EN
Linear logo
Official user manual

Linear DUAL 824

48 pages·4 MB·Home Security System·PDF·ENDEFRITNLJA
Linear DUAL 824
Table of Contents 80 sections DUAL 824 · SUPERVISED WIRELESS SECURITY CONTROL PANEL · Installation & Programming Instructions · INTRODUCTION · … ShowHide
Page 1 of the Linear DUAL 824 user manual — Installation & Programming Instructions
Page 1 · click to enlarge
Page 1

DUAL 824

SUPERVISED WIRELESS SECURITY CONTROL PANEL

Linear DUAL 824 — DUAL 824 diagram (page 1)
Fig. 1
Linear DUAL 824 — DUAL 824 diagram (page 1)
Fig. 2

Installation & Programming Instructions

USA & Canada (800) 421-1587 & (800) 392-0123

(760) 438-7000 - Toll Free FAX (800) 468-1340

www.linearcorp.com

Page 2 of the Linear DUAL 824 user manual — MADE IN CHINA 454
Page 2 · click to enlarge
Page 2

INTRODUCTION

CONGRATULATIONS for selecting Linear's DUAL 824 Security System. The Model DUAL 824P Control Panel and the Model DUAL 824KP Keypad incorporate many advanced and sophisticated features. The system can be expanded and customized to fi t the installation's specifi c needs. The DUAL 824P Control Panel and its accessories are designed and manufactured by the oldest wireless security company in North America. You can look ahead to many years of reliable service with this Control Panel and its accessories. Many insurance companies offer discounts on homeowners and renters policies when a security system is installed. Discount credits vary with different companies and generally increase in savings with an increase in the level of protection. Inform the user to ask their insurance agent about savings available. The DUAL 824P Control Panel is UL Listed. For a UL smoke alarm system, there must be at least one smoke detector programmed into the Control Panel to meet National Fire Protection Association (NFPA) Rule 72 Chapter 2 and UL 217 requirements. Many insurance companies require these conditions to be met to qualify for a discount. Only use the Model DXS-73 smoke detector with this Control Panel for a UL smoke alarm system. NOTE: Some cities and municipalities may require an alarm system permit. Check with the local authorities before installing this system. In this manual, the bullets preceding the text help to defi ne the information. For example:

DUAL 824 SYSTEM

Linear DUAL 824 — DUAL 824 SYSTEM diagram (page 2)
Fig. 3

CONTROL PANEL MODEL DUAL 824P

KEYPAD MODEL DUAL 824KP

UL Listed as a Single Station Smoke Detector Accessory, also suitable as a Household Burglar- Alarm System Control Unit. UL Category CCN UTGT & NBSX

✦ This symbol indicates a feature. ✴ This symbol is for lit indications or system

sounds. ✎ This symbol is for important notes.

LINEAR LLC RESIDENTIAL SECURITY RECEIVER MODEL: DUAL 824 PART # SSC00056 FREQUENCY: 315 MHz POWER SUPPLY: 16 VAC, 1.25A

USOC JACKS: RJ31X, RJ38X

WARNING:

CAUTION: IMPORTANT:

ANTENNA

TELEPHONE

1. MISCONNECTIONS MAY CAUSE DAMAGE TO CONTROL PANEL ELECTRONICS 2) DO NOT REVERSE BATTERY LEADS 3) TO PREVENT RISK OF ELECTRICAL SHOCK, DISCONNECT TELCO JACK BEFORE SERVICING THIS CONTROL PANEL 4) FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSES
1. NO USER SERVICABLE PARTS INSIDE 2) RISK OF FIRE AND ELECTRICAL SHOCK, ROUTE WIRES AWAY FROM INTERNAL COMPONENTS 3) REMOVE AC POWER BEFORE CONNECTING TRANSFORMER, BATTERY, OR REPLACING FUSES
1. USE UL LISTED CABLE FOR ALL CONNECTIONS 2) WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM 3) DO NOT CONNECT AC POWER TO A RECEPTACLE CONTROLLED BY A SWITCH 4) CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM HEADQUARTERS OR A CENTRAL STATION SHALL BE PERMITTED ONLY WITH THE APPROVAL OF THE LOCAL AUTHORITY HAVING JURISDICTION. THE BURGLAR ALARM SIGNAL SHALL NOT BE CONNECTED TO A POLICE EMERGENCY NUMBER.

ANT

To internal antenna wires or to Model LA-P external antenna kit

RED

RING

SHIELD

GREEN

TIP

BACKUP BATTERY

This device complies with FCC Part 15 and IC Canada Rules and Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Complies with Part 68, FCC Rules. FCC Registration Number: EF4HKG-31823-AL-E Ringer Equivalence Number: 1.7B

GRAY

RED (+)

CONNECT TO 12 VDC/4AH GEL CELL BATTERY

R1

Battery wires Charging voltage13.8 VDC

Fire protection must follow NFPA Standard No. 72 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Printed information describing proper installation, operation, testing, maintenance, evacuation planning, and repair service is to be provided with this equipment.

BROWN

BLACK (-)

T1

life should exceed 3 years

AUXILIARY FUSE TYPE 2AG, 1 AMP

BATTERY FUSE TYPE 2AG, 3 AMP

HARDWIRED LOOP INPUTS OUTPUTS KEYPAD XFRMR

LOOP

1 COM LOOP

2 LOOP

3 COM LOOP

4 LOOP

5 COM LOOP

6 LOOP

7 COM LOOP

8 H/A

H/A

RLY COM

RLY

RLY

+12 VDC

KPD

KPD

KPD CLK

KPD DAT

KPD SPK+

KPD SPK -

AC AC

N/C

N/O

CANADIAN REGULATORY INFORMATION

IC ID 1078-102-556A Complies with IC RSS 210 En conformité avec IC CNR 210.

LOOP 1

LOOP 2

LOOP 3

LOOP 4

LOOP 5

LOOP 6

LOOP 7

LOOP 8

ORANGE

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

ALARM RELAY Rated 12 volts, 1 amp maximum

AUXILIARY

RED

BLACK

WHITE

AUTOMATION

POWER OUTPUT 12 VDC at 1 Amp maximum

DUAL 824KP HARDWIRED KEYPAD

MODEL RSM-2 VOICE RESPONSE

EXTERNAL SIREN

switched +12 VDC, 40 mA

12 VDC at 1 Amp maximum

ONE OR TWO UNITS ALLOWED

SPEAKER 8 Ohm - 2 Watts

TRANSFORMER

N.O. N.O.

N.O. N.O.

N.O. N.O.

N.O. N.O.

16VAC, 1.25A Connect to 24hr. 120VAC, 60 Hz Outlet

Warranty Expiration Date:

See instructions for output options

KEYPAD WIRING 4-conductor 22 AWG wire Up to 100 feet for all keypads used allowed

2.2k E.O.L. RESISTOR

2.2k E.O.L. RESISTOR

2.2k E.O.L. RESISTOR

2.2k E.O.L. RESISTOR

2.2k E.O.L. RESISTOR

2.2k E.O.L. RESISTOR

2.2k E.O.L. RESISTOR

2.2k E.O.L. RESISTOR

FOR INSTALLATION INSTRUCTIONS, REFER TO THE MANUAL SUPPLIED WITH THIS PRODUCT

LOOP RESPONSE TIME400 mS MAXIMUM RECOMMENDED LOOP LENGTH: 500 FEET

To any COM terminal

(760) 438-7000 • FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123

MADE IN CHINA 454

DUAL 824 WIRING DIAGRAM

Toll Free FAX (800) 468-1340

www.linearcorp.com

Show 7 more labels / short text on this page
Incoming Phone Line · Local Telephones · Normal battery · + · + · OUTPUT Current limited · voltage source
Page 3 of the Linear DUAL 824 user manual — INTRODUCTION
Page 3 · click to enlarge
Page 3
Page 3 of the Linear DUAL 824 user manual — INTRODUCTION
Page 4 of the Linear DUAL 824 user manual — SENSOR
Page 4 · click to enlarge
Page 4

1. THE DUAL 824 SECURITY SYSTEM

Linear DUAL 824 — 1. THE DUAL 824 SECURITY SYSTEM diagram (page 4)
Fig. 4

DXS-73 SMOKE DETECTOR

DXS-91 GLASS BREAK DETECTOR †

DXS-54

PIR

DXS-81 BILL TRAP †

CONTROL

DXS-31 DOOR/WINDOW

DXS-32 MINI DOOR/WINDOW

† NOTEThese accessories

PANEL

DXT-41 & DXT-42

DXS-62A REMOTE

DXT-61A REMOTE †

DXT-21 & DXT-23

REMOTES

REMOTES †

are not listed by UL.

SENSOR

SENSOR

CONTROL PANEL The DUAL 824P Control Panel is the heart of the system. It monitors all of the system's wireless sensors, hardwired loops, and controls the alarm sirens and Model DUAL 824KP hardwired keypads. The Control Panel constantly monitors the condition of the system's sensors and hardwired contacts, displaying which protected doors and windows are open or closed. If an alarm occurs, the keypads display which sensor(s) caused it. When a sensor has a low battery, the keypads display which sensor needs a new battery. Sensors that send hourly status transmissions keep the Control Panel informed of their operating condition. Up to eight different custom user codes can be used to operate the system. For security, a user code must be entered to disarm (turn off) the system. The system can be armed (turned on) by entering a user code, or with the unique “Quick Arm” feature. The fi ve restricted user codes and the special page alert user code can only arm and disarm the system, no programming changes (except changing user and duress codes) are allowed. The master user code is allowed to program the Control Panel, and a duress code can be selected for emergency disarming of the system with a duress report to the Central Station. The page alert user code can dial a pager number to inform the pager wearer when the system is disarmed. The Control Panel's memory will retain the user codes and all of the system's programming, even during a total power loss. An optional backup battery can be installed to power the system during short power failures. The built-in digital communicator connects the Control Panel to a Central Alarm Monitoring Station through the telephone. With a monitored system, the central station can dispatch authorities in case of burglary, fi re or other emergency. The central station can also call family, friends, neighbors, or anyone else designated on a custom call list. System arming (closing) and disarming (opening) reports by user can also be sent. Each sensor can report directly to the Central Station using the digital communicator's Point ID feature. If a sensor triggers an alarm or experiences supervisory trouble, a unique report code can be sent for immediate identifi cation of the event.

The optional Model VB-2 digital voice response module can be installed in the Control Panel. The VB-2 module provides three exciting features: 2-way audio monitoring capability at the Central Station through the communicator, local voice prompts from the keypad's speaker (with Model RSM-2 speaker/microphone kit installed), and voice prompted remote system control using in-house or off-site pushbutton telephones. The system has 24-hour capabilities that are always ready to operate, even when the system is disarmed. They can be triggered by buttons on the hardwired keypads, a wireless keypad, portable remote controls, carbon monoxide detectors, and smoke detectors. Pressing the EMERGENCY or FIRE button for two seconds will cause an immediate siren and call the central station. IMPORTANT: For personal emergency use only. Not for use as a UL Listed Medical Alert System. The Control Panel's Environmental feature is active 24-hours and can be triggered with sensors connected to devices such as water fl ow detectors, over/under temperature sensors, fl ood sensors, etc. The Environmental feature activates the chime annunciator without sounding the siren. The Environmental feature does not send communicator reports. An Automation Output in the Control Panel provides an easy way to connect external devices to the Control Panel. The output is fully programmable to activate on a variety of conditions, such as when the system is armed, during alarms, and during exit/entry delays. The Automation Output can connect to lighting control modules, relays, noisemakers, and indicators. The Control Panel's and wireless keypad's

key and any system sensors can control the Automation Output. The Control Panel can be programmed locally using its own keypad or remotely, over the telephone, using Linear's Model RA-2400 Remote Access software program. The RA-2400 upload/download program is a Windows™ application that runs on a personal computer and communicates with the Control Panel through a modem, connected directly to the panel, or through the telephone line.

Page 5 of the Linear DUAL 824 user manual — DXS-91‡
Page 5 · click to enlarge
Page 5

DOOR/WINDOW SENSORS The DXS-31 and DXS-32 sensors monitor doors and windows. They send radio signals to the Control Panel. One type of signal is sent when the door or window is opened, and a different type of signal is sent when the door or window is closed. If the system is armed, a sensor can trigger the Control Panel's burglary siren when its door or window is opened. Both sensors are supervised, send hourly status reports, and monitor their battery condition.

PANIC BUTTONS The DXT-21, DXS-21 single-button, and DXT-23, DXS-23 two-button transmitters can be used as portable “panic buttons”. Pressing the front or top button on the DXT-21 or DXS-21 at any time will trigger the emergency siren. Pressing both front buttons simultaneously on the DXT-23 or DXS-23 at any time will trigger the emergency siren. These transmitters can be programmed to activate various other system functions. The DXT-21 and DXT-23 transmitters are not supervised. The DXS-21 and DXS-23 transmitters are supervised. The DXS-62A transmitter is typically used as a portable “panic button”. Pressing the button on a DXS-62A at any time will trigger the emergency siren. This transmitter can send hourly status signals and low battery signals if the battery is low.

Linear DUAL 824 — 1. THE DUAL 824 SECURITY SYSTEM diagram (page 5)
Fig. 5

WIRELESS KEYPAD The DXS-10 wireless keypad is used to operate the system remotely. It can be placed in a convenient spot so the user doesn't have to go to the hardwired keypad to operate the system. The wireless keypad can also trigger the emergency or fi re siren and actuate the Automation Output. Pressing will cause the hardwired keypad(s) to sound Beeps corresponding to the current operating mode. The DXS-10 is supervised, it sends hourly status reports and monitors its battery condition. IMPORTANT: For personal emergency use only. Not for use as a UL Listed Medical Alert System.

DXT-21‡ DXS-21‡ DXT-23‡ DXS-23‡ DXS-62A

BILL TRAP The DXS-81 bill trap can be used with the Control Panel in non- UL small commercial hold-up installations. The unit is concealed in a cash drawer under a stack of currency, with a single “bait” bill secured in its money clip. During a hold-up, the cashier removes the stack of currency along with the “bait” bill. When a “bait” bill is removed, the transmitter sends a signal to the Control Panel. Four additional signals are sent within the fi rst minute after the “bait” bill is removed. When the “bait” bill is replaced, a restore signal is sent. The DXS-81 is supervised, it can send hourly status reports (optional) and monitors its battery condition.

Linear DUAL 824 — DXT-21‡ DXS-21‡ DXT-23‡ DXS-23‡ DXS-62A diagram (page 5)
Fig. 6

SMOKE DETECTOR The DXS-73 is a high quality smoke detector with a built-in radio transmitter. As soon as smoke is detected, the unit will sound its local noisemaker. Then, 20 seconds after the local noisemaker sounds, the transmitter sends an alarm signal to the Control Panel. The alarm signal will be repeated every 20 seconds as long as smoke is still present. A restoral signal will be sent when the smoke detection chamber clears. The DXS-73 is supervised, it sends hourly status reports, and monitors its battery condition.

DXS-81‡

PASSIVE INFRARED MOTION DETECTOR The DXS-54 is a passive infrared (PIR) motion detector with a built-in radio transmitter. The PIR detects motion in its detection pattern by measuring the infrared emission levels of objects that it “sees”. If the infrared levels change quickly, as when a person moves across the detection pattern, the PIR will recognize the change as an intrusion and send an alarm signal to the Control Panel. An alarm will be triggered if the system is in the Away Mode. The DXS-54 is supervised, it sends hourly status reports and monitors its battery condition.

DXS-73

☞ NOTE: A Model DXS-73 Smoke Detector is required to create a UL Listed smoke alarm system. See Page 26 for details on adding a smoke detector sensor to the system.

REMOTE CONTROLS The DXT-41, DXT-61 single-button and DXT-23, DXT-42 multi-button remote controls can be used to remotely arm and disarm the system. The DXT-42’s left button will arm and the right button will disarm the system. Pressing both buttons simultaneously will trigger the emergency siren. Alternately the Control Panel can be programmed to respond to the DXT-42 by arming and disarming with the left button, and activating the automation output with the right button. These transmitters can also be programmed to activate various other Control Panel zones. These transmitters are not supervised.

DXS-54

DXT-41

DXT-42

DXT-61‡

GLASS BREAK DETECTOR The DXS-91 is a glass break detector with an audio sound discriminator and a built-in radio transmitter. The unit “listens” for the sound of breaking glass. When glass breakage is detected, the unit sends an alarm signal to the Control Panel. The DXS-91 is supervised, it sends hourly status reports and monitors its battery condition.

‡ NOTEThese accessories not listed by UL

DXS-91‡

Page 6 of the Linear DUAL 824 user manual — ES
Page 6 · click to enlarge
Page 6

2. SECURITY SYSTEM FLOOR PLAN

EXAMPLE SYSTEM

✦ The example shows a typical DUAL 824 system. ✦ Any or all of the accessories shown can be used. ✦ A total of 24 sensors can be used with each

Control Panel. Each wireless sensor, hardwired loop, and wireless keypad used occupies a sensor location.

DESIGN THE INSTALLATION

1. Draw a fl oor plan for the installation. 2. Consider the security needs of the premises. 3. Determine which doors and windows are vulnerable to intrusion. 4. Figure which interior areas an intruder might go to if unlawful entrance is gained. 5. Indicate locations for door/window sensors, interior motion detectors, wireless and hardwired keypads, glass break detectors and external siren speakers. 6. Decide on a centralized location for the security Control Panel.

