SUPERVISED WIRELESS SECURITY CONTROL PANEL


USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340

CONGRATULATIONS for selecting Linear's DUAL 824 Security System. The Model DUAL 824P Control Panel and the Model DUAL 824KP Keypad incorporate many advanced and sophisticated features. The system can be expanded and customized to fi t the installation's specifi c needs. The DUAL 824P Control Panel and its accessories are designed and manufactured by the oldest wireless security company in North America. You can look ahead to many years of reliable service with this Control Panel and its accessories. Many insurance companies offer discounts on homeowners and renters policies when a security system is installed. Discount credits vary with different companies and generally increase in savings with an increase in the level of protection. Inform the user to ask their insurance agent about savings available. The DUAL 824P Control Panel is UL Listed. For a UL smoke alarm system, there must be at least one smoke detector programmed into the Control Panel to meet National Fire Protection Association (NFPA) Rule 72 Chapter 2 and UL 217 requirements. Many insurance companies require these conditions to be met to qualify for a discount. Only use the Model DXS-73 smoke detector with this Control Panel for a UL smoke alarm system. NOTE: Some cities and municipalities may require an alarm system permit. Check with the local authorities before installing this system. In this manual, the bullets preceding the text help to defi ne the information. For example:

KEYPAD MODEL DUAL 824KP
UL Listed as a Single Station Smoke Detector Accessory, also suitable as a Household Burglar- Alarm System Control Unit. UL Category CCN UTGT & NBSX
✦ This symbol indicates a feature. ✴ This symbol is for lit indications or system
sounds. ✎ This symbol is for important notes.
LINEAR LLC RESIDENTIAL SECURITY RECEIVER MODEL: DUAL 824 PART # SSC00056 FREQUENCY: 315 MHz POWER SUPPLY: 16 VAC, 1.25A
WARNING:
CAUTION: IMPORTANT:
ANTENNA
TELEPHONE
To internal antenna wires or to Model LA-P external antenna kit
RING
SHIELD
GREEN
TIP
BACKUP BATTERY
This device complies with FCC Part 15 and IC Canada Rules and Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Complies with Part 68, FCC Rules. FCC Registration Number: EF4HKG-31823-AL-E Ringer Equivalence Number: 1.7B
RED (+)
CONNECT TO 12 VDC/4AH GEL CELL BATTERY
R1
Fire protection must follow NFPA Standard No. 72 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Printed information describing proper installation, operation, testing, maintenance, evacuation planning, and repair service is to be provided with this equipment.
BLACK (-)
T1
life should exceed 3 years
BATTERY FUSE TYPE 2AG, 3 AMP
HARDWIRED LOOP INPUTS OUTPUTS KEYPAD XFRMR
LOOP
1 COM LOOP
2 LOOP
3 COM LOOP
4 LOOP
5 COM LOOP
6 LOOP
7 COM LOOP
8 H/A
H/A
RLY COM
RLY
RLY
+12 VDC
KPD
KPD
KPD CLK
KPD DAT
KPD SPK+
KPD SPK -
AC AC
N/C
N/O
CANADIAN REGULATORY INFORMATION
IC ID 1078-102-556A Complies with IC RSS 210 En conformité avec IC CNR 210.
LOOP 2
LOOP 3
LOOP 4
LOOP 5
LOOP 6
LOOP 7
LOOP 8
ORANGE
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
ALARM RELAY Rated 12 volts, 1 amp maximum
RED
BLACK
WHITE
AUTOMATION
POWER OUTPUT 12 VDC at 1 Amp maximum
MODEL RSM-2 VOICE RESPONSE
EXTERNAL SIREN
switched +12 VDC, 40 mA
12 VDC at 1 Amp maximum
SPEAKER 8 Ohm - 2 Watts
N.O. N.O.
N.O. N.O.
N.O. N.O.
N.O. N.O.
16VAC, 1.25A Connect to 24hr. 120VAC, 60 Hz Outlet
Warranty Expiration Date:
See instructions for output options
KEYPAD WIRING 4-conductor 22 AWG wire Up to 100 feet for all keypads used allowed
2.2k E.O.L. RESISTOR
2.2k E.O.L. RESISTOR
2.2k E.O.L. RESISTOR
2.2k E.O.L. RESISTOR
2.2k E.O.L. RESISTOR
2.2k E.O.L. RESISTOR
2.2k E.O.L. RESISTOR
2.2k E.O.L. RESISTOR
FOR INSTALLATION INSTRUCTIONS, REFER TO THE MANUAL SUPPLIED WITH THIS PRODUCT
To any COM terminal
(760) 438-7000 • FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123
DUAL 824 WIRING DIAGRAM
Toll Free FAX (800) 468-1340




DXS-91 GLASS BREAK DETECTOR †
DXS-54
PIR
DXS-81 BILL TRAP †
CONTROL
DXS-31 DOOR/WINDOW
DXS-32 MINI DOOR/WINDOW
DXT-41 & DXT-42
DXS-62A REMOTE
DXT-61A REMOTE †
DXT-21 & DXT-23
REMOTES
REMOTES †
are not listed by UL.
SENSOR
CONTROL PANEL The DUAL 824P Control Panel is the heart of the system. It monitors all of the system's wireless sensors, hardwired loops, and controls the alarm sirens and Model DUAL 824KP hardwired keypads. The Control Panel constantly monitors the condition of the system's sensors and hardwired contacts, displaying which protected doors and windows are open or closed. If an alarm occurs, the keypads display which sensor(s) caused it. When a sensor has a low battery, the keypads display which sensor needs a new battery. Sensors that send hourly status transmissions keep the Control Panel informed of their operating condition. Up to eight different custom user codes can be used to operate the system. For security, a user code must be entered to disarm (turn off) the system. The system can be armed (turned on) by entering a user code, or with the unique “Quick Arm” feature. The fi ve restricted user codes and the special page alert user code can only arm and disarm the system, no programming changes (except changing user and duress codes) are allowed. The master user code is allowed to program the Control Panel, and a duress code can be selected for emergency disarming of the system with a duress report to the Central Station. The page alert user code can dial a pager number to inform the pager wearer when the system is disarmed. The Control Panel's memory will retain the user codes and all of the system's programming, even during a total power loss. An optional backup battery can be installed to power the system during short power failures. The built-in digital communicator connects the Control Panel to a Central Alarm Monitoring Station through the telephone. With a monitored system, the central station can dispatch authorities in case of burglary, fi re or other emergency. The central station can also call family, friends, neighbors, or anyone else designated on a custom call list. System arming (closing) and disarming (opening) reports by user can also be sent. Each sensor can report directly to the Central Station using the digital communicator's Point ID feature. If a sensor triggers an alarm or experiences supervisory trouble, a unique report code can be sent for immediate identifi cation of the event.
The optional Model VB-2 digital voice response module can be installed in the Control Panel. The VB-2 module provides three exciting features: 2-way audio monitoring capability at the Central Station through the communicator, local voice prompts from the keypad's speaker (with Model RSM-2 speaker/microphone kit installed), and voice prompted remote system control using in-house or off-site pushbutton telephones. The system has 24-hour capabilities that are always ready to operate, even when the system is disarmed. They can be triggered by buttons on the hardwired keypads, a wireless keypad, portable remote controls, carbon monoxide detectors, and smoke detectors. Pressing the EMERGENCY or FIRE button for two seconds will cause an immediate siren and call the central station. IMPORTANT: For personal emergency use only. Not for use as a UL Listed Medical Alert System. The Control Panel's Environmental feature is active 24-hours and can be triggered with sensors connected to devices such as water fl ow detectors, over/under temperature sensors, fl ood sensors, etc. The Environmental feature activates the chime annunciator without sounding the siren. The Environmental feature does not send communicator reports. An Automation Output in the Control Panel provides an easy way to connect external devices to the Control Panel. The output is fully programmable to activate on a variety of conditions, such as when the system is armed, during alarms, and during exit/entry delays. The Automation Output can connect to lighting control modules, relays, noisemakers, and indicators. The Control Panel's and wireless keypad's
key and any system sensors can control the Automation Output. The Control Panel can be programmed locally using its own keypad or remotely, over the telephone, using Linear's Model RA-2400 Remote Access software program. The RA-2400 upload/download program is a Windows™ application that runs on a personal computer and communicates with the Control Panel through a modem, connected directly to the panel, or through the telephone line.

DOOR/WINDOW SENSORS The DXS-31 and DXS-32 sensors monitor doors and windows. They send radio signals to the Control Panel. One type of signal is sent when the door or window is opened, and a different type of signal is sent when the door or window is closed. If the system is armed, a sensor can trigger the Control Panel's burglary siren when its door or window is opened. Both sensors are supervised, send hourly status reports, and monitor their battery condition.
PANIC BUTTONS The DXT-21, DXS-21 single-button, and DXT-23, DXS-23 two-button transmitters can be used as portable “panic buttons”. Pressing the front or top button on the DXT-21 or DXS-21 at any time will trigger the emergency siren. Pressing both front buttons simultaneously on the DXT-23 or DXS-23 at any time will trigger the emergency siren. These transmitters can be programmed to activate various other system functions. The DXT-21 and DXT-23 transmitters are not supervised. The DXS-21 and DXS-23 transmitters are supervised. The DXS-62A transmitter is typically used as a portable “panic button”. Pressing the button on a DXS-62A at any time will trigger the emergency siren. This transmitter can send hourly status signals and low battery signals if the battery is low.

WIRELESS KEYPAD The DXS-10 wireless keypad is used to operate the system remotely. It can be placed in a convenient spot so the user doesn't have to go to the hardwired keypad to operate the system. The wireless keypad can also trigger the emergency or fi re siren and actuate the Automation Output. Pressing will cause the hardwired keypad(s) to sound Beeps corresponding to the current operating mode. The DXS-10 is supervised, it sends hourly status reports and monitors its battery condition. IMPORTANT: For personal emergency use only. Not for use as a UL Listed Medical Alert System.
BILL TRAP The DXS-81 bill trap can be used with the Control Panel in non- UL small commercial hold-up installations. The unit is concealed in a cash drawer under a stack of currency, with a single “bait” bill secured in its money clip. During a hold-up, the cashier removes the stack of currency along with the “bait” bill. When a “bait” bill is removed, the transmitter sends a signal to the Control Panel. Four additional signals are sent within the fi rst minute after the “bait” bill is removed. When the “bait” bill is replaced, a restore signal is sent. The DXS-81 is supervised, it can send hourly status reports (optional) and monitors its battery condition.

SMOKE DETECTOR The DXS-73 is a high quality smoke detector with a built-in radio transmitter. As soon as smoke is detected, the unit will sound its local noisemaker. Then, 20 seconds after the local noisemaker sounds, the transmitter sends an alarm signal to the Control Panel. The alarm signal will be repeated every 20 seconds as long as smoke is still present. A restoral signal will be sent when the smoke detection chamber clears. The DXS-73 is supervised, it sends hourly status reports, and monitors its battery condition.
PASSIVE INFRARED MOTION DETECTOR The DXS-54 is a passive infrared (PIR) motion detector with a built-in radio transmitter. The PIR detects motion in its detection pattern by measuring the infrared emission levels of objects that it “sees”. If the infrared levels change quickly, as when a person moves across the detection pattern, the PIR will recognize the change as an intrusion and send an alarm signal to the Control Panel. An alarm will be triggered if the system is in the Away Mode. The DXS-54 is supervised, it sends hourly status reports and monitors its battery condition.
☞ NOTE: A Model DXS-73 Smoke Detector is required to create a UL Listed smoke alarm system. See Page 26 for details on adding a smoke detector sensor to the system.
REMOTE CONTROLS The DXT-41, DXT-61 single-button and DXT-23, DXT-42 multi-button remote controls can be used to remotely arm and disarm the system. The DXT-42’s left button will arm and the right button will disarm the system. Pressing both buttons simultaneously will trigger the emergency siren. Alternately the Control Panel can be programmed to respond to the DXT-42 by arming and disarming with the left button, and activating the automation output with the right button. These transmitters can also be programmed to activate various other Control Panel zones. These transmitters are not supervised.
DXT-41
DXT-42
DXT-61‡
GLASS BREAK DETECTOR The DXS-91 is a glass break detector with an audio sound discriminator and a built-in radio transmitter. The unit “listens” for the sound of breaking glass. When glass breakage is detected, the unit sends an alarm signal to the Control Panel. The DXS-91 is supervised, it sends hourly status reports and monitors its battery condition.

✦ The example shows a typical DUAL 824 system. ✦ Any or all of the accessories shown can be used. ✦ A total of 24 sensors can be used with each
Control Panel. Each wireless sensor, hardwired loop, and wireless keypad used occupies a sensor location.

