EN
GarrettCom logo
Official user manual

GarrettCom Ethernet Switch (P62F)

36 pages·563 KB·Network Card·PDF·ENDEFRITNLJA
GarrettCom Ethernet Switch (P62F)
Table of Contents 41 sections Hardened Ethernet Switches · 1.0 SPECIFICATIONS · 1.1 Technical Specifications · 1.2 Ordering Information · … ShowHide
Hardened Ethernet Switchesp.11.0 SPECIFICATIONSp.61.1 Technical Specificationsp.61.2 Ordering Informationp.92.0 INTRODUCTIONp.112.1 Inspecting the Package and Productp.112.2 Product Descriptionp.122.2.1 Magnum P62-Series chassis w/fiber SC (m.m. or s.m) connectorsp.132.2.2 Managed mP62 chassis with fiber SC (m.m. or single-mode) portsp.142.2.3 Managed Network Software ( MNS-mP ) for Magnum mP62p.152.2.4 Connecting the Console Terminal to Magnum mP62 (Management)p.162.3 Fiber port, SC Connectorsp.172.4 Frame Buffering and Latencyp.172.5 Features and Benefitsp.192.6 Applicationsp.203.0 INSTALLATIONp.233.1 Locating Magnum P62F-Series 10/100Mb Ethernet Switchesp.233.1.1 Mounting position and materialsp.233.1.2 Mounting dimensionsp.233.2 Connecting Ethernet Media, and Special Strain-relief featurep.253.2.1 Connect Twist Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shield)p.253.2.2 Connecting Fiber Optic SC-type, "Snap-In"p.263.2.3 Connecting Fiber Optic ST-type, “Snap-In” (Optional)p.263.2.4 Connecting Single-Mode Fiber Opticp.263.2.5 Power Budget Calculations for P62-Series Fiber Mediap.273.2.6 Connections to NICs which support Auto-Negotiation, RJ-45 portsp.283.3 Powering the Magnum P62-Series Hardened Switchp.283.3.1 Power P62F and mP62 models, for –48V and 24V DC pwr inputp.283.3.2 Power the P62-5V models w/Ext AC Power Supply (PSX-A)p.293.3.3 Power the P62-5V w/DC Pwr Supply (PSX-T) at 125/250 VDCp.293.4 Cable Strain Relief Feature on all P62-Series modelsp.31OPERATIONp.324.1 Dual-Speed Functionality, and Switchingp.324.2 Auto-negotiation and Speed-sensingp.334.3 LED’s for P62-Series Hardened Switchp.335.0 TROUBLESHOOTINGp.345.1 Before Calling for Assistancep.345.2 When Calling for Assistancep.355.3 Return Material Authorization (RMA) Procedurep.355.4 Shipping and Packaging Informationp.36APPENDIX A: WARRANTY INFORMATIONp.36
Page 1 of the GarrettCom Ethernet Switch (P62F) user manual — Installation and User Guide
Page 1 · click to enlarge
Page 1

Hardened Ethernet Switches

Magnum P62-Series (P62F and managed mP62 models)

GarrettCom Ethernet Switch (P62F) — Hardened Ethernet Switches diagram (page 1)
Fig. 1 · Hardened Ethernet Switches

Installation and User Guide

GarrettCom Ethernet Switch (P62F) — Installation and User Guide diagram (page 1)
Fig. 2 · Installation and User Guide
GarrettCom Ethernet Switch (P62F) — Installation and User Guide diagram (page 1)
Fig. 3 · Installation and User Guide
Page 2 of the GarrettCom Ethernet Switch (P62F) user manual — Installation and User Guide
Page 2 · click to enlarge
Page 2

Printed in the United States of America.

GarrettCom, Inc.

of this publication may be reproduced without prior written permission from

Copyright 2002 GarrettCom, Inc. All rights reserved. No part

trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.

GarrettCom, Magnum, Personal Switch, and Link-Loss-Learn (patent pending) are

UL is a registered trademark of Underwriters Laboratories

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

Hardened Switch product, consult Section 5, Troubleshooting, of this User Guide.

warranties null and void. If problems are experienced with a Magnum P62-Series

serviceable parts. Attempted service by unauthorized personnel shall render all

Installation and User Guide

Magnum P62-Series (P62F and managed mP62 models) Hardened Ethernet Switches

Part #84-00092, (Rev F 12/02)

Trademarks

Page 3 of the GarrettCom Ethernet Switch (P62F) user manual — email support@garrettcom.com
Page 3 · click to enlarge
Page 3

required to take whatever measures may be required to correct the interference.

area is likely to cause interference, in which case the users at their own expense will be

when operated in a commercial environment. Operation of this equipment in a residential

FCC rules, which are designed to provide reasonable protection against such interference

a Class A computing device in accordance with the specifications in Subpart J of Part 15 of

interference to radio communication. It has been tested and found to comply with the limits for

and used properly, that is in strict accordance with the manufacturer's instructions, may cause

Please use the mailing address, phone and fax numbers and email address listed below:

This equipment generates, uses and can radiate frequency energy and if not installed

Radio Frequency Interference Statement

Websitehttp://www.GarrettCom.com

email [email protected]

GarrettCom, Inc. 213 Hammond Ave. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072

Contacting GarrettCom, Inc · Federal Communications Commission

Page 4 of the GarrettCom Ethernet Switch (P62F) user manual — ETHERNET CONNECTIVITY PRODUCTS
Page 4 · click to enlarge
Page 4

The “X-line” of configurable MiXed Media products: Stackable Concentrators, SNMP optional, 13-Ports Repeater Port Modules (RPMs), 6 types for Ethernet media Bridge Port Modules (BPMs), 4 types, for segment isolation Transceivers, 10Mb series Mini-Transceivers and Coax Models Dec, 02

8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series, for offices and Hardened models for industrial applications. All media combinations, incl. fiber ST, SC, mm., single mode

Personal Hubs, 10Mb series

8-port, with two switched ports (1 fiber built in)

8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb

10Mb series and 100Mb series, both w/ optional port modules, AC and DC power Personal Switches, 10/100Mb

Stackable Hubs, SNMP Optional

ITS Blade 8-port 10/100 “switch-on-a-card” for Model 2070 Traffic Controller Chassis

cPCI Blade 12-port 10/100 “hub-on-a-card” for Compact PCI chassis rear I/O

Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing. AC and DC power

Mixed-Media Fiber Hub, 16-port Stackable,10/100 auto-sensing, AC and DC power

6 10/100 and 2 100Mb fiber ports, managed and unmanaged models, all fiber types.

"DESIGNED AND MANUFACTURED IN THE USA" Overview GarrettCom, Inc. offers the Magnum line of Ethernet LAN connectivity products with industry-standard functionality. Magnum products are heavy duty, feature fiber-built-in ports, and have AC and DC power options to make them suitable for a variety of Industrial and Carrier Class applications. 6K25 Managed Fiber Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix- and match. Features SFF fiber for up to 25 fiber ports in a 1U unit. Configurable. 4K-Series Switches, 100 and 10 Mbps copper ports with optional 100Mb fiber ports, regular and Reverse rack-mount models, AC and DC power options, heavy duty specs. Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and mixed-media types, full switching performance, AC and DC power options. P62-Series “Outdoor” Ethernet Switches, for temperature uncontrolled applications,

ETHERNET CONNECTIVITY PRODUCTS

MAGNUM

Page 5 of the GarrettCom Ethernet Switch (P62F) user manual — Table of contents
Page 5 · click to enlarge
Page 5

Table of contents

Hardened Ethernet Switchesp.11.0 SPECIFICATIONSp.61.1 Technical Specificationsp.61.2 Ordering Informationp.92.0 INTRODUCTIONp.112.1 Inspecting the Package and Productp.112.2 Product Descriptionp.122.2.1 Magnum P62-Series chassis w/fiber SC (m.m. or s.m) connectorsp.132.2.2 Managed mP62 chassis with fiber SC (m.m. or single-mode) portsp.142.2.3 Managed Network Software ( MNS-mP ) for Magnum mP62p.152.2.4 Connecting the Console Terminal to Magnum mP62 (Management)p.162.3 Fiber port, SC Connectorsp.172.4 Frame Buffering and Latencyp.172.5 Features and Benefitsp.192.6 Applicationsp.203.0 INSTALLATIONp.233.1 Locating Magnum P62F-Series 10/100Mb Ethernet Switchesp.233.1.1 Mounting position and materialsp.233.1.2 Mounting dimensionsp.233.2 Connecting Ethernet Media, and Special Strain-relief featurep.253.2.1 Connect Twist Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shield)p.253.2.2 Connecting Fiber Optic SC-type, "Snap-In"p.263.2.3 Connecting Fiber Optic ST-type, “Snap-In” (Optional)p.263.2.4 Connecting Single-Mode Fiber Opticp.263.2.5 Power Budget Calculations for P62-Series Fiber Mediap.273.2.6 Connections to NICs which support Auto-Negotiation, RJ-45 portsp.283.3 Powering the Magnum P62-Series Hardened Switchp.283.3.1 Power P62F and mP62 models, for –48V and 24V DC pwr inputp.283.3.2 Power the P62-5V models w/Ext AC Power Supply (PSX-A)p.293.3.3 Power the P62-5V w/DC Pwr Supply (PSX-T) at 125/250 VDCp.293.4 Cable Strain Relief Feature on all P62-Series modelsp.31OPERATIONp.324.1 Dual-Speed Functionality, and Switchingp.324.2 Auto-negotiation and Speed-sensingp.334.3 LED’s for P62-Series Hardened Switchp.335.0 TROUBLESHOOTINGp.345.1 Before Calling for Assistancep.345.2 When Calling for Assistancep.355.3 Return Material Authorization (RMA) Procedurep.355.4 Shipping and Packaging Informationp.36APPENDIX A: WARRANTY INFORMATIONp.36
Page 6 of the GarrettCom Ethernet Switch (P62F) user manual — 1.0 SPECIFICATIONS 1.1 Technical Specifications
Page 6 · click to enlarge
Page 6

