EN
GarrettCom logo
Official user manual

GarrettCom Power Supply (IPS42)

36 pages·225 KB·Power Supply·PDF·ENDEFRITNLJA
GarrettCom Power Supply (IPS42)
Table of Contents 27 sections Magnum IPS42 Internal Power Supply · Installation and User Guide · for Edge Switch Family · Magnum ™ IPS42 Internal Power Supply for · … ShowHide
Page 1 of the GarrettCom Power Supply (IPS42) user manual — Magnum IPS42 Internal Power Supply
Page 1 · click to enlarge
Page 1

Magnum IPS42 Internal Power Supply

Installation and User Guide

for Edge Switch Family

GarrettCom Power Supply (IPS42) — Magnum IPS42 Internal Power Supply diagram (page 1)
Fig. 1 · Magnum IPS42 Internal Power Supply
GarrettCom Power Supply (IPS42) — Magnum IPS42 Internal Power Supply diagram (page 1)
Fig. 2 · Magnum IPS42 Internal Power Supply
Page 2 of the GarrettCom Power Supply (IPS42) user manual — Magnum ™ IPS42 Internal Power Supply for
Page 2 · click to enlarge
Page 2

GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal

Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch

Magnum ™ IPS42 Internal Power Supply for

Installation and User Guide

Edge Switch Family

UL is a registered trademark of Underwriters Laboratories

Part #84-00181Z Rev. B

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

are trademarks of GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom Power Supply (IPS42) user manual — Magnum ™ IPS42 Internal Power Supply for
Page 3 · click to enlarge
Page 3

Copyright © 2009 GarrettCom, Inc. All rights reserved. No part of this publication may

GarrettCom, Inc. reserves the right to change specifications, performance characteristics

Internal Power Supply products, consult Section 4, Troubleshooting, of this User Guide.

contains no user serviceable parts. Attempted service by unauthorized personnel shall

render all warranties null and void. If problems are experienced with Magnum IPS42

be reproduced without prior written permission from GarrettCom, Inc.

Printed in the United States of America.

and/or model offerings without notice.

Page 4 of the GarrettCom Power Supply (IPS42) user manual — Magnum ™ IPS42 Internal Power Supply for
Page 4 · click to enlarge
Page 4

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and

found to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user, at his own expense, will be required to take

Radio Frequency Interference Statement

whatever measures may be required to correct the interference.

Federal Communications Commission

Page 5 of the GarrettCom Power Supply (IPS42) user manual — Magnum ™ IPS42 Internal Power Supply for
Page 5 · click to enlarge
Page 5

which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable

ONLY be replaced by GarrettCom personnel through the RMA process.

2. 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product.
3. This product shall be provided with a maximum 10A DC Listed fuse or
4. The external power supply for DC units shall be Listed, Direct Plug In

power unit, marked Class 2, or listed ITE Power Supply, marked LPS,

5. Product does not contain user replaceable fuses. Any internal fuses can
1. This product is to be installed Only in Restricted Access Areas

(Dedicated Equipment Rooms, Electrical Closets, or the like).

circuit breaker in the supply circuit when connected to a 48V

Electrical Safety requirements:

rated output current.

centralized source.

Page 6 of the GarrettCom Power Supply (IPS42) user manual — Phone (510) 438-9071
Page 6 · click to enlarge
Page 6

Please use the mailing address, phone, fax numbers and email address listed below:

Websitehttp://www.GarrettCom.com
Emailsupport@ garrettcom.com

47823 Westinghouse Dr. Fremont, CA 94539

GarrettCom, Inc.

Phone (510) 438-9071

Fax (510) 438-9072 · Contacting GarrettCom, Inc

Page 7 of the GarrettCom Power Supply (IPS42) user manual — Phone (510) 438-9071
Page 7 · click to enlarge
Page 7
Page 7 of the GarrettCom Power Supply (IPS42) user manual — Phone (510) 438-9071
Page 8 of the GarrettCom Power Supply (IPS42) user manual — Rev. A 07/09: Initial Release
Page 8 · click to enlarge
Page 8

4.2 When Calling for Assistance 24

4.3 Return Material Authorization (RMA) Procedure 25

4.4 Shipping and Packaging Information 26

APPENDIX A: WARRANTY INFORMATION 28

Rev. B 11/09Updated DIN Rail mount photo (Sec. 3.1.2)