CP - CONTROL PANEL HK - HARDWIRED KEYPAD S - DOOR/WINDOW SENSOR WK - WIRELESS KEYPAD MD - MOTION DETECTOR ES - EXTERNAL SIREN SD - SMOKE DETECTOR CO - CARBON MONOXIDE DETECTOR GB - GLASS BREAK SENSOR MS - HARDWIRED MAGNETIC SWITCH
Example Residential Security System Floor Plan

✦ One or two hardwired keypads can be used for
controlling the system. ✦ Three system status indicators:
READY, ARMED, & TROUBLE ✦ Three system supervisory indicators:
POWER, BATTERIES, & RADIO ✦ Five system mode indicators:
KEYPAD
OFF, CHIME, HOME, AWAY & TEST ✦ 24 system sensor indicators. ✦ Location inside beauty cover for supplied sensor
identifi cation labels. ✦ Press to activate the automation output. ✦ Pressing clears the keypad. ✦ Pressing for two seconds sounds the mode Beeps from the hardwired keypad(s).
✔ Off Mode: 1 “Gong”. ✔ Chime Mode: 1 “Gong” & 1 “Beep”. ✔ Home Mode: 1 “Gong” & 2 “Beeps”. ✔ Away Mode: 1 “Gong” & 3 “Beeps”. ✔ Test Mode: 1 “Gong” & 4 “Beeps”. ✦ Emergency and fi re alarm can be triggered from
the keypad at any time. ✎ UL NOTE: For personal emergency use only. Not

for use as a UL Listed Medical Alert System.
✦ For controlling the system remotely. ✦ Green operation light. ✦ Internal 9-volt battery is monitored by the Control
Panel. ✦ Keypad's beeper will buzz during transmissions
when the battery is low. ✦ Up to 3 years battery life (depends on frequency
of activation). (UL tested for 1 year minimum.) ✦ Sends hourly status reports to the Control Panel. ✦ Press to activate the automation output. ✦ Pressing clears the keypad. ✦ Pressing for two seconds sounds the mode Beeps from the hardwired keypad(s).
ABOUT SENSOR STATUS SUPERVISION All DXS Format sensors transmit hourly status reports. All DXT Format sensors do not transmit hourly status reports. Both sensor formats can be used with the system. When a sensor is programmed into the Control Panel, the system will set the sensor as non-supervised or supervised. Sensors set as non-supervised are not expected to send hourly status reports. Sensors set as supervised are expected to send hourly status reports. If a status report is not received in 8 hours from a sensor set as supervised, the RADIO indicator will fl ash. When sensors are programmed into the Control Panel, ALL STATIONARY SENSORS ARE SET AS SUPERVISED, ALL PORTABLE SENSORS ARE SET AS NON-SUPERVISED. If stationary DXT Format sensors have been programmed into the Control Panel, be sure to change their setting to non-supervised to prevent RADIO indications. This will not prevent low battery monitoring. If portable DXS Format sensors have been programmed into the Control Panel, and the installation requires supervision for specifi c portable sensor(s), change the selected portable sensors setting to supervised. After programming the sensors, if changes are required, refer to “Changing a Sensors Supervision” on Page 30 for details on changing the way a sensor’s supervision is set.
✔ Off Mode: 1 “Gong”. ✔ Chime Mode: 1 “Gong” & 1 “Beep”. ✔ Home Mode: 1 “Gong” & 2 “Beeps”. ✔ Away Mode: 1 “Gong” & 3 “Beeps”. ✔ Test Mode: 1 “Gong” & 4 “Beeps”. ✦ Emergency and fi re alarm can be triggered from
the wireless keypad at any time. ✎ UL NOTE: For personal emergency use only. Not
for use as a UL Listed Medical Alert System.


★ Blacked-out sensor status indicators are only visible when lit. ★ Indicate the status of each of the system's wireless sensors and hardwired
loops. ★ Indicators show which doors and windows are open. ★ Indicators fl ash to display sensors that have caused an alarm. ★ Stick-on labels are provided to identify the custom sensor locations.
★ Shows the current status of the system.
★ Lights when all system sensors are closed. ★ Shows that the system is ready to be armed. ★ The system can be armed without the READY indicator being lit, if sensors are
bypassed either manually or automatically.
★ Blinks during the exit delay. ★ Lights when the system is fully armed.
★ Lights when the system has detected supervisory trouble. ★ Supervisory trouble can be caused by power, sensor low battery, or sensor radio
supervision conditions. ★ Press for one second then view the system supervisory and status indicators to determine the origin of the trouble.
★ The beauty cover snaps open and shut to hide the keypad’s keys, mode and
★ Used to operate the system.
supervisory indicators, and the sensor location labeling area.
2 KEYPAD
★ Backlit keys for easy viewing in low light conditions. ★ For entering the user's user code (numerically or alphabetically). ★ Used when programming system options. ★ Press to activate the Automation Output. ★ Press to clear keypad if the wrong key is pressed. ★ Press for two seconds to view sensor battery and supervisory status (see BATTERIES and RADIO indicator description).
★ Off Mode disarms the system. ★ Switching to Off Mode stops the alarm siren.
✓ Multiple Beeps sound and sensor status indicators fl ash if an alarm has
occurred. ☞ Multiple Beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.
★ Chime Mode disarms the system. ★ Switching to Chime Mode stops the alarm siren.
3 24-HOUR BUTTONS ★ Pressing FIRE for two seconds sounds the fi re siren and sends a “fi re” message
✓ Multiple Beeps sound and sensor status indicators fl ash if an alarm has
to a central monitoring station through the digital communicator (if the system is monitored). ★ Pressing EMERGENCY for two seconds sounds the emergency siren and sends
occurred. ☞ Multiple Beeps mean caution. AN INTRUDER MAY STILL BE PRESENT. ★ Chime Mode is for monitoring doors and windows.
✓ Use this mode as an “automatic door chime” when at home. ✓ Opening any protected door or window causes the keypad(s) to “ding-dong”.
an “emergency” message to a central monitoring station through the digital communicator (if the system is monitored). ★ Both work even when system is disarmed. ★ IMPORTANT: For personal emergency use only. Not for use as a UL Listed
★ Home Mode arms the perimeter sensors, but not the interior sensors.
✓ Use this mode when anyone is staying behind. ✓ Interior motion detectors and interior door sensors are not armed. ✓ Home secure mode makes all delayed perimeter sensors instant. ✓ Secure exit mode starts an exit delay while remaining in Home Mode. ✓ Re-entering during the exit delay restarts the exit delay (one time only).
Medical Alert System.
★ Shows the current status of the system.
★ Glows when AC power is on. ★ Blinks when AC power is off and backup battery is installed. ★ Blinks when the backup battery is low, recharging or missing. ★ Off when AC power is off and no backup battery is installed (system disabled).
★ Away Mode arms the entire system.
✓ Use this mode when leaving home. ✓ Door sensors set for delayed will have a time delay that allows the user to
leave and enter the premises without sounding the alarm. ✓ Re-entering during the exit delay restarts the exit delay (one time only). ✓ Entry Delay Beeps warn the user to disarm the system before the siren
★ Blinks when one or more sensors have a low battery. ★ Press for two seconds to view sensor status. Sensor status indicator for any sensor with a low battery will light along with the BATTERIES indicator. ★ Switch to Test Mode after replacing the sensor battery and completely test the
starts.
system (see Test Mode). Switching to Test Mode clears the low battery indication.
★ Test Mode is for testing the system sensors.
✓ All sensor status lights blink when the Test Mode is entered. ✓ Each sensor status light will stop blinking when its sensor is tested. ★ Hold the TEST button down to test all of the keypad's indicator lights.
★ Blinks when one or more sensors have not reported status during the eight hour
status time period. ★ Press for two seconds to view sensor status. Sensor status indicator for any sensor that has not reported in will light along with the TROUBLE indicator. ★ Switch to Test Mode after servicing the sensor and completely test the system
10 SOUNDER ★ Makes unique sounds for burglary, fi re and emergencies. ★ Alarm sirens stop automatically after fi ve minutes. ★ Sounds advisory tones to confi rm keystrokes from the keypad. ★ Sounds mode selection tones. ★ Sounds alarm memory tones. ★ Beeps when Automation Output is activated. ★ The Control Panel has terminals available for an external siren.
(see Test Mode). Switching to Test Mode clears the trouble indication.
★ The indicators next to the mode keys light to show the current system mode. ★ HOME indicator will blink during Secure Exit and Home Instant modes. ★ AWAY indicator will blink during the exit delay in the Away Mode.
11 SPEAKER (OPTIONAL)
★ Location for the high sensitivity microphone included with the Model RSM-2
★ Location for the speaker included with the Model RSM-2 speaker/microphone
speaker/microphone kit. ★ Detects room audio when communicator is reporting to the Central Station
kit. ★ Sounds voice operating prompts and audio from the Central Station (Model
in 2-way audio mode (Model VB-2 digital voice response module and RSM-2 speaker/microphone kit must be installed).
VB-2 digital voice response module and Model RSM-2 required).


8 DIGITAL VOICE RESPONSE MODULE (OPTIONAL)
★ Type 2AG, 3-amp fuse for the backup battery. ★ If the keypad's POWER light is fl ashing and the optional backup battery is
★ The Model VB-2 gives the Control Panel's digital communicator listen-only,
manual 2-way and full duplex 2-way audio capability with the Central Station. ★ The module allows remote command of the system using a standard pushbutton
installed and charged, check this fuse. ✎ WARNING: For continued protection against the risk of fi re, replace only
telephone, on or off site. ★ The module provides optional voice prompts from the keypad(s) (Model RSM-2
with the same type and rating of fuse.
speaker/microphone kit required for each keypad).
★ Four cabinet knockouts are provided for wiring using conduit. ★ The 3/4" knockouts fi t standard 3/4" conduit fi ttings.
★ A cabinet knockout is provided for mounting an external antenna connector. ★ For an external antenna, use Linear's Model LA-P antenna kit. ★ The antenna kit can also be used to connect the Control Panel to co-ax for a
★ Provides access for wiring through a hole in the mounting wall. ★ Route cables for power, telephone, external speaker, etc. through this slot.
remote antenna.
10 ANNUNCIATOR VOLUME CONTROL ★ Varies the volume of the advisory tones that come from the keypad(s) speaker
★ Terminals for hardwired loop inputs. ★ Terminals for Automation Output to connect to an automation controller. ★ Terminals for external relay output for “dry” contacts (Form C, normally open/
when the Model RSM-2 speaker/microphone kit is installed in the keypad. ★ Does not affect keypad's sirens (they are always full volume).
normally closed, 1 amp @ 24 volts maximum). ★ Terminals for fused auxiliary 12 volt output and common ground. ★ Terminals for connection to one or two Model DUAL 824KP keypads. ★ Terminals for connection to the plug-in AC transformer.
★ Used to monitor the Control Panel's radio receiver during troubleshooting. ★ Provides connection for an audio amplifi er to listen to the receiver's output. ★ Helpful to determine sources of radio interference.
12 ANTENNA TERMINALS ★ Antenna and shield (ground) terminals for receiving signals from the system's
★ Type 2AG, 1-amp fuse. ★ Protects the auxiliary power output and siren driver circuit. ★ Fuse will blow when load exceeds 1 amp total. ✎ WARNING: For continued protection against the risk of fi re, replace only
sensors. ★ Pre-wired to the Control Panel's internal wire dipole antenna. ★ Alternately connects to the Model LA-P local whip and remote antenna kit.
with the same type and rating of fuse.
13 OPTIONAL BACKUP BATTERY ★ Space for 12-volt, 4 amp/hour backup battery. (Highly recommended.) ★ Backup battery is automatically charged and monitored by the Control Panel. ★ Backup battery can power the Control Panel for up to 6 hours. ★ UL NOTE: Normal estimated battery life should be 3 to 4 years.
★ Provides telephone connections for the digital communicator. ★ Provides telephone connection for voice prompted telephone remote control
(optional VB-2 digital voice response module required). ★ Provides seized ring and tip connections for local telephone instruments.
14 REMOVABLE CABINET COVER ★ The cabinet cover can be removed for easy system wiring and setup. ★ Two screws secure cabinet cover when closed. ★ An optional cabinet lock can be installed for additional security.
Communicator will disconnect local telephones while on-line.
★ Four slots used when mounting Control Panel to the wall. ★ Used as a template for the Control Panel when it is mounted to the wall.

reach the Control Panel.
✔ Try to centrally locate the Control Panel. ✔ Keep Control Panel away from large metal
USE THE CASE BOTTOM AS A TEMPLATE TO MARK THE FOUR KEYHOLE MOUNTING HOLES

appliances. ✔ Maximum recommended sensor range is 400
feet (system tested at 1000 feet). ✎ NOTE: If you don't use the wireless keypad, a
hardwired keypad should be easily accessible to the usual entrance.
FOR RECESSED WIRING, MARK WIRING SLOT, THEN CUT OUT HOLE WITH DRYWALL SAW
✔ When the Control Panel is set in the Away
Mode, the user has 30 seconds to switch to Off Mode before the burglary siren sounds. ✎ NOTE: Make sure a hardwired keypad is in a place
where the alarm can be heard during the night hours.
✔ Optional remote external sirens (up to 150
feet from the Control Panel) can be used to make alarms louder and remote the sound location. 1. Locate the Control Panel near a 115 VAC outlet that's not controlled by a light switch. 2. Locate the Control Panel near a telephone outlet (if using the digital communicator).

FOR CONDIUT WIRING, PUNCH OUT REQUIRED KNOCKOUTS AND INSTALL 3/4" CONDUIT HUBS IN HOLES
✦ Linear's Model LA-P antenna kit can be used
with the DUAL 824P Control Panel to replace the standard internal antenna. ✦ The antenna can be mounted on the cabinet,
or the kit can be used to connect to co-ax for a remote antenna. 1. Remove the two standard white antenna wires attached to the ANT and SHIELD terminals. 2. Punch out the antenna knockout. 3. Mount the antenna connector in the antenna knockout. 4. Route the antenna co-ax down to the Control Panel's antenna connector. 5. Connect the antenna's co-ax center conductor to the ANT terminal. 6. Connect the antenna's co-ax shield to the SHIELD terminal. 7. Route the two antenna ground wires as shown.

