10Mb/s Media Converters Installation and User Guide


email support@garrettcom.com
47823 Westinghouse Dr. Fremont, CA 94539
GarrettCom, Inc.
ww m com w GarrettCo. .
Corporate Headquarters · Phone (510) 438-9071 · Fax (510) 438-9072

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
experienced with Magnum FT14/FT14H 10 Mb/s Media Converters products,
GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a
contains no user serviceable parts. Attempted service by unauthorized
personnel shall render all warranties null and void. If problems are
of this publication may be reproduced without prior written permission from
consult Section 5, Troubleshooting, of this User Guide.
Copyright © 2003 GarrettCom, Inc. All rights reserved. No part
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
registered trademark of GarrettCom, Inc.
Printed in the United States of America.
GarrettCom, Inc.
Trademarks

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take whatever
Radio Frequency Interference Statement
measures may be required to correct the interference.
Federal Communications Commission

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
Please use the mailing address, phone and fax numbers and email address listed below:
47823 Westinghouse Dr. Fremont, CA 94539
GarrettCom, Inc.
Fax (510) 438-9072 · Contacting GarrettCom, Inc


FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
3.6.1 Connecting Twisted Pair (RJ-45 ports)...................................... 34
3.6.2 Connecting Fiber Optic mm, sm (halfand full-duplex) ......... 35
3.6.3 Power Budget Calcs for Fiber Media Magnum FT14-serie s ...... 37
4.0 OPERATION ....................................................................................... 39
4.1 Power Requirements, Power Supply Types for FT14 and FT14H .... 39
4.2 Powering the FT14H (DC Direct) power input 41 4.3 FT14H, DC-powered, Installation 43
4.5 Up-Link (Cross-over) Switch ............................................................ 46
5.0 TROUBLESHOOTING ...................................................................... 47
5.1 Before Calling for Assistance ............................................................ 48
5.2 When Calling for Assistance ............................................................. 50
5.3 Return Material Authorization (RMA) Procedure............................. 51
5.4 Shipping and Packaging Information................................................. 54
APPENDIX A: WARRANTY INFORMATION......................................... 55

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or
model offerings without notice.
Revisions

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
(Magnum Media Converters are physical layer standard Ethernet products,
Experience shows that up to three units can be used in series between repeaters.
For 4 or more in series, noise build-up will typically preclude proper operation.
and operate independently of all software.)
Number of Media Converters in series:
1.1 Technical Specifications
Network Standards:
Performance:
802.3,

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
(-40ºC to 55ºC) FT14H-Hd,-Hi, FT14SH-Hd,Hi
(-40ºC to 75ºC) FT14H-9VDC, FT14SH-9VDC,
Section 3.2 of this manual for media lengths and segment distance calculations.
Maximum Standard Ethernet Segment Lengths:
Cold start down to -25ºC

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
rated output voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current
(i.e. 100mA to 500mA).When connected to a 48 V centralized dc source these products
Designed for NEBS compliance, including vibration, shock, and altitude
marked “Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably
UL 2043 tested for above-the –ceiling (plenum) installation
These products are intended to be supplied by a Listed, Direct Plug-In power unit,
100-240V AC at 50-60Hz, for “-Hd” high temp. with built-in IEC320 connector Power input 9V DC jack is 2.5mm center +ve jack, with 6ft. cord
Conformal coating (humidity protection) option, request quote.
shall be provided with a Listed 5 A DC fuse in the supply circuit.
UL listed Class II Power Supply ( AC-DC Adapter):
“Hd” North American models

24V DC internal (range of 18 to 36V DC)


FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

100-240V AC at 50-60Hz, for high temp. with built-in IEC320 connector for “-Hi” DC to unit:
block for +, -, ground. The 9V DC jack is also present.
-48V DC internal (range of 36 to 60V DC)
9V DC, 2.5mm jack, center +ve, 6ft. cord
9V DC internal (range of 7.5 to 15V DC)
Connectors, for Media:
“Hi” international model