Rev. A 07/09: Initial Release

Revisions

Page 9 of the GarrettCom Power Supply (IPS42) user manual — 1.1 Technical Specifications
Page 9 · click to enlarge
Page 9
Std. Terminal Block for DualSRCA: “-, GND, +”, B: “-, GND, +”
Power Consumption10 Watts typical for a 4+2 port fiber model
Power Consumption10 Watts typical for a 4+2 port fiber model
AC100-250 VAC, 47 to 63 Hz, auto ranging
Surge RatingIEC 61000-4-3, Class 3/4 (4KV for DC)
Std. Recessed Terminal Block“-, GND, +”, UL Listed

125VDC: Input 100 to 250VDC nominal 48VDC: Input 44 to 57VDC 24VDC: Input 20 to 36VDC Surge Rating: IEC 61000-4-3, Class 3/4 (4KV for DC)

AC/DC Power Supply (Model IPS42-AC/DC):

DC Power Supplies for Dual Source DC:

Power InputDC: 100-250 VDC

1.1 Technical Specifications

1.0 SPECIFICATIONS

Page 10 of the GarrettCom Power Supply (IPS42) user manual — Mechanical Specifications:
Page 10 · click to enlarge
Page 10
UL 60950 “Component Parts” rating-40° to 140°F (-40° to 60°C)

6.0 in H x 5.5 in W x 1.7 in D (15.2 cm x 14.0 cm x 4.3 cm) Weight: all models: 1.5 lbs. (0.68 kg)

Power Consumption10 Watts typical for a 4+2 port fiber model

IEC 60068 “Type Test” exceeds -40° to 185°F (-40° to 85°C)

AC Power Connectorstandard IEC 320 male, recessed
Power Input100-250 VAC, 47 to 63 Hz, auto ranging
Conformal coating (humidity protection)optional
Relative Humidity5% to 95% (non-condensing)

Enclosure: Rugged sheet metal (Aluminum).

Altitude-200 to 13000FT (-60 to 4000M)

AC Power Supply (Model IPS42-AC)

Storage-60 ° to 212°F (-50 ° to 100°C)

Dimensions of the IPS42 unit:

Mechanical Specifications:

Operating Environment:

Page 11 of the GarrettCom Power Supply (IPS42) user manual — Cooling Method:
Page 11 · click to enlarge
Page 11

Mean Time Between Failure (MTBF) – over 15 years, Telcordia (Bellcore) Method

All IPS42 models feature convection cooling for temperature un-controlled locations. All

models have closed cases to withstand dirt and use special thermal techniques to transfer

Internal 60VA relay contact: Open for power Off, closed for power On (Hardware).

DIN-Rail mounting optionModel # DIN-RAIL-MC2 (see Section 3.1)

ALARM RELAY Terminal Block, four screw terminals:

Metal mounting clips for panel mounting: included

heat to the outside of the case for cooling.

Cooling Method:

Mounting options

Page 12 of the GarrettCom Power Supply (IPS42) user manual — Cooling Method:
Page 12 · click to enlarge
Page 12

UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A

WarrantyThree years, return to factory Made in USA

IEC 61850 EMC and Operating Conditions Class C Power Substations

NEBS L3 and ETSI compliant including vibration, shock and altitude

IEEE 1613 Env. Standard for Electrical Power Substations

NEMA TS-2 and TEES for traffic control equipment

Agency Approvals and Standards Compliance:

Page 13 of the GarrettCom Power Supply (IPS42) user manual — IPS42-AC/DC
Page 13 · click to enlarge
Page 13

ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without

IPS42-AC/DCInternal Power Supply chassis for use with any ES42H or ES42P

supply) as a separate line item. Rated 100 to 250 VAC or VDC. Power input via recessed

Series Edge Switch. Requires simultaneous ordering of an ES42 (without external power

IPS42-125VDC-DualSRCInternal Power Supply chassis for use with any

external power supply) as a separate line item. Rated 100 to 250 VDC, Dual Source.

Power input via recessed terminal block, UL Listed and Surge protected.