PUNCH OUT ANTENNA KNOCKOUT AND INSTALL LA-P ANTENNA CONNECTOR INTO HOLE
INSTALL THE WHIP ANTENNA AND ROUTE THE TWO GROUND WIRES AS SHOWN
CONNECT CO-AX SHIELD TO SHIELD TERMINAL AND CO-AX CENTER CONDUCTOR TO ANT TERMINAL

HARDWIRED KEYPAD INSTALLATION
TWIST SCREWDRIVER IN SLOTS TO OPEN THE KEYPAD CASE

SET TO "ON"
✦ One or two Model DUAL 824KP keypads can be
used with the DUAL 824P Control Panel (one keypad is included in the DUAL 824 system package). ✦ The keypad is supplied with a short wiring
harness and connector. 1. Use a fl at blade screwdriver to open the keypad case. Identify the keypad internal components. 2. Set the keypad select jumper to KEYPAD 1 if this is the fi rst, or only, keypad installed. Set the jumper to KEYPAD 2 if this is the second keypad installed. 3. For a silent keypad, set the SOUNDER jumper to OFF. 4. Select an indoor location with easy wiring access to the Control Panel and use the keypad's mounting plate as a template to mark the mounting holes for the keypad. 5. Route 4-conductor 22 AWG (or larger) wire from the Control Panel to the keypad(s). Up to 100 feet of wire total can be used with this system. If installing two keypads, each keypad can be “home-run” or “daisy-chained”. ✎ Note: If a Model VB-2 voice response module is
SOUNDER JUMPER CAN BE SET TO "OFF" SET KEYPAD SELECT JUMPER TO "KEYPAD 2" IF THIS IS THE 2ND KEYPAD

MOUNT KEYPAD INDOORS AT A CONVENIENT HEIGHT AND LOCATION FOR THE USERS
USE THE MOUNTING PLATE AS A TEMPLATE TO MARK SCREW LOCATIONS
USE SCREWS AND ANCHORS OR APPROPRIATE FASTENERS TO AFFIX MOUNTING PLATE
going to be used with the system, in addition to the keypad’s four wires, route 2-conductor shielded cable and 2-conductor 22 AWG wire from the Control Panel to the keypad(s) for the keypad’s microphone and speaker. When using two keypads and two microphones, each shielded microphone cable must be home run to the VB-2 terminal block. 6. If using the VB-2 voice response module, refer to the instructions supplied with the Model RSM-2 speaker/microphone kit for details on installing and wiring the keypad’s speaker and/or microphone. 7. Connect the 4-conductor wire to the Control Panel's keypad terminals, noting wire colors. 8. Noting wire colors, connect the keypad's wiring harness to the wire from the Control Panel. 9. Plug the keypad wiring harness into the keypad connector and snap the keypad case closed.
THE MOUNTING PLATE IS ALSO DESIGNED TO BE ATTACHED TO A SINGLE-GANG OUTLET BOX
ROUTE 4-CONDUCTOR 22 AWG WIRE OR LARGER FROM CONTROL PANEL TO KEYPAD
WHITE
KPD DAT
KPD CLK
ORANGE
KPD
BLACK
RED
KPD
TO DUAL 824KP
KEYPAD
ROUTE WIRING CONNECTOR THROUGH MOUNTING PLATE HOLE
IF THE RSM-2 SPEAKER/MICROPHONE KIT IS GOING TO BE USED, RUN AN ADDITIONAL PAIR FOR THE SPEAKER AND A SHIELDED PAIR FOR THE MICROPHONE
ALIGN TOP OF CASE FIRST, THEN SNAP BOTTOM TOGETHER
INSERT CONNECTOR INTO THE KEYED SOCKET ON THE KEYPAD UNTIL IT SNAPS TOGETHER

RUN LOOP WIRING BETWEEN THE CONTROL PANEL AND THE REMOTE HARDWIRED SENSORS
✦ The DUAL 824 supports up to eight normally
open/closed hardwired loops each with 2.2K end-of-line resistor supervision. ✦ Each hardwired loop that is wired and
INFRAREDS
programmed uses one sensor location. ✦ Each hardwired loop can be programmed to any
CONTACTS
sensor number. ✦ Each hardwired loop can be programmed as any
sensor type, including arm/disarm toggle. ✦ Four COM terminals are shared as loop returns
RUN 2-CONDUCTOR WIRE TO DEVICES NOT POWERED FROM THE CONTROL PANEL
for the eight loops. ✦ Each hardwired loop has a 400 millisecond
LOOP
1 COM LOOP
2 LOOP
3 COM LOOP
4 LOOP
N/O COM
8 H/A
H/A
RLY COM
RLY
RLY
+12 VDC
N/C

all hardwired loop wiring. 1. Route wiring from the Control Panel to each hardwired switch contact, sensor, or device. Route the wires through the wiring slot or through a knockout for conduit wiring. ✎ NOTE: Maximum recommended hardwired loop
USE +12 VDC AND ANY COM TERMINAL TO POWER EXTERNAL DEVICES (1 AMP MAX.)
2.2K END-OF-LINE RESISTOR FOR EACH LOOP USED NORMALLY CLOSED SWITCHES (CONTACTS)
length is 500 feet (250' out, and 250' back) for each loop. Maximum loop resistance (excluding the EOL resistor) is 100 ohms. 2. Connect the loop wires to LOOP # and COM terminals. For powered devices connect power wires to +12 VDC and any COM terminal. 3. On the sensor end, connect each normally closed sensor in series with the loop wires. Connect each normally open sensor in parallel with the loop wires. See wiring fi gure. 4. After the last sensor on the loop, connect a 2.2K end-of-line resistor across the loop. ✎ NOTE: Before the hardwired loops will function,

CONNECT EACH HARDWIRED INPUT TO A LOOP AND COM TERMINAL
FOR POWERED DEVICES, WIRE POWER LEADS TO +12 VDC AND ANY COMMON TERMINAL (OBSERVE POLARITY)
they will need to be programmed. This will be covered in the Basic Control Panel Programming section of this manual.
MAIN TERMINAL BLOCK
✦ Any of the hardwired loops can be used with a
1 COM LOOP
2 LOOP
3 COM LOOP
4 LOOP
N/O COM
8 H/A
H/A
RLY COM
RLY
RLY
N/C
momentary keyswitch to arm and disarm the system. 1. Connect the loop as shown to the keyswitch and end-of-line resistor. 2. Connect an LED indicator from the switch plate to the H/A- and H/A+ terminals. 3. When programming the system, set the loop sensor function to “Type 9, Arm/Disarm Toggle” and set the Automation output to “Active while Armed”.

+ · +

✦ An external siren alerts occupants and neighbors
with a loud siren during alarm. ✦ Use a 12 volt, 1 amp maximum rated weather-
ALARM
resistant horn speaker with a built-in siren driver. Do not use a plain speaker without a siren driver. ✎ NOTE: Connection of an electromechanical bell or
motor bell is not recommended because of the radio interference generated when the bell is running.
LOOP
8 H/A
H/A
RLY COM
RLY
RLY
+12 VDC
N/C
installations. 1. Mount the external siren. 2. Route the wires from the external siren to the Control Panel. 3. Route the siren wires up through the wiring access slot or through a knockout when using conduit. 4. Connect a jumper wire from the +12 VDC terminal to the RLY COM terminal. 5. Connect the positive siren wire to the RELAY N/O terminal. 6. Connect the negative siren wire to one of the COM terminals. ✎ NOTE: The relay contacts are isolated. Use the

INSTALL WIRE JUMPER TO PROVIDE POWER TO RELAY CONTACTS
12 VDC 1 AMP MAXIMUM

RLY N/O & RLY COM terminals alone to switch an externally powered load.
INSTALL A JUMPER WIRE BETWEEN THE +12 VDC AND RLY COM TERMINALS
✦ Connect the Control Panel to the telephone
line if the system is monitored, requires 2-way audio, telephone remote command, or for remote programming with RA-2400 software. ✦ Telephone RING & TIP terminals are for
connection to the incoming telephone line. ✦ Seized telephone ring & tip (R1 & T1) are for
LINE TIP (T)
SEIZED RING (R1)

connection to local telephone sets. When the communicator activates, all the local telephone sets will be disconnected to prevent an off-hook telephone on the premises from blocking the communicator call. 1. Install a USOC RJ31-X or RJ38-X jack to the telephone system near the Control Panel. 2. Route an appropriate modular telephone line cord from the jack to the Control Panel. 3. Route the line cord through the Control Panel's wiring access slot or through a knockout for conduit wiring. 4. Connect the incoming telephone line wires to the Control Panel's telephone terminal block TIP and RING terminals. 5. Connect the local telephone set wires to the Control Panel's telephone terminal block T1 and R1 terminals. ✦ When directly connecting (without a telephone line)

CONNECT INCOMMING AND OUTGOING TELEPHONE LINES TO THE TELEPHONE TERMINAL BLOCK
to the DUAL 824 with the RA-2400 remote access software (Version 1.3 or later), disconnect the incoming telephone line and connect the modem to the panel's TIP and RING terminals (with the modem's red & green phone line wires). Press the EMERGENCY key while in Test Mode to cause the panel to connect to the modem.
+


✦ The Control Panel provides a Automation Output
8 H/A
H/A
RLY COM
to control lights, devices and appliances. ✦ Automation Output can connect to most popular
ANY SENSOR CAN BE PROGRAMMED TO TOGGLE THE AUTOMATION OUTPUT
home automation devices and other simple electronic devices (see fi gure). ✦ Press to turn the Automation Output on, press again to turn it off.
THE POSITIVE H/A TERMINAL PROVIDES +12 VOLTS DC AND IS CURRENT LIMITED AT 40 MILLIAMPS MAXIMUM
PRESS THE KEY ON ANY SYSTEM KEYPAD TO TOGGLE THE AUTOMATION OUTPUT
THE NEGATIVE H/A TERMINAL WILL SWITCH TO GROUND WHEN AUTOMATION OUTPUT IS ACTIVATED
✦ There are many programmable options for the
Automation Output. ✦ The Automation Output can be programmed for
a variety of useful functions, such as: fl ashing during alarm, fl ashing after an alarm, on while armed, or, on during exit/entry delays. ✦ See the “Advanced Programming” section of this
H/A + H/A - H/A + H/A - H/A + H/A -
manual for details on changing the function of the Automation Output.
X-10 BURGLAR ALARM INTERFACE (CAN CONTROL HOUSE LIGHTS THROUGH X-10 SYSTEM)
YOUR LOAD
X-10 LINEAR RB-90 RELAY MODULE
✦ The DUAL 824P circuit board has a plug-in
location for a Model VB-2 voice response module. ✦ The VB-2 module allows remote command
of the system locally and remotely through a pushbutton telephone. ✎ NOTE: The following two features require a Model

RSM-2 speaker/microphone kit installed in the keypad. ✦ The VB-2 module can sound voice prompts
through a speaker installed in the keypad. ✦ The VB-2 module supports listen-only audio,
two-way manual audio, and full duplex two-way audio communication with the Central Station through a microphone installed in the keypad. ✎ NOTE: Refer to the VB-2 instructions for details on
operating the voice response module.
Voice Response Module Installation
1. Identify the audio module components, noting the terminal block positions. 2. Connect shielded microphone wire to the VB-2 MICROPHONE COMMON (for shield) and MICROPHONE #1 (for center conductor) terminals. Connect the other end of the wire’s shield to the BLACK, and center conductor to the RED microphone wires in the keypad. 3. If using two keypads for audio monitoring, repeat Step 2 for the second keypad, except connect the center conductor to the VB-2 MICROPHONE #2 terminal. 4. WITHOUT POWER APPLIED TO THE CONTROL PANEL, plug the voice response module into the sockets on the Control Panel's circuit board. Be sure the arrows on the module board are pointing up. 5. Connect 2-conductor wire from the Control Panel’s KPD SPK+ and KPD SPK- terminals to the two speaker wires in the keypad.
CAREFULLY PLUG VOICE MODULE INTO THE TWO CIRCUIT BOARD SOCKETS BE SURE ALL PINS ARE ALIGNED BOARD ARROWS POINT UP

+ · Programmable Options

MAIN TERMINAL BLOCK
✦ The Control Panel is powered by a low voltage
plug-in transformer. ✦ Use up to 25 feet of 20 AWG or larger
KPD CLK
KPD DAT
KPD SPK +

2-conductor wire to connect the transformer to the Control Panel. 1. Route the power wires from the plug-in transformer to the Control Panel. 2. Connect the wires to the transformer terminals (do not plug the transformer in until the wiring is complete). 3. Route the power wires through the Control Panel's wiring access slot or through a knockout for conduit wiring. 4. Connect the power wires from the transformer to the Control Panel's main terminal block AC & AC terminals. 5. Plug transformer into an unswitched AC outlet. 6. Secure transformer with screw to prevent unplugging.
16 VAC, 28 VA BE SURE TO SELECT AN UN-SWITCHED AC OUTLET FOR THE TRANSFORMER

CONNECT TRANSFORMER WIRES TO THE AC TERMINALS ON THE MAIN TERMINAL BLOCK

PLUG TRANSFORMER INTO 115 VAC OUTLET THAT IS NOT CONTROLED BY A LIGHT SWITCH
BE SURE RED WIRE ATTACHES TO POSITIVE (+) TERMINAL, AND BLACK WIRE ATTACHES TO NEGATIVE (-) TERMINAL
✦ A 12-volt backup battery may be installed and is
AFTER ALL WIRING IS COMPLETE, CONNECT THE BACKUP BATTERY
highly recommended. ✦ The backup battery will power the system for up

to 6 hours during AC power loss. ✦ The backup battery is automatically charged by
the Control Panel when AC power is present. ✦ A low backup battery will cause the keypad's
POWER indicator to fl ash as it is being charged. 1. Position the battery as shown. 2. Connect the black battery lead to the negative battery terminal. 3. Connect the red battery lead to the positive battery terminal. ✎ WARNING: DO NOT REVERSE THE BATTERY
LEADS! THE BATTERY FUSE WILL BLOW.

✦ In a new installation, when power is fi rst
applied the system's master user code is “1234”.
ENTERING
SETTING A NEW MASTER
MODE
USER CODE
the system's hardwired keypad, not on a wireless keypad. 1. Press (clears keypad if any other keys have been pressed). 2. Place the system in Test Mode (enter 1234 and press TEST. ✴ A “gong” and four “beeps” will sound. 3. Enter the Setup Mode from Test Mode, enter 1234 then press TEST again. ✴ A “gong” and fi ve “beeps” will sound. The system is now
START IN SETUP MODE
CLEARS KEYPAD
PROGRAMMING STEP #99
DEFAULT MASTER USER CODE
in Test Mode. 4. Enter 99 then press HOME. 5. Enter any combination of 1-5 digits for the master user code, then press AWAY. ✎ NOTE: For maximum security, a three to fi ve digit
1 GONG & 4 BEEPS (TEST MODE)
code is recommended. 6. Press and hold the OFF key for 3 seconds to exit program mode. 7. Test the new master user code by entering it then pressing TEST. 8. Log the master user code in the box below.
DEFAULT MASTER USER CODE
HOLD FOR 3 SECONDS TO EXIT SETUP
DONE
MASTER USER CODE:
1 GONG & 5 BEEPS (SETUP MODE)
Setup Mode. The restricted user codes cannot. To create restricted user codes, see the “Advanced Programming” section of this manual.

