EN
LifeSource logo
Official user manual

LifeSource UB-511

11 pages·577 KB·Blood Pressure Monitor·PDF·ENDEFRITNLJA
LifeSource UB-511
Table of Contents 24 sections Wrist Auto-Inflation · Wrist Blood Pressure Monitor · Trilingual Instruction Guide – MODEL UB-511 · IMPORTANT INFORMATION · … ShowHide
Page 1 of the LifeSource UB-511 user manual — Trilingual Instruction Guide – MODEL UB-511
Page 1 · click to enlarge
Page 1
LifeSource UB-511 — Wrist Auto-Inflation diagram (page 1)
Fig. 1 · Wrist Auto-Inflation
LifeSource UB-511 — Wrist Auto-Inflation diagram (page 1)
Fig. 2 · Wrist Auto-Inflation

Wrist Auto-Inflation

Wrist Blood Pressure Monitor

LifeSource UB-511 — Wrist Auto-Inflation diagram (page 1)
Fig. 3 · Wrist Auto-Inflation
LifeSource UB-511 — Wrist Auto-Inflation diagram (page 1)
Fig. 4 · Wrist Auto-Inflation

Trilingual Instruction Guide – MODEL UB-511

Page 2 of the LifeSource UB-511 user manual — IMPORTANT INFORMATION
Page 2 · click to enlarge
Page 2

IMPORTANT INFORMATION

Please read this important information before using your monitor. Please remember that only a medical practitioner is qualified

to interpret your blood pressure measurements. Use of this device should not replace regular medical examinations. Have your physician review your procedure for using this

device. He or she will want to verify blood pressure measure- ments before prescribing or adjusting medications. Consult your physician if you have any doubt about your

readings. Should a mechanical problem occur, contact A&D Medical. Do not attempt to service, calibrate, or repair this device. Because your UB-511 monitor contains delicate, high-

precision parts, avoid exposing it to extremes in temperature or humidity or to direct sunlight, shock and dust. A&D Medical guarantees the accuracy of this device only when it is stored and used within the temperature and humidity ranges noted on page E-15. Clean the monitor and cuff with a dry, soft cloth or a cloth

dampened with water and a mild detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean monitor or cuff. Remove and replace batteries if monitor is not used for more

than six months.

PRECAUTIONS FOR USE The UB-511 is designed to be used at home, by those who are 18 years and older to monitor blood pressure: systolic and diastolic, and pulse rate.

Page 3 of the LifeSource UB-511 user manual — ❤
Page 3 · click to enlarge
Page 3
LifeSource UB-511 — IMPORTANT INFORMATION  diagram (page 3)
Fig. 5
LifeSource UB-511 — IMPORTANT INFORMATION  diagram (page 3)
Fig. 6

WHAT DISPLAY SYMBOLS MEAN E-2 MONITOR COMPONENTS E-3 HOW UB-511 WORKS E-4

Congratulations. You have purchased a LifeSource state-of-the- art blood pressure monitor, one of the most technologically advanced yet easy to use products available in the marketplace today. This LifeSource monitor is designed to make your daily regimen useful and convenient.

BEFORE YOU START E-4

TAKING YOUR BLOOD PRESSURE E-5 — E-6 WHAT IS AN IRREGULAR HEARTBEAT E-7 ABOUT AVERAGE READING E-7 ABOUT MEMORY E-8 ABOUT PRESSURE INDICATOR E-9

Physicians agree that daily self-monitoring of blood pressure is an important way individuals can contribute to maintaining their cardiovascular health and preventing the serious conse- quences of hypertension left undiagnosed and untreated.

A&D Medical has been manufacturing quality healthcare products for more than 20 years. Rest assured that we are committed to providing you and your family with monitoring devices specifically designed for high accuracy and ease of use.