1.2 Summary of models and descriptions for IPS42 Series:

IPS42-AC/DC

terminal block, UL Listed and Surge protected.

Page 14 of the GarrettCom Power Supply (IPS42) user manual — IPS42-xxVDC-DualSRC
Page 14 · click to enlarge
Page 14

ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without

ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without

external power supply) as a separate line item. Rated 44 to 57 VDC, Dual Source. Power

external power supply) as a separate line item. Rated 20 to 36 VDC, Dual Source. Power

IPS42-48VDC-DualSRCInternal Power Supply chassis for use with any
IPS42-24VDC-DualSRCInternal Power Supply chassis for use with any

input via recessed terminal block, UL Listed and Surge protected.

input via recessed terminal block, UL Listed and Surge protected.

IPS42-xxVDC-DualSRC

Page 15 of the GarrettCom Power Supply (IPS42) user manual — IPS42-AC
Page 15 · click to enlarge
Page 15

supply) as a separate line item. Standard worldwide AC power input via standard IEC320

Series Edge Switch. Requires simultaneous ordering of an ES42 (without external power

IPS42-ACInternal Power Supply chassis for use with any ES42H or ES42P

DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one IPS42 Series product

Conformal Coating (for high humidity and “tropical” applications) - request quote.

GarrettCom Power Supply (IPS42) — IPS42-AC diagram (page 15)
Fig. 3
GarrettCom Power Supply (IPS42) — IPS42-AC diagram (page 15)
Fig. 4

recessed male connector, UL Listed and Surge protected.

IPS42-AC

(see Section 3.1)

Accessories

Page 16 of the GarrettCom Power Supply (IPS42) user manual — 2.0 INTRODUCTION
Page 16 · click to enlarge
Page 16

product; notify the carrier immediately of any damage that you believe occurred during

shipment or delivery. Inspect the contents of this package for any signs of damage and

2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this

1 Magnum IPS42 Series Internal Power Supply for Edge Switch

1 set Metal panel mounting clips and screws (4 each)

1 Power Cord Installation Kit (if applicable)

1 IPS42 User Guide (this manual)

ensure that the items listed below are included.

1 ES42 User Guide

2.0 INTRODUCTION

This package should contain:

Page 17 of the GarrettCom Power Supply (IPS42) user manual — 2.0 INTRODUCTION
Page 17 · click to enlarge
Page 17

container. Be sure to keep the shipping container should you need to ship the unit at a later

date. In the event there are items missing or damaged contact your supplier. If you need to

return the unit, use the original shipping container. Refer to Section 4 Troubleshooting, for

2.2 Product Description The Magnum IPS42 chassis brings big-switch internal power supplies to compact

125VDC substation power or into worldwide AC power. Dual-source models operate from either of two DC power inputs and provide high availability. Any one of the models of the

Remove the Magnum IPS42 Series Internal Power Supply from the shipping

unmanaged industrial edge switches. The AC/DC model allows the user to connect into

ES42s may be ordered concurrently with any of the five IPS42 models.

specific return procedures.

Page 18 of the GarrettCom Power Supply (IPS42) user manual — 2.0 INTRODUCTION
Page 18 · click to enlarge
Page 18

Worldwide AC power input with standard IEC 320 recessed male power plug

IPS42 Series have a robust design and are packaged in a rugged sheet metal

suppression. The only High Voltage AC/DC Ethernet unit on the market

„ 100 to 250V range, 4KV surge protected AC/DC models are rated at 100-250V with a maximum of 4KV surge

125VDC, 48VDC and 24VDC models are equipped with Dual-Source inputs for high availability.

enclosure to ensure high reliability and durability even when placed in

„ Rugged metal case, Industrial grade

industrial or outdoor applications.

that is UL Listed for user safety.

„ Dual-Source power input

2.3 Features and Benefits

„ For AC models

Page 19 of the GarrettCom Power Supply (IPS42) user manual — 3.0 INSTALLATION
Page 19 · click to enlarge
Page 19

The compact and lightweight design of the Magnum IPS42 Series allows it to be

easily installed in almost any location. A Velcro strip may be used for mounting the unit on

a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or shelf.

This section describes the installation of the Magnum IPS42 Internal Power

Alternatively, metal mounting clips and screws are included for a rugged and secure

Supply, including location, mounting, power cord and media connections.