ES

Linear DUAL 824 — ES diagram (page 6)
Fig. 7

CP - CONTROL PANEL HK - HARDWIRED KEYPAD S - DOOR/WINDOW SENSOR WK - WIRELESS KEYPAD MD - MOTION DETECTOR ES - EXTERNAL SIREN SD - SMOKE DETECTOR CO - CARBON MONOXIDE DETECTOR GB - GLASS BREAK SENSOR MS - HARDWIRED MAGNETIC SWITCH

Example Residential Security System Floor Plan

Page 7 of the Linear DUAL 824 user manual — KEYPAD
Page 7 · click to enlarge
Page 7

3. OVERVIEW OF KEYPADS

HARDWIRED KEYPAD

✦ One or two hardwired keypads can be used for

controlling the system. ✦ Three system status indicators:

READY, ARMED, & TROUBLE ✦ Three system supervisory indicators:

POWER, BATTERIES, & RADIO ✦ Five system mode indicators:

HARDWIRED

KEYPAD

OFF, CHIME, HOME, AWAY & TEST ✦ 24 system sensor indicators. ✦ Location inside beauty cover for supplied sensor

identifi cation labels. ✦ Press to activate the automation output. ✦ Pressing clears the keypad. ✦ Pressing for two seconds sounds the mode Beeps from the hardwired keypad(s).

✔ Off Mode: 1 “Gong”. ✔ Chime Mode: 1 “Gong” & 1 “Beep”. ✔ Home Mode: 1 “Gong” & 2 “Beeps”. ✔ Away Mode: 1 “Gong” & 3 “Beeps”. ✔ Test Mode: 1 “Gong” & 4 “Beeps”. ✦ Emergency and fi re alarm can be triggered from

the keypad at any time. ✎ UL NOTE: For personal emergency use only. Not

Linear DUAL 824 — HARDWIRED diagram (page 7)
Fig. 8

for use as a UL Listed Medical Alert System.

WIRELESS KEYPAD

✦ For controlling the system remotely. ✦ Green operation light. ✦ Internal 9-volt battery is monitored by the Control

KEYPAD

Panel. ✦ Keypad's beeper will buzz during transmissions

when the battery is low. ✦ Up to 3 years battery life (depends on frequency

of activation). (UL tested for 1 year minimum.) ✦ Sends hourly status reports to the Control Panel. ✦ Press to activate the automation output. ✦ Pressing clears the keypad. ✦ Pressing for two seconds sounds the mode Beeps from the hardwired keypad(s).

ABOUT SENSOR STATUS SUPERVISION All DXS Format sensors transmit hourly status reports. All DXT Format sensors do not transmit hourly status reports. Both sensor formats can be used with the system. When a sensor is programmed into the Control Panel, the system will set the sensor as non-supervised or supervised. Sensors set as non-supervised are not expected to send hourly status reports. Sensors set as supervised are expected to send hourly status reports. If a status report is not received in 8 hours from a sensor set as supervised, the RADIO indicator will fl ash. When sensors are programmed into the Control Panel, ALL STATIONARY SENSORS ARE SET AS SUPERVISED, ALL PORTABLE SENSORS ARE SET AS NON-SUPERVISED. If stationary DXT Format sensors have been programmed into the Control Panel, be sure to change their setting to non-supervised to prevent RADIO indications. This will not prevent low battery monitoring. If portable DXS Format sensors have been programmed into the Control Panel, and the installation requires supervision for specifi c portable sensor(s), change the selected portable sensors setting to supervised. After programming the sensors, if changes are required, refer to “Changing a Sensors Supervision” on Page 30 for details on changing the way a sensor’s supervision is set.

✔ Off Mode: 1 “Gong”. ✔ Chime Mode: 1 “Gong” & 1 “Beep”. ✔ Home Mode: 1 “Gong” & 2 “Beeps”. ✔ Away Mode: 1 “Gong” & 3 “Beeps”. ✔ Test Mode: 1 “Gong” & 4 “Beeps”. ✦ Emergency and fi re alarm can be triggered from

the wireless keypad at any time. ✎ UL NOTE: For personal emergency use only. Not

for use as a UL Listed Medical Alert System.

Page 8 of the Linear DUAL 824 user manual — 6 MICROPHONE (OPTIONAL)
Page 8 · click to enlarge
Page 8

4. HARDWIRED KEYPAD FEATURES

7 SENSOR STATUS INDICATORS

Linear DUAL 824 — 7 SENSOR STATUS INDICATORS diagram (page 8)
Fig. 9

★ Blacked-out sensor status indicators are only visible when lit. ★ Indicate the status of each of the system's wireless sensors and hardwired

loops. ★ Indicators show which doors and windows are open. ★ Indicators fl ash to display sensors that have caused an alarm. ★ Stick-on labels are provided to identify the custom sensor locations.

8 SYSTEM STATUS INDICATORS

★ Shows the current status of the system.

READY LIGHT

★ Lights when all system sensors are closed. ★ Shows that the system is ready to be armed. ★ The system can be armed without the READY indicator being lit, if sensors are

bypassed either manually or automatically.

ARMED LIGHT

★ Blinks during the exit delay. ★ Lights when the system is fully armed.

TROUBLE LIGHT

★ Lights when the system has detected supervisory trouble. ★ Supervisory trouble can be caused by power, sensor low battery, or sensor radio

supervision conditions. ★ Press for one second then view the system supervisory and status indicators to determine the origin of the trouble.

1 BEAUTY COVER

★ The beauty cover snaps open and shut to hide the keypad’s keys, mode and

9 MODE BUTTONS

★ Used to operate the system.

supervisory indicators, and the sensor location labeling area.

OFF

2 KEYPAD

★ Backlit keys for easy viewing in low light conditions. ★ For entering the user's user code (numerically or alphabetically). ★ Used when programming system options. ★ Press to activate the Automation Output. ★ Press to clear keypad if the wrong key is pressed. ★ Press for two seconds to view sensor battery and supervisory status (see BATTERIES and RADIO indicator description).

★ Off Mode disarms the system. ★ Switching to Off Mode stops the alarm siren.

✓ Multiple Beeps sound and sensor status indicators fl ash if an alarm has

occurred. ☞ Multiple Beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.

CHIME

★ Chime Mode disarms the system. ★ Switching to Chime Mode stops the alarm siren.

3 24-HOUR BUTTONS ★ Pressing FIRE for two seconds sounds the fi re siren and sends a “fi re” message

✓ Multiple Beeps sound and sensor status indicators fl ash if an alarm has

to a central monitoring station through the digital communicator (if the system is monitored). ★ Pressing EMERGENCY for two seconds sounds the emergency siren and sends

occurred. ☞ Multiple Beeps mean caution. AN INTRUDER MAY STILL BE PRESENT. ★ Chime Mode is for monitoring doors and windows.

✓ Use this mode as an “automatic door chime” when at home. ✓ Opening any protected door or window causes the keypad(s) to “ding-dong”.

an “emergency” message to a central monitoring station through the digital communicator (if the system is monitored). ★ Both work even when system is disarmed. ★ IMPORTANT: For personal emergency use only. Not for use as a UL Listed

HOME

★ Home Mode arms the perimeter sensors, but not the interior sensors.

✓ Use this mode when anyone is staying behind. ✓ Interior motion detectors and interior door sensors are not armed. ✓ Home secure mode makes all delayed perimeter sensors instant. ✓ Secure exit mode starts an exit delay while remaining in Home Mode. ✓ Re-entering during the exit delay restarts the exit delay (one time only).

Medical Alert System.

4 SYSTEM SUPERVISORY INDICATORS

★ Shows the current status of the system.

POWER LIGHT

★ Glows when AC power is on. ★ Blinks when AC power is off and backup battery is installed. ★ Blinks when the backup battery is low, recharging or missing. ★ Off when AC power is off and no backup battery is installed (system disabled).

AWAY

★ Away Mode arms the entire system.

✓ Use this mode when leaving home. ✓ Door sensors set for delayed will have a time delay that allows the user to

BATTERIES LIGHT

leave and enter the premises without sounding the alarm. ✓ Re-entering during the exit delay restarts the exit delay (one time only). ✓ Entry Delay Beeps warn the user to disarm the system before the siren

★ Blinks when one or more sensors have a low battery. ★ Press for two seconds to view sensor status. Sensor status indicator for any sensor with a low battery will light along with the BATTERIES indicator. ★ Switch to Test Mode after replacing the sensor battery and completely test the

starts.

system (see Test Mode). Switching to Test Mode clears the low battery indication.

TEST

★ Test Mode is for testing the system sensors.

RADIO LIGHT

✓ All sensor status lights blink when the Test Mode is entered. ✓ Each sensor status light will stop blinking when its sensor is tested. ★ Hold the TEST button down to test all of the keypad's indicator lights.

★ Blinks when one or more sensors have not reported status during the eight hour

status time period. ★ Press for two seconds to view sensor status. Sensor status indicator for any sensor that has not reported in will light along with the TROUBLE indicator. ★ Switch to Test Mode after servicing the sensor and completely test the system

10 SOUNDER ★ Makes unique sounds for burglary, fi re and emergencies. ★ Alarm sirens stop automatically after fi ve minutes. ★ Sounds advisory tones to confi rm keystrokes from the keypad. ★ Sounds mode selection tones. ★ Sounds alarm memory tones. ★ Beeps when Automation Output is activated. ★ The Control Panel has terminals available for an external siren.

(see Test Mode). Switching to Test Mode clears the trouble indication.

5 MODE INDICATORS

★ The indicators next to the mode keys light to show the current system mode. ★ HOME indicator will blink during Secure Exit and Home Instant modes. ★ AWAY indicator will blink during the exit delay in the Away Mode.

6 MICROPHONE (OPTIONAL)

11 SPEAKER (OPTIONAL)

★ Location for the high sensitivity microphone included with the Model RSM-2

★ Location for the speaker included with the Model RSM-2 speaker/microphone

speaker/microphone kit. ★ Detects room audio when communicator is reporting to the Central Station

kit. ★ Sounds voice operating prompts and audio from the Central Station (Model

in 2-way audio mode (Model VB-2 digital voice response module and RSM-2 speaker/microphone kit must be installed).

VB-2 digital voice response module and Model RSM-2 required).

Page 9 of the Linear DUAL 824 user manual — 7 WALL-MOUNT KEYHOLE SLOTS
Page 9 · click to enlarge
Page 9

5. CONTROL PANEL FEATURES

Linear DUAL 824 — 5. CONTROL PANEL FEATURES diagram (page 9)
Fig. 10

1 BATTERY FUSE

8 DIGITAL VOICE RESPONSE MODULE (OPTIONAL)

★ Type 2AG, 3-amp fuse for the backup battery. ★ If the keypad's POWER light is fl ashing and the optional backup battery is

★ The Model VB-2 gives the Control Panel's digital communicator listen-only,

manual 2-way and full duplex 2-way audio capability with the Central Station. ★ The module allows remote command of the system using a standard pushbutton

installed and charged, check this fuse. ✎ WARNING: For continued protection against the risk of fi re, replace only

telephone, on or off site. ★ The module provides optional voice prompts from the keypad(s) (Model RSM-2

with the same type and rating of fuse.

2 CONDUIT KNOCKOUTS

speaker/microphone kit required for each keypad).

★ Four cabinet knockouts are provided for wiring using conduit. ★ The 3/4" knockouts fi t standard 3/4" conduit fi ttings.

9 ANTENNA KNOCKOUT

★ A cabinet knockout is provided for mounting an external antenna connector. ★ For an external antenna, use Linear's Model LA-P antenna kit. ★ The antenna kit can also be used to connect the Control Panel to co-ax for a

3 WIRING ACCESS SLOT

★ Provides access for wiring through a hole in the mounting wall. ★ Route cables for power, telephone, external speaker, etc. through this slot.

remote antenna.

10 ANNUNCIATOR VOLUME CONTROL ★ Varies the volume of the advisory tones that come from the keypad(s) speaker

4 MAIN TERMINAL BLOCK

★ Terminals for hardwired loop inputs. ★ Terminals for Automation Output to connect to an automation controller. ★ Terminals for external relay output for “dry” contacts (Form C, normally open/

when the Model RSM-2 speaker/microphone kit is installed in the keypad. ★ Does not affect keypad's sirens (they are always full volume).

normally closed, 1 amp @ 24 volts maximum). ★ Terminals for fused auxiliary 12 volt output and common ground. ★ Terminals for connection to one or two Model DUAL 824KP keypads. ★ Terminals for connection to the plug-in AC transformer.

11 RADIO TEST POINTS

★ Used to monitor the Control Panel's radio receiver during troubleshooting. ★ Provides connection for an audio amplifi er to listen to the receiver's output. ★ Helpful to determine sources of radio interference.

5 AUXILIARY FUSE

12 ANTENNA TERMINALS ★ Antenna and shield (ground) terminals for receiving signals from the system's

★ Type 2AG, 1-amp fuse. ★ Protects the auxiliary power output and siren driver circuit. ★ Fuse will blow when load exceeds 1 amp total. ✎ WARNING: For continued protection against the risk of fi re, replace only

sensors. ★ Pre-wired to the Control Panel's internal wire dipole antenna. ★ Alternately connects to the Model LA-P local whip and remote antenna kit.

with the same type and rating of fuse.

13 OPTIONAL BACKUP BATTERY ★ Space for 12-volt, 4 amp/hour backup battery. (Highly recommended.) ★ Backup battery is automatically charged and monitored by the Control Panel. ★ Backup battery can power the Control Panel for up to 6 hours. ★ UL NOTE: Normal estimated battery life should be 3 to 4 years.

6 TELEPHONE TERMINAL BLOCK

★ Provides telephone connections for the digital communicator. ★ Provides telephone connection for voice prompted telephone remote control

(optional VB-2 digital voice response module required). ★ Provides seized ring and tip connections for local telephone instruments.

14 REMOVABLE CABINET COVER ★ The cabinet cover can be removed for easy system wiring and setup. ★ Two screws secure cabinet cover when closed. ★ An optional cabinet lock can be installed for additional security.

Communicator will disconnect local telephones while on-line.

7 WALL-MOUNT KEYHOLE SLOTS

★ Four slots used when mounting Control Panel to the wall. ★ Used as a template for the Control Panel when it is mounted to the wall.

Page 10 of the Linear DUAL 824 user manual — EXTERNAL ANTENNA
Page 10 · click to enlarge
Page 10

6. CONTROL PANEL INSTALLATION

SYSTEM LOCATION

✎ NOTEWireless sensor signals must be able to

reach the Control Panel.

✔ Try to centrally locate the Control Panel. ✔ Keep Control Panel away from large metal

USE THE CASE BOTTOM AS A TEMPLATE TO MARK THE FOUR KEYHOLE MOUNTING HOLES

Linear DUAL 824 — SYSTEM LOCATION diagram (page 10)
Fig. 11

appliances. ✔ Maximum recommended sensor range is 400

feet (system tested at 1000 feet). ✎ NOTE: If you don't use the wireless keypad, a

hardwired keypad should be easily accessible to the usual entrance.

FOR RECESSED WIRING, MARK WIRING SLOT, THEN CUT OUT HOLE WITH DRYWALL SAW

✔ When the Control Panel is set in the Away

Mode, the user has 30 seconds to switch to Off Mode before the burglary siren sounds. ✎ NOTE: Make sure a hardwired keypad is in a place

where the alarm can be heard during the night hours.

✔ Optional remote external sirens (up to 150

feet from the Control Panel) can be used to make alarms louder and remote the sound location. 1. Locate the Control Panel near a 115 VAC outlet that's not controlled by a light switch. 2. Locate the Control Panel near a telephone outlet (if using the digital communicator).

WALL MOUNTING

Linear DUAL 824 — WALL MOUNTING diagram (page 10)
Fig. 12

FOR CONDIUT WIRING, PUNCH OUT REQUIRED KNOCKOUTS AND INSTALL 3/4" CONDUIT HUBS IN HOLES

1. Use the Control Panel's case bottom as a template and mark the locations for the four mounting screws. 2. Mark the wiring access slot if the wiring is being routed from behind the cabinet. 3. Use a hole saw to cut out the location for the wiring access slot (if used) or punch out selected cabinet wiring knockouts for conduit wiring. 4. Use four screws and appropriate screw anchors to mount the unit to the wall.

EXTERNAL ANTENNA

✦ Linear's Model LA-P antenna kit can be used

with the DUAL 824P Control Panel to replace the standard internal antenna. ✦ The antenna can be mounted on the cabinet,

or the kit can be used to connect to co-ax for a remote antenna. 1. Remove the two standard white antenna wires attached to the ANT and SHIELD terminals. 2. Punch out the antenna knockout. 3. Mount the antenna connector in the antenna knockout. 4. Route the antenna co-ax down to the Control Panel's antenna connector. 5. Connect the antenna's co-ax center conductor to the ANT terminal. 6. Connect the antenna's co-ax shield to the SHIELD terminal. 7. Route the two antenna ground wires as shown.