START IN TEST
✦ Each hardwired loop used must be programmed
into the Control Panel's memory. ✦ Each hardwired loop programmed uses one of
the twenty four available sensor locations. 1. Start with the system in Test Mode (enter the master user code and press TEST). 2. Enter the Setup Mode from Test Mode, enter the master user code then press TEST again. ✴ A “Gong” and fi ve “Beeps” will sound. The system is now
1 GONG & 5 BEEPS (SETUP MODE)
in Setup Mode. ✴ The sensor status indicators will light for any sensors
already programmed into the Control Panel. 3. Enter programming Step #301-308 (301=loop 1, 302=loop 2, etc.) for the hardwired loop desired. 4. Press HOME to select step. 5. Enter an unused sensor number from 01-24 for the loop (you must enter two digits, example: 5 = 05). 6. Press AWAY to store. ✴ A single “Bing” tone will sound and the sensor status
SENSOR NUMBER (01-24) FOR LOOP
indicator for that sensor will stay lit. A double “Buzz” will sound if that sensor location is already in use. 7. Repeat Steps 3-6 to enable all of the hardwired loops used. ✎ NOTE: The default sensor function for the
hardwired loops is Perimeter (Type 5). Any sensor function can be selected for each hardwired loop, refer to the “Customizing the System” section of this manual.
PROGRAM THE WIRELESS SENSORS
✦ Each wireless sensor used must be programmed
into the system’s memory. See the next two pages for details on activating different models of transmitters. ✦ Each wireless sensor programmed uses one of
the twenty four available sensor locations. 1. Start with the system in Test Mode (enter any user code and press TEST). 2. Enter the Setup Mode from Test Mode, enter the master user code then press TEST again. ✴ A “Gong” and fi ve “Beeps” will sound. The system is now
1 GONG & 5 BEEPS (SETUP MODE)
in Setup Mode. ✴ The sensor status indicators will light for any sensors
programmed into the Control Panel. 3. Enter an unused sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✴ The sensor indicator light will fl ash for the sensor number
SENSOR INDICATOR FLASHES
selected. 4. Activate the sensor by sending a test or alarm signal (be sure the sensor's battery is connected or that its battery protection strip is removed). ✴ A single “Bing” tone will sound and the sensor status
indicator for that sensor will stay lit. A “Buzz” will sound if that sensor location is already in use. 5. Repeat Steps 3 & 4 for each additional sensor, or exit Setup Mode by pressing the OFF button for three seconds.
REPEAT OR EXIT

✦ Follow the instructions on the previous page to
select a sensor number to program the sensor into. ✎ NOTE: A sensor can be programmed into more

than one location. Be sure to choose an UNUSED sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function. ✦ To add DXS-10 wireless keypads, press and hold
the keypad's key until programmed into the Control Panel. ✦ For DXS-31 and DXS-32 door/window sensors,

move the magnet away from the side of the sensor. ✎ IMPORTANT NOTE: The DXS-31 & DXS-32 door/
window sensors are pre-set at the factory for delayed burglary response. If the sensor is going to be used on a non-entry portal (window, sliding glass door, etc.) a jumper can be changed in the sensor to select instant response. The jumper should be changed before programming the sensor so the Control Panel will assign the sensor to the proper sensor function. See the “Basic Sensor Installation” section of this manual or the sensor’s instructions for details on changing the jumper. ✦ For DXS-81, DXS-91, DXS-54, DXS-73,

& accessory sensors, simply send a test transmission (refer to the sensor's instructions for details on sending a test transmission).


✦ For DXT-61, DXT-21, DXS-21, DXT-41, &
DXS-62A single-button remotes, simply press the unit's button. ✎ NOTE: After the Control Panel recognizes the
transmitter, single-button remotes must be re-programmed as “panic buttons” or home automation controllers. Refer to Page 28 in the “Customizing the System” section of this manual. ✦ For DXT-23, DXS-23, & DXT-42 multi-button
remotes: Learn the transmitter by pressing the left button. The remote will arm the Control Panel with the left button and disarm with the right button. Labels are provided with the DXT-42 for identifying the buttons. ✎ NOTE: After the Control Panel “learns” the
transmitter, multi-button remotes can easily be re-programmed to have the left button arm/disarm the Control Panel and the right button activate/ deactivate the Home Automation output. Refer to the “Advanced Programming” section of this manual.

For All Models:
✴ A single “Bing” tone will sound and the sensor status
indicator will stay lit when the sensor is programmed into the Control Panel. ✴ A “Buzz” tone will sound if there is already another
sensor programmed to that sensor number. ✦ Exit Setup Mode by pressing the key then press OFF for three seconds. Reminder: The system will automatically exit the Setup Mode and return to Off Mode after three minutes of keypad inactivity. ✎ NOTE: To remove sensors from the Control Panel's
LEFT = ARM/DISARM RIGHT = DISARM BOTH = EMERGENCY
memory, see Page 26 in the “Customizing the System” section of this manual.


✦ Each accessory sensor is packaged with its
FROM TOP OF CASE TWIST SCREWDRIVER BETWEEN CASE HALVES UNTIL IT POPS OPEN
own set of installation instructions specifi c to the model of sensor. ✦ Refer to the sensor's instructions for details
on installing, operating, and testing of the sensor. ✦ Following are basic instructions for installing
two popular DUAL 824 accessories: The Model DXS-10 Wireless Remote Keypad and the Model DXS-31 & DXS-32 Door/Window Transmitters.
✦ The DXS-10 is used to remotely operate the
system. ✦ The keypad can be simply set on a table or
mounted to a fl at surface.
✦ Four anti-mar pads are provided as a scratch
deterrent for the keypad. ✎ NOTE: Do not use the adhesive pads if the keypad
is going to be wall mounted. 1. Peel off the adhesive tape backing on the pads and stick them to the back of the keypad. ✦ The wireless keypad can be used as a portable
USE THE FOUR SCRATCH DETERRENT PADS PROVIDED FOR TABLE-TOP USE
keypad. Because of the hourly supervisory transmissions, if the unit is taken out of range from the Control Panel for more than eight hours, the hardwired keypad will indicate “radio trouble” for the wireless keypad. The keypad's sensor number can be programmed for “non-supervised” if required. See the “Advanced Programming” section of this manual.

✦ The wireless keypad can be wall mounted. 1. Open the keypad by inserting a small screwdriver in one of the top slots in the keypad case. Gently twist the screwdriver until the case pops open. 2. Attach the rear case to the wall using the two screws provided. ✎ NOTE: For best signal transmission, the keypad
should be mounted at least three feet above ground level. 3. Hook the top edge of the keypad case together and snap the keypad onto the rear case. ✎ WARNING: The wireless keypad is designed for
ATTACH REAR CASE TO WALL WITH THE TWO SCREWS PROVIDED
indoor use only.
MOUNT AT A CONVENIENT LOCATION NEAR PRIMARY ENTRY/EXIT DOOR

DXS-31 & DXS-32 DOOR/WINDOW SENSORS
✦ The DXS-31 and DXS-32 sensors can be used

to monitor doors, windows, cabinets, crawl space doors, gates, freezer doors, and many other moving objects that could be used for intrusion or need to be monitored. ✦ A built-in magnetic switch triggers the sensor
when its magnet (mounted on the moving part or the door or window) moves away from the sensor. ✦ The DXS-31 sensor can be wired to external
normally closed switches for remote triggering. ✦ The DXS-31 sensor can connect directly to a
glass break detector.
INSTANT/DELAY OPTION JUMPER
ANTENNA
✦ A jumper inside the door/window sensor selects
INPUT SELECT JUMPER
TWO TYPE 2032 BATTERIES
instant or delayed response. 1A. If the sensor is going to be used on the primary entry/exit door make sure that the jumper is in the DELAY position. 1B. If the sensor is going to be used on a window or a door that is not going to be used to enter and exit the premises, set the jumper to the INSTANT position.
TRANSMIT INDICATOR
BATTERY CLAMP
TEST SWITCH
EXTERNAL INPUT TERMINALS
CHOOSE MOUNTING METHOD
INSTANT/DELAY OPTION JUMPER
2A. Apply double-stick tape (supplied) to back of sensors and magnets. 2B. Screws are also provided to mount sensors and magnets. Screws are preferred over the double- stick tape in permanent installations. ✎ UL NOTE: Double-stick tape is not allowed in UL
SELECTS DELAY
installations.
✦ Allow a maximum of 1/2" between magnet and
ATTACH MOUNTING PLATES USING THE SCREWS OR DOUBLE-STICK TAPE PROVIDED
sensor when door/window is closed. ✦ The magnet height is adjustable and an optional
magnet spacer is provided for uneven surfaces. 3A. On doors, mount sensor to door frame and magnet to door. 3B. On windows, mount sensor to window frame and magnet to window. ✎ NOTE: Magnet must line up with mark on sensor
case both horizontally & vertically. 4. Snap sensor onto mounting plate.
✴ In Chime Mode, the hardwired keypad(s) should “ding-
dong” when the sensor sends a signal. 5. Open door or window. ✴ Verify that light on the sensor (if there is one) glows

momentarily when door/window is opened. ✴ Status indicator on the hardwired keypad(s) should
remain lit for each door/window sensor that is left open.

✦ The system can be customized for the specifi c

installation. ✦ A label sheet with sensor location names is
provided with DUAL 824KP keypads. ✦ Labeling the sensors allows quick and easy
identifi cation of where a door or window is open, where any alarms have occurred, where a sensor with a low battery is, or where a sensor with trouble is.
1. Open the keypad's plastic beauty cover to reveal the sensor identifi cation label area. 2. Open one protected door/window to light its sensor status light on the keypad(s). 3. Choose a label that describes the sensor location, or write the location on a blank label, and stick it in the area next to the sensor number. 4. Close the protected opening that you just labeled. 5. Repeat for each protected opening. 6. Stick the WIRELESS KEYPAD label in the sensor number location for the wireless keypad (if used). 7. Close the beauty cover when fi nished.

OPEN DOOR OR WINDOW TO LIGHT SENSOR STATUS INDICATOR ON KEYPAD(S)
USE SENSOR LABELS SUPPLIED TO IDENTIFY EACH SENSOR LOCATION

APPLY THE PRE-PRINTED SENSOR LOCATION LABELS TO SUIT THE INSTALLATION
BLANK LABELS THAT CAN BE FILLED IN WITH AN INK PEN ARE ALSO PROVIDED FOR CUSTOM SENSOR IDENTIFICATION

✦ Use this mode to disarm the burglary portion of
the system. ✦ The 24-hour functions are still active in Off Mode
and can be triggered with wireless or hardwired sensors, or by pressing the FIRE or EMERGENCY on the keypad(s). 1. Switch to Off Mode by entering the user code, and pressing OFF. ✎ NOTE: The keypad's key resets the keypad's keyboard and can be used before entering any code to assure that any digits recently pressed will not be added to the correct code. Pressing fi rst is optional because the keypad will reset itself after 10 seconds of keyboard inactivity. ✴ When the system is disarmed to Off Mode, the keypad(s)
YOUR USER CODE
1 GONG
will sound one “Gong”. ✦ Switching to Off Mode stops any alarms in
progress. ✴ If an alarm has occurred, multiple Beeps will sound after
disarming and the sensor indicator for the sensor(s) that caused the alarm will fl ash. ✎ NOTE: In Off Mode, protected doors and windows
cannot trigger the burglary alarm.
✦ Chime Mode is for monitoring entries and exits
without causing alarms. ✦ Use Chime Mode as an “automatic door chime”
when at home. ✴ Opening any protected door or window causes the
keypad(s) to sound a “ding-dong”. 1A. Select the Chime Mode by entering a user code, then press CHIME. 1B. The user can enter Chime Mode from Off Mode by pressing CHIME for two seconds. ✴ When the system is switched to the Chime Mode, the
keypad(s) will sound a “Gong” and one “Beep”. ✦ Switching to Chime Mode disarms the system
and stops any alarms in progress. ✴ If an alarm has occurred, multiple Beeps will sound after
disarming and the sensor indicator for the sensor(s) that caused the alarm will fl ash. ✎ NOTE: In Chime Mode, protected doors and
windows cannot trigger the burglary alarm.
HOLD DOWN
1 GONG & 1 BEEP DONE

MANUAL BYPASSING OF SENSORS
✦ Use this mode when sleeping or when anyone is
✦ Manual bypassing of sensors in the Home Mode
staying inside. ✦ Home Mode causes an instant alarm when any
allows arming of the system at night with open windows, while still having perimeter protection with other closed doors and windows. ✦ If the READY indicator is lit, all sensors are closed. 1. If the READY indicator is not lit, the system will resist arming because of open door or window sensors. ✴ Four high-low Beeps to warn the user that something is
perimeter sensor is triggered. ✦ Home Mode causes a delayed alarm when any
exit/entry sensor is triggered (except in Home Instant Mode when they are instant). ✦ Each burglary sensor can trigger the siren once
per arming period. ✦ Alarm siren stops automatically after fi ve minutes
open and the system will remain in the previous mode. ✴ Lit sensor status indicators show which sensors are
and the system will remain armed. ✦ Home Mode ignores all interior sensors (motion
open. 2. To manually bypass the open sensors, arm the system again within fi ve seconds. ✴ A “Gong” and two “Beeps” will sound, the HOME
detectors, etc.). 1A. Arm to Home Mode by entering a user code, and pressing HOME. 1B. The user can “Quick Arm” to Home Mode from Off or Chime Mode by pressing HOME for two seconds. (Quick arming can be disabled; see the “Advanced Programming” section of this manual.) ✴ When the system is armed to the Home Mode, the
indicator will light, and the open sensors will be bypassed. ✎ WARNING: Bypassed sensors cannot cause an
alarm. Closing the sensor removes the bypass.
keypad(s) will sound a “Gong” and two “Beeps”. 2. Enter a user code and press OFF or CHIME to disarm from Home Mode and/or stop the alarm siren. ✴ If an alarm has occurred, multiple Beeps will sound after
SECURE EXIT
disarming and the sensor indicator for the sensor(s) that caused the alarm will fl ash (switch to Off Mode again or re-arm the system to stop the fl ashing alarm memory).
START IN HOME MODE
(OPTIONAL)
(OPTIONAL)
SECURE EXIT
YOUR USER CODE
Beeps will sound during the Exit Delay. 2A. The user can leave through a door with a delayed perimeter sensor during the 60 second Exit Delay without causing the Control Panel to begin an Entry Delay. 2B. Re-entering during the silent Exit Delay will extend the Exit Delay another 60 seconds (one time only). ✎ NOTE: The Exit Delay time can be changed; see the
1 GONG & 2 BEEPS
DONE
DONE
OR QUICK ARM TO HOME MODE
HOME INSTANT
MODE
“Advanced Programming” section of this manual.
START IN OFF OR CHIME MODE
START IN HOME MODE
HOLD DOWN
1 GONG & 2 BEEPS DONE
1 GONG & 2 BEEPS DONE
light and ARMED indicator will blink continuously. 2. Because all exit/entry sensors will now cause an instant alarm when in Home Mode, the system must be disarmed before opening any exit/entry delay door. ✎ NOTE: If quick arming is disabled the Home Instant
Mode is unavailable.

