A DVANCED /D ELUXE O NE S TEP A UTO -I NFLATIONp.1Blood Pressure Monitorp.1Trilingual Instruction Guide – MODEL UA-767 Plusp.1IMPORTANT INFORMATION ✓p.2TABLE OF CONTENTSp.3E-1p.3MONITOR COMPONENTS ?p.4WHAT DISPLAY SYMBOLS MEAN ?p.4AC ADAPTER JACKp.4AIR SOCKETp.4SYSTOLIC PRESSURE MEMORY BUTTONp.4DIASTOLIC PRESSUREp.4CUFF INFLATION METERp.4PRESSURE RATING INDICATORp.4START BUTTONp.4PULSE RATEp.4AIR CONNECTOR PLUGp.4AIR HOSEp.4CUFFp.4BATTERY COMPARTMENTp.4PULSE DISPLAY ERRORp.4BATTERY COVERp.4OPENp.4? In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991p.4E-3 ?p.4HOW UA-767 PLUS WORKS ?p.5SELECTING THE CORRECT CUFF SIZEp.5BEFORE YOU STARTp.5Cuff Size Indicator On The Cuffp.5INDEXp.5TAKING YOUR BLOOD PRESSUREp.6SYSTOLICp.6DIASTOLICp.6PULSEp.6WHAT IS AN IRREGULAR HEARTBEATp.7ABOUT AVERAGE READINGp.7AVERAGEp.7NUMBER OF MEASUREMENTS STOREDp.7IN MEMORYp.7ABOUT PRESSURE RATING INDICATOR™p.7ABOUT CUFF INFLATION METERp.7ABOUT MEMORYp.8USING THE MONITOR WITH AC ADAPTERp.8ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSUREp.9What Is Blood Pressure?p.9Assessing High Blood Pressure for Adultsp.9What Affects Blood Pressure?p.9What Causes Variations In Blood Pressure?p.9What Is Hypertension?p.10Can Hypertension Be Controlled?p.10Why Measure Blood Pressure at Home?p.10Keys to Successful Monitoring:p.10ABOUT BLOOD PRESSUREp.11TROUBLESHOOTINGp.11Establishing Baseline Measurementsp.11How Do I Record My Blood Pressure?p.11Customer Support Tools Onlinep.11SPECIFICATIONSp.12CONTACT INFORMATIONp.12IMPORTANT!p.13We Can Help!p.13LifeSource Health Linep.131-888-726-9966 - Toll Freep.13Auto Control Medicalp.131-800-461-0991 - In Canadap.13
Page 1 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — Trilingual Instruction Guide – MODEL UA-767 Plus
Page 1 · click to enlarge
Page 1

A DVANCED /D ELUXE O NE S TEP A UTO -I NFLATION

Blood Pressure Monitor

LifeSource Blood Pressure Monitor (UA-767 Plus) — A DVANCED /D ELUXE O NE S TEP A UTO -I NFLATION diagram (page 1)
Fig. 1

Trilingual Instruction Guide – MODEL UA-767 Plus

  • English
  • Français
  • Español
Page 2 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — IMPORTANT INFORMATION ✓
Page 2 · click to enlarge
Page 2

THIS MONITOR IS CLINICALLY VALIDATED ✓ This LifeSource® blood pressure monitor has undergone and passed a Clinical Validation study to determine the performance and accuracy. This monitor is clinically validated according to the British Hypertension Society (BHS) standard. The BHS is the most prestigious international blood pressure organization. The published study was performed by a reviewing committee consisting of physicians and/or nurses. Among blood pressure manufactur- ers, A&D Medical is proud to have the highest number of Clinically Validated monitors with a positive recommendation from professionals that are avail- able to consumers.

