EN
LifeSource logo
Official user manual

LifeSource UB-328

20 pages·492 KB·Blood Pressure Monitor·PDF·ENDEFRITNLJA
LifeSource UB-328
Table of Contents 32 sections A UTOMATIC W RIST · Blood Pressure Monitor · Trilingual Instruction Guide – MODEL UB-328 · IMPORTANT INFORMATION · … ShowHide
Page 1 of the LifeSource UB-328 user manual — Trilingual Instruction Guide – MODEL UB-328
Page 1 · click to enlarge
Page 1

A UTOMATIC W RIST

Blood Pressure Monitor

LifeSource UB-328 — A UTOMATIC W RIST diagram (page 1)
Fig. 1

Trilingual Instruction Guide – MODEL UB-328

  • English
  • Français
  • Español
Page 2 of the LifeSource UB-328 user manual — IMPORTANT INFORMATION
Page 2 · click to enlarge
Page 2

IMPORTANT INFORMATION

Please read this important information before using your monitor. Please remember that only a medical practitioner is qualified to interpret your blood pressure measurements. Use of this device should not replace regular medical examinations. Have your physician review your procedure for using this device. He or she will want to verify blood pressure measurements before prescribing or adjusting medications. Consult your physician if you have any doubt about your readings. Should a mechanical problem occur, contact A&D Medical. Make sure to use the correct cuff size when measuring your blood pressure. Do not attempt to service, calibrate, or repair this monitor. Because your UB-328 monitor contains delicate, high-precision parts, avoid exposing it to extremes in temperature or humidity or to direct sunlight, shock and dust. A&D Medical guarantees the accuracy of this monitor only when it is stored and used within the temperature and humidity ranges noted on page E-15. Clean the monitor and cuff with a dry, soft cloth or a cloth dampened with water and a mild detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean monitor or cuff. Remove and replace batteries if monitor is not used for more than six months. Alkaline batteries recommended.

PRECAUTIONS The UB-328 is designed to be used at home, by those who are eighteen (18) years and older, to monitor blood pressure (systolic and diastolic) and pulse rate.

Page 3 of the LifeSource UB-328 user manual — IMPORTANT INFORMATION
Page 3 · click to enlarge
Page 3

Fast. Easy. Accurate.

Congratulations on purchasing a state-of-the-art LifeSource® blood pressure monitor—one of the most technologically advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen.

Physicians agree that daily self-monitoring of blood pressure is an important step individuals can take to maintain cardiovascular health and prevent the serious consequences associated with undetected and untreated hypertension.

A&D Medical has been manufacturing high quality healthcare products for over 20 years. We are committed to providing you and your family with monitoring devices that provide the utmost in accuracy and convenience.

LifeSource - Designed for Life.

Page 5 of the LifeSource UB-328 user manual — WHAT DISPLAY SYMBOLS MEAN
Page 5 · click to enlarge
Page 5

?

WHAT DISPLAY SYMBOLS MEAN

Display SymbolCondition/CauseRecommended Action The symbol shown while measurement is in progress. It blinks while detecting the pulse.Measurement is in progress, remain as still as possible. An irregular heartbeat or body movement may have occurred. Refer to page E-7 for more information on irregular heartbeats.Take measurement again and consult with your physician. Previous measurement stored in MEMORY. Battery LowAppears when battery voltage is insufficient for device to function.Replace all batteries with new ones. Alkaline batteries recommended. The systolic and diastolic values are within 10 mmHg of each other.Check cuff to ensure fit and fastening is correct, and measure again. Unstable blood pressure due to excessive body movement. The cuff is not fastened correctly.Try the measurement again. Remain very still during the measurement. Fasten the cuff correctly, and try the measurement again. Pulse Display ErrorThe pulse is not detected correctly.Refasten the cuff and retake measurement.
LifeSource Health Line (Toll-Free)1-888-726-9966
Page 6 of the LifeSource UB-328 user manual — SYSTOLIC PRESSURE
Page 6 · click to enlarge
Page 6

? MONITOR COMPONENTS

MEMORY BUTTON

LifeSource UB-328 — MEMORY BUTTON diagram (page 6)
Fig. 2

SYSTOLIC PRESSURE

DIASTOLIC PRESSURE

PULSE RATE

BATTERY HOLDER COVER

LifeSource UB-328 — SYSTOLIC PRESSURE diagram (page 6)
Fig. 3

In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991

Page 7 of the LifeSource UB-328 user manual — ?!
Page 7 · click to enlarge
Page 7

HOW UB-328 WORKS ?

