Telephone Entry & Access Control System
Installation Instructions
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340

Contents Introduction The Model AE1000Plus Telephone Entry & Access Control System is designed for use as a primary access control device for gated communities, parking garages, offi ce buildings, apartments, dormitories, hotels/motels, commercial buildings and recreational facilities. Housed in a locked, rugged stainless steel faced enclosure, the AE1000Plus features a side-lit 12-key telephone style keypad with bright, easy-to-read graphics, a backlit two-line directory display with programmable welcome message, a built-in microphone, speaker, and provision for an optional color CCTV camera. The cabinet is monitored with a magnetic “tamper” switch. The four relay output channels can be programmed to control electric door strikes, magnetic locks, door & gate operators, or barrier gates. The system utilizes hands-free, full duplex telephone communications between visitors and residents for granting access. Complete access control event logging, access time restriction, access location restriction, and administration functions are also available to manage the installation. The AE1000Plus is network ready. Multiple units can be interconnected on a 3-wire RS-485 network or through modems. The AE1000Plus can be used in mixed networks with its sister products, the AE2000Plus and AM3Plus. Two Wiegand inputs are available for connection of 26, 30, or 31-bit Wiegand devices (card readers, etc.). Three sets of PBUS inputs are available for connection to Linear’s line of remote accessories.
Introduction 2 Operation 2 Programming and Cardholder Maintenance 2 Hardware Features 3 Software Highlights 3 Feature Overview 3 Accessory Overview 4 PBUS Accessories 4 Wiegand Accessories 4 Component Locations 5 Wiring Diagram 6 Important Mounting Requirements 7 Entry System Mounting 8 Relay Output Wiring 10 Power, Battery, & Ground Wiring 11 RS-232 Port 11 Telephone Wiring 12 Optional Radio Antenna 12 Optional Postal Lock 13 Optional Color CCTV Camera 13 PBUS Accessories 14 Wiegand Accessories 14 Optional Network Connection 15 System Adjustments 18 System Diagnostics 18 Internal Controls 19 AE1000Plus Operation 20 Specifi cations 21 Dimension Drawing 21 Troubleshooting 22 Linear Limited Warranty 23 FCC Notice 23
Operation In a typical installation, the unit’s memory would be programmed with each resident’s name and directory code number. Arriving visitors would use the keypad on the AE1000Plus to view the directory names and directory number for the desired resident. Upon entering the directory number, the AE1000Plus will automatically dial the resident’s telephone number and establish two-way voice communication between the visitor and the resident. The resident will then have the option to grant or deny access to the visitor by pressing a digit on their telephone. In addition to the telephone entry, the AE1000Plus can grant access using entry codes at the local or remote keypads. Also remote receivers, card readers, and interior and exterior keypads can be used with the system. Block coded MegaCode® transmitters can be used to gain access through the AE1000Plus’s built-in or remote radio receivers. Each transmitter can be individually suspended or re-activated. The system’s clock/calendar can control access based on specifi c times and dates. Automatic relay activation can be scheduled. Access can be restricted to certain times and dates. Holiday access can be scheduled. The system’s event log records system activity for future reference.
Programming and Cardholder Maintenance Two programming methods can be used with the system: Linear’s AXNET or AccessBase2000. Each has its advantages, but only one must be chosen at the onset for each installation. Once a unit is programmed with one method, all programming data will be lost if a decision is made to switch to the other method. Linear’s AXNET software is built into each unit. It allows connecting to the unit using common browser software from any PC at any location. Each unit’s database is stored in the unit’s memory. Linear’s AccessBase2000 software installs in one dedicated PC and is designed with many extra features usually for large network installations. The database for the entire system is stored in the dedicated PC.
Throughout this manual, multiple-unit networks are referenced. Depending on the programming method used, networks can contain the following model units:

