EN
Omron logo
Official user manual

Omron Blood Pressure Monitor (M4-I)

8 pages·214 KB·Blood Pressure Monitor·PDF·ENDEFRITNLJA
Omron Blood Pressure Monitor (M4-I)
Table of Contents 28 sections M4-I · Instruction manual · Mode d’emploi · Page 41 The World Hypertension League · … ShowHide
Page 1 of the Omron Blood Pressure Monitor (M4-I) user manual — Fully automatic blood pressure monitor
Page 1 · click to enlarge
Page 1

M4-I

Instruction manual

Mode d’emploi

Page 41 The World Hypertension League

Page 2

Pagina 54 Gebruiksaanwijzing

Istruzioni per l’uso

Pagina 15

Gebrauchsanweisung

Instrucciones de uso

Seite 28

Página 67

SYS

M4-I

DIA

EU representative / EU Vertreter Représentant UE / Rappresentante UE Representante UE / EU Vertegenwoordiger

START

OMRON Healthcare Europe BV Kruisweg 577 NL-2132 NA Hoofddorp

Fully automatic blood pressure monitor

Show 4 more labels / short text on this page
mmHg · mmHg · PULSE/min · M4-I Int-5-1
Page 3 of the Omron Blood Pressure Monitor (M4-I) user manual — START
Page 3 · click to enlarge
Page 3

Your blood pressure monitor: the benefits

OMRON M4-I is a compact, fully automatic blood pressure monitor. Monitor, operating on the oscillometric principle. It measures your blood pres- sure and pulse simply and quickly. It contains an intelligent “fuzzy logic” system for controlled inflation, known as “Intelli-sense”. This is an advanced method of oscillo- metric measurement. and does not require pressure pre-setting or re-inflation. OMRON is the world lea- ding manufacturer of blood pressure monitors with the goal to always fulfill the need for reliable regular moni- toring.

Measuring your blood pressure

– Preparing the unit

Open the battery compartment and insert 4 x 1.5v batteries (supplied). Ensure polarity (+/-) of the bat- teries is correct.

Insert air tube to air jack (on the left side of the device). The cuff must be airless.

— Switching on the unit

When you press the ( ) button all the symbols on the display light up for approximately two seconds in order to check the display.

M4-I

SYS

START

Then all the symbols disappear and the air release symbol ( ) begins to flash.

Air Plug (connects to the air jack)

When preparations for measurement are complete the ( ) symbol appears in the display to indicate that the monitor is ready to take a blood pressure measurement.

SYS

M4-I

DIA

Systolic Blood Pressure Display

START

Diastolic Blood Pressure/ Pulse Display

START ( ) button

Show 15 more labels / short text on this page
Cuff · Air Jack · Green area · Air Tube · mmHg · DIA mmHg · PULSE/min · LCD Display · mmHg · Air Jack · mmHg · PULSE/min · Battery Compartment · ON/OFF (O/I) button · Memory button
Page 4 of the Omron Blood Pressure Monitor (M4-I) user manual — S T A R T
Page 4 · click to enlarge
Page 4

š The measurement starts When the target inflation value is reached, the air is auto- matically released. The value in the display counts down- wards.

˜ Fitting the cuff

1. 2 cm

Wrap the cuff around your bare left arm so that the green colored band (indicating the centre of the blad- der) is positioned 1 – 2 cm above your elbow joint on the inside of your arm (see picture).

As soon as the monitor detects your pulse the ( ) sym- bol begins to flash.

When the monitor no longer detects your pulse whilst the cuff pressure is dropping, your systolic and diastolic blood pressures (upper and lower values) will be displayed.

The deflation symbol ( ) will now flash to indicate the end of the measurement.

Close the cuff with the fabric fastener. The green area of the cuff must cover the brachial artery.

When all the air has been released the ( ) symbol appears on the display and your blood pressure and pulse will be displayed on the screen for 5 minutes.