IMPORTANT INFORMATION ✓

Please read this important information before using your monitor. ☞ Please remember that only a medical practitioner is qualified to inter- pret your blood pressure measurements. Use of this device should not replace regular medical examinations. ☞ Have your physician review your procedure for using this device. He or she will want to verify blood pressure measurements before pre- scribing or adjusting medications. ☞ Consult your physician if you have any doubt about your readings. Should a mechanical problem occur, contact A&D Medical. ☞ Do not attempt to service, calibrate, or repair this monitor. ☞ Because your UA-767 Plus monitor contains delicate, high-preci- sion parts, avoid exposing it to extremes in temperature or humidity or to direct sunlight, shock and dust. A&D Medical guarantees the accuracy of this monitor only when it is stored and used within the temperature and humidity ranges noted on page E-18. ☞ Clean the monitor and cuff with a dry, soft cloth or a cloth dampened with water and a mild detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean monitor or cuff. ☞ Remove and replace batteries if monitor is not used for more than six months. Alkaline batteries recommended.

The monitor is recommended by the Canadian Hypertension Society.

PRECAUTIONS The UA-767 Plus is designed to be used at home, by those who are eighteen (18) years and older, to monitor blood pressure (systolic and diastolic) and pulse rate.

Page 3 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — Table of Contents
Page 3 · Contents
Contents

Contents

A DVANCED /D ELUXE O NE S TEP A UTO -I NFLATIONp.1Blood Pressure Monitorp.1Trilingual Instruction Guide – MODEL UA-767 Plusp.1IMPORTANT INFORMATION ✓p.2TABLE OF CONTENTSp.3E-1p.3MONITOR COMPONENTS ?p.4WHAT DISPLAY SYMBOLS MEAN ?p.4AC ADAPTER JACKp.4AIR SOCKETp.4SYSTOLIC PRESSURE MEMORY BUTTONp.4DIASTOLIC PRESSUREp.4CUFF INFLATION METERp.4PRESSURE RATING INDICATORp.4START BUTTONp.4PULSE RATEp.4AIR CONNECTOR PLUGp.4AIR HOSEp.4CUFFp.4BATTERY COMPARTMENTp.4PULSE DISPLAY ERRORp.4BATTERY COVERp.4OPENp.4? In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991p.4E-3 ?p.4HOW UA-767 PLUS WORKS ?p.5SELECTING THE CORRECT CUFF SIZEp.5BEFORE YOU STARTp.5Cuff Size Indicator On The Cuffp.5INDEXp.5TAKING YOUR BLOOD PRESSUREp.6SYSTOLICp.6DIASTOLICp.6PULSEp.6WHAT IS AN IRREGULAR HEARTBEATp.7ABOUT AVERAGE READINGp.7AVERAGEp.7NUMBER OF MEASUREMENTS STOREDp.7IN MEMORYp.7ABOUT PRESSURE RATING INDICATOR™p.7ABOUT CUFF INFLATION METERp.7ABOUT MEMORYp.8USING THE MONITOR WITH AC ADAPTERp.8ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSUREp.9What Is Blood Pressure?p.9Assessing High Blood Pressure for Adultsp.9What Affects Blood Pressure?p.9What Causes Variations In Blood Pressure?p.9What Is Hypertension?p.10Can Hypertension Be Controlled?p.10Why Measure Blood Pressure at Home?p.10Keys to Successful Monitoring:p.10ABOUT BLOOD PRESSUREp.11TROUBLESHOOTINGp.11Establishing Baseline Measurementsp.11How Do I Record My Blood Pressure?p.11Customer Support Tools Onlinep.11SPECIFICATIONSp.12CONTACT INFORMATIONp.12IMPORTANT!p.13We Can Help!p.13LifeSource Health Linep.131-888-726-9966 - Toll Freep.13Auto Control Medicalp.131-800-461-0991 - In Canadap.13
Page 4 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — ? In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991
Page 4 · click to enlarge
Page 4

MONITOR COMPONENTS ?

WHAT DISPLAY SYMBOLS MEAN ?

AC ADAPTER JACK

AIR SOCKET

The symbol shown while mea- surement is in progress. It blinks while detecting the pulse.

Measurement is in progress, remain as still as possible.

SYSTOLIC PRESSURE MEMORY BUTTON

An irregular heartbeat or body movement may have occurred. Refer to page E-8 for more infor- mation on irregular heartbeats.

Take measurement again and consult with your physician.

DIASTOLIC PRESSURE

CUFF INFLATION METER

Previous measurement stored in MEMORY.