LED FT14 FT14S Description
FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
FT14 and FT14H: 3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm)
segments are operational at the other end
Link(per port) TP, Fiber TP, Fiber * Steady ON when both attached cable
RX/Act TP, Fiber TP, Fiber Indicates port is receiving packets.
PWR unit unit Steady ON when power applied.
Enclosure: Rugged sheet metal (Steel).
Media Converter LED Indicators:

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
Mean Tine Between Failure (MTBF) – 15+ years, Telcordia (Bellcore) Method
UL LISTED (UL 60950), CUL, CE Emissions meet FCC Part 15, Class A
IEC61850 EMC and Operating Conditions Class C for Power Substations
Metal Mounting clips for panel mounting: included
Agency Approvals and Standard Compliance:
NEBS L3 and ETSI compliant

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
FT14HR-24V DC = TP to mm Fiber, 24V DC Internal pwr supply, -40 to 75`C, includes DIN-Rail
FT14H-Hd = TP to 10Mb mm Fiber ST, external 115 60Hz AC power supply, for -40 to 55`C
FT14H-Hi = TP to 10Mb mm Fiber ST, external 230 50Hz AC power supply, for -40 to 55`C
For a Single-mode 10Mb Fiber ST model, insert “S” after the number “14” in each line above.
DIN-RAIL-MC2 Metal DIN-Rail mounting bracket for one FT14-Series
FT14-Hd = TP to 10Mb mm Fiber ST, external 115 60Hz AC power supply, for 0 to 50`C
FT14-Hi = TP to 10Mb mm Fiber ST, external 230 50Hz AC power supply, for 0 to 50`C
FT14H-9V DC = TP to 10Mb mm Fiber ST, 12V DC Internal power supply, -40 to 75`C
FT14H-24V DC = TP to 10Mb mm Fiber ST, 24V DC Internal power supply, -40 to 75`C
FT14H-48V DC = TP to 10Mb mm Fiber ST, 24V DC Internal power supply, -40 to 75`C
MC14-TRAY = 19” Rack-mount tray for 14-series Media Converters, up to 16 units
1.2 Summary of models and descriptions:
Media Converter .

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
1 Magnum FT14 or FT14H mm or single-mode Media Converter Unit
1 External Power Supply, (except for internal DC power supply models)
1 User Guide, i.e., this manual (continued next page)
This section describes the FT14 and FT14H models, including appearance,
2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this
product; notify the carrier immediately of any damage which you believe occurred
during shipment or delivery. Inspect the contents of this package for any signs of
1 set Metal panel mounting clips and screws, 2 each
damage and ensure that the items listed below are included.
features and typical applications.
This package should contain:

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
offer a graceful way to convert and transmit data between twisted pair and Fiber network
Remove the Magnum Media Converter from the shipping container. Be sure to keep the
return the unit use the original shipping container. Refer to Section 5 Troubleshooting,
2.2 Product Description Rugged packaging, a selection of extended temperature models, choice of AC
In the event there are items missing or damaged contact your supplier. If you need to
characteristics of the Magnum 10Mb FT14 and FT14H Media Converters. All models
specifications and the IEEE 802.3 standards. Power consumed in use is 1.5 to 2 watts.
cables for media flexibility in new or expanded 10Mb Ethernet networks. The future
proof fiber comes as ST connector with Multi or Single Mode options. They provide
standard collision detection and indication, and comply with the Ethernet V1.0 / 2.0
and DC power types, ease-of-use features, and energy-efficiency are the primary
shipping container should you need to ship the unit at a later date.
for specific return procedures.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
and use an external AC power supply. A metal case with convection cooling is featured.
The FT14 regular-package units are for office and wiring closet environments

Magnum FT14 Magnum FT14H
R
GarrettCom
LINK LINK RX/ACT
onverte 10Mb/s Media C r
9VDC .0.3AMP Magnum FT14
PWR
R
X/
A
T
Ethernet at its · 10 Mb/s · Best