Feature Overview Relay Outputs
Variable gain, high-sensitivity receiver for wireless transmitters ✓ FOUR FORM “C” (N.O. & N.C) RELAYS
Four 3-amp dry contact relay outputs are provided to activate access devices, such as door strikes, magnetic locks, automatic doors, barrier gates, and automatic sliding gates. The relay outputs can also be used as specialty outputs for alarm contact shunting, operator obstacle triggering, and alarm activation. Each of the relays can also be manually activated from buttons on the AE1000Plus circuit board. LED indicators display the status of each relay. Request-to-Exit Inputs
Each relay has 3-amp @ 24-volt rating ✓ FOUR REQUEST-TO-EXIT INPUTS
Activates access device for exiting using a hardwired switch ✓ FOUR SENSING INPUTS
For sensing door position to control door-ajar and alarm features, or for access inhibit timer ✓ BUILT-IN ANNUNCIATOR
Each relay channel has a request-to-exit input. These inputs are supplied for hardwire activation of the access devices. Typically a request-to-exit input is wired to a pushbutton inside of the access controlled area. When a person desires to exit, pressing the pushbutton will activate the output relay channel and trigger the access device. A loop detector for automatic gate operation can be connected to a request-to-exit input. Sensing Inputs
Chirps during keystrokes ✓ BUILT-IN MODEM
No add-on modem required for telephone communications with system ✓ RS-232 PORT
COM port for direct connection to a computer ✓ NETWORK SUPPORT
Multiple units can be connected together to share data ✓ EXPANSION INTERFACE SUPPORT
The sensing inputs connect to door switches that monitor whether the controlled door is open or closed. The sensing inputs may alternately be programmed as “access inhibit” inputs for use with an external timer or service switch. Built-in Modem
Model AM-MIO accessory adds additional input and outputs to the AE1000Plus ✓ ON-BOARD CLOCK/CALENDAR CIRCUIT
Stamps the event log data as it is stored in the system’s memory ✓ WIEGAND INPUTS
A modular connector is provided for telephone line connection to the unit’s built-in 33.6K baud modem. The system can be accessed remotely for programming and control over the standard telephone system using a personal computer with a modem. For system backup, a computer connected through the modem can store and retrieve the AE1000Plus’s memory data. RS-232 Communications Port
Two Wiegand format card reader inputs for connection to external devices. ✓ LINEAR PBUS SUPPORT
Three PBUS input/output ports for connection of up to 6 Linear accessories. ✓ CCTV COLOR CAMERA SUPPORT
Model CCM-1 accessory camera allows color video monitoring of the keypad area ✓ POWER FAILURE MONITOR
A modular connector is provided for the bi-directional 38.4K baud RS-232 port. The AE1000Plus’s RS-232 port connects to a personal computer’s COM port. System programming can be performed locally with a computer connected to the RS-232 port. Local Keypad
AC power input is monitored, power outages are recorded in the event log
No dedicated programmer required, program with a computer and a modem ✓ LARGE ENTRY CODE CAPACITY
The local keypad is the system’s primary keypad. The local keypad activates Relay Channel “A”, but can be programmed for any of the relays. Postal Lock
Up to 20,000 entry codes can be used for gaining access ✓ 2-8 DIGIT ENTRY CODE LENGTH
Flexible code length for different applications ✓ LARGE RESIDENT DIRECTORY CAPACITY
The AE1000Plus cabinet has provisions for installing a U.S.P.S. postal lock for keyed mail carrier access. The postal lock will activate Relay Channel “A”, but can be programmed for any of the relays. Obstacle Detection
Up to 10,000 residents ✓ 2-4 DIGIT DIRECTORY NUMBER LENGTH
Directory number lengths can be customized for small or large installations ✓ LARGE TRANSMITTER CAPACITY
Linear’s Model MGT safety edge transmitter is compatible with the AE1000Plus. The MGT detects and transmits obstacle events to the AE1000Plus. Programming Memory
Up to 45,600 block coded and 20,000 individually enrolled Linear transmitters can be used for gaining access ✓ TRANSMITTER FACILITY CODE SUPPORT
The AE1000Plus fl ash memory retains all entry codes, transmitter information, card access, and programming, even without power. Battery Backup
Identifi es wireless transmitters by installation ✓ LARGE CARD CAPACITY
The system supports a 12-volt battery backup or uninterruptable power supply for operation during power outage. The system does not charge the backup battery, an external battery charger is required to maintain the battery. Network Support
Up to 45,600 block coded and 20,000 individually enrolled cards can be used for gaining access ✓ FOUR INDEPENDENT RELAY CHANNELS
Each output’s action is programmable ✓ PROGRAMMABLE TIME SCHEDULED RELAY ACTIVATION
Activation for up to four time periods for each of the 31 system time zones ✓ PROGRAMMABLE TIME ZONE ACCESS VALIDATION
Multiple AE1000Plus, AE2000Plus, & AM3Plus units can be networked together via three-wire RS-485 cables or through modems allowing information sharing between the units. A common event log is retained for all of the networked units. Linear PBUS Ports
Validation during four time periods for each of the 31 system time zones ✓ PROGRAMMABLE VALIDATION DAYS
Select days of the week access is allowed ✓ PROGRAMMABLE HOLIDAY DAYS
Three 6-wire Linear PBUS input/output ports are available to connect to several accessories (keypads, proximity readers, remote receivers). A typical application for a remote keypad or reader would be to control additional doors or gates.
Select up to 24 expiring & 24 non-expiring holidays for access restriction ✓ OBSTACLE TRANSMITTER SUPPORT
Compatible with Linear’s Model MGT transmitter ✓ EVENT LOG
Stores up to 20,000 system events in memory for record keeping ✓ DELETED CARDHOLDER DATABASE
System logs deleted cardholders for future identifi cation ✓ TIMED OR TRUE ANTI-PASSBACK
Options to temporarily disable a cardholder’s credentials after access for a preset time or depending on the cardholder’s access direction
Hardware Features · Software Highlights