PRESSURE RATING INDICATOR

START BUTTON

The battery power indicator during measurement. The batteries are low when it blinks.

Replace all batteries with new ones when the symbol blinks. Alkaline batteries recommended.

PULSE RATE

AIR CONNECTOR PLUG

Unstable blood pressure due to excessive body movement.

Try the measurement again. Remain very still during the measurement.

The systolic and diastolic values are within 10 mmHg of each other.

Fasten the cuff correctly, and try the measurement again.

The pressure value did not increase during inflation.

Check for air leaks along the tube and around the air socket.

AIR HOSE

The cuff is not fastened correctly.

Refasten the cuff and retake measurement.

CUFF

BATTERY COMPARTMENT

There is an air leak in the cuff or monitor.

Make sure tube is properly con- nected to cuff and monitor.

The pulse is not detected correctly.

Try the measurement again. Remain very still during the measurement.

PULSE DISPLAY ERROR

+ - + -

Measurement is in progress, remain as still as possible.

+ - + -

BATTERY COVER

OPEN

Refer to the section “About Pressure Rating Indicator” for further explanation.

? In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991

E-3 ?

Show 7 more labels / short text on this page
Display Symbol · Condition/Cause · Recommended Action · Battery Full · Battery Low · Cuff Inflation Meter · Pressure Rating Indicator™
Page 6 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — DIASTOLIC
Page 6 · click to enlarge
Page 6

TAKING YOUR BLOOD PRESSURE

TAKING YOUR BLOOD PRESSURE

Tips for Blood Pressure Monitoring: ☞ Relax for about 5 minutes before measurement. ☞ Do not smoke or ingest caffeine at least 30 minutes prior to measure- ment. ☞ Remove constricting clothing and place cuff on bare arm. ☞ Unless your physician recommends otherwise, use left arm to measure pressure. ☞ Do not talk during measurement. ☞ Do not cross legs and keep you feet flat on floor during measurement.

5. Press the START button. As the cuff pressurizes, measurement will begin and the Cuff Inflation Meter will show on the display screen. It is normal for the cuff to feel very tight.
6. When the inflation is complete, the deflation starts automatically and the ❤ blinks, indicating that the measurement is in progress. Once the pulse is detected, the symbol flashes with each pulse beat.

Now you are ready. Follow these simple steps:

7. When the measurement is complete, the systolic and diastolic pressure readings and pulse rate are displayed.

SYSTOLIC

1. Sit comfortably with your left arm resting on a flat surface so that the center of your upper arm is at the same height as your heart.

The cuff deflates and the monitor automatically shuts off after 60 seconds, or you can turn it off by pressing the START button.

DIASTOLIC

PULSE

2. Lay left arm on the table, palm up and thread cuff end through metal loop, smooth side against arm. Then position the tube off-center toward the inner side of arm in line with the little finger.
8. The reading is then stored into memory. See page E-10 for more details about the memory function.
3. Pull the end of the cuff to tighten it, fold back the extra material, and fasten securely. The cuff should be snug but not too tight. You should be able to insert two fingers between the cuff and your arm.
9. Remove cuff and make a note of your blood pressure and pulse rate on the chart in the back of the manual, indicating date and time of measurement. Additional logbook charts can be downloaded and printed for free at www.LifeSourceOnline.com or in Canada, www.autocontrol.com

We advise that you record the date and time after each measurement because an accurate blood pressure history relies not on single or sporadic readings but on a pattern over time.

4. Confirm that the index points within the proper fit range.

Index and Proper Fit range

Cuff · Tube

Page 7 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — NUMBER OF MEASUREMENTS STORED
Page 7 · click to enlarge
Page 7

WHAT IS AN IRREGULAR HEARTBEAT

ABOUT AVERAGE READING

The UA-767 Plus Blood Pressure Monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. The Irregular Heartbeat symbol will appear in the display window in the event an Irregular Heartbeat has occured during measurement. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeat intervals during the blood pressure measurement. It is important that you relax, remain still and refrain from talking during measurements.

The UA-767 Plus provides an average blood pressure reading based on the total measurements stored in memory. When taking a measurement, the average blood pressure reading will appear and the number of measurements stored in memory will flash several times before the cuff begins to inflate.

