Installation and User Guide
Magnum 6K16-Series
Magnum 6K16V mounted vertically
Two 6K16s mounted side-by-side on Tray


Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06)
render all warranties null and void. If problems are experienced with Magnum
6K16-Series Switch products, consult Section 6, Troubleshootings, of this User
GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a
user serviceable parts. Attempted service by unauthorized personnel shall
of this publication may be reproduced without prior written permission from
Copyright © 2006 GarrettCom, Inc. All rights reserved. No part
Managed Fiber Switch
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
registered trademark of GarrettCom, Inc.
Printed in the United States of America.
GarrettCom, Inc.
Guide.
Trademarks

Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06)
This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take whatever
Please use the mailing address, phone and fax numbers and email address listed below:
Cet appareil respecte toutes les exigences du Réglement sur le matériel du
This Class A digital apparatus meets all requirements of the Canadian
Radio Frequency Interference Statement
Radio Frequency Interference Statement
email support@garrettcom.com
47823 Westinghouse Dr. Fremont, CA 94539-7437
measures may be required to correct the interference.
GarrettCom, Inc.
Interference-Causing Equipment Regulations.
Canada. Cet appareil est Classe A..



5.2 6KPM Module Description 47 5.2.1 6KP6-RJMST, Combo Module 48 5.2.1a 6KP6-RJ10ST, Combo Module 48 5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module49 5.2.1c 6KP4-FLSTFX, Module 49 5.2.2. 6KP6-RJMSC Fiber connector 50 5.2.3 6KP6-RJSSC connector 51 5.2.4 6KP6-RJSSCL connector 51 5.2.4a 6KP6-RJ10ST connector 52 5.2.5 6KP8-MTRJ, Small-Form-factor 52 5.2.5a 6KP6-MT10ST, ST-Fiber port 53 5.2.6 6KP8-45MT, FX , MTRJ Small-Form-Factor 53 5.2.7 6KP8-MLC, LC connector Small-Form Factor 54 5.2.8 6KP8-45LC, Combo factor 54 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port 55 5.2.10 New PoE(Power Pass-through), P6KP8V-RJ45 (MDIX), 8-port 56
4.1 Switching Functionality..................................................................... 42
4.2 Status LEDs ....................................................................................... 43
4.3 Up-link Manual Switches set as (=) , for RJ-45 port only 43
4.5 Flow-control, IEEE 802.3x standard ................................................. 45
5.1 Inspecting the Package and Product .................................................. 47
5.2.11 6KP8-45-2MT, FX , MTRJ Small-Form-Factor 57 5.2.12a 6KP8-45-2LC, single-mode FX , LC Small-Form-Factor 57 5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector57
5.2.14 6KM-BLNK............................................................................... 59 6.0 TROUBLESHOOTING ...................................................................... 59
6.1 Before Calling for Assistance ............................................................ 60
6.2 When Calling for Assistance ............................................................. 60
6.3 Return Material Authorization (RMA) Procedure............................. 61
6.4 Shipping and Packaging Information................................................. 61
APPENDIX A: WARRANTY INFORMATION......................................... 62
APPENDIX B : Internal DC Power Supply Options.................................... 62
APPENDIX C: Internal DC Dual-Source Power Option............................. 65
Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06)

Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06)
06/07: Minor updates to power supply ratings 05/07: minor update to notes for power substations 04/06: minor updates as PoE modules option added on Sec 5.2.10/11 10/05: minor updates as MDIX support added on all RJ-45 port modules 02/05: minor updates and tweaks on LC port module 07/04 : 6K16 carrier class managed switch has been added with 6K16V 01/04: Added Section 3.5 (Alarm Contacts) and 3.7.1 (Console Port pins) 12/03: Updated Section 3.3 “DIN-Rail”, and Appendix B “DC Power” 10/03 : Initial Release with Rev A
Revisions