Packet-Processing Between Domains is non-blocking Filtering and Forwarding Rate from 100Mbps ports: 148,800 pps max Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max. Processing type: Store and Forward Auto-learning: 4K address table (16K on P62F), shared for all ports Packet buffers: 256KB, dynamically shared on all domains Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 5µs Path Delay Value: 50 BT on all ports

Ports Performance Fiber, and when an auto-negotiating port is operating at 100Mbps: Data Rate: 100Mbps When an RJ-45 auto-negotiating port is operating at 10 Mbps: Data Rate: 10 Mbps For mP62 models, RJ-45 ports are S/W controlled for speed and F/H duplex, crossover (MDI – MDIX) is automatically handled

1.0 SPECIFICATIONS 1.1 Technical Specifications

Maximum Ethernet Segment (or Domain) Lengths 10BASE-T (Unshielded twisted pair) - 100 m (328 ft) 100BASE-TX (CAT 5 UTP) - 100 m (328 ft) 100BASE-FX, full-duplex: (multi-mode) - 2.0 km (6,562 ft) 100BASE-FX, full-duplex: (single-mode) - 20.0 km (65,620 ft) 100BASE-FX, full-duplex: (single-mode, long) - 40.0 km (131,240 ft)

Operating Environment Ambient Temperature: -40°F to 170°F for mP62 (160°F for P62F) (-40°C to 75°C for mP62, 70°C for P62F)) Cold start down to -20°C Storage Temperature: -40° to 185°F (-40°C to 85°C) Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude: -200 to 50,00 ft. (-60 to 15,000m) “Plenum rated” per UL2043 fire tests IEC 529 rated IP51 (holds out dust, vertical water) Operating Shock and Vibration: Meets Bellcore GR-63-CORE Conformal coating (tropical humidity protection) optional, request quote

Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3u; 802.3x flow control For managed mP62 models, IEEE 802.1p QoS and 802.1d Spanning Tree For mP62 management software, see Section 2.2.3

Page 7 of the GarrettCom Ethernet Switch (P62F) user manual — 1.0 SPECIFICATIONS
Page 7 · click to enlarge
Page 7

Fiber Ports # 1 and 8 The switched fiber ports # 1 & 8 are fixed at full-duplex only, 100Mb speed. Mechanical Enclosure: Rugged 18-gauge high-strength steel case. Metal mounting plate included. Suitable for stand-alone, shelf, pedestal or wall mounting. The case also serves as a heat sink. The metal mounting base is included, 13-guage steel. (Without the base, the box size is only 7” high). Mounting holes in the base plate are a rectangle that measures 3.35” x 7.92” (8.5 x 20.1 cm) center to center. See Section 3.1.2 for additional mounting details. Dimensions (wall mounted): 1.70 in D x 5.75 in W x 8.8 in H (4.3 cm x 14.6 cm x 22.4 cm) Weight: 3.5 lb. (1.6 kg.) Cooling method: Convection, with case operating as a heat sink. Note: Internal thermal materials and techniques (patent pending) conduct heat from the electronic elements inside to the steel case which acts as a heat sink. Internal chip temperatures are only about 10°C above case ambient at steady state operation LED Indicators PWR: Steady ON when power applied SPEED: (when LINK is ON): ON = 100Mbps; OFF = 10 Mbps LINK/ACT: Steady ON for LINK with no traffic, blinking indicates port is transmitting / receiving. F/H (RJ-45 ports only): ON = full-duplex, OFF = half-duplex

Power Supply (Internal) 24VDC and -48VDC Power Supply Power Input Voltage: 20 to 70 VDC (auto-ranging), “-, GND, +” Power Consumption: 10 watts typical. DC-DC Converter Rating: 5VDC, 2Amps Power Supply (Ext.) 125VDC & 250VDC, (PSX-T) for P62-Series -5V only Power Input Voltage: 100 to 275 VDC (nominal rating of 125, 250VDC) Power Consumption: 15 watts typical. DC-DC Converter Rating: 5VDC, 3Amps Power Supply (External) AC Power Supply (PSX-A) for P62F-5V and mP62-5V AC Power Connector: IEC-type, male recessed at rear of Power Supply chassis Input Voltage: 85 to 264 VAC (auto-ranging) Input Frequency: 47 to 63 Hz (auto-ranging) Power Consumption: 15 watts typical Power Supply Rating: 3Amps at 5VDC

Full-duplex / Half -duplex on copper (RJ-45) switched Ports # 2 to 7 All the RJ-45 ports support Full / Half duplex and 10/100 speed, each inde- pendently auto-negotiating on P62F models; S/W controlled on mP62 models.

Network Cable Connectors -6 RJ-45 shielded female ports and 2 fiber port 100Mbps: Category 5 UTP/STP, fiber (50/125, 62.5/125 mm, or single-mode at 9/125 micron) 10 Mbps: Category 3, 4, 5 UTP (Note: auto-sensing does not sense cable type)

Page 8 of the GarrettCom Ethernet Switch (P62F) user manual — 1.0 SPECIFICATIONS
Page 8 · click to enlarge
Page 8
WarrantyThree years, return to factory Made in USA

UL2043 fire tests for “plenum rating”.

UL Listed (UL 60950), cUL, CB, CE Low Volt. Dir. & Electro-Magnetic Comp. IEEE P1613 (Draft) Environmental Standard for Electric Power Subs. (C37.90) Emissions: meets FCC Part 15, Class A, and ETSI

Over 10 years MTBF. Email sales@GarrettCom.com for details

Agency Approvals · MTBF (Bellcore method)

Page 9 of the GarrettCom Ethernet Switch (P62F) user manual — 1.2 Ordering Information
Page 9 · click to enlarge
Page 9

1.2 Ordering Information Magnum P62-Series, 10/100 Ethernet Switch Magnum P62F-AC-2MSC: P62F-AC Ethernet Switch with six 10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports. Has 16KB address table and 1.0 MB packet buffers. AC power input, 85-160vac 47-63Hz worldwide auto-ranging via PSX-A power source Extended Temp ( a separate unit). Steel case used as a heat sink, designed for use in environmentally challenged locations such as “outdoors” with extended temperatures. Magnum P62F-AC-1MISSC: Same as P62F-AC-2MSC, except one fiber port is 20km single-mode SC. (includes PSX-A unit) Magnum P62F-AC-2SSC: Same as P62F-AC-2MSC, except both fiber ports are 20km single-mode SC. (includes PSX-A unit) Magnum P62F-AC-NOF: P62F-DC Ethernet Switch, six 10/100 RJ-45 and no fiber ports. Has 16KB address table and 1.0MB packet buffers. AC power input 85- 260vac 47-63Hz worldwide auto-ranging, via PSX-A Power Source Extended Temp (a separate unit). Steel case used as a heat sink, designed for use in environmentally auto-ranging. Steel case used as a heat sink, designed for use in environmentally challenged locations such as “outdoors” with extended temperatures. Magnum P62F-2MSC: 8-port Ethernet Switch with two 100Mbps full-duplex switched fiber ports (multi-mode SC-type connector), and six half- or full-duplex switched RJ-45 10/100 auto-negotiating ports. Includes store-and-forward switching that filters and forwards data moving between the ports. The internal switch has 16K nodes address table and 1MB packet buffers. DC power input, 18-70VDC auto- ranging. Steel case acts as a heat sink. Rated for extended temperature. Magnum P62F-1M1SSC: Same as P62F-2MSC, but with one multi-mode SC-type and one 20Km single mode SC fiber connectors. Magnum P62F-2SSC: Same as P62F but with two 20Km sgl-mode SC-type fiber ports Magnum P62F-NOF: P62F-DC Ethernet Switch, six 10/100 RJ-45 and no fiber ports. Has 16KB address table and 1.0MB packet buffers. DC power input, 18-70VDC auto-ranging. Steel case used as a heat sink, designed for use in environmentally challenged locations such as “outdoors” with extended temperatures. Parts Magnum P62F-5V-2MSC: Same as P62F-2MSC, except with 5VDC input using military-type-screw-lock connector. Magnum P62F-5V-1M1SSC: Same as P62F-1,1SSC, except with 5VDC input using military-type-screw-lock connector. Magnum P62F-5V-2SSC: Same as P62F-2SSC, except with 5VDC input using military-type-screw-lock connector. Magnum P62F-5V-NOF: Same as P62F-NOF, except with 5VFC input via PSX-A using military-type screw lock connectors. Magnum PSX-5V-CBL (spare): 2-ft power cord with military type screw-lock connector, spare for PSX to P62F-5V power cord. Magnum PSX-A: P62F-5V Power Source for Extended Temperature, nominal AC input 115-240vac at 47-63HZ auto-ranging, 15 watts, 5VDC output at 3Amps. Steel case used as a heat sink. Extended temperature rated. Output power cord has military-style screw-lock plug. Mounts as a separate unit adjacent to a Magnum Model P62F-5V Switch. Magnum PSX-T: Same as PSX-A , except 125VDC to 250VDC input, terminal lugs for “+”, “-“, and GND