Linear DUAL 824 — EXTERNAL ANTENNA diagram (page 10)
Fig. 13

PUNCH OUT ANTENNA KNOCKOUT AND INSTALL LA-P ANTENNA CONNECTOR INTO HOLE

INSTALL THE WHIP ANTENNA AND ROUTE THE TWO GROUND WIRES AS SHOWN

CONNECT CO-AX SHIELD TO SHIELD TERMINAL AND CO-AX CENTER CONDUCTOR TO ANT TERMINAL

Page 11 of the Linear DUAL 824 user manual — WIRING HARNESS CONNECTOR
Page 11 · click to enlarge
Page 11

KEYPAD SELECT

HARDWIRED KEYPAD INSTALLATION

TWIST SCREWDRIVER IN SLOTS TO OPEN THE KEYPAD CASE

JUMPER SET TO "KEYPAD 1"

Linear DUAL 824 — JUMPER SET TO "KEYPAD 1" diagram (page 11)
Fig. 14

SOUNDER JUMPER

SET TO "ON"

✦ One or two Model DUAL 824KP keypads can be

used with the DUAL 824P Control Panel (one keypad is included in the DUAL 824 system package). ✦ The keypad is supplied with a short wiring

DEFAULT JUMPER POSITIONS

harness and connector. 1. Use a fl at blade screwdriver to open the keypad case. Identify the keypad internal components. 2. Set the keypad select jumper to KEYPAD 1 if this is the fi rst, or only, keypad installed. Set the jumper to KEYPAD 2 if this is the second keypad installed. 3. For a silent keypad, set the SOUNDER jumper to OFF. 4. Select an indoor location with easy wiring access to the Control Panel and use the keypad's mounting plate as a template to mark the mounting holes for the keypad. 5. Route 4-conductor 22 AWG (or larger) wire from the Control Panel to the keypad(s). Up to 100 feet of wire total can be used with this system. If installing two keypads, each keypad can be “home-run” or “daisy-chained”. ✎ Note: If a Model VB-2 voice response module is

SOUNDER JUMPER CAN BE SET TO "OFF" SET KEYPAD SELECT JUMPER TO "KEYPAD 2" IF THIS IS THE 2ND KEYPAD

ALTERNATE JUMPER POSITIONS

Linear DUAL 824 — ALTERNATE JUMPER POSITIONS diagram (page 11)
Fig. 15

MOUNT KEYPAD INDOORS AT A CONVENIENT HEIGHT AND LOCATION FOR THE USERS

USE THE MOUNTING PLATE AS A TEMPLATE TO MARK SCREW LOCATIONS

USE SCREWS AND ANCHORS OR APPROPRIATE FASTENERS TO AFFIX MOUNTING PLATE

going to be used with the system, in addition to the keypad’s four wires, route 2-conductor shielded cable and 2-conductor 22 AWG wire from the Control Panel to the keypad(s) for the keypad’s microphone and speaker. When using two keypads and two microphones, each shielded microphone cable must be home run to the VB-2 terminal block. 6. If using the VB-2 voice response module, refer to the instructions supplied with the Model RSM-2 speaker/microphone kit for details on installing and wiring the keypad’s speaker and/or microphone. 7. Connect the 4-conductor wire to the Control Panel's keypad terminals, noting wire colors. 8. Noting wire colors, connect the keypad's wiring harness to the wire from the Control Panel. 9. Plug the keypad wiring harness into the keypad connector and snap the keypad case closed.

THE MOUNTING PLATE IS ALSO DESIGNED TO BE ATTACHED TO A SINGLE-GANG OUTLET BOX

ROUTE 4-CONDUCTOR 22 AWG WIRE OR LARGER FROM CONTROL PANEL TO KEYPAD

DUAL 824P CONTROL PANEL

WHITE

KPD DAT

KPD CLK

ORANGE

KPD

BLACK

RED

KPD

TO DUAL 824KP

KEYPAD

ROUTE WIRING CONNECTOR THROUGH MOUNTING PLATE HOLE

IF THE RSM-2 SPEAKER/MICROPHONE KIT IS GOING TO BE USED, RUN AN ADDITIONAL PAIR FOR THE SPEAKER AND A SHIELDED PAIR FOR THE MICROPHONE

WIRING HARNESS CONNECTOR

ALIGN TOP OF CASE FIRST, THEN SNAP BOTTOM TOGETHER

INSERT CONNECTOR INTO THE KEYED SOCKET ON THE KEYPAD UNTIL IT SNAPS TOGETHER

Page 12 of the Linear DUAL 824 user manual — LOOP
Page 12 · click to enlarge
Page 12

HARDWIRED LOOP WIRING

RUN LOOP WIRING BETWEEN THE CONTROL PANEL AND THE REMOTE HARDWIRED SENSORS

✦ The DUAL 824 supports up to eight normally

open/closed hardwired loops each with 2.2K end-of-line resistor supervision. ✦ Each hardwired loop that is wired and

4-CONDUCTOR FOR HARDWIRED

INFRAREDS

programmed uses one sensor location. ✦ Each hardwired loop can be programmed to any

2-CONDUCTOR FOR MAGNETIC

CONTACTS

sensor number. ✦ Each hardwired loop can be programmed as any

RUN 4-CONDUCTOR WIRE TO POWERED DEVICES

sensor type, including arm/disarm toggle. ✦ Four COM terminals are shared as loop returns

RUN 2-CONDUCTOR WIRE TO DEVICES NOT POWERED FROM THE CONTROL PANEL

for the eight loops. ✦ Each hardwired loop has a 400 millisecond

MAIN TERMINAL BLOCK

LOOP

1 COM LOOP

2 LOOP

3 COM LOOP

4 LOOP

N/O COM

8 H/A

H/A

RLY COM

RLY

RLY

+12 VDC

N/C

response time. ✎ NOTEFor UL installations, use UL Listed cable for
Linear DUAL 824 — MAIN TERMINAL BLOCK diagram (page 12)
Fig. 16

all hardwired loop wiring. 1. Route wiring from the Control Panel to each hardwired switch contact, sensor, or device. Route the wires through the wiring slot or through a knockout for conduit wiring. ✎ NOTE: Maximum recommended hardwired loop

USE +12 VDC AND ANY COM TERMINAL TO POWER EXTERNAL DEVICES (1 AMP MAX.)

2.2K END-OF-LINE RESISTOR FOR EACH LOOP USED NORMALLY CLOSED SWITCHES (CONTACTS)

length is 500 feet (250' out, and 250' back) for each loop. Maximum loop resistance (excluding the EOL resistor) is 100 ohms. 2. Connect the loop wires to LOOP # and COM terminals. For powered devices connect power wires to +12 VDC and any COM terminal. 3. On the sensor end, connect each normally closed sensor in series with the loop wires. Connect each normally open sensor in parallel with the loop wires. See wiring fi gure. 4. After the last sensor on the loop, connect a 2.2K end-of-line resistor across the loop. ✎ NOTE: Before the hardwired loops will function,

Linear DUAL 824 — MAIN TERMINAL BLOCK diagram (page 12)
Fig. 17

CONNECT EACH HARDWIRED INPUT TO A LOOP AND COM TERMINAL

FOR POWERED DEVICES, WIRE POWER LEADS TO +12 VDC AND ANY COMMON TERMINAL (OBSERVE POLARITY)

they will need to be programmed. This will be covered in the Basic Control Panel Programming section of this manual.

ARM/DISARM KEY STATION WIRING

MAIN TERMINAL BLOCK

✦ Any of the hardwired loops can be used with a

LOOP

1 COM LOOP

2 LOOP

3 COM LOOP

4 LOOP

N/O COM

8 H/A

H/A

RLY COM

RLY

RLY

N/C

momentary keyswitch to arm and disarm the system. 1. Connect the loop as shown to the keyswitch and end-of-line resistor. 2. Connect an LED indicator from the switch plate to the H/A- and H/A+ terminals. 3. When programming the system, set the loop sensor function to “Type 9, Arm/Disarm Toggle” and set the Automation output to “Active while Armed”.

Linear DUAL 824 — LOOP diagram (page 12)
Fig. 18

+ · +

Page 13 of the Linear DUAL 824 user manual — BLUE, ORANGE BLACK, AND YELLOW NOT USED
Page 13 · click to enlarge
Page 13

EXTERNAL ALARM SIREN CONNECTION

✦ An external siren alerts occupants and neighbors

with a loud siren during alarm. ✦ Use a 12 volt, 1 amp maximum rated weather-

EXTERNAL

ALARM

resistant horn speaker with a built-in siren driver. Do not use a plain speaker without a siren driver. ✎ NOTE: Connection of an electromechanical bell or

SIREN

motor bell is not recommended because of the radio interference generated when the bell is running.

MAIN TERMINAL BLOCK

✎ UL NOTEOnly one external siren is allowed in UL

N/O COM

LOOP

8 H/A

H/A

RLY COM

RLY

RLY

+12 VDC

N/C

installations. 1. Mount the external siren. 2. Route the wires from the external siren to the Control Panel. 3. Route the siren wires up through the wiring access slot or through a knockout when using conduit. 4. Connect a jumper wire from the +12 VDC terminal to the RLY COM terminal. 5. Connect the positive siren wire to the RELAY N/O terminal. 6. Connect the negative siren wire to one of the COM terminals. ✎ NOTE: The relay contacts are isolated. Use the

Linear DUAL 824 — N/O COM diagram (page 13)
Fig. 19

INSTALL WIRE JUMPER TO PROVIDE POWER TO RELAY CONTACTS

EXTERNAL SIREN

12 VDC 1 AMP MAXIMUM

Linear DUAL 824 — EXTERNAL SIREN diagram (page 13)
Fig. 20

CONNECT EXTERNAL SIREN TO ALARM RELAY TERMINALS

RLY N/O & RLY COM terminals alone to switch an externally powered load.

INSTALL A JUMPER WIRE BETWEEN THE +12 VDC AND RLY COM TERMINALS

TELEPHONE LINE CONNECTION

✦ Connect the Control Panel to the telephone

line if the system is monitored, requires 2-way audio, telephone remote command, or for remote programming with RA-2400 software. ✦ Telephone RING & TIP terminals are for

TELEPHONE TERMINAL BLOCK

connection to the incoming telephone line. ✦ Seized telephone ring & tip (R1 & T1) are for

SEIZED TIP (T1) LINE RING (R)

LINE TIP (T)

SEIZED RING (R1)

Linear DUAL 824 — SEIZED TIP (T1) LINE RING (R) diagram (page 13)
Fig. 21

connection to local telephone sets. When the communicator activates, all the local telephone sets will be disconnected to prevent an off-hook telephone on the premises from blocking the communicator call. 1. Install a USOC RJ31-X or RJ38-X jack to the telephone system near the Control Panel. 2. Route an appropriate modular telephone line cord from the jack to the Control Panel. 3. Route the line cord through the Control Panel's wiring access slot or through a knockout for conduit wiring. 4. Connect the incoming telephone line wires to the Control Panel's telephone terminal block TIP and RING terminals. 5. Connect the local telephone set wires to the Control Panel's telephone terminal block T1 and R1 terminals. ✦ When directly connecting (without a telephone line)

BLUE, ORANGE BLACK, AND YELLOW NOT USED

Linear DUAL 824 — BLUE, ORANGE BLACK, AND YELLOW NOT USED diagram (page 13)
Fig. 22

CONNECT INCOMMING AND OUTGOING TELEPHONE LINES TO THE TELEPHONE TERMINAL BLOCK

to the DUAL 824 with the RA-2400 remote access software (Version 1.3 or later), disconnect the incoming telephone line and connect the modem to the panel's TIP and RING terminals (with the modem's red & green phone line wires). Press the EMERGENCY key while in Test Mode to cause the panel to connect to the modem.

+

Page 14 of the Linear DUAL 824 user manual — BE SURE CONTROL PANEL POWER IS DISCONNECTED!
Page 14 · click to enlarge
Page 14

AUTOMATION OUTPUT CONNECTION

Linear DUAL 824 — AUTOMATION OUTPUT CONNECTION diagram (page 14)
Fig. 23

MAIN TERMINAL BLOCK

✦ The Control Panel provides a Automation Output

LOOP

8 H/A

H/A

RLY COM

to control lights, devices and appliances. ✦ Automation Output can connect to most popular

ANY SENSOR CAN BE PROGRAMMED TO TOGGLE THE AUTOMATION OUTPUT

home automation devices and other simple electronic devices (see fi gure). ✦ Press to turn the Automation Output on, press again to turn it off.

THE POSITIVE H/A TERMINAL PROVIDES +12 VOLTS DC AND IS CURRENT LIMITED AT 40 MILLIAMPS MAXIMUM

PRESS THE KEY ON ANY SYSTEM KEYPAD TO TOGGLE THE AUTOMATION OUTPUT

A

THE NEGATIVE H/A TERMINAL WILL SWITCH TO GROUND WHEN AUTOMATION OUTPUT IS ACTIVATED

✦ There are many programmable options for the

Automation Output. ✦ The Automation Output can be programmed for

a variety of useful functions, such as: fl ashing during alarm, fl ashing after an alarm, on while armed, or, on during exit/entry delays. ✦ See the “Advanced Programming” section of this

EXAMPLE AUTOMATION OUTPUT HOOK-UPS

H/A + H/A - H/A + H/A - H/A + H/A -

POWER SOURCE LIGHT EMITTING DIODE (L.E.D.)

manual for details on changing the function of the Automation Output.

470 OHM

X-10 BURGLAR ALARM INTERFACE (CAN CONTROL HOUSE LIGHTS THROUGH X-10 SYSTEM)

VOICE RESPONSE MODULE

YOUR LOAD

X-10 LINEAR RB-90 RELAY MODULE

✦ The DUAL 824P circuit board has a plug-in

location for a Model VB-2 voice response module. ✦ The VB-2 module allows remote command

VB-2 VOICE RESPONSE MODULE

of the system locally and remotely through a pushbutton telephone. ✎ NOTE: The following two features require a Model

Linear DUAL 824 — VB-2 VOICE RESPONSE MODULE diagram (page 14)
Fig. 24

RSM-2 speaker/microphone kit installed in the keypad. ✦ The VB-2 module can sound voice prompts

through a speaker installed in the keypad. ✦ The VB-2 module supports listen-only audio,

two-way manual audio, and full duplex two-way audio communication with the Central Station through a microphone installed in the keypad. ✎ NOTE: Refer to the VB-2 instructions for details on

operating the voice response module.

Voice Response Module Installation

PANEL CONNECTOR

1. Identify the audio module components, noting the terminal block positions. 2. Connect shielded microphone wire to the VB-2 MICROPHONE COMMON (for shield) and MICROPHONE #1 (for center conductor) terminals. Connect the other end of the wire’s shield to the BLACK, and center conductor to the RED microphone wires in the keypad. 3. If using two keypads for audio monitoring, repeat Step 2 for the second keypad, except connect the center conductor to the VB-2 MICROPHONE #2 terminal. 4. WITHOUT POWER APPLIED TO THE CONTROL PANEL, plug the voice response module into the sockets on the Control Panel's circuit board. Be sure the arrows on the module board are pointing up. 5. Connect 2-conductor wire from the Control Panel’s KPD SPK+ and KPD SPK- terminals to the two speaker wires in the keypad.

BE SURE CONTROL PANEL POWER IS DISCONNECTED!

CAREFULLY PLUG VOICE MODULE INTO THE TWO CIRCUIT BOARD SOCKETS BE SURE ALL PINS ARE ALIGNED BOARD ARROWS POINT UP

Linear DUAL 824 — BE SURE CONTROL PANEL POWER IS DISCONNECTED! diagram (page 14)
Fig. 25

+ · Programmable Options

Page 15 of the Linear DUAL 824 user manual — BACKUP BATTERY INSTALLATION
Page 15 · click to enlarge
Page 15

CONTROL PANEL POWER CONNECTION

MAIN TERMINAL BLOCK

✦ The Control Panel is powered by a low voltage

XFRMR KEYPAD

plug-in transformer. ✦ Use up to 25 feet of 20 AWG or larger

KPD SPKAC AC KPD

KPD CLK

KPD DAT

KPD SPK +

Linear DUAL 824 — KPD SPKAC AC KPD diagram (page 15)
Fig. 26

2-conductor wire to connect the transformer to the Control Panel. 1. Route the power wires from the plug-in transformer to the Control Panel. 2. Connect the wires to the transformer terminals (do not plug the transformer in until the wiring is complete). 3. Route the power wires through the Control Panel's wiring access slot or through a knockout for conduit wiring. 4. Connect the power wires from the transformer to the Control Panel's main terminal block AC & AC terminals. 5. Plug transformer into an unswitched AC outlet. 6. Secure transformer with screw to prevent unplugging.

16 VAC, 28 VA BE SURE TO SELECT AN UN-SWITCHED AC OUTLET FOR THE TRANSFORMER

Linear DUAL 824 — KPD SPKAC AC KPD diagram (page 15)
Fig. 27

CONNECT TRANSFORMER WIRES TO THE AC TERMINALS ON THE MAIN TERMINAL BLOCK

Linear DUAL 824 — KPD SPKAC AC KPD diagram (page 15)
Fig. 28

PLUG TRANSFORMER INTO 115 VAC OUTLET THAT IS NOT CONTROLED BY A LIGHT SWITCH

BACKUP BATTERY INSTALLATION

BE SURE RED WIRE ATTACHES TO POSITIVE (+) TERMINAL, AND BLACK WIRE ATTACHES TO NEGATIVE (-) TERMINAL

✦ A 12-volt backup battery may be installed and is

AFTER ALL WIRING IS COMPLETE, CONNECT THE BACKUP BATTERY

highly recommended. ✦ The backup battery will power the system for up

Linear DUAL 824 — BACKUP BATTERY INSTALLATION diagram (page 15)
Fig. 29

to 6 hours during AC power loss. ✦ The backup battery is automatically charged by

the Control Panel when AC power is present. ✦ A low backup battery will cause the keypad's

POWER indicator to fl ash as it is being charged. 1. Position the battery as shown. 2. Connect the black battery lead to the negative battery terminal. 3. Connect the red battery lead to the positive battery terminal. ✎ WARNING: DO NOT REVERSE THE BATTERY

LEADS! THE BATTERY FUSE WILL BLOW.

Page 16 of the Linear DUAL 824 user manual — STORES NEW CODE
Page 16 · click to enlarge
Page 16

7. BASIC CONTROL PANEL PROGRAMMING

✦ In a new installation, when power is fi rst

applied the system's master user code is “1234”.

CREATE THE MASTER USER CODE

ENTERING

SETTING A NEW MASTER

✎ NOTELocal programming must be entered on

SETUP

MODE

USER CODE

the system's hardwired keypad, not on a wireless keypad. 1. Press (clears keypad if any other keys have been pressed). 2. Place the system in Test Mode (enter 1234 and press TEST. ✴ A “gong” and four “beeps” will sound. 3. Enter the Setup Mode from Test Mode, enter 1234 then press TEST again. ✴ A “gong” and fi ve “beeps” will sound. The system is now

START IN OFF MODE

START IN SETUP MODE

CLEARS KEYPAD

PROGRAMMING STEP #99

DEFAULT MASTER USER CODE

in Test Mode. 4. Enter 99 then press HOME. 5. Enter any combination of 1-5 digits for the master user code, then press AWAY. ✎ NOTE: For maximum security, a three to fi ve digit

NEW MASTER USER CODE

1 GONG & 4 BEEPS (TEST MODE)

code is recommended. 6. Press and hold the OFF key for 3 seconds to exit program mode. 7. Test the new master user code by entering it then pressing TEST. 8. Log the master user code in the box below.