COPPER PORTS, MIX-AND MATCH. FEATURES SFF FIBER AND DC POWER IN 1U UNITS.
BNC OF FIBER PORT 8 OR 9-PORT AND 4 OR 5-PORT PERSONAL HUBS, W/ MAN. UP-LINK
GARRETTCOM, INC. OFFERS THE PREMIUM-QUALITY MAGNUM ™
LINE OF INDUSTRIAL CONECTIVITY PRODUCTS WITH INDUSTRY-
STANDARD FUNCTIONALITY AND BUILT-IN FIBER
CONFIGURABILITY. MAGNUM PRODUCTS ARE DESIGNED FOR USE
IN DEMANDING INDUSTRIAL GRADE, CARRIER CLASS, POWER
UTILITY AND OEM APPLICATIONS WHERE RELIABILITY IS A
MEDIA CONVERTERS, 10MB AND 100MB SERIES, ALL MEDIA COMBINATIONS, INCL.
QUAD-SERIES FIBER SWITCHES, 100 & 10MBPS, FIBER AND COPPER PORTS, MIXED-
PERSONAL HUBS, 100MB OR 10/100MB 8-PORT, WITH 2 SWITCHED PORTS (1 FIBER
PERSONAL HUBS, 10MB SERIES 8-PORT + AUI, STACKABLE TO 5 HIGH, + OPTIONAL
6K-SERIES MANAGED FIELD SWITCHES, GIGABIT, 100 AND 10 MBPS, FIBER AND
4K-SERIES SWITCHES, 100 AND 10 MBPS, COPPER PORTS WITH OPTIONAL FIBER
UNCONTROLLED LOCATIONS, 6 10/100 AND 2 100MB FIBER PORTS, CAN BE
PORT, WITH AUTO-NEGOTIATING FULL SWITCHING PERFORMANCE.
SPEED AND MIXED-MEDIA TYPES, FULL SWITCHING PERFORMANCE.
REPEATER PORT MODULES (RPMS), 6 TYPES FOR ETHERNET MEDIA
"Designed and Manufactured in the USA"
THE MAGNUM LINE
DX-SERIES SERIAL DEVICE ROUTERS , ETHERNET AND SERIAL
THE “X-LINE” OF CONFIGURABLE MIXED MEDIA PRODUCTS:
8 PORT DUAL-SPEED, AUTO-NEGOTIABLE WITH FIBER OPTION
MIXED-MEDIA FIBER HUB, 16-PORT, 10/100 AUTO-SENSING
MINI-CONCENTRATORS, 7 PORTS, REPEATERS , 2-PORTS
Overview
COAX TRANSCEIVERS, 10MB SERIES
PRIMARY CONSIDERATION.
FIBER ST, SC, MM., SINGLE MODE
CONNECTED IN STRINGS
BUILT IN)
SW.
Industrial networking products

100BASE-FX, full-duplex, single-mode - 20.0 km (66K16-Series ft)
Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL
100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)
Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX
Unshielded twisted pair - 100 m (328 ft)
10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)
10BASE-FL single-mode fiber optic - 10 km (32,810 ft)
10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)
Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX
100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)
100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)
1000BASE-T (CAT5e or higher is recommended) - 100 m (328 ft) 1000BASE-SX, full-duplex, multi-mode(62.5µm cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50µm cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5µm cable) -5Km Fiber Multi-mode connector types supported:
Shielded twisted pair - 150 m (492 ft)
Shielded twisted pair - 150 m (492 ft)
15 µs + packet time (10 to 10 Mbps, and 10 to 100Mbps)
Maximum Standard Gigabit Ethernet Segment Lengths:
Maximum Standard Fast Ethernet Segment Lengths:
Fiber Port, 1000BASE-FX, GBIC modules
Network Standards and Compliance, hardware
Maximum 10 Mbps Ethernet Segment Lengths
duplex flow -control, non-blocking
Filtering / Forwarding Rate:
Ethernet(10Mb):14,880 pps
1.0 SPECIFICATIONS
Performance