Page 10 of the GarrettCom Ethernet Switch (P62F) user manual — Managed P62-Series (mP62) Hardened Switches
Page 10 · click to enlarge
Page 10

Magnum P62 models with other fiber connector types and combinations available, request quote.

Magnum mP62-AC-2MSC: mP62-AC Managed Switch with six10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports. Software includes menu-driven user interface for ease of use, SNMP, QoS, Telnet, Security, STP, VLAN, BootP/DHCP. Has 4Knodes address table and 256K packet buffers. AC power input, 85-260vac 47-63Hz worldwide auto-ranging, via PSX-A Power Source Extended Temp (a separate unit). Steel case used a s a heat sink, designed for use in environmentally challenged location such as “outdoors” with extended temperatures. Magnum mP62-AC -1MISSC: Same as mP62-AC-2MSC, except one fiber port is 20km single-mode SC. (includes PSX-A) Magnum mP62-AC -2SSC: Same as mP62-AC-2MSC, except both fiber ports are 20km single-mode SC. (includes PSX-A) Magnum mP62-AC -NOF: mP62 –AC Ethernet Switch w/ six 10/100 RJ-45s, no fiber ports Magnum mP62-2MSC: mP62-DC Ethernet Switch, six 10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports. Software and buffers same as mP62-AC-2MSC. Dc power input, 18-70VDC auto-ranging Magnum mP62-1MISSC: Same as mP62-2MSC, except one fiber port is 20km single-mode SC. (No PSX unit required) Magnum mP62-2SSC: Same as mP62-2MSC, except both fiber ports are 20km single- mode SC. (No PSX unit required) Parts Magnum mP62-5V-2MSC*: Same as mP62-2MSC, except with 5VDC input using military- type screw-lock connector Magnum mP62-5V –1M1SSC*: Same as mP62-1M1SSC, except w/ 5VDC input using military-type screw-lock connector Magnum mP62-5V –2SSC*: Same as mP62-2SSC, except w/ 5VDC input using military- type screw-lock connector Magnum mP62-5V-NOF: Same as mP62-NOF, except w/ 5VDC input using military-type screw-lock connector Magnum PSX-5V-CBL (spare): 2ft. power cord with military –type screw-lock connector, spare for PSX to mP62-5V power cord. MST Conversion: Special Item, convert one standard P62-2MSC w/two MSC fiber ports to two MST fiber ports. *PSX unit or equal required to supply 5VDC input. For more information, see the PSX datasheet.

GarrettCom, Inc. reserves the right to change specifications, performance characteristics and / or model offerings without notice.

Managed P62-Series (mP62) Hardened Switches

Page 11 of the GarrettCom Ethernet Switch (P62F) user manual — 2.0 INTRODUCTION
Page 11 · click to enlarge
Page 11

specific return procedures.

return the unit, use the original shipping container. Refer to Chapter 5, Troubleshooting, for

GarrettCom, Inc. as soon as possible.

the product warranty, please complete and return the enclosed Product Registration Card to

sure to keep the shipping container should you need to ship the unit at a later date. To validate

(Optional, PSX-T, 125 or 250VDC)

(Optional, if AC power)

This package should contain:

included.

the contents of this package for any signs of damage and ensure that the items listed below are

notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect

2.1 Inspecting the Package and Product

2.0 INTRODUCTION

In the event there are items missing or damaged, contact your supplier. If you need to

Remove the Magnum P62-Series Hardened Switch from the shipping container. Be

1 PSX-T Power Source Extended Temp. unit

1 6 ft. long AC Power chord (for PSX-A Unit only)

1 PSX-A Power Source Extended Temp. unit

1 Product Registration Card

1 Installation and User Guide

1 Magnum P62-Series Hardened Switch (P62F-xxx or mP62-xxx)

Examine the shipping container for obvious damage prior to installing this product;

Page 12 of the GarrettCom Ethernet Switch (P62F) user manual — 2.2 Product Description
Page 12 · click to enlarge
Page 12

status information of each port. The Magnum P62-Series Hardened Switches generate high

changes and expansions. Top-mounted LEDs provide extra advantage for the user to observe the

nodes are automatically learned and maintained, adapting the switching services to network

data communication huts and pedestals, aeronautical installations and military sites.

boiler rooms, mines and quarries, irrigation and pipeline facilities, on-board ships, cell towers,

(plenum) spaces (see sect.3.3.1 for details) and ceiling mounts in commercial buildings, industrial

collection and control stations, unheated and or high temperatures locations, above-ceiling

cold of -40°C (-40°F). when properly installed (see Sec. 3.0).

can easily handle the extreme heat of 75°C (170°F) mP62 or 70°C (160°F) P62F and extreme

internal electronics and dissipate it. The efficient design of P62-Series high strength steel cases

Magnum P62’s high strength steel case functions as a heat sink to draw away the heat from the

multi-mode and single-mode SC-type fiber connectors. For special fiber port types, request quote.

normally configured and tested with Magnum P62 units in the factory and come available in

smoothly support multiple workgroups at 100Mbps or 10Mbps speed. The optional fiber ports are

Magnum P62-Series Hardened Switches provide the switching speed and the reliability to

The six copper (RJ-45) ports come with full / half-duplex-10/100-auto-negotiating ability. The

Control, Spanning Tree Protocol, Port-based VLAN, BootP / DHCP etc..

Menu-driven User Interface for ease of use, SNMP, QoS, Telnet, Password Security, Port Settings

(mP62) equipped with MNS-mP software supports managed edge-switch functions including

existing and mixed vendor Ethernet network because of its features and capability. The Managed

including our Managed (mP62..) version. The Managed mP62 can be easily deployed in an

connectivity to local nodes and devices. All these features come in one compact rugged unit.

coupled with the convenience of six switched 10/100Mb copper (RJ45) ports for easy

duplex switched fiber ports so that several units can be daisy-chained. These fiber ports are

/ low temperatures. Magnum P62-Series Hardened switches provide two built-in 100Mb full-

extended temperature applications and are suitable for use in environments with inhospitable high

2.2 Product Description

A Magnum P62-Series hardened Switch is easy to install and use. Addresses of attached

Applications for Magnum P62-Series Hardened Switches include roadside traffic data

Designed specifically to operate in uncontrolled temperature applications, the hardened

The two built-in fiber ports are designed with full-duplex 100Mbps switched capability.

The Magnum P62-Series hardened Switches are available in a wide variety of options,

The Magnum P62-Series Ethernet “Outdoor” Switches are designed to operate in

Page 13 of the GarrettCom Ethernet Switch (P62F) user manual — 2.2.1 Magnum P62-Series chassis w/fiber SC (m.m. or s.m) connectors
Page 13 · click to enlarge
Page 13

2.2.1 Magnum P62-Series chassis w/fiber SC (m.m. or s.m) connectors

with store-and-forward switching ability, filters all faulty packets to minimize traffic congestion.

buffers and a 4K-node address table for advanced performance. A Magnum P62-Series Switch,

extra protection.

performance plug-and-play operation in a rugged package. The high-strength steel enclosure gives

DC power input is featured for high reliability and convenience in out-of-the-way locations.

or –48VDC only. The DC input power supports a wide range, from 20-70 VDC auto-ranging.

the chassis. The DC Magnum P62-Series Model is typically used for power input of 24VDC

suitable for “outdoors” temperatures, road-side pedestals, control rooms and military use.

product to withstand environments with inhospitable high / low temperatures, and makes it

full/half (F/H) duplex indicators. The fiber ports (#1 and 8), have (LK/ACT) indicators only.