❤

ABOUT BLOOD PRESSURE E-10 — E-12 BLOOD PRESSURE RECORD E-13

CONTACT INFORMATION E-16

TROUBLESHOOTING E-14 SPECIFICATIONS E-15

LifeSource Health Line (Toll-Free)1-888-726-9966
Page 4 of the LifeSource UB-511 user manual — MONITOR COMPONENTS
Page 4 · click to enlarge
Page 4

WHAT DISPLAY SYMBOLS MEAN ?

?

MONITOR COMPONENTS

LifeSource UB-511 — MONITOR COMPONENTS diagram (page 4)
Fig. 7
LifeSource UB-511 — MONITOR COMPONENTS diagram (page 4)
Fig. 8

Appears when measuring is in progress, and flashes when pulse is detected.

Remain still and refrain from talking during monitoring process.

An irregular heartbeat or body movement may have occurred. Refer to page E- 7 for more information on irregular heartbeats.

Replace batteries with two new batteries when the indicator blinks.

The systolic and diastolic measurements are within 10 mmHg of each other.

Try the measurement again. Remain very still during the measurement.

Check cuff to ensure fit and fastening is correct, and measure again.

Check cuff to ensure fit and fastening is correct, and measure again.

Check for correct fit and position of cuff and take another reading.

Measurement is in progress, remain as still as possible.

Display Symbol · Condition/ Error · Recommended Action

Page 5 of the LifeSource UB-511 user manual — BEFORE YOU START
Page 5 · click to enlarge
Page 5

HOW UB-511 WORKS ?

TAKING YOUR BLOOD PRESSURE

LifeSource™Blood Pressure Monitors are easy to use, accurate and display clear digital measurements. Our technology is based on the “oscillometric method”. The term “oscillation” refers to the measure of vibrations caused by the arterial pulse and is a non- invasive method to determine blood pressure. Our monitors examine the pulsatile pressure generated by the arterial wall as it expands and contracts with each heartbeat against the monitor’s cuff. This monitor measures your blood pressure while the cuff is inflating.

Now you are ready to follow these simple steps:

1. Sit comfortably in a chair near a flat surface. 2. With palm facing upward, attach monitor to left wrist and fasten securely. The top edge of the cuff should align with the crease of your wrist. 3. Position your wrist so it is level with your heart, using an arm rest if needed. Positioning of the wrist at heart level is critical for accurate measurement. 4. Press the START button. The average readings from blood pressure measurements stored in memory will appear for a few seconds and the number of measurements stored in memory will flash two times (e.g. A04). The cuff will then begin to inflate. It is normal for the cuff to feel very tight.

BEFORE YOU START

The UB-511 provides accurate readings on wrists with a circumfer- ence between 5.3" and 8.5" (13.5 cm and 21.5 cm). The unit requires two “AAA” (1.5 volt) batteries to operate. To install batteries (or to replace when “Low Battery” symbol appears), proceed as follows:

LifeSource UB-511 — BEFORE YOU START diagram (page 5)
Fig. 9
1. Slide the battery cover as shown to remove from the device. 2. Insert batteries into designated areas ensuring a correct match with positive (+) and negative (-) terminals. 3. Return battery cover by sliding back on to monitoring device.
5. Remain still and refrain from talking or moving during reading.
Page 6 of the LifeSource UB-511 user manual — NUMBER OF MEASUREMENTS
Page 6 · click to enlarge
Page 6

TAKING YOUR BLOOD PRESSURE

WHAT IS AN IRREGULAR HEARTBEAT?

The UB-511 Blood Pressure Monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeat intervals during the blood pres- sure measurement. It is important that you relax, remain still and refrain from talking during measurements. If an irregular heartbeat occurs during a reading, this symbol will appear .