-40° to 140° F (-40° to 60°C) for UL60950 and Component Parts rating
-60° to 205° F (-50° to 95°C) for IEC 60068 Type Test short term rating
DB-9 for RS-232 “null-modem” cable (sometimes called an X-modem cable)
One NC indicating internal power, one NC software controllable
Conformal Coating (humidity protection) option: Request quote
Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX
50 watts typical (for a fully loaded fiber model) 30 watts typical (for a fully-loaded copper only model)
24.1 cm H x 22.2 cm W x 4.4 cm D
Enclosure: Rugged High strength sheet metal.
Fiber Port, 1000BASE-FX, GBIC modules
OFF = Half-Duplex Mode
Per Port (one set at the port) 6K16
Fiber Single-mode connector types:
Ambient Temperature:
DC Power Supply (Options)
Power Consumption:

including Dual Source options (for continuity of operation when either of the
The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45
ports., and eliminate the use of cross-over cable between the devices. Also
port-specific user settings (such as FDX or HDX, copper 10/100 speed) can
Vertical mounting only Suitable for wall or DIN-Rail mounting (6K16V)
Horizontal , Rack-mount, 2 units side-by-side on 19” or 21”rack (6K16)
IEC 61850 EMC and Operating Conditions Class C for Power Substations
IEEE 1613 Class 2 Environmental Standard for Electric Power Substations
IEC 61850 EMC and Operating Conditions Class C for Power Substations
See also Note for Power Substations in Section 3.2.4, 3.7, and 5.2.9
See also Note for Power Substations in Section 3.2.4, 3.7, and 5.2.9
For DC internal power supplies at –48VDC, 24VDC and 125VDC,
UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A
UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class B
IEEE 1613 Environmental Standard for Electric Power Substations
DC input sources are interrupted), see Appendices B and C.
NEMA TS-2 and TEES for traffic control equipment
NEMA TS-2 and TEES for traffic control equipment
Email sales@GarrettCom.com for details.
Agency Approvals and Standard Compliance
NEBS Level 3 and ETSI Compliant
be fixed using software commands.
NEBS Level 3 and ETSI Compliant
Per-port MDI or MDIX on RJ-45
Mountings:
Magnum 6K16V · Magnum 6K16

fiber and copper port connector types, 16 total ports max. Two metal brackets for vertical
240KB packet buffers for 10/100 and 120KB for 1000Mb. For licensed managed networks software (MNS-6K and S-ring), See separate data sheets.
6KP5V-G4RJ “G+2” module, w/one GBIC transceiver&four 10/100 RJ-45 connectors
wall or panel mounting. Wire speed filtering and forwarding across all ports, 802.3x flow
6KP8V-45MLC “4+4” module, w/four RJ-45 ports and four 2km mm LC connectors 6KP8V-45SLC “4+4” module, w/four RJ-45 ports and four 2km sgl-m LC connectors
6KP4V-FXSC “2+2” 100Mb Fiber module, w/ four 100Mb 2km FX SC connectors
6KP4V-FXST “2+2” 100Mb Fiber module, w/ four 100Mb 2km FX ST connectors
6KP6V-RJMST “4+2” module, w/four RJ-45 ports and two 2km mm FX ST’s 6KP6V-RJMSC “4+2” module, w/four RJ-45 ports and two 2km mm FX SC‘s 6KP6V-RJSSC “4+2” module, w/four RJ-45 ports and two 20km Sgl.m FX SC’s 6KP6V-RJSSCL “4+2” module, w/four RJ-45 ports and two 40km Sgl.m FX SC’s 6KP6V-MT10ST “4+2” module, w/four MTRJ ports and two 10Mb 2km FL ST’s 6KP6V-RJ10ST “4+2” module, w/four RJ-45 ports and two 10Mb 2km FL ST ‘s 6KM-BLNK Blank cover for one 6K16V (A,B) module slot opening in a 6K16V
6KP3V-G2SC “G+2” module, w/one GBIC transceiver and two 100Mb 2km FX SC
mounting. Worldwide AC power. May be configured with a selection of 10/100/1000
control, 802.1p priority packet processing, self-learning 4K-node address table, large
6KP4V-FLSTFX “2+2” ST Fiber module, w/ two 100Mb & two 10Mb ports, 2km 6KP8V-45-2MT “6+2” module, w/six RJ-45 ports and two 100Mb 2km FX MTRJ’s 6KP8V-45-2LC “6+2” module, w/six RJ-45 ports and two 100Mb 2km FX LC’ 6KP8V-RJ45 TP Module, w/eight 10/100Mbps auto-negotiating RJ-45 ports
6KP8V-45MT “4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s
6KP4V-F10ST “2+2” 10Mb Fiber module, w/ four 10Mb 2km FL ST connectors
Magnum 6K16V -Magnum 6K16V Managed Fiber Switch, base unit for vertical
6KP8V-MTRJ SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors
6KP8V-SLC SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors
6KP8V-MLC SFF Fiber module, w/eight 100Mbps mm FX LC connectors
Each Magnum 6K16V base unit has TWO port module slots
Gigabit (1000Mb) module option for Magnum 6K16V
1.2 Ordering Information
Magnum 6K16V Port Modules
Configuration Options:
fiber ports connector · fused

