Contents Introduction The Model AE-2000 Telephone Entry & Access Control System is designed for use as a primary access control device for gated communities, parking garages, offi ce buildings, apartments, dormitories, hotels/motels, commercial buildings and recreational facilities. Housed in a locked, rugged stainless steel faced enclosure, the AE- 2000 features a lighted keypad with bright, easy-to-read graphics, a large backlit display with programmable welcome message, a built-in microphone, speaker, and provision for an optional color CCTV camera. The cabinet is monitored with a magnetic “tamper” switch. The four relay output channels can be programmed to control electric door strikes, magnetic locks, door & gate operators, or barrier gates. The system utilizes hands-free, full duplex telephone communications between visitors and residents for granting access. Complete access control event logging, access time restriction, access location restriction, and administration functions are also available to manage the installation. The AE-2000 is network ready. Multiple units can be interconnected on a 3-wire RS-485 network. Two Wiegand inputs are available for connection of 26, 30, or 31-bit Wiegand devices (card readers, etc.). Three sets of PBUS inputs are available for connection to Linear’s line of remote accessories.
Introduction 2 Operation 2 Hardware Features 3 Software Highlights 3 Feature Overview 3 Accessory Overview 4 PBUS Accessories 4 Wiegand Accessories 4 Component Locations 5 Wiring Diagram 6 Important Mounting Requirements 7 Entry System Mounting 8 Entry System Mounting (Continued) 9 Relay Output Wiring 10 Power, Battery, & Ground Wiring 11 RS-232 Port 11 Telephone Wiring 12 Optional Radio Antenna 12 Optional Postal Lock 13 Optional Color CCTV Camera 13 PBUS Accessories 14 Wiegand Accessories 14 Optional Network Connection 15 System Adjustments 16 System Diagnostics 16 Internal Controls 17 AE-2000 Operation 18 Specifi cations 19 Dimension Drawing 19 Troubleshooting 20 Linear Limited Warranty 20 FCC Notice 20
Operation In a typical installation, the unit’s memory would be programmed with each resident’s name and directory code number. Arriving visitors would use the keys on the AE-2000 to view the directory names and directory number for the desired resident. Upon selecting the directory number, the AE-2000 will automatically dial the resident’s telephone number and establish two-way voice communication between the visitor and the resident. The resident will then have the option to grant or deny access to the visitor by pressing a digit on their telephone. In addition to the telephone entry, the AE-2000 can grant access using entry codes at the local or remote keypads. Also remote receivers, card readers, and interior and exterior keypads can be used with the system. Block coded MegaCode® transmitters can be used to gain access through the AE-2000’s built-in or remote radio receivers. Each transmitter can be individually suspended or re-activated. The system’s clock/calendar can control access based on specifi c times and dates. Automatic relay activation can be scheduled. Access can be restricted to certain times and dates. Holiday access can be scheduled. The system’s event log records system activity for future reference.