6. As the cuff is inflating, the ❤(heart symbol) will appear to indicate that the measurement is in progress. The monitor measures your blood pressure while the cuff is inflating, so remain still. Once the pulse is detected, the symbol will flash with each pulse beat. 7. When measurement is complete, the systolic and diastolic pressure and pulse rate readings are displayed. The cuff will automatically deflate completely, expelling all remaining air. 8. Press START button once to turn off power. The device has an automatic power-down feature which turns off power auto- matically one minute after measurement is obtained. For the most useful blood pressure history, we recommend that you record the date and time after each measurement. The most accurate history relies not on a single or sporadic readings, but on a consistent monitoring pattern over time.

LifeSource UB-511 — TAKING YOUR BLOOD PRESSURE diagram (page 6)
Fig. 10

The UB-511 provides an average blood pressure reading based on the total measurements stored in memory. When taking a measurement, the average blood pressure reading will appear and the number of measurements stored in memory will flash two times before the cuff begins to inflate. The average blood pressure reading will also appear briefly when you recall the measurements stored in memory.

NUMBER OF MEASUREMENTS

STORED IN MEMORY

Page 7 of the LifeSource UB-511 user manual — E-9
Page 7 · click to enlarge
Page 7

ABOUT MEMORY

ABOUT PRESSURE INDICATOR

The UB-511 automatically stores up to 30 blood pressure and pulse measurements in its memory. Measurements stored in mem- ory are assigned an index number in the order of the newest to the oldest. The oldest reading displays as "n01". To retrieve readings, follow these simple steps:

The Pressure Indicator is located on the left side of the display screen to tell you when the blood monitor is inflating the cuff. The indicator consists of a scale with six levels and moves up during inflation.

1. When the display screen is blank, press and hold the START button. While holding down the START button, you will see the average reading displayed first. You will then see the memory index number (e.g. n03) of the most recent reading followed by the measurement. Release the START button when you see the memory index number. 2. The display will shut off automatically a few seconds after all of the readings are displayed. To turn off the monitor at any time, press the START button. 3. The display will shut off automatically a few seconds after the readings are displayed.

To clear the measurement history from memory, remove the bat- teries from the unit and then place the batteries back into the bat- tery holder.

In Canada (Toll-Free)1-800-461-0991

E-9

Show 6 more labels / short text on this page
Inflation in · Inflation/Measurement · Measurement · Progress · Complete · Displayed
Page 8 of the LifeSource UB-511 user manual — ABOUT MEMORY
Page 8 · click to enlarge
Page 8
LifeSource UB-511 — ABOUT MEMORY diagram (page 8)
Fig. 11
LifeSource UB-511 — ABOUT MEMORY diagram (page 8)
Fig. 12

What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg).

Assessing High Blood Pressure The following standards for assessing high blood pressure (with- out regard to age) have been established as a guideline.

LifeSource UB-511 — ABOUT MEMORY diagram (page 8)
Fig. 13
BP Classification Systolic (mmHg) Diastolic (mmHg) Normal<120 and <80 Prehypertension120-139 or 80-89 Stage 1 Hypertension140-159 or 90-99 Stage 2 Hypertension≥160 or ≥100

What Affects Blood Pressure? Blood pressure is affected by many factors: age, weight, time of day, activity level, climate, altitude and season. Certain activities can significantly alter blood pressure. Walking can raise systolic pres- sure by 12 mmHg and diastolic pressure by 5.5 mmHg. Sleeping can decrease systolic blood pressure by as much as 10 mmHg. Taking your blood pressure repeatedly without waiting an interval of 5 to 10 minutes between readings, or without raising your arm to allow blood to flow back to the heart, can also affect it. In addition to these factors, beverages containing caffeine or alco- hol, certain medications, emotional stress and even tight-fitting clothes can make a difference in the readings.

SOURCE: The Seventh Report of the Joint National Committee on Prevention, Evaluation and Treatment of High Blood Pressure. National Heart, Lung and Blood Institute - May 2003.

What Is Hypertension? Hypertension (high blood pressure) is the diagnosis given when readings consistently rise above normal. It is well known that hypertension can lead to stroke, heart attack or other illness if left untreated. Referred to as a “silent killer” because it does not always produce symptoms that alert you to the problem, hyperten- sion is treatable when diagnosed early. Those who fall within the Prehypertensive range are more likely to develop hypertension in the future.