Series unit, with screws to attach to metal mounting brackets and to the 6K16-Series case.
GBPMV-2OTX Two-port Gigabit 6K module for 6K16-Series Switches, provides two
GBPMV-COTX One slot Gigabit 6K module for 6K16-Series Switches, uses one 6K16-
Magnum 6K16 -Magnum 6K16 Managed Carrier Class Switch, base unit for Horizontal
and 120KB for 1000Mb. For licensed managed networks software (MNS-6K and S-ring),
6KP8-45SLC “4+4” module, w/four RJ-45 ports and four 2km sgl-m LC connectors
6KM-BLNK Blank cover for one 6K16-Series (A,B) module slot opening in a 6K16-
DIN-RAIL-VRM Set of two DIN-Rail holders for a secure vertical mount of a 6K16-
processing, self-learning 4K-node address table, large 240KB packet buffers for 10/100
6KP4-FXSC “2+2” 100Mb Fiber module, w/ four 100Mb 2km FX SC connectors
6KP4-FXST “2+2” 100Mb Fiber module, w/ four 100Mb 2km FX ST connectors
6KP8-45MLC “4+4” module, w/four RJ-45 ports and four 2km mm LC connectors
6KP4-FLSTFX “2+2” ST Fiber module, w/ two 100Mb & two 10Mb ports, 2km 6KP8-45-2MT “6+2” module, w/six RJ-45 ports and two 100Mb 2km FX MTRJ’s
6KP8-45MT “4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s
Series slot and provides one GBIC open transceiver port for a user-selectable GBIC
10/100/1000 fiber and copper port connector types, 16 total ports max. Wire speed filtering and forwarding across all ports, 802.3x flow control, 802.1p priority packet
6KP4-F10ST “2+2” 10Mb Fiber module, w/ four 10Mb 2km FL ST connectors
6KP6-RJSSC “4+2” module, w/four RJ-45 ports and two 20km Sgl.m FX SC’s
6KP6-RJSSCL “4+2” module, w/four RJ-45 ports and two 40km Sgl.m FX SC’s
6KP6-MT10ST “4+2” module, w/four MTRJ ports and two 10Mb 2km FL ST’s 6KP6-RJ10ST “4+2” module, w/four RJ-45 ports and two 10Mb 2km FL ST ‘s
6KP8-45-2LC “6+2” module, w/six RJ-45 ports and two 100Mb 2km FX LC’s
or rack-mounting. Worldwide AC power. May be configured with a selection of
6KP8-MTRJ SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors
6KP8-SLC SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors
6KP8-RJ45 TP Module, w/eight 10/100Mbps auto-negotiating RJ-45 ports
6KP6-RJMST “4+2” module, w/four RJ-45 ports and two 2km mm FX ST’s
6KP6-RJMSC “4+2” module, w/four RJ-45 ports and two 2km mm FX SC‘s
6KP8-MLC SFF Fiber module, w/eight 100Mbps mm FX LC connectors
GBIC open transceiver port for a user-selectable GBIC transceiver module
Each Magnum 6K16 base unit has TWO port module slots
Magnum 6K16 Port Modules
See separate data sheets.
Configuration Options:
transceiver module · Series