Accessory Overview PBUS Accessories Several compatible accessories are available to connect to the three 6-wire communications “PBUS” inputs. Up to six PBUS accessories can be used with each AE1000Plus unit.
AM-RRR Remote Radio Receiver For wireless transmitters, connect the Model AM-RRR high-gain superheterodyne UHF receiver. The receiver is housed in a weather-resistant enclosure and can be mounted indoors or outdoors. Gaskets and a weather-tight wiring strain relief seal the unit from the elements. AM-RPR Radio Proximity Receiver The Model AM-RPR functions as a remote device that supplies localized radio reception for the AE1000Plus In a typical installation, the AM-RPR would be mounted in a plastic single-gang electrical box next to the controlled opening. When the user requires access, their transmitter must be activated within three inches of the AM-RPR faceplate. AM-KP Exterior Keypad The Model AM-KP is housed in a rugged cast aluminum enclosure designed for exterior installations. The die-cast keys have bright, easy-to-read yellow graphics. The keypad can be mounted to a pedestal or directly to a wall. A keylock secures the keypad to the mounting backplate. AM-KPI Interior Keypad The Model AM-KPI keypad is housed in a rugged, plastic enclosure designed to be mounted indoors in a standard single-gang electrical box. Tamper resistant screws secure the keypad to its mounting plate. The die-cast keys have bright, easy-to-read yellow graphics and is illuminated with white LEDs. The keypad is supplied with a satin-chrome bezel and three interchangeable colored bezels (white, ivory, & bronze) to customize the keypad appearance for the installation. AM-CRI Card Reader Interface The Model AM-CRI expands the standard two AE1000Plus Wiegand inputs by supporting one or two additional 26-bit Wiegand input devices per AM-CRI interface used.
REMOTE
RADIO ANTENNA
AM-RRR REMOTE
RADIO RECEIVER
AM-RRR
AE1000Plus TELEPHONE ENTRY & ACCESS CONTROL
AM-RPR
AM-KP
PBUS ACCESSORIES
WIEGAND ACCESSORIES
AM-KPI
AM-KPI INTERIOR
AM-CRI AM-PR PROXIMITY
KEYPAD
READERS
Wiegand Accessories The two WIEGAND format inputs connect WIEGAND devices to the AE1000Plus. Linear offers a Wiegand format proximity reader. Most other manufacturer’s 26, 30 & 31-bit WIEGAND output devices can also be used with the AE1000Plus.
AM-PR Proximity Reader The Model AM-PR is a radio-based reader that works with either proximity tags (Model AM-PT) or proximity cards (Model AM-PC), both of which are slotted to attach to key rings. Upon reading a user’s tag or card, the reader sends the entry data via a Wiegand output to the AE1000Plus. An integral LED confi rms to the user that access is granted.
KEYPAD
WIEGAND
CARD READERS
AM-PR
AM-RPR
RADIO PROXIMITY
AM-CRI
CARD READER INTERFACE
RECEIVER
* · 0 #