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
Operation may be in 0° to 50°C ambient temperature. The units can be mounted securely
heat sink. No air inflow is required for cooling, so the FT14H resists dust, dirt, moisture,
on a closet wall or metal cabinet, or by using the metal panel mounting clips included.
The FT14H Hardened unit features a sealed metal case which is also used as a
DC power are available. Storage temperature rating is up to –40°C to +75°C depending
on the power source used. The FT14H is suitable for temperature un-controlled outdoor
environments. FT14 Media Converters cost significantly less than full repeaters and can
smoke and insects, and is plenum rated. Choices of models for external AC or internal
applications. Mounting options include panel-mounting, DIN-rail, or rack-mount tray.
transmit data among twisted pair, and Fiber (Multi or Single Mode) network cabling
be used whenever media distance limitations will not be exceeded in the segment.
The FT14-series Media Converters offer a graceful way to convert and

Twisted Pair ( 10BASE-
FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
All units are compatible with Ethernet V 1.0 / 2.0 specifications and comply with IEEE

GarrettCom
onverte 10Mb/s Media C r
Best Ethernet at its
R
X/
A
T
802.3 standards.
Magnum FT14 · 10 Mb/s

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
The up-link (or crossover) switch on the RJ-45 port simplifies cable installation. All fiber
Magnum FT14-series 10Mb Media Converters are designed for quick and easy
of a desk or cabinet. Mounting options include panel-mounting, DIN-rail and rack-mount
size, Magnum Media Converters can be Velcro®-mounted on an office wall or the side
The standard “1-per-unit” external power supply plugs into a nearby AC wall
either mode type, i.e., attached devices are either both full-duplex or both half-duplex.
corresponding Media Converter or any other device. Using the Uplink Switch feature
eliminate the use of cross-over cable, see sec 4.6 for details. Because of their compact
socket or power strip. The FT14H (Hardened) media converter is also available with
models operate in transparent full- or half-duplex mode, supporting matched sets of
tray ( MC14-TRAY) that neatly holds the units and associated power supplies.
installation even in very tight spaces. Media cables are easily attached to the

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
convey essential diagnostic and status information at any angle. See Section 4.1 and 4.4,
All of the Magnum FT14-series Media Converters comply with the IEEE 802.3
10BASE-T specification for 10 Mb/sec traffic via shielded (STP) or unshielded twisted pair (UTP) segments. The Link Pass-Through feature is especially
controlled and Industrial application. Each converter features two full sets of LEDs that
desirable for use in managed networks, and is standard in all FT14 and FT14H
that can be used in series is three. The cumulative signal noise from 4 or more
extended temperature power supply AC/DC (External/Internal) to qualify for un-
units together in series may cause packet alignment errors.
for power supply and LED function specifications.
models.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
repeaters, and can be installed without increasing the repeater hop count
Media Converters do not add signal timing delays associated with full
single-mode fiber, transparent full- or half-duplex mode, ST connectors
Magnum Media Converters offer the ideal solution to efficiently and
inexpensively connect Twisted Pair with 10Mb Fiber media within an
A variety of twisted-pair-to-fiber models provide for multi-mode or
expanding Ethernet network where full repeaters are not required.
Fiber / twisted-pair models for all fiber modes
No added Repeater Hop Count
2.3 Features and Benefits Reduces Network Costs
of an existing network.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
even when placed in extended temp; e.g industrial or outdoor applications.
Each FT14 Media Converter is equipped with a two sets (front and side)
external AC and internal DC power supplies. See Section 1.1 for details.
FT14 & FT14H Media Converters are designed for use in temperature
rugged sheet metal enclosures to ensure high reliability and durability
of LEDs to provide status information when viewed at any angle or
FT14 Media Converters have a robust design and are packaged in a
AC and DC Power Supplies with extended temperature ratings
un-controlled applications, and are available with variety of ratings,
mounting arrangement, rack-mount (MC14- Tray) or wall-mount.
Two sets of LEDs for viewing status from any angle.
Rugged metal case, Industrial grade

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
Qualified to use for temperature un-controlled “outdoor” application
the ambient temperature rating up to –40C to +75C for DC options model,
The Magnum FT14H Hardened version of media converter supports
Magnum FT14 Media Converters can be installed in minimal space in
rack mount cabinets like MC14-TRAY, on table-tops or wall-mounted.
Switch, which easily allow the media converter to cascade with other
All the Magnum FT14-series Media Converter featured with Uplink
Switch Hub or media converter, without using the cross-over cable.
Featuring a compact steel case with an external AC power supply,
Uplink Switch to eliminate cross-over cable while cascading
which qualified for un-controlled “outdoor” application.
Compact design, mount anywhere