LifeSource® blood pressure monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the "oscillometric method" – a noninvasive blood pressure determination. The term "oscillation" refers to any measure of vibrations caused by the arterial pulse. Our monitor examines the pulsatile pressure generated by the arterial wall as it expands and contracts against the cuff with each heartbeat.

The cuff is inflated until the artery is fully blocked. The inflation speed is maximized and the pressure level is optimized by the device. The monitor takes measurements while the cuff is both inflating and deflating. This results in a faster measurement providing greater comfort to the user.

LifeSource UB-328 — HOW UB-328 WORKS ? diagram (page 7)
Fig. 4

The UB-328 provides accurate readings on wrists with a circumference between 5.3 and 7.7" (13.5 and 19.5 cm).

The unit requires two "AAA" (1.5 volt) batteries to operate (alkaline batteries recommended). To install batteries (or to replace when "Low Battery" symbol appears), proceed as follows:

1. Slide the battery cover as shown to remove from the device
LifeSource UB-328 — HOW UB-328 WORKS ? diagram (page 7)
Fig. 5
2. Insert batteries into designated areas ensuring a correct match with positive (+) and negative (-) terminals.
3. Return battery cover by sliding back on to monitoring device.

?!

LifeSource Health Line (Toll-Free)1-888-726-9966
Page 8 of the LifeSource UB-328 user manual — TAKING YOUR BLOOD PRESSURE
Page 8 · click to enlarge
Page 8

TAKING YOUR BLOOD PRESSURE

Tips for Blood Pressure Monitoring: Relax for about 5 minutes before measurement. Do not smoke or ingest caffeine at least 30 minutes prior to measurement. Remove constricting clothing and place cuff on bare wrist. Unless your physician recommends otherwise, use left wrist to measure pressure. Do not talk during measurement. Do not cross legs and keep you feet flat on floor during measurement.

Now you are ready. Follow these simple steps:

1. Sit comfortably in a chair near a flat surface.
2. With palm facing upward, attach monitor to left wrist and fasten securely. The top edge of the cuff should align with the crease of your wrist.
3. Position your wrist so it is level with your heart, using an arm rest if needed. Positioning of the wrist at heart level is critical for accurate measurement.
5. Remain still and refrain from talking or moving during reading.

Monitor at · heart level

Page 9 of the LifeSource UB-328 user manual — PULSE
Page 9 · click to enlarge
Page 9

TAKING YOUR BLOOD PRESSURE

6. After the cuff is fully inflated, it will automatically start to deflate and ❤ symbol will appear to indicate that measurement is in progress. Once the pulse is detected, the symbol will flash with each pulse beat.
7. When measurement is complete, the systolic and diastolic pressure and pulse rate readings are displayed. The cuff will automatically deflate completely, expelling all remaining air.

SYSTOLIC

DIASTOLIC

8. Press START button once to turn off power. The device has an automatic power-down feature which turns off power automatically one minute after measurement is obtained.

PULSE

9. Remove monitor and make a note of your blood pressure and pulse rate on the chart in the back of the manual, indicating date and time of measurement. Additional logbook charts can be downloaded and printed for free at www.LifeSourceOnline.com or in Canada, www.autocontrol.com

We advise that you record the date and time after each measurement because an accurate blood pressure history relies not on single or sporadic readings but on a pattern over time.

LifeSource Health Line (Toll-Free)1-888-726-9966
Page 10 of the LifeSource UB-328 user manual — IN MEMORY
Page 10 · click to enlarge
Page 10

WHAT IS AN IRREGULAR HEARTBEAT

The UB-328 Blood Pressure Monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. The Irregular Heartbeat symbol will appear in the display window in the event an Irregular Heartbeat has occured during measurement. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeat intervals during the blood pressure measurement. It is important that you relax, remain still and refrain from talking during measurements.

LifeSource UB-328 — WHAT IS AN IRREGULAR HEARTBEAT diagram (page 10)
Fig. 6

The UB-328 provides an average blood pressure reading based on the total measurements stored in memory. Press and release the Memory button to see the average blood pressure reading. Average pulse rate readings are not provided by this monitor. The average blood pressure reading will appear and the number of measurements stored in memory appear for approximately five seconds.

IN MEMORY

Page 11 of the LifeSource UB-328 user manual — ABOUT MEMORY
Page 11 · click to enlarge
Page 11

ABOUT MEMORY

The UB-328 automatically stores up to 30 blood pressure and pulse measurements in its memory. Measurements stored in memory are assigned an index number in the order of the newest to the oldest. The oldest reading displays as "n01". The M symbol in lower left corner of the display screen indicates that you are viewing a previous measurement stored in memory.