K16-RMB Set of two rack-mount brackets for one 6K16 unit in a 19” RETMA 1U rack
GBIC-SXSC GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-SX
GBIC-ZXSC40 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX
GBIC-ZXSC70 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX
GBPM-2OTX Two-port Gigabit 6K module for 6K16-Series Switches, provides two
GBPM-COTX One slot Gigabit 6K module for 6K16-Series Switches, uses one 6K16-
space, with screws to attach the metal mounting brackets to the case. Can add Model K16-
K16-2TRAY Rack mount tray fro holding two side-by-side 6K16’s in a 19” 1.5U rack
6KP3-G2SC “G+2” module, w/one GBIC transceiver and two 100Mb 2km FX SC
K16-EXTN-KIT Kit of extender brackets for converting one K16-RMB or one K16-
GBIC-LXSC10 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-
GBIC-LXSC25 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-
1000BASE-T port, RJ-45 connector CONSOLE CBL Industry standard serial cable, DB-9 connectors for RS-232 “ null-
modem “ connection (sometimes called an X-modem cable), used to connect a PC or a
CONSOLE USB Industry standard serial cable, DB-9 connectors for RS-232 “ null-
space, each 6K16 unit individually removable for service. Can add Model K16-EXTN-
Series slot and provides one GBIC open transceiver port for a user-selectable GBIC
2TRAY to ETSI and/or to 23” Telco rack. Gigabit(1000Mb) Transceivers option for Mangum 6K16-Series (6K16V/6K16)
modem “ connection (sometimes called an X-modem cable) to connect to a managed
6KP5-G4RJ “G+2” module, w/one GBIC transceiver and four 10/100 RJ-45
GBIC transceiver module for use in GBPM-COTX, one LX port with mm SC fiber
GBIC-TP GBIC transceiver module for use in GBPM-xOTX, one 802.3ab
GBIC open transceiver port for a user-selectable GBIC transceiver module
Please see next page for PoE option and Modules
LX/LH port with 1310nm sgl. mode SC(10km) fiber connector
LX/LH port with 1310nm sgl. mode SC(25km) fiber connector
Gigabit (1000Mb) module option for Magnum 6K16V
port with 1550nm, sgl. mode SC(40km) fiber connector
port with 1550nm, sgl. mode SC(70km) fiber connector
EXTN-KIT to extend to ETSI and 23” rack width.
KIT to extend to ETSI and 23” rack width.
character terminal to the Management port.
switch, and a USB port to connect to a PC
port with mm SC fiber connector

New P6KP8-RJ45 8 port PoE module for 6ks with 48vdc PS, w/eight PoE power source
New P6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors
New P6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
10/100 auto-negotiating auto cross RJ-45 ports. New P6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
GarrettCom, Inc. reserves the right to change specifications, performance
48VDC power input may be configured with a PoE Modules
source and four 10/100 auto-negotiating auto cross RJ-45 ports
characteristics and/or model offerings without notice.
source and four 100 Mb 2km mm FX MTRJ connectors
source and four 100 Mb 2km mm FX LC connectors
source and four 100 Mb 15km sm FX LC connectors
source and four 100 Mb 15km Sm FX LC connectors
source and two 100 Mb 2km mm FX ST connectors
source and two 100 Mb 2km mm FX SC connectors
source and two 100 Mb 20km sm FX SC connectors
source and two 100 Mb 40km sm FX SC connectors
source and two 10 Mb 2km sm FL ST connectors

In the event there are items missing or damaged, contact the party from whom
product; notify the carrier of any damage that you believe occurred during shipment or
delivery. Inspect the contents of this package for any signs of damage and ensure that
Remove the items from the shipping container. Be sure to keep the shipping
shipping container if possible. Refer to Section 6, Troubleshooting, for specific return
Examine the shipping container for obvious damage prior to installing this
container should you need to re-ship the unit at a later date. To validate the product
1 Set of two metal vertical mounting brackets, with screws to the case
you purchased the product. If the unit needs to be returned, please use the original
warranty, please complete and return the enclosed Product Registration Card to
(configured with user-selected port module options installed)
1 AC Power Cord (U.S. and other 115 VAC only) if AC version
1 Magnum 6K16-Series Managed Fiber Switch, base unit
1 Installation and User Guide (this manual)
1 Product Registration Card
This package should contain:
GarrettCom, Inc. as soon as possible.
the items listed below are included.
procedures.