FOR EASY WIRING, THE UNIT'S TERMINAL BLOCKS CAN BE UN-PLUGGED FROM THE CIRCUIT BOARD


THIS WIRING EXAMPLE SHOWS: DOOR ACCESS WITH A DOOR STRIKE ON RELAY CHANNEL "A" DOOR ACCESS WITH A MAGNETIC LOCK ON RELAY CHANNEL "B" GATE ACCESS WITH A GATE OPERATOR ON RELAY CHANNEL "C" (YOUR INSTALLATION MAY VARY)

Mounting Environment Consider the environmental factors at the desired mounting location. The AE1000Plus is designed for direct outdoor installations, however, it is preferable to protect the unit from extreme exposure to sun, driving rain, or snow whenever possible. Mounting the unit in a kiosk can provide extra environmental protection.
Follow Building Codes Check all local building codes and ordinances prior to installing the system. Proper installation of the AE1000Plus conforming to the local building codes for access control equipment is a regulatory requirement. The AE1000Plus installation is an extremely important and integral part of the overall access control system.
?
?
?
?
?
Mounting Location If the AE1000Plus is used to control a door or pedestrian gate, locate the unit as near as practical to the entry point. If the unit is mounted on or in a wall adjacent to the entry point, be sure the wall is sturdy. The repeated shock and vibration from a slamming access door or spring- loaded pedestrian gate must be isolated from the AE1000Plus. NEVER MOUNT THE UNIT DIRECTLY TO A MOVING DOOR OR GATE!
Gate Installations If the AE1000Plus is used to control a gate operator connected to a vehicular gate, the unit MUST be mounted AT LEAST 10 feet away from the gate (open and closed) and gate operator. AT NO TIME SHOULD A PERSON BE ABLE TO TOUCH THE GATE OR GATE OPERATOR AND THE AE1000Plus AT THE SAME TIME.

Vehicle Traffi c Do not mount the AE1000Plus where it extends into any traffi c lane. Locate the gooseneck pedestal or entry kiosk so all parts of the AE1000Plus are outside the traffi c lane. Locate the AE1000Plus clear of any turn-around lanes vehicles use when access is denied.

Americans with Disability Act (A.D.A.) Requirements THE FOLLOWING WHEELCHAIR ACCESS REQUIREMENTS ARE FOR PUBLIC DOOR CONTROL INSTALLATIONS ONLY.
1. If the clear fl oor space allows only forward approach to the system, the maximum high forward reach allowed is 48” above grade to the top of the keypad. 2. If the high forward reach to the system is over an obstruction of greater than 20” but less than 25”, the maximum high forward reach allowed is 44” above grade to the top of the keypad. 3. If the clear fl oor space allows parallel approach by a person in a wheelchair, the maximum high side reach shall be 54” above grade to the top of the keypad. 4. If the high side reach is over an obstruction of 24” or less, the maximum high side reach allowed is 46” above grade to the top of the keypad.

Entry System Mounting The AE1000Plus cabinet is designed to be mounted three ways:

LOOSEN THE TOP TWO NUTS & REMOVE THE BOTTOM TWO NUTS
Mounting Preparation Before mounting the system, the main circuit board mounting plate must be removed to provide access for the wiring hole and mounting fasteners.
CAREFULLY REMOVE THE FOUR WIRING HARNESS CONNECTORS & GROUND WIRE
Surface Mounting The cabinet can be mounted on a wall or any suitable fl at surface. The four 3/8” mounting holes or the four self-drill locations can be used to attach the cabinet to the surface.

1. For wall mounting, hold the cabinet at the approximate mounting location where the display will be about eye level or slightly above. 2A. If using the 3/8” mounting holes, mark the four mounting hole centers. Drill as required. Use the appropriate fasteners for the mounting surface to secure the cabinet. 2B. If using the self-drill mounting holes, choose the correct size bit for the fasteners and drill the cabinet as required. Use the appropriate fasteners for the mounting surface to secure the cabinet. 3. After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire.
ATTACH THE CABINET WITH APPROPRIATE HARDWARE FOR THE MOUNTING SURFACE

Entry System Mounting (Continued) Recessed Mounting The cabinet can be mounted recessed using the accessory trim-ring (P/N ACP00909). The trim-ring mounts in the wall and the cabinet attaches to the trim-ring.