STORES NEW CODE

DEFAULT MASTER USER CODE

HOLD FOR 3 SECONDS TO EXIT SETUP

DONE

MASTER USER CODE:

1 GONG & 5 BEEPS (SETUP MODE)

✎ NOTEThe master user code can be used to enter

Setup Mode. The restricted user codes cannot. To create restricted user codes, see the “Advanced Programming” section of this manual.

Page 17 of the Linear DUAL 824 user manual — 1 BING AND SENSOR INDICATOR LIGHTS
Page 17 · click to enlarge
Page 17

PROGRAM THE HARDWIRED LOOPS

START IN TEST

✦ Each hardwired loop used must be programmed

into the Control Panel's memory. ✦ Each hardwired loop programmed uses one of

the twenty four available sensor locations. 1. Start with the system in Test Mode (enter the master user code and press TEST). 2. Enter the Setup Mode from Test Mode, enter the master user code then press TEST again. ✴ A “Gong” and fi ve “Beeps” will sound. The system is now

MASTER USER CODE

1 GONG & 5 BEEPS (SETUP MODE)

in Setup Mode. ✴ The sensor status indicators will light for any sensors

already programmed into the Control Panel. 3. Enter programming Step #301-308 (301=loop 1, 302=loop 2, etc.) for the hardwired loop desired. 4. Press HOME to select step. 5. Enter an unused sensor number from 01-24 for the loop (you must enter two digits, example: 5 = 05). 6. Press AWAY to store. ✴ A single “Bing” tone will sound and the sensor status

STEP #301-308 FOR LOOP #1-8

SENSOR NUMBER (01-24) FOR LOOP

indicator for that sensor will stay lit. A double “Buzz” will sound if that sensor location is already in use. 7. Repeat Steps 3-6 to enable all of the hardwired loops used. ✎ NOTE: The default sensor function for the

STORES LOOP SENSOR NUMBER 1 BING

hardwired loops is Perimeter (Type 5). Any sensor function can be selected for each hardwired loop, refer to the “Customizing the System” section of this manual.

DONE

PROGRAM THE WIRELESS SENSORS

✦ Each wireless sensor used must be programmed

into the system’s memory. See the next two pages for details on activating different models of transmitters. ✦ Each wireless sensor programmed uses one of

START IN TEST

the twenty four available sensor locations. 1. Start with the system in Test Mode (enter any user code and press TEST). 2. Enter the Setup Mode from Test Mode, enter the master user code then press TEST again. ✴ A “Gong” and fi ve “Beeps” will sound. The system is now

MASTER USER CODE

1 GONG & 5 BEEPS (SETUP MODE)

in Setup Mode. ✴ The sensor status indicators will light for any sensors

programmed into the Control Panel. 3. Enter an unused sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✴ The sensor indicator light will fl ash for the sensor number

NEW SENSOR NUMBER

SENSOR INDICATOR FLASHES

selected. 4. Activate the sensor by sending a test or alarm signal (be sure the sensor's battery is connected or that its battery protection strip is removed). ✴ A single “Bing” tone will sound and the sensor status

ACTIVATE SENSOR

indicator for that sensor will stay lit. A “Buzz” will sound if that sensor location is already in use. 5. Repeat Steps 3 & 4 for each additional sensor, or exit Setup Mode by pressing the OFF button for three seconds.

1 BING AND SENSOR INDICATOR LIGHTS

REPEAT OR EXIT

Page 18 of the Linear DUAL 824 user manual — PROGRAMMING DIFFERENT SENSOR TYPES
Page 18 · click to enlarge
Page 18

PROGRAMMING DIFFERENT SENSOR TYPES

✦ Follow the instructions on the previous page to

select a sensor number to program the sensor into. ✎ NOTE: A sensor can be programmed into more

Linear DUAL 824 — PROGRAMMING DIFFERENT SENSOR TYPES diagram (page 18)
Fig. 30

than one location. Be sure to choose an UNUSED sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function. ✦ To add DXS-10 wireless keypads, press and hold

the keypad's key until programmed into the Control Panel. ✦ For DXS-31 and DXS-32 door/window sensors,

Linear DUAL 824 — PROGRAMMING DIFFERENT SENSOR TYPES diagram (page 18)
Fig. 31

move the magnet away from the side of the sensor. ✎ IMPORTANT NOTE: The DXS-31 & DXS-32 door/

window sensors are pre-set at the factory for delayed burglary response. If the sensor is going to be used on a non-entry portal (window, sliding glass door, etc.) a jumper can be changed in the sensor to select instant response. The jumper should be changed before programming the sensor so the Control Panel will assign the sensor to the proper sensor function. See the “Basic Sensor Installation” section of this manual or the sensor’s instructions for details on changing the jumper. ✦ For DXS-81, DXS-91, DXS-54, DXS-73,

Linear DUAL 824 — PROGRAMMING DIFFERENT SENSOR TYPES diagram (page 18)
Fig. 32

& accessory sensors, simply send a test transmission (refer to the sensor's instructions for details on sending a test transmission).

Page 19 of the Linear DUAL 824 user manual — DXT-42
Page 19 · click to enlarge
Page 19

PROGRAMMING DIFFERENT SENSOR TYPES (CONT.)

Linear DUAL 824 — PROGRAMMING DIFFERENT SENSOR TYPES (CONT.) diagram (page 19)
Fig. 33

✦ For DXT-61, DXT-21, DXS-21, DXT-41, &

DXS-62A single-button remotes, simply press the unit's button. ✎ NOTE: After the Control Panel recognizes the

transmitter, single-button remotes must be re-programmed as “panic buttons” or home automation controllers. Refer to Page 28 in the “Customizing the System” section of this manual. ✦ For DXT-23, DXS-23, & DXT-42 multi-button

remotes: Learn the transmitter by pressing the left button. The remote will arm the Control Panel with the left button and disarm with the right button. Labels are provided with the DXT-42 for identifying the buttons. ✎ NOTE: After the Control Panel “learns” the

SEND SIGNAL WITH LEFT BUTTON

transmitter, multi-button remotes can easily be re-programmed to have the left button arm/disarm the Control Panel and the right button activate/ deactivate the Home Automation output. Refer to the “Advanced Programming” section of this manual.

Linear DUAL 824 — SEND SIGNAL WITH LEFT BUTTON diagram (page 19)
Fig. 34

For All Models:

✴ A single “Bing” tone will sound and the sensor status

DXT-42

indicator will stay lit when the sensor is programmed into the Control Panel. ✴ A “Buzz” tone will sound if there is already another

sensor programmed to that sensor number. ✦ Exit Setup Mode by pressing the key then press OFF for three seconds. Reminder: The system will automatically exit the Setup Mode and return to Off Mode after three minutes of keypad inactivity. ✎ NOTE: To remove sensors from the Control Panel's

LEFT = ARM/DISARM RIGHT = DISARM BOTH = EMERGENCY

memory, see Page 26 in the “Customizing the System” section of this manual.

Page 20 of the Linear DUAL 824 user manual — WALL MOUNT USE
Page 20 · click to enlarge
Page 20

8. BASIC SENSOR INSTALLATION

Linear DUAL 824 — 8. BASIC SENSOR INSTALLATION diagram (page 20)
Fig. 35

✦ Each accessory sensor is packaged with its

FROM TOP OF CASE TWIST SCREWDRIVER BETWEEN CASE HALVES UNTIL IT POPS OPEN

own set of installation instructions specifi c to the model of sensor. ✦ Refer to the sensor's instructions for details

on installing, operating, and testing of the sensor. ✦ Following are basic instructions for installing

two popular DUAL 824 accessories: The Model DXS-10 Wireless Remote Keypad and the Model DXS-31 & DXS-32 Door/Window Transmitters.

DXS-10 WIRELESS KEYPAD

✦ The DXS-10 is used to remotely operate the

system. ✦ The keypad can be simply set on a table or

mounted to a fl at surface.

TABLE-TOP USE

✦ Four anti-mar pads are provided as a scratch

deterrent for the keypad. ✎ NOTE: Do not use the adhesive pads if the keypad

is going to be wall mounted. 1. Peel off the adhesive tape backing on the pads and stick them to the back of the keypad. ✦ The wireless keypad can be used as a portable

USE THE FOUR SCRATCH DETERRENT PADS PROVIDED FOR TABLE-TOP USE

keypad. Because of the hourly supervisory transmissions, if the unit is taken out of range from the Control Panel for more than eight hours, the hardwired keypad will indicate “radio trouble” for the wireless keypad. The keypad's sensor number can be programmed for “non-supervised” if required. See the “Advanced Programming” section of this manual.

Linear DUAL 824 — TABLE-TOP USE diagram (page 20)
Fig. 36

WALL MOUNT USE

✦ The wireless keypad can be wall mounted. 1. Open the keypad by inserting a small screwdriver in one of the top slots in the keypad case. Gently twist the screwdriver until the case pops open. 2. Attach the rear case to the wall using the two screws provided. ✎ NOTE: For best signal transmission, the keypad

should be mounted at least three feet above ground level. 3. Hook the top edge of the keypad case together and snap the keypad onto the rear case. ✎ WARNING: The wireless keypad is designed for

ATTACH REAR CASE TO WALL WITH THE TWO SCREWS PROVIDED

indoor use only.

MOUNT AT A CONVENIENT LOCATION NEAR PRIMARY ENTRY/EXIT DOOR

Page 21 of the Linear DUAL 824 user manual — TEST SENSORS
Page 21 · click to enlarge
Page 21

EXAMPLE INSTALLATIONS (WITH DXS-31 SHOWN)

DXS-31 & DXS-32 DOOR/WINDOW SENSORS

✦ The DXS-31 and DXS-32 sensors can be used

Linear DUAL 824 — EXAMPLE INSTALLATIONS (WITH DXS-31 SHOWN) diagram (page 21)
Fig. 37

to monitor doors, windows, cabinets, crawl space doors, gates, freezer doors, and many other moving objects that could be used for intrusion or need to be monitored. ✦ A built-in magnetic switch triggers the sensor

when its magnet (mounted on the moving part or the door or window) moves away from the sensor. ✦ The DXS-31 sensor can be wired to external

normally closed switches for remote triggering. ✦ The DXS-31 sensor can connect directly to a

glass break detector.

SET SENSOR JUMPER

INSTANT/DELAY OPTION JUMPER

ANTENNA

✦ A jumper inside the door/window sensor selects

MAGNET ALIGNMENT MARK

INPUT SELECT JUMPER

TWO TYPE 2032 BATTERIES

instant or delayed response. 1A. If the sensor is going to be used on the primary entry/exit door make sure that the jumper is in the DELAY position. 1B. If the sensor is going to be used on a window or a door that is not going to be used to enter and exit the premises, set the jumper to the INSTANT position.

BATTERY CLAMP SCREW

TRANSMIT INDICATOR

BATTERY CLAMP

TEST SWITCH

EXTERNAL INPUT TERMINALS

CHOOSE MOUNTING METHOD

INSTANT/DELAY OPTION JUMPER

2A. Apply double-stick tape (supplied) to back of sensors and magnets. 2B. Screws are also provided to mount sensors and magnets. Screws are preferred over the double- stick tape in permanent installations. ✎ UL NOTE: Double-stick tape is not allowed in UL

SELECTS INSTANT

SELECTS DELAY

installations.

ATTACH SENSORS AND MAGNETS

✦ Allow a maximum of 1/2" between magnet and

ATTACH MOUNTING PLATES USING THE SCREWS OR DOUBLE-STICK TAPE PROVIDED

sensor when door/window is closed. ✦ The magnet height is adjustable and an optional

magnet spacer is provided for uneven surfaces. 3A. On doors, mount sensor to door frame and magnet to door. 3B. On windows, mount sensor to window frame and magnet to window. ✎ NOTE: Magnet must line up with mark on sensor

case both horizontally & vertically. 4. Snap sensor onto mounting plate.

TEST SENSORS

✴ In Chime Mode, the hardwired keypad(s) should “ding-

dong” when the sensor sends a signal. 5. Open door or window. ✴ Verify that light on the sensor (if there is one) glows

Linear DUAL 824 — TEST SENSORS diagram (page 21)
Fig. 38

momentarily when door/window is opened. ✴ Status indicator on the hardwired keypad(s) should

remain lit for each door/window sensor that is left open.

Page 22 of the Linear DUAL 824 user manual — USE AN INK PEN TO CUSTOMIZE BLANK LABELS
Page 22 · click to enlarge
Page 22

9. CUSTOMIZING THE KEYPAD

✦ The system can be customized for the specifi c

Linear DUAL 824 — 9. CUSTOMIZING THE KEYPAD diagram (page 22)
Fig. 39

installation. ✦ A label sheet with sensor location names is

provided with DUAL 824KP keypads. ✦ Labeling the sensors allows quick and easy

identifi cation of where a door or window is open, where any alarms have occurred, where a sensor with a low battery is, or where a sensor with trouble is.

LABELING THE SENSOR LOCATIONS

1. Open the keypad's plastic beauty cover to reveal the sensor identifi cation label area. 2. Open one protected door/window to light its sensor status light on the keypad(s). 3. Choose a label that describes the sensor location, or write the location on a blank label, and stick it in the area next to the sensor number. 4. Close the protected opening that you just labeled. 5. Repeat for each protected opening. 6. Stick the WIRELESS KEYPAD label in the sensor number location for the wireless keypad (if used). 7. Close the beauty cover when fi nished.

Linear DUAL 824 — LABELING THE SENSOR LOCATIONS diagram (page 22)
Fig. 40

OPEN DOOR OR WINDOW TO LIGHT SENSOR STATUS INDICATOR ON KEYPAD(S)

USE SENSOR LABELS SUPPLIED TO IDENTIFY EACH SENSOR LOCATION

USE AN INK PEN TO CUSTOMIZE BLANK LABELS

Linear DUAL 824 — USE AN INK PEN TO CUSTOMIZE BLANK LABELS diagram (page 22)
Fig. 41

APPLY THE PRE-PRINTED SENSOR LOCATION LABELS TO SUIT THE INSTALLATION

BLANK LABELS THAT CAN BE FILLED IN WITH AN INK PEN ARE ALSO PROVIDED FOR CUSTOM SENSOR IDENTIFICATION

Page 23 of the Linear DUAL 824 user manual — START IN OFF
Page 23 · click to enlarge
Page 23

10. SYSTEM OPERATING MODES

OFF MODE

✦ Use this mode to disarm the burglary portion of

OFF MODE

the system. ✦ The 24-hour functions are still active in Off Mode

START HERE

and can be triggered with wireless or hardwired sensors, or by pressing the FIRE or EMERGENCY on the keypad(s). 1. Switch to Off Mode by entering the user code, and pressing OFF. ✎ NOTE: The keypad's key resets the keypad's keyboard and can be used before entering any code to assure that any digits recently pressed will not be added to the correct code. Pressing fi rst is optional because the keypad will reset itself after 10 seconds of keyboard inactivity. ✴ When the system is disarmed to Off Mode, the keypad(s)

(OPTIONAL)

YOUR USER CODE

1 GONG

will sound one “Gong”. ✦ Switching to Off Mode stops any alarms in

DONE

progress. ✴ If an alarm has occurred, multiple Beeps will sound after

disarming and the sensor indicator for the sensor(s) that caused the alarm will fl ash. ✎ NOTE: In Off Mode, protected doors and windows

cannot trigger the burglary alarm.

CHIME MODE

✦ Chime Mode is for monitoring entries and exits

CHIME MODE

without causing alarms. ✦ Use Chime Mode as an “automatic door chime”

START HERE

when at home. ✴ Opening any protected door or window causes the

(OPTIONAL)

keypad(s) to sound a “ding-dong”. 1A. Select the Chime Mode by entering a user code, then press CHIME. 1B. The user can enter Chime Mode from Off Mode by pressing CHIME for two seconds. ✴ When the system is switched to the Chime Mode, the

YOUR USER CODE

keypad(s) will sound a “Gong” and one “Beep”. ✦ Switching to Chime Mode disarms the system

and stops any alarms in progress. ✴ If an alarm has occurred, multiple Beeps will sound after

1 GONG & 1 BEEP

disarming and the sensor indicator for the sensor(s) that caused the alarm will fl ash. ✎ NOTE: In Chime Mode, protected doors and

DONE

windows cannot trigger the burglary alarm.

OR QUICK ARM TO CHIME MODE

START IN OFF

HOLD DOWN

1 GONG & 1 BEEP DONE

Page 24 of the Linear DUAL 824 user manual — HOLD DOWN
Page 24 · click to enlarge
Page 24

HOME MODE

MANUAL BYPASSING OF SENSORS

✦ Use this mode when sleeping or when anyone is

✦ Manual bypassing of sensors in the Home Mode

staying inside. ✦ Home Mode causes an instant alarm when any

allows arming of the system at night with open windows, while still having perimeter protection with other closed doors and windows. ✦ If the READY indicator is lit, all sensors are closed. 1. If the READY indicator is not lit, the system will resist arming because of open door or window sensors. ✴ Four high-low Beeps to warn the user that something is

perimeter sensor is triggered. ✦ Home Mode causes a delayed alarm when any

exit/entry sensor is triggered (except in Home Instant Mode when they are instant). ✦ Each burglary sensor can trigger the siren once

per arming period. ✦ Alarm siren stops automatically after fi ve minutes

open and the system will remain in the previous mode. ✴ Lit sensor status indicators show which sensors are

and the system will remain armed. ✦ Home Mode ignores all interior sensors (motion

open. 2. To manually bypass the open sensors, arm the system again within fi ve seconds. ✴ A “Gong” and two “Beeps” will sound, the HOME

detectors, etc.). 1A. Arm to Home Mode by entering a user code, and pressing HOME. 1B. The user can “Quick Arm” to Home Mode from Off or Chime Mode by pressing HOME for two seconds. (Quick arming can be disabled; see the “Advanced Programming” section of this manual.) ✴ When the system is armed to the Home Mode, the

indicator will light, and the open sensors will be bypassed. ✎ WARNING: Bypassed sensors cannot cause an

alarm. Closing the sensor removes the bypass.

keypad(s) will sound a “Gong” and two “Beeps”. 2. Enter a user code and press OFF or CHIME to disarm from Home Mode and/or stop the alarm siren. ✴ If an alarm has occurred, multiple Beeps will sound after

HOME MODE

SECURE EXIT

disarming and the sensor indicator for the sensor(s) that caused the alarm will fl ash (switch to Off Mode again or re-arm the system to stop the fl ashing alarm memory).

