EN
GarrettCom logo
Official user manual

GarrettCom FT14

63 pages·410 KB·Welding System·PDF·ENDEFRITNLJA
GarrettCom FT14
Table of Contents 34 sections Revisions · 1.0 SPECIFICATIONS · 1.1 Technical Specifications · 1.2 Summary of models and descriptions: · … ShowHide
Page 1 of the GarrettCom FT14 user manual — MagnumFT14 and FT14H
Page 1 · click to enlarge
Page 1

MagnumFT14 and FT14H

10Mb/s Media Converters Installation and User Guide

GarrettCom FT14 — MagnumFT14 and FT14H diagram (page 1)
Fig. 1 · MagnumFT14 and FT14H
GarrettCom FT14 — MagnumFT14 and FT14H diagram (page 1)
Fig. 2 · MagnumFT14 and FT14H
Websitehttp://www.GarrettCom.com

email support@garrettcom.com

47823 Westinghouse Dr. Fremont, CA 94539

GarrettCom, Inc.

ww m com w GarrettCo. .

Corporate Headquarters · Phone (510) 438-9071 · Fax (510) 438-9072

Page 2 of the GarrettCom FT14 user manual — Installation and User Guide
Page 2 · click to enlarge
Page 2

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

Magnum ™ FT14 and FT14H 10Mb/s Media Converters

experienced with Magnum FT14/FT14H 10 Mb/s Media Converters products,

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a

contains no user serviceable parts. Attempted service by unauthorized

personnel shall render all warranties null and void. If problems are

of this publication may be reproduced without prior written permission from

Installation and User Guide

consult Section 5, Troubleshooting, of this User Guide.

Copyright © 2003 GarrettCom, Inc. All rights reserved. No part

Part #84-00134 Rev. A (09/04)

UL is a registered trademark of Underwriters Laboratories

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

registered trademark of GarrettCom, Inc.

Printed in the United States of America.

GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom FT14 user manual
Page 3 · click to enlarge
Page 3

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and

found to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user at his own expense will be required to take whatever

Radio Frequency Interference Statement

measures may be required to correct the interference.

Federal Communications Commission

Page 4 of the GarrettCom FT14 user manual — Phone (510) 438-9071
Page 4 · click to enlarge
Page 4

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

Please use the mailing address, phone and fax numbers and email address listed below:

Websitehttp://www.GarrettCom.com
Emailsupport@ garrettcom.com

47823 Westinghouse Dr. Fremont, CA 94539

GarrettCom, Inc.

Phone (510) 438-9071

Fax (510) 438-9072 · Contacting GarrettCom, Inc

Page 6 of the GarrettCom FT14 user manual — 4.4 Dual LEDs, front-panel and side-panel (Magnum FT14/FT14H) ... 45
Page 6 · click to enlarge
Page 6

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

3.6 Connecting Ethernet Media 34

3.6.1 Connecting Twisted Pair (RJ-45 ports)...................................... 34

3.6.2 Connecting Fiber Optic mm, sm (halfand full-duplex) ......... 35

3.6.3 Power Budget Calcs for Fiber Media Magnum FT14-serie s ...... 37

4.0 OPERATION ....................................................................................... 39

4.1 Power Requirements, Power Supply Types for FT14 and FT14H .... 39

4.2 Powering the FT14H (DC Direct) power input 41 4.3 FT14H, DC-powered, Installation 43

4.4 Dual LEDs, front-panel and side-panel (Magnum FT14/FT14H) ... 45

4.5 Up-Link (Cross-over) Switch ............................................................ 46

5.0 TROUBLESHOOTING ...................................................................... 47

5.1 Before Calling for Assistance ............................................................ 48

5.2 When Calling for Assistance ............................................................. 50

5.3 Return Material Authorization (RMA) Procedure............................. 51

5.4 Shipping and Packaging Information................................................. 54

APPENDIX A: WARRANTY INFORMATION......................................... 55

Page 7 of the GarrettCom FT14 user manual — Revisions
Page 7 · click to enlarge
Page 7

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or

Rev A 06/04Minor updates on Agency approvals and power supplies
Rev A 05/03Initial release of this user manual for FT14 and FT14H
Rev A 09/04Minor updates on UL Requirements, power supplies

model offerings without notice.

Revisions

Page 8 of the GarrettCom FT14 user manual — 1.0 SPECIFICATIONS
Page 8 · click to enlarge
Page 8

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

EthernetEthernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE-FL IEEE

(Magnum Media Converters are physical layer standard Ethernet products,

Experience shows that up to three units can be used in series between repeaters.

For 4 or more in series, noise build-up will typically preclude proper operation.

Model FT14, FT14H multi-mode and single-mode

Data Rate10 Mbps (IEEE 802.3), half duplex mode

and operate independently of all software.)

Number of Media Converters in series:

1.1 Technical Specifications

1.0 SPECIFICATIONS

Network Standards:

Performance:

802.3,

Page 9 of the GarrettCom FT14 user manual — Operating Environment:
Page 9 · click to enlarge
Page 9

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

Ambient Temperature(0 º C to 50 º C) FT14-Hd,-Hi, FT14S-Hd, Hi

(-40ºC to 55ºC) FT14H-Hd,-Hi, FT14SH-Hd,Hi

FT14H-24VDC, FT14SH-24VDC

(-40ºC to 75ºC) FT14H-9VDC, FT14SH-9VDC,

FT14H-48VDC, FT14SH-48VDC

Section 3.2 of this manual for media lengths and segment distance calculations.

10BASE-FL Single-mode Fiber optic10.0 km (32,810ft)
10BASE-FL Fiber optic2.0 km (6,562 ft)
10BASE-T (twisted pair)100 m (328 ft)
Storage Temperature-40 º C to 100 º C (-40 º F to 212 º F)

Maximum Standard Ethernet Segment Lengths:

Cold start down to -25ºC

Operating Environment:

Page 10 of the GarrettCom FT14 user manual — Power Supply
Page 10 · click to enlarge
Page 10

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

rated output voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current

(i.e. 100mA to 500mA).When connected to a 48 V centralized dc source these products

Designed for NEBS compliance, including vibration, shock, and altitude

marked “Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably

UL 2043 tested for above-the –ceiling (plenum) installation

These products are intended to be supplied by a Listed, Direct Plug-In power unit,

100-240V AC at 50-60Hz, for “-Hd” high temp. with built-in IEC320 connector Power input 9V DC jack is 2.5mm center +ve jack, with 6ft. cord

Ambient Relative Humidity5% to 95% (non-condensing)

Conformal coating (humidity protection) option, request quote.

shall be provided with a Listed 5 A DC fuse in the supply circuit.

