Table of Contents 24 sections T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 · H OME B LOOD P RESSURE K IT I NSTRUCTIONS · IMPORTANT INFORMATION · TABLE OF CONTENTS · … ShowHide
Page 1 of the LifeSource UA-100 user manual — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100
Page 1 · click to enlarge
Page 1
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 1
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 2
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 3
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 4
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 5
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 6
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 7
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 8
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 9
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 10
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 11
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 12
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 13
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 14
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 15
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 16
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 17
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 18
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 19
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 20
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 21
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 22
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 23
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 24
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 25
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 26

T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100

H OME B LOOD P RESSURE K IT I NSTRUCTIONS

LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 27
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 28
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 29
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 30
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 31
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 32
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 33
LifeSource UA-100 — T RILINGUAL I NSTRUCTION G UIDE —MODEL UA-100 diagram (page 1)
Fig. 34
Page 2 of the LifeSource UA-100 user manual — IMPORTANT INFORMATION
Page 2 · click to enlarge
Page 2

older, to monitor blood pressure (systolic and diastolic) and pulse rate.

Please read this important information before using

  • Clean the monitor and cuff with a dry, soft cloth or a cloth dampened with water and a mild detergent. Never use alcohol, benzene,
  • Have your physician review the procedure for using this device. He or she will want to verify blood pressure measurements before
  • Consult your physician if you have any doubt about your readings. Should a mechanical problem occur, contact A&D Medical.

in a doctor’s/nurse’s office, by those who are eighteen (18) years and

  • Please remember that only a medical practitioner is qualified to interpret your blood pressure measurements. Use of this

This Blood Pressure monitor is designed to be used at home or

thinner or other harsh chemicals to clean monitor or cuff.

IMPORTANT INFORMATION

device should not replace regular medical examinations.

LifeSource Health Line (Toll-Free)1-888-726-9966 LifeSource Health Line (Toll-Free): 1-888-726-9966

prescribing or adjusting medications.

cause allergic reactions.

your monitor.

Precautions

Page 4 of the LifeSource UA-100 user manual — HOME BLOOD PRESSURE KIT COMPONENTS
Page 4 · click to enlarge
Page 4
E-3 LifeSource Health Line (Toll-Free)1-888-726-9966
  • Unless your physician recommends otherwise, use left arm to measure pressure.
2. Make sure cuff end has been inserted through the D-Ring.
4. Insert each arm of the Y-Tube into each bottom end of the
  • Remove constricting clothing and place cuff on bare arm.

ASSEMBLY INSTRUCTIONS

TAKING YOUR BLOOD PRESSURE

3. Insert single end of the Y-Tube into stethoscope head.
  • Relax for about 5 to 10 minutes before measurement.
1. Place cuff with arrow pointing towards you.
5. Insert air release valve into left bladder tube.
6. Insert manometer into right bladder tube.

binaurals.

Cuff D-Ring Vinyl Carrying Case

HOME BLOOD PRESSURE KIT COMPONENTS

List of Components:

Show 26 more labels / short text on this page
Vinyl Carrying Case · Stethoscope Head · Cuff · Stethoscope Head · Ear tips · Binaurals · Calibration · Screwdriver · Inflation Bulb · Air Release Valve · Right Bladder Tube · Left Bladder Tube · Cuff D-Ring · Y-Tube · Cuff · Manometer · Left Bladder Tube · Right Bladder Tube · Air Release Valve · Y-Tube · Screwdriver · Inflation Bulb · Calibration · Manometer · Binaurals · Ear tips
Page 5 of the LifeSource UA-100 user manual — TAKING YOUR BLOOD PRESSURE
Page 5 · click to enlarge
Page 5
E-5 LifeSource Health Line (Toll-Free)1-888-726-9966
8. Inflate the cuff by repeatedly squeezing the bulb with your right hand. Listen to the pulse beat while inflating the cuff.
6. Hold the manometer in your left hand and the inflation bulb in your right hand.
9. Watch the gauge. When you can no longer hear the pulse beat, raise the pressure an additional 30 mmHg.
10. After reaching your inflation level, slowly deflate the cuff by opening the air release valve. To open the air release valve, turn

second. The needle on the manometer should drop an average

5. Insert the ear tips of the stethoscope into your ears. Adjust by

it counter-clockwise so that the pressure drops 2-4 mmHg per

may injure yourself or damage the equipment. If you are

uncertain about the proper cuff inflation level, consult

7. Close the air release valve on the bulb by turning the valve

the arm. Do not leave it fully inflated any longer than

TAKING YOUR BLOOD PRESSURE

turning ear tips to fit comfortably in your ears.