START IN OFF OR CHIME MODE

START IN HOME MODE

(OPTIONAL)

(OPTIONAL)

SECURE EXIT

1. If the system is already in the Home Mode and the user wants to exit the premises while leaving someone inside with the system still in Home Mode , enter a user code and press the HOME key. ✴ The HOME light will blink for 60 seconds. No exit delay

YOUR USER CODE

YOUR USER CODE

Beeps will sound during the Exit Delay. 2A. The user can leave through a door with a delayed perimeter sensor during the 60 second Exit Delay without causing the Control Panel to begin an Entry Delay. 2B. Re-entering during the silent Exit Delay will extend the Exit Delay another 60 seconds (one time only). ✎ NOTE: The Exit Delay time can be changed; see the

1 GONG & 2 BEEPS

1 GONG & 2 BEEPS

DONE

DONE

OR QUICK ARM TO HOME MODE

HOME INSTANT

MODE

“Advanced Programming” section of this manual.

HOME INSTANT MODE

START IN OFF OR CHIME MODE

START IN HOME MODE

1. If the system is already in the Home Mode and the user wants to make all exit/entry sensors instant, press HOME for two seconds. ✴ Two “Gongs” and two “Beeps” will sound and the HOME

HOLD DOWN

HOLD DOWN

1 GONG & 2 BEEPS DONE

1 GONG & 2 BEEPS DONE

light and ARMED indicator will blink continuously. 2. Because all exit/entry sensors will now cause an instant alarm when in Home Mode, the system must be disarmed before opening any exit/entry delay door. ✎ NOTE: If quick arming is disabled the Home Instant

Mode is unavailable.

Page 25 of the Linear DUAL 824 user manual — HOLD DOWN
Page 25 · click to enlarge
Page 25

AWAY MODE

MANUAL BYPASSING OF SENSORS

✦ Use this mode when no one will be staying home. ✦ Away Mode causes an instant alarm when any

✦ Manual bypassing of sensors in the Away Mode

allows arming of the system with open doors and windows, while still having perimeter protection with other closed doors and windows. ✦ If the READY indicator is lit, all sensors are closed. 1. If the READY indicator is not lit, the system will resist arming because of open door or window sensors. ✴ Four high-low Beeps to warn the user that something is

perimeter sensor is triggered. ✦ Away Mode causes a delayed alarm when any

exit/entry sensor is triggered. ✦ Away Mode causes an instant alarm when any

interior sensors (motion detectors, etc.) are triggered. The interior sensors will be delayed if a perimeter delayed sensor is triggered fi rst. ✦ Each burglary sensor can trigger the siren once

open and the system will remain in the previous mode. ✴ Lit sensor status indicators show which sensors are

per arming period. ✦ Alarm siren stops automatically after fi ve minutes

open. 2. To manually bypass the open sensors, arm the system again within fi ve seconds. ✴ A “Gong” and three “Beeps” will sound, the AWAY

and the system will remain armed. 1A. Arm to Away Mode by entering a user code, and pressing AWAY. 1B. The user can “Quick Arm” to Away Mode from Home, Chime or Off Mode by pressing AWAY for two seconds. (Quick arming can be disabled; see the “Advanced Programming” section of this manual.)

indicator will light, and the open sensors will be bypassed. ✎ WARNING: Bypassed sensors cannot cause an

alarm. Closing the sensor removes the bypass.

EXIT DELAY (For Leaving the Premises)

✴ When the system is armed to the Away Mode, the

keypad(s) will sound a “Gong” and three “Beeps”. ✴ During the 60 second Exit Delay, the keypad(s) will

sound “Beeps” (double Beeps last 10 seconds) and the AWAY and ARMED indicators will blink. 2A. The Exit Delay gives the user 60 seconds to leave the premises through an exit/entry door without triggering an alarm. 2B. Re-entering during the Exit Delay will extend the Exit Delay another 60 seconds (one time only). ✴ When the Exit Delay is over, the keypad(s) will sound one

AWAY MODE

START IN OFF, CHIME OR HOME MODE

(OPTIONAL)

“Gong” to warn the user that the system is fully armed and the ARMED indicator will light steady. ✎ NOTE: The Exit Delay time can be changed; see the

YOUR USER CODE

“Advanced Programming” section of this manual.

ENTRY DELAY (For Entering the Premises) 3A. The Entry Delay gives the user 30 seconds to enter the premises through an exit/entry door without triggering an alarm. 3B. If a exit/entry sensor is triggered, starting the Entry Delay, the interior sensors will also become delayed (this allows motion in the premises during the Entry Delay). ✴ During the 30 second Entry Delay, the keypad(s) will

1 GONG & 3 BEEPS

DONE

sound “Beeps”. 4. When the Entry Delay is over, the system will go into full alarm and sound the siren if it is not disarmed to the Off or Chime Mode. ✴ If an alarm has occurred while the user was gone,

OR QUICK ARM TO AWAY MODE

START IN OFF, CHIME OR HOME MODE

multiple Beeps will sound after disarming and the sensor light for the sensor(s) that caused the alarm will fl ash (switch to Off Mode again or re-arm the Control Panel to stop the fl ashing alarm memory). ✎ NOTE: The Entry Delay time can be changed; see the

HOLD DOWN

1 GONG & 3 BEEPS DONE

“Advanced Programming” section of this manual.

Page 26 of the Linear DUAL 824 user manual — SENSOR FUNCTION TABLE
Page 26 · click to enlarge
Page 26
✎ NOTEIf the system is left unattended in Test

TEST MODE

Mode, it will automatically switch back to Off Mode after three minutes. ✦ When directly connecting (without a telephone

✦ Even though this is a self-monitoring supervised

system, the National Burglar and Fire Alarm Association recommends that all security systems be tested manually on a regular basis. 1. The system must be in Off Mode before switching to Test Mode. 2. Switch the system into Test Mode by entering a user code and pressing TEST. ✴ When the system is switched to the Test Mode, the

line) to the DUAL 824 with the RA-2400 remote access software (Version 1.3 or later), press the EMERGENCY key while in Test Mode to cause the control panel to connect to the modem.

keypad(s) will sound a “Gong” and four “Beeps”. 3. Holding down the TEST button in Test Mode will light all of the keypad’s indicators. ✴ The sensor status indicators will fl ash for each sensor

TEST MODE

Linear DUAL 824 — TEST MODE diagram (page 26)
Fig. 42

programmed into the Control Panel. 4. Go to each sensor and press its test button or open and close the protected opening. 5. To test the wireless keypad, press the wireless keypad’s key. ✴ The keypad(s) will make a “Bing” sound as each sensor

is tested, followed by 1-3 beeps indicating signal strength with 3 beeps being the strongest signal. ✴ As each sensor is tested, the sensor status indicator for

the sensor will stop fl ashing and return to showing the current status of the sensor. 6. Continue testing until there are no fl ashing sensor status indicators.

Linear DUAL 824 — TEST MODE diagram (page 26)
Fig. 43

SENSOR FUNCTION OFF MODE CHIME MODE HOME MODE AWAY MODE

2-BUTTON ARM/DISARM (LEFT) 2-BUTTON AUTOMATION (RIGHT) EMERGENCY (BOTH BUTTONS)

LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE † IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡ LEFT BUTTON SWITCHES SYSTEM TO OFF MODE ‡

2-BUTTON ARM (LEFT) 2-BUTTON DISARM (RIGHT) EMERGENCY (BOTH BUTTONS)

LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE † IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡ RIGHT BUTTON SWITCHES SYSTEM TO OFF MODE ‡

† CAN BE HOME MODE USING PROGRAMMING STEP 50 ‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51

SENSOR FUNCTION TABLE

Page 27 of the Linear DUAL 824 user manual — RADIO INDICATOR
Page 27 · click to enlarge
Page 27

11. SYSTEM TROUBLE INDICATIONS

✦ The DUAL 824P Control Panel is a self-

monitoring supervised wireless system. If the Control Panel detects a problem with any of the supervised system sensors or with its power, it will display the appropriate trouble indication and, if monitored, report the trouble to the Central Station through the communicator (depending on communicator programming).

CONTROL PANEL POWER

TROUBLE INDICATOR

✦ The Control Panel constantly charges and

Linear DUAL 824 — CONTROL PANEL POWER diagram (page 27)
Fig. 44

monitors the optional backup battery (if installed). ✴ The POWER indicator normally glows when AC power is

on. ✦ If the Control Panel’s power condition is

POWER INDICATOR NORMALLY ON WITH AC POWER AND CHARGED BACKUP BATTERY

abnormal, the keypad's TROUBLE indicator will light. The POWER light will indicate the type of trouble. ✴ With a charged backup battery installed, if the Control

BLINKS WITH LOW, RECHARGING OR MISSING BACKUP BATTERY

BLINKS WHEN AC POWER IS ABSENT AND CONTROL PANEL IS RUNNING ON BACKUP BATTERY

Panel looses AC power, the POWER indicator will blink as the Control Panel runs on the backup battery. ✴ If the backup battery is low, recharging, or not installed,

the POWER indicator blinks when AC power is present. ✴ If the AC power is off and no backup battery is installed,

or the battery fuse is blown, the POWER indicator will be off (in this case, the system has no power, all indicators are dark, and the system is disabled). ✦ Normal battery life for the type of backup battery

Linear DUAL 824 — BLINKS WITH LOW, RECHARGING OR MISSING BACKUP BATTERY diagram (page 27)
Fig. 45

TROUBLE INDICATOR LIGHTS IF THERE IS SENSOR BATTERY TROUBLE

used in the Control Panel is 3-4 years. If the battery does not take a charge in 72 hours, it should be replaced.

WIRELESS SENSOR LOW BATTERIES

✴ If the TROUBLE indicator lights, and the BATTERIES

BATTERIES INDICATOR

indicator is blinking, one or more wireless sensors have a low battery. 1. Press for one second to view sensor status. The sensor status indicator for any sensor with a low battery will light along with the BATTERIES indicator. 2. Replace the wireless sensor's battery as described in its instructions. 3. Switch to Test Mode after replacing the wireless sensor battery and completely test the system (see Test Mode). Switching to Test Mode clears the trouble indication.

BLINKS WHEN ONE OR MORE WIRELESS SENSORS HAVE A LOW BATTERY

LIGHTS WITH SENSOR # INDICATION DURING LOW BATTERY STATUS CHECK (PRESS FOR 1 SECOND)

TROUBLE INDICATOR

Linear DUAL 824 — TROUBLE INDICATOR diagram (page 27)
Fig. 46

SENSOR RADIO TROUBLE

✴ If the TROUBLE indicator lights, and the RADIO indicator

is blinking, status reports from one or more wireless sensors have not received in eight hours. 1. Press for one second to view sensor status. The sensor status indicator for any sensor with trouble will light along with the RADIO indicator. 2. Switch to Test Mode after servicing the sensor and completely test the system (see Test Mode). Switching to Test Mode clears the trouble indication.

RADIO INDICATOR

BLINKS WHEN STATUS SIGNALS FROM ONE OR MORE WIRELESS SENSORS HAVE NOT BEEN RECEIVED IN EIGHT HOURS

LIGHTS WITH SENSOR # INDICATION DURING RADIO STATUS CHECK (PRESS FOR 1 SECOND)

Page 28 of the Linear DUAL 824 user manual — 1 BING & SENSOR INDICATOR DARK
Page 28 · click to enlarge
Page 28

12. CUSTOMIZING THE SYSTEM

✦ Adding additional sensors will increase the

START IN TEST

protection provided by the system. ✦ All ground-level perimeter openings and

accessible upper-story openings need protection. ✦ Motion detectors can protect interior areas and

MASTER USER CODE

areas where valuables are kept.

ADDING SENSORS TO THE SYSTEM

1. Always start with the system in Test Mode (enter a user code and press TEST ). 2. Enter the master user code then press TEST . ✴ A “Gong” and fi ve “Beeps” will sound. ✴ The sensor status indicators will light for each sensor

1 GONG & 5 BEEPS (SETUP MODE)

NEW SENSOR NUMBER

programmed into the Control Panel. 3. Enter an unused sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✎ NOTE: A sensor can be programmed into more

SENSOR INDICATOR FLASHES

than one location. Be sure to choose an UNUSED sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function. ✴ The sensor status indicator light will fl ash for the sensor

ACTIVATE SENSOR

1 BING AND SENSOR INDICATOR LIGHTS

number selected. 4. Activate the sensor. (To add a wireless keypad, press the keypad's key.) ✴ A “Bing” tone will sound when the sensor is programmed

REPEAT OR EXIT

into the Control Panel and the sensor status indicator will stay lit. ✴ A “Buzz” tone will sound if there is already another

sensor programmed to that sensor number. 5. Enter another sensor number, or exit Setup Mode by pressing the key then press OFF for three seconds.

START IN TEST

REMOVING SENSORS FROM THE SYSTEM

✦ If a previously programmed sensor isn't going

to be used with the system anymore, or it's a duplicate that has been entered into more than one sensor location, it should be removed from the Control Panel's memory. 1. Start with the system in Test Mode. 2. Enter the master user code then press TEST. ✴ A “Gong” and fi ve “Beeps” will sound. ✴ The sensor status indicators will light for each sensor

MASTER USER CODE

1 GONG & 5 BEEPS (SETUP MODE)

programmed into the Control Panel. 3. Enter the sensor number (from 01-24) that you want to remove (you must enter two digits, example: 5 = 05). ✴ The sensor status indicator light will fl ash for the sensor

NUMBER OF SENSOR TO REMOVE

SENSOR INDICATOR FLASHES

number selected. 4. Press TEST. ✴ A “Bing” tone will sound when the sensor has been

REMOVES SENSOR

removed and the sensor status indicator will turn off. 5. Enter another sensor number, or exit Setup Mode by pressing the key then press OFF for three seconds.

1 BING & SENSOR INDICATOR DARK

REPEAT OR EXIT

Page 29 of the Linear DUAL 824 user manual — 1 BING AND SENSOR INDICATOR LIT
Page 29 · click to enlarge
Page 29

MAKING A SENSOR A 24-HOUR DOOR CHIME

START IN TEST

✦ Sensors can be programmed to cause the

keypad(s) to chime any time they're activated. ✦ Chime-only sensors will not be able to trigger the

alarm in any system mode. ✦ The sensor must have already been programmed

MASTER USER CODE

into the Control Panel (see “Adding Sensors to the System” for details). 1. Start with the system in Test Mode. 2. Enter the master user code then press TEST. ✴ A “Gong” and fi ve “Beeps” will sound. ✴ The sensor status indicators will light for each sensor

1 GONG & 5 BEEPS (SETUP MODE)

NUMBER OF SENSOR TO CHANGE

programmed into the Control Panel. 3. Enter the sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✴ The sensor status indicator light will fl ash for the sensor

SENSOR INDICATOR FLASHES

number selected. 4. Press HOME, 8, then AWAY. ✴ A “Bing” tone will sound and the sensor status indicator

ENTERS SENSOR NUMBER

will light steady. 5. Enter another sensor number, or exit Setup Mode by pressing the key then press OFF for three seconds.

8 TO SELECT CHIME SENSOR FUNCTION

STORES CHANGE

1 BING AND SENSOR INDICATOR LIT

MAKING A SENSOR INTERIOR

✦ Wireless motion detectors are automatically

programmed as interior sensors. Any other sensor can also be programmed as an interior sensor. ✦ Interior sensors can only trigger an alarm when

START IN TEST

MASTER USER CODE

the system is in the Away Mode. ✦ “Home Interior” sensors can trigger an alarm

when the Control Panel is in the Home or Away mode. ✦ The sensor must have already been programmed

1 GONG & 5 BEEPS (SETUP MODE)

into the Control Panel (see “Adding Sensors to the System” for details). 1. Start with the system in Test Mode. 2. Enter the master user code then press TEST. ✴ A “Gong” and fi ve “Beeps” will sound. ✴ The sensor status indicators will light for each sensor

NUMBER OF SENSOR TO CHANGE

SENSOR INDICATOR FLASHES

programmed into the Control Panel. 3. Enter the sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✴ The sensor status indicator light will fl ash for the sensor

ENTERS SENSOR NUMBER 7 TO SELECT INTERIOR SENSOR FUNCTION

number selected. 4. Press HOME, 7, then AWAY. ✴ A “Bing” tone will sound and the sensor status indicator

STORES CHANGE

will light steady. 5. Enter another sensor number, or exit Setup Mode by pressing the key then press OFF for three seconds.

1 BING AND SENSOR INDICATOR LIT

Page 30 of the Linear DUAL 824 user manual — SENSOR FUNCTION TABLE
Page 30 · click to enlarge
Page 30

MAKING A SENSOR PERFORM A DIFFERENT FUNCTION

Linear DUAL 824 — MAKING A SENSOR PERFORM A DIFFERENT FUNCTION diagram (page 30)
Fig. 47

✦ Sensors can be reprogrammed to perform

different sensor functions. ✦ The sensor must have already been programmed

into the Control Panel (see “Adding sensors to the System” for details). 1. Start with the system in Test Mode. 2. Enter the master user code then press TEST. ✴ A “Gong” and fi ve “Beeps” will sound. ✴ The sensor status indicators will light for each sensor

programmed into the Control Panel. 3. Enter the sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✴ The sensor status indicator light will fl ash for the sensor

number selected. 4. Choose a sensor function number from the Sensor Function Table. 5. Press HOME, the new sensor function number, then AWAY. ✴ A “Bing” tone will sound and the sensor status indicator

will light steady. 6. Enter another sensor number or exit Setup Mode by pressing the key then press OFF for three seconds.