UL listed Class II Power Supply ( AC-DC Adapter):

“Hd” North American models

Power Supply

Page 11 of the GarrettCom FT14 user manual — 1.0 SPECIFICATIONS
Page 11 · click to enlarge
Page 11
Power Consumption1.5 watts typical and 2 watts max. for all models

24V DC internal (range of 18 to 36V DC)

GarrettCom FT14 — 1.0 SPECIFICATIONS diagram (page 11)
Fig. 3
GarrettCom FT14 — 1.0 SPECIFICATIONS diagram (page 11)
Fig. 4

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

GarrettCom FT14 — 1.0 SPECIFICATIONS diagram (page 11)
Fig. 5

100-240V AC at 50-60Hz, for high temp. with built-in IEC320 connector for “-Hi” DC to unit:

block for +, -, ground. The 9V DC jack is also present.

Power Supply ( DC Direct)built-in terminal

-48V DC internal (range of 36 to 60V DC)

9V DC, 2.5mm jack, center +ve, 6ft. cord

9V DC internal (range of 7.5 to 15V DC)

Connectors, for Media:

“Hi” international model

Page 12 of the GarrettCom FT14 user manual — Packaging:
Page 12 · click to enlarge
Page 12

LED FT14 FT14S Description

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

FT14 and FT14H: 3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm)

Cooling MethodConvection, plus the case is used as a heat sink on “H” models

segments are operational at the other end

Link(per port) TP, Fiber TP, Fiber * Steady ON when both attached cable

Weightall FT14 and FT14H mm and sgl.mode models: 4.6 oz. (130g);
Dimensions, Media Converter unitHeight x Width x Depth

RX/Act TP, Fiber TP, Fiber Indicates port is receiving packets.

RJ-45 PortModular 8-Pin female, with “cross-over” up-link switch

PWR unit unit Steady ON when power applied.

Fiber PortFiber optic (standard ST type)
power supply –Hd, and =Hi3 oz (85g)

Enclosure: Rugged sheet metal (Steel).

Media Converter LED Indicators:

Packaging:

Page 13 of the GarrettCom FT14 user manual — 1.0 SPECIFICATIONS
Page 13 · click to enlarge
Page 13

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

Rack-mount optionMC14-TRAY, see http://www.garrettcom.com/mc_tray.htm

Mean Tine Between Failure (MTBF) – 15+ years, Telcordia (Bellcore) Method

WarrantyThree years, return to factory Made in USA

UL LISTED (UL 60950), CUL, CE Emissions meet FCC Part 15, Class A

IEC61850 EMC and Operating Conditions Class C for Power Substations

H ModelIEEE P1613 Env. Std for Electric Power Substations
DIN-Rail mounting optionModel # DIN-RAIL MC2 (see Section 3.4)
H ModelNEMA TS-2 and TEES for traffic control equipment
H Modeldesigned for UL 2043 above-the-ceiling installation

Metal Mounting clips for panel mounting: included

Agency Approvals and Standard Compliance:

NEBS L3 and ETSI compliant

Page 14 of the GarrettCom FT14 user manual — 1.2 Summary of models and descriptions:
Page 14 · click to enlarge
Page 14

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

FT14HR-24V DC = TP to mm Fiber, 24V DC Internal pwr supply, -40 to 75`C, includes DIN-Rail

FT14H-Hd = TP to 10Mb mm Fiber ST, external 115 60Hz AC power supply, for -40 to 55`C

FT14H-Hi = TP to 10Mb mm Fiber ST, external 230 50Hz AC power supply, for -40 to 55`C

For a Single-mode 10Mb Fiber ST model, insert “S” after the number “14” in each line above.

DIN-RAIL-MC2 Metal DIN-Rail mounting bracket for one FT14-Series

FT14-Hd = TP to 10Mb mm Fiber ST, external 115 60Hz AC power supply, for 0 to 50`C

FT14-Hi = TP to 10Mb mm Fiber ST, external 230 50Hz AC power supply, for 0 to 50`C

FT14H-9V DC = TP to 10Mb mm Fiber ST, 12V DC Internal power supply, -40 to 75`C

FT14H-24V DC = TP to 10Mb mm Fiber ST, 24V DC Internal power supply, -40 to 75`C

FT14H-48V DC = TP to 10Mb mm Fiber ST, 24V DC Internal power supply, -40 to 75`C

MC14-TRAY = 19” Rack-mount tray for 14-series Media Converters, up to 16 units

1.2 Summary of models and descriptions:

Media Converter .

Page 15 of the GarrettCom FT14 user manual — 2.0 INTRODUCTION
Page 15 · click to enlarge
Page 15

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

1 Magnum FT14 or FT14H mm or single-mode Media Converter Unit

1 External Power Supply, (except for internal DC power supply models)

1 User Guide, i.e., this manual (continued next page)

This section describes the FT14 and FT14H models, including appearance,

2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this

product; notify the carrier immediately of any damage which you believe occurred

during shipment or delivery. Inspect the contents of this package for any signs of

1 set Metal panel mounting clips and screws, 2 each

damage and ensure that the items listed below are included.

2.0 INTRODUCTION

features and typical applications.

This package should contain:

Page 16 of the GarrettCom FT14 user manual — 2.2 Product Description
Page 16 · click to enlarge
Page 16

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

offer a graceful way to convert and transmit data between twisted pair and Fiber network

Remove the Magnum Media Converter from the shipping container. Be sure to keep the

return the unit use the original shipping container. Refer to Section 5 Troubleshooting,

2.2 Product Description Rugged packaging, a selection of extended temperature models, choice of AC

In the event there are items missing or damaged contact your supplier. If you need to

characteristics of the Magnum 10Mb FT14 and FT14H Media Converters. All models

specifications and the IEEE 802.3 standards. Power consumed in use is 1.5 to 2 watts.

cables for media flexibility in new or expanded 10Mb Ethernet networks. The future

proof fiber comes as ST connector with Multi or Single Mode options. They provide

standard collision detection and indication, and comply with the Ethernet V1.0 / 2.0

and DC power types, ease-of-use features, and energy-efficiency are the primary

shipping container should you need to ship the unit at a later date.

for specific return procedures.