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
supply and internal DC Power supply, enabling them to be used to convert signals among
Magnum FT14-series Media Converters are typically used where 10BASE-T
networking equipment is being installed in un-controlled temp environment and require
pair and Fiber. Equipped with wide variety of options of AC and DC power supply and
components for higher un-controlled temp qualify the FT14’s for use in office locations
2.4 Applications for FT14’s and hardened FT14H’s The primary function of a 10Mb Ethernet Media Converter is to permit two
media that does not have a power source as part of the cabling system, such as twisted
longer distance. Magnum FT14-series Media Converters have an external AC power
different 10Mb media types to coexist inexpensively within the same network by
allowing data to be transmitted and received between different media types.
as well as industrial and even outdoor applications.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
In this application, in a Industrial environment where extended temp. supported units is a
requirement, the existing Twisted pair network can be easily connected to longer distance
Expanding longer distance through Fiber o

through fiber media using Magnum FT14 or FT14H 10 Mb media converters.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
ptic

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
at 10Mb, but might occasionally be desired to connect a 10Mb RJ-45 Switching
connect one port of a full-duplex Switching Hub via fiber to another full-duplex
without the Link Pass-through feature unless it is specially ordered with the “LP” model.
By comparison, the FT14H hardened models come with Link-Pass-through as a
receiving on the same cable segment) operation. Full-duplex is rarely required
In this regard, the FT14 models operate the same as the smaller companion product, the
Hub port over a fiber link to a full-duplex RJ-45 NIC in a remote server, or to
10Mb RJ-45 Switching Hub port. All the FT14-series operate in transparent half-and full-duplex mode. For half-duplex
2.6 Link Pass-through, features and options. The Magnum FT14 Media Converters, regular, non-hardened models, come
standard feature in order to be used with switches in industrial networks. In managed
combination is capable of full-duplex (i.e., simultaneously transmitting and
2.5 Full / Half-duplex capability For 10Mb FT14-series Media converters, the twisted-pair to fiber
traffic, the FT14-series work correctly but do not detect or indicate collisions.
Magnum TF14.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
networks, the LINK signal on a managed switch (or hub) port is used as an indicator that
SNMP agent, can troubleshoot the cabling by examining the LINK status on each port.
When a twisted-pair to fiber media converter is introduced, the FT14 regular
models of these products (not the Magnum FT14H’s) treat each attached cable segment
the attached cable segment is installed and operable. The network manager, using the

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9
This works fine as long as all of the cabling is twisted pair.
each port, enabling an installer
to see the LINK (or no-LINK)
network software which wants
converter, treating it as part of
as a separate entity. LEDs on
piece of cable independently.
discontinuity for the managed
the FT14 Media Converters
separately indicate LINK on
status of each port and each
This is nice for the network
installer, but it introduces a
to “see through” the media

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
are lit or neither is lit. And, the FT14 and FT14H’s both operate in transparent half- and
The Link-Pass-through in the FT14H models provides the LINK “see-through”
feature desired for managed networks. On the FT14H models, either both LINK LEDs

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Note that a pair of F
1 2 3 4 5 6 7 8 9 1 0 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Media Converters to the other RJ-45 port, as illustrated
the cable attached to a managed switch port.
RJ-45 port can “see through” bo
media converters in series can
Where both media converters
be used to go from an RJ-45
and into another RJ-45 port.
are FT14H’s with Link Pass-
through, the LINK on each
port, through a fiber segme
full-duplex mode.
in this diagram.
nt,

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
This section describes the installation of the Magnum FT14-series Media
Converters, including location, segment distance calculation and media connection.
All the FT14-series operate in transparent half-
and full-duplex mode. For half-duplex traffic,
3.1 Locating the Media Converter Unit
The compact and lightweight design of the
the FT14-series work correctly but do not
Magnum Media Converter allows it to be
easily installed in almost any location. A
detect or indicate collisions.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
inhibited. The green Power (PWR) Led must turn ON, when power is applied through the
Installation of the Magnum FT14 and FT14H Media Converters is a simple procedure.
The installation location is dependent upon the physical layout of the Ethernet network
Velcro strip may be used for mounting the unit on a vertical surface such as a wall or
cabinet, or for securing the unit on a table-top or shelf. Alternatively, metal mounting
accessible to an AC power outlet or power strip, and where convection cooling is not
clips and screws are included for a rugged and secure mounting in any orientation.
and associated cabling. Make sure the unit is installed in a location that is easily
internal DC input 9V, 24V or –48V DC or external AC through 9V DC jack.


FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
For 19” rack-mounting of Magnum FT14-series Media Converters, a rack-mount tray is
available, MC14-TRAY. The Media Converter units are mounted with their RJ-45 port
3.2 MC14-TRAY for Rack Mounting of FT14 and FT14H Media Converters
Any mix of the FT14-type
and DC power jack in the
Media Converters may be
back, with either fiber or
BNC cable in the front.
placed on a tray, up to a
(The mounting spaces of
maximum of 16 units.
the MC14-TRAY are

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
(often three to eight) 14-series Media Converters, with their power supplies plugged into
supply rated at 55 watts at 50°C ambient, 9VDC output, and supporting up to 10 MC for
The MC14-TR+ PS9 and MC14-TR+PS9X2 are another option available for
A typical installation of the model MC14-TRAY, 19” rack-mount tray will hold a few
power strips (not included) in the rear area of the tray. Metal mounting screws in the
units permits the LEDs of each unit to be viewed for operational status, even when the
3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media Converters
Rack Mounting the mix-match of 10Mbps and 100Mbps Media Converters together in
19” rack-mount tray. These models comes with built-in common universal AC power
bottom-front hold the Media Converters firmly in place. The beveled-top edge of the
specific to the “14”-series, and do not permit other models).
units are very close together.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
MC14-TR+PS9X2 Model has two groups of eight units per power supply. These models
ranging AC input to the power
(The MC mounting spaces of
10Mbps (FT14 and TB14) and
not permit other models to be
supplies for use worldwide.
100Mb (14E) series, and do
MC14-TR+PS9 and 16 units of Fiber media converters for MC14-TR+PS9X2. The
the MC14 -TR models are
are equipped with auto-
specific to the Magnum
put in the tray).


FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
The side-view picture shown here (above) is an example of an installation of
the model MC14-TR+PS9, 19” rack-mount tray, holding a few 10Mbps FT14’s and
100Mb 14E Media Converters, each with their power input plugged into the built-in
common AC power supply in the rear area of the tray. (PS units that come with the
“Factory Floor” Industrial Ethernet environments, are also available for DIN-Rail
3.4 DIN-Rail mounting option The Magnum FT14 and FT14H Media Converters, designed for use in
converters secure in the tray, separately removable for service. The dual LEDs
Metal mounting screws in the bottom-front hold each of the media
permit viewing operating status of the Media Converters from any angle.
mounting in an enclosure having DIN Rails.
MC’s are not used).

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
The metal DIN-Rail mounting hardware is optional and needs to be ordered as
A Magnum FT14H is shown alongside the DIN-Rail-MC2 bracket
that IEEE 802.3 specifications for overall maximum segment distances be adhered to in

segment lengths of a Magnum FT14 and FT14H Media Converter. It is recommended
MC2. It comes with four screws to attach the
bracket to the MC unit. The rail clip is spring-
loaded with a pull-up latch at the top for easy
“HR” have 24VDC power, and have the DIN-
3.5 Calculating Overall Segment Distance
a separate item, e.g. Model # DIN-RAIL-
The Magnum FT14 Models with
Rail-MC2 bracket included and assembled
“snap-on” attachment and removal.
with the MC unit at the factory.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
order to maintain optimum network performance. (See also Technical Specs, Maximum
segment length is calculated by adding together the segment lengths on both sides of the
Magnum Media Converters. Cable segment length on each side of the Media Converter
is measured as a percentage of the maximum allowable standard media distance for the
When installing the Magnum FT14-series Media Converter, it is important to consider
the combined overall segment length of both of the attached media types. The overall
given media type. The percentages, when added together, must not exceed 100%.
Standard Ethernet Segment Distances, Section 1.1 of this manual.)