(LK/ACT) LEDs indicating traffic, 10/100 (ON for 100Mbps) LEDs indicating speed, and

progress or failed) for the unit. For each RJ-45 (ports # 2 -7), there are Link and Activity

LEDs are mounted on the top cover to conveniently indicate operating status of all ports.

in full-duplex mode only to provide higher bandwidth and longer distances on fiber. All the

(one on each side of the RJ-45 ports) as shown in the adjacent picture. The fiber ports operate

chassis has a half dozen RJ-45 twisted-pair ports and two 100Mbps full-duplex fiber ports

For DC-powered models, the DC power plug connector or “jack” is in the left front of

The rugged design of the case using high-strength rugged 18-gauge steel enables this

There is a power on (PWR) indicator and a SELF TEST (self-test at power up in

The Magnum P62-Series chassis houses one main PC board. The front side of the

Magnum P62F-5V Magnum P62F

GarrettCom Ethernet Switch (P62F) — 2.2.1 Magnum P62-Series chassis w/fiber SC (m.m. or s.m) connectors diagram (page 13)
Fig. 4 · 2.2.1 Magnum P62-Series chassis w/fiber SC (m.m. or…

Each P62-Series Hardened Switch is non-blocking on all ports and has large packet

Page 14 of the GarrettCom Ethernet Switch (P62F) user manual — 2.2.2 Managed mP62 chassis with fiber SC (m.m. or single-mode) ports
Page 14 · click to enlarge
Page 14

2.2.2 Managed mP62 chassis with fiber SC (m.m. or single-mode) ports

driven MNS-mP is specially developed to have its function configured easily by the users.

network user to configure the network as per their needs. The neat appearance of the MENU

The MENU driven MNS-mP CLI software is user friendly and easily operated by the

on the managed MP62 Switch to provide a secure and highly efficient network to its users.

BootP / DHCP etc. The virtual LAN supports the Port based VLAN only and is easily setup

user interface, SNMP, QoS, VLAN, STP, Port settings control, Password security, and

it can operate at higher (75`C) ambient temperatures than the P62F models.

applications and in harsh environments. It also has internal components rated at 85`C so that

utility software operating features to make this Switch suitable to deploy in mission-critical

GarrettCom Ethernet Switch (P62F) — 2.2.2 Managed mP62 chassis with fiber SC (m.m. or single-mode) ports diagram (page 14)
Fig. 5 · 2.2.2 Managed mP62 chassis with fiber SC (m.m. or si…

See Section 3.3 for detail description of the PSX-A and PSX-T external power sources.

style screw-lock plug provides a secure connection.

63Hz and is auto-ranging with 5VDC 3Amp Power output. For both models, the military

shield, fuses, and is diode-protected against accidental reverse polarity connection.

model (PSX-T) input power supports a range of 100-275VDC and comes with input safety

for power input of universal AC power using the Magnum PSX-A unit. The 125/250 VDC

The MNS-mP software supports managed edge-switch functions including menu-driven

The Managed mP62 model is equipped with industry standard network management and

The AC Power Source, PSX-A, is equipped with a worldwide range of 85-264vac, 47-

The Magnum P62-5V models are available with an External Power Source (Optional)

mP62-5V with the PSX-A = AC model

GarrettCom Ethernet Switch (P62F) — 2.2.2 Managed mP62 chassis with fiber SC (m.m. or single-mode) ports diagram (page 14)
Fig. 6 · 2.2.2 Managed mP62 chassis with fiber SC (m.m. or si…
GarrettCom Ethernet Switch (P62F) — 2.2.2 Managed mP62 chassis with fiber SC (m.m. or single-mode) ports diagram (page 14)
Fig. 7 · 2.2.2 Managed mP62 chassis with fiber SC (m.m. or si…

Magnum mP62-5V

Page 15 of the GarrettCom Ethernet Switch (P62F) user manual — 2.2.3 Managed Network Software ( MNS-mP ) for Magnum mP62
Page 15 · click to enlarge
Page 15

For additional information about MNS-mP, see the Magnum mP62’s Software User guide in pdf

configure the Magnum mP62 as a Managed Hardened Switch and activate the Software features.

2.2.3 Managed Network Software ( MNS-mP ) for Magnum mP62

Section 3.3.

same as for the other P62F models. For detailed descriptions of Power Supply options, see

outdoor solution.

NEMA 4 boxes, IP65 enclosures and similar waterproof enclosures to provide an all-weather

Switch’s package is IEC 529 rated IP51 and, while not waterproof, it can be placed in

the bottom to provide protection of the connectors from dirt and dust. The managed mP62

field, an mP62 is typically fastened vertically to a wall or pedestal, with cables connected at

communications huts and pedestals, and military field operation sites. When mounted in the

temperature industrial plant locations, commercial building above-the-ceiling locations, data

power utility plants, substations, roadside traffic control stations, unheated or high

(MNS-mP software) capability, and a convection-cooled sealed case, the mP62s are ideal for

high thermal dissipation features (patent pending), power supply flexibility, management

to a max of 75°C, which is 5°C more than the P62F product ratings of 70°C. Equipped with

feature is of no known benefit and should be turned off.

and application information. Without a redundant network topology, the Link-Loss-Learn

traffic in mP62s. See http://www.garrettcom.com/mp62.htm for additional information

immediate re-learning of the addresses of the attached devices results in fast re-routing of

they may improve network reliability and provide faster fault recovery accordingly. Thus the

Learn feature, Magnum mP62s are better able to handle some fault recovery situations, and

configurations, such as when Spanning Tree Protocol (STP) is in use. With the Link-Loss-

Ethernet Switch addresses issues that can occur when mP62’s are used in redundant network

operating recovery from a link loss. The Link-Loss-Learn feature of the Magnum mP62

use the Console Management Interface(CMI) to manage all functions of the switch.

Magnum mP62’s come with licensed MNS-mP software, which allows a user to

The AC/DC Power Supply options for the Managed mP62 Hardened Switches are the

Developed using unique thermal techniques (patent pending), mP62’s operate smoothly

In addition, the Link-Loss-Learn feature (patent pending) in mP62’s allows rapid

The serial (Console) port is provided on the right front of the Managed mP62 Switch to

Page 16 of the GarrettCom Ethernet Switch (P62F) user manual — 2.2.4 Connecting the Console Terminal to Magnum mP62 (Management)
Page 16 · click to enlarge
Page 16

software is also available in Section 2.2.1 ( above) of this manual.

mP62 Software Manual available on GarrettCom‘s FTP site. Information about MNS-mP

mP62 Hardened Switch configurations for Network Management, please refer to the Magnum

Fig. 2.2.2 Front View of Magnum mP62, Console port is located on the extreme

2.2.4 Connecting the Console Terminal to Magnum mP62 (Management)

MNS-mP software support information.

and Hardware for mP62’s can be accessed and download from Garrettcom’s FTP site.

All the MNS-mP Software related information and NEW releases related to MNS-mP Software

ftp://ftp.garrettcom.com/ or FTP client program by ftp.GarrettCom.com using

format, a separate document normally accessed via the web-browser,

GarrettCom Ethernet Switch (P62F) — 2.2.4 Connecting the Console Terminal to Magnum mP62 (Management) diagram (page 16)
Fig. 8 · 2.2.4 Connecting the Console Terminal to Magnum mP62…

Use a DB-9 “null modem” cable to connect the Magnum mP62 Console Port (the RS- 232 port on the mP62 Switch) to your PC, so that your PC becomes the mP62’s Console Terminal.

Users can also email: support@GarrettCom.com for further information.

Or please visit www.GarrettCom.com/techsupport and look for Magnum mP62’s

passwordftpuser
userftpuser

right of the Hardened Switch

Console port

Page 17 of the GarrettCom Ethernet Switch (P62F) user manual — 2.3 Fiber port, SC Connectors
Page 17 · click to enlarge
Page 17

greatest.

forward operation is that more bandwidth is available for good packets when the traffic load is

Since collisions and bad packets are more likely when traffic is heavy, the result of store-and-

indiscriminate cut-through forwarding is greater traffic congestion, especially at peak activity.

with a bad CRC (the entire frame must be present in order for CRC to be calculated), the result of

late collisions, to be forwarded to add to the network traffic. Since there is no way to filter frames

connected. The "cut-through" technique permits collision fragment frames, which are a result of

frame latency, they will also permit bad frames to propagate out to the Ethernet segments

bandwidth to be used for valid information.

are good packets). This eliminates the propagation of bad packets, enabling all of the available

technique ensures that all forwarded frames are of a valid length and have the correct CRC, (i.e.,

(or packet) is loaded into the Switch’s memory and inspected before forwarding can occur. This

2.4 Frame Buffering and Latency

end of the cable in order for each LINK LED to provide a valid indication of operating conditions.