MANUAL BYPASSING OF SENSORS
✦ Use this mode when no one will be staying home. ✦ Away Mode causes an instant alarm when any
✦ Manual bypassing of sensors in the Away Mode
allows arming of the system with open doors and windows, while still having perimeter protection with other closed doors and windows. ✦ If the READY indicator is lit, all sensors are closed. 1. If the READY indicator is not lit, the system will resist arming because of open door or window sensors. ✴ Four high-low Beeps to warn the user that something is
perimeter sensor is triggered. ✦ Away Mode causes a delayed alarm when any
exit/entry sensor is triggered. ✦ Away Mode causes an instant alarm when any
interior sensors (motion detectors, etc.) are triggered. The interior sensors will be delayed if a perimeter delayed sensor is triggered fi rst. ✦ Each burglary sensor can trigger the siren once
open and the system will remain in the previous mode. ✴ Lit sensor status indicators show which sensors are
per arming period. ✦ Alarm siren stops automatically after fi ve minutes
open. 2. To manually bypass the open sensors, arm the system again within fi ve seconds. ✴ A “Gong” and three “Beeps” will sound, the AWAY
and the system will remain armed. 1A. Arm to Away Mode by entering a user code, and pressing AWAY. 1B. The user can “Quick Arm” to Away Mode from Home, Chime or Off Mode by pressing AWAY for two seconds. (Quick arming can be disabled; see the “Advanced Programming” section of this manual.)
indicator will light, and the open sensors will be bypassed. ✎ WARNING: Bypassed sensors cannot cause an
alarm. Closing the sensor removes the bypass.
EXIT DELAY (For Leaving the Premises)
✴ When the system is armed to the Away Mode, the
keypad(s) will sound a “Gong” and three “Beeps”. ✴ During the 60 second Exit Delay, the keypad(s) will
sound “Beeps” (double Beeps last 10 seconds) and the AWAY and ARMED indicators will blink. 2A. The Exit Delay gives the user 60 seconds to leave the premises through an exit/entry door without triggering an alarm. 2B. Re-entering during the Exit Delay will extend the Exit Delay another 60 seconds (one time only). ✴ When the Exit Delay is over, the keypad(s) will sound one
(OPTIONAL)
“Gong” to warn the user that the system is fully armed and the ARMED indicator will light steady. ✎ NOTE: The Exit Delay time can be changed; see the
“Advanced Programming” section of this manual.
ENTRY DELAY (For Entering the Premises) 3A. The Entry Delay gives the user 30 seconds to enter the premises through an exit/entry door without triggering an alarm. 3B. If a exit/entry sensor is triggered, starting the Entry Delay, the interior sensors will also become delayed (this allows motion in the premises during the Entry Delay). ✴ During the 30 second Entry Delay, the keypad(s) will
DONE
sound “Beeps”. 4. When the Entry Delay is over, the system will go into full alarm and sound the siren if it is not disarmed to the Off or Chime Mode. ✴ If an alarm has occurred while the user was gone,
multiple Beeps will sound after disarming and the sensor light for the sensor(s) that caused the alarm will fl ash (switch to Off Mode again or re-arm the Control Panel to stop the fl ashing alarm memory). ✎ NOTE: The Entry Delay time can be changed; see the
1 GONG & 3 BEEPS DONE
“Advanced Programming” section of this manual.

Mode, it will automatically switch back to Off Mode after three minutes. ✦ When directly connecting (without a telephone
✦ Even though this is a self-monitoring supervised
system, the National Burglar and Fire Alarm Association recommends that all security systems be tested manually on a regular basis. 1. The system must be in Off Mode before switching to Test Mode. 2. Switch the system into Test Mode by entering a user code and pressing TEST. ✴ When the system is switched to the Test Mode, the
line) to the DUAL 824 with the RA-2400 remote access software (Version 1.3 or later), press the EMERGENCY key while in Test Mode to cause the control panel to connect to the modem.
keypad(s) will sound a “Gong” and four “Beeps”. 3. Holding down the TEST button in Test Mode will light all of the keypad’s indicators. ✴ The sensor status indicators will fl ash for each sensor

programmed into the Control Panel. 4. Go to each sensor and press its test button or open and close the protected opening. 5. To test the wireless keypad, press the wireless keypad’s key. ✴ The keypad(s) will make a “Bing” sound as each sensor
is tested, followed by 1-3 beeps indicating signal strength with 3 beeps being the strongest signal. ✴ As each sensor is tested, the sensor status indicator for
the sensor will stop fl ashing and return to showing the current status of the sensor. 6. Continue testing until there are no fl ashing sensor status indicators.

SENSOR FUNCTION OFF MODE CHIME MODE HOME MODE AWAY MODE
2-BUTTON ARM/DISARM (LEFT) 2-BUTTON AUTOMATION (RIGHT) EMERGENCY (BOTH BUTTONS)
LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE † IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡ LEFT BUTTON SWITCHES SYSTEM TO OFF MODE ‡
2-BUTTON ARM (LEFT) 2-BUTTON DISARM (RIGHT) EMERGENCY (BOTH BUTTONS)
LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE † IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡ RIGHT BUTTON SWITCHES SYSTEM TO OFF MODE ‡
† CAN BE HOME MODE USING PROGRAMMING STEP 50 ‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51

✦ The DUAL 824P Control Panel is a self-
monitoring supervised wireless system. If the Control Panel detects a problem with any of the supervised system sensors or with its power, it will display the appropriate trouble indication and, if monitored, report the trouble to the Central Station through the communicator (depending on communicator programming).
TROUBLE INDICATOR
✦ The Control Panel constantly charges and

monitors the optional backup battery (if installed). ✴ The POWER indicator normally glows when AC power is
on. ✦ If the Control Panel’s power condition is
POWER INDICATOR NORMALLY ON WITH AC POWER AND CHARGED BACKUP BATTERY
abnormal, the keypad's TROUBLE indicator will light. The POWER light will indicate the type of trouble. ✴ With a charged backup battery installed, if the Control
BLINKS WHEN AC POWER IS ABSENT AND CONTROL PANEL IS RUNNING ON BACKUP BATTERY
Panel looses AC power, the POWER indicator will blink as the Control Panel runs on the backup battery. ✴ If the backup battery is low, recharging, or not installed,
the POWER indicator blinks when AC power is present. ✴ If the AC power is off and no backup battery is installed,
or the battery fuse is blown, the POWER indicator will be off (in this case, the system has no power, all indicators are dark, and the system is disabled). ✦ Normal battery life for the type of backup battery

TROUBLE INDICATOR LIGHTS IF THERE IS SENSOR BATTERY TROUBLE
used in the Control Panel is 3-4 years. If the battery does not take a charge in 72 hours, it should be replaced.
✴ If the TROUBLE indicator lights, and the BATTERIES
indicator is blinking, one or more wireless sensors have a low battery. 1. Press for one second to view sensor status. The sensor status indicator for any sensor with a low battery will light along with the BATTERIES indicator. 2. Replace the wireless sensor's battery as described in its instructions. 3. Switch to Test Mode after replacing the wireless sensor battery and completely test the system (see Test Mode). Switching to Test Mode clears the trouble indication.
BLINKS WHEN ONE OR MORE WIRELESS SENSORS HAVE A LOW BATTERY
LIGHTS WITH SENSOR # INDICATION DURING LOW BATTERY STATUS CHECK (PRESS FOR 1 SECOND)

✴ If the TROUBLE indicator lights, and the RADIO indicator
is blinking, status reports from one or more wireless sensors have not received in eight hours. 1. Press for one second to view sensor status. The sensor status indicator for any sensor with trouble will light along with the RADIO indicator. 2. Switch to Test Mode after servicing the sensor and completely test the system (see Test Mode). Switching to Test Mode clears the trouble indication.
BLINKS WHEN STATUS SIGNALS FROM ONE OR MORE WIRELESS SENSORS HAVE NOT BEEN RECEIVED IN EIGHT HOURS
LIGHTS WITH SENSOR # INDICATION DURING RADIO STATUS CHECK (PRESS FOR 1 SECOND)

✦ Adding additional sensors will increase the
protection provided by the system. ✦ All ground-level perimeter openings and
accessible upper-story openings need protection. ✦ Motion detectors can protect interior areas and
areas where valuables are kept.
NEW SENSOR NUMBER
programmed into the Control Panel. 3. Enter an unused sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✎ NOTE: A sensor can be programmed into more
than one location. Be sure to choose an UNUSED sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function. ✴ The sensor status indicator light will fl ash for the sensor
1 BING AND SENSOR INDICATOR LIGHTS
number selected. 4. Activate the sensor. (To add a wireless keypad, press the keypad's key.) ✴ A “Bing” tone will sound when the sensor is programmed
into the Control Panel and the sensor status indicator will stay lit. ✴ A “Buzz” tone will sound if there is already another
sensor programmed to that sensor number. 5. Enter another sensor number, or exit Setup Mode by pressing the key then press OFF for three seconds.
REMOVING SENSORS FROM THE SYSTEM
✦ If a previously programmed sensor isn't going
to be used with the system anymore, or it's a duplicate that has been entered into more than one sensor location, it should be removed from the Control Panel's memory. 1. Start with the system in Test Mode. 2. Enter the master user code then press TEST. ✴ A “Gong” and fi ve “Beeps” will sound. ✴ The sensor status indicators will light for each sensor
1 GONG & 5 BEEPS (SETUP MODE)
programmed into the Control Panel. 3. Enter the sensor number (from 01-24) that you want to remove (you must enter two digits, example: 5 = 05). ✴ The sensor status indicator light will fl ash for the sensor
SENSOR INDICATOR FLASHES
number selected. 4. Press TEST. ✴ A “Bing” tone will sound when the sensor has been
removed and the sensor status indicator will turn off. 5. Enter another sensor number, or exit Setup Mode by pressing the key then press OFF for three seconds.
REPEAT OR EXIT

START IN TEST
✦ Sensors can be programmed to cause the
keypad(s) to chime any time they're activated. ✦ Chime-only sensors will not be able to trigger the
alarm in any system mode. ✦ The sensor must have already been programmed
into the Control Panel (see “Adding Sensors to the System” for details). 1. Start with the system in Test Mode. 2. Enter the master user code then press TEST. ✴ A “Gong” and fi ve “Beeps” will sound. ✴ The sensor status indicators will light for each sensor
NUMBER OF SENSOR TO CHANGE
programmed into the Control Panel. 3. Enter the sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✴ The sensor status indicator light will fl ash for the sensor
number selected. 4. Press HOME, 8, then AWAY. ✴ A “Bing” tone will sound and the sensor status indicator
will light steady. 5. Enter another sensor number, or exit Setup Mode by pressing the key then press OFF for three seconds.
STORES CHANGE
1 BING AND SENSOR INDICATOR LIT
MAKING A SENSOR INTERIOR
✦ Wireless motion detectors are automatically
programmed as interior sensors. Any other sensor can also be programmed as an interior sensor. ✦ Interior sensors can only trigger an alarm when
MASTER USER CODE
the system is in the Away Mode. ✦ “Home Interior” sensors can trigger an alarm
when the Control Panel is in the Home or Away mode. ✦ The sensor must have already been programmed
into the Control Panel (see “Adding Sensors to the System” for details). 1. Start with the system in Test Mode. 2. Enter the master user code then press TEST. ✴ A “Gong” and fi ve “Beeps” will sound. ✴ The sensor status indicators will light for each sensor
SENSOR INDICATOR FLASHES
programmed into the Control Panel. 3. Enter the sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✴ The sensor status indicator light will fl ash for the sensor
ENTERS SENSOR NUMBER 7 TO SELECT INTERIOR SENSOR FUNCTION
number selected. 4. Press HOME, 7, then AWAY. ✴ A “Bing” tone will sound and the sensor status indicator
will light steady. 5. Enter another sensor number, or exit Setup Mode by pressing the key then press OFF for three seconds.


✦ Sensors can be reprogrammed to perform
different sensor functions. ✦ The sensor must have already been programmed
into the Control Panel (see “Adding sensors to the System” for details). 1. Start with the system in Test Mode. 2. Enter the master user code then press TEST. ✴ A “Gong” and fi ve “Beeps” will sound. ✴ The sensor status indicators will light for each sensor
programmed into the Control Panel. 3. Enter the sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✴ The sensor status indicator light will fl ash for the sensor
number selected. 4. Choose a sensor function number from the Sensor Function Table. 5. Press HOME, the new sensor function number, then AWAY. ✴ A “Bing” tone will sound and the sensor status indicator
will light steady. 6. Enter another sensor number or exit Setup Mode by pressing the key then press OFF for three seconds.