The standard-sized cuff is designed for an arm circumference of 22 – 32 cm. To ensure accurate readings on arms with a circumference greater than 32 cm a large cuff will be required. (large cuff code: CL)

In some rare cases there are people where this measuring method does not work due to physical structure. In such cases OMRON recommends you to consult a doctor. › Successive readings Please leave an interval of at least 2 – 3 minutes should be made in between two successive readings, otherwise the blood flow of the arm could be constricted, which would distort the results of the reading.

Lay your arm on a table or support (e.g. a cushion) with the palm of your hand facing upwards so that the cuff is approximately at heart level. In this way you ensure that the blood pressure measurement ob- tained is neither artificially high (measurement below heart level) nor low (measurement above heart level).

Switch off the device by pressing the ON/OFF ( ) button. The device switches off automatically after approximately 5 minutes.

™ Inflating the cuff

In order to obtain meaningful readings, you should mea- sure your blood pressure regularly at the same time of day, ideally every morning and evening. œ How to use the memory function This monitor has a memory capable of storing fourteen sets of readings. Every time you complete the measurement, the monitor automatically stores blood pressure and pulse rate values.

The OMRON M4-I is a blood pressure monitor with an intelligent system to detect your personal blood pressure.

S T A R T

Using the intelligence of the “Fuzzy Logic” this device determines automatically the correct level of inflation pressure. Just push the START button ( ).

Push the ( ) button to recall stored readings while the Heart Symbol ( ) is displayed.

The cuff must only be inflated when fitted to your arm!

Once the memory holds fourteen sets of readings, the oldest set will be deleted to store a new set.

S T A R T

To delete stored readings, press the ( )button and the Start Button together, then all the readings will be deleted.

Right hand measurement

Page 5 of the Omron Blood Pressure Monitor (M4-I) user manual — E
Page 5 · click to enlarge
Page 5

Hints on taking blood pressure readings

Failure, causes and rectification

  • Before measuring, stretch your back and sit up straight, breathe normally 5-6 times, relax your shoulders, arms and entire body.
  • Slightly bend and support your elbow ( e.g. on a table ).
  • Do not move, talk or touch the device during measurement.
  • Stress influences your blood pressure, so try to relax before taking a measurement.
  • To compare results, measurements must always be taken from the same arm.
  • Do not place the cuff over thick clothes and do not roll up your sleeve if it is too tight.
  • Align the cuff with the height of your heart (breast height). If necessary use a pillow or cushion.
  • Coldness raises your blood pressure. It is recommended to measure at room temperature ( +20°C).
  • Relax before measurement. If necessary go to the bathroom before measurement.
  • Do not measure directly after bathing.
  • If you wish to interrupt measurement prematurely, press the ( ) button. Inflation is stopped and the air is automatically released from the cuff.
  • If you wish to repeat the measurement, follow the same procedure as before starting at step 4 (Inflating the cuff).
  • Blood pressure measurements taken in a moving vehicle may be influenced by vibration.
  • If an error has occurred during measurement E is displayed. Please refer to the next chapter.
  • The monitor should be switched off after measurement to avoid running down the batteries unnecessarily. If you forget to do so, the monitor switches itself off automatically after 5 minutes.

Failure and their possible causes

Incorrect measurement is indicated by

E

1. A correct reading could not be obtained because measurement was disturbed by movement of the body.
1. Repeat the measurement keeping perfectly still. Do not move your arm and do not speak.
2. The cuff is not fitted correctly.
2. Check that the cuff is correctly fitted. Then repeat the measurement.
3. Your clothing has constricted your blood flow.
3. Remove the item of clothing which caused the constriction.
4. There is still air in the cuff when the monitor is switched off.
4. The unit may be defective. Please have it examined and, if necessary, repaired by OMRON Customer Services.

The start button was pressed before the ( ) symbol was displayed

Wait for the ( ) symbol indicating readin- ess before you press the start button.

The blood pressure values displayed are ex- tremely low or high, or they are implausible.

Refer to the instructions and then repeat the measurement.

The display does not light up when the ( ) button is pressed.

1. The batteries are exhausted.
1. Check the batteries and, if necessary, fit 4 new batteries.
2. The +/- poles of the batteries have been reversed.
2. Reinsert the batteries with the +/- poles the right way round.
3. The battery contacts are dirty.
3. Clean the battery contacts with a dry cloth.