Variable gain, high-sensitivity receiver for wireless transmitters ✓ FOUR FORM “C” (N.O. & N.C) RELAYS
Four 3-amp dry contact relay outputs are provided to activate access devices, such as door strikes, magnetic locks, automatic doors, barrier gates, and automatic sliding gates. The relay outputs can also be used as specialty outputs for alarm contact shunting, operator obstacle triggering, and alarm activation. Each of the relays can also be manually activated from buttons on the AE-2000 circuit board. LED indicators display the status of each relay.
Each relay has 3-amp @ 24-volt rating ✓ FOUR REQUEST-TO-EXIT INPUTS
Activates access device for exiting using a hardwired switch ✓ FOUR SENSING INPUTS
For sensing door position to control door-ajar and alarm features ✓ BUILT-IN ANNUNCIATOR
Each relay channel has a request-to-exit input. These inputs are supplied for hardwire activation of the access devices. Typically a request-to-exit input is wired to a pushbutton inside of the access controlled area. When a person desires to exit, pressing the pushbutton will activate the output relay channel and trigger the access device. A loop detector for automatic gate operation can be connected to a request-to-exit input.
Chirps during keystrokes ✓ BUILT-IN MODEM
No add-on modem required for telephone communications with system ✓ RS-232 PORT
COM port for direct connection to a computer ✓ NETWORK SUPPORT
Multiple units can be connected together to share data ✓ EXPANSION INTERFACE SUPPORT
The sensing inputs connect to door switches that monitor whether the controlled door is open or closed.
Model AM-MIO accessory adds additional input and outputs to the AE-2000 ✓ ON-BOARD CLOCK/CALENDAR CIRCUIT
Stamps the event log data as it is stored in the system’s memory ✓ WIEGAND INPUTS
A modular connector is provided for telephone line connection to the unit’s built-in 33.6K baud modem. The system can be accessed remotely for programming and control over the standard telephone system using a personal computer with a modem. For system backup, a computer connected through the modem can store and retrieve the AE-2000’s memory data.
Two Wiegand format card reader inputs for connection to external devices. ✓ LINEAR PBUS SUPPORT
Three PBUS input/output ports for connection of up to 6 Linear accessories. ✓ CCTV COLOR CAMERA SUPPORT
Model CCM-1 accessory camera allows color video monitoring of the keypad area ✓ POWER FAILURE MONITOR
A modular connector is provided for the bi-directional 38.4K baud RS-232 port. The AE-2000’s RS-232 port connects to a personal computer’s COM port. System programming can be performed locally with a computer connected to the RS-232 port.
AC power input is monitored, power outages are recorded in the event log
No dedicated programmer required, program with a computer and a modem ✓ LARGE ENTRY CODE CAPACITY
The local keypad is the system’s primary keypad. The local keypad activates Relay Channel “A”, but can be programmed for any of the relays.
Up to 20,000 entry codes can be used for gaining access ✓ 2-8 DIGIT ENTRY CODE LENGTH
Flexible code length for different applications ✓ LARGE RESIDENT DIRECTORY CAPACITY
The AE-2000 cabinet has provisions for installing a U.S.P.S. postal lock for keyed mail carrier access. The postal lock will activate Relay Channel “A”, but can be programmed for any of the relays.
Up to 10,000 residents ✓ 2-4 DIGIT DIRECTORY NUMBER LENGTH
Directory number lengths can be customized for small or large installations ✓ LARGE TRANSMITTER CAPACITY
Linear’s Model MGT safety edge transmitter is compatible with the AE-2000. The MGT detects and transmits obstacle events to the AE-2000.
Up to 45,600 block coded and 20,000 individually enrolled Linear transmitters can be used for gaining access ✓ TRANSMITTER FACILITY CODE SUPPORT
Identifi es wireless transmitters by installation ✓ LARGE CARD CAPACITY
The AE-2000’s fl ash memory retains all entry codes, transmitter information, card access, and programming, even without power.
Up to 45,600 block coded and 20,000 individually enrolled cards can be used for gaining access ✓ FOUR INDEPENDENT RELAY CHANNELS
The system programming can be accomplished by a computer and modem using Linear’s AccessBase2000 programming software.
Each output’s action is programmable ✓ PROGRAMMABLE TIME SCHEDULED RELAY ACTIVATION
The system supports a 12-volt battery backup or uninterruptable power supply for operation during power outage. The system does not charge the backup battery, an external battery charger is required to maintain the battery.
Activation for up to four time periods for each of the 31 system time zones ✓ PROGRAMMABLE TIME ZONE ACCESS VALIDATION
Validation during four time periods for each of the 31 system time zones ✓ PROGRAMMABLE VALIDATION DAYS
Select days of the week access is allowed ✓ PROGRAMMABLE HOLIDAY DAYS
Multiple AE-1000, AE-2000, & AM-3 units can be networked together via RS-485 allowing information sharing between the units. Networked units are interconnected with a three-wire cable. A common event log is retained for all of the networked units.
Select up to 24 expiring & 24 non-expiring holidays for access restriction ✓ OBSTACLE TRANSMITTER SUPPORT
Compatible with Linear’s Model MGT transmitter ✓ EVENT LOG
Stores up to 20,000 system events in memory for record keeping ✓ DELETED CARDHOLDER DATABASE
Three 6-wire Linear PBUS input/output ports are available to connect to several accessories (keypads, proximity readers, remote receivers). A typical application for a remote keypad or reader would be to control additional doors or gates.
System logs deleted cardholders for future identifi cation ✓ TIMED ANTI-PASSBACK
Disables entry code for a programmed time after use