combination of 10Mb, 100Mb and Gigabit speed ports, with comprehensive management
software in a compact industrial-grade package. Setting a new standard for Industrial and
inside PoE modules on one of A or B slot and allows the users to select a wide option of
PoE standard. The PoE switch ports have an auto-sensing algorithm, so that they provide
as backbone switches where a mix of bursty data traffic and priority streaming traffic for
method, or -50˚C to 95˚C by the IEC 60068 Type Test method. With options such as all
hardened Magnum 6K16-Series is a “multi-purpose” Industrial Ethernet Switch.
Devices (PD)(e.g wireless access points, IP phones) that comply with the IEEE 802.3af
power only to 802.3af, PoE end devices. PoE is managed by a multi-stage handshake
will discontinue supplying power when the PoE powered devices are disconnected, and
Traffic Prioritization. Magnum 6K16-Series switches are “plug-and-play” ready for use
6K16V models, and equipped with 16 modular ports, is specially designed to focus on
two different aspects of Ethernet markets to meet their needs and requirements. 6K16-
Carrier Class applications, heavy duty Ethernet Switch jobs are readily accommodated
connector types, multi- and single-mode) and 10/100 Mb auto-negotiating RJ-45 ports.
combo PoE modules to support 802.3af pd devices. See details for PoE modules in sec
5.2.10. The Power Sourcing Equipment (PSE), and are fully compatible with Powered
Magnum 6K16-Series Managed Switches, available as Magnum 6K16 and
The 6K16- Series managed switches also provides PoE option via power –
to protect equipment from damage and to manage power budgets.The PoE ports
Magnum 6K16-Series Fiber Switches are provided with LAN management
with an extended temperature rating of -40˚C to 60˚C by the UL Component Parts
High performance features include non-blocking speed on all ports and 802.1p QoS
software including SNMP, Tag- and Port-based VLANs, IGMP Snooping and Port
Series managed switches provide modularity of fiber and copper ports, a mix and
popular DC power input types, worldwide AC power and DIN-Rail mounting, the
The large family of port modules offer the choice of all fiber media (all
Standard GBIC ports can be configured for a variety of Gigabit cabling types and
support the 802.3af PoE PSE standard for over-current protection, under-current
VoIP and audio/video “Triple Play” applications are present.
detection, and fault protection.
distances.

are available. See the Managed Networks Software (MNS-6K) and S-Ring datasheets for
Alarm Relay contacts provided on each Magnum 6K16-Series Switch monitor
Security with control via Web and command line interface (CLI). For high availability
24V, 48V, 125V) are supported, and dual source input is optional on all except 5VDC..
The wide selections of port modules are key to the flexibility and adaptability.
multiple speed 10/100/1000Mb support, rich MNS-6K management features , hardware
healing ring structures, redundancy, security and gigabit backbone configurability. The
LANs using ring topologies, Spanning Tree Protocol, Link-Loss-Learn and S-Ring
the hardware and software providing a loss of power signal and user- defined software
Magnum 6K16-Series Managed Fiber Switches have heavy duty
worldwide. Internal DC power supplies are optional. All DC power input types (5V,
The Magnum 6K16V model of 6K16-Series family, is primarily designed to use for

industrial factory-floors. For the fast growing demands of video surveillance systems
The next generation of industrial applications will need advanced managed network
software, operation at extended temperatures, fiber ports modularity, support for self-
metal cases and auto-ranging power supplies for operation with standard AC power
vertical mount applications. Equipped with the multi-media fiber/copper solutions,
and software alarms and convection cooling (no fans), the Magnum 6K16V easily
Magnum 6K16V has all of these, in a very sleek and robust metal case with a wide
with segments requiring Gigabit backbone interconnections, the Magnum 6K16V
qualifies for use in transportation and traffic control systems, power utilities and
additional details on the comprehensive set of software programs and options.
managed switches are easy to install and operate.
events through traps. See Section 3.5 for details.