3.0 INSTALLATION

3.1 Locating the IPS42

mounting in any orientation.

Page 20 of the GarrettCom Power Supply (IPS42) user manual — 3.0 INSTALLATION
Page 20 · click to enlarge
Page 20

Installation of the Magnum IPS42 Series of products is a simple procedure. The

screws to mount the unit securely on a panel or wall. It is recommended to mount the units

associated cabling. Make sure the unit is installed in a location that is easily accessible to

an AC power outlet or the appropriate DC source and where cooling is not inhibited. The

Each Mangum IPS42-Series is supplied with metal mounting brackets and

vertically (see page 14) for proper cooling and long-life reliability. It is also advisable to

installation location is dependent upon the physical layout of the Ethernet network and

mount the unit with space for air movement around the top and the sides, typically a

3.1.1 Mounting Dimensions for IPS42 with metal brackets

green Power (PWR) LED must turn ON when power is applied.

minimum of 1 inch.

Page 21 of the GarrettCom Power Supply (IPS42) user manual — 3.0 INSTALLATION
Page 21 · click to enlarge
Page 21

or wall behind it, creating a rear space of about ¼ inch or 1cm. This allows air

For best cooling of the IPS42 Series, attach the metal brackets to metal (rather than

wood or plastic). Attaching to metal helps conduct heat away from the IPS42 Series

Since the IPS42 Series has special internal thermal techniques (patent pending) to

move the heat generated by the electronic components inside into the case, the case

through the metal brackets and into the metal support structure.

circulation and cooling of the rear part of the case.

may be quite warm to the touch during normal operation.

Page 22 of the GarrettCom Power Supply (IPS42) user manual — 3.0 INSTALLATION
Page 22 · click to enlarge
Page 22

The unit is mounted using the brackets as shown in the illustration above. The spacing for

the mounting screws into the supporting wall or panel is a rectangle 15.49 x 12.89 cm

GarrettCom Power Supply (IPS42) — 3.0 INSTALLATION diagram (page 22)
Fig. 5

(6.10 x 5.075 inches) center-to-center.

Page 23 of the GarrettCom Power Supply (IPS42) user manual — 3.0 INSTALLATION
Page 23 · click to enlarge
Page 23
GarrettCom Power Supply (IPS42) — 3.0 INSTALLATION diagram (page 23)
Fig. 6

A Magnum IPS42 is shown with the

The metal DIN-Rail mounting hardware is

optional and needs to be ordered as a separate item,

Ethernet environments, is available for DIN-Rail

e.g. Model #DIN-RAIL-MC2. It comes with four

3.1.2 DIN-Rail mounting option The Magnum IPS42 Power Supply,

designed for use in “Factory Floor” Industrial

mounting in an enclosure having DIN Rails.

screws to attach the bracket to the MC unit.

DIN-RAIL-MC2 bracket installed

Page 24 of the GarrettCom Power Supply (IPS42) user manual — 3.0 INSTALLATION
Page 24 · click to enlarge
Page 24

For IPS42-DC w/Dual Source and AC/DC models that do not have the power

GarrettCom Power Supply (IPS42) — 3.0 INSTALLATION diagram (page 24)
Fig. 7

cord installed at the factory, follow the procedures as described below. For detailed

reliable operation, withstands higher temperature

environments, and provides the power choices to

lock terminal block for installing the power cord.

The units are provided with a 4-position screw-

technical specifications, refer to Section 1.1 of

the user to deploy in uncontrolled temperature

The IPS42 Internal Power Supply provides

3.2 Power Cord Installation

(shown in fig. 3.2a)

this User Guide.

environments.

Page 25 of the GarrettCom Power Supply (IPS42) user manual — 3.0 INSTALLATION
Page 25 · click to enlarge
Page 25
GarrettCom Power Supply (IPS42) — 3.0 INSTALLATION diagram (page 25)
Fig. 8

Use the Power Cord installation kit (items for Dual Source shown in Fig. 3.2b) to connect

b. Strip the wire ends of the power

3.2c). Tighten the locking screws to secure.

cord and place into the appropriate

hole in the terminal block (see Fig.

a. Slide the power cord cover

(pictured in Fig. 3.2b) over the

the power cord to the unit.

accepts 28-16 AWG wire.

cordage to be used.

one protective bushing.