Accessory Overview PBUS Accessories Several compatible accessories are available to connect to the AE-2000’s three 6-wire communications “PBUS” inputs. Up to six PBUS accessories can be used with each AE-2000 unit.
AM-RRR Remote Radio Receiver For wireless transmitters, connect the Model AM- RRR high-gain superheterodyne UHF receiver. The receiver is housed in a weather-resistant enclosure and can be mounted indoors or outdoors. Gaskets and a weather-tight wiring strain relief seal the unit from the elements. AM-RPR Radio Proximity Receiver The Model AM-RPR functions as a remote device that supplies localized radio reception for the AE-2000 In a typical installation, the AM-RPR would be mounted in a plastic single-gang electrical box next to the controlled opening. When the user requires access, their transmitter must be activated within three inches of the AM-RPR faceplate. AM-KP Exterior Keypad The Model AM-KP is housed in a rugged cast aluminum enclosure designed for exterior installations. The die-cast keys have bright, easy-to-read yellow graphics. The keypad can be mounted to a pedestal or directly to a wall. A keylock secures the keypad to the mounting backplate. AM-KPI Interior Keypad The Model AM-KPI keypad is housed in a rugged, plastic enclosure designed to be mounted indoors in a standard single-gang electrical box. Tamper resistant screws secure the keypad to its mounting plate. The die-cast keys have bright, easy-to-read yellow graphics and is illuminated with white LEDs.The keypad is supplied with a satin-chrome bezel and three interchangeable colored bezels (white, ivory, & bronze) to customize the keypad appearance for the installation. AM-CRI Card Reader Interface The Model AM-CRI expands the standard two AE-2000 Wiegand inputs by supporting one or two additional 26-bit Wiegand input devices per AM-CRI interfaces used.
REMOTE
RADIO ANTENNA
AM-RRR REMOTE
RADIO RECEIVER
AM-RRR
AE-2000 TELEPHONE ENTRY & ACCESS CONTROL
SYSTEM
AM-RPR
AM-KP
WIEGAND ACCESSORIES
PBUS ACCESSORIES
AM-KPI
AM-KPI INTERIOR
AM-WOR WIEGAND
AM-CRI
KEYPAD
OUTPUT RECEIVER
Wiegand Accessories Two Linear accessories are available to connect WIEGAND format devices to the AE-2000. Most other manufacturer’s 26, 30 & 31-bit WIEGAND output devices can also be used with the AE-2000.
WOR Wiegand Output Radio Receiver For block-coded Linear wireless transmitters, connect the Model WOR high-gain superheterodyne UHF receiver. The receiver is housed in a weather- resistant enclosure and can be mounted indoors or outdoors. Gaskets and a weather-tight wiring strain relief seal the unit from the elements. AM-PR Proximity Reader The Model AM-PR is a radio-based reader that works with either proximity tags (Model AM-PT) or proximity cards (Model AM-PC), both of which are slotted to attach to key rings. Upon reading a user’s tag or card, it transmits the entry data via a Wiegand output to the AE-2000. An integral LED confi rms to the user that access is granted.
AM-KP EXTERIOR
KEYPAD
WOR
AM-RPR
AM-CRI
RADIO PROXIMITY
CARD READER INTERFACE
RECEIVER
AM-PR
* · 0 # · *


FOR EASY WIRING, THE UNIT'S TERMINAL BLOCKS CAN BE UN-PLUGGED FROM THE CIRCUIT BOARD


THIS WIRING EXAMPLE SHOWS: DOOR ACCESS WITH A DOOR STRIKE ON RELAY CHANNEL "A" DOOR ACCESS WITH A MAGNETIC LOCK ON RELAY CHANNEL "B" GATE ACCESS WITH A GATE OPERATOR ON RELAY CHANNEL "C" (YOUR INSTALLATION MAY VARY)