AVERAGE

NUMBER OF MEASUREMENTS STORED

IN MEMORY

ABOUT PRESSURE RATING INDICATOR™

ABOUT CUFF INFLATION METER

The Pressure Rating Indicator™ is a feature which provides a snapshot of your blood pressure classifica- tion based on your measurements. This will let you quickly know what your blood pressure readings mean. Each segment of the bar indicator corresponds to the Seventh Report of the Joint National Committee (JNC7) on Prevention, Evaluation and Treatment of High Blood Pressure from the National Heart, Lung and Blood Institute - May 2003. For a more detailed look at this blood pressure classification, please refer to “Assessing High Blood Pressure” on page E-13.

The Cuff Inflation Meter is located on the left side of the display screen to tell you when the blood pressure monitor is inflating and deflating the cuff. The Cuff Inflation Meter moves up during inflation and moves down during deflation.

Inflation in Progress Inflation Complete Deflation/Measurement

:The indicator displays a segment, based on the current measurement, corresponding to the JNC7 Classification.

NOTE: Due to other risk factors (e.g. diabetes, obesity, smoking, etc.) in addition to your blood pressure measurement, the Pressure Rating Indicator is approximate. Please consult with your physician for interpreta- tion and diagnosis of your blood pressure measurements. NOTE: Residents outside of the United States (e.g.. Canada and Mexico) should refer to the WHO Classification Table on page E-13 for assessment of their blood pressure measurement.

LifeSource Health Line (Toll-Free)1-888-726-9966 E-8 In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991 E-9

in Progress

Page 8 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — ABOUT MEMORY
Page 8 · click to enlarge
Page 8

ABOUT MEMORY

USING THE MONITOR WITH AC ADAPTER

This monitor automatically stores up to thirty (30) blood pressure and pulse measurements in memory. Measurements stored in memory are assigned an index number in the order of the newest to the oldest. The oldest reading dis- plays as "n01". The M symbol in the upper left corner of the display screen indicates that you are viewing a previous measurement stored in memory.

The UA-767 Plus has an AC adapter jack to allow you to supply power from an outlet in your home. We recommend you use only the exclusive AC adapter to avoid potential damage to the monitor. Please contact A&D Medical at 1-888-726-9966 (in Canada - 1-800-463-5414) if you would like to purchase the AC adapter.

To retrieve readings, follow these simple steps: 1. When the display screen is blank, press and quickly release the Memory ("M") button. You will see the index number of the most recent reading followed by the measurement. 2. If you want to retrieve other measurements in memory, press and release the Memory button repeatedly until the desired index number is reached (e.g. n04). The measure- ment will then be displayed. 3. The display will shut off automatically a few seconds after the readings are displayed.

Connecting the AC adapter to the monitor: 1. Gently insert the AC adapter plug into a 120V AC outlet. 2. Connect the AC adapter plug into the jack on the right side of the monitor.

Disconnecting the AC adapter from the monitor: 1. Turn the unit off by pressing the START button. 2. Disconnect the plug from the jack of the monitor quickly. 3. Gently remove the AC adapter from the outlet.

To clear the measurement history from memory, press and hold the Memory button for at least five seconds while the display screen is blank. Release the button when you see the M symbol flash and disappear in the upper left hand corner of the display. This indicates that the memory has been cleared.

If there are no measurements stored in memory, you will see two 0s displayed vertically followed by a blinking "A00".

Jack · Plug · AC Adapter

Page 9 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — What Causes Variations In Blood Pressure?
Page 9 · click to enlarge
Page 9

ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE

What Is Blood Pressure?

Assessing High Blood Pressure for Adults

Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg).

The following standards for assessing high blood pressure (without regard to age or gender) have been established as a guideline. Please note that other risk factors (e.g. diabetes, obesity, smoking, etc.) need to be taken into con- sideration and may affect these figures. Consult with your physician for an accurate assessment.

JNC7 Classification Table – for adults within the U.S.

What Affects Blood Pressure?