Page 26 of the GarrettCom Power Supply (IPS42) user manual — 3.0 INSTALLATION
Page 26 · click to enlarge
Page 26

f. Attach a Safety Ground to the Grounding post of the IPS42 case. (see Fig. 3.2a)

For Dual Source models, positions A and B will be used.

For Single Source models, only position A will be used.

e. Secure the assembled power cord cover to the IPS42 case. (see Fig. 3.2e)

d. Secure the assembled terminal block to the mating piece of the unit.

c. Install the protective bushings and secure to the power cord cover.

secured in the terminal block.

GarrettCom Power Supply (IPS42) — 3.0 INSTALLATION diagram (page 26)
Fig. 9

(see Fig. 3.2d)

Page 27 of the GarrettCom Power Supply (IPS42) user manual — (-) (GND)
Page 27 · click to enlarge
Page 27

BLUE or WHITE (-)

GRN/YLW or GREEN (GND)

BROWN or BLACK (+)

GarrettCom Power Supply (IPS42) — (-) (GND) diagram (page 27)
Fig. 10
GarrettCom Power Supply (IPS42) — (-) (GND) diagram (page 27)
Fig. 11

(-) (GND)

(+)

Page 28 of the GarrettCom Power Supply (IPS42) user manual — (-) (GND)
Page 28 · click to enlarge
Page 28
GarrettCom Power Supply (IPS42) — (-) (GND) diagram (page 28)
Fig. 12

supply inside of the Magnum IPS42-Series Power Supply.

monitoring wires at the green terminal block.

feature, standard on Magnum IPS42-Series,

provides Normally Closed (NC) contacts to

close when there is power on the main board

“Hardware operated Alarm” because the NC

3.3 Hardware operated Alarm Contact The two screw Alarm Contacts

which the user can attach one set of status

The NC Alarm Contact is held

contacts will open when internal power is

lost, either from an external power down

condition or by the failure of the power

inside of the IPS42. This provides a

Page 29 of the GarrettCom Power Supply (IPS42) user manual — 4.0 TROUBLESHOOTING
Page 29 · click to enlarge
Page 29

IPS42 Series Internal Power Supply is a straightforward procedure (see INSTALLATION,

Should problems develop during installation or operation, this section is intended

to help locate, identify and correct these types of problems. Please follow the suggestions

procedures described in this section or if the Magnum IPS42 Series Internal Power Supply

1. Four-position terminal block (positions 1 & 2) as shown in Figure 4.4a 2. The Alarm Relay contact connected to the two terminals (1, 2) is hardware operated. 3. By default it is NC (normally closed). It will open if there is any loss of power to the electronics inside of the unit.

consistently high performance in all network environments. The installation of Magnum

Section 3.0); the operation is also straightforward and is discussed in the included ES42

is not performing as expected, do not attempt to repair the unit; instead contact your

listed below prior to contacting your supplier. However, if you are unsure of the

All Magnum Ethernet products are designed to provide reliability and

supplier for assistance or contact GarrettCom Customer Support.

4.0 TROUBLESHOOTING

User Guide.

Page 30 of the GarrettCom Power Supply (IPS42) user manual — 4.0 TROUBLESHOOTING
Page 30 · click to enlarge
Page 30
3. If the fiber port does not link up while connecting to other device, do a quick

4.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back

Loop test to test the fiber transceiver is functional or not. Use a short patch

receive to the fiber port transceiver. If the Link Led turns solid green, then

to the Installation Section of the applicable chapter of this manual. Also

2. Check the cables and connectors to ensure that they have been properly

connected and the cables/wires have not been crimped or in some way

impaired during installation. (About 90% of network downtime can be

cable of fiber and connect one end of cable to transmit and other end of

check to make sure that the various components of the network are

attributed to wiring and connector problems.)

the fiber port is functional and working.

interoperable.