DETERMINE LOCATION FOR THE 13-¼" x 16-¼" MOUNTING HOLE
1. Identify the location of any studs in the wall. 2. Cut a 16-1/4” high by 13-1/4” wide rectangular hole between studs at the mounting location. 3. Install any additional mounting material required to provide surfaces inside the wall 13-1/4” apart for attaching the trim-ring. 4. Place the trim-ring in the wall hole. Check for level, then attach the trim-ring with up to six screws into the side tabs. 5. Drill the cabinet’s four self-drill mounting holes the appropriate size for the hardware. 6. Attach the cabinet to the trim-ring using self-tapping screws. 7. After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire.
4 INSTALL ANY SHIMS TO ALLOW MOUNTING AND ATTACH THE TRIM-RING WITH UP TO 6 SCREWS
DRILL 3/16" HOLES IN THE CABINET AT THE PRE-MARKED LOCATIONS
ATTACH THE CABINET TO THE TRIM-RING WITH SELF-TAPING SCREWS
Pedestal Mounting The cabinet can be mounted on a gooseneck pedestal. Linear manufacturers two pedestals: Model GNC-1 is for surface mounting with concrete fasteners, Model GNB-1 is for burial mounting. When mounting to a pedestal, use the cabinet reinforcing plate to stiffen the cabinet.

ALIGN THE REINFORCING PLATE ON THE INSIDE OF THE CABINET
USE SECURITY HARDWARE TO ATTACH THE PLATE AND CABINET TO THE PEDESTAL

Relay Output Wiring Any of the four relay outputs channels (A-D) can be used to control access devices on doors or gates.
RELAY TERMINALS
ELECTRIC
GND DS N.O. COM N.C.
Door or Pedestrian Gate Control
1. Install a low voltage electric door strike or magnetic lock as a locking device for the door or pedestrian gate. 2. Install the power supply or transformer for the locking device. DO NOT POWER THE AE1000Plus FROM THIS POWER SUPPLY. 3. Connect one wire from the power supply to one wire from the locking device. 4. Route two wires between the locking device and the AE1000Plus. Connect one wire to the remaining wire of the locking device. Connect the other wire to the remaining wire of the power supply. 5A. For a door strike, connect the wires to the AE1000Plus relay COM & N.O. terminals. 5B. For a magnetic lock, connect the wires to the AE1000Plus relay COM & N.C. terminals. Gate Control
RTE
TYPICAL MAGNETIC LOCK HOOKUP
MAGNETIC
GND DS N.O. COM N.C.
LOCK
DOOR
LOCK POWER SUPPLY
RTE
GND DS N.O. COM N.C.
wiring diagram.
Request-to-Exit Inputs Each of the four relay outputs has a request-to-exit input terminal. Grounding this terminal will activate the associated relay. Exit request inputs are typically used with push bars, loop sensors, or pushbuttons.


AC2
AC1
DC
DC
EARTH GROUND
STUD
EARTH GROUND
STAKE 12 VOLT BATTERY
NOTE: THE OPTIONAL
BACKUP BATTERY
WILL REQUIRE AN EXTERNAL CHARGER
AE1000Plus clock/calendar and programming memory during power outages. 1. Route two wires between the AE1000Plus and the backup battery. 2. Connect the Battery positive to the AE1000Plus DC+ terminal and the negative to the DC- terminal. ✦ NOTE: The AE1000Plus does not supply battery charging
current. An external battery charger will be required to maintain the battery.
Earth Ground For the best ground, use size 12 gauge solid wire or larger to connect the to an 8-foot copper ground rod. Locate the ground rod next to the Power and Telephone company rods and bond the rods together with a new clamp. Do not disturb the clamps installed by the Power or Telephone Company. Alternately, connect to a metallic cold water pipe for the earth ground.
COMPUTER'S
COM PORT
SET COMPUTER COM PORT
LINEAR MODEL A2C SERIAL COMPUTER CABLE
BAUD RATE TO 38,400 BPS

Telephone Wiring For telephone entry and programming, the AE1000Plus connects to a standard telephone line.