Page 17 of the GarrettCom FT14 user manual — FIBER COPPER
Page 17 · click to enlarge
Page 17

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

and use an external AC power supply. A metal case with convection cooling is featured.

The FT14 regular-package units are for office and wiring closet environments

GarrettCom FT14 — 2.2 Product Description diagram (page 17)
Fig. 6 · 2.2 Product Description

Magnum FT14 Magnum FT14H

TX

R

GarrettCom

LINK LINK RX/ACT

onverte 10Mb/s Media C r

9VDC .0.3AMP Magnum FT14

FIBER COPPER

PWR

R

X/

A

T

Ethernet at its · 10 Mb/s · Best

Page 18 of the GarrettCom FT14 user manual — 2.2 Product Description
Page 18 · click to enlarge
Page 18

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

Operation may be in 0° to 50°C ambient temperature. The units can be mounted securely

heat sink. No air inflow is required for cooling, so the FT14H resists dust, dirt, moisture,

on a closet wall or metal cabinet, or by using the metal panel mounting clips included.

The FT14H Hardened unit features a sealed metal case which is also used as a

DC power are available. Storage temperature rating is up to –40°C to +75°C depending

on the power source used. The FT14H is suitable for temperature un-controlled outdoor

environments. FT14 Media Converters cost significantly less than full repeaters and can

smoke and insects, and is plenum rated. Choices of models for external AC or internal

applications. Mounting options include panel-mounting, DIN-rail, or rack-mount tray.

transmit data among twisted pair, and Fiber (Multi or Single Mode) network cabling

be used whenever media distance limitations will not be exceeded in the segment.

The FT14-series Media Converters offer a graceful way to convert and

Page 19 of the GarrettCom FT14 user manual — 9VDC
Page 19 · click to enlarge
Page 19

T)

Twisted Pair ( 10BASE-

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

All units are compatible with Ethernet V 1.0 / 2.0 specifications and comply with IEEE

GarrettCom FT14 — T) diagram (page 19)
Fig. 7

TX

R

GarrettCom

onverte 10Mb/s Media C r

LINK LINK RX/ACT PWR

Best Ethernet at its

FIBER COPPER

R

X/

A

T

802.3 standards.

9VDC

Magnum FT14 · 10 Mb/s

Page 20 of the GarrettCom FT14 user manual — 2.2 Product Description
Page 20 · click to enlarge
Page 20

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

The up-link (or crossover) switch on the RJ-45 port simplifies cable installation. All fiber

Magnum FT14-series 10Mb Media Converters are designed for quick and easy

of a desk or cabinet. Mounting options include panel-mounting, DIN-rail and rack-mount

size, Magnum Media Converters can be Velcro®-mounted on an office wall or the side

The standard “1-per-unit” external power supply plugs into a nearby AC wall

either mode type, i.e., attached devices are either both full-duplex or both half-duplex.

corresponding Media Converter or any other device. Using the Uplink Switch feature

eliminate the use of cross-over cable, see sec 4.6 for details. Because of their compact

socket or power strip. The FT14H (Hardened) media converter is also available with

models operate in transparent full- or half-duplex mode, supporting matched sets of

tray ( MC14-TRAY) that neatly holds the units and associated power supplies.

installation even in very tight spaces. Media cables are easily attached to the

Page 21 of the GarrettCom FT14 user manual — 2.2 Product Description
Page 21 · click to enlarge
Page 21

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

convey essential diagnostic and status information at any angle. See Section 4.1 and 4.4,

All of the Magnum FT14-series Media Converters comply with the IEEE 802.3

10BASE-T specification for 10 Mb/sec traffic via shielded (STP) or unshielded twisted pair (UTP) segments. The Link Pass-Through feature is especially

controlled and Industrial application. Each converter features two full sets of LEDs that

desirable for use in managed networks, and is standard in all FT14 and FT14H

that can be used in series is three. The cumulative signal noise from 4 or more

extended temperature power supply AC/DC (External/Internal) to qualify for un-

units together in series may cause packet alignment errors.

for power supply and LED function specifications.

models.

Page 22 of the GarrettCom FT14 user manual — 2.3 Features and Benefits
Page 22 · click to enlarge
Page 22

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

repeaters, and can be installed without increasing the repeater hop count

Media Converters do not add signal timing delays associated with full

single-mode fiber, transparent full- or half-duplex mode, ST connectors

Magnum Media Converters offer the ideal solution to efficiently and

inexpensively connect Twisted Pair with 10Mb Fiber media within an

A variety of twisted-pair-to-fiber models provide for multi-mode or

expanding Ethernet network where full repeaters are not required.

„ Fiber / twisted-pair models for all fiber modes

„ No added Repeater Hop Count

2.3 Features and Benefits „ Reduces Network Costs

of an existing network.

Page 23 of the GarrettCom FT14 user manual — 2.3 Features and Benefits
Page 23 · click to enlarge
Page 23

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

even when placed in extended temp; e.g industrial or outdoor applications.

Each FT14 Media Converter is equipped with a two sets (front and side)

external AC and internal DC power supplies. See Section 1.1 for details.

FT14 & FT14H Media Converters are designed for use in temperature

rugged sheet metal enclosures to ensure high reliability and durability

of LEDs to provide status information when viewed at any angle or

FT14 Media Converters have a robust design and are packaged in a

„ AC and DC Power Supplies with extended temperature ratings

un-controlled applications, and are available with variety of ratings,

mounting arrangement, rack-mount (MC14- Tray) or wall-mount.

„ Two sets of LEDs for viewing status from any angle.