P62-Series unit via a cable. A proper link (LK light) must be made between both devices at each

fiber cable distances for installation versatility. A fiber port of a P62F is shown here,

backbone connection that supports long (up to 20km single-mode, or 40km special “long-reach”)

fiber port performs as a switched port and as a traffic domain, providing a high bandwidth

connector will indicate if it is single-mode. Otherwise it is a multi-mode port. Each 100Mbps

factory-built as either a multi-mode or single-mode SC connector. A yellow label on the fiber port

fixed 100Mb speed and full-duplex mode for the best performance. The P62’s fiber ports are

2.3 Fiber port, SC Connectors

GarrettCom Ethernet Switch (P62F) — 2.3 Fiber port, SC Connectors diagram (page 17)
Fig. 9 · 2.3 Fiber port, SC Connectors

While other switching technologies such as "cut-through" or "express" impose minimal

The Magnum P62-Series Hardened Switch is a store-and-forward switch. Each frame

The Fast Ethernet fiber switched ports on the Magnum P62-Series operate at

10Mb is not possible.

the LEDs are the same except there is no F/H LED because

and OFF for 10 Mbps (when LINK is made). For fiber ports,

transmitting / receiving. The 10/100 LED is ON for 100Mbps

LED is steady ON to indicate LINK, and blinking to indicate

duplex when ON or half-duplex when OFF. The (LK/ACT)

for each of the RJ-45 switched ports. The F/H indicates full-

There must be a device connected to the Magnum

On Magnum P62-Series units, there are three LED’s

Page 18 of the GarrettCom Ethernet Switch (P62F) user manual — 2.3 Fiber port, SC Connectors
Page 18 · click to enlarge
Page 18

is 5 microseconds plus the packet time at 100Mb.

is 15 microseconds plus the packet time at 10Mb. For 100Mb-to-100Mb forwarding, the latency

switches. For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the latency

speed types, and the length of the frame is a variable here, as it is with all store-and-forward

forwarded to its destination) of the P62-Series Hardened Ethernet Switch varies with the port-

incoming traffic.

entering by forcing a collision signal on all receiving RJ-45 half-duplex ports in order to stop

detects that its free buffer queue space is low, the Hardened Switch prevents more frames from

collision-based flow-control mechanism (when operating at half-duplex only). When the Switch

transparent to an observer. See Section 4.6 for additional details.

processing resumes. This flow-control sequence occurs in a small fraction of a second and is

allows a traffic catch-up to occur without dropping packets. Then, normal packet buffering and

cause “flow control”. This tells the sending devices to temporarily stop sending traffic, which

sends industry standard (full-duplex only) PAUSE packets out to the devices sending packets to

adapting internally to provide maximum network performance with the least dropped packets.

per port and in aggregate density, the Magnum P62-Series Hardened Switches are constantly

across the ports. Since the traffic on an operating network is constantly varying in packet density

P62-Series unit to be applied to all traffic loads, even when the traffic activity is unbalanced

This dynamic buffer allocation provides the capability for the maximum resources of the Magnum

number of packets to be stored per port. When the port buffer fills up, dropped packets result.)

have their packet buffer storage space divided evenly across all ports, resulting in a small, fixed

that heavily used ports receive very large buffer space for packet storage. (Many other switches

Series Hardened Switch dynamically allocates buffer space from an 1MB memory pool, ensuring

The latency (the time the frame spends in the Hardened Switch before it is sent along or

Another feature implemented in Magnum P62-Series Hardened Ethernet Switches is a

When the P62-Series Switch detects that its free buffer queue space is low, the Switch

To minimize the possibility of dropping frames on congested ports, each Magnum P62-

Page 19 of the GarrettCom Ethernet Switch (P62F) user manual — 2.5 Features and Benefits
Page 19 · click to enlarge
Page 19

2.5 Features and Benefits 100Mb switching services for high performance Ethernet LANs

MTBF over 10+ years, per Bellcore calculation method

Managed mP62’s with MNS(mP) software for Managed network

24VDC and -48VDC (Int.) & 125V/250VDC (ext.) through PSX-T

Thermal design enables P62S to be used in temp. uncontrolled applications.

Installation is “Plug n Play”, operation is transparent to software

Top-mounted LEDs for convenient viewing

All RJ-45 ports are auto-negotiating, support 10/100 full / half duplex

Two “future-proof” fiber ports with SC connectors

Email sales@garrettcom.com for MTBF detail.

QoS, STP, Port based VLAN, Port settings, Password security, BootP / DHCP etc

The New managed mp62 armed with management functions including SNMP,

reliable and convenient in out-of-the-way locations.

(int.) as well as 125V/250VDC through external PSX-T. DC power is highly

The P62-Series switch is designed to support 20-70 VDC auto-ranging power input

used as a heat sink, is designed specifically for uncontrolled applications.

The P62’s advanced thermal technique enclosed in rugged 18-gauge high steel

port connections or 10/100 domains without affecting operations.

other domains. Internal address tables are self-learning, enabling users to change

The Magnum P62-Series forward packets from each domain that are needed on the

top-surface viewing is most convenient.

in any situation. As the units are normally vertical for wall- or pedestal-mounting,

The LEDs that indicate operating status are on the top of the unit for easy viewing

half-duplex mode selected by Ethernet standard IEEE 802.3u

The auto-negotiating RJ-45 ports on P62-Series, with 10 or 100Mb speed and full /

full-duplex mode. No Media Converters needed.

mode SC, and (special order) SSCL-type connectors. The fiber ports are set to

Built-in fiber ports may be ordered with 100Mb full-duplex multi-mode SC, single-

segment a full 100Mb (or possibly 10 Mb for RJ-45 ports) of bandwidth.

perform high speed filter/forward operations on the traffic, giving each port’s

Magnum P62-Series Switches provide Fast Ethernet switching on all ports. They

Page 20 of the GarrettCom Ethernet Switch (P62F) user manual — 2.6 Applications
Page 20 · click to enlarge
Page 20

provides a Fast Ethernet fiber backbone for access to the central control station

Figure 2.6.1A P62F connects combinations of 10 Mbps and100Mbps network devices and

placed in a NEMA 4 enclosure to provide an all-weather outdoor solution.

of it cooling method. The mechanical design of the Magnum P62F also enables it to be easily

provide high bandwidth for fast movement of data. The advance design of sealed P62F takes care

temperature feature and high reliability of the P62F make it suited to the site.

make the required setup simple for collection of traffic data. The uncontrolled “outdoor”

serves this requirement economically and efficiently. The six full- and half-duplex switched ports

and some users and utility devices may run at 10 Mbps. A Magnum P62-Series Hardened Switch

other and to the central station. Some local users (using RJ-45 ports) may operate at 100Mbps,

Since multiple traffic control sites are long distances apart, they are all connected in series to each

roadside real time traffic data collection and transmits it to a remote control station over fiber.

Example 1. Magnum P62F In this example, a Magnum P62F Hardened Switch performs

future-proof fiber and widely-used copper connectivity to out-of-the-way sites.

2.6 Applications

GarrettCom Ethernet Switch (P62F) — 2.6 Applications diagram (page 20)
Fig. 10 · 2.6 Applications

The two 100Mbps full-duplex fiber ports easily fulfill the long distance connection and

The P62-Series is designed specifically for harsh temperature environments and brings

Page 21 of the GarrettCom Ethernet Switch (P62F) user manual — GARRE TT
Page 21 · click to enlarge
Page 21

cable more securely with the Switch ports.

cable strain feature gives extra protection and security to the cabling to hold the copper and fiber

solution for any temperature un-controlled location environments. The rugged enclosure with

enclosure and 20-70VDC power input qualifies the Magnum P62F to provide a dependable

providing a protected Ethernet network facility as part of the building infrastructure. The steel

building. The non-conductive fiber cabling inter-connects these switches through their fiber ports,

connectivity requirement in a harsh temperature environment, mounted above the ceiling in the

Figure 2.6.2Three P62F connects together to provide 10 Mbps and100Mbps network with

provide an exceptional Ethernet product.

the design (over 10+ years of MTBF) complements the temperature controlled packaging to

bandwidth for high performance. The ruggedness of the P62F steel case and the high reliability of

of 10 Mbps and 100Mbps users and devices. The switching capability on all ports provides

copper-cable user-access point. The 10/100 dual-speed functions to support a mixed environment

switching capability, the P62F provides a very economical high bandwidth solution at each

experiencing a need to scale its LAN quickly and cost effectively. With its half / full duplex

Example 2.

In this example, the extended temperature rated P62F takes care of the LAN

The Magnum P62F fits very well in high temperature locations (control rooms)

GarrettCom Ethernet Switch (P62F) — 2.6 Applications diagram (page 21)
Fig. 11 · 2.6 Applications

GARRE TT

Fast Ethernet backbone.