Loaded with versatile management software (MNS-6K), the 6K16V switch can be easily
application the Magnum 6K16V is a finest solution to meet and satisfy those requirement
factory floor and office purpose solutions, the Magnum 6K16 can be mount side-by-side
on a 19” rack mount tray to provide the needs of port density. Equipped with three fan at
Dual LEDs on the front and the connector side help the vertically mounted 6K16V to be
bandwidth required applications. In a on-going demand of diversified designed Ethernet
The rack-mountable 6K16 model of 6K16-Series family, is a modular managed Carrier
The plug-n-play Magnum 6K16V managed fiber switch, should be mounted vertically
class Switch, which can be mounted horizontally as rack-mount, shown in the picture
feature of MNS-6K easily qualified this carrier class switch to meet any demands and
monitored easily. The modular designed Magnum 6K16V managed fiber switch can
by the rich modular structure. The Relay contacts for external “ALARM” is another
the rear, the fan-cooled Magnum 6K16, through its modular designed and diversified
The Multi-media (copper and fiber) support loaded with rich management
using the vertical mounting brackets which come with the unit or by using the DIN-
support of maximum four Gigabit modules (fiber or copper) to meet any demand of
additional feature which allows the Magnum 6K16V to monitor the internal power
Specially designed to cater the requirements for carrier class Telco applications or
support of 10/100 or 1000Mb speed can be a excellent gear for the carrier class and
choice of popular DC options or industry standard AC internal input.
failure and controlled via hardware or software trap control.
RAIL-KIT (optional) for Din rail mounting.
factory floor applications.
managed and monitored.
below.

monitoring of the switch through SNMP, but also protect the network through its security
features of port-security, SNMP3, VLAN etc. The redundant feature through STP, RSTP
single mode, combo of copper and fiber, and a diversification option to select 10Mb fiber
or 100Mb copper or 1000Mb copper/Fiber are some of the primary benefits, which allow
the Magnum 6K16 to fulfill all the demands and requirements of carrier-class, office and
and S-ring, LLL also allow to configure and control the switch as a fault tolerant device
The NEBS and ETSI compliant Magnum 6K16, rack mountable, and specially
The rich-choice of modules in various flavors of all fiber connectors, multi or
The Relay contacts for external “ALARM” is another additional feature which allow the
requirement of this space. Magnum 6K management features not only allow the easy
designed to support the popular DC options of (24VDC, -48VDC. AND 125VDC) as
well as AC input, easily qualify and make a popular and reliable contender for the
Magnum 6K16 to monitor the internal power failure and controlled via hardware or
carrier-class Telco and factory-floor applications.
or self-healing in a ring topology applications
factory-floor applications.
software traps.

6K8-MTRJ (to the left) and
MNS-6K Software Managed, preloaded Same
2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb
6K8-MLC or –SLC - (below)
Mounting Horizontal, Rack-mount Vertical, Din-Rail Panel
Module Model #s e.g 6KP8-RJ45 e.g 6KP8V-RJ45
LEDs Front, with ports Front and rear top
Fig.2.2.2 :
Cooling fan cooled, 3 fans Convection
Power input 24VDC/-48VDC/125VDC Same
Redundancy LLL, STP,RSTP, S-Ring Same
Alarm Contact Hardware & Software Same
Media Copper & Fiber Same
Port Module can be 10,100 or 1000Mb Same
Operation Plug-n-Play Same
Suitable for Applications Telco, Offic e, Industrial
or AC(Regular)
Controlled via
ACT
F/H
ACT
F/H
ACT
F/H
ACT
F/H
1 3 5 7
2 4 6 8 LK LK LK LK
Utility,Industrial,Outdoors
ACT
ACT
fiber
F/H
ACT
F/H
ACT
F/H

speed (100Mb), mode, and connector type. Models are available with Small Form Factor
selects a mode and speed to match the device at the other end of the twisted pair cable.
(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will
The 100Mb fiber eight-port modules for the Magnum 6K16-Series’s normally
F/H
ACT
F/H
ACT
F/H
ACT
F/H
There are three LED’s per fiber port. The Link (LK) LED indicates “ready for
Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK)
In an eight-port SFF fiber port module, all of the fiber ports are of the same
operation” on that port when lit, the F/H LED indicates operation in full-duplex mode
indicator for that port must be ON (indicating there is a powered-up device at the other
10/100Mb switched RJ-45 ports. The 10/100Mb switched ports normally (as a default
operation at 10 or 100Mb speed in full- or half-duplex mode, i.e., each independently
when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving
setting) are independently N-way auto-negotiating, and auto-crossover(MDIX) for
are set (factory default) to operate in full-duplex mode for best fiber distance and
end of the cable) in order for a LK LED to provide valid indications of operating
automatically determine the other side of connection to make the connection, and
(SFF) are multi-mode MT-RJ or LC-type connectors, and single-mode LC-type
The 6K8-Series’s 8-port Copper port module, model 6K8-RJ45, provides eight
2 4 6 8 LK LK LK L
1 3 5 7
AC
F/H
AC
F/H
AC
F/H
AC
F/H
eliminate the need of cross-over cable.
software, the user may select full- or
set-up of the software (See Magnum
HDX type of Fast Ethernet devices).
half-duplex mode per-port through
6K-MNS Software Manual) for the
performance. Using the 6K-MNS
flexibility to adapt to any FDX or
conditions on that port.
connectors.