FUNC- TION # SENSOR FUNCTION OFF MODE CHIME MODE HOME MODE AWAY MODE
3 PANIC ARMED 24-HOURS - TRIGGERS SILENT PANIC ALARM
INSTANT BURGLARY ALARM UNLESS ACTIVATED DURING AN ENTRY DELAY, THEN IT IS
9 2-BUTTON ARM/DISARM (LEFT) 2-BUTTON AUTOMATION (RIGHT) EMERGENCY (BOTH BUTTONS)
LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE † IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡ LEFT BUTTON SWITCHES SYSTEM TO OFF MODE ‡
10 2-BUTTON ARM (LEFT) 2-BUTTON DISARM (RIGHT) EMERGENCY (BOTH BUTTONS)
LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE † IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡ RIGHT BUTTON SWITCHES SYSTEM TO OFF MODE ‡
† CAN BE HOME MODE USING PROGRAMMING STEP 50 ‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51

✦ To perform any of the advanced programming
steps, the system must be in the Setup Mode. ✦ Each programming function is performed with
similar keystrokes. After the system is in Setup Mode, enter the programming step or sensor number and press HOME, then enter the new value and press AWAY. For reference, follow the fi gures next to the programming steps. ✴ If the new value is accepted, a “bing” will sound. If the
put the system into the Setup Mode. The restricted user codes cannot access Setup Mode, only Code Mode. ✴ A “Gong” and fi ve “Beeps” will sound, signaling that the
new value is not accepted, a “double buzz” will sound.
system is in Setup Mode. 3. After programming changes are complete, press the OFF key for three seconds to exit Setup Mode. ✎ NOTE: If the system is left unattended in Setup
STORES NEW VALUE
Mode, it will automatically switch back to Off Mode after three minutes.
STEP # PROGRAMMING FUNCTIONS POSSIBLE VALUES FACTORY VALUE INSTALLATION VALUE
26 EXIT DELAY 20-255 SECONDS 60
30 BURGLARY SIREN TIME 1-30 MINUTES 5
31 EMERGENCY SIREN TIME 1-30 MINUTES 5
32 FIRE SIREN TIME 1-30 MINUTES 5
40 AUTOMATION OUTPUT TIME 0-2500 SECONDS (0 = TOGGLE ON/OFF) 0
50 REMOTE ARMING MODE 2 = HOME MODE; 3 = AWAY MODE 3
51 REMOTE DISARMING MODE 0 = OFF MODE; 1 = CHIME MODE 0
61 ENTRY DELAY BEEPS 0 = OFF; 1 = ON 1
62 EXIT DELAY BEEPS 0 = OFF; 1 = ON 1
63 SILENT BURGLARY ALARM 0 = AUDIBLE; 1 = SILENT 0
64 SILENT EMERGENCY ALARM 0 = AUDIBLE; 1 = SILENT 0
65 QUICK ARMING 0 = OFF; 1 = ON 1
66 AUTO RESTORE 0 = OFF; 1 = ON 1
67 AUTO BYPASS 0 = OFF; 1 = ON 0
68 AUTOMATION MODE DURING ALARM 0 = FLASH (ENABLED BY FUNCTION 72) 1 = STEADY (ENABLED BY FUNCTION 72) 0
69 AUTOMATION BING TOME 0 = NO BINGS 1 = BINGS 1
70 REMOTE ARM/DISARM CHIRP 0 = NO CHIRPS 1 = CHIRPS (1 CHIRP = ARMED, 2 CHIRPS = DISARMED) 1
71 AUTOMATION FLASHES AFTER ALARM 0 = STANDARD 1 = FLASHING AFTER ALARM 0
0 = STANDARD 1 = AUTOMATION ACTIVE DURING ALARM (FLASH OR STEADY PROGRAMMED BY FUNCTION 68)
73 AUTOMATION ON WHILE ARMED 0 = STANDARD 1 = ON WHILE ARMED 0
74 AUTOMATION ON DURING EXIT/ENTRY 0 = STANDARD 1 = ON DURING EXIT/ENTRY DELAY 0
75 AUTOMATION POLARITY 0 = + WHEN OFF; 1 = + WHEN ON 1
92 DURESS CODE 1-5 DIGITS REMOVED
93 RESTRICTED USER CODE #1 1-5 DIGITS REMOVED
94 RESTRICTED USER CODE #2 1-5 DIGITS REMOVED
95 RESTRICTED USER CODE #3 1-5 DIGITS REMOVED
96 RESTRICTED USER CODE #4 1-5 DIGITS REMOVED
97 RESTRICTED USER CODE #5 1-5 DIGITS REMOVED
98 PAGE ALERT USER CODE 1-5 DIGITS REMOVED
99 MASTER USER CODE 1-5 DIGITS 1234
Control Panel Programming Table

NUMBER OF SENSOR TO CHANGE
✦ When a wireless sensor is programmed, the
Control Panel automatically sets it to supervised or non-supervised. The hardwire loops are always supervised for end-of-line resistor termination. ✦ The Control Panel expects hourly status
ENTERS SENSOR NUMBER
transmissions from any wireless sensor programmed as supervised. ✦ Any wireless sensor can be programmed as
supervised or non-supervised using this process. ✎ NOTE: Don't program a wireless sensor that
1 BING AND SENSOR INDICATOR LIT
doesn't send status transmissions as supervised.
NUMBER OF SENSOR TO CHANGE
✦ When a wireless sensor is programmed, the
Control Panel automatically recognizes it as manual or automatic restoring. The hardwired loops are always manual restoring. ✦ The Control Panel expects restoral signals from any
ENTERS SENSOR NUMBER
wireless sensor programmed as manual restore. ✦ Any wireless sensor can be programmed as
manual or automatic restore using this process. ✎ NOTE: Don't program a wireless sensor that doesn't
send restoral transmissions as manual restore.
ENTRY DELAY TIME
✦ The factory-set Entry Delay time is 30 seconds. STEP #25 The Entry Delay time can be adjusted from 20 to
255 seconds using this step. Write the new Entry Delay time in the User's Guide. ✎ NOTE: Don't make the Entry Delay too short. The
user may not have enough time to disarm the system before an alarm.
EXIT DELAY TIME
✦ The factory-set Exit Delay time is 60 seconds. STEP #26 The Exit Delay time can be adjusted from 20 to
255 seconds using this step. Write the new Exit Delay time in the User's Guide.
STORES VALUE - 1 BING
BURGLARY SIREN TIME
✦ The factory-set burglary siren time is fi ve minutes
(UL installation maximum). STEP #30 The burglary siren time can be adjusted from one
to 30 minutes using this step.
STORES VALUE - 1 BING
EMERGENCY SIREN TIME
✦ The factory-set emergency siren time is fi ve
minutes (UL installation maximum). STEP #31 The emergency siren time can be adjusted from
one to 30 minutes using this step.
STORES VALUE - 1 BING

✦ The factory-set fi re siren time is fi ve minutes (UL
installation maximum). STEP #32 The fi re siren time can be adjusted from one to
30 minutes using this step.
STORES VALUE - 1 BING
AUTOMATION OUTPUT TIME
✦ The factory setting causes the Automation
Output to toggle between on and off with each activation. STEP #40 The Automation Output can be programmed to
turn on, then automatically turn off after one to 2500 seconds (42 minutes), or toggle on & off, using this step.
TIME IN SECONDS 1 - 2500 0 = TOGGLE ON & OFF
REMOTE CONTROL & HARDWIRE ARMING LEVEL
✦ The factory setting causes the portable remote
controls to arm to the Away Mode. STEP #50 The portable remote controls can be changed to
arm to the Home Mode using this step. ✎ NOTE: Changing this setting will affect all the
portable remote controls used with the system and all hardwired loops programmed as arm/disarm (sensor Function #9) key stations.
REMOTE CONTROL & HARDWIRE DISARMING LEVEL
✦ The factory setting causes the portable remote
controls to disarm to the Off Mode. STEP #51 The remote controls can be changed to disarm to
the Chime Mode using this step. ✎ NOTE: Changing this setting will affect all the
portable remote controls used with the system and all hardwired loops programmed as arm/disarm (sensor Function #9) key stations.
ENTRY DELAY BEEPS
✦ The factory setting causes the keypad(s) to beep
during Entry Delays. STEP #61 The Entry Delay beeps can be silenced using
this step. ✦ With the Entry Delay beeps off, the keypad(s) will
0 FOR ENTRY BEEPS OFF 1 FOR ENTRY BEEPS ON
be silent after a delayed sensor is triggered until the Entry Delay expires, then the alarm siren will sound.
EXIT DELAY BEEPS
✦ The factory setting causes the keypad(s) to beep
during Exit Delays. STEP #62 The Exit Delay beeps can be silenced using this
step. ✦ With the Exit Delay beeps off, the keypad(s) will
0 FOR EXIT BEEPS OFF 1 FOR EXIT BEEPS ON
be silent after arming to the Away Mode until the Exit Delay expires, then a single “Gong” tone will sound.

✦ The factory setting causes audible burglary
alarms. STEP #63 The Control Panel can be programmed for silent
burglary alarms using this step.
0 FOR AUDIBLE BURGLARY 1 FOR SILENT BURGLARY
STORE - 1 BING
SILENT EMERGENCY ALARMS
✦ The factory setting causes audible emergency
alarms. STEP #64 The Control Panel can be programmed for silent
emergency alarms using this step.
STORES VALUE - 1 BING
DISABLING QUICK ARMING
✦ The factory setting allows quick arming of the
Control Panel by pressing down the mode keys for two seconds. STEP #65 The Control Panel can be programmed to not
allow quick arming using this step. If quick arming is disabled, a user code must be entered before pressing the mode buttons. ✎ NOTE: For commercial installations with retail
0 FOR QUICK ARMING OFF 1 FOR QUICK ARMING ON
traffi c, it is recommended to disable quick arming to prevent customers from arming the system. ✎ NOTE: If quick arming is disabled the Home Instant
Mode is unavailable.
✦ Bypassed sensors are ignored by the Control
Panel and cannot cause an alarm. ✦ The factory setting causes the Control Panel to
automatically restore (remove the bypass from) sensors that close. After it's restored, the sensor is ready to cause an alarm the next time it is opened. STEP #66 The Control Panel can be programmed to not
automatically restore any bypassed sensor when the sensor closes using this step. Bypassed sensors will then remain bypassed until the system is disarmed. ✎ NOTE: This setting affects all sensors.
0 FOR AUTO RESTORAL OFF 1 FOR AUTO RESTORAL ON
AUTOMATIC BYPASSING OF OPEN SENSORS
✦ The factory setting requires the user to manually
bypass any open sensors when the system is armed. ✴ If arming is attempted with open sensors, the keypad(s)
will sound fi ve two-tone Beeps and will not arm. ✦ Arming to the same mode again within fi ve
seconds will bypass any open sensors and arm the Control Panel. STEP #67 The Control Panel can be programmed to
0 FOR AUTO BYPASS OFF 1 FOR AUTO BYPASS ON
automatically bypass any open sensors when the system is armed using this step. ✎ NOTE: This setting affects all sensors.

✦ The factory setting causes the Automation
Output to fl ash if it is programmed to activate during or after an alarm. ✎ NOTE: For the Automation Output to activate
during or after an alarm, that function must be enabled with Programming Step 71 or 72. STEP #68 The output can be programmed to be a steady
STORES VALUE - 1 BING
output using this step.
✦ The factory setting causes the keypad(s) to
sound a “Bing” when the Automation Output is activated by pressing the key, or when it's triggered with a two-button remote control. STEP #69 This sound can be silenced using this step.
0 FOR BING TONE OFF 1 FOR BING TONE ON
REMOTE CONTROL & HARDWIRE ARM/DISARM CHIRP
✦ When arming with the portable remote control
or with a hardwired loop programmed as arm/ disarm (sensor Function #9), the factory setting causes the keypad(s) to “chirp” once when armed, twice when disarmed, and three times when arming with sensors bypassed. STEP #70 These chirps can be silenced using this step.
0 FOR CHIRPS OFF 1 FOR CHIRPS ON
recommended to program the Automation Output to be active when the system is armed, so a light can be triggered displaying the arming status of the system.
AUTOMATION OUTPUT ON DURING AND AFTER ALARM
✦ The factory setting causes the Control Panel's
Automation Output to activate when pressing the
key, or when it's triggered with a two-button remote control. STEP #71 The Control Panel can be programmed to
activate the Automation Output during and after any alarms as well as when normally triggered using this step. ✎ NOTE: The output will continue until the fl ashing
0 FOR STANDARD TRIGGER 1 FOR OUTPUT DURING & AFTER ALARM STORES VALUE - 1 BING
sensor status lights are cleared.
✦ The factory setting causes the Control Panel's
Automation Output to activate when pressing the
key, or when it's triggered with a two-button remote control. STEP #72 The Control Panel can be programmed to
activate the Automation Output during alarms as well as when normally triggered using this step. ✎ NOTE: The Automation Output can be programmed
0 FOR STANDARD TRIGGER 1 FOR OUTPUT DURING ALARM
to fl ash or be steady during alarm, see Programming Step 68.