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

Connectivity between Fiber and TP Ethernet Media.
RX
TX
GarrettCom
LINK LINK RX/ACT
10Mb/s Media C r
Best Ethernet at its
PWR
R
X/
A
T
9VDC .0.3AMP
onverte · Magnum FT14 · 10 Mb/s

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
divided by the Standard Maximum Media Distance for that media type, x 100%.
In the figure shown above, the length of Segment X is 780m (2574 ft). This is
100% = 39%]. The length of Segment Y is 55m (165 ft). This is 55% of the maximum
divided by the Standard Maximum Media Distance for that media cabling type, x 100
Where Y = The segment length on the other side of the Magnum Media Converter
39% of the maximum allowable distance for 10BASE-FL media (2Km) [780/2000 x
Where X = The segment distance on one side of the Magnum Media Converter
Media Distance Formula for Magnum Media Converters:
Connectivity between ThinNet and TP Ethernet Media.
A Distance Calculation Example:

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
percentages for all of the cabling lengths in the run must be added together and must not
using a Magnum Repeater so that each cable type can be 100% of its maximum allowed
allowable distance for UTP 10BASE-T media (100 m) [55/100 x 100% = 55%]. The
three. The cumulative noise from four or more units together causes packet alignment
total of the two percentages (39% + 55%) is 94%, which is allowable.
exceed 100%.
length.
errors.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
segment to the RJ-45 port on the Magnum Media Converters. The procedure is the same
very simple and straightforward. Using proper media segment, simply attach the cable
Connecting Ethernet media to the Magnum FT14 Series Media Converter is
The following procedure describes how to connect a 10BASE-T twisted pair
See Sections 4.4 for details of the LEDs on the media converter models.
plug into the RJ-45 connector of the Magnum Media Converter.
3.6.1 Connecting Twisted Pair (RJ-45 ports)
for both unshielded and shielded twisted pair segments.
3.6 Connecting Ethernet Media
end to the appropriate connector.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
applications using the FT14-series Media Converters. All have ST-type fiber connectors.
4.6 for up-link switch information.) If this does not help, ensure that the cable
maximum distance allowed. The others are used for a multi-mode fiber segment lengths
LED to ensure proper connectivity by noting that the LED will be illuminated
LED is not illuminated, change the setting of the up-link switch (See Section
length. The following table (continued next page) is provided for general information:
when the units are powered and proper connections established. If the LINK
The following procedure applies to 10BASE-FL multi-mode and single mode
The FT14S single-mode differs from the other fiber media converters in terms of the
of up to 2km. The FT14S is used for single-mode fiber segments of up to 10km in
is connected properly at both ends and is not defective.
duplex)

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
Multi-mode fiber 50/125, 62.5/125. 2km 850 nm Fiber Cable Type cable diameter * Max. length Wavelength
Receive (RX) port of the remote device. Begin with the color-coded strand of the cable for
Single-mode fiber 2/15 - 8/60 10km 1300 nm * xx/yy are the diameters of the core and the core plus cladding respectively The values shown are typical values
Fiber Cable Type cable diameter * Max. length Wavelength
regular intervals; you must use the color-coded strand on the associated ports
dampened in alcohol. Make certain the connectors are clean before connecting.
(TX) port of the remote device. Use the non-color coded fiber strand for this.
connectors on the media converter. Save these dust caps for future use.
Procedure for connecting multi-mode and single-mode fiber cables:
at each end of the fiber optic segment.
this first TX-to-RX connection.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
established at both ends (and when power is ON in the units at each end). If LINK is not lit
after cable connection, the normal cause is improper cable polarity. Swap the fiber cables
Receiver Sensitivity and Transmitter Power are the parameters necessary to
where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,
compute the power budget. To calculate the power budget of different fiber media
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
(for standard non-Link-Pass-through models) when a proper connection has been
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
will not be present unless LINK is made for the cables on both sides.
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
installations, the following equations should be used:
on the product connector to remedy this situation.
OPB (Optical Power Budget) = PT(min) - PR(min)