Linear DUAL 824 — MAKING A SENSOR PERFORM A DIFFERENT FUNCTION diagram (page 30)
Fig. 48

FUNC- TION # SENSOR FUNCTION OFF MODE CHIME MODE HOME MODE AWAY MODE

3 PANIC ARMED 24-HOURS - TRIGGERS SILENT PANIC ALARM

INSTANT BURGLARY ALARM UNLESS ACTIVATED DURING AN ENTRY DELAY, THEN IT IS

9 2-BUTTON ARM/DISARM (LEFT) 2-BUTTON AUTOMATION (RIGHT) EMERGENCY (BOTH BUTTONS)

LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE † IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡ LEFT BUTTON SWITCHES SYSTEM TO OFF MODE ‡

10 2-BUTTON ARM (LEFT) 2-BUTTON DISARM (RIGHT) EMERGENCY (BOTH BUTTONS)

LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE † IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡ RIGHT BUTTON SWITCHES SYSTEM TO OFF MODE ‡

† CAN BE HOME MODE USING PROGRAMMING STEP 50 ‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51

SENSOR FUNCTION TABLE

Page 31 of the Linear DUAL 824 user manual — 87 REMOTE ACCESS PASSWORD 6 DIGITS 987654
Page 31 · click to enlarge
Page 31

13. ADVANCED PROGRAMMING

✦ To perform any of the advanced programming

SETUP MODE

steps, the system must be in the Setup Mode. ✦ Each programming function is performed with

1. Start with the system in Test Mode (Setup Mode cannot be reached from any other mode). 2. From Test Mode, enter the master user code then press TEST . ✎ NOTE: Only the master user code can be used to

similar keystrokes. After the system is in Setup Mode, enter the programming step or sensor number and press HOME, then enter the new value and press AWAY. For reference, follow the fi gures next to the programming steps. ✴ If the new value is accepted, a “bing” will sound. If the

put the system into the Setup Mode. The restricted user codes cannot access Setup Mode, only Code Mode. ✴ A “Gong” and fi ve “Beeps” will sound, signaling that the

new value is not accepted, a “double buzz” will sound.

system is in Setup Mode. 3. After programming changes are complete, press the OFF key for three seconds to exit Setup Mode. ✎ NOTE: If the system is left unattended in Setup

ENTERS PROGRAM STEP OR SENSOR NUMBER TO MODIFY

STORES NEW VALUE

Mode, it will automatically switch back to Off Mode after three minutes.

CONTROL PANEL PROGRAMMING OPTIONS

STEP # PROGRAMMING FUNCTIONS POSSIBLE VALUES FACTORY VALUE INSTALLATION VALUE

25 ENTRY DELAY 20-255 SECONDS 30

26 EXIT DELAY 20-255 SECONDS 60

30 BURGLARY SIREN TIME 1-30 MINUTES 5

31 EMERGENCY SIREN TIME 1-30 MINUTES 5

32 FIRE SIREN TIME 1-30 MINUTES 5

40 AUTOMATION OUTPUT TIME 0-2500 SECONDS (0 = TOGGLE ON/OFF) 0

50 REMOTE ARMING MODE 2 = HOME MODE; 3 = AWAY MODE 3

51 REMOTE DISARMING MODE 0 = OFF MODE; 1 = CHIME MODE 0

61 ENTRY DELAY BEEPS 0 = OFF; 1 = ON 1

62 EXIT DELAY BEEPS 0 = OFF; 1 = ON 1

63 SILENT BURGLARY ALARM 0 = AUDIBLE; 1 = SILENT 0

64 SILENT EMERGENCY ALARM 0 = AUDIBLE; 1 = SILENT 0

65 QUICK ARMING 0 = OFF; 1 = ON 1

66 AUTO RESTORE 0 = OFF; 1 = ON 1

67 AUTO BYPASS 0 = OFF; 1 = ON 0

68 AUTOMATION MODE DURING ALARM 0 = FLASH (ENABLED BY FUNCTION 72) 1 = STEADY (ENABLED BY FUNCTION 72) 0

69 AUTOMATION BING TOME 0 = NO BINGS 1 = BINGS 1

70 REMOTE ARM/DISARM CHIRP 0 = NO CHIRPS 1 = CHIRPS (1 CHIRP = ARMED, 2 CHIRPS = DISARMED) 1

71 AUTOMATION FLASHES AFTER ALARM 0 = STANDARD 1 = FLASHING AFTER ALARM 0

0 = STANDARD 1 = AUTOMATION ACTIVE DURING ALARM (FLASH OR STEADY PROGRAMMED BY FUNCTION 68)

72 AUTOMATION ACTIVE DURING ALARM

73 AUTOMATION ON WHILE ARMED 0 = STANDARD 1 = ON WHILE ARMED 0

74 AUTOMATION ON DURING EXIT/ENTRY 0 = STANDARD 1 = ON DURING EXIT/ENTRY DELAY 0

75 AUTOMATION POLARITY 0 = + WHEN OFF; 1 = + WHEN ON 1

87 REMOTE ACCESS PASSWORD 6 DIGITS 987654

92 DURESS CODE 1-5 DIGITS REMOVED

93 RESTRICTED USER CODE #1 1-5 DIGITS REMOVED

94 RESTRICTED USER CODE #2 1-5 DIGITS REMOVED

95 RESTRICTED USER CODE #3 1-5 DIGITS REMOVED

96 RESTRICTED USER CODE #4 1-5 DIGITS REMOVED

97 RESTRICTED USER CODE #5 1-5 DIGITS REMOVED

98 PAGE ALERT USER CODE 1-5 DIGITS REMOVED

99 MASTER USER CODE 1-5 DIGITS 1234

Control Panel Programming Table

Page 32 of the Linear DUAL 824 user manual — TIME IN MINUTES 1 - 30
Page 32 · click to enlarge
Page 32

CHANGING A SENSORS SUPERVISION

NUMBER OF SENSOR TO CHANGE

✦ When a wireless sensor is programmed, the

Control Panel automatically sets it to supervised or non-supervised. The hardwire loops are always supervised for end-of-line resistor termination. ✦ The Control Panel expects hourly status

SENSOR INDICATOR FLASHES

ENTERS SENSOR NUMBER

transmissions from any wireless sensor programmed as supervised. ✦ Any wireless sensor can be programmed as

16 FOR NON-SUPERVISED 17 FOR SUPERVISED

supervised or non-supervised using this process. ✎ NOTE: Don't program a wireless sensor that

STORES CHANGE

1 BING AND SENSOR INDICATOR LIT

doesn't send status transmissions as supervised.

CHANGING A SENSORS RESTORE REQUIREMENTS

NUMBER OF SENSOR TO CHANGE

✦ When a wireless sensor is programmed, the

Control Panel automatically recognizes it as manual or automatic restoring. The hardwired loops are always manual restoring. ✦ The Control Panel expects restoral signals from any

SENSOR INDICATOR FLASHES

ENTERS SENSOR NUMBER

wireless sensor programmed as manual restore. ✦ Any wireless sensor can be programmed as

18 FOR MANUAL RESTORE 19 FOR AUTO RESTORE

manual or automatic restore using this process. ✎ NOTE: Don't program a wireless sensor that doesn't

STORES CHANGE

send restoral transmissions as manual restore.

1 BING AND SENSOR INDICATOR LIT

ENTRY DELAY TIME

✦ The factory-set Entry Delay time is 30 seconds. STEP #25 The Entry Delay time can be adjusted from 20 to

PROGRAMMING STEP #25

255 seconds using this step. Write the new Entry Delay time in the User's Guide. ✎ NOTE: Don't make the Entry Delay too short. The

TIME IN SECONDS 20 - 255

user may not have enough time to disarm the system before an alarm.

STORES VALUE - 1 BING

EXIT DELAY TIME

✦ The factory-set Exit Delay time is 60 seconds. STEP #26 The Exit Delay time can be adjusted from 20 to

PROGRAMMING STEP #26

255 seconds using this step. Write the new Exit Delay time in the User's Guide.

TIME IN SECONDS 20 - 255

STORES VALUE - 1 BING

BURGLARY SIREN TIME

✦ The factory-set burglary siren time is fi ve minutes

PROGRAMMING STEP #30

(UL installation maximum). STEP #30 The burglary siren time can be adjusted from one

to 30 minutes using this step.

TIME IN MINUTES 1 - 30

STORES VALUE - 1 BING

EMERGENCY SIREN TIME

✦ The factory-set emergency siren time is fi ve

PROGRAMMING STEP #31

minutes (UL installation maximum). STEP #31 The emergency siren time can be adjusted from

one to 30 minutes using this step.

TIME IN MINUTES 1 - 30

STORES VALUE - 1 BING

Page 33 of the Linear DUAL 824 user manual — STORES VALUE - 1 BING
Page 33 · click to enlarge
Page 33

FIRE SIREN TIME

✦ The factory-set fi re siren time is fi ve minutes (UL

PROGRAMMING STEP #32

installation maximum). STEP #32 The fi re siren time can be adjusted from one to

30 minutes using this step.

TIME IN MINUTES 1 - 30

STORES VALUE - 1 BING

AUTOMATION OUTPUT TIME

✦ The factory setting causes the Automation

PROGRAMMING STEP #40

Output to toggle between on and off with each activation. STEP #40 The Automation Output can be programmed to

turn on, then automatically turn off after one to 2500 seconds (42 minutes), or toggle on & off, using this step.

TIME IN SECONDS 1 - 2500 0 = TOGGLE ON & OFF

STORES VALUE - 1 BING

REMOTE CONTROL & HARDWIRE ARMING LEVEL

✦ The factory setting causes the portable remote

PROGRAMMING STEP #50

controls to arm to the Away Mode. STEP #50 The portable remote controls can be changed to

arm to the Home Mode using this step. ✎ NOTE: Changing this setting will affect all the

2 FOR HOME MODE 3 FOR AWAY MODE

portable remote controls used with the system and all hardwired loops programmed as arm/disarm (sensor Function #9) key stations.

STORES VALUE - 1 BING

REMOTE CONTROL & HARDWIRE DISARMING LEVEL

✦ The factory setting causes the portable remote

PROGRAMMING STEP #51

controls to disarm to the Off Mode. STEP #51 The remote controls can be changed to disarm to

the Chime Mode using this step. ✎ NOTE: Changing this setting will affect all the

0 FOR OFF MODE 1 FOR CHIME MODE

portable remote controls used with the system and all hardwired loops programmed as arm/disarm (sensor Function #9) key stations.

STORES VALUE - 1 BING

ENTRY DELAY BEEPS

✦ The factory setting causes the keypad(s) to beep

during Entry Delays. STEP #61 The Entry Delay beeps can be silenced using

PROGRAMMING STEP #61

this step. ✦ With the Entry Delay beeps off, the keypad(s) will

0 FOR ENTRY BEEPS OFF 1 FOR ENTRY BEEPS ON

be silent after a delayed sensor is triggered until the Entry Delay expires, then the alarm siren will sound.

STORES VALUE - 1 BING

EXIT DELAY BEEPS

✦ The factory setting causes the keypad(s) to beep

during Exit Delays. STEP #62 The Exit Delay beeps can be silenced using this

PROGRAMMING STEP #62

step. ✦ With the Exit Delay beeps off, the keypad(s) will

0 FOR EXIT BEEPS OFF 1 FOR EXIT BEEPS ON

be silent after arming to the Away Mode until the Exit Delay expires, then a single “Gong” tone will sound.

STORES VALUE - 1 BING

Page 34 of the Linear DUAL 824 user manual — STORES VALUE - 1 BING
Page 34 · click to enlarge
Page 34

SILENT BURGLARY ALARMS

✦ The factory setting causes audible burglary

PROGRAMMING STEP #63

alarms. STEP #63 The Control Panel can be programmed for silent

burglary alarms using this step.

PROGRAM

0 FOR AUDIBLE BURGLARY 1 FOR SILENT BURGLARY

STORE - 1 BING

SILENT EMERGENCY ALARMS

✦ The factory setting causes audible emergency

PROGRAMMING STEP #64

alarms. STEP #64 The Control Panel can be programmed for silent

emergency alarms using this step.

0 FOR AUDIBLE EMERGENCY 1 FOR SILENT EMERGENCY

STORES VALUE - 1 BING

DISABLING QUICK ARMING

✦ The factory setting allows quick arming of the

Control Panel by pressing down the mode keys for two seconds. STEP #65 The Control Panel can be programmed to not

PROGRAMMING STEP #65

allow quick arming using this step. If quick arming is disabled, a user code must be entered before pressing the mode buttons. ✎ NOTE: For commercial installations with retail

0 FOR QUICK ARMING OFF 1 FOR QUICK ARMING ON

traffi c, it is recommended to disable quick arming to prevent customers from arming the system. ✎ NOTE: If quick arming is disabled the Home Instant

STORES VALUE - 1 BING

Mode is unavailable.

AUTOMATIC RESTORAL OF BYPASSED SENSORS

✦ Bypassed sensors are ignored by the Control

Panel and cannot cause an alarm. ✦ The factory setting causes the Control Panel to

automatically restore (remove the bypass from) sensors that close. After it's restored, the sensor is ready to cause an alarm the next time it is opened. STEP #66 The Control Panel can be programmed to not

PROGRAMMING STEP #66

automatically restore any bypassed sensor when the sensor closes using this step. Bypassed sensors will then remain bypassed until the system is disarmed. ✎ NOTE: This setting affects all sensors.

0 FOR AUTO RESTORAL OFF 1 FOR AUTO RESTORAL ON

STORES VALUE - 1 BING

AUTOMATIC BYPASSING OF OPEN SENSORS

✦ The factory setting requires the user to manually

bypass any open sensors when the system is armed. ✴ If arming is attempted with open sensors, the keypad(s)

PROGRAMMING STEP #67

will sound fi ve two-tone Beeps and will not arm. ✦ Arming to the same mode again within fi ve

seconds will bypass any open sensors and arm the Control Panel. STEP #67 The Control Panel can be programmed to

0 FOR AUTO BYPASS OFF 1 FOR AUTO BYPASS ON

automatically bypass any open sensors when the system is armed using this step. ✎ NOTE: This setting affects all sensors.

STORES VALUE - 1 BING

Page 35 of the Linear DUAL 824 user manual — STORES VALUE - 1 BING
Page 35 · click to enlarge
Page 35

AUTOMATION OUTPUT MODE DURING ALARM

✦ The factory setting causes the Automation

PROGRAMMING STEP #68

Output to fl ash if it is programmed to activate during or after an alarm. ✎ NOTE: For the Automation Output to activate

during or after an alarm, that function must be enabled with Programming Step 71 or 72. STEP #68 The output can be programmed to be a steady

0 FOR FLASHING OUTPUT 1 FOR STEADY OUTPUT

STORES VALUE - 1 BING

output using this step.

AUTOMATION ACTIVATION TONE

✦ The factory setting causes the keypad(s) to

PROGRAMMING STEP #69

sound a “Bing” when the Automation Output is activated by pressing the key, or when it's triggered with a two-button remote control. STEP #69 This sound can be silenced using this step.

0 FOR BING TONE OFF 1 FOR BING TONE ON

STORES VALUE - 1 BING

REMOTE CONTROL & HARDWIRE ARM/DISARM CHIRP

✦ When arming with the portable remote control

or with a hardwired loop programmed as arm/ disarm (sensor Function #9), the factory setting causes the keypad(s) to “chirp” once when armed, twice when disarmed, and three times when arming with sensors bypassed. STEP #70 These chirps can be silenced using this step.

PROGRAMMING STEP #70

0 FOR CHIRPS OFF 1 FOR CHIRPS ON

✎ NOTEIf these chirps are silenced, it is

recommended to program the Automation Output to be active when the system is armed, so a light can be triggered displaying the arming status of the system.

STORES VALUE - 1 BING

AUTOMATION OUTPUT ON DURING AND AFTER ALARM

✦ The factory setting causes the Control Panel's

Automation Output to activate when pressing the

key, or when it's triggered with a two-button remote control. STEP #71 The Control Panel can be programmed to

PROGRAMMING STEP #71

activate the Automation Output during and after any alarms as well as when normally triggered using this step. ✎ NOTE: The output will continue until the fl ashing

0 FOR STANDARD TRIGGER 1 FOR OUTPUT DURING & AFTER ALARM STORES VALUE - 1 BING

sensor status lights are cleared.

AUTOMATION OUTPUT ON DURING ALARM

✦ The factory setting causes the Control Panel's

Automation Output to activate when pressing the

PROGRAMMING STEP #72

key, or when it's triggered with a two-button remote control. STEP #72 The Control Panel can be programmed to

activate the Automation Output during alarms as well as when normally triggered using this step. ✎ NOTE: The Automation Output can be programmed

0 FOR STANDARD TRIGGER 1 FOR OUTPUT DURING ALARM

STORES VALUE - 1 BING

to fl ash or be steady during alarm, see Programming Step 68.

Page 36 of the Linear DUAL 824 user manual — STORES CODE - 1 BING
Page 36 · click to enlarge
Page 36

AUTOMATION OUTPUT WHILE ARMED

✦ The factory setting causes the Control Panel's

PROGRAMMING STEP #73

Automation Output to activate when pressing the

key, or when it's triggered with a two-button remote control. STEP #73 The Control Panel can be programmed to

0 FOR STANDARD TRIGGER 1 FOR OUTPUT WHEN ARMED

activate the Automation Output when the system is armed as well as when normally triggered using this step.