To retrieve readings, follow these simple steps: 1. When the display screen is blank, press and release the Memory button. You will see the average blood pressure reading displayed. Press and release the Memory button again. You will see the index number of the most recent reading followed by the measurement.

2. If you want to retrieve other measurements in memory, press and release the Memory button repeatedly until the desired index number is reached (e.g. n03). The measurement will then be displayed.
3. The display will shut off automatically a few seconds after the readings are displayed.

To clear the measurement history from memory, remove the batteries from the unit and then place the batteries back into the battery holder.

E-8 LifeSource Health Line (Toll-Free)1-888-726-9966
Page 12 of the LifeSource UB-328 user manual — ABOUT BLOOD PRESSURE
Page 12 · click to enlarge
Page 12

ABOUT BLOOD PRESSURE

What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg).

What Affects Blood Pressure? Blood pressure is affected by many factors: age, weight, time of day, activity level, climate, altitude and season. Certain activities can significantly alter one’s blood pressure. Walking can raise systolic pressure by 12 mmHg and diastolic pressure by 5.5 mmHg. Sleeping can decrease systolic blood pressure by as much as 10 mmHg. Taking your blood pressure repeatedly without waiting an interval of 5 minutes between readings, or without raising your arm to allow blood to flow back to the heart, can also affect it.

In addition to these factors, beverages containing caffeine or alcohol, certain medications, emotional stress and even tight-fitting clothes can make a difference in the readings.

What Causes Variations In Blood Pressure? An individual’s blood pressure varies greatly from day to day and season to season. For hypersensitive individuals, these variations are even more pronounced. Normally, blood pressure rises during work or play and falls to its lowest levels during sleep.

LifeSource UB-328 — ABOUT BLOOD PRESSURE diagram (page 12)
Fig. 7
Page 13 of the LifeSource UB-328 user manual — ABOUT BLOOD PRESSURE
Page 13 · click to enlarge
Page 13

ABOUT BLOOD PRESSURE

Assessing High Blood Pressure for Adults The following standards for assessing high blood pressure (without regard to age or gender) have been established as a guideline. Please note that other risk factors (e.g. diabetes, obesity, smoking, etc.) need to be taken into consideration and may affect these figures. Consult with your physician for an accurate assessment.

JNC7 Classification Table – for adults within the U.S

BP Classification Systolic (mmHg) Diastolic (mmHg)

Normal less than 120 and less than 80

Prehypertension 120-139 or 80-89

Stage 1 Hypertension 140-159 or 90-99

greater than or equal to

greater than or equal to

Stage 2 Hypertension 160 or 100

SOURCE: The Seventh Report of the Joint National Committee on Prevention, Evaluation and Treatment of High Blood Pressure for Adults. National Heart, Lung and Blood Institute - May 2003.

WHO Classification Table – for adults outside of the U.S. (e.g. Canada, Mexico)

BP Classification Systolic (mmHg) Diastolic (mmHg)

Optimal less than 120 and less than 80

Normal less than 130 or less than 85

High-Normal 130-139 or 85-89

Stage 1 Hypertension 140-159 or 90-99

Stage 2 Hypertension 160-179 or 100-109

greater than or equal to greater than or equal to

Stage 3 Hypertension 180 or 110

SOURCE: Standards to assess high blood pressure, without regard to age or gender, have been established by the World Health Organization (WHO).

E-10 LifeSource Health Line (Toll-Free)1-888-726-9966
Page 14 of the LifeSource UB-328 user manual — ABOUT BLOOD PRESSURE
Page 14 · click to enlarge
Page 14

ABOUT BLOOD PRESSURE

What Is Hypertension? Hypertension (high blood pressure) is the diagnosis given when readings consis- tently rise above normal. It is well known that hypertension can lead to stroke, heart attack or other illness if left untreated. Referred to as a “silent killer” because it does not always produce symptoms that alert you to the problem, hypertension is treatable when diagnosed early.

Can Hypertension Be Controlled? In many individuals, hypertension can be controlled by altering lifestyle and minimizing stress, and by appropriate medication prescribed and monitored by your doctor. The American Heart Association recommends the following lifestyle suggestions to prevent or control hypertension:

Don’t smoke. Have regular Reduce salt and fat intake. physical checkups. Maintain proper weight. Monitor your blood Exercise routinely. pressure at periodic intervals.

Why Measure Blood Pressure at Home? It is now well known that, for many individuals, blood pressure readings taken in a doctor’s office or hospital setting might be elevated as a result of apprehension and anxiety. This response is commonly called “white coat hypertension.”