Mounting Environment Consider the environmental factors at the desired mounting location. The AE-2000 is designed for direct outdoor installations, however, it is preferable to protect the unit from extreme exposure to sun, driving rain, or snow whenever possible. Mounting the unit in a kiosk can provide extra environmental protection.
Follow Building Codes Check all local building codes and ordinances prior to installing the system. Proper installation of the AE-2000 conforming to the local building codes for access control equipment is a regulatory requirement. The AE-2000 installation is an extremely important and integral part of the overall access control system.

Mounting Location If the AE-2000 is used to control a door or pedestrian gate, locate the unit as near as practical to the entry point. If the unit is mounted on or in a wall adjacent to the entry point, be sure the wall is sturdy. The repeated shock and vibration from a slamming access door or spring-loaded pedestrian gate must be isolated from the AE-2000. NEVER MOUNT THE UNIT DIRECTLY TO A MOVING DOOR OR GATE!

Gate Installations If the AE-2000 is used to control a gate operator connected to a vehicular gate, the unit MUST be mounted AT LEAST 10 feet away from the gate (open and closed) and gate operator. AT NO TIME SHOULD A PERSON BE ABLE TO TOUCH THE GATE OR GATE OPERATOR AND THE AE-2000 AT THE SAME TIME.
Vehicle Traffi c Do not mount the AE-2000 where it extends into any traffi c lane. Locate the gooseneck pedestal or entry kiosk so all parts of the AE-2000 are outside the traffi c lane. Locate the AE-2000 clear of any turn-around lanes vehicles use when access is denied.
Americans with Disability Act (A.D.A.) Requirements THE FOLLOWING WHEELCHAIR ACCESS REQUIREMENTS ARE FOR PUBLIC DOOR CONTROL INSTALLATIONS ONLY.
1. If the clear fl oor space allows only forward approach to the system, the maximum high forward reach allowed is 48” above grade to the top of the keypad. 2. If the high forward reach to the system is over an obstruction of greater than 20” but less than 25”, the maximum high forward reach allowed is 44” above grade to the top of the keypad. 3. If the clear fl oor space allows parallel approach by a person in a wheelchair, the maximum high side reach shall be 54” above grade to the top of the keypad. 4. If the high side reach is over an obstruction of 24” or less, the maximum high side reach allowed is 46” above grade to the top of the keypad.

Entry System Mounting The AE-2000 cabinet is designed to be mounted three ways:

LOOSEN THE TOP TWO NUTS & REMOVE THE BOTTOM TWO NUTS
Opening and Closing the Cabinet The AE-2000’s cabinet hinges are spring loaded to help weather seal the cabinet. To open the cabinet, press the cabinet door fi rmly around each lock while turning each key counterclockwise. To close the cabinet, press the cabinet door fi rmly around each lock while turning each key clockwise.
CAREFULLY REMOVE THE FIVE WIRING HARNESS CONNECTORS & GROUND WIRE
Mounting Preparation Before mounting the system, the main circuit board mounting plate must be removed to provide access for the wiring hole and mounting fasteners.

Surface Mounting The cabinet can be mounted on a wall or any suitable fl at surface. The four 3/8” mounting holes or the four self-drill locations can be used to attach the cabinet to the surface.
1. For wall mounting, hold the cabinet at the approximate mounting location where the display will be about eye level or slightly above. 2A. If using the 3/8” mounting holes, mark the four mounting hole centers. Drill as required. Use the appropriate fasteners for the mounting surface to secure the cabinet. 2B. If using the self-drill mounting holes, choose the correct size bit for the fasteners and drill the cabinet as required. Use the appropriate fasteners for the mounting surface to secure the cabinet. 3. After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire.
ATTACH THE CABINET WITH APPROPRIATE HARDWARE FOR THE MOUNTING SURFACE

Entry System Mounting (Continued) Recessed Mounting The cabinet can be mounted recessed using the accessory trim-ring (P/N ACP00914). The trim-ring mounts in the wall and the cabinet attaches to the trim-ring.