„ Rugged metal case, Industrial grade

Page 24 of the GarrettCom FT14 user manual — 2.3 Features and Benefits
Page 24 · click to enlarge
Page 24

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

„ Qualified to use for temperature un-controlled “outdoor” application

the ambient temperature rating up to –40C to +75C for DC options model,

The Magnum FT14H Hardened version of media converter supports

Magnum FT14 Media Converters can be installed in minimal space in

rack mount cabinets like MC14-TRAY, on table-tops or wall-mounted.

Switch, which easily allow the media converter to cascade with other

All the Magnum FT14-series Media Converter featured with Uplink

Switch Hub or media converter, without using the cross-over cable.

Featuring a compact steel case with an external AC power supply,

„ Uplink Switch to eliminate cross-over cable while cascading

which qualified for un-controlled “outdoor” application.

„ Compact design, mount anywhere

Page 25 of the GarrettCom FT14 user manual — 2.4 Applications for FT14’s and hardened FT14H’s
Page 25 · click to enlarge
Page 25

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

supply and internal DC Power supply, enabling them to be used to convert signals among

Magnum FT14-series Media Converters are typically used where 10BASE-T

networking equipment is being installed in un-controlled temp environment and require

pair and Fiber. Equipped with wide variety of options of AC and DC power supply and

components for higher un-controlled temp qualify the FT14’s for use in office locations

2.4 Applications for FT14’s and hardened FT14H’s The primary function of a 10Mb Ethernet Media Converter is to permit two

media that does not have a power source as part of the cabling system, such as twisted

longer distance. Magnum FT14-series Media Converters have an external AC power

different 10Mb media types to coexist inexpensively within the same network by

allowing data to be transmitted and received between different media types.

as well as industrial and even outdoor applications.

Page 26 of the GarrettCom FT14 user manual — 2.4 Applications for FT14’s and hardened FT14H’s
Page 26 · click to enlarge
Page 26

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

In this application, in a Industrial environment where extended temp. supported units is a

requirement, the existing Twisted pair network can be easily connected to longer distance

Expanding longer distance through Fiber o

GarrettCom FT14 — 2.4 Applications for FT14’s and hardened FT14H’s diagram (page 26)
Fig. 8 · 2.4 Applications for FT14’s and hardened FT14H’s

through fiber media using Magnum FT14 or FT14H 10 Mb media converters.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

ptic

Page 27 of the GarrettCom FT14 user manual — Full / Half-duplex capability
Page 27 · click to enlarge
Page 27

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

at 10Mb, but might occasionally be desired to connect a 10Mb RJ-45 Switching

connect one port of a full-duplex Switching Hub via fiber to another full-duplex

without the Link Pass-through feature unless it is specially ordered with the “LP” model.

By comparison, the FT14H hardened models come with Link-Pass-through as a

receiving on the same cable segment) operation. Full-duplex is rarely required

In this regard, the FT14 models operate the same as the smaller companion product, the

Hub port over a fiber link to a full-duplex RJ-45 NIC in a remote server, or to

10Mb RJ-45 Switching Hub port. All the FT14-series operate in transparent half-and full-duplex mode. For half-duplex

2.6 Link Pass-through, features and options. The Magnum FT14 Media Converters, regular, non-hardened models, come

standard feature in order to be used with switches in industrial networks. In managed

combination is capable of full-duplex (i.e., simultaneously transmitting and

2.5 Full / Half-duplex capability For 10Mb FT14-series Media converters, the twisted-pair to fiber

traffic, the FT14-series work correctly but do not detect or indicate collisions.

Magnum TF14.

Page 28 of the GarrettCom FT14 user manual — Full / Half-duplex capability
Page 28 · click to enlarge
Page 28

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

networks, the LINK signal on a managed switch (or hub) port is used as an indicator that

SNMP agent, can troubleshoot the cabling by examining the LINK status on each port.

When a twisted-pair to fiber media converter is introduced, the FT14 regular

models of these products (not the Magnum FT14H’s) treat each attached cable segment

the attached cable segment is installed and operable. The network manager, using the

GarrettCom FT14 — Full / Half-duplex capability diagram (page 28)
Fig. 9 · Full / Half-duplex capability

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8 9

This works fine as long as all of the cabling is twisted pair.

each port, enabling an installer

to see the LINK (or no-LINK)

network software which wants

converter, treating it as part of

as a separate entity. LEDs on

piece of cable independently.

discontinuity for the managed

the FT14 Media Converters

separately indicate LINK on

status of each port and each

This is nice for the network

installer, but it introduces a

to “see through” the media

Page 29 of the GarrettCom FT14 user manual — Full / Half-duplex capability
Page 29 · click to enlarge
Page 29

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

are lit or neither is lit. And, the FT14 and FT14H’s both operate in transparent half- and

The Link-Pass-through in the FT14H models provides the LINK “see-through”

feature desired for managed networks. On the FT14H models, either both LINK LEDs

GarrettCom FT14 — Full / Half-duplex capability diagram (page 29)
Fig. 10 · Full / Half-duplex capability

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Note that a pair of F

1 2 3 4 5 6 7 8 9 1 0 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Media Converters to the other RJ-45 port, as illustrated

the cable attached to a managed switch port.

RJ-45 port can “see through” bo

media converters in series can

Where both media converters

be used to go from an RJ-45

and into another RJ-45 port.

are FT14H’s with Link Pass-

through, the LINK on each

port, through a fiber segme

full-duplex mode.

in this diagram.

nt,

Page 30 of the GarrettCom FT14 user manual — 3.0 INSTALLATION
Page 30 · click to enlarge
Page 30

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

Secure attachment of mounting

This section describes the installation of the Magnum FT14-series Media

Converters, including location, segment distance calculation and media connection.

clips for wall mounting

All the FT14-series operate in transparent half-

and full-duplex mode. For half-duplex traffic,

3.1 Locating the Media Converter Unit

The compact and lightweight design of the

the FT14-series work correctly but do not

Magnum Media Converter allows it to be

easily installed in almost any location. A

3.0 INSTALLATION

detect or indicate collisions.

Page 31 of the GarrettCom FT14 user manual — 3.0 INSTALLATION
Page 31 · click to enlarge
Page 31

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

inhibited. The green Power (PWR) Led must turn ON, when power is applied through the

Installation of the Magnum FT14 and FT14H Media Converters is a simple procedure.