1 2 3 4 5 6

GARRE TT

Magnum P62F · 100 Server · Magnum P62F

Page 22 of the GarrettCom Ethernet Switch (P62F) user manual — PW
Page 22 · click to enlarge
Page 22

to deploy in harsh applications.

temperature applications and its wide variety of AC/DC options also qualify this hardened Switch

recovery and thus will improve the network reliability.

Spanning Tree Protocol efficiently control the ring topology environment with faster fault

solution in this particular kind of environment. The advanced Link-Loss-Learn feature along with

this requirement. The advanced Link-Loss-Learn feature will provide a very secure and effective

equipped with STP, VLAN, QoS etc features provide a very economical and efficient solution to

deployed in a ring topology application to fulfill the network requirement. The Managed mp62

network is 12Km.

interrupted by any faulty disconnect of any cabling. The area covered for this ring Topology

redundant network path in a ring topology so that all the important data mining should not be

be securely collect in a repository connected to the same Ethernet network, its best to develop a

Fig .2.6.3 The Magnum Managed mP62 in a ring topology application

Example 3. Magnum mP62

The managed mp62 Hardened Switch is specially designed to operate in uncontrollable

The managed mp62 loaded with MNS-mP software with its two fiber ports can be easily

T

T

In an uncontrolled temperature environment where the data mining needs to

T

GARRE

Magnum 1 3 5

PW

AC F/

F/ AC

10/1 L

2 TX T LK R L

AC F/

T

10/1 L

2 TX T LK R L

AC F/

AC F/

10/1 L

2 TX T LK R L

AC F/

F/ AC

AC F/

T

T

Show 10 more labels / short text on this page
Magnum · Magnum · Magnum · Swit · F/ AC Managed · Magnum Fiber · Magnum · Magnum · Magnum · Magnum
Page 23 of the GarrettCom Ethernet Switch (P62F) user manual — 3.0 INSTALLATION
Page 23 · click to enlarge
Page 23

and two bottom. The spacing for the mounting screws is a rectangle 3.35” x 7.92” (8.5cm x

vertical (cables at the bottom) position. The base plate of the unit has screw holes cut out, two top

3.1.2 Mounting dimensions

specifications. The mP62’s can be mounted on any material.

necessary to allow the thermal heat transfer from the case, achieving rated ambient temperature

select a sturdy place and carefully attach it to metal surface. Attaching P62F’s to a metal surface is

of its 18-gauge high-strength steel case enclosure. Because of its weight, it is very important to

P62F unit cannot be achieved if it is not properly mounted on metal.

to-metal contact with the mounting surface should be removed. The full temperature rating of the

position with appropriate screws. Rubber “feet” (if any) that would insulate the case from metal-

3.1.1 Mounting position and materials

visually monitor the status LEDs.

range of the unit. When installing the unit, be sure to maintain an open view of the top surface to

power (or any 20-70VDC three-wire (+, GND, -) power source for DC models) that is within the

AC power for convenience in out-of-the way locations. Locate the P62-Series unit near any AC

installations and military sites, the Magnum P62s support DC power input for high reliability and

facilities, on-board ships, cell towers, data communication huts and pedestals, aeronautical

commercial buildings, industrial boiler rooms, mines and quarries, irrigation and pipeline

control stations, unheated and or high temperatures locations, above-the-ceiling mounts in

models mounted vertically, attached to any wood or metal surface or in free air.

an equipment enclosure box) which does not exceed the ambient rating of the unit. Install mP62

that the metal case of the unit is in contact with a metal surface (such as a pedestal in the earth or

protect the P62-Series from accidental damage in any application setting. Install P62F models so

layout of the network. The rugged 18-gauge sheet steel case that acts as a heat sink will normally

3.1 Locating Magnum P62F-Series 10/100Mb Ethernet Switches

3.0 INSTALLATION

Each Magnum P62-Series Hardened Switch is normally mounted with screws in a

The Magnum P62-Series Hardened switches are quite heavy (3.5 lbs, 1.6 Kg) because

The Magnum P62-Series Hardened Switch should be securely mounted in a vertical

Designed primarily for specific applications such as roadside traffic data collection and

The location of a Magnum P62-Series Hardened Switch is dependent upon the physical

This chapter provides instructions for installing Magnum P62-Series units.

Page 24 of the GarrettCom Ethernet Switch (P62F) user manual — 3.35” (8.5)
Page 24 · click to enlarge
Page 24

information for the PSX unit (mounted on top, if present) and for the Magnum P62-Series unit.

mechanical drawings in Figures 1 & 2 below provide the mounting holes measurement

plate to the vertical mounting surface. The PSX Power Source mounting is similar. The

20.1cm) center-to-center. Four user-supplied screws, ¼” max diameter, attach the P62’S base

Fig 1.

Mounting Hole Dimensions, inches & (cm)

3.35” (8.5)

3. 35” (8.5)

3. 35” (8.5)

3.35” (8.5)

7. 92” (20.1)

6.13” (15.68)

Page 25 of the GarrettCom Ethernet Switch (P62F) user manual — 3.2 Connecting Ethernet Media, and Special Strain-relief feature
Page 25 · click to enlarge
Page 25

3.2.1 Connect Twist Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shield)

NOTE 1. : It is recommended that high quality CAT. 5 cables (which work for both 10 Mbps and 100Mbps) be used whenever possible in order to provide flexibility in a mixed- speed network, since P80-series switch ports are auto-sensing for either 10 and 100Mbps. Note that the auto-sensing function does not sense the cable type. NOTE 2. It is recommended that to fulfill the requirement of UL2043 smoke tests, the cable (RJ- 45, Fiber, AC/DC power cable) provided by the user must be rated as UL2043 Compliant, for use in air handling and above-the-ceiling spaces.

cabling supports much longer cable distances and higher bandwidth than copper wiring.

cabling can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber

3.2 Connecting Ethernet Media, and Special Strain-relief feature

GarrettCom Ethernet Switch (P62F) — 3.2 Connecting Ethernet Media, and Special Strain-relief feature diagram (page 25)
Fig. 12 · 3.2 Connecting Ethernet Media, and Special Strain-re…

Media IEEE Standard Connector Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45 Twisted Pair (CAT 5) 100BASE-TX RJ-45 Fiber (Multi-mode) 100BASE-FX SC Fiber (Single-mode) 100BASE-FX SC

and shielded twisted pair cables.

twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded

The following procedure describes how to connect a 10BASE-T or 100BASE-TX

The Magnum P62-Series Ethernet Switches (P62F model illustrated here) can be

mode, 50/125 or 62.5/125 microns

fiber port 100BASE-FX multi-

cabling is 100 meters (328 ft). For

distance for unshielded twisted pair

used. In either case, the maximum

10BASE-T ports, CAT 3 may be

When the ports are used as

making 100BASE-TX connections.

CAT 5 cables should be used when

10BASE-T and 100BASE-FX.

media types100BASE-TX,

connected to the following three

Page 26 of the GarrettCom Ethernet Switch (P62F) user manual — 3.2.2 Connecting Fiber Optic SC-type, "Snap-In"
Page 26 · click to enlarge
Page 26

core and the core plus the cladding respectively). Single-mode fiber allows full bandwidth at

single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the

Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125 microns for

3.2.4 Connecting Single-Mode Fiber Optic

3.2.2 Connecting Fiber Optic SC-type, "Snap-In" The following procedure applies to installations using SC-type fiber connectors. This procedure applies to ports using multi-mode SC fiber connectors. 1. Before connecting the fiber optic cable, remove the protective dust cap / plug from the end of the fiber connectors, exposing the ports opening. Save the dust cover / plug for future use, in case the fiber cable needs to be unplugged for service. 2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue dampened in alcohol. Make certain the connectors are clean before connecting. Then, insert the square male connector into the SC female jack of the Fiber port connector until it clicks and secures. Note: One strand of the duplex fiber optic cable may be coded using color bands at regular intervals; you should use the color-coded strand on the associated ports at each end of the fiber optic cable segment. 3. Connect the Transmit (TX) port on the Magnum Fiber port to the Receive (RX) port of the remote device. Begin with the color-coded strand of the cable for this first TX-to-RX connection. Note – the two male square-end SC cable strands may be fastened together to plug as a unit. 4. Connect the Receive (RX) port to the Transmit (TX) port of the remote device. Use the non-color coded fiber strand for this. 5. The LINK LED for the fiber connector will illuminate when a proper connection has been established at both ends (and when power is ON in the unit). If LINK is not lit after cable connection, the normal cause is improper cable polarity. Swap the fiber cables at the fiber connector to remedy this situation. 3.2.3 Connecting Fiber Optic ST-type, “Snap-In” (Optional)

connectors into the ST female jacks of the Fiber connector until it clicks and secures.

multi-mode ST.

1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used. 2. Connect the other end of the cable to the corresponding device. 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established. If this does not help, ensure that the cable is connected properly and that the device on the other end is powered and is not defective. 4. For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which has a cross-over or up-link for linking to another hub or Switch.