DETERMINE LOCATION FOR THE 15-½" x 19" MOUNTING HOLE
1. Identify the location of any studs in the wall. 2. Cut a 15-½” wide by 19” high rectangular hole between studs at the mounting location. 3. Install any additional mounting material required to provide surfaces inside the wall 15-½” apart for attaching the trim-ring. 4. Place the trim-ring in the wall hole. Check for level, then attach the trim-ring with up to six screws into the side tabs. 5. Drill the cabinet’s six self-drill mounting holes the appropriate size for the hardware. 6. Attach the cabinet to the trim-ring using self-tapping screws. 7. After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire.
4 INSTALL ANY SHIMS TO ALLOW MOUNTING AND ATTACH THE TRIM-RING WITH UP TO 6 SCREWS
DRILL 3/16" HOLES IN THE CABINET AT THE PRE-MARKED LOCATIONS
ATTACH THE CABINET TO THE TRIM-RING WITH SELF-TAPING SCREWS
Pedestal Mounting The cabinet can be mounted on a gooseneck pedestal. Linear manufacturers two pedestals: Model GNC-1 is for surface mounting with concrete fasteners, Model GNB-1 is for burial mounting. When mounting to a pedestal, use the cabinet reinforcing plate to stiffen the cabinet.

ALIGN THE REINFORCING PLATE ON THE INSIDE OF THE CABINET
USE SECURITY HARDWARE TO ATTACH THE PLATE AND CABINET TO THE PEDESTAL

Relay Output Wiring Any of the four relay outputs channels (A-D) can be used to control access devices on doors or gates.
RELAY TERMINALS
ELECTRIC
GND DS N.O. COM N.C.
Door or Pedestrian Gate Control
1. Install a low voltage electric door strike or magnetic lock as a locking device for the door or pedestrian gate. 2. Install the power supply or transformer for the locking device. DO NOT POWER THE AE-2000 FROM THIS POWER SUPPLY. 3. Connect one wire from the power supply to one wire from the locking device. 4. Route two wires between the locking device and the AE-2000. Connect one wire to the remaining wire of the locking device. Connect the other wire to the remaining wire of the power supply. 5A. For a door strike, connect the wires to the AE-2000 relay COM & N.O. terminals. 5B. For a magnetic lock, connect the wires to the AE-2000 relay COM & N.C. terminals. Gate Control
RTE
TYPICAL MAGNETIC LOCK HOOKUP
MAGNETIC
GND DS N.O. COM N.C.
LOCK
DOOR
LOCK POWER SUPPLY
RTE
GND DS N.O. COM N.C.
wiring diagram.
Request-to-Exit Inputs Each of the four relay outputs has a request-to-exit input terminal. Grounding this terminal will activate the associated relay. Exit request inputs are typically used with push bars, loop sensors, or pushbuttons.


AC2
AC1
DC
DC
EARTH GROUND
STUD
EARTH GROUND
STAKE 12 VOLT BATTERY
NOTE: THE OPTIONAL
BACKUP BATTERY
clock/calendar and programming memory during power outages. 1. Route two wires between the AE-2000 and the backup battery. 2. Connect the Battery positive to the AE-2000 DC+ terminal and the negative to the DC- terminal. ✦ NOTE: The AE-2000 does not supply battery charging current.
An external battery charger will be required to maintain the battery.
Earth Ground For the best ground, use size 12 gauge solid wire or larger to connect to an 8-foot copper ground rod. Locate the ground rod next to the Power and Telephone company rods and bond the rods together with a new clamp. Do not disturb the clamps installed by the Power or Telephone Company. Alternately, connect to a metallic cold water pipe for the earth ground.
COMPUTER'S
COM PORT
SET COMPUTER COM PORT
LINEAR MODEL A2C SERIAL COMPUTER CABLE
BAUD RATE TO 38,400 BPS

Telephone Wiring For telephone entry and programming, the AE-2000 connects to a standard telephone line.