1A. If using the AE1000Plus modular connector for the telephone connection, connect a double-ended modular cable between the AE1000Plus PHONE jack and the modular telephone jack wired to the installation’s telephone line. 1B. If using the AE1000Plus terminal block for the telephone connection, before connecting the telephone line, check the polarity of the wires with a DC voltmeter. Connect the negative wire (usually green) to the RING terminal. Connect the positive wire (usually red) to the TIP terminal.
Optional Radio Antenna If wireless transmitters are going to be used in the system a remote antenna must be installed to provide reception for the AE1000Plus. A basic antenna kit is supplied with the AE1000Plus. The kit contains a whip antenna, connector, and a 36” length of coax cable. The antenna connector should be mounted on a metal surface using a 3/8” hole. Two other models of antennas are compatible with the AE1000Plus. The Model EXA-1000 is a non-directional antenna. The Model EXA-2000 is a directional antenna used in installations where transmitted signals are desired to be received only in a particular direction.

the antenna to the AE1000Plus. Keep the coax as short as possible. 1. Install the antenna. (See installation instructions if using the EXA-1000 or EXA-2000.) 2. Connect the antenna coax cable to the antenna and route the cable to the AE1000Plus. 3. Connect the cable to the AE1000Plus ANTENNA connector. Receiver Range Control The AE1000Plus has a RECEIVER RANGE adjustment knob. In some installations, it may be necessary to reduce the effective radio range of the receiver to limit the distance that transmitters can be used. Reducing the radio’s sensitivity may also help in installations where unwanted interference is overpowering signals from transmitters.

Optional Postal Lock A postal lock can be installed in the AE1000Plus Entry System to provide keyed access for the postal service. The AE1000Plus case is designed to accept a U.S. Postal Service postal lock. When the postal lock is engaged, the programmed output relay will activate.

1. Remove the four locknuts that retain the postal lock switch plate (above the speaker on the AE1000Plus faceplate). 2. Remove the switch plate, hole cover plate and block from the four studs. The hole cover plate and block will not be used and can be discarded. 3. Install the postal lock assembly onto the four studs. The postal lock’s moving plunger should point towards the middle of the faceplate (see fi gure). 4. Replace the postal lock switch plate with the microswitch oriented inward where it will be pressed by the postal lock’s moving plunger (see fi gure). 5. Secure the postal lock and switch plate with the four locknuts. ✦ NOTE: Be sure the postal lock’s plunger actuates the
REPLACE PLATE WITH THE MICROSWITCH TOWARDS THE FRONT OF THE CABINET, REPLACE LOCKNUTS
microswitch. Adjust the switch plate and the postal lock then test the action until the microswitch fully actuates. 6. Tighten the four locknuts after the adjustment and testing is complete. 7. When programming the system, set the postal lock option to activate the desired relay output.
Optional Color CCTV Camera Linear’s Model CCM-1 (P/N ACP00904) CCTV camera can be installed inside the AE1000Plus Entry System. The camera provides a video signal for viewing the area in front of the entry system. The CAMERA connector is used to connect the camera to the AE1000Plus. The 4-conductor cable routes power to, and video from the camera. The VIDEO jack is the camera output for connection to a video cable with a Type “BNC” connector. Up to 400 feet of 75-ohm RG-59 video cable can be used. Longer cable runs may require the use of a video amplifi er.

1. Remove the two plate locknuts from the camera mounting studs above the right keylock on the AE1000Plus faceplate. 2. Remove the cover plate. 3. Remove the protective backing from the plastic window included with the camera and install the plastic window onto the studs with the adhesive side against the door. 4. Remove the lens cap from the camera. 5. Mount the camera assembly on the two studs, with the alignment hole in the camera bracket towards the top. Secure the camera with the two locknuts. 6. Connect the camera’s cable to the AE1000Plus CAMERA connector. 7. Connect the video cable to the AE1000Plus VIDEO connector. 8. Connect the other end of the video cable to the viewing monitor or the video distribution system.
ATTACH CAMERA WITH TWO NUTS CONNECT CAMERA WIRING HARNESS
Postal Lock Installation · Camera Installation