✦ The factory setting causes the Control Panel's
Automation Output to activate when pressing the
key, or when it's triggered with a two-button remote control. STEP #73 The Control Panel can be programmed to
0 FOR STANDARD TRIGGER 1 FOR OUTPUT WHEN ARMED
activate the Automation Output when the system is armed as well as when normally triggered using this step.
AUTOMATION OUTPUT DURING EXIT/ENTRY DELAYS
✦ The factory setting causes the Control Panel's
Automation Output to activate when pressing the
key, or when it's triggered with a two-button remote control. STEP #74 The Control Panel can be programmed to
0 FOR STANDARD TRIGGER 1 FOR OUTPUT DURING EXIT/ENTRY DELAYS STORES VALUE - 1 BING
activate the Automation Output during the exit and Entry Delays as well as when normally triggered using this step.
✦ The factory setting causes the Control Panel's
Automation Output to provide a current limited voltage source when activated. STEP #75 The Control Panel can be programmed so the
Automation Output provides a current limited voltage source when deactivated using this step.
0 FOR VOLTAGE WHEN OFF 1 FOR VOLTAGE WHEN ON
REMOTE ACCESS PASSWORD
✦ This password is used to gain access to the Control
Panel when using the RA-2400 remote access software. The password must be 6-digits long. STEP #87 Use this step to enter a new remote access
password then log the password in the box below.
STORES PASSWORD - 1 BING REMOTE ACCESS PASSWORD:
DURESS CODE
✦ The duress code will disarm the system, without
any special indications or sounds, but will send the programmed duress code to the Central Station. The code should be two or more digits different than any user code STEP #92 Use this step to enter the duress code then log
the code in the box below.
MASTER USER CODE
✦ The master user code is 1234 when power is fi rst
applied to the Control Panel. ✦ The master user code can be changed to any
1-5 digit code. Only the master user can access Setup Mode, restricted users cannot. ✎ NOTE: For maximum security, a 3-5 digit code is
recommended. STEP #99 Use this step to enter the new master user code
then log the code in the box below.
MASTER USER CODE:

✦ The Control Panel can be programmed with fi ve
restricted user codes and one page alert user code. ✦ The restricted user codes operate the system as
usual, but cannot access Setup Mode. ✦ The restricted user codes can access a special
Code Mode that can be used to change or remove any of the fi ve restricted user codes, the page alert user code, or the duress code. ✦ The page alert user code dials the supervisory
number (programmed for a pager) when it is used to arm or disarm the system. ✦ A restricted user code is appropriate to give any
STEP #93 RESTRICTED USER CODE #1
user that should be restricted from programming the Control Panel. ✎ NOTE: For maximum security, a 3-5 digit code is
STEP #95 RESTRICTED USER CODE #3
STEP #96 RESTRICTED USER CODE #4
STEP #98 PAGE ALERT USER CODE
USER CODE THE SAME AS THE MASTER USER CODE! STEPS #93-98 Create any additional user codes using these
steps then log the codes in the boxes to the right.
STEPS #93-98 Any additional user code can be removed
from the Control Panel by entering the appropriate step number and pressing TEST. ✦ Because access to programming would be
93 = RESTRICTED CODE 1 94 = RESTRICTED CODE 2 95 = RESTRICTED CODE 3 96 = RESTRICTED CODE 4 97 = RESTRICTED CODE 5 98 = PAGE ALERT USER CODE
impossible without a master user code, it cannot be removed using these steps. The master user code can be changed using programming STEP #99. ✎ NOTE: The master user code can be set to the
factory default using the Control Panel master reset programming step, although all other system programming will be reset to factory values and all sensors programmed will be erased.
CONTROL PANEL MASTER RESET
✦ Master resetting the Control Panel will set all of the

programming options back to the factory values. The master user code will be reset to 1234. ✎ CAUTION: Master resetting the Control Panel will erase
the user codes and remove all programmed sensors. All Control Panel and communicator programming values will be reset to the factory defaults. 1. Start with the system in Test Mode (Setup Mode cannot be reached from any other mode). 2. From Test Mode, enter the master user code then press TEST. ✴ A “Gong” and fi ve “Beeps” will sound, signaling that the
USE THESE EXACT KEYSTROKES TO PERFORM A MASTER RESET ENTERS STEP NUMBER
system is in Setup Mode. 3. Enter programming STEP #999 then press TEST. 4. Enter 999 again then press TEST again. ✴ A “Bing” will sound to indicate the beginning of the reset
process. This process will take up to 10 seconds while the memory is being reset. ✦ The system will revert to the fi rst time power-
PRESS TEST, 1 BING SOUNDS, WAIT ABOUT 10 SECONDS
up condition and the new master user code will be 1234. Go to the “Basic Control Panel Programming” section of this manual to begin re- programming the system.

✦ To perform any of the advanced programming
steps, the system must be in the Setup Mode. ✦ Each programming function is performed with
similar keystrokes. After the system is in Setup Mode, enter the programming step number and press HOME, then enter the new value and press AWAY. For reference, follow the fi gures next to the programming steps. ✴ If the new value is accepted, a “Bing” will sound. If the
new value is not accepted, a “Double Buzz” will sound.
put the system into the Setup Mode. The restricted user codes cannot access Setup Mode, only Code Mode. ✴ A “Gong” and fi ve “Beeps” will sound, signaling that the
system is in Setup Mode. 3. After programming changes are complete, press the OFF key for three seconds to exit Setup Mode. ✎ NOTE: If the system is left unattended in Setup
Mode, it will automatically switch back to Off Mode after three minutes.
STEP # PROGRAMMING
POSSIBLE
FACTORY
INSTALLATION
FUNCTION
VALUES
VALUE
VALUE
76 2-WAY AUDIO 0= NONE; 1 = LISTEN; 2 = 2-WAY MANUAL; 3 = 2-WAY FULL DUPLEX 0
78 VOICE RESPONSE FROM KEYPAD SPEAKER 0 = VOICE RESPONSE DISABLED 1 = VOICE RESPONSE ENABLED 0
100 REMOTE PROGRAMMING LOCKOUT 0 = UNLOCK; 1 = LOCK 0
101 CALL LIMITER 0 = OFF; 1 = FIVE CALLS PER ARMING PERIOD 0
103 DIALING DELAY 0 = NO DELAY; 1 = 30 SECOND DELAY 0
104 DIALING METHOD 0 = TONE; 1 = PULSE 0
107 COMMUNICATOR ENABLE 0 = COMMUNICATOR OFF; 1 = COMMUNICATOR ON 0
General Communicator Programming Table

COMMUNICATOR ENABLE
✦ The factory setting for the Control Panel disables
the communicator. If the system is going to be a non-monitored, local alarm only, leave the communicator disabled. STEP #107 If the system is going to be monitored by a
Central Station, enable the communicator with this programming step.
STORES VALUE - 1 BING
2-WAY AUDIO ✦ When the Model VB-2 voice module is installed,
the communicator can provide 2-way audio capability. ✦ The audio module can be programmed for
listen-only, 2-way manual operation (using a pushbutton telephone at the Central Station), and 2-way full duplex hands free operation. ✦ Refer to the VB-2 installation instructions for
details on operating the audio module. ✎ NOTE: The Model VB-2 digital voice response
ENTERS STEP NUMBER 0 FOR NO AUDIO MONITORING 1 FOR LISTEN-ONLY 2 FOR 2-WAY MANUAL 3 FOR 2-WAY FULL DUPLEX STORES VALUE - 1 BING
module must be installed for this option to function. ✦ The factory setting for the VB-2 audio module is OFF. STEP #76 The audio module can be set for (1) listen-only, (2)
2-way manual, (3) 2-way full duplex using this step. ✎ NOTE: For safety, 2-way audio will not activate if
the system is disarmed with the duress code. ✎ NOTE:Units programmed for two-way duplex can
still be controlled manually by pressing the “1” or “3” key. In addition, the Central Station can return the unit to two-way duplex by pressing the “8” key.
✦ The Control Panel can be programmed to allow
the keypad(s) speaker to play audio produced by the VB-2 digital voice response module. ✦ This selection can also be used when a remote
speaker is connected to the Control Panel. ✦ The factory setting is to disable the keypad(s)
speaker from playing voice module audio. STEP #78 The Control Panel can be programmed to enable
0 FOR NO VOICE RESPONSE 1 FOR VOICE RESPONSE
voice module audio using this step. ✎ NOTE: Turning voice response OFF with this
programming step will only effect the audio produced by the voice module. It will not stop the keypad(s) speaker from sounding local sirens and tones. ✎ NOTE: A Model VB-2 digital voice response module
must be installed for this option to function.
✦ The factory setting for the communicator allows
remote connection to the Control Panel with Linear's RA-2400 Remote Access Software and a modem (unlocked). STEP #100 The Control Panel can be programmed to not
answer incoming calls, thereby, not allowing remote access (locked) using this step.
STORES VALUE - 1 BING

✦ The factory setting for the call limiter is OFF.
This allows the communicator to report burglary alarms, once for each sensor, as many times as they are triggered. STEP #101 The Control Panel can be programmed to only
allow fi ve burglary reports total per arming period using this step. ✎ NOTE: Sensors programmed for 24-hour functions
0 FOR OFF (UNLIMITED) 1 FOR ON (5 VIOLATIONS)
(Emergency, Panic, Fire) always send a Central Station report and always sound the local siren regardless of the Call Limiter setting.
DIALING DELAY
✦ The factory setting will cause the communicator
to dial the Central Station instantly when an alarm or supervisory event occurs. STEP #103 The communicator can be programmed to
wait 30 seconds before dialing using this step. This gives the user time to disarm the system and prevent communications in the case of a subscriber generated false alarm.
0 FOR NO DELAY 1 FOR 30 SECOND DELAY
DIALING METHOD
✦ The factory setting causes the communicator to
dial using DTMF (dual-tone multi-frequency) tone dialing. STEP #104 The communicator can be programmed to use
pulse (rotary) dialing using this step. Use this option if the telephone line in the installation does not support tone dialing.
STORES VALUE - 1 BING


to report using the 4 BY 2 FORMAT. This format allows four-digit account numbers from 0000 to 9999 and provides two-digit alarm codes. STEP #105 ADEMCO CONTACT ID can be chosen as a
reporting format using this step. This format allows 4-digit account numbers from 0000 to 9999 and provides verbose report descriptions with Ademco Contact ID compatible Central Stations.
0 FOR 4 BY 2 1 FOR ADEMCO CONTACT ID
✦ The communicator can be programmed with
three telephone numbers; primary, secondary, and supervisory. ✦ The factory setting for the communicator is to

route all calls to the primary telephone number. If communication is unsuccessful after fi ve attempts to the primary number, the secondary number will be dialed for an additional fi ve attempts. If the secondary number cannot be reached, the communicator will “sleep” for fi ve minutes before starting the call process over again. A total of four sleep cycles (50 call attempts) can occur before the communicator stops calling. STEP #86 The communicator can be programmed to report
0 FOR ALL CALLS TO PRIMARY/SECONDARY 1 FOR ALARMS ONLY TO PRIMARY/SECONDARY
supervisory events (low battery, trouble, AC failure, etc.) to the supervisory telephone number instead of the primary or secondary telephone numbers using this step.
is going to be used, the supervisory number is reserved for the pager number. DO NOT SET THE CALL ROUTING OPTION TO “1”.
routing option to “1” and remove the supervisory telephone number.
telephone numbers the same. See the FCC Telephone Rules and Regulations on the rear cover of this manual.
STEP
PROGRAMMING
POSSIBLE
FACTORY
INSTALLATION
FUNCTION
VALUES
VALUE
VALUE
0 = ALL CALLS TO PRIMARY OR SECONDARY NUMBER 1 = ALL ALARM CALLS TO PRIMARY OR SECONDARY NUMBER AND ALL OTHERS TO SUPERVISORY NUMBER
88 ACCOUNT NUMBER 4 DIGITS EMPTY
89 PRIMARY PHONE NUMBER UP TO 20 DIGITS EMPTY
90 SECONDARY PHONE NUMBER UP TO 20 DIGITS EMPTY
91 SUPERVISORY/PAGER PHONE NUMBER UP TO 20 DIGITS EMPTY
PRESSING THE (A) KEY INSERTS A 1-SECOND DELAY THE [FIRE] KEY INSERTS A 5-SECOND DELAY FOR ALL PHONE NUMBERS ⇒ ⇒ ⇒ THE [CHIME] KEY INSERTS A “*” THE (A) KEY INSERTS A “#” IF IT IS THE LAST DIGIT OF THE PHONE NUMBER
105 REPORTING FORMAT 0 = 4 BY 2; 1 = ADEMCO 0
108 REPORT SYSTEM TROUBLE 0 = NO; 1 = YES 0
110 REPORT FORCE ARMING 0 = NO; 1 = YES 0
111 OPEN/CLOSE 0 = NO; 1 = YES; 2 = MASTER PAC ONLY 0
113 POINT ID REPORTING FOR 4 BY 2 FORMAT 0 = NO; 1 = YES 1
Communicator Reporting Option Table
#

✦ The account number entered for the
communicator must be 4-digits long. ✦ The factory setting for the account number is
0000. STEP #88 Enter an account number from 0000 to 9999
using this step.
PRIMARY TELEPHONE NUMBER
✦ The primary Central Station telephone number
can be up to 20-digits long. ✦ Digits 0-9 can be used. ✦ Delays and special characters can be entered in
the telephone number (see below). STEP #89 Enter the primary telephone number using this
step.
SECONDARY TELEPHONE NUMBER
✦ The secondary Central Station telephone
number can be up to 20-digits long. ✦ Digits 0-9 can be used. ✦ Delays and special characters can be entered in
the telephone number (see below). STEP #90 Enter the secondary telephone number using this
number, enter step number 90 then press TEST.
✦ The supervisory Central Station or pager
telephone number can be up to 20-digits long. ✦ Digits 0-9 can be used. ✦ Delays and special characters can be entered
in the telephone number (see below). If this is a pager number, enter enough delays for the phone to answer. Then, enter the number to be dialed. ✦ End a pager number with the completion
UP TO 20 DIGITS FOR THE SUPERVISORY/PAGER NUMBER STORES VALUE - 1 BING
character (usually a pound (#) character). STEP #91 Enter the supervisory or pager telephone number
number, enter step number 91 then press TEST.
✦ When creating telephone numbers with
programming Steps 89, 90, & 91, use the following keys to add dialing delays or special characters. ✦ Press the key to place a 1-second dialing delay at the start or anywhere in the middle of the telephone number. ✦ Pressing the key as the last digit of the telephone number will place a pound character at the end of the telephone number. ✦ Press the FIRE key to place a 5-second dialing
ADDS A 1-SECOND DELAY (START OR MIDDLE OF NUMBER)
ADDS A 5-SECOND DELAY (ANYWHERE IN NUMBER)
ADDS A STAR ( ) CHARACTER (ANYWHERE IN NUMBER)
delay anywhere in the telephone number. ✦ Press the CHIME key to place a star character anywhere in the telephone number.