of one to two marks every second.

absolutely necessary.

your physician.

clockwise.

Now you are ready. Follow these simple steps:

TAKING YOUR BLOOD PRESSURE

upper arm with the tube facing

between the cuff and your arm.

4. With your palm facing up, place

where the main artery is located.

1. Sit comfortably with your left
2. Lay left arm on the table with

above the bend of the elbow on

arm resting on a flat surface

3. The cuff should be snug but

not too tight. You should be

the stethoscope head one-inch

cuff securely with hook and

the inside of the arm. This is

so that the center of your

palm up. Place the cuff on

downward and toward the

inside of your arm. Fasten

upper arm is at the same

able to insert two fingers

height as your heart.

loop fastener strap.

Page 6 of the LifeSource UA-100 user manual — TAKING YOUR BLOOD PRESSURE
Page 6 · click to enlarge
Page 6
LifeSource UA-100 — ASSEMBLY INSTRUCTIONS diagram (page 6)
Fig. 35
E-7 LifeSource Health Line (Toll-Free)1-888-726-9966

pressure occurs when the heart expands. Blood pressure is measured

nificantly alter one’s blood pressure. Walking can raise systolic pressure

Sleeping can decrease systolic blood pressure by as much as 10 mmHg.

Taking your blood pressure repeatedly without waiting an interval of

Blood pressure is the force exerted by blood against the walls of the

arteries. Systolic pressure occurs when the heart contracts; diastolic

activity level, climate, altitude and season. Certain activities can sig-

Blood pressure is affected by many factors: age, weight, time of day,

5 to 10 minutes between readings, or without raising your arm to allow blood to flow back to the heart, can also affect it.

by 12 mmHg and diastolic pressure by 5.5 mmHg.

2. Have the person extend his or her left arm toward you, palm up.
4. Attach the manometer to the loop on the cuff, so that it is clearly

If possible, have your physician watch your technique to be sure

11. After opening the air release valve, listen carefully for a pulse beat. The moment you hear the first thumping sounds of your

pulse beat, note the reading on the gauge. This is your systolic

person whose blood pressure is to be taken to rest and relax at

1. If you plan on taking someone else’s blood pressure, have the
3. Position the cuff as indicated in the self-taking instructions.
12. When you can no longer hear any sounds, read the gauge. This is your diastolic blood pressure measurement.
13. Remove cuff and make note of your blood pressure on the blood pressure record located on page E-9.

readings were as accurate as possible, wait 10-15

Be sure the arm rests at the same level as the heart.

5. Perform Steps 1-13 in Taking Your Blood Pressure.

TAKING YOUR BLOOD PRESSURE

minutes and repeat the procedure.

least 15 minutes beforehand.

blood pressure measurement.

visible to you.

it is correct.

Two-party method

Page 7 of the LifeSource UA-100 user manual — ABOUT BLOOD PRESSURE
Page 7 · click to enlarge
Page 7
LifeSource UA-100 — ABOUT BLOOD PRESSURE diagram (page 7)
Fig. 36
LifeSource Health Line (Toll-Free)1-888-726-9966 E-8 LifeSource Health Line (Toll-Free): 1-888-726-9966 E-9

or alcohol, certain medications, emotional stress and even tight-fitting

more pronounced. Normally, blood pressure rises during work or play

An individual’s blood pressure varies greatly from day to day and season

Category Systolic (mmHg) Diastolic (mmHg)

to season. For hypersensitive individuals, these variations are even

The following standards for assessing high blood pressure (without

regard to age) have been established by the National Institutes of

In addition to these factors, diet beverages containing caffeine

What Causes Variations In Blood Pressure?