STORES VALUE - 1 BING

AUTOMATION OUTPUT DURING EXIT/ENTRY DELAYS

✦ The factory setting causes the Control Panel's

Automation Output to activate when pressing the

PROGRAMMING STEP #74

key, or when it's triggered with a two-button remote control. STEP #74 The Control Panel can be programmed to

0 FOR STANDARD TRIGGER 1 FOR OUTPUT DURING EXIT/ENTRY DELAYS STORES VALUE - 1 BING

activate the Automation Output during the exit and Entry Delays as well as when normally triggered using this step.

AUTOMATION OUTPUT POLARITY

✦ The factory setting causes the Control Panel's

PROGRAMMING STEP #75

Automation Output to provide a current limited voltage source when activated. STEP #75 The Control Panel can be programmed so the

Automation Output provides a current limited voltage source when deactivated using this step.

0 FOR VOLTAGE WHEN OFF 1 FOR VOLTAGE WHEN ON

STORES VALUE - 1 BING

REMOTE ACCESS PASSWORD

✦ This password is used to gain access to the Control

PROGRAMMING STEP #87

Panel when using the RA-2400 remote access software. The password must be 6-digits long. STEP #87 Use this step to enter a new remote access

password then log the password in the box below.

6-DIGIT REMOTE ACCESS PASSWORD

STORES PASSWORD - 1 BING REMOTE ACCESS PASSWORD:

DURESS CODE

✦ The duress code will disarm the system, without

PROGRAMMING STEP #92

any special indications or sounds, but will send the programmed duress code to the Central Station. The code should be two or more digits different than any user code STEP #92 Use this step to enter the duress code then log

1-5 DIGIT DURESS CODE (3-5 DIGITS RECOMMENDED)

the code in the box below.

STORES CODE - 1 BING DURESS CODE:

MASTER USER CODE

✦ The master user code is 1234 when power is fi rst

applied to the Control Panel. ✦ The master user code can be changed to any

PROGRAMMING STEP #99

1-5 digit code. Only the master user can access Setup Mode, restricted users cannot. ✎ NOTE: For maximum security, a 3-5 digit code is

1-5 DIGIT MASTER CODE (3-5 DIGITS RECOMMENDED)

recommended. STEP #99 Use this step to enter the new master user code

then log the code in the box below.

STORES CODE - 1 BING

MASTER USER CODE:

Page 37 of the Linear DUAL 824 user manual — REMOVES CODE - 1 BING
Page 37 · click to enlarge
Page 37

ADDING ADDITIONAL USER CODES

✦ The Control Panel can be programmed with fi ve

PROGRAMMING STEP #93-98

restricted user codes and one page alert user code. ✦ The restricted user codes operate the system as

usual, but cannot access Setup Mode. ✦ The restricted user codes can access a special

1-5 DIGIT ADDITIONAL USER CODE (3-5 DIGITS RECOMMENDED)

Code Mode that can be used to change or remove any of the fi ve restricted user codes, the page alert user code, or the duress code. ✦ The page alert user code dials the supervisory

STORES CODE - 1 BING

number (programmed for a pager) when it is used to arm or disarm the system. ✦ A restricted user code is appropriate to give any

STEP CODE FUNCTION CODE ENTERED

STEP #93 RESTRICTED USER CODE #1

user that should be restricted from programming the Control Panel. ✎ NOTE: For maximum security, a 3-5 digit code is

STEP #94 RESTRICTED USER CODE #2

STEP #95 RESTRICTED USER CODE #3

STEP #96 RESTRICTED USER CODE #4

recommended. ✎ WARNINGNEVER PROGRAM ANY RESTRICTED

STEP #97 RESTRICTED USER CODE #5

STEP #98 PAGE ALERT USER CODE

USER CODE THE SAME AS THE MASTER USER CODE! STEPS #93-98 Create any additional user codes using these

steps then log the codes in the boxes to the right.

REMOVING ADDITIONAL USER CODES

STEPS #93-98 Any additional user code can be removed

ENTER FOR STEP #

from the Control Panel by entering the appropriate step number and pressing TEST. ✦ Because access to programming would be

93 = RESTRICTED CODE 1 94 = RESTRICTED CODE 2 95 = RESTRICTED CODE 3 96 = RESTRICTED CODE 4 97 = RESTRICTED CODE 5 98 = PAGE ALERT USER CODE

impossible without a master user code, it cannot be removed using these steps. The master user code can be changed using programming STEP #99. ✎ NOTE: The master user code can be set to the

PROGRAMMING STEP #93-98

factory default using the Control Panel master reset programming step, although all other system programming will be reset to factory values and all sensors programmed will be erased.

REMOVES CODE - 1 BING

CONTROL PANEL MASTER RESET

✦ Master resetting the Control Panel will set all of the

Linear DUAL 824 — REMOVES CODE - 1 BING diagram (page 37)
Fig. 49

programming options back to the factory values. The master user code will be reset to 1234. ✎ CAUTION: Master resetting the Control Panel will erase

the user codes and remove all programmed sensors. All Control Panel and communicator programming values will be reset to the factory defaults. 1. Start with the system in Test Mode (Setup Mode cannot be reached from any other mode). 2. From Test Mode, enter the master user code then press TEST. ✴ A “Gong” and fi ve “Beeps” will sound, signaling that the

USE THESE EXACT KEYSTROKES TO PERFORM A MASTER RESET ENTERS STEP NUMBER

system is in Setup Mode. 3. Enter programming STEP #999 then press TEST. 4. Enter 999 again then press TEST again. ✴ A “Bing” will sound to indicate the beginning of the reset

process. This process will take up to 10 seconds while the memory is being reset. ✦ The system will revert to the fi rst time power-

PRESS TEST, 1 BING SOUNDS, WAIT ABOUT 10 SECONDS

up condition and the new master user code will be 1234. Go to the “Basic Control Panel Programming” section of this manual to begin re- programming the system.

Page 38 of the Linear DUAL 824 user manual — GENERAL COMMUNICATOR OPTIONS
Page 38 · click to enlarge
Page 38

14. COMMUNICATOR PROGRAMMING

✦ To perform any of the advanced programming

steps, the system must be in the Setup Mode. ✦ Each programming function is performed with

ENTERS PROGRAM STEP NUMBER TO MODIFY

similar keystrokes. After the system is in Setup Mode, enter the programming step number and press HOME, then enter the new value and press AWAY. For reference, follow the fi gures next to the programming steps. ✴ If the new value is accepted, a “Bing” will sound. If the

STORES NEW VALUE

new value is not accepted, a “Double Buzz” will sound.

SETUP MODE

1. Start with the system in Test Mode (Setup Mode cannot be reached from any other mode). 2. From Test Mode, enter the master user code then press TEST . ✎ NOTE: Only the master user code can be used to

START IN TEST

put the system into the Setup Mode. The restricted user codes cannot access Setup Mode, only Code Mode. ✴ A “Gong” and fi ve “Beeps” will sound, signaling that the

MASTER USER CODE

system is in Setup Mode. 3. After programming changes are complete, press the OFF key for three seconds to exit Setup Mode. ✎ NOTE: If the system is left unattended in Setup

1 GONG & 5 BEEPS (SETUP MODE)

Mode, it will automatically switch back to Off Mode after three minutes.

GENERAL COMMUNICATOR OPTIONS

STEP # PROGRAMMING

POSSIBLE

FACTORY

INSTALLATION

FUNCTION

VALUES

VALUE

VALUE

76 2-WAY AUDIO 0= NONE; 1 = LISTEN; 2 = 2-WAY MANUAL; 3 = 2-WAY FULL DUPLEX 0

78 VOICE RESPONSE FROM KEYPAD SPEAKER 0 = VOICE RESPONSE DISABLED 1 = VOICE RESPONSE ENABLED 0

100 REMOTE PROGRAMMING LOCKOUT 0 = UNLOCK; 1 = LOCK 0

101 CALL LIMITER 0 = OFF; 1 = FIVE CALLS PER ARMING PERIOD 0

103 DIALING DELAY 0 = NO DELAY; 1 = 30 SECOND DELAY 0

104 DIALING METHOD 0 = TONE; 1 = PULSE 0

107 COMMUNICATOR ENABLE 0 = COMMUNICATOR OFF; 1 = COMMUNICATOR ON 0

General Communicator Programming Table

Page 39 of the Linear DUAL 824 user manual — 0 FOR UNLOCK 1 FOR LOCK
Page 39 · click to enlarge
Page 39

GENERAL COMMUNICATOR OPTIONS

COMMUNICATOR ENABLE

✦ The factory setting for the Control Panel disables

the communicator. If the system is going to be a non-monitored, local alarm only, leave the communicator disabled. STEP #107 If the system is going to be monitored by a

PROGRAMMING STEP #107

Central Station, enable the communicator with this programming step.

0 FOR COMMUNICATOR OFF 1 FOR COMMUNICATOR ON

STORES VALUE - 1 BING

2-WAY AUDIO ✦ When the Model VB-2 voice module is installed,

the communicator can provide 2-way audio capability. ✦ The audio module can be programmed for

listen-only, 2-way manual operation (using a pushbutton telephone at the Central Station), and 2-way full duplex hands free operation. ✦ Refer to the VB-2 installation instructions for

PROGRAMMING STEP #76

details on operating the audio module. ✎ NOTE: The Model VB-2 digital voice response

ENTERS STEP NUMBER 0 FOR NO AUDIO MONITORING 1 FOR LISTEN-ONLY 2 FOR 2-WAY MANUAL 3 FOR 2-WAY FULL DUPLEX STORES VALUE - 1 BING

module must be installed for this option to function. ✦ The factory setting for the VB-2 audio module is OFF. STEP #76 The audio module can be set for (1) listen-only, (2)

2-way manual, (3) 2-way full duplex using this step. ✎ NOTE: For safety, 2-way audio will not activate if

the system is disarmed with the duress code. ✎ NOTE:Units programmed for two-way duplex can

still be controlled manually by pressing the “1” or “3” key. In addition, the Central Station can return the unit to two-way duplex by pressing the “8” key.

VOICE RESPONSE

✦ The Control Panel can be programmed to allow

the keypad(s) speaker to play audio produced by the VB-2 digital voice response module. ✦ This selection can also be used when a remote

PROGRAMMING STEP #78

speaker is connected to the Control Panel. ✦ The factory setting is to disable the keypad(s)

speaker from playing voice module audio. STEP #78 The Control Panel can be programmed to enable

0 FOR NO VOICE RESPONSE 1 FOR VOICE RESPONSE

voice module audio using this step. ✎ NOTE: Turning voice response OFF with this

STORES VALUE - 1 BING

programming step will only effect the audio produced by the voice module. It will not stop the keypad(s) speaker from sounding local sirens and tones. ✎ NOTE: A Model VB-2 digital voice response module

must be installed for this option to function.

REMOTE LOCKOUT

✦ The factory setting for the communicator allows

remote connection to the Control Panel with Linear's RA-2400 Remote Access Software and a modem (unlocked). STEP #100 The Control Panel can be programmed to not

PROGRAMMING STEP #100

answer incoming calls, thereby, not allowing remote access (locked) using this step.

0 FOR UNLOCK 1 FOR LOCK

STORES VALUE - 1 BING

Page 40 of the Linear DUAL 824 user manual — 0 FOR TONE DIALING 1 FOR PULSE DIALING
Page 40 · click to enlarge
Page 40

CALL LIMITER

✦ The factory setting for the call limiter is OFF.

This allows the communicator to report burglary alarms, once for each sensor, as many times as they are triggered. STEP #101 The Control Panel can be programmed to only

PROGRAMMING STEP #101

allow fi ve burglary reports total per arming period using this step. ✎ NOTE: Sensors programmed for 24-hour functions

0 FOR OFF (UNLIMITED) 1 FOR ON (5 VIOLATIONS)

(Emergency, Panic, Fire) always send a Central Station report and always sound the local siren regardless of the Call Limiter setting.

STORES VALUE - 1 BING

DIALING DELAY

✦ The factory setting will cause the communicator

to dial the Central Station instantly when an alarm or supervisory event occurs. STEP #103 The communicator can be programmed to

PROGRAMMING STEP #103

wait 30 seconds before dialing using this step. This gives the user time to disarm the system and prevent communications in the case of a subscriber generated false alarm.

0 FOR NO DELAY 1 FOR 30 SECOND DELAY

STORES VALUE - 1 BING

DIALING METHOD

✦ The factory setting causes the communicator to

dial using DTMF (dual-tone multi-frequency) tone dialing. STEP #104 The communicator can be programmed to use

PROGRAMMING STEP #104

pulse (rotary) dialing using this step. Use this option if the telephone line in the installation does not support tone dialing.

0 FOR TONE DIALING 1 FOR PULSE DIALING

STORES VALUE - 1 BING

Page 41 of the Linear DUAL 824 user manual — 86 CALL ROUTING
Page 41 · click to enlarge
Page 41

COMMUNICATOR REPORTING OPTIONS

Linear DUAL 824 — COMMUNICATOR REPORTING OPTIONS diagram (page 41)
Fig. 50

to report using the 4 BY 2 FORMAT. This format allows four-digit account numbers from 0000 to 9999 and provides two-digit alarm codes. STEP #105 ADEMCO CONTACT ID can be chosen as a

reporting format using this step. This format allows 4-digit account numbers from 0000 to 9999 and provides verbose report descriptions with Ademco Contact ID compatible Central Stations.

0 FOR 4 BY 2 1 FOR ADEMCO CONTACT ID

CALL ROUTING

✦ The communicator can be programmed with

three telephone numbers; primary, secondary, and supervisory. ✦ The factory setting for the communicator is to

Linear DUAL 824 — CALL ROUTING diagram (page 41)
Fig. 51

route all calls to the primary telephone number. If communication is unsuccessful after fi ve attempts to the primary number, the secondary number will be dialed for an additional fi ve attempts. If the secondary number cannot be reached, the communicator will “sleep” for fi ve minutes before starting the call process over again. A total of four sleep cycles (50 call attempts) can occur before the communicator stops calling. STEP #86 The communicator can be programmed to report

0 FOR ALL CALLS TO PRIMARY/SECONDARY 1 FOR ALARMS ONLY TO PRIMARY/SECONDARY

supervisory events (low battery, trouble, AC failure, etc.) to the supervisory telephone number instead of the primary or secondary telephone numbers using this step.

✎ CAUTIONIf the page alert user code feature

is going to be used, the supervisory number is reserved for the pager number. DO NOT SET THE CALL ROUTING OPTION TO “1”.

✎ NOTETo disable supervisory reports, set call

routing option to “1” and remove the supervisory telephone number.

✎ NOTEDo not program the primary and secondary

telephone numbers the same. See the FCC Telephone Rules and Regulations on the rear cover of this manual.

COMMUNICATOR REPORTING OPTIONS

STEP

PROGRAMMING

POSSIBLE

FACTORY

INSTALLATION

FUNCTION

VALUES

VALUE

VALUE

0 = ALL CALLS TO PRIMARY OR SECONDARY NUMBER 1 = ALL ALARM CALLS TO PRIMARY OR SECONDARY NUMBER AND ALL OTHERS TO SUPERVISORY NUMBER

86 CALL ROUTING

88 ACCOUNT NUMBER 4 DIGITS EMPTY

89 PRIMARY PHONE NUMBER UP TO 20 DIGITS EMPTY

90 SECONDARY PHONE NUMBER UP TO 20 DIGITS EMPTY

91 SUPERVISORY/PAGER PHONE NUMBER UP TO 20 DIGITS EMPTY

PRESSING THE (A) KEY INSERTS A 1-SECOND DELAY THE [FIRE] KEY INSERTS A 5-SECOND DELAY FOR ALL PHONE NUMBERS ⇒ ⇒ ⇒ THE [CHIME] KEY INSERTS A “*” THE (A) KEY INSERTS A “#” IF IT IS THE LAST DIGIT OF THE PHONE NUMBER

105 REPORTING FORMAT 0 = 4 BY 2; 1 = ADEMCO 0

108 REPORT SYSTEM TROUBLE 0 = NO; 1 = YES 0

110 REPORT FORCE ARMING 0 = NO; 1 = YES 0

111 OPEN/CLOSE 0 = NO; 1 = YES; 2 = MASTER PAC ONLY 0

113 POINT ID REPORTING FOR 4 BY 2 FORMAT 0 = NO; 1 = YES 1

Communicator Reporting Option Table

#

Page 42 of the Linear DUAL 824 user manual — ADDS A POUND (#) CHARACTER (END OF NUMBER)
Page 42 · click to enlarge
Page 42

ACCOUNT NUMBER

✦ The account number entered for the

PROGRAMMING STEP #88

communicator must be 4-digits long. ✦ The factory setting for the account number is

0000. STEP #88 Enter an account number from 0000 to 9999

4-DIGIT ACCOUNT NUMBER

using this step.

STORES VALUE - 1 BING

PRIMARY TELEPHONE NUMBER

✦ The primary Central Station telephone number

PROGRAMMING STEP #89

can be up to 20-digits long. ✦ Digits 0-9 can be used. ✦ Delays and special characters can be entered in

the telephone number (see below). STEP #89 Enter the primary telephone number using this

UP TO 20 DIGITS FOR THE PRIMARY NUMBER

step.

STORES VALUE - 1 BING

SECONDARY TELEPHONE NUMBER

✦ The secondary Central Station telephone

number can be up to 20-digits long. ✦ Digits 0-9 can be used. ✦ Delays and special characters can be entered in

PROGRAMMING STEP #90

the telephone number (see below). STEP #90 Enter the secondary telephone number using this

UP TO 20 DIGITS FOR THE SECONDARY NUMBER

step. ✎ NOTETo remove the secondary telephone

STORES VALUE - 1 BING

number, enter step number 90 then press TEST.

SUPERVISORY OR PAGER TELEPHONE NUMBER

✦ The supervisory Central Station or pager

telephone number can be up to 20-digits long. ✦ Digits 0-9 can be used. ✦ Delays and special characters can be entered

PROGRAMMING STEP #91

in the telephone number (see below). If this is a pager number, enter enough delays for the phone to answer. Then, enter the number to be dialed. ✦ End a pager number with the completion

UP TO 20 DIGITS FOR THE SUPERVISORY/PAGER NUMBER STORES VALUE - 1 BING

character (usually a pound (#) character). STEP #91 Enter the supervisory or pager telephone number

using this step. ✎ NOTETo remove the supervisory/pager telephone

number, enter step number 91 then press TEST.