The installation location is dependent upon the physical layout of the Ethernet network

Velcro strip may be used for mounting the unit on a vertical surface such as a wall or

cabinet, or for securing the unit on a table-top or shelf. Alternatively, metal mounting

accessible to an AC power outlet or power strip, and where convection cooling is not

clips and screws are included for a rugged and secure mounting in any orientation.

and associated cabling. Make sure the unit is installed in a location that is easily

internal DC input 9V, 24V or –48V DC or external AC through 9V DC jack.

Page 32 of the GarrettCom FT14 user manual — 3.2 MC14-TRAY for Rack Mounting of FT14 and FT14H Media Co
Page 32 · click to enlarge
Page 32
GarrettCom FT14 — 3.2 MC14-TRAY for Rack Mounting of FT14 and FT14H Media Co diagram (page 32)
Fig. 11 · 3.2 MC14-TRAY for Rack Mounting of FT14 and FT14H Me…

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

For 19” rack-mounting of Magnum FT14-series Media Converters, a rack-mount tray is

available, MC14-TRAY. The Media Converter units are mounted with their RJ-45 port

3.2 MC14-TRAY for Rack Mounting of FT14 and FT14H Media Converters

Any mix of the FT14-type

and DC power jack in the

Media Converters may be

back, with either fiber or

BNC cable in the front.

placed on a tray, up to a

(The mounting spaces of

maximum of 16 units.

the MC14-TRAY are

Page 33 of the GarrettCom FT14 user manual — 3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media C
Page 33 · click to enlarge
Page 33

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

(often three to eight) 14-series Media Converters, with their power supplies plugged into

supply rated at 55 watts at 50°C ambient, 9VDC output, and supporting up to 10 MC for

The MC14-TR+ PS9 and MC14-TR+PS9X2 are another option available for

A typical installation of the model MC14-TRAY, 19” rack-mount tray will hold a few

power strips (not included) in the rear area of the tray. Metal mounting screws in the

units permits the LEDs of each unit to be viewed for operational status, even when the

3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media Converters

Rack Mounting the mix-match of 10Mbps and 100Mbps Media Converters together in

19” rack-mount tray. These models comes with built-in common universal AC power

bottom-front hold the Media Converters firmly in place. The beveled-top edge of the

specific to the “14”-series, and do not permit other models).

units are very close together.

Page 34 of the GarrettCom FT14 user manual — 3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media C
Page 34 · click to enlarge
Page 34

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

MC14-TR+PS9X2 Model has two groups of eight units per power supply. These models

ranging AC input to the power

(The MC mounting spaces of

10Mbps (FT14 and TB14) and

not permit other models to be

supplies for use worldwide.

100Mb (14E) series, and do

MC14-TR+PS9 and 16 units of Fiber media converters for MC14-TR+PS9X2. The

the MC14 -TR models are

are equipped with auto-

specific to the Magnum

put in the tray).

GarrettCom FT14 — 3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media C diagram (page 34)
Fig. 12 · 3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Me…
Page 35 of the GarrettCom FT14 user manual — 3.4 DIN-Rail mounting option
Page 35 · click to enlarge
Page 35

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

The side-view picture shown here (above) is an example of an installation of

the model MC14-TR+PS9, 19” rack-mount tray, holding a few 10Mbps FT14’s and

100Mb 14E Media Converters, each with their power input plugged into the built-in

common AC power supply in the rear area of the tray. (PS units that come with the

“Factory Floor” Industrial Ethernet environments, are also available for DIN-Rail

3.4 DIN-Rail mounting option The Magnum FT14 and FT14H Media Converters, designed for use in

converters secure in the tray, separately removable for service. The dual LEDs

Metal mounting screws in the bottom-front hold each of the media

permit viewing operating status of the Media Converters from any angle.

mounting in an enclosure having DIN Rails.

MC’s are not used).

Page 36 of the GarrettCom FT14 user manual — 3.5 Calculating Overall Segment Distance
Page 36 · click to enlarge
Page 36

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

The metal DIN-Rail mounting hardware is optional and needs to be ordered as

A Magnum FT14H is shown alongside the DIN-Rail-MC2 bracket

that IEEE 802.3 specifications for overall maximum segment distances be adhered to in

GarrettCom FT14 — 3.5 Calculating Overall Segment Distance diagram (page 36)
Fig. 13 · 3.5 Calculating Overall Segment Distance

segment lengths of a Magnum FT14 and FT14H Media Converter. It is recommended

MC2. It comes with four screws to attach the

bracket to the MC unit. The rail clip is spring-

loaded with a pull-up latch at the top for easy

“HR” have 24VDC power, and have the DIN-

3.5 Calculating Overall Segment Distance

a separate item, e.g. Model # DIN-RAIL-

The Magnum FT14 Models with

Rail-MC2 bracket included and assembled

“snap-on” attachment and removal.

with the MC unit at the factory.

Page 37 of the GarrettCom FT14 user manual — 3.5 Calculating Overall Segment Distance
Page 37 · click to enlarge
Page 37

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

order to maintain optimum network performance. (See also Technical Specs, Maximum

segment length is calculated by adding together the segment lengths on both sides of the

Magnum Media Converters. Cable segment length on each side of the Media Converter

is measured as a percentage of the maximum allowable standard media distance for the

When installing the Magnum FT14-series Media Converter, it is important to consider

the combined overall segment length of both of the attached media types. The overall

given media type. The percentages, when added together, must not exceed 100%.

Standard Ethernet Segment Distances, Section 1.1 of this manual.)

Page 38 of the GarrettCom FT14 user manual — FIBER COPPER
Page 38 · click to enlarge
Page 38

Twisted Pair ( 10BASE-T)

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

GarrettCom FT14 — Twisted Pair ( 10BASE-T) diagram (page 38)
Fig. 14 · Twisted Pair ( 10BASE-T)

Connectivity between Fiber and TP Ethernet Media.

A

RX

TX

GarrettCom

LINK LINK RX/ACT

10Mb/s Media C r

Best Ethernet at its

FIBER COPPER

PWR

R

X/

A

T

9VDC .0.3AMP

onverte · Magnum FT14 · 10 Mb/s

Page 39 of the GarrettCom FT14 user manual — X% + Y% < 100%
Page 39 · click to enlarge
Page 39

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

divided by the Standard Maximum Media Distance for that media type, x 100%.