Blood pressure is affected by many factors: age, weight, time of day, activ- ity level, climate, altitude and season. Certain activities can significantly alter one’s blood pressure. Walking can raise systolic pressure by 12 mmHg and diastolic pressure by 5.5 mmHg. Sleeping can decrease systolic blood pressure by as much as 10 mmHg. Taking your blood pressure repeatedly without waiting an interval of 5 minutes between readings, or without raising your arm to allow blood to flow back to the heart, can also affect it. In addition to these factors, beverages containing caffeine or alcohol, certain medications, emotional stress and even tight-fitting clothes can make a differ- ence in the readings.

BP ClassificationSystolic (mmHg) Diastolic (mmHg) Normalless than 120 and less than 80 Prehypertension120-139 or 80-89 Stage 1 Hypertension140-159 or 90-99 Stage 2 Hypertensiong r e a t e r t h a n 160 or g r e a te r th a n 100 or equal to or equal to
LifeSource Blood Pressure Monitor (UA-767 Plus) — What Affects Blood Pressure? diagram (page 9)
Fig. 2 · What Affects Blood Pressure?

SOURCE: The Seventh Report of the Joint National Committee on Prevention, Evaluation and Treatment of High Blood Pressure for Adults. National Heart, Lung and Blood Institute - May 2003.

WHO Classification Table – for adults outside of the U.S. (e.g. Canada, Mexico)

What Causes Variations In Blood Pressure?

An individual’s blood pressure varies greatly from day to day and season to season. For hypersensitive individuals, these variations are even more pro- nounced. Normally, blood pressure rises during work or play and falls to its lowest levels during sleep.

BP ClassificationSystolic (mmHg) Diastolic (mmHg) Optimalless than 120 and less than 80 Normalless than 130 or less than 85 High-Normal Stage 1 Hypertension130-139 or 85-89 140-159 or 90-99 Stage 2 Hypertension Stage 3 Hypertension160-179 or 100-109 g re a t e r t h a n 180 or g re a t e r t h a n 110 or equal to or equal to
LifeSource Blood Pressure Monitor (UA-767 Plus) — What Causes Variations In Blood Pressure? diagram (page 9)
Fig. 3 · What Causes Variations In Blood Pressure?

SOURCE: Standards to assess high blood pressure, without regard to age or gender, have been established by the World Health Organization (WHO).

Page 10 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — Keys to Successful Monitoring:
Page 10 · click to enlarge
Page 10

ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE

What Is Hypertension?

Answers to Why Your Readings Are Different Between Home and at the Doctor’s Office

Hypertension (high blood pressure) is the diagnosis given when readings consistently rise above normal. It is well known that hypertension can lead to stroke, heart attack or other illness if left untreated. Referred to as a “silent killer” because it does not always produce symptoms that alert you to the problem, hypertension is treatable when diagnosed early.

Why are my readings different between home and at a doctor’s office?

Your blood pressure readings taken in a doctor’s office or hospital setting may be elevated as a result of apprehension and anxiety. This response is known as white coat hypertension.

Can Hypertension Be Controlled?

When I bring my monitor to a doctor’s office, why do I get a different measurement from my monitor to that taken by a doctor or nurse?

In many individuals, hypertension can be controlled by altering lifestyle and- minimizing stress, and by appropriate medication prescribed and monitored by your doctor. The American Heart Association recommends the following lifestyle suggestions to prevent or control hypertension:

The healthcare professional may be using a different sized cuff. The size of the bladder inside the cuff is critical for the accuracy of the measurement. This may give you a different reading. A cuff too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small will pro- duce a reading that is higher than the correct blood pressure. There may also be other factors that can cause the difference in measurements.

Don’t smoke. Have regular physical Reduce salt and fat intake. checkups. Maintain proper weight. Monitor your blood Exercise routinely. pressure at periodic intervals.

Why Measure Blood Pressure at Home?

It is now well known that, for many individuals, blood pressure readings taken in a doctor’s office or hospital setting might be elevated as a result of apprehension and anxiety. This response is commonly called “white coat hypertension.” In any case, self-measurement at home supplements your doctor’s readings and provides a more accurate, complete blood pressure his- tory. In addition, clinical studies have shown that the detection and treatment of hypertension is improved when patients both consult their physicians and monitor their own blood pressure at home.