TELEPHONE NUMBER DELAYS AND SPECIAL CHARACTERS

✦ When creating telephone numbers with

programming Steps 89, 90, & 91, use the following keys to add dialing delays or special characters. ✦ Press the key to place a 1-second dialing delay at the start or anywhere in the middle of the telephone number. ✦ Pressing the key as the last digit of the telephone number will place a pound character at the end of the telephone number. ✦ Press the FIRE key to place a 5-second dialing

ADDS A 1-SECOND DELAY (START OR MIDDLE OF NUMBER)

ADDS A POUND (#) CHARACTER (END OF NUMBER)

ADDS A 5-SECOND DELAY (ANYWHERE IN NUMBER)

ADDS A STAR ( ) CHARACTER (ANYWHERE IN NUMBER)

delay anywhere in the telephone number. ✦ Press the CHIME key to place a star character anywhere in the telephone number.

Page 43 of the Linear DUAL 824 user manual — STORES VALUE - 1 BING
Page 43 · click to enlarge
Page 43

REPORT CONTROL PANEL TROUBLE

✦ The factory setting does not report Control Panel

trouble events to the Central Station. STEP #108 The communicator can be programmed to

PROGRAMMING STEP #108

report Control Panel trouble events using this step. These include all conditions that light the keypad(s) BATTERIES or TROUBLE indicator. It also includes low Control Panel backup battery.

0 FOR NO CONSOLE TROUBLE 1 FOR CONSOLE TROUBLE

STORES VALUE - 1 BING

REPORT FORCE ARMING

✦ The factory setting does not send force arming

reports. STEP #110 The communicator can be programmed to report

force arming anytime the Control Panel is armed with one or more bypassed sensors using this step. ✦ The factory set reporting code for force arming is

PROGRAMMING STEP #110

“65” (Code 574 with Ademco). ✎ NOTE: If force arming is enabled, and the Control

0 FOR NO FORCE ARMING RPTS. 1 FOR FORCE ARMING RPTS.

Panel is force armed (armed with an open sensor) remotely by telephone, or with the RA-2400 Remote Access software, the caller will be disconnected if the communicator is enabled.

STORES VALUE - 1 BING

OPENING AND CLOSING REPORTS

✦ The factory setting does not send opening and

closing reports. STEP #111 The communicator can be programmed to send

an opening report when the system is disarmed, and a closing report when the system is armed for all users, or just the master user using this step. ✎ NOTE 1: For commercial installations with retail

PROGRAMMING STEP #111

traffi c using opening and closing reports, it is recommended to disable quick arming to prevent customers from arming the system. ✎ NOTE 2: The reporting codes are fi xed for opening

0 FOR NO OPEN/CLOSE REPORTS 1 FOR O/C RPTS. FOR ALL USERS 2 FOR O/C RPTS. FROM MASTER USER ONLY

and closing. A unique code is reserved for the master user code and each of the fi ve restricted user codes. ✎ NOTE 3: Arming or disarming with the page

STORES VALUE - 1 BING

alert user code dials the supervisory number, no opening or closing report is sent.

POINT ID REPORTING

✦ The factory setting enables Point ID and allows

the communicator to send two-digit alarm and trouble codes for each sensor. The individual sensor that causes an alarm or trouble report can be identifi ed at the Central Station. STEP #113 Point ID can be disabled using this step. The

PROGRAMMING STEP #113

Central Station will only receive general alarm and trouble reports.

0 FOR GENERAL REPORTS ONLY 1 FOR POINT ID REPORTING

STORES VALUE - 1 BING

Page 44 of the Linear DUAL 824 user manual — GENERAL REPORTING CODES
Page 44 · click to enlarge
Page 44

COMMUNICATOR REPORTING CODES ✦ The 4 by 2 two-digit communicator reporting

Linear DUAL 824 — 1. THE DUAL 824 SECURITY SYSTEM diagram (page 44)
Fig. 52

code for each event has a factory set value. These values may be customized to fi t the specifi c installation and the reporting requirements of the Central Station monitoring the system. ✦ If Point ID reporting is enabled (the factory

default setting), each sensor can report a unique alarm and trouble code. ✦ If Point ID is disabled, the “general” reporting

codes for each event type will be used. ✦ Each programming function is performed with

similar keystrokes. After the system is in Setup Mode, enter the programming step number and press HOME, then enter the new value and press AWAY. For reference, follow the fi gures next to the programming steps. ✴ If the new value is accepted, a “Bing” will sound. If the

new value is not accepted, a “Double Buzz” will sound. ✦ Making a value 0 causes the event not to

communicate to the Central Station. ✎ NOTE: The reporting codes are fi xed for opening

Linear DUAL 824 — 1. THE DUAL 824 SECURITY SYSTEM diagram (page 44)
Fig. 53

and closing. A unique code is reserved for the master and the fi ve restricted user codes. See the Opening & Closing Reporting Codes Table.

GENERAL REPORTING CODES

✦ Use program Steps #201 - 206 to change the

Linear DUAL 824 — GENERAL REPORTING CODES diagram (page 44)
Fig. 54

communicator reporting codes when Point ID is disabled. ✦ Refer to the General Reporting Codes table to

view/edit the reporting codes for each of the fi ve events. The factory settings are listed, along with a blank area to write in the new installation values. STEPS #201-206

Any value from 0-99 can be programmed for each event using these steps (enter “0” to stop an event from reporting). ✎ NOTE: Be careful not to duplicate codes unless the

Central Station requires specifi c codes for certain types of events.

Linear DUAL 824 — GENERAL REPORTING CODES diagram (page 44)
Fig. 55

STEP # PROGRAMMING FUNCTION POSSIBLE 4 BY 2 VALUES FACTORY 4 BY 2 VALUES INSTALLATION 4 BY 2 VALUE

201 GENERAL FIRE REPORT CODE 0 - 99 1

202 GENERAL EMERGENCY REPORT CODE 0 - 99 2

203 GENERAL SILENT PANIC REPORT CODE 0 - 99 3

204 GENERAL BURGLARY REPORT CODE 0 - 99 4

206 GENERAL TROUBLE REPORT CODE 0 - 99 6

General Reporting Codes Table

Page 45 of the Linear DUAL 824 user manual — FACTORY 4 BY 2 VALUES ADEMCO VALUE INSTALLATION
Page 45 · click to enlarge
Page 45

SYSTEM REPORTING CODES

✦ Refer to the System Reporting Codes table to

view/edit the reporting codes for the keypad FIRE and EMERGENCY buttons and for each of the three Control Panel conditions. The factory settings are listed, along with a blank area to write in the new installation values. STEPS #261-266

PROGRAMMING STEPS #261 - 266

0 - 99 FOR SYSTEM REPORTING CODE

Any value from 0-99 can be programmed for each event using these steps (enter “0” to stop an event from reporting).

STORES VALUE - 1 BING

FORCE ARMING REPORTING CODE

✦ The factory set reporting code for force arming is

“65” (Code 574 with Ademco). STEP #258 Any value from 0-99 can be programmed for this

PROGRAMMING STEP #258

event using this step (0 = no report). ✎ NOTE: For force arming reporting, force arming

reports must be enabled. See Page 41.

0 - 99 FOR FORCE ARMING REPORTING CODE

STORES VALUE - 1 BING

DURESS REPORTING CODE

✦ The factory set reporting code for Duress is “66”

(Code 121 with Ademco). STEP #259 Any value from 0-99 can be programmed for this

PROGRAMMING STEP #259

event using this step (0 = no report). ✎ NOTE: For duress code reporting a keypad duress

code must be programmed. See Page 34.

0 - 99 FOR DURESS CODE

STORES VALUE - 1 BING

SYSTEM REPORTING CODES

STEP # PROGRAMMING FUNCTION POSSIBLE 4 BY 2 VALUES

FACTORY 4 BY 2 VALUES ADEMCO VALUE INSTALLATION

4 BY 2 VALUE

258 FORCE ARMING REPORT CODE 0 - 99 65 574

259 DURESS REPORT CODE 0 - 99 66 121

261 SYSTEM FIRE REPORT CODE 0 - 99 68 110

262 SYSTEM EMERGENCY REPORT CODE 0 - 99 69 120

263 SYSTEM TEST/CANCEL REPORT CODE 0 - 99 70 406

264 SYSTEM LOW BATTERY RESTORAL REPORT CODE 0 - 99 71 R302

265 SYSTEM LOW BATTERY CODE 0 - 99 73 E302

System Reporting Codes Table

Linear DUAL 824 — FACTORY 4 BY 2 VALUES ADEMCO VALUE INSTALLATION diagram (page 45)
Fig. 56

MASTER USER CODE1 74 82 R401 C000 E401 C000

RESTRICTED USER CODE #1 75 83 R401 C001 E401 C001

RESTRICTED USER CODE #2 76 84 R401 C002 E401 C002

RESTRICTED USER CODE #3 77 85 R401 C003 E401 C003

RESTRICTED USER CODE #4 78 86 R401 C004 E401 C004

RESTRICTED USER CODE #5 79 87 R401 C005 E401 C005

PAGE ALERT USER CODE (DIALS PAGE NUMBER ONLY, NO CODES REPORTED)

REMOTE/HARDWIRE ARM (SENSOR FCN. 9) & QUICK ARM 81 R407 C007

Opening & Closing Reporting Codes Table

Page 46 of the Linear DUAL 824 user manual — STORES VALUE - 1 BING
Page 46 · click to enlarge
Page 46

4 BY 2 FORMAT POINT ID REPORTING CODES

4 BY 2 FORMAT POINT ID ALARM REPORT CODES ✦ Refer to the 4 by 2 Format Point ID Reporting

Code table to view/edit the alarm reporting codes for each of the 24 sensors. The communicator will send these codes if Point ID is enabled and any sensor triggers an alarm. The factory settings are listed, along with a blank area to write in the new installation values. ✦ Use program Steps #210 - 233 to change the

PROGRAMMING STEPS #210 - 233

4 by 2 Point ID alarm reporting codes. ✎ NOTE: Be careful not to duplicate codes unless the

0 - 99 FOR SENSOR ALARM CODE

Central Station requires specifi c codes for certain types of sensors. STEPS #210-233

STORES VALUE - 1 BING

Any value from 0-99 can be programmed for each event using these steps (enter “0” to stop an event from reporting).

4 BY 2 FORMAT POINT ID TROUBLE REPORT CODES ✦ Refer to the 4 by 2 Format Point ID Reporting

Code table to view/edit the trouble reporting codes for each of the 24 sensors. The communicator will send these codes if Point ID is enabled and any sensor has a low battery or trouble condition. The factory settings are listed, along with a blank area to write in the new installation values. ✦ Use program Steps #234 - 257 to change the

PROGRAMMING STEPS #234 - 257

0 - 99 FOR SENSOR TROUBLE CODE

4 by 2 Point ID trouble reporting codes. ✎ NOTE: Be careful not to duplicate codes unless the

STORES VALUE - 1 BING

Central Station requires specifi c codes for certain types of sensors. STEPS #234-257

Any value from 0-99 can be programmed for each event using these steps (enter “0” to stop an event from reporting).

Page 47 of the Linear DUAL 824 user manual — 1. THE DUAL 824 SECURITY SYSTEM
Page 47 · click to enlarge
Page 47
Linear DUAL 824 — 1. THE DUAL 824 SECURITY SYSTEM diagram (page 47)
Fig. 57

STEP # PROGRAMMING FUNCTION POSSIBLE 4 BY 2 VALUES FACTORY 4 BY 2 VALUE INSTALLATION 4 BY 2 VALUE

210 SENSOR 1 ALARM REPORT CODE 0 - 99 11

211 SENSOR 2 ALARM REPORT CODE 0 - 99 12

212 SENSOR 3 ALARM REPORT CODE 0 - 99 13

213 SENSOR 4 ALARM REPORT CODE 0 - 99 14

214 SENSOR 5 ALARM REPORT CODE 0 - 99 15

215 SENSOR 6 ALARM REPORT CODE 0 - 99 16

216 SENSOR 7 ALARM REPORT CODE 0 - 99 17

217 SENSOR 8 ALARM REPORT CODE 0 - 99 18

218 SENSOR 9 ALARM REPORT CODE 0 - 99 19

219 SENSOR 10 ALARM REPORT CODE 0 - 99 20

220 SENSOR 11 ALARM REPORT CODE 0 - 99 21

221 SENSOR 12 ALARM REPORT CODE 0 - 99 22

222 SENSOR 13 ALARM REPORT CODE 0 - 99 23

223 SENSOR 14 ALARM REPORT CODE 0 - 99 24

224 SENSOR 15 ALARM REPORT CODE 0 - 99 25

225 SENSOR 16 ALARM REPORT CODE 0 - 99 26

226 SENSOR 17 ALARM REPORT CODE 0 - 99 27

227 SENSOR 18 ALARM REPORT CODE 0 - 99 28

228 SENSOR 19 ALARM REPORT CODE 0 - 99 29

229 SENSOR 20 ALARM REPORT CODE 0 - 99 30

230 SENSOR 21 ALARM REPORT CODE 0 - 99 31

231 SENSOR 22 ALARM REPORT CODE 0 - 99 32

232 SENSOR 23 ALARM REPORT CODE 0 - 99 33

233 SENSOR 24 ALARM REPORT CODE 0 - 99 34

234 SENSOR 1 TROUBLE REPORT CODE 0 - 99 41

235 SENSOR 2 TROUBLE REPORT CODE 0 - 99 42

236 SENSOR 3 TROUBLE REPORT CODE 0 - 99 43

237 SENSOR 4 TROUBLE REPORT CODE 0 - 99 44

238 SENSOR 5 TROUBLE REPORT CODE 0 - 99 45

239 SENSOR 6 TROUBLE REPORT CODE 0 - 99 46

240 SENSOR 7 TROUBLE REPORT CODE 0 - 99 47

241 SENSOR 8 TROUBLE REPORT CODE 0 - 99 48

242 SENSOR 9 TROUBLE REPORT CODE 0 - 99 49

243 SENSOR 10 TROUBLE REPORT CODE 0 - 99 50

244 SENSOR 11 TROUBLE REPORT CODE 0 - 99 51

245 SENSOR 12 TROUBLE REPORT CODE 0 - 99 52

246 SENSOR 13 TROUBLE REPORT CODE 0 - 99 53

247 SENSOR 14 TROUBLE REPORT CODE 0 - 99 54

248 SENSOR 15 TROUBLE REPORT CODE 0 - 99 55

249 SENSOR 16 TROUBLE REPORT CODE 0 - 99 56

250 SENSOR 17 TROUBLE REPORT CODE 0 - 99 57

251 SENSOR 18 TROUBLE REPORT CODE 0 - 99 58

252 SENSOR 19 TROUBLE REPORT CODE 0 - 99 59

253 SENSOR 20 TROUBLE REPORT CODE 0 - 99 60

254 SENSOR 21 TROUBLE REPORT CODE 0 - 99 61

255 SENSOR 22 TROUBLE REPORT CODE 0 - 99 62

256 SENSOR 23 TROUBLE REPORT CODE 0 - 99 63

257 SENSOR 24 TROUBLE REPORT CODE 0 - 99 64

4 by 2 Format Point ID Reporting Code Table

Page 48 of the Linear DUAL 824 user manual — IMPORTANT INFORMATION
Page 48 · click to enlarge
Page 48

IMPORTANT INFORMATION

LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twelve (12) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear's normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer's warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

FIRE EVACUATION PLANNING For systems that include fi re protection, UL requires that the following information be available to the users of the system.

✶ Draw up a fl oor plan showing two exits for each room.

The following procedures are to be discussed with the family:

➀ Status of bedroom doors. ➁ Familiarity with alarm signals. ➂ Testing of door during a fi re and use of alternate escape route if door

is hot to touch. ➃ Crawling and holding breath. ➄ Escape fast. No stopping for packing. ➅ Meet at designated outdoor spot. ➆ Emphasize that no one is to return to a burning house. ➇ Fire department notifi cation from a neighbor's phone. ➈ Periodic rehearsal is to be conducted.

WIRELESS PRODUCT NOTICE Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling. However, there are some limitations which must be observed.

INDUSTRY CANADA NOTICES NOTICE: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5. NOTICE: The Industry Canada label identifi es certifi ed equipment. This certifi cation means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certifi ed equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particulary important in rural areas. CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

✶ For U.S. installations onlyThe radios are required to comply with

FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range. ✶ A receiver cannot respond to more than one transmitted signal at a

time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. ✶ Changes or modifi cations to the device may void FCC compliance. ✶ Infrequently used radio links should be tested regularly to protect

against undetected interference or fault. ✶ A general knowledge of radio and its vagaries should be gained prior

to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.

FCC NOTICE This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

✶ Relocate the Control Panel away from the TV/radio receiver. ✶ Plug the Control Panel into a different wall outlet so that the Control

Panel is on a different branch circuit. ✶ Re-orient the TV/radio antenna. ✶ If necessary, the user should consult the dealer or an experienced

radio/television technician for additional suggestions.

FCC TELEPHONE RULES AND REGULATIONS The FCC requires that this alarm dialer system not make more than 15 repetitive dialing attempts to a single telephone number. There are no limitations when the calls are made sequentially to two or more alternative numbers, or when these calls are spaced 10 minutes apart to a single number. The FCC Rules and Regulations do not specify the re-attempt period as this can vary for specifi c applications. When setting this period, take into consideration local, interstate, foreign and special network call completion characteristics, network processing time, a suffi cient number of rings and busy/don't answer modes.

Copyright © 2008 Linear LLC 217703 D

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linear DUAL 824

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear DUAL 824

Be the first to ask — other owners or our team will answer.

Original document

Linear DUAL 824 manual PDF

48 pages·4 MB·Home Security System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…