PBUS Accessories Up to six accessories (keypads, proximity readers, remote receivers) can be connected to the three PBUS input/output ports. A typical application for a remote keypad would be to control a second door or gate. Linear’s PBUS devices compatible with the AE1000Plus are:

Cable choices:
CAT-5e 4-UTP CABLE UP TO 500 FEET PER DEVICE
Wiegand Accessories The two AE1000Plus Wiegand inputs (WIEGAND A & B) can connect to a large variety of 26, 30, and 31-bit Wiegand output accessories. The Wiegand format is a common standard for access control equipment. A typical application would be to add swipe card or proximity readers to the system.


Optional Network Connection Linear’s AE1000Plus, AE2000Plus, & AM3Plus Access Control Systems can be connected together in a network. A network will allow sharing programming and user information between the systems. Program each unit to a different network Node Address (see Page 19).
access control Models AE-1000, AE-2000, & AM3 can be used in networks with the Models AE1000Plus, AE2000Plus, & AM3Plus only using AccessBase2000 software. The built-in AXNET Browser Interface included in the “Plus” models is only compatible with the Models AM3Plus, AE1000Plus, and AE2000Plus.
Network Confi gurations for AXNET Programming If the system is going to be programmed using Linear’s AXNET Browser Interface, units can communicate with each other on the network through modems or RS-485 cable connections. Refer to the fi gure below for details of the 11 supported AXNET network hardware confi gurations and associated Network Confi guration Numbers. After choosing a network layout that best suits the installation, note the Network Confi guration Number. This number is required to be entered during setup of the AXNET Browser Interface in the Global Settings for Networking area.

NETWORK CONFIGURATION #9 2X TWO RS-485 NODES, TWO MODEM NODES

Optional Network Connections (Continued) Network Confi guration for AccessBase2000 Programming If the system is going to be programmed using Linear’s AccessBase2000 software, units communicate with each other on the network through RS-485 cable connections. AccessBase2000 does not support unit-to-unit network communications through modems, only RS-485 cable. AccessBase2000 does support modem communications from the PC to the eight Node #1 “master” units on an AccessBase2000 network. Refer to the fi gure below for design details of a fully implemented AccessBase2000 network. The fi gure shows eight networks, each with eight nodes, for a total of 64 units.


Optional Network Connections (Continued) RS-485 Network Wiring Network wiring conforms to 3-wire RS-485 electrical specifi cations. Units connected in the network can be wired using one unit as a “hub” or by wiring from one unit to the next in “daisy-chain” fashion. See the fi gures for wiring options.

ACCESS CONTROL HOMERUN NETWORK USING ONE UNIT AS A NETWORK MASTER
terminals.
Network Wiring with Hub

Network “Daisy-chain” Wiring

System Adjustments The factory settings are suffi cient for most installations. The system can be adjusted to customize the installation.

Speaker Volume Adjustment If the resident’s voice from the speaker is too loud or not loud enough, the speaker’s volume can be adjusted.
System Diagnostics Several components on the main circuit board are for monitoring the system during operation. When calling for technical assistance, Linear’s Technical Services Department may ask the installer to use these components to diagnose the system.

On-board Indicators 17 LED indicators are on the main circuit board. Refer to the fi gure for the location of each indicator.