Stage 2 160 – 179 100 – 109

High Normal 130 - 139 85 – 89

Stage 1 140 – 159 90 – 99

Stage 3 ≥180 ≥110

clothes can make a difference in the readings.

Assessing High Blood Pressure

and falls to its lowest levels during sleep.

ABOUT BLOOD PRESSURE

Health JNCVI.

Optimal

Page 8 of the LifeSource UA-100 user manual — MAINTENANCE INSTRUCTIONS
Page 8 · click to enlarge
Page 8

connector end of the manometer. Turn the screw driver in either

A&D Medical warrants, to the first retail purchaser of the Manometer

the Product becomes inaccurate under normal conditions of use. See

2. If the needle on the dial rests within the zero indicator on the

(the Product), free accuracy adjustment for a period of two years if

How to Check your Home Blood Pressure Kit for

1. Detach manometer from bladder tube. Hold manometer in a

direction without going all the way around the dial to get the

5. If the unit cannot be recalibrated using this method, please contact A&D Medical at 1-888-726-9966.
3. If the needle rests outside the zero indicator, it should be
4. To recalibrate, insert the small screwdriver into the hose

CHECKING FOR ACCURACY

face plate, your unit is guaranteed to be accurate.

LifeSource Health Line (Toll-Free)1-888-726-9966 E-10 LifeSource Health Line (Toll-Free): 1-888-726-9966

enclosed warranty card for complete details.

needle back to the zero indicator.

vertical position.

recalibrated.

A&D Medical has checked your blood pressure unit to assure reliability

and accuracy prior to shipment. However, as with any sensitive instru-

ment subject to repeated use, we recommend your blood pressure unit

be checked periodically for proper calibration to ensure accurate blood

With proper care, your Home Blood Pressure Kit will provide many

  • Store all items, including instruction booklet, in the convenient storage case provided.

years of reliable service. To insure a well functioning unit, follow

  • Handle the pressure manometer with care. Do not drop or jar. The needle should indicate zero when cuff is fully deflated.

Basic Care of Your Home Blood Pressure Kit

  • Avoid hitting objects against surface of stethoscope.

MAINTENANCE INSTRUCTIONS

  • Always deflate cuff before storing.

these basic rules:

pressure readings.

Two-Year Calibration Warranty · Accuracy

Page 9 of the LifeSource UA-100 user manual — CONTACT INFORMATION
Page 9 · click to enlarge
Page 9

Our products are designed and manufactured using the latest scientific

Heart Rate Monitors Blood Pressure Cuffs

Digital Blood Pressure Monitors Digital Thermometers

For more information regarding use, care or servicing of your blood

monitoring and treatment options. Our full product line includes:

This LifeSource blood pressure product is covered by a two-

and technological methods, and offer accurate, easy to use, home

(Toll-Free)1-800-463-5414

VISIT OUR WEBSITE AT WWW.LIFESOURCEONLINE.COM

Aneroid Blood Pressure Kits Stethoscopes

206A boul. Brunswick Pointe-Claire, Quebec

www.autocontrol.com

FOR WARRANTY REGISTRATION.

please contact:

year warranty. See warranty card for details.

LifeSource is a trademark of A&D Medical. © 2002 A&D Medical.

Specifications subject to change without notice. All rights reserved.

CONTACT INFORMATION

(Toll-Free)1-888-726-9966

www.LifeSourceOnline.com

pressure monitor, contact:

A&D Engineering, Inc.

1555 McCandless Drive Milpitas, CA 95035

UA-100 printed in Taiwan 02/02.

Show 6 more labels / short text on this page
Auto Control Medical · Canadian residents, · H9R 5P9 Canada · LifeSource Health Line · A&D Medical · A division of
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LifeSource UA-100

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LifeSource UA-100

Be the first to ask — other owners or our team will answer.

Original document

LifeSource UA-100 manual PDF

9 pages·450 KB·Blood Pressure Monitor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…