent.
  • For wire runs up to 500 feet use 20 AWG Weico Type 9405 or equivalent. 3. Connect the cable to the accessory and the AE-2000 as shown in the fi gure.
Page 15 of the Linear Telephone Entry System (AE-2000) user manual — Power, Battery, & Ground Wiring Power Wiring
Page 15 · click to enlarge
Page 15

Optional Network Connection Linear’s AE-1000, AE-2000, & AM-3 Access Control Systems can be connected together in a network. A network will allow sharing programming and user information between the systems. Network wiring conforms to 3-wire RS-485 electrical specifi cations. Units connected in the network can be wired using one unit as a “hub” or by wiring from one unit to the next in “daisy-chain” fashion. See the fi gures for wiring options.

Linear Telephone Entry System (AE-2000) — Power, Battery, & Ground Wiring Power Wiring diagram (page 15)
Fig. 17 · Power, Battery, & Ground Wiring Power Wiring

ACCESS CONTROL HOMERUN NETWORK USING ONE UNIT AS A NETWORK MASTER

  • Use Belden 9925 or Carol C0600 shielded cable or equivalent. Maximum wire run distance is 4000 feet. ✦ NOTE: Be sure to connect the cable’s shield to one of the GND

terminals.

1. Mount and install the units for the network. 2. Choose one unit to be the Network Hub. Usually this would be a centrally located or “main” unit. 3. Route 3-conductor shielded cable from the hub unit to one of the other units. Repeat this step to connect the hub unit to each of the other units. 4. Connect the 3-conductor cable to each unit’s NETWORK terminals. Network Daisy-chain
1. Mount and install the units for the network. 2. Route 3-conductor shielded cable from one unit to the next unit until there is cabling run to all of the units. 3. Connect the 3-conductor cable to each unit’s NETWORK terminals.
Linear Telephone Entry System (AE-2000) — Power, Battery, & Ground Wiring Power Wiring diagram (page 15)
Fig. 18 · Power, Battery, & Ground Wiring Power Wiring

Network with Hub

Page 16 of the Linear Telephone Entry System (AE-2000) user manual — READER "A"
Page 16 · click to enlarge
Page 16

System Adjustments The factory settings are suffi cient for most installations. The system can be adjusted to customize the installation.

Linear Telephone Entry System (AE-2000) — STATUS/PROGRAM diagram (page 16)
Fig. 19

System Volume Adjustment The sound level of the synthesized voice and key beep can be adjusted.

1. Locate the SYSTEM VOLUME adjustment on the CPU circuit board. 2. Press keys on the keypad while adjusting the control until the sound is at the desired level. Turn the adjustment clockwise for more volume, counterclockwise for less volume. 2-Way Audio Volume Adjustment If the resident’s voice from the speaker is too loud or not loud enough, the speaker’s volume can be adjusted.
1. Locate the 2-WAY AUDIO VOLUME adjustment on the CPU circuit board. 2. Make a directory number call to test the speaker volume. While listening to the resident’s voice, turn the adjustment clockwise for more volume, counterclockwise for less volume. System Restart Button Pressing the SYSTEM RESTART button will reboot the system’s microcontroller. NO SYSTEM INFORMATION WILL BE ERASED.

Display Contrast Adjustment If the lighting in the area or the viewing angle of the display in the installation causes the display to look too dark or too light, the display’s contrast can be adjusted.

1. Press the 1, 5 & 9 keys at the same time. The system will assume Contrast Adjustment Mode for 15 seconds. 2. Press the up and down arrow keys until display has the best visibility. 3. Press the or key to exit Contrast Adjustment Mode. System Diagnostics Several components on the main circuit board are for monitoring the system during operation. When calling for technical assistance, Linear’s Technical Services Department may ask the installer to use these components to diagnose the system.

STATUS/PROGRAM

HOST ON-LINE

DISPLAY

ACCESS GRANTED

VALIDATE

DECODE

On-board Indicators 17 LED indicators are on the main circuit board. Refer to the fi gure for the location of each indicator.