In any case, self-measurement at home supplements your doctor’s readings and provides a more accurate, complete blood pressure history. In addition, clinical studies have shown that the detection and treatment of hypertension is improved when patients both consult their physicians and monitor their own blood pressure at home.

Page 15 of the LifeSource UB-328 user manual — ABOUT BLOOD PRESSURE
Page 15 · click to enlarge
Page 15

ABOUT BLOOD PRESSURE

Answers to Why Your Readings are Different Between Home and at the Doctor’s Office

Why are my readings different between home and at a doctor’s office?

Your blood pressure readings taken in a doctor’s office or hospital setting may be elevated as a result of apprehension and anxiety. This response is known as white coat hypertension.

When I bring my monitor to a doctor’s office, why do I get a different measurement from my monitor to that taken by a doctor or nurse?

The healthcare professional may be using a different sized cuff. The size of the bladder inside the cuff is critical for the accuracy of the measurement. This may give you a different reading. A cuff too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small will produce a reading that is higher than the correct blood pressure. There may also be other factors that can cause the difference in measurements.

Keys to Successful Monitoring: Blood pressure fluctuates throughout the day. We recommend that you are consistent in your daily measurement routine:

  • Measure at the same time every day.
  • Sit in the same chair/position.
  • Do not cross legs and keep your feet flat on the floor.
  • Relax for 5 minutes before measurement.
  • Use the correct cuff size to get an accurate reading.
  • Sit still during measurement – no talking, eating or sudden movements.
  • Record your measurement in a logbook.
E-12 LifeSource Health Line (Toll-Free)1-888-726-9966
Page 16 of the LifeSource UB-328 user manual — ABOUT BLOOD PRESSURE
Page 16 · click to enlarge
Page 16

ABOUT BLOOD PRESSURE

Establishing Baseline Measurements The most important method to get an accurate blood pressure measurement is consistency. To get the most benefit out of your monitor, it is important to establish a “baseline measurement.” This helps build a foundation of measurements that you can use to compare against future readings. To build this baseline measurement, devote two weeks for consistent blood pressure monitoring. This involves doing everything the same way when you measure (e.g. measuring during the same time of day, in the same location, sitting in the same chair, using the same cuff, etc.). Once you establish your baseline measurement, you can start evaluating if your measurement has been affected based on things lifestyle changes or medication treatment.

How Do I Record My Blood Pressure? Blood pressure readings are typically recorded with the systolic pressure written first, followed by a slash mark and the diastolic pressure. For example, 120 mmHg systolic and 80 mmHg diastolic measurements are written as 120/80. Pulse is simply written with the letter “P” followed by the pulse rate—P 72, for example. Please see the back of the manual for the blood pressure tracking record.

Customer Support Tools Online Additional tools are available on www.LifeSourceOnline.com (in Canada - www.autocontrol.com) to help you get the most out of your blood pressure monitoring. These include:

  • Large Print Instruction Manuals
  • Animated Operating Instructions for select models
  • Additional Logbook Sheets
Page 17 of the LifeSource UB-328 user manual — TROUBLESHOOTING
Page 17 · click to enlarge
Page 17

TROUBLESHOOTING

Nothing appears in the display, even when the power is turned on.

Batteries are drained.

Replace all batteries with new ones. Alkaline batteries recommended.

Battery terminals are not in the correct position.

Reinstall the batteries with negative and positive terminals matching those indicated in the battery compartment.

The cuff does not inflate.

Battery voltage is too low. Low battery symbol blinks. [If the batteries are drained completely, the mark does not appear.]

Replace all batteries with new ones. Alkaline batteries recommended.

The unit does not measure. Readings are too high or too low.

The cuff is not fastened properly.

Fasten the cuff correctly.

You moved your arm or body during the measurement.

Make sure you remain very still and quiet during the measurement.

The cuff position is not correct.

Sit comfortably and still. Make sure the cuff is at the same level as your heart.

Taking too many readings on the same arm in a short period of time.

Relax five minutes before each measurement.

The value is different from that measured at a clinic or doctor’s office.

The healthcare profes- sional may be using a different sized cuff.

See Pg. E-12 "Answers to Why Your Readings Are Different Between Home and the Doctor’s Office."

Your measurements may be elevated by white coat hypertension.

See Pg. E-11 "Why Measure Blood Pressure at Home."