Keys to Successful Monitoring:

  • Blood pressure fluctuates throughout the day. We recommend that you are consistent in your daily measurement routine:
  • Measure at the same time every day.
  • Sit in the same chair/position.
  • Do not cross legs and keep your feet flat on the floor.
  • Relax for 5 minutes before measurement.
  • Use the correct cuff size to get an accurate reading.
  • Sit still during measurement – no talking, eating or sudden movements.
  • Record your measurement in a logbook.
Page 11 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — Customer Support Tools Online
Page 11 · click to enlarge
Page 11

ABOUT BLOOD PRESSURE

TROUBLESHOOTING

Establishing Baseline Measurements

ProblemProbable causeCorrective action Nothing appears in the display, after I press the START button.Batteries are drained.Replace all batteries with new ones. Alkaline batteries recommended. Battery terminals are not in the correct position.Reinstall the batteries with negative and positive terminals matching those indicated in the battery compartment. The cuff does not inflate.Battery voltage is too low. Low battery symbol blinks. [If the batteries are drained completely, the mark does not appear.]Replace all batteries with new ones. Alkaline batteries recommended. The unit does not measure. Readings are too high or too low.The cuff is not fastened properly.Fasten the cuff correctly. You moved your arm or body during the measurement.Make sure you remain very still and quiet during the measurement. The cuff position is not correct.Sit comfortably and still. Make sure the cuff is at the same level as your heart. You are using the wrong size cuff.See Pg. E-5 "Selecting the Correct Cuff." Taking too many readings on the same arm in a short period of time.Relax five minutes before each measurement. The value is different from that measured at a clinic or doctor’s office.The healthcare professional may be using a different sized cuff.See Pg. E-15 "Answers to Why Your Readings Are Different Between Home and the Doctor’s Office." Your measurements may be elevated by white coat hypertensionSee Pg. E-14 "Why Measure Blood Pressure at Home."

The most important method to get an accurate blood pressure measurement is consistency. To get the most benefit out of your monitor, it is important to establish a “baseline measurement.” This helps build a foundation of measurements that you can use to compare against future readings. To build this baseline measurement, devote two weeks for consistent blood pressure monitoring. This involves doing everything the same way when you measure (e.g. measuring during the same time of day, in the same location, sitting in the same chair, using the same cuff, etc.). Once you establish your baseline measurement, you can start evaluating if your measurement has been affected based on things lifestyle changes or medication treatment.

How Do I Record My Blood Pressure?

Blood pressure readings are typically recorded with the systolic pressure writ- ten first, followed by a slash mark and the diastolic pressure. For example, 120 mmHg systolic and 80 mmHg diastolic measurements are written as 120/80. Pulse is simply written with the letter “P” followed by the pulse rate—P 72, for example. Please see the back of the manual for the blood pressure tracking record.

Customer Support Tools Online

  • Additional tools are available on <a href="http://www.LifeSourceOnline.com" rel="nofollow noopener" target="_blank">www.LifeSourceOnline.com</a> (in Canada - <a href="http://www.autocontrol.com" rel="nofollow noopener" target="_blank">www.autocontrol.com</a>) to help you get the most out of your blood pressure monitoring. These include:
  • Large Print Instruction Manuals
  • Animated Operating Instructions for select models
  • Additional Logbook Sheets
Page 12 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — SPECIFICATIONS
Page 12 · click to enlarge
Page 12

SPECIFICATIONS

CONTACT INFORMATION

Model UA-767P (UA-767 Plus)

Our products are designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and treatment options. Our full product line includes:

Type Oscillometric

Display Digital character height Pressure (16.0 mm)/pulse (10.0 mm) displayed simultaneously

Digital Blood Pressure Monitors Manual Blood Pressure Kits Blood Pressure Cuffs Stethoscopes Personal Health Scales Nebulizers Digital Thermometers

Memory 30 readings

Measurement range Pressure: 20 mmHg to 280 mmHg

Pulse40 pulses to 200 pulses per minute

Accuracy Pressure: +3 mmHg or +2%, whichever is greater Pulse: +5%

Pressurization Automatic, using micropump

This LifeSource blood pressure product is covered by a Lifetime Warranty. See warranty card for details.