1A. If using the AE-2000 modular connector for the telephone connection, connect a double-ended modular cable between the AE-2000’s PHONE jack and the modular telephone jack wired to the installation’s telephone line. 1B. If using the AE-2000 terminal block for the telephone connection, connect the “ring” wire (usually red) to the RING terminal, connect the “tip” wire (usually green) to the TIP terminal.
Optional Radio Antenna If wireless transmitters are going to be used in the system a remote antenna must be installed to provide reception for the AE-2000. A basic antenna kit is supplied with the AE-2000. The kit contains a whip antenna, connector, and a 36” length of coax cable. The antenna connector should be mounted on a metal surface using a 3/8” hole. Two other models of antennas are compatible with the AE-2000. The Model EXA-1000 is a non-directional antenna. The Model EXA-2000 is a directional antenna used in installations where transmitted signals are desired to be received only in a particular direction.

the antenna to the AE-2000. Keep the coax as short as possible. 1. Install the antenna. (See installation instructions if using the EXA-1000 or EXA-2000.) 2. Connect the antenna coax cable to the antenna and route the cable to the AE-2000. 3. Connect the cable to the AE-2000’s ANTENNA connector. Receiver Range Control The AE-2000 has a RECEIVER RANGE adjustment knob. In some installations, it may be necessary to reduce the effective radio range of the receiver to limit the distance that transmitters can be used. Reducing the radio’s sensitivity may also help in installations where unwanted interference is overpowering signals from transmitters.

Optional Postal Lock A postal lock can be installed in the AE-2000 Entry System to provide keyed access for the postal service. The AE-2000 case is designed to accept a U.S. Postal Service postal lock. When the postal lock is engaged, the programmed output relay will activate.

1. After opening the cabinet, re-lock the left cabinet lock to provide clearance to remove the postal lock switch plate. 2. Remove the four locknuts that retain the postal lock switch plate, hole cover plate, and block (below the left cabinet lock on the AE-2000 faceplate). The hole cover plate and block will not be used and can be discarded. 3. Remove the switch plate from the four studs. 4. Install the postal lock assembly onto the four studs. The postal lock’s moving plunger should point down (see fi gure). 5. Replace the postal lock switch plate with the microswitch oriented toward the front of the cabinet where it will be pressed by the postal lock’s moving plunger (see fi gure). 6. Secure the postal lock and switch plate with the four locknuts. ✦ NOTE: Be sure the postal lock’s plunger actuates the
REPLACE PLATE WITH THE MICROSWITCH TOWARDS THE FRONT OF THE CABINET, REPLACE LOCKNUTS
microswitch. Adjust the switch plate and the postal lock then test the action until the microswitch fully actuates. 7. Tighten the four locknuts after the adjustment and testing is complete. 8. When programming the system, set the postal lock option to activate the desired relay output.
Optional Color CCTV Camera Linear’s Model CCM-1 (P/N ACP00904) CCTV camera can be installed inside the AE-2000 Entry System. The camera provides a video signal for viewing the area in front of the entry system. The CAMERA connector is used to connect the camera to the AE-2000. The 4-conductor cable routes power to, and video from the camera. The VIDEO jack is the camera output for connection to a video cable with a Type “BNC” connector. Up to 400 feet of 75-ohm RG-59 video cable can be used. Longer cable runs may require the use of a video amplifi er.