RADIO

RELAY "A"

ACTIVE

  • STATUS/PROGRAM DISPLAY shows supervisory and status conditions, also used for some local programming.
  • ACCESS GRANTED lights when a credential is validated and access is granted.
  • HOST ON-LINE lights when the Host PC is connected to the Master Node.
  • VALIDATE lights when a credential is determined to be valid.
  • DECODE lights when a credential has been successfully decoded.
  • RADIO fl ashes when data or interference is received by the built-in radio.
  • RELAY “A” ACTIVE lights when the Channel “A” relay is energized.
  • RELAY “B” ACTIVE lights when the Channel “B” relay is energized.
  • RELAY “C” ACTIVE lights when the Channel “C” relay is energized.
  • RELAY “D” ACTIVE lights when the Channel “D” relay is energized.
  • POWER lights when AC or DC power is present.
  • OFF-HOOK lights when the system has the incoming telephone line seized.
  • TALK lights when the system is communicating over the telephone line.
  • NETWORK fl ashes in response to network traffi c.
  • PBUS blinks when any PBUS device is successively decoded.
  • READER “B” fl ashes when Wiegand B device is successfully decoded.
  • READER “A” fl ashes when Wiegand A device is successfully decoded.

READER "A"

RELAY "B"

READER "B"

ACTIVE

AE-2000 MAIN CIRCUIT BOARD

PBUS

RELAY "C"

ACTIVE

RELAY "D"

NETWORK

ACTIVE

POWER OFF HOOK TALK

Page 17 of the Linear Telephone Entry System (AE-2000) user manual — STATUS/PROGRAM
Page 17 · click to enlarge
Page 17

Internal Controls On-board Pushbuttons Seven pushbuttons are on the main circuit board. Refer to the fi gure for the location of each pushbutton.

Linear Telephone Entry System (AE-2000) — STATUS/PROGRAM diagram (page 17)
Fig. 20
  • “UP” BUTTON adds one to the value on the STATUS/PROGRAM display.
  • “DOWN” BUTTON subtracts one from value on the STATUS/PROGRAM display.
  • RELAY “A” LATCH press to latch relay “A”, press again to un-latch.
  • RELAY “B” LATCH press to latch relay “B”, press again to un-latch.
  • RELAY “C” LATCH press to latch relay “C”, press again to un-latch.
  • RELAY “D” LATCH press to latch relay “D”, press again to un-latch.
  • ENTER BUTTON press to accept the value on the STATUS/PROGRAM display during programming, press to clear an indication during the supervisory display.

On-board Display The STATUS/PROGRAM display will show system conditions and can be used to aid system setup.

Status Mode While the system is running, the display will show the current system status. Normally the left digit will show a moving pattern and the right digit will show the unit’s Network Node number. When a supervisory condition exists, the display will cycle to show the condition(s). When an item is displayed, press the ENTER button to clear the display (clears the display only, the condition may still exist). Refer to the following table for the supervisory condition display codes.

Linear Telephone Entry System (AE-2000) — STATUS/PROGRAM diagram (page 17)
Fig. 21

Program Mode Options for up to ten system settings can be controlled in Program Mode. By viewing the STATUS/PROGRAM display and using the UP, DOWN, and ENTER pushbuttons, the various options can be set for each of the system settings. Refer to the following steps to change the system settings:

1. To enter Program Mode, press and hold the UP and DOWN pushbuttons for one second. 2. The display will alternate between the system setting number and the option value currently set for it. When showing the system setting number, the left digit of the display will show the system setting number (0-9) and the right digit of the display will be blank. When showing the option value both display digits are used to show the 2-digit option value. 3. Press the ENTER button while the system setting number is displayed to advance the system setting number. 4. Press the UP or DOWN button while the option value is displayed to change the option value.

✦ NOTEA unique network address (1-8) must be set before

communicating with network. The master node must be set to 1 (default). 5. Press the ENTER button while the option value is displayed to program the value into memory. 6. Press the SYSTEM RESTART button on the CPU Circuit Board. ✦ NOTE: The unit takes up to 30 seconds to reset after pressing

the SYSTEM RESTART button.