Depressurization Automatic constant speed

Power source 4 type “AA” (1.5 volt) alkaline batteries (not included) or 120V AC Adapter

Visit our web site at www.LifeSourceOnline.com

for warranty registration.

Battery life Approximately 6 months with one daily measurement

For more information regarding use, care or servicing of your blood pressure monitor, contact:

Operating environment 50ºF to 104ºF (10ºC to 40ºC) Less than 85% relative humidity

A&D Medical A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 LifeSource Health Line (Toll-Free): 1-888-726-9966 www.LifeSourceOnline.com

Storage environment -4ºF to 140ºF (-20ºC to 60ºC) Less than 95% relative humidity

Dimensions Length: 4.3” (110 mm) Width: 5.8” (147 mm) Height: 2.5” (64 mm)

Weight 10.6 oz. (300 g) without batteries

For Canadian Residents, please contact: Auto Control Medical 6695 Millcreek Drive, Unit 5 Mississauga, Ontario L5N 5R8 Canada Auto Control (Toll-Free): 1-800-461-0991 www.autocontrol.com

Blood pressure measurements determined by the UA-767 Plus are equivalent to those obtained by a trained observer using the cuff/stetho- scope auscultation method within the limits prescribed by the American National Standards Institute for electronic or automated sphygmoma- nometers.

Page 13 of the LifeSource Blood Pressure Monitor (UA-767 Plus) user manual — LifeSource Health Line
Page 13 · click to enlarge
Page 13

IMPORTANT!

If You Need Assistance with the Set-Up or Operation

We Can Help!

Please call us FIRST before contacting your retailer at

LifeSource Health Line

1-888-726-9966 - Toll Free

Auto Control Medical

1-800-461-0991 - In Canada

A specially trained representative will assist you.

A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www.LifeSourceOnline.com

Pressure Rating Indicator is a trademark and LifeSource is a registered trademark of A&D Medical. Pressure Rating Indicator is patent pending. ©2005 A&D Medical. All rights reserved. Specifications subject to change without notice. I-MAN:767P Printed in China 9/05

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Nothing appears in the display, after I press the START button.Batteries are drained.Replace all batteries with new ones. Alkaline batteries recommended. p.11
Nothing appears in the display, after I press the START button.Battery terminals are not in the correct position.Reinstall the batteries with negative and positive termi- nals matching those indicated in the battery compartment. p.11
The cuff does not inflate.Battery voltage is too low. Low battery symbol blinks. [If the batteries are drained completely, the mark does not appear.]Replace all batteries with new ones. Alkaline batteries rec- ommended. p.11
The unit does not measure. Readings are too high or too low.The cuff is not fastened properly.Fasten the cuff correctly. p.11
The unit does not measure. Readings are too high or too low.You moved your arm or body during the measurement.Make sure you remain very still and quiet during the mea- surement. p.11
The unit does not measure. Readings are too high or too low.The cuff position is not correct.Sit comfortably and still. Make sure the cuff is at the same level as your heart. p.11
The unit does not measure. Readings are too high or too low.You are using the wrong size cuff.See Pg. E-5 "Selecting the Correct Cuff." p.11
The unit does not measure. Readings are too high or too low.Taking too many readings on the same arm in a short period of time.Relax five minutes before each measurement. p.11
The value is differ- ent from that measured at a clinic or doctor’s office.The healthcare professional may be using a different sized cuff.See Pg. E-15 "Answers to Why Your Readings Are Different Between Home and the Doctor’s Office." p.11
The value is differ- ent from that measured at a clinic or doctor’s office.Your measurements may be elevated by white coat hypertensionSee Pg. E-14 "Why Measure Blood Pressure at Home." p.11

Ask about the LifeSource Blood Pressure Monitor (UA-767 Plus)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LifeSource Blood Pressure Monitor (UA-767 Plus)

Be the first to ask — other owners or our team will answer.

Original document

LifeSource Blood Pressure Monitor (UA-767 Plus) manual PDF

13 pages·1.2 MB·Blood Pressure Monitor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…