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

Siemens’) web sites and catalogs to provide guidance to network designers and installers.
mode 10 (5) 1300 9/125 -30 -39 7 14 13 26
The following data has been collected from component manufacturer’s (HP’s and
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
passive Attenuation.
Mode Std.
single-mode 10 Mb FL Single-
Std.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
4.1 Power Requirements, Power Supply Types for FT14 and FT14H
Magnum FT14 Media Converters are power-efficient and can work with an external AC
power supply. Magnum FT14 Media Converters require a nominal 9VDC input. version
The extended temperature –Hd version is used for heavy duty and industrial applications.
FT14 and FT14H media converters are designed to be used with UL listed Class II power
This section describes the operation of the Magnum FT14 and FT14H, 10Mb
Media Converters, including power supply requirements, up-link switch functionality,
The 9V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. The Magnum
supplies. Detail info. is provided in Technical Specifications Section 1.1.
and a description of all LEDs.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
withstand higher temperature environments, and provide the direct DC power choices to
DC) has a built-in terminal block for +, -, ground. The 9V DC jack is also present. Detail
information about the 9 VDC, the 24V DC and the –48V DC is provided in the Technical
Specifications Section 1.1. The various models of DC power type and extended ambient
temperature power supplies are numerous and your choice needs to be called out on your
The Internal 9V DC (8 – 15V
The FT14H Hardened media converters are designed to provide reliable operation,
the user to deploy in uncontrolled temperature environments.
order.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)

built-in screw terminals for secure attachment of the power leads. Three models support a
range of power input types. The three model choices are for use with 9VDC, 24VDC or
Each Magnum FT14H is equipped with a Direct DC power supply, and have
only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the
4.2 Powering the FT14H (DC Direct) with 12V, 24V or –48V DC power input
-48VDC power. DC power input may be chosen
rated at –40`C to +75`C. If indoors, the DC jack
The extended temperature capability
of the DC-powered FT14H’s can go outdoors,
for high-availability.
like).

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
is also present and optionally can be used with an external AC power supply.
0.4 amp max.(24V DC)


FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
(as shown in Figure above). The DC terminal block on the Magnum FT14H is located on
the left side of the unit and is equipped with three (3) screw-down lead posts. The power
Power Consumption: 1.5 watts typical, 2 watts maxm.
4.3 FT14H, DC-powered, -48VDC, 24VDC and 9VDC Installation
block on the Magnum FT14H hardened media converter
0.2 amp max.(-48V DC)
9VDC leads) to the Direct DC power terminal
This section describes the proper
connection of the -48VDC leads (or 24VDC,

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
The connection procedure is straightforward. Simply insert the DC leads to the
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead
terminals are identified as positive (+) and negative (-), and they are floating inside the
unit so that either of the terminal may be grounded by the user if desired. The chassis is
(GND) is optional; it connects to the FT14H chassis. Ensure that each lead is securely
FT14H’s power terminals, positive (+) and negative (-) screws. The use of Ground
will connect to the post labeled “+ve” and the rest to the “-ve”.
When power is applied, the green PWR LED will illuminate.
tightened from the top, as shown here.
The GND can be hooked up at the last.
“earth” or ground (GND).

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
LINK/L (TP) Illuminates GREEN, Steady ON when both attached cable segments are
lost between the ends of the twisted pair segment or a loss of power occurs in
operational at the other end. LINK will turn off in the event connectivity is
RX/ACT/A Blinking GREEN indicates data is being received, receive activity.
4.4 Dual LEDs, front-panel and side-panel (Magnum FT14 and FT14H) LED Description
(Steady On or steady Off indicates no Receive Activity).
PWR/P Illuminates GREEN to indicate power applied.
the unit or remote device.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
End view, FT14, FT14H
The FT14 and FT14H Media Converter is equipped with an Up-Link slide switch. When
When set to the DOWN position (=), the Magnum
set to the UP position (X), the Media Converter is
wired with cross-over functionality for direct up-
Media Converter is wired for normal twisted-pair
connection to a user node device. Some Ethernet
Switch ports may be of either polarity, and this
link to a network hub, switch or concentrator.
feature is most convenient with such switches.
4.5 Up-Link (Cross-over) Switch
Fiber · user device (=) · up-link