Page 18 of the Linear Telephone Entry System (AE-2000) user manual — ACTIVATE TRANSMITTER
Page 18 · click to enlarge
Page 18

AE-2000 Operation Resident Access with an Entry Code

Visitor Access with a Resident Call

PRESS THE KEY BELOW THE OR REPEATEDLY TO SCROLL THROUGH THE RESIDENT'S NAMES

- OR -

KEY IN AN ENTRY CODE AT THE SYSTEM KEYPAD OR ENTER A CODE AT A REMOTE KEYPAD

TO SCROLL THROUGH FASTER, PRESS AND HOLD THE KEY BELOW OR THEN RELEASE THE KEY WHEN THE DESIRED LETTER IS UNDERLINED

IF THE CODE IS ENTERED WRONG, PRESS THE KEY TO RESET THE KEYPAD AND RE-ENTER THE CORRECT CODE (USE THE KEY TO RESET REMOTE KEYPADS)

WITH THE RESIDENT DIRECTORY DISPLAYED, ENTER THE RESIDENT'S DIRECTORY NUMBER TO PLACE A TELEPHONE CALL TO THE RESIDENT

- OR -

IF THE SYSTEM IS DISPLAYING THE DIRECTORY NAMES, PRESS THE KEY FIRST, BEFORE KEYING IN AN ENTRY CODE

IF THE VISITOR ALREADY KNOWS THE RESIDENT'S DIRECTORY NUMBER, THEY CAN PRESS THE KEY THEN ENTER THE DIRECTORY NUMBER WITHOUT VIEWING THE DIRECTORY DISPLAY

PRESSING THE KEY DURING A TELEPHONE CALL WILL CANCEL THE CALL IN PROGRESS

  • Residents have up to 40 seconds to key in their entry code.
  • Up to eight seconds are allowed between each keystroke.
  • If the code is entered wrong, press the key to reset the keypad and re-enter the correct entry code. (On remote keypads, press the key to reset the keypad.)
  • If the system is displaying the directory names, press the key fi rst, before keying in the entry code.
  • After a correct code is entered, and if the conditions for granting access are fulfi lled, the programmed relay will activate for the programmed time.
  • If the number of incorrect codes entered exceeds the keypad lockout count, the keypad will be locked and not accept any entries for one minute.
  • If the Anti-passback feature is enabled, the entry code will be unusable until the anti-passback time expires.

VISITOR

RESIDENT

THE RESIDENT TALKS TO THE VISITOR AND CAN GRANT OR DENY ACCESS USING THEIR TELEPHONE KEYS

RELAY "A"

RELAY "B"

DISCONNECT

  • Press the key below the or arrow repeatedly to scroll through the resident’s names alphabetically and display their associated directory number.
  • To scroll through the alphabet faster and choose which letter to view, press and hold down the key below the or arrow. Release the key when the desired letter is underlined.
  • With the resident directory displayed, the visitor enters the directory number to place a call to the resident.
  • If the visitor already knows the resident’s directory number, they can press the key then enter the directory number without viewing the directory display.
  • The system will dial the resident’s telephone number to establish 2-way communications. ✦ NOTE: The resident’s telephone number will never be displayed to

Resident Access with a Wireless Transmitter

ACTIVATE TRANSMITTER

ANTENNA

  • the visitor.
  • If the resident is using the telephone at the same time a visitor calls, the system will indicate to the visitor that the line is busy.
  • The resident answers the call and converses with the visitor to determine if access will be granted.
  • The resident can use their telephone’s keypad to grant access activating Relay Channel “A” by pressing , or activating Relay Channel “B” by pressing . After access is granted, the system will disconnect the visitor and resident call.
  • The resident can disconnect the visitor without granting access by pressing or by hanging up. ✦ NOTE: The telephone keys that the resident presses can be
  • Activate a wireless transmitter within radio range of the AE-2000’s antenna.
  • After a valid transmitter is decoded, and if the conditions for granting access are fulfi lled, the programmed relay channel will activate for the programmed time.
  • If the Anti-passback feature is enabled, the transmitter will become unusable until the anti-passback time expires.

customized for the installation. • The length of time the visitor is allowed to talk can be programmed from 15-255 seconds. The resident will hear a series of beeps during the last 10 seconds of talk time. To restart the talk timer, the resident can press on their telephone.