When connecting fiber media to ST connectors, simply twist on the two round male

The following procedure applies to installations using ST-type fiber connectors, i.e., using

When using single-mode fiber cable, be sure to use single-mode fiber port connectors.

Page 27 of the GarrettCom Ethernet Switch (P62F) user manual — 3.2.5 Power Budget Calculations for P62-Series Fiber Media
Page 27 · click to enlarge
Page 27
  • * Not e: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following factors are both applied:
  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, and
  • The worst-case OPB of the fiber link must be greater than the fiber cable’s passive Attenuation. (Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
GarrettCom Ethernet Switch (P62F) — 3.2.5 Power Budget Calculations for P62-Series Fiber Media diagram (page 27)
Fig. 13 · 3.2.5 Power Budget Calculations for P62-Series Fiber…

The following data has been collected from component manufacturer’s (HP’s and Siemens’) web sites and catalogs to provide guidance to network designers and installers.

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km, and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using Magnum products, the following equations should be used: OPB (Optical Power Budget) = PT(min) - PR(min) where PT = Transmitter Output Power, and PR = Receiver Sensitivity

3.2.5 Power Budget Calculations for P62-Series Fiber Media

Follow the steps listed in Section 3.2.2 above.

longer distances, about 20Km with the single-mode SC.

The same procedures as for multi-mode fiber apply to single-mode fiber connectors.

40 (0.4) 1300 9/125 -5 -34 27 54 32.5 65

20 (0.4) 1300 9/125 -15 -31 14 28 17.5 35

Page 28 of the GarrettCom Ethernet Switch (P62F) user manual — 3.2.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports
Page 28 · click to enlarge
Page 28

P62 -48V, 24VDC INSTALLATION This section describes the proper connection of the -48VDC leads (or 24VDC leads) to the DC power terminal block on the Magnum P62 Switch (as shown in Figure above) The DC terminal block on the Magnum P62-Series Hardened Switch is located on the left front of the unit and is equipped with three (3) screw-down lead posts. The power terminals are identified as positive (+) and negative (-), and they are floating inside the unit so that either may be grounded by the user if desired. The chassis is “earth” or ground (GND). The connection procedure is straightforward. Simply insert the DC leads to the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely tightened. NOTE: Always use a voltmeter to measure the voltage of the incoming power supply and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead will connect to the post labeled “+ve” and the rest to the “-ve”. The GND can be hooked up at the last. When power is applied, the green PWR LED will illuminate.

Power Consumption10 watts typical

DC Power Terminals: “+”, “-”, internally floating GND: Terminal for “earth” or ground wire connection to the P62 chassis Input Voltage: 20 to 70 VDC Input current: 0.7 amp max.

3.3.1 Power P62F and mP62 models, for –48V and 24V DC pwr input Each Magnum Model P62-Series Hardened Switch requires a DC power source, from 20- 70VDC. The wide range of power input qualifies this product for use both in 24VDC as well as - 48VDC environments. The 24VDC or -48VDC power input provides an Ethernet networking product utilizing a special type of power supply with a proven high-reliability record.

3.3 Powering the Magnum P62-Series Hardened Switch

the 10/100 LED is steady ON. It is OFF if there is no traffic or if 10 Mbps traffic.

protocol other than 100BASE-TX (such as 10BASE-T). When 100Mb speed is agreed and in use,

necessary to reload the NIC drivers on the user device if the NIC has been communicating with a

coding for the 100BASE-TX signaling system. When connecting a NIC to a P62, it may be

NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse (FLP)

3.2.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports

The copper ports of Magnum P62-Series Hardened Switches will function properly with

GarrettCom Ethernet Switch (P62F) — 3.2.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports diagram (page 28)
Fig. 14 · 3.2.6 Connections to NICs which support Auto-Negotia…
Page 29 of the GarrettCom Ethernet Switch (P62F) user manual — 3.3.2 Power the P62-5V models w/Ext AC Power Supply (PSX-A)
Page 29 · click to enlarge
Page 29

through a separate Power Source unit, the PSX-T. The wide range of AC power input qualifies

3.3.3 Power the P62-5V w/DC Pwr Supply (PSX-T) at 125/250 VDC

Operating Shock and Vibrationmeets Bellcore GR-63-CORE Sections 4.4.1 and 4.4.3

Surge Protection: over 150 joules, with clamping at 800V 50A min.

Power Capacity15 watts output, 70% min efficiency

Input Fuse for overload and short protection: 3AG type, 0.5 Amp; spare is included

Power Output5VDC, 3Amps max

AC Power Connector: IEC-type, male recessed Wiring Pin out (P62F-5V) Power Adaptor: Pin 1 +ve voltage (white wire in the cable) Pin 2 -ve voltage (black wire in the cable) Pin 3 chassis ground (green wire in the cable) Pin 4 not used

Input Voltage85-264 VAC, 4763HZ, Auto-ranging

female plug for secure attachment to the P62-5V Switch.

side boxes for traffic control. The DC power output cord comes with a military-style screw-lock

strikes. Shock and vibration characteristics enable use in transportation applications such as road-

surge protection to withstand AC power input upsets, such as might result from nearby lightening

sink, enabling extended application temperatures to be accommodated. The PSX-A also includes

source (PSX-A) provides a rugged power supply enclosed in a metal case that also acts as a heat

qualifies this product for use worldwide, in almost any temperature environment. The AC power

50-60Hz through a separate Power Source unit, the PSX-A. The wide range of AC power input

applications at extended temperatures, also supports universal AC power input from 85-275 vac

3.3.2 Power the P62-5V models w/Ext AC Power Supply (PSX-A)

The rugged Magnum P62-5V Hardened Switch also supports 125V/250 VDC power

The rugged Magnum P62-5V Hardened Switch, mainly used in “outdoor” Ethernet

GarrettCom Ethernet Switch (P62F) — 3.3.2 Power the P62-5V models w/Ext AC Power Supply (PSX-A) diagram (page 29)
Fig. 15 · 3.3.2 Power the P62-5V models w/Ext AC Power Supply…
Page 30 of the GarrettCom Ethernet Switch (P62F) user manual — 3.3.2 Power the P62-5V models w/Ext AC Power Supply (PSX-A)
Page 30 · click to enlarge
Page 30

PSX-T INSTALLATION This section describes the proper connection of the -125V/250 VDC leads to the – 125/250 VDC power terminal block on the PSX-T Power Source (as shown in Figure above) The –125/250 VDC terminal block on the External PSX-T is located on the left side of the unit and is equipped with three (3) screw-down lead posts, covered by a removable safety shield or cover. The power terminals are identified as positive (+) and negative (-), and they are floating inside the unit so that either may be grounded by the user. The chassis is “earth” or ground (GND). The connection procedure is straightforward. Simply insert the DC leads to the PSX-T’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it connects to the PSX-T chassis. Ensure that each lead is securely tightened, then replace safety shield. When power is applied, the green PWR LED will illuminate

Vibrationmeets Bellcore GR-63-CORE Sections 4.4.1 and 4.4.3

output, 70% min efficiency

Power Capacity15 watts

DC Power Terminals: “+”, “-”, internally floating GND terminal for “earth” or ground wire connection to the PSX-T chassis Input Voltage: 100 to 275VDC Power Output : 5VDC, 3Amps Input Fuse: 3AG type, 0.5 Amp; spare is included

to the P62-5V Hardened Switch.

DC power output cord comes with a military-style screw-lock female plug for secure attachment

polarity protection to prevent damage in case the unit is accidentally hooked up backwards. The

sink, enabling extended temperatures to be accommodated. The PSX-T also includes reverse-

source (PSX-T) provides a rugged power supply enclosed in a metal case that also acts as a heat

this product for use worldwide, in almost any temperature environment. The 125/250 VDC power

GarrettCom Ethernet Switch (P62F) — 3.3.2 Power the P62-5V models w/Ext AC Power Supply (PSX-A) diagram (page 30)
Fig. 16 · 3.3.2 Power the P62-5V models w/Ext AC Power Supply…

Operating Shock and

Page 31 of the GarrettCom Ethernet Switch (P62F) user manual — 3.4 Cable Strain Relief Feature on all P62-Series models
Page 31 · click to enlarge
Page 31

operation.

connection from coming loose. This feature provides a more reliable and robust installation and

event that the attached cable is pulled, the tie-wrap cable strain relief feature protects the cable

cables and can be attached to the base plate HOOK provided at the bottom-front of the unit. In the

well as to Ethernet cables, both twisted-pair copper and fiber. Cable tie-wraps can secure the

plate of the unit for cable strain relief. The strain-relief feature is applicable to power cables as

provided as part of the package design

mounted vertically so that the cables hang out the bottom. There is a cable strain relief feature

and control stations, above-the-ceiling locations in commercial buildings, etc. They are usually

temperature environments, which qualifying them to be used in roadside traffic data collection

3.4 Cable Strain Relief Feature on all P62-Series models

The figure below of a P62F model illustrates the strain-relief feature, using tie-wraps.