LifeSource Health Line (Toll-Free)1-888-726-9966

Problem · Probable cause · Corrective action

Page 18 of the LifeSource UB-328 user manual — SPECIFICATIONS
Page 18 · click to enlarge
Page 18

SPECIFICATIONS

Model UB-328

Type Oscillometric

Display Digital, 10/7-mm character height,

Memory 30 readings

Measurement range Pressure: 20 mmHg to 280 mmHg

Pulse40 pulses to 200 pulses/minute

Accuracy Pressure: +3 mmHg or +2%,

whichever is greater, Pulse+5%

Pressurization Automatic, using micropump

Depressurization Constant air release-valve system

Power source 2 type AAA (1.5 volt) alkaline

Battery life Approximately 400 measurements

Operating environment 50ºF to 104ºF (10ºC to 40ºC)

Less than 95% relative humidity

Storage environment 14ºF to 140ºF (-10ºC to 60ºC)

Less than 95% relative humidity

Wrist Circumference Range 5.3 – 7.7" (13.5 – 19.5 cm),

Dimensions Length: 3.1" (79 mm), Width: 2.9"

(73 mm), Height2.3" (58 mm),

Dimensions with case Length: 4.0" (102 mm), Width: 3.0"

(76 mm), Height3.3" (83 mm), approximately

Weight 4.2 oz. (120 g) without batteries

Blood pressure measurements determined by the UB-328 are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method within the limits prescribed by the American National Standards Institute for electronic or automated sphygmomanometers.

Pressure/pulse displayed simultaneously · batteries (not included)

Page 19 of the LifeSource UB-328 user manual — Visit our web site at www.LifeSourceOnline.com
Page 19 · click to enlarge
Page 19

CONTACT INFORMATION

Our products are designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and treatment options. Our full product line includes:

Digital Blood Pressure Monitors Manual Blood Pressure Kits Blood Pressure Cuffs Stethoscopes Personal Health Scales Nebulizers Digital Thermometers

This LifeSource blood pressure product is covered by a

Lifetime Warranty. See warranty card for details.

Visit our web site at www.LifeSourceOnline.com

for warranty registration.

For more information regarding use, care or servicing of your blood pressure monitor, contact:

A&D Medical A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 LifeSource Health Line (Toll-Free): 1-888-726-9966 www.LifeSourceOnline.com

For Canadian Residents, please contact: Auto Control Medical 6695 Millcreek Drive, Unit 5 Mississauga, Ontario L5N 5R8 Canada Auto Control (Toll-Free): 1-800-461-0991 www.autocontrol.com

E-16 LifeSource Health Line (Toll-Free)1-888-726-9966
Page 20 of the LifeSource UB-328 user manual — LifeSource Health Line
Page 20 · click to enlarge
Page 20

IMPORTANT!

If You Need Assistance with the Set-Up or Operation

We Can Help!

Please call us FIRST before contacting your retailer at

LifeSource Health Line

1-888-726-9966 - Toll Free

Auto Control Medical

1-800-461-0991 - In Canada

A specially trained representative will assist you.

A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www.LifeSourceOnline.com

Pressure Rating Indicator is a trademark and LifeSource is a registered trademark of A&D Medical. Pressure Rating Indicator is patent pending. ©2005 A&D Medical. All rights reserved. Specifications subject to change without notice. I-MAN:328 Printed in China 5/05

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Nothing appears in the display, even when the power is turned on.Batteries are drained.Replace all batteries with new ones. Alkaline batteries recommended. p.17
Nothing appears in the display, even when the power is turned on.Battery terminals are not in the correct position.Reinstall the batteries with negative and positive terminals matching those indicated in the battery compartment. p.17
The cuff does not inflate.Battery voltage is too low. Low battery symbol blinks. [If the batteries are drained completely, the mark does not appear.]Replace all batteries with new ones. Alkaline batteries recommended. p.17
The unit does not measure. Readings are too high or too low.The cuff is not fastened properly.Fasten the cuff correctly. p.17
The unit does not measure. Readings are too high or too low.You moved your arm or body during the measurement.Make sure you remain very still and quiet during the measurement. p.17
The unit does not measure. Readings are too high or too low.The cuff position is not correct.Sit comfortably and still. Make sure the cuff is at the same level as your heart. p.17
The unit does not measure. Readings are too high or too low.Taking too many readings on the same arm in a short period of time.Relax five minutes before each measurement. p.17
The value is different from that measured at a clinic or doctor’s office.The healthcare profes- sional may be using a different sized cuff.See Pg. E-12 "Answers to Why Your Readings Are Different Between Home and the Doctor’s Office." p.17
The value is different from that measured at a clinic or doctor’s office.Your measurements may be elevated by white coat hypertension.See Pg. E-11 "Why Measure Blood Pressure at Home." p.17

Ask about the LifeSource UB-328

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LifeSource UB-328

Be the first to ask — other owners or our team will answer.

Original document

LifeSource UB-328 manual PDF

20 pages·492 KB·Blood Pressure Monitor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…