Page 19 of the Linear Telephone Entry System (AE-2000) user manual — Dimension Drawing
Page 19 · click to enlarge
Page 19

Specifi cations

MECHANICAL Case dimensions: 15-1/4” W x 19” H x 4” D ELECTRICAL Voltage: 16-24 Volts AC or 12-24 Volts DC Current: 2000 mA @ 16 VAC maximum Backup Battery: Externally charged 12 Volt DC source, 6 amp/hr minimum Outputs: Relay Channels A-D Form “C” 3 Amps @ 30 Volts maximum Inputs: Four normally closed door sense inputs Four normally open exit request inputs Two WIEGAND reader inputs Three PBUS inputs Network: Three-wire network RADIO Frequency: 318 MHz ± 500 KHz @ 23°C Bandwidth: 300 KHz Typical Sensitivity: -97 dBm Minimum (-100 dBm Typical) Encoding: Linear MegaCode® Format ENVIRONMENTAL Temperature: -22°F to 149°F (-30°C to 65°C) Humidity: 5% to 95% non-condensing

Dimension Drawing

Linear Telephone Entry System (AE-2000) — Dimension Drawing diagram (page 19)
Fig. 22 · Dimension Drawing
Linear Telephone Entry System (AE-2000) — Dimension Drawing diagram (page 19)
Fig. 23 · Dimension Drawing
Page 20 of the Linear Telephone Entry System (AE-2000) user manual — Troubleshooting System completely dead
Page 20 · click to enlarge
Page 20

Troubleshooting System completely dead

Main or remote keypad will not activate a relay

1. Entry code is not assigned. 2. Keypad may be in lockout from too many incorrect attempts. Wait one minute for lockout to clear and try again. 3. Remote keypad wiring incorrect. Resident’s Telephone does not ring when a visitor calls
1. No power from transformer. Check voltage at transformer terminals. 2. Check voltage at AE-2000 power terminal strip. Buzz on speaker
1. Resident’s telephone number programmed incorrectly. 2. Check AE-2000 telephone line. 3. Call resident from another line or cell phone to determine if the resident’s telephone is working. Transmitter does not activate relay
1. Check for 24 volt AC power shorted to wiring conduit. 2. Check for telephone line shorted to ground. 3. Verify that telephone wires are twisted pair. 4. Verify that the AE-2000 is connected to earth ground. 5. Check 16 VAC voltage at AE-2000 transformer terminals. Buzz on telephone line
1. Transmitter button setting programmed to “none” (would effect all transmitters). 2. Transmitter not enrolled. 3. Specifi c transmitter is deactivated in the system. Poor transmitter radio range
1. Disconnect 16 VAC wires from terminal strip, if buzz goes away, one side of the transformer wires is grounded. 2. Check all connections for any shorts to ground. System will not answer an incoming call

1. Check antenna installation and condition if transmitters were previously working well. 2. Check the RADIO indicator on the AE-2000 circuit board. If it is fl ickering without activating any transmitters there is interference blocking the receiver. Try adjusting the RECEIVER RANGE knob to reduce the receiver’s sensitivity to the interference. 3. Connect an audio amplifi er or telephone buttset to the RECEIVER TEST POINTS (the wire jumpers next to the RECEIVER RANGE knob). Listen to the sounds of the signals being received. If you hear the interference, remove power from possible interfering devices to determine the source of the interference. The antenna or the interfering device may need to be relocated. 4. Use Model FT-1 to check for interference.

1. Automatic telephone answer disabled. 2. AE-2000 telephone line trouble. Entry code will not activate relay
1. Entry code not assigned. 2. Entry code not set up for proper relay. 3. Keypad is in lockout. Remote PBUS device does not work
1. Check remote device address switch setting. 2. Check remote device for power. 3. Be sure the device is wired correctly.

Linear Limited Warranty This Linear product is warranted against defects in material and workmanship for twenty-four (24) months.. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

FCC Notice Changes or modifi cations not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Copyright © 2008 Linear LLC 220231 B

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linear Telephone Entry System (AE-2000)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear Telephone Entry System (AE-2000)

Be the first to ask — other owners or our team will answer.

Original document

Linear Telephone Entry System (AE-2000) manual PDF

20 pages·1.2 MB·Home Security System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…