The batteries are weak or exhausted.

Fit new batteries.

The cuff pressure does not rise although the pump motor can be heard.

Check that the air tube is properly connec- ted to the monitor. Push the tube connector firmly into the socket.

Err problem with mem. function

Contact Omron Customer Service.

Rectification

Page 6 of the Omron Blood Pressure Monitor (M4-I) user manual — Maintenance and storage
Page 6 · click to enlarge
Page 6

Maintenance and storage

Technical data This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive). This blood pressure monitor is designed according to the European standard EN1060, Non-invasive sphyg- momanometers Part 1: General requirements and Part 3: Supplementary requirements for electrome- chanical blood pressure measuring systems.

  • For cleaning the monitor only use a soft, lightly moistened cloth. Do not use petroleum spirits, thinners or similar solvents!
  • Stains on the cuff can be carefully removed using a moist cloth and soapy water. Do not wash the cuff or make it wet!
ModelOMRON M4-I
DisplayLCD digital display
  • Keep your blood pressure monitor in the storage case to protect it from dust and moisture.

Blood Pressure Pressure: 0 mm Hg to 280 mm Hg Measurement Range: Pulse: 40 – 180/min.

  • Protect your monitor against vibrations and do not leave it in a place where temperatures are extremely low (below -20 °C) or extremely high (above 60 °C) or with high humidity(+ 85%).

Accuracy: Pressure: ±3 mm Hg Pulse: ±5% of reading Memory: 14 measurements Inflation: Fuzzy-Logic controlled by electric pump

DeflationAutomatic pressure release valve
  • Do not use your monitor at very low temperatures (below 10 °C) or very high temperatures (above 40 °C).
Pressure DetectionCapacitive pressure sensor
Measurement MethodOscillometric method
Power Source4 Alkaline batteries 1.5V (Type LR6)
  • Do not fold the cuff or air tube together too tightly and do not crease them.

or AC/DC adapter (optional, 6V = 4W) Battery Life: Capacity of new batteries is approx. 300 measurements

  • Do not carry out repairs of any kind yourself. If a defect occurs, consult the OMRON Customer Service or seek the advice of your surgical appliance stockist or pharmacist.
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 60°C
Humidity30 to 85% RH
  • The well confirmed accuracy of this blood pressure monitor is designed to last a long time.
Storage humidity10 to 95% RH
Console WeightApproximately 450g with batteries
Outer DimensionsApproximately 167.5 mm x 65 mm x 106 mm
  • In order to increase the lifetime of the batteries take them out when you store the device for a longer period than 2 months.

Cuff Dimensions: Approximately 140 mm x 480 mm ( arm circumference 22 – 32 cm ) Accessories: Cuff, Type M (CR17); instruction manual, storage case, battery set

  • Electro-magnetic fields can influence the measurement. Do not use a potable phone near this unit.
  • Disposal of this product and used batteries should be carried out in accordance with the national regulations for the disposal of electronic products.

= Type B

Page 7 of the Omron Blood Pressure Monitor (M4-I) user manual — OMRON spare parts
Page 7 · click to enlarge
Page 7

OMRON spare parts

Some useful information about blood pressure

The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life. It is generally recommended to have the monitor ins- pected every two years to ensure correct functioning and accuracy. Please consult your authorised dealer or the OMRON Customer Service at the address given on the packaging/attached literature.

What is Blood Pressure?

Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the heart’s cycle. The highest pressure in the cycle is called the SYSTOLIC BLOOD PRESSURE; the lowest is the DIASTOLIC BLOOD PRESSURE. Both pres- sure readings, the SYSTOLIC and DIASTOLIC, are necessary to enable a doctor to evaluate the status of a patient’s blood pressure.

OMRON devices are especially designed for regular blood pressure monitoring. OMRON therefore has direct contact with medical specialists and takes advice, on the design and features of its blood pres- sure monitors.

Many factors such as physical activity, anxiety, or the time of day, can influence your blood pressure. Blood pressure is typically low in the morning and increases from afternoon to eve- ning. It is lower in the summer and higher in the winter.