1. Remove the two plate locknuts from the camera mounting studs above the right keylock on the AE-2000 faceplate. 2. Remove the cover plate. 3. Remove the protective backing from the plastic window included with the camera and install the plastic window onto the studs with the adhesive side against the door. 4. Remove the lens cap from the camera. 5. Mount the camera assembly on the two studs, with the alignment hole in the camera bracket towards the top. Secure the camera with the two locknuts. 6. Connect the camera’s cable to the AE-2000’s CAMERA connector. 7. Connect the video cable to the AE-2000’s VIDEO connector. 8. Connect the other end of the video cable to the viewing monitor or the video distribution system.
REMOVE PROTECTIVE BACKING AND APPLY WINDOW WITH ADHESIVE SIDE AGAINST DOOR
ATTACH CAMERA WITH TWO NUTS CONNECT CAMERA WIRING HARNESS
Postal Lock Installation · Camera Installation

PBUS Accessories Six accessories (keypads, proximity readers, remote receivers) can be connected to the AE-2000’s three PBUS input/output ports. A typical application for a remote keypad would be to control a second door or gate. Linear’s PBUS devices compatible with the AE-2000 are:

SET THE REMOTE DEVICE ADDRESS SWITCH TO A UNIQUE DEVICE ADDRESS
Wiegand Accessories The two AE-2000 Wiegand inputs (WIEGAND A & B) can connect to a large variety of 26, 30, and 31-bit Wiegand output accessories. The Wiegand format is a common standard for access control equipment. A typical application would be to add swipe card or proximity readers to the system.


Optional Network Connection Linear’s AE-1000, AE-2000, & AM-3 Access Control Systems can be connected together in a network. A network will allow sharing programming and user information between the systems. Network wiring conforms to 3-wire RS-485 electrical specifi cations. Units connected in the network can be wired using one unit as a “hub” or by wiring from one unit to the next in “daisy-chain” fashion. See the fi gures for wiring options.

ACCESS CONTROL HOMERUN NETWORK USING ONE UNIT AS A NETWORK MASTER
terminals.

Network with Hub

System Adjustments The factory settings are suffi cient for most installations. The system can be adjusted to customize the installation.

System Volume Adjustment The sound level of the synthesized voice and key beep can be adjusted.
Display Contrast Adjustment If the lighting in the area or the viewing angle of the display in the installation causes the display to look too dark or too light, the display’s contrast can be adjusted.
1. Press the 1, 5 & 9 keys at the same time. The system will assume Contrast Adjustment Mode for 15 seconds. 2. Press the up and down arrow keys until display has the best visibility. 3. Press the or key to exit Contrast Adjustment Mode. System Diagnostics Several components on the main circuit board are for monitoring the system during operation. When calling for technical assistance, Linear’s Technical Services Department may ask the installer to use these components to diagnose the system.
HOST ON-LINE
DISPLAY
ACCESS GRANTED
VALIDATE
DECODE
On-board Indicators 17 LED indicators are on the main circuit board. Refer to the fi gure for the location of each indicator.
RELAY "A"
ACTIVE
RELAY "B"
READER "B"
ACTIVE
AE-2000 MAIN CIRCUIT BOARD
PBUS
RELAY "C"
ACTIVE
RELAY "D"
NETWORK
ACTIVE
POWER OFF HOOK TALK

Internal Controls On-board Pushbuttons Seven pushbuttons are on the main circuit board. Refer to the fi gure for the location of each pushbutton.

On-board Display The STATUS/PROGRAM display will show system conditions and can be used to aid system setup.
Status Mode While the system is running, the display will show the current system status. Normally the left digit will show a moving pattern and the right digit will show the unit’s Network Node number. When a supervisory condition exists, the display will cycle to show the condition(s). When an item is displayed, press the ENTER button to clear the display (clears the display only, the condition may still exist). Refer to the following table for the supervisory condition display codes.

Program Mode Options for up to ten system settings can be controlled in Program Mode. By viewing the STATUS/PROGRAM display and using the UP, DOWN, and ENTER pushbuttons, the various options can be set for each of the system settings. Refer to the following steps to change the system settings:
1. To enter Program Mode, press and hold the UP and DOWN pushbuttons for one second. 2. The display will alternate between the system setting number and the option value currently set for it. When showing the system setting number, the left digit of the display will show the system setting number (0-9) and the right digit of the display will be blank. When showing the option value both display digits are used to show the 2-digit option value. 3. Press the ENTER button while the system setting number is displayed to advance the system setting number. 4. Press the UP or DOWN button while the option value is displayed to change the option value.
communicating with network. The master node must be set to 1 (default). 5. Press the ENTER button while the option value is displayed to program the value into memory. 6. Press the SYSTEM RESTART button on the CPU Circuit Board. ✦ NOTE: The unit takes up to 30 seconds to reset after pressing
the SYSTEM RESTART button.