What Causes Variations In Blood Pressure? An individual’s blood pressure varies greatly from day to day and season to season. In hypersensitive individuals, these variations are even more pronounced. Normally, blood pressure rises during work or play and falls to its lowest levels during sleep.

Can Hypertension Be Controlled? In many individuals, hypertension can be controlled by altering lifestyle and minimizing stress, and by appropriate medication pre- scribed and monitored by your doctor. The American Heart Association recommends the following lifestyle suggestions to pre- vent or control hypertension:

LifeSource UB-511 — ABOUT MEMORY diagram (page 8)
Fig. 14

Don’t smoke. Have regular physical Reduce salt and fat intake. checkups. Maintain proper weight. Monitor your blood Exercise routinely. pressure at periodic intervals.

Page 9 of the LifeSource UB-511 user manual — ABOUT MEMORY
Page 9 · click to enlarge
Page 9
LifeSource UB-511 — ABOUT MEMORY diagram (page 9)
Fig. 15
LifeSource UB-511 — ABOUT MEMORY diagram (page 9)
Fig. 16

Why Measure Blood Pressure at Home? It is now well known that, for many individuals, blood pressure readings taken in a doctor’s office or hospital setting might be ele- vated as a result of apprehension and anxiety. This response is commonly called “white coat hypertension.” One way to deter- mine whether this is the case for you is to take your home moni- tor to the doctor’s office and, before the doctor or nurse takes your pressure, do it yourself on your home monitor and compare it to your record of home readings. In any case, self-measurement at home supplements your doctor’s readings and provides a more accurate, complete blood pressure history. In addition, clinical studies have shown that the detection and treatment of hypertension is improved when patients both consult their physicians and monitor their own blood pressure at home.

B L O O D P R E S S U R E R E C O R D

DATE AM SYS/DIA PULSE PM SYS/DIA PULSE 1/14 9:30 132/98 P 69 6:30 128/87 P 63 E X A M P L E

Keys to Successful Monitoring: Blood pressure fluctuates throughout the day. We recommend that you are consistent in your daily measurement routine:

  • Measure at the same time every day.
  • Sit in the same chair/position.
  • Relax for 5 minutes before measurement.
  • Sit still during measurement – no talking, eating or sudden movements.
  • Record your measurement in a logbook.

How Do I Record My Blood Pressure? Blood pressure readings are typically recorded with the systolic pressure written first, followed by a slash mark and the diastolic pressure. For example, 120 mmHg systolic and 80 mmHg diastolic measurements are written as 120/80. Pulse is simply written with the letter “P” followed by the pulse rate—P 72, for example. Please see Page E-13 for the blood pressure record, or visit www.LifeSourceOnline.com for the BP traking diary E-12 LifeSource Health Line (Toll-Free): 1-888-726-9966

❤

Page 10 of the LifeSource UB-511 user manual — E-15
Page 10 · click to enlarge
Page 10

SPECIFICATIONS

TAKING YOUR BLOOD PRESSURE TROUBLESHOOTING

ProblemProbable causeCorrective action Display is blank, even when the power is turned on.Batteries are drained.Replace with new batteries. Battery terminals are not in the correct position.Place the battery with negative and positive terminals matching those indicated in the battery compartment. The device will not measure. Readings are too high or too low.The cuff is not fastened properly.Fasten the cuff correctly. You moved your arm or body during the measurement.Make sure you remain very still and quiet during the measurement. The position of your wrist is not correct.Position your wrist so it is level with your heart, using an arm rest if needed. OtherOtherThe blood pressure reading is different from that measured at a clinic or doctor’s office.See Pg E-12 “Why Measure Blood Pressure at Home?” Remove the batteries. Place back in correctly, and try the measurement again.