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
consistently high performance in all network environments. The installation of Magnum
INSTALLATION, Section 3.0); the operation is also straightforward and is discussed in
suggestions listed below prior to contacting your supplier. However, if you are unsure of
the procedures described in this section or if the Magnum FT14 / FT14H 10 Mb/s Media
Converter is not performing as expected, do not attempt to repair the unit; instead contact
intended to help locate, identify and correct these types of problems. Please follow the
Should problems develop during installation or operation, this section is
All Magnum Ethernet products are designed to provide reliability and
FT14-SERIESs 10 Mb/s Media Converters is a straightforward procedure (see
your supplier for assistance or contact GarrettCom Customer Support.
Section 4.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
FT14/FT14H 10 Mb/s Media Converters unit. Be certain that each AC power
the Installation Section of the applicable chapter of this manual. Also check
to make sure that the various components of the network are interoperable.
cord is plugged into a functioning electrical outlet. Use the PWR LEDs to
connected and the cables/wires have not been crimped or in some way
impaired during installation. (About 90% of network downtime can be
attributed to wiring and connector problems.)
verify each unit is receiving power.
5.1 Before Calling for Assistance

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
contact GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for
FT14/FT14H 10 Mb/s Media Converters product, it is recommended that the
problem device is replaced with a known good device. Verify whether or not
of the Magnum FT14/FT14H 10 Mb/s Media Converters unit or if unknown,
corrected, the Magnum FT14/FT14H 10 Mb/s Media Converters and its
the problem is corrected. If not, go to Step 5 below. If the problem is
associated cables are functioning properly.
assistance.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
d. Any particular application that, when used, appears to create the problem;
number(s). Include the date(s) that you purchased the products from your
Please be prepared to provide the following information.
c. The components involved in the problem;
a. The nature and duration of the problem;
b. Situations when the problem occurs;
5.2 When Calling for Assistance
supplier.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization
including personal computers, workstations, terminals and printers; plus, the
https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.
to the occurrence of the problem. Any changes to system administration
(RMA) number. To obtain an RMA number, please use this URL -
Name and phone number of your contact person.
Please have the following information readily available:
procedures should all be noted in this record.
various network media types being used.
Name of your company / institution
Your shipping address

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
GarrettCom will carefully test and evaluate all returned products, will repair products
that are under warranty at no charge, and will return the warranty-repaired units to the
complete details). However, if the problem or condition causing the return cannot be
sender with shipping charges prepaid (see Warranty Information, Appendix A, for
Failure symptoms, including a full description of the problem.
Packing List Number (or Sales Order Number)
duplicated by GarrettCom, the unit will be returned as:
Serial Number (or Invoice Number)
No Problem Found.
Date of installation · Product name

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
GarrettCom reserves the right to charge for the testing of non-defective units
under warranty. Testing and repair of product that is not under warranty will result in a
customer (user) charge.

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
sheet or bag for shipping protection. ( You may retain all connectors and this
Should you need to ship the unit back to GarrettCom, please follow these instructions:
container if available. Units should be wrapped in a "bubble-wrap" plastic
This material may cause electro-static shock damage to the unit.
5.4 Shipping and Packaging Information
outside of the shipping container.
Installation Guide.)

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
GarrettCom, Inc. warrants its products to be free from defects in materials and
workmanship for a period of three (3) years from the date of shipment by GarrettCom.
During this warranty period, GarrettCom will repair or, at its option, replace
components in the products that prove to be defective at no charge other than shipping
and handling, provided that the product is returned pre-paid to GarrettCom.
47823 Westinghouse Dr.
Attn.: Customer Service
GarrettCom, Inc.
Fremont, CA 94539

FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/04)
GarrettCom reserves the right to make a charge for handling and inspecting any
Please complete the warranty card as this acts as a product registration, and
This warranty will not be effective if, in the opinion of GarrettCom, the
product has been damaged by misuse, misapplication, or as a result of service or
product returned for warranty repair which turns out not to be faulty.
mail it to GarrettCom within two weeks of your purchase.
modification other than by GarrettCom.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.