Visitor Access with a Resident Call
PRESS THE KEY BELOW THE OR REPEATEDLY TO SCROLL THROUGH THE RESIDENT'S NAMES
KEY IN AN ENTRY CODE AT THE SYSTEM KEYPAD OR ENTER A CODE AT A REMOTE KEYPAD
TO SCROLL THROUGH FASTER, PRESS AND HOLD THE KEY BELOW OR THEN RELEASE THE KEY WHEN THE DESIRED LETTER IS UNDERLINED
IF THE CODE IS ENTERED WRONG, PRESS THE KEY TO RESET THE KEYPAD AND RE-ENTER THE CORRECT CODE (USE THE KEY TO RESET REMOTE KEYPADS)
WITH THE RESIDENT DIRECTORY DISPLAYED, ENTER THE RESIDENT'S DIRECTORY NUMBER TO PLACE A TELEPHONE CALL TO THE RESIDENT
IF THE SYSTEM IS DISPLAYING THE DIRECTORY NAMES, PRESS THE KEY FIRST, BEFORE KEYING IN AN ENTRY CODE
IF THE VISITOR ALREADY KNOWS THE RESIDENT'S DIRECTORY NUMBER, THEY CAN PRESS THE KEY THEN ENTER THE DIRECTORY NUMBER WITHOUT VIEWING THE DIRECTORY DISPLAY
PRESSING THE KEY DURING A TELEPHONE CALL WILL CANCEL THE CALL IN PROGRESS
RESIDENT
THE RESIDENT TALKS TO THE VISITOR AND CAN GRANT OR DENY ACCESS USING THEIR TELEPHONE KEYS
RELAY "B"
DISCONNECT
Resident Access with a Wireless Transmitter
ANTENNA
customized for the installation. • The length of time the visitor is allowed to talk can be programmed from 15-255 seconds. The resident will hear a series of beeps during the last 10 seconds of talk time. To restart the talk timer, the resident can press on their telephone.

MECHANICAL Case dimensions: 15-1/4” W x 19” H x 4” D ELECTRICAL Voltage: 16-24 Volts AC or 12-24 Volts DC Current: 2000 mA @ 16 VAC maximum Backup Battery: Externally charged 12 Volt DC source, 6 amp/hr minimum Outputs: Relay Channels A-D Form “C” 3 Amps @ 30 Volts maximum Inputs: Four normally closed door sense inputs Four normally open exit request inputs Two WIEGAND reader inputs Three PBUS inputs Network: Three-wire network RADIO Frequency: 318 MHz ± 500 KHz @ 23°C Bandwidth: 300 KHz Typical Sensitivity: -97 dBm Minimum (-100 dBm Typical) Encoding: Linear MegaCode® Format ENVIRONMENTAL Temperature: -22°F to 149°F (-30°C to 65°C) Humidity: 5% to 95% non-condensing



Main or remote keypad will not activate a relay
1. Check antenna installation and condition if transmitters were previously working well. 2. Check the RADIO indicator on the AE-2000 circuit board. If it is fl ickering without activating any transmitters there is interference blocking the receiver. Try adjusting the RECEIVER RANGE knob to reduce the receiver’s sensitivity to the interference. 3. Connect an audio amplifi er or telephone buttset to the RECEIVER TEST POINTS (the wire jumpers next to the RECEIVER RANGE knob). Listen to the sounds of the signals being received. If you hear the interference, remove power from possible interfering devices to determine the source of the interference. The antenna or the interfering device may need to be relocated. 4. Use Model FT-1 to check for interference.
Linear Limited Warranty This Linear product is warranted against defects in material and workmanship for twenty-four (24) months.. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
FCC Notice Changes or modifi cations not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Copyright © 2008 Linear LLC 220231 B
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.