✦ The factory setting does not report Control Panel
trouble events to the Central Station. STEP #108 The communicator can be programmed to
report Control Panel trouble events using this step. These include all conditions that light the keypad(s) BATTERIES or TROUBLE indicator. It also includes low Control Panel backup battery.
0 FOR NO CONSOLE TROUBLE 1 FOR CONSOLE TROUBLE
REPORT FORCE ARMING
✦ The factory setting does not send force arming
reports. STEP #110 The communicator can be programmed to report
force arming anytime the Control Panel is armed with one or more bypassed sensors using this step. ✦ The factory set reporting code for force arming is
“65” (Code 574 with Ademco). ✎ NOTE: If force arming is enabled, and the Control
0 FOR NO FORCE ARMING RPTS. 1 FOR FORCE ARMING RPTS.
Panel is force armed (armed with an open sensor) remotely by telephone, or with the RA-2400 Remote Access software, the caller will be disconnected if the communicator is enabled.
OPENING AND CLOSING REPORTS
✦ The factory setting does not send opening and
closing reports. STEP #111 The communicator can be programmed to send
an opening report when the system is disarmed, and a closing report when the system is armed for all users, or just the master user using this step. ✎ NOTE 1: For commercial installations with retail
traffi c using opening and closing reports, it is recommended to disable quick arming to prevent customers from arming the system. ✎ NOTE 2: The reporting codes are fi xed for opening
0 FOR NO OPEN/CLOSE REPORTS 1 FOR O/C RPTS. FOR ALL USERS 2 FOR O/C RPTS. FROM MASTER USER ONLY
and closing. A unique code is reserved for the master user code and each of the fi ve restricted user codes. ✎ NOTE 3: Arming or disarming with the page
alert user code dials the supervisory number, no opening or closing report is sent.
✦ The factory setting enables Point ID and allows
the communicator to send two-digit alarm and trouble codes for each sensor. The individual sensor that causes an alarm or trouble report can be identifi ed at the Central Station. STEP #113 Point ID can be disabled using this step. The
Central Station will only receive general alarm and trouble reports.
0 FOR GENERAL REPORTS ONLY 1 FOR POINT ID REPORTING

COMMUNICATOR REPORTING CODES ✦ The 4 by 2 two-digit communicator reporting

code for each event has a factory set value. These values may be customized to fi t the specifi c installation and the reporting requirements of the Central Station monitoring the system. ✦ If Point ID reporting is enabled (the factory
default setting), each sensor can report a unique alarm and trouble code. ✦ If Point ID is disabled, the “general” reporting
codes for each event type will be used. ✦ Each programming function is performed with
similar keystrokes. After the system is in Setup Mode, enter the programming step number and press HOME, then enter the new value and press AWAY. For reference, follow the fi gures next to the programming steps. ✴ If the new value is accepted, a “Bing” will sound. If the
new value is not accepted, a “Double Buzz” will sound. ✦ Making a value 0 causes the event not to
communicate to the Central Station. ✎ NOTE: The reporting codes are fi xed for opening

and closing. A unique code is reserved for the master and the fi ve restricted user codes. See the Opening & Closing Reporting Codes Table.
✦ Use program Steps #201 - 206 to change the

communicator reporting codes when Point ID is disabled. ✦ Refer to the General Reporting Codes table to
view/edit the reporting codes for each of the fi ve events. The factory settings are listed, along with a blank area to write in the new installation values. STEPS #201-206
Any value from 0-99 can be programmed for each event using these steps (enter “0” to stop an event from reporting). ✎ NOTE: Be careful not to duplicate codes unless the
Central Station requires specifi c codes for certain types of events.

STEP # PROGRAMMING FUNCTION POSSIBLE 4 BY 2 VALUES FACTORY 4 BY 2 VALUES INSTALLATION 4 BY 2 VALUE
201 GENERAL FIRE REPORT CODE 0 - 99 1
202 GENERAL EMERGENCY REPORT CODE 0 - 99 2
203 GENERAL SILENT PANIC REPORT CODE 0 - 99 3
204 GENERAL BURGLARY REPORT CODE 0 - 99 4
206 GENERAL TROUBLE REPORT CODE 0 - 99 6
General Reporting Codes Table

✦ Refer to the System Reporting Codes table to
view/edit the reporting codes for the keypad FIRE and EMERGENCY buttons and for each of the three Control Panel conditions. The factory settings are listed, along with a blank area to write in the new installation values. STEPS #261-266
0 - 99 FOR SYSTEM REPORTING CODE
Any value from 0-99 can be programmed for each event using these steps (enter “0” to stop an event from reporting).
FORCE ARMING REPORTING CODE
✦ The factory set reporting code for force arming is
“65” (Code 574 with Ademco). STEP #258 Any value from 0-99 can be programmed for this
event using this step (0 = no report). ✎ NOTE: For force arming reporting, force arming
reports must be enabled. See Page 41.
STORES VALUE - 1 BING
DURESS REPORTING CODE
✦ The factory set reporting code for Duress is “66”
(Code 121 with Ademco). STEP #259 Any value from 0-99 can be programmed for this
event using this step (0 = no report). ✎ NOTE: For duress code reporting a keypad duress
code must be programmed. See Page 34.
STORES VALUE - 1 BING
SYSTEM REPORTING CODES
STEP # PROGRAMMING FUNCTION POSSIBLE 4 BY 2 VALUES
4 BY 2 VALUE
258 FORCE ARMING REPORT CODE 0 - 99 65 574
259 DURESS REPORT CODE 0 - 99 66 121
261 SYSTEM FIRE REPORT CODE 0 - 99 68 110
262 SYSTEM EMERGENCY REPORT CODE 0 - 99 69 120
263 SYSTEM TEST/CANCEL REPORT CODE 0 - 99 70 406
264 SYSTEM LOW BATTERY RESTORAL REPORT CODE 0 - 99 71 R302
265 SYSTEM LOW BATTERY CODE 0 - 99 73 E302
System Reporting Codes Table

MASTER USER CODE1 74 82 R401 C000 E401 C000
RESTRICTED USER CODE #1 75 83 R401 C001 E401 C001
RESTRICTED USER CODE #2 76 84 R401 C002 E401 C002
RESTRICTED USER CODE #3 77 85 R401 C003 E401 C003
RESTRICTED USER CODE #4 78 86 R401 C004 E401 C004
RESTRICTED USER CODE #5 79 87 R401 C005 E401 C005
PAGE ALERT USER CODE (DIALS PAGE NUMBER ONLY, NO CODES REPORTED)
REMOTE/HARDWIRE ARM (SENSOR FCN. 9) & QUICK ARM 81 R407 C007
Opening & Closing Reporting Codes Table

4 BY 2 FORMAT POINT ID ALARM REPORT CODES ✦ Refer to the 4 by 2 Format Point ID Reporting
Code table to view/edit the alarm reporting codes for each of the 24 sensors. The communicator will send these codes if Point ID is enabled and any sensor triggers an alarm. The factory settings are listed, along with a blank area to write in the new installation values. ✦ Use program Steps #210 - 233 to change the
4 by 2 Point ID alarm reporting codes. ✎ NOTE: Be careful not to duplicate codes unless the
Central Station requires specifi c codes for certain types of sensors. STEPS #210-233
Any value from 0-99 can be programmed for each event using these steps (enter “0” to stop an event from reporting).
4 BY 2 FORMAT POINT ID TROUBLE REPORT CODES ✦ Refer to the 4 by 2 Format Point ID Reporting
Code table to view/edit the trouble reporting codes for each of the 24 sensors. The communicator will send these codes if Point ID is enabled and any sensor has a low battery or trouble condition. The factory settings are listed, along with a blank area to write in the new installation values. ✦ Use program Steps #234 - 257 to change the
0 - 99 FOR SENSOR TROUBLE CODE
4 by 2 Point ID trouble reporting codes. ✎ NOTE: Be careful not to duplicate codes unless the
Central Station requires specifi c codes for certain types of sensors. STEPS #234-257
Any value from 0-99 can be programmed for each event using these steps (enter “0” to stop an event from reporting).


STEP # PROGRAMMING FUNCTION POSSIBLE 4 BY 2 VALUES FACTORY 4 BY 2 VALUE INSTALLATION 4 BY 2 VALUE
210 SENSOR 1 ALARM REPORT CODE 0 - 99 11
211 SENSOR 2 ALARM REPORT CODE 0 - 99 12
212 SENSOR 3 ALARM REPORT CODE 0 - 99 13
213 SENSOR 4 ALARM REPORT CODE 0 - 99 14
214 SENSOR 5 ALARM REPORT CODE 0 - 99 15
215 SENSOR 6 ALARM REPORT CODE 0 - 99 16
216 SENSOR 7 ALARM REPORT CODE 0 - 99 17
217 SENSOR 8 ALARM REPORT CODE 0 - 99 18
218 SENSOR 9 ALARM REPORT CODE 0 - 99 19
219 SENSOR 10 ALARM REPORT CODE 0 - 99 20
220 SENSOR 11 ALARM REPORT CODE 0 - 99 21
221 SENSOR 12 ALARM REPORT CODE 0 - 99 22
222 SENSOR 13 ALARM REPORT CODE 0 - 99 23
223 SENSOR 14 ALARM REPORT CODE 0 - 99 24
224 SENSOR 15 ALARM REPORT CODE 0 - 99 25
225 SENSOR 16 ALARM REPORT CODE 0 - 99 26
226 SENSOR 17 ALARM REPORT CODE 0 - 99 27
227 SENSOR 18 ALARM REPORT CODE 0 - 99 28
228 SENSOR 19 ALARM REPORT CODE 0 - 99 29
229 SENSOR 20 ALARM REPORT CODE 0 - 99 30
230 SENSOR 21 ALARM REPORT CODE 0 - 99 31
231 SENSOR 22 ALARM REPORT CODE 0 - 99 32
232 SENSOR 23 ALARM REPORT CODE 0 - 99 33
233 SENSOR 24 ALARM REPORT CODE 0 - 99 34
234 SENSOR 1 TROUBLE REPORT CODE 0 - 99 41
235 SENSOR 2 TROUBLE REPORT CODE 0 - 99 42
236 SENSOR 3 TROUBLE REPORT CODE 0 - 99 43
237 SENSOR 4 TROUBLE REPORT CODE 0 - 99 44
238 SENSOR 5 TROUBLE REPORT CODE 0 - 99 45
239 SENSOR 6 TROUBLE REPORT CODE 0 - 99 46
240 SENSOR 7 TROUBLE REPORT CODE 0 - 99 47
241 SENSOR 8 TROUBLE REPORT CODE 0 - 99 48
242 SENSOR 9 TROUBLE REPORT CODE 0 - 99 49
243 SENSOR 10 TROUBLE REPORT CODE 0 - 99 50
244 SENSOR 11 TROUBLE REPORT CODE 0 - 99 51
245 SENSOR 12 TROUBLE REPORT CODE 0 - 99 52
246 SENSOR 13 TROUBLE REPORT CODE 0 - 99 53
247 SENSOR 14 TROUBLE REPORT CODE 0 - 99 54
248 SENSOR 15 TROUBLE REPORT CODE 0 - 99 55
249 SENSOR 16 TROUBLE REPORT CODE 0 - 99 56
250 SENSOR 17 TROUBLE REPORT CODE 0 - 99 57
251 SENSOR 18 TROUBLE REPORT CODE 0 - 99 58
252 SENSOR 19 TROUBLE REPORT CODE 0 - 99 59
253 SENSOR 20 TROUBLE REPORT CODE 0 - 99 60
254 SENSOR 21 TROUBLE REPORT CODE 0 - 99 61
255 SENSOR 22 TROUBLE REPORT CODE 0 - 99 62
256 SENSOR 23 TROUBLE REPORT CODE 0 - 99 63
257 SENSOR 24 TROUBLE REPORT CODE 0 - 99 64
4 by 2 Format Point ID Reporting Code Table

LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twelve (12) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear's normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer's warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
FIRE EVACUATION PLANNING For systems that include fi re protection, UL requires that the following information be available to the users of the system.
✶ Draw up a fl oor plan showing two exits for each room.
The following procedures are to be discussed with the family:
➀ Status of bedroom doors. ➁ Familiarity with alarm signals. ➂ Testing of door during a fi re and use of alternate escape route if door
is hot to touch. ➃ Crawling and holding breath. ➄ Escape fast. No stopping for packing. ➅ Meet at designated outdoor spot. ➆ Emphasize that no one is to return to a burning house. ➇ Fire department notifi cation from a neighbor's phone. ➈ Periodic rehearsal is to be conducted.
WIRELESS PRODUCT NOTICE Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling. However, there are some limitations which must be observed.
INDUSTRY CANADA NOTICES NOTICE: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5. NOTICE: The Industry Canada label identifi es certifi ed equipment. This certifi cation means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certifi ed equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particulary important in rural areas. CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range. ✶ A receiver cannot respond to more than one transmitted signal at a
time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. ✶ Changes or modifi cations to the device may void FCC compliance. ✶ Infrequently used radio links should be tested regularly to protect
against undetected interference or fault. ✶ A general knowledge of radio and its vagaries should be gained prior
to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.
FCC NOTICE This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
✶ Relocate the Control Panel away from the TV/radio receiver. ✶ Plug the Control Panel into a different wall outlet so that the Control
Panel is on a different branch circuit. ✶ Re-orient the TV/radio antenna. ✶ If necessary, the user should consult the dealer or an experienced
radio/television technician for additional suggestions.
FCC TELEPHONE RULES AND REGULATIONS The FCC requires that this alarm dialer system not make more than 15 repetitive dialing attempts to a single telephone number. There are no limitations when the calls are made sequentially to two or more alternative numbers, or when these calls are spaced 10 minutes apart to a single number. The FCC Rules and Regulations do not specify the re-attempt period as this can vary for specifi c applications. When setting this period, take into consideration local, interstate, foreign and special network call completion characteristics, network processing time, a suffi cient number of rings and busy/don't answer modes.
Copyright © 2008 Linear LLC 217703 D
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.