In the figure shown above, the length of Segment X is 780m (2574 ft). This is

100% = 39%]. The length of Segment Y is 55m (165 ft). This is 55% of the maximum

divided by the Standard Maximum Media Distance for that media cabling type, x 100

Where Y = The segment length on the other side of the Magnum Media Converter

39% of the maximum allowable distance for 10BASE-FL media (2Km) [780/2000 x

Where X = The segment distance on one side of the Magnum Media Converter

Media Distance Formula for Magnum Media Converters:

Connectivity between ThinNet and TP Ethernet Media.

A Distance Calculation Example:

X% + Y% < 100%

Page 40 of the GarrettCom FT14 user manual — 3.5 Calculating Overall Segment Distance
Page 40 · click to enlarge
Page 40

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

percentages for all of the cabling lengths in the run must be added together and must not

using a Magnum Repeater so that each cable type can be 100% of its maximum allowed

allowable distance for UTP 10BASE-T media (100 m) [55/100 x 100% = 55%]. The

three. The cumulative noise from four or more units together causes packet alignment

total of the two percentages (39% + 55%) is 94%, which is allowable.

exceed 100%.

length.

errors.

Page 41 of the GarrettCom FT14 user manual — 3.6 Connecting Ethernet Media
Page 41 · click to enlarge
Page 41

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

segment to the RJ-45 port on the Magnum Media Converters. The procedure is the same

very simple and straightforward. Using proper media segment, simply attach the cable

1. Using standard 10BASE-T media, insert either end of the cable with an RJ-45

Connecting Ethernet media to the Magnum FT14 Series Media Converter is

The following procedure describes how to connect a 10BASE-T twisted pair

See Sections 4.4 for details of the LEDs on the media converter models.

plug into the RJ-45 connector of the Magnum Media Converter.

3.6.1 Connecting Twisted Pair (RJ-45 ports)

for both unshielded and shielded twisted pair segments.

3.6 Connecting Ethernet Media

end to the appropriate connector.

Page 42 of the GarrettCom FT14 user manual — 3.6.2 Connecting Fiber Optic multi-mode, single mode (halfand full-
Page 42 · click to enlarge
Page 42

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

applications using the FT14-series Media Converters. All have ST-type fiber connectors.

2. Connect the other end of the cable to the corresponding device. Use the LINK

4.6 for up-link switch information.) If this does not help, ensure that the cable

maximum distance allowed. The others are used for a multi-mode fiber segment lengths

LED to ensure proper connectivity by noting that the LED will be illuminated

LED is not illuminated, change the setting of the up-link switch (See Section

3.6.2 Connecting Fiber Optic multi-mode, single mode (halfand full-

length. The following table (continued next page) is provided for general information:

when the units are powered and proper connections established. If the LINK

The following procedure applies to 10BASE-FL multi-mode and single mode

The FT14S single-mode differs from the other fiber media converters in terms of the

of up to 2km. The FT14S is used for single-mode fiber segments of up to 10km in

is connected properly at both ends and is not defective.

duplex)

Page 43 of the GarrettCom FT14 user manual — 3.6.2 Connecting Fiber Optic multi-mode, single mode (half
Page 43 · click to enlarge
Page 43

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

Multi-mode fiber 50/125, 62.5/125. 2km 850 nm Fiber Cable Type cable diameter * Max. length Wavelength

3. Connect the Transmit (TX) port (light colored post) on the Magnum Media Converter to the

Receive (RX) port of the remote device. Begin with the color-coded strand of the cable for

Single-mode fiber 2/15 - 8/60 10km 1300 nm * xx/yy are the diameters of the core and the core plus cladding respectively The values shown are typical values

1. Before connecting the fiber cable, remove the protective dust caps from the tips of the
2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue

Fiber Cable Type cable diameter * Max. length Wavelength

regular intervals; you must use the color-coded strand on the associated ports

4. Connect the Receive (RX) port (dark-colored post) on the product to the Transmit

dampened in alcohol. Make certain the connectors are clean before connecting.

(TX) port of the remote device. Use the non-color coded fiber strand for this.

connectors on the media converter. Save these dust caps for future use.

Procedure for connecting multi-mode and single-mode fiber cables:

at each end of the fiber optic segment.

this first TX-to-RX connection.

Page 44 of the GarrettCom FT14 user manual — 3.6.3 Power Budget Calculations for Fiber Media Magnum FT14-serie s
Page 44 · click to enlarge
Page 44

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

established at both ends (and when power is ON in the units at each end). If LINK is not lit

after cable connection, the normal cause is improper cable polarity. Swap the fiber cables

3.6.3 Power Budget Calculations for Fiber Media Magnum FT14-serie s

5. The LINK LED corresponding to the fiber port on the front of the product will illuminate
6. For the Link Pass-through model, connection is the same except that the LINK indication

Receiver Sensitivity and Transmitter Power are the parameters necessary to

where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,

compute the power budget. To calculate the power budget of different fiber media

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

(for standard non-Link-Pass-through models) when a proper connection has been

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

will not be present unless LINK is made for the cables on both sides.

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

installations, the following equations should be used:

on the product connector to remedy this situation.

OPB (Optical Power Budget) = PT(min) - PR(min)

Page 45 of the GarrettCom FT14 user manual — 3.6.3 Power Budget Calculations for Fiber Media Magnum FT14-
Page 45 · click to enlarge
Page 45

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

GarrettCom FT14 — 3.6.3 Power Budget Calculations for Fiber Media Magnum FT14- diagram (page 45)
Fig. 15 · 3.6.3 Power Budget Calculations for Fiber Media Magn…

Siemens’) web sites and catalogs to provide guidance to network designers and installers.

mode 10 (5) 1300 9/125 -30 -39 7 14 13 26

The following data has been collected from component manufacturer’s (HP’s and

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

passive Attenuation.

Mode Std.

single-mode 10 Mb FL Single-

Std.