Model UB-511 Type Oscillometric Display Digital, 10/7-mm character height,

Pressure/Pulse displayed simultaneously Memory 30 readings Measurement range Pressure: 20 mmHg to 280 mmHg

Pulse: 40 pulses to 199 pulses/minute Accuracy Pressure: +3 mmHg or 2%, whichever

is greater, Pulse: +5% Pressurization Automatic, using micropump Depressurization Constant air release-valve system Power source 2 type AAA (1.5 volt) alkaline batteries

(included) Battery life Approximately 400 measurements Operating environment 50ºF to 104ºF (10ºC to 40ºC)

Less than 95% relative humidity Storage environment 14ºF to 140ºF (-10ºC to 60ºC)

Less than 95% relative humidity Wrist Circumference Range 5.3 – 8.5”(13.5 – 21.5 cm), Dimensions Depth: 0.8” (21 mm), Width: 2.5”

(63 mm), Height: 2.2” (56 mm), Dimensions with case Length: 4.0” (102 mm), Width: 3.0”

(76 mm), Height: 3.3” (83 mm), approximately Weight 2.9 oz. (82 g) without batteries

Blood pressure measurements determined by the UB-511 are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method within the limits prescribed by the American National Standards Institute for electronic or automated sphygmomanometers.

E-14 LifeSource Health Line (Toll-Free): 1-888-726-9966 In Canada (Toll-Free): 1-800-461-0991

E-15

Page 11 of the LifeSource UB-511 user manual — ?
Page 11 · click to enlarge
Page 11

TAKING YOUR BLOOD PRESSURE CONTACT INFORMATION

IMPORTANT!

If You Need Assistance with the Set-Up or Operation

Our products are designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and treatment options. The product line includes:

We Can Help!

Please call us FIRST before contacting your retailer at

Aneroid Blood Pressure Kits Blood Pressure Cuffs Digital Blood Pressure Monitors Digital Thermometers Heart Rate Monitors Personal Health Scales Stethoscopes Nebulizers

LifeSource Health Line

1-888-726-9966 - Toll Free

1-800-461-0991 - In Canada

This LifeSource product is covered by a Lifetime Warranty. See warranty card for details.

A specially trained representative will assist you

For more information regarding use, care or servicing of your Blood Pressure Monitor, contact:

A&D Medical A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 LifeSource Health Line (Toll-Free): 1-888-726-9966 www.LifeSourceOnline.com

A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www.LifeSourceOnline.com

For Canada Residents, please contact: Auto Control Medical 6695 Millcreek Drive, Unit 5 Mississauga, Ontario L5N 5R8 Canada Auto Control (Toll-Free): 1-800-461-0991 www.autocontrol.com

LifeSource is a trademark of A&D Medical. ©2004 A&D Medical. All rights reserved. Specifications subject to change without notice.

I-MAN:511 Printed in China 11/04

?

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Display is blank, even when the power is turned on.Batteries are drained.Replace with new batteries. p.10
Display is blank, even when the power is turned on.Battery terminals are not in the correct position.Place the battery with negative and positive ter- minals matching those indicated in the battery compartment. p.10
The device will not measure. Readings are too high or too low.The cuff is not fas- tened properly.Fasten the cuff correctly. p.10
The device will not measure. Readings are too high or too low.You moved your arm or body during the measurement.Make sure you remain very still and quiet during the measurement. p.10
The device will not measure. Readings are too high or too low.The position of your wrist is not correct.Position your wrist so it is level with your heart, using an arm rest if needed. p.10
OtherThe blood pressure reading is different from that measured at a clinic or doctor’s office.See Pg E-12 “Why Measure Blood Pressure at Home?” p.10
OtherRemove the batteries. Place back in correctly, and try the measurement again. p.10
Other p.10

Ask about the LifeSource UB-511

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LifeSource UB-511

Be the first to ask — other owners or our team will answer.

Original document

LifeSource UB-511 manual PDF

11 pages·577 KB·Blood Pressure Monitor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…