The Magnum P62-Series Hardened Switches have a tie wrap holder as part of the base

The Magnum P62-Series Hardened Switches are designed to use in extended

GarrettCom Ethernet Switch (P62F) — 3.4 Cable Strain Relief Feature on all P62-Series models diagram (page 31)
Fig. 17 · 3.4 Cable Strain Relief Feature on all P62-Series mo…
Page 32 of the GarrettCom Ethernet Switch (P62F) user manual — 4.0 OPERATION
Page 32 · click to enlarge
Page 32

locations.

removed or moved from one segment to another, the P62-Series automatically keeps up with node

are suitable for use in large networks. They are self-learning, so that as nodes are added or

heavy traffic on the network.

mode, which eliminates bad packets and enables peak performance to be achieved when there is

packets) are forwarded to all ports.

Packets needed for maintaining the operation of the network (such as occasional multi-cast

forwarded to the appropriate port, and will not be sent to the other ports where it is not needed.

processing them. A packet whose destination address is on another port segment will be

segment will be filtered, constraining them to one port and relieving the rest of the network from

filter or to forward the packet. Packets whose source and destination addresses on the same port

Switching, Filtering and Forwarding

attached with these ports. The internal functions of P62-Series Switch is described below.

45 ports is user dependent and changes (by auto-negotiation) to full or half duplex as the unit

be done at installation or for maintenance. The Half / full duplex mode for the RJ-45 switched RJ-

100Mbps Ethernet, and can communicate with 10Mb domain too.

100Mbps users as well as 100Mbps domain. Similarly, the 100Mbps traffic obeys the rules of

configurations. The 10 Mbps users share a 10 Mbps traffic domain, and can “communicate with”

2.2). When the connected device is 10 Mbps, P62s obey all the rules of 10 Mbps Ethernet

auto-negotiation capability.

with two built-in full-duplex “future-proof” fiber ports. The six RJ-45 copper ports equipped with

ports, and two 100Mb fiber ports. The architecture supports a dual speed switching environment,

4.1 Dual-Speed Functionality, and Switching

4.0 OPERATION

The Magnum P62-Series units have an address table capacity of 4K node addresses, and

The Magnum P62-Series Hardened Switch operate in the store-and-forward switching

Each time a packet arrives on one of the switched ports, the decision is taken to either

All Magnum P62 units are plug-and-play devices. There is no software configuration to

The switched RJ-45 ports are full / half duplex and auto-sensing for speed. (See section

This section describes the function and operation of the Magnum P62-Series Switches.

The Magnum P62-Series Hardened Switch provide six 10/100 RJ-45 switched

Switching, Address Learning

Page 33 of the GarrettCom Ethernet Switch (P62F) user manual — 4.2 Auto-negotiation and Speed-sensing
Page 33 · click to enlarge
Page 33

4.3 LED’s for P62-Series Hardened Switch POWER: Illuminates GREEN, steady on when power applied. SELF TEST: Indicates the self-test at power up was not successful. F/H: ON = Full-Duplex and Link, OFF = Half-Duplex and / or no Link. LK/ACT: Per port, steady ON for LINK with no traffic, blinking indicates port is transmitting and receiving. 10/100: Per port, ON = 100Mbps; OFF = 10 Mbps (when LINK is made).

half-duplex mode, per the IEEE 802.3u standard).

P62s RJ-45port is connected to a non-negotiating device, it will default to 10 Mbps speed and

ON indicates the port is transmitting / receiving. The port has auto-negotiated for operation. (If a

agreement to operate at either 10 Mbps or 100Mbps speed.

agree to the speed being used. Depending upon the device connected, this will result in

the device at the other end of the cable should similarly advertise / respond and both sides will

negotiation takes place. The P62-Series advertises its capability for 10 or 100 Mbps speed, and

100BASE-TX modes. Operation is according to the IEEE 802.3u standard.

4.2 Auto-negotiation and Speed-sensing

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

When the ‘LK/ACT’ LED is ON, steady ON indicates LINK with no traffic, blinking

When a RJ-45 cable connection is made, and each time a LINK is enabled, auto-

All six RJ-45 ports independently support auto-negotiation for speed in 10BASE-T and

An address-aging algorithm causes least-used addresses to fall out in favor of new

GarrettCom Ethernet Switch (P62F) — 4.2 Auto-negotiation and Speed-sensing diagram (page 33)
Fig. 18 · 4.2 Auto-negotiation and Speed-sensing
Page 34 of the GarrettCom Ethernet Switch (P62F) user manual — 5.0 TROUBLESHOOTING
Page 34 · click to enlarge
Page 34
5. If the problem continues after completing Step 4 above, contact your supplier of the
4. If the problem is isolated to a network device other than the Magnum P62-Series
3. Make sure that an AC power cord is properly attached to each Magnum P62-Series
2. Check the cables and connectors to ensure that they have been properly connected and
1. If difficulty is encountered when installing or operating the unit, refer back to the

Customer Support. 5.1 Before Calling for Assistance

not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom

in this section or if the Magnum P62-Series Hardened Switch is not performing as expected, do

below prior to contacting your supplier. However, if you are unsure of the procedures described

help locate, identify and correct these types of problems. Please follow the suggestions listed

straightforward and is discussed in Section 4.

is a straightforward procedure (see INSTALLATION, Section 3); the operation is also

performance in all network environments. The installation Magnum P62-Series Hardened Switch

5.0 TROUBLESHOOTING

fax, phone or email (support@garrettcom.com) for assistance.

Magnum P62-Series Hardened Switch unit or if unknown, contact GarrettCom, Inc. by

associated cables are functioning properly.

5 below. If the problem is corrected, the Magnum P62-Series Hardened Switch and its

known good device. Verify whether or not the problem is corrected. If not, go to Step

Hardened Switch product, it is recommended that the problem device is replaced with a

functioning electrical outlet. Use the PWR LEDs to verify each unit is receiving power.

Hardened Switch unit. Be certain that each AC power cord is plugged into a

(About 90% of network downtime can be attributed to wiring and connector problems.)

the cables/wires have not been crimped or in some way impaired during installation.

that the various components of the network are interoperable.

Installation Section of the applicable chapter of this manual. Also check to make sure

Should problems develop during installation or operation, this section is intended to

All Magnum Ethernet products are designed to provide reliability and consistently high

Page 35 of the GarrettCom Ethernet Switch (P62F) user manual — 5.2 When Calling for Assistance
Page 35 · click to enlarge
Page 35

please have the following information readily available:

9071 during business hours in California or email to support@garrettcom.com. When calling,

(RMA) number. To obtain an RMA number, call GarrettCom Customer Service at (510) 438-

5.3 Return Material Authorization (RMA) Procedure

5.2 When Calling for Assistance

to the occurrence of the problem. Any changes to system administration

4. A record of changes that have been made to your network configuration prior
3. It is useful to include other network equipment models and related hardware, including
2. An accurate list of GarrettCom product model(s)involved, with serial number(s).
1. A complete description of the problem, including the following points:

Failure symptoms, including a full description of the problem.

Packing List Number (or Sales Order Number)

Serial Number (or Invoice Number)

Name of your company / institution

Name and phone number of your contact person.

All returns for repair must be accompanied by a Return Material Authorization

procedures should all be noted in this record.

media types being used.

personal computers, workstations, terminals and printers; plus, the various network

Include the date(s) that you purchased the products from your supplier.

d. Any particular application that, when used, appears to create the problem;

c. The components involved in the problem;

b. Situations when the problem occurs;

a. The nature and duration of the problem;

Please be prepared to provide the following information.

Date of installation · Product name · Your shipping address

Page 36 of the GarrettCom Ethernet Switch (P62F) user manual — 5.4 Shipping and Packaging Information
Page 36 · click to enlarge
Page 36

Attn.: Customer Service APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom. This warranty will not be effective if, in the opinion of GarrettCom, the product has been damaged by misuse, misapplication, or as a result of service or modification other than by GarrettCom. GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty.

GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if the problem or condition causing the return cannot be duplicated by GarrettCom, the unit will be returned as: No Problem Found. GarrettCom reserves the right to charge for the testing of non-defective units under warranty. Testing and repair of product that is not under warranty will result in a customer (user) charge. 5.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection. ( You may retain all connectors and this Installation Guide.) CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static shock damage to the unit.

and mail it to GarrettCom within two weeks of your purchase.

Please complete the warranty card as this acts as a product registration

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container. 3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to:

213 Hammond Ave.

GarrettCom, Inc.

Fremont, CA 94539

Ask about the GarrettCom Ethernet Switch (P62F)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom Ethernet Switch (P62F)

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom Ethernet Switch (P62F) manual PDF

36 pages·563 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…