Internal Controls On-board Pushbuttons Seven pushbuttons are on the main circuit board. Refer to the fi gure for the location of each pushbutton.
DISPLAY
"UP" BUTTON "DOWN" BUTTON
RELAY "A"
LATCH
RELAY "B"
AE1000PLUS MAIN CIRCUIT BOARD
LATCH
On-board Display The STATUS/PROGRAM display shows the current system conditions and is used for system setup. Power-up When power is applied, the display will show the current mode of operation (AXNET “An” or AccessBase2000 “Ab”) and the version number of the fi rmware installed. The default mode of operation is AccessBase2000. Program Mode Program Mode uses the display and the UP, DOWN, and ENTER pushbuttons. The setting the network node address, operation mode, and clearing the memory can be performed in Program Mode. Refer to the following steps to change the system settings:
LATCH
RELAY "D"
LATCH
STATUS/PROGRAM
DISPLAY
SYSTEM IDLE
1. To enter Program Mode, press and hold the UP and DOWN pushbuttons together for one second. While in Program Mode, both decimal points on the display are lit. 2. The display shows the current network node number setting. 3. Press the UP or DOWN button to cycle the display through the options that can be selected (see Program Mode Display Table). 4. When the desired option is displayed, press the ENTER button to select the option. ✦ NOTE: In network installations, a unique network address
LEFT DIGIT CIRCULATES
PROGRAM MODE
(1-8 for AccessBase2000, 1-4 for AXNET) must be set before communicating with network. ✦ NOTE: If using AXNET for programming the system, select the
An programming option, for AccessBase2000 select Ab. After the option is selected, the system will restart. Status Mode While the system is running, the display will show the current system status. Normally the left digit will show a moving pattern and the right digit will show the unit’s Network Node number. When a supervisory condition exists, the display will cycle to show the condition(s). When an item is displayed, press the ENTER button to clear the display (clears the display only, the condition may still exist). Refer to the following table for the supervisory condition display codes.
DIGITS SHOW SUPERVISORY CODE
PROGRAM MODE DISPLAY
AccessBase2000 MODE AXNET MODE FUNCTION
STATUS MODE DISPLAY DISPLAY CONDITION 01 MGT TRANSMITTER STATUS EXCEPTION 02 MGT TRANSMITTER LOW BATTERY 03 MGT TRANSMITTER TAMPER 04 AC POWER FAIL (BACKUP BATTERY REQUIRED) 05 CHANNEL “A” LOCKED CLOSED 06 CHANNEL “B” LOCKED CLOSED 07 CHANNEL “C” LOCKED CLOSED 08 CHANNEL “D” LOCKED CLOSED 09 MODEM FAILURE
A.N. A.b. SWITCH OPERATION MODE
B.L. B.L. RESERVED (DO NOT USE)
C.L. C.L. CLEAR UNIT’S MEMORY


ENTRY CODE AT REMOTE KEYPAD ENTRY CODE AT LOCAL KEYPAD


ENTER DIRECTORY NUMBER OR PRESS OR SCROLL THROUGH THE RESIDENT NAMES
3 AFTER SCROLLING, ENTER THE RESIDENT'S DIRECTORY NUMBER AND TALK WITH THE RESIDENT
customized for the installation. • The length of time the visitor is allowed to talk can be programmed from 15-255 seconds. The resident will hear a series of beeps during the last 10 seconds of talk time. To restart the talk timer, the resident can press on their telephone.

MECHANICAL Case dimensions: 13” W x 16-1/4” H x 3-1/2” D ELECTRICAL Voltage: 16-24 Volts AC or 12-24 Volts DC Current: 1500 mA @ 16 VAC maximum Backup Battery: Externally charged 12 Volt DC source Outputs: Relay Channels A-D Form “C” 3 Amps @ 30 Volts maximum Inputs: Four normally closed door sense inputs Four normally open exit request inputs Two WIEGAND reader inputs Three PBUS inputs Network: Three-wire network RADIO Frequency: 318 MHz ± 500 KHz @ 23°C Bandwidth: 300 KHz Typical Sensitivity: -97 dBm Minimum (-100 dBm Typical) Encoding: Linear MegaCode® Format ENVIRONMENTAL Temperature: -22°F to 149°F (-30°C to 65°C) Humidity: 5% to 95% non-condensing



1. Check antenna installation and condition if transmitters were previously working well. 2. Check the RADIO indicator on the AE1000Plus circuit board. If it is fl ickering without activating any transmitters there is interference blocking the receiver. Try adjusting the RECEIVER RANGE knob to reduce the receiver’s sensitivity to the interference. 3. Connect an audio amplifi er or telephone buttset to the RECEIVER TEST POINTS (the wire jumpers next to the RECEIVER RANGE knob). Listen to the sounds of the signals being received. If you hear the interference, remove power from possible interfering devices to determine the source of the interference. The antenna or the interfering device may need to be relocated. 4. Use Model FT-1 to check for interference.

Linear Limited Warranty This Linear product is warranted against defects in material and workmanship for twenty-four (24) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
FCC Notice Changes or modifi cations not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Copyright © 2008 Linear LLC 227522 B
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.