Blood pressure is measured in millimetres of mercury (mmHg) and measurements are written with the systolic pressure before the diastolic e.g. A blood pressure written as 140/90, is referred to as 140 over 90 mmHg.

Spare parts & accessories

Small cuff, Arm circumference 15 – 22 cm Code: CS

Due to high company quality standards, OMRON con- siders the main unit as a non-serviceable part becau- se of the necessity of proper calibration after replace- ment of high-tech components.

The discovery that you have high blood pressure is more often than not a chance finding. People with high blood pressure usually feel well unless the blood pressure has been high for some time, and complications have occurred. Such complications may effect the heart, brain and other important organs. They may bring on ill health and affect your enjoyment of life. It is because of the complications, rather than the high blood pressure itself, that this condition is taken so seriously today.

Normal cuff, Arm circumference 22 – 32 cm Code: CM

High blood pressure is sometimes referred to as raised blood pressure, elevated blood pressure, or hyper- tension. Most people with this condition require regular long-term drug treatment, usually in the form of tablets. Some can lower their blood pressure sufficiently by other means, such as changing diet and life- style. People who have high blood pressure, and who also understand their condition, have an advantage. They are more likely to attend for regular check-ups, to cooperate with advised diets and changes in lifestyle, and to take medicines correctly. This immediately leads to better health. It is hoped that, by a better understan- ding of high blood pressure and how it is treated, you will take an active and informed part in your health care, and so enjoy a better quality of life.

Extra large cuff, Arm circumference 32 – 42 cm Code: CL

Calibration · Mains adapter · High Blood Pressure

Page 8 of the Omron Blood Pressure Monitor (M4-I) user manual — OMRON spare parts
Page 8 · click to enlarge
Page 8

What Causes High Blood Pressure?

Blood pressure is only classed as high if it doesn t go down when you rest. Permanently raised blood pres- sure can be caused by several factors such as hardening of the arteries, smoking or drinking too much alcohol. It can also be caused by cholesterol, a type of fat, building up inside your blood vessels and making them narrower. Being under stress can add to the problem.

High blood pressure is also known to run in families hence if you find you have a high blood pressure it is a good idea to test other closely related members of your family.

(mmHg) Fluctuation within a Day (Example: 35-year-old male)

Arriving at the Company

Discussion on the Telephone

Argument in a Meeting

Leaving the Company Dinner Sleep

6AM 12 6PM 12 Morning Afternoon Evening

Why is it a Good Thing To Measure Blood Pressure at Home?

Having your blood pressure measured by a doctor can cause anxiety which is a cause itself of high blood pressure. As a variety of conditions affect blood pressure, a single measurement may not be sufficient for an accurate diagnosis.

The blood pressure measured first thing in the morning after getting up, before eating and while at rest, is known as the fundamental blood pressure. In practice it is rather difficult to record the fundamental blood pressure, but it is important to get readings in an environment that is as close as possible to this.

Classification of Blood Pressure by the World Heath Organization

The World Health Organization (WHO) and the International Society of Hypertention (ISH) devolloped the Blood Pressure Classification shown in this figure. This classification is based on the blood presure values mea- sured on people in a sitting position in outpatient depart- ments of hospitals.

(mmHg) 80 85 90 100 110

*There is no universally accepted definition of hypotension. However, those having the systolic pressure below 100 mmHg are assumed as hypotensive.

According to the blood pressure classification by the WHO/ISH* (revised in 1999) * International Society of Hypertension

Show 13 more labels / short text on this page
Systolic Blood Pressure · Diastolic Blood Pressure · Get- ting up · Systolic blood pressure · (mmHg) · Severe hypertension · Moderate hypertension · Mild hypertension · Nomal systoric value · Nomal blood pressure · Diastoric blood pressure · Optimal biood · pressure (target value)

Ask about the Omron Blood Pressure Monitor (M4-I)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Omron Blood Pressure Monitor (M4-I)

Be the first to ask — other owners or our team will answer.

Original document

Omron Blood Pressure Monitor (M4-I) manual PDF

8 pages·214 KB·Blood Pressure Monitor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…