Show 14 more labels / short text on this page
km · fdx · (hdx) · mode 2 (2) · Multi- · Speed, · 10 Mb FL · FT14-series · FT14S all · Fiber · Port · Module · all multi- · mode
Page 46 of the GarrettCom FT14 user manual — 4.0 OPERATION
Page 46 · click to enlarge
Page 46

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

4.1 Power Requirements, Power Supply Types for FT14 and FT14H

Magnum FT14 Media Converters are power-efficient and can work with an external AC

power supply. Magnum FT14 Media Converters require a nominal 9VDC input. version

The extended temperature –Hd version is used for heavy duty and industrial applications.

FT14 and FT14H media converters are designed to be used with UL listed Class II power

This section describes the operation of the Magnum FT14 and FT14H, 10Mb

Media Converters, including power supply requirements, up-link switch functionality,

The 9V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. The Magnum

supplies. Detail info. is provided in Technical Specifications Section 1.1.

and a description of all LEDs.

4.0 OPERATION

Page 47 of the GarrettCom FT14 user manual — 9VDC 24VDC -48VDC
Page 47 · click to enlarge
Page 47

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

withstand higher temperature environments, and provide the direct DC power choices to

DC) has a built-in terminal block for +, -, ground. The 9V DC jack is also present. Detail

information about the 9 VDC, the 24V DC and the –48V DC is provided in the Technical

Specifications Section 1.1. The various models of DC power type and extended ambient

temperature power supplies are numerous and your choice needs to be called out on your

The Internal 9V DC (8 – 15V

The FT14H Hardened media converters are designed to provide reliable operation,

9VDC 24VDC -48VDC

the user to deploy in uncontrolled temperature environments.

order.

Page 48 of the GarrettCom FT14 user manual — 4.2 Powering the FT14H (DC Direct) with 12V, 24V or –48V D
Page 48 · click to enlarge
Page 48

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

GarrettCom FT14 — 4.2 Powering the FT14H (DC Direct) with 12V, 24V or –48V D diagram (page 48)
Fig. 16 · 4.2 Powering the FT14H (DC Direct) with 12V, 24V or…

built-in screw terminals for secure attachment of the power leads. Three models support a

range of power input types. The three model choices are for use with 9VDC, 24VDC or

Each Magnum FT14H is equipped with a Direct DC power supply, and have

only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the

4.2 Powering the FT14H (DC Direct) with 12V, 24V or –48V DC power input

-48VDC power. DC power input may be chosen

rated at –40`C to +75`C. If indoors, the DC jack

The extended temperature capability

of the DC-powered FT14H’s can go outdoors,

for high-availability.

like).

Page 49 of the GarrettCom FT14 user manual — 18 – 26V DC (24V DC)
Page 49 · click to enlarge
Page 49

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

is also present and optionally can be used with an external AC power supply.

GNDTerminal for “earth” or ground wire connection to the FT14H chassis

30 – 60V DC (-48V DC)

0.4 amp max.(24V DC)

18 – 26V DC (24V DC)

Input Voltage7.5 - 15V DC (9V DC)
DC Power Terminals“+”, “-”, floating
Input current0.8 amp max.(9V DC)
Page 50 of the GarrettCom FT14 user manual — FT14H, DC-powered, -48VDC, 24VDC and 9VDC
Page 50 · click to enlarge
Page 50
GarrettCom FT14 — FT14H, DC-powered, -48VDC, 24VDC and 9VDC diagram (page 50)
Fig. 17 · FT14H, DC-powered, -48VDC, 24VDC and 9VDC

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

(as shown in Figure above). The DC terminal block on the Magnum FT14H is located on

the left side of the unit and is equipped with three (3) screw-down lead posts. The power

Power Consumption: 1.5 watts typical, 2 watts maxm.

4.3 FT14H, DC-powered, -48VDC, 24VDC and 9VDC Installation

block on the Magnum FT14H hardened media converter

0.2 amp max.(-48V DC)

9VDC leads) to the Direct DC power terminal

This section describes the proper

connection of the -48VDC leads (or 24VDC,

Page 51 of the GarrettCom FT14 user manual — FT14H, DC-powered, -48VDC, 24VDC and 9VDC
Page 51 · click to enlarge
Page 51

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

The connection procedure is straightforward. Simply insert the DC leads to the

and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead

terminals are identified as positive (+) and negative (-), and they are floating inside the

unit so that either of the terminal may be grounded by the user if desired. The chassis is

(GND) is optional; it connects to the FT14H chassis. Ensure that each lead is securely

FT14H’s power terminals, positive (+) and negative (-) screws. The use of Ground

will connect to the post labeled “+ve” and the rest to the “-ve”.

When power is applied, the green PWR LED will illuminate.

tightened from the top, as shown here.

The GND can be hooked up at the last.

“earth” or ground (GND).

Page 52 of the GarrettCom FT14 user manual — 4.4 Dual LEDs, front-panel and side-panel (Magnum FT14 and
Page 52 · click to enlarge
Page 52

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

LINK/L (TP) Illuminates GREEN, Steady ON when both attached cable segments are

lost between the ends of the twisted pair segment or a loss of power occurs in

operational at the other end. LINK will turn off in the event connectivity is

RX/ACT/A Blinking GREEN indicates data is being received, receive activity.

4.4 Dual LEDs, front-panel and side-panel (Magnum FT14 and FT14H) LED Description

(Steady On or steady Off indicates no Receive Activity).

PWR/P Illuminates GREEN to indicate power applied.

the unit or remote device.

Page 53 of the GarrettCom FT14 user manual — RJ45
Page 53 · click to enlarge
Page 53

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

End view, FT14, FT14H

The FT14 and FT14H Media Converter is equipped with an Up-Link slide switch. When

RJ45

When set to the DOWN position (=), the Magnum

set to the UP position (X), the Media Converter is

wired with cross-over functionality for direct up-

Media Converter is wired for normal twisted-pair

connection to a user node device. Some Ethernet

Switch ports may be of either polarity, and this

link to a network hub, switch or concentrator.

feature is most convenient with such switches.