Page 31 of the GarrettCom Power Supply (IPS42) user manual — 4.0 TROUBLESHOOTING
Page 31 · click to enlarge
Page 31

functioning and appropriate electrical outlet. Use the PWR LEDs to verify

5. If the problem is isolated to a network device other than the Magnum IPS42

Series product, it is recommended that the problem device is replaced with a

known good device. Verify whether or not the problem is corrected. If not,

go to Step 6 below. If the problem is corrected, the Magnum IPS42 Series

4. Make sure that an AC power cord is properly attached to each Magnum

IPS42 Series unit. Be certain that the AC power cord is plugged into a

6. If the problem continues after completing Step 5 above, contact your

supplier of the Magnum IPS42 Series unit or if unknown, contact

product and its associated cables are functioning properly.

GarrettCom, Inc. by fax, phone or email -

(support@garrettcom.com) for assistance

each unit is receiving power.

Page 32 of the GarrettCom Power Supply (IPS42) user manual — 4.0 TROUBLESHOOTING
Page 32 · click to enlarge
Page 32
2. An accurate list of GarrettCom product model(s) involved, with serial number(s).

Include the date(s) that you purchased the products from your supplier.

including convenient computers, workstations, terminals and printers; plus, the

various network media types being used, along with diagram of network setup.

3. It is useful to include other network equipment models and related hardware,
4. A record of changes that have been made to your network configuration prior

d. Any particular application that, when used, appears to create the problem;

to the occurrence of the problem. Any changes to system administration

1. A complete description of the problem, including the following points:

4.2 When Calling for Assistance Please be prepared to provide the following information.

b. Situations/Environment when the problem occurs;

c. The components/devices involved in the problem;

procedures should all be noted in this record.

a. The nature and duration of the problem;

Page 33 of the GarrettCom Power Supply (IPS42) user manual — 4.0 TROUBLESHOOTING
Page 33 · click to enlarge
Page 33

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

4.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization

(RMA) number. To obtain an RMA number, please use this URL -

Failure symptoms (including a full description of the problem)

Please have the following information readily available:

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

Name of your company / institution

Serial Number (or Invoice Number)

Your shipping address · Date of installation · Product name

Page 34 of the GarrettCom Power Supply (IPS42) user manual — 4.0 TROUBLESHOOTING
Page 34 · click to enlarge
Page 34

warranty. Testing and repair of product that is not under warranty will result in a customer

1. Package the unit carefully. It is recommended that you use the original container

if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for

GarrettCom will carefully test and evaluate all returned products, will repair products that

are under warranty at no charge, and will return the warranty-repaired units to the sender

details). However, if the problem or condition causing the return cannot be duplicated by

shipping protection. (You may retain all connectors and this Installation Guide)

Should you need to ship the unit back to GarrettCom, please follow these instructions:

with shipping charges prepaid (see Warranty Information, Appendix A, for complete

GarrettCom reserves the right to charge for the testing of non-defective units under

No Problem Found.

4.4 Shipping and Packaging Information

GarrettCom, the unit will be returned as:

(user) charge.

Page 35 of the GarrettCom Power Supply (IPS42) user manual — 47823 Westinghouse Dr. Fremont, CA 94539
Page 35 · click to enlarge
Page 35

This material may cause electro-static shock damage to the unit.

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.
3. GarrettCom is not responsible for your return shipping charges.

47823 Westinghouse Dr. Fremont, CA 94539

Attn.: Customer Service

4. Ship the package to: GarrettCom, Inc.
Page 36 of the GarrettCom Power Supply (IPS42) user manual — APPENDIX A: WARRANTY INFORMATION
Page 36 · click to enlarge
Page 36

During this warranty period, GarrettCom will repair or, at its option, replace components in

has been damaged by misuse, misapplication, or as a result of service or modification other

This warranty will not be effective if, in the opinion of GarrettCom, the product

GarrettCom, Inc. warrants its products to be free from defects in materials and

workmanship for a period of three (3) years from the date of shipment by GarrettCom.

the products that prove to be defective at no charge other than shipping and handling,

than by GarrettCom. GarrettCom reserves the right to make a charge for handling and

inspecting any product returned for warranty repair which turns out not to be faulty.

provided that the product is returned pre-paid to GarrettCom.

APPENDIX A: WARRANTY INFORMATION

Ask about the GarrettCom Power Supply (IPS42)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom Power Supply (IPS42)

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom Power Supply (IPS42) manual PDF

36 pages·225 KB·Power Supply·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…