4.5 Up-Link (Cross-over) Switch

Fiber · user device (=) · up-link

Page 54 of the GarrettCom FT14 user manual — 5.0 TROUBLESHOOTING
Page 54 · click to enlarge
Page 54

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

consistently high performance in all network environments. The installation of Magnum

INSTALLATION, Section 3.0); the operation is also straightforward and is discussed in

suggestions listed below prior to contacting your supplier. However, if you are unsure of

the procedures described in this section or if the Magnum FT14 / FT14H 10 Mb/s Media

Converter is not performing as expected, do not attempt to repair the unit; instead contact

intended to help locate, identify and correct these types of problems. Please follow the

Should problems develop during installation or operation, this section is

All Magnum Ethernet products are designed to provide reliability and

FT14-SERIESs 10 Mb/s Media Converters is a straightforward procedure (see

your supplier for assistance or contact GarrettCom Customer Support.

5.0 TROUBLESHOOTING

Section 4.

Page 55 of the GarrettCom FT14 user manual — 5.1 Before Calling for Assistance
Page 55 · click to enlarge
Page 55

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

1. If difficulty is encountered when installing or operating the unit, refer back to

FT14/FT14H 10 Mb/s Media Converters unit. Be certain that each AC power

the Installation Section of the applicable chapter of this manual. Also check

to make sure that the various components of the network are interoperable.

cord is plugged into a functioning electrical outlet. Use the PWR LEDs to

3. Make sure that an AC power cord is properly attached to each Magnum
2. Check the cables and connectors to ensure that they have been properly

connected and the cables/wires have not been crimped or in some way

impaired during installation. (About 90% of network downtime can be

attributed to wiring and connector problems.)

verify each unit is receiving power.

5.1 Before Calling for Assistance

Page 56 of the GarrettCom FT14 user manual — 5.1 Before Calling for Assistance
Page 56 · click to enlarge
Page 56

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

contact GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for

FT14/FT14H 10 Mb/s Media Converters product, it is recommended that the

problem device is replaced with a known good device. Verify whether or not

5. If the problem continues after completing Step 4 above, contact your supplier

of the Magnum FT14/FT14H 10 Mb/s Media Converters unit or if unknown,

corrected, the Magnum FT14/FT14H 10 Mb/s Media Converters and its

the problem is corrected. If not, go to Step 5 below. If the problem is

4. If the problem is isolated to a network device other than the Magnum

associated cables are functioning properly.

assistance.

Page 57 of the GarrettCom FT14 user manual — 5.2 When Calling for Assistance
Page 57 · click to enlarge
Page 57

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

d. Any particular application that, when used, appears to create the problem;

number(s). Include the date(s) that you purchased the products from your

1. A complete description of the problem, including the following points:
2. An accurate list of GarrettCom product model(s)involved, with serial

Please be prepared to provide the following information.

c. The components involved in the problem;

a. The nature and duration of the problem;

b. Situations when the problem occurs;

5.2 When Calling for Assistance

supplier.

Page 58 of the GarrettCom FT14 user manual — 5.3 Return Material Authorization (RMA) Procedure
Page 58 · click to enlarge
Page 58

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization

3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

4. A record of changes that have been made to your network configuration prior

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

to the occurrence of the problem. Any changes to system administration

(RMA) number. To obtain an RMA number, please use this URL -

Name and phone number of your contact person.

Please have the following information readily available:

procedures should all be noted in this record.

various network media types being used.

Name of your company / institution

Your shipping address

Page 59 of the GarrettCom FT14 user manual — 5.3 Return Material Authorization (RMA) Procedure
Page 59 · click to enlarge
Page 59

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

GarrettCom will carefully test and evaluate all returned products, will repair products

that are under warranty at no charge, and will return the warranty-repaired units to the

complete details). However, if the problem or condition causing the return cannot be

sender with shipping charges prepaid (see Warranty Information, Appendix A, for

Failure symptoms, including a full description of the problem.

Packing List Number (or Sales Order Number)

duplicated by GarrettCom, the unit will be returned as:

Serial Number (or Invoice Number)

No Problem Found.

Date of installation · Product name

Page 60 of the GarrettCom FT14 user manual — 5.3 Return Material Authorization (RMA) Procedure
Page 60 · click to enlarge
Page 60

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

GarrettCom reserves the right to charge for the testing of non-defective units

under warranty. Testing and repair of product that is not under warranty will result in a

customer (user) charge.

Page 61 of the GarrettCom FT14 user manual — 5.4 Shipping and Packaging Information
Page 61 · click to enlarge
Page 61

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

sheet or bag for shipping protection. ( You may retain all connectors and this

Should you need to ship the unit back to GarrettCom, please follow these instructions:

1. Package the unit carefully. It is recommended that you use the original

container if available. Units should be wrapped in a "bubble-wrap" plastic

2. Clearly mark the Return Material Authorization (RMA) number on the
3. GarrettCom is not responsible for your return shipping charges.

This material may cause electro-static shock damage to the unit.

5.4 Shipping and Packaging Information

outside of the shipping container.

Installation Guide.)

Page 62 of the GarrettCom FT14 user manual — APPENDIX A: WARRANTY INFORMATION
Page 62 · click to enlarge
Page 62

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

GarrettCom, Inc. warrants its products to be free from defects in materials and

workmanship for a period of three (3) years from the date of shipment by GarrettCom.

During this warranty period, GarrettCom will repair or, at its option, replace

components in the products that prove to be defective at no charge other than shipping

and handling, provided that the product is returned pre-paid to GarrettCom.

APPENDIX A: WARRANTY INFORMATION

47823 Westinghouse Dr.

Attn.: Customer Service

GarrettCom, Inc.

4. Ship the package to:

Fremont, CA 94539

Page 63 of the GarrettCom FT14 user manual — APPENDIX A: WARRANTY INFORMATION
Page 63 · click to enlarge
Page 63

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

GarrettCom reserves the right to make a charge for handling and inspecting any

Please complete the warranty card as this acts as a product registration, and

This warranty will not be effective if, in the opinion of GarrettCom, the

product has been damaged by misuse, misapplication, or as a result of service or

product returned for warranty repair which turns out not to be faulty.

mail it to GarrettCom within two weeks of your purchase.

modification other than by GarrettCom.

Ask about the GarrettCom FT14

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom FT14

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom FT14 manual PDF

63 pages·410 KB·Welding System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…