port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port
into an RJ-45 port and the Link (LK) indicator for that port must be ON (indicating there
except they have capability of providing power on each port to power up the PD devices,
standard. The Power Pass-
totally dependent upon the
Maxm. one PoE modules
The PoE modules are also
On the model 6K8-RJ45 module, there are four LEDs for each port, two in the
connector and two separate. The LK (Link) LED indicates “ready for operation” on that
Using the 6K16-Series (MNS-6K) management software, the user may disable
auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb
The PoE (Power-pass-through) RJ-45 ports act similar to regular RJ-45 ports,
per the IEEE802.3af PoE
through PoE modules are
power supply to support
ports. Each port requires
atleast 15watts to power
can be configured in the
A, B slot of any 6K16 s
with -48vdc power input.
available with mix –n-match with fiber modules. Please check the ordering information
when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb

is a powered-up device at the other end of the cable) in order for a LK LED to provide
2.2.4 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8- port
up the PoE PD devices.
or 100Mb speed and full- or half-duplex mode per-port as per user requirement. (See
3 F/H POE
valid indications of operating conditions on that port.
Magnum MNS-6K Software Manual for details info.).
2 1 3 5
Sec.1.2 for all the various P6K PoE modules option.
4 FULL/HALF
2 4 6 F/ H POE
speed when OFF (when auto-
operation and OFF to indicate
pair cable must be connected
negotiation is not disabled).
The FDX/HDX LED is ON
half-duplex mode. A twisted
8 Port@ 10/100Mb Copper ports
LINK LK / ACT 2

The four RJ-45 ports operate just like the 8-port copper module with auto-cross
On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port,
which indicate status the same as described for the 6K8-RJ45 in Section 2.2.3 above. The
2@10Mb fiber mm ST ports, and with
4@ RJ45 10/100 copper and 2@10Mb
PoE LED is ON when connected properly to a 803.af compliant PD device on that port.
When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data
LINK and ACTIVITY LEDS are combined on the PoE modules into one LED
four 10/100 switched RJ-45 copper ports and two 100Mb switched multi-mode fiber ST,

(MDIX) feature to eliminate the use of cross-over cable, and the two fiber ports operate
at 100Mbps full-duplex (default). User mode control per port through the MNS software
fiber port’s LEDs indicate status the same way as described for the SFF fiber modules in
4@ MTRJ 100Mb mm SFF fiber and
4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half of
regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the
The combo six-port modules are combinations of copper and fiber media, available as
SC or single mode SC or Long Reach SC ports. For ports numbering, ports 1,3,5,7 are
The Magnum Combo six-
port modules are also available with
the module is as described for those port types above. For detailed information about
The LEDs on 6KP8-RJ45- PoE module are slightly different compared to
Section 2.2.2 above. Color-coding on the panel of the module shows which LEDs
fiber mm ST ports. The
copper, ports 2 and 6 are fiber, ports 4 and 8 are not present.
10Mb mm ST fiber half of the module, see Section 2.2.5.
that is marked as LINK/ACT, as shown in the diagram.
F/H ACT

1 3 5 7
traffic is not affected by PoE.
belong to which port.
F/H
is also the same.
ACT
F/H


choice for the modular slot. While up to two Gigabit modules (maxm.) can be configured
present, ports 3, 4. 7, 8 are not present. There is also a similar 100Mb fiber SC module.
Magnum 6K16-Series Switch to connect to any 10Mb hub or media converter or almost
The Magnum 6K16-Series offered a wide option Gigabit speed with multiple
RJ-45), whereas the single Gigabit module comes in flavor of G+4(10/100 RJ-45 ports)
1@ 1000Mb Fiber SC + 2@ 100Mb SC 1@ 1000Mb Fiber SC + 4@10/ 100Mb
The 4-port @10Mb ST fiber modules behave the same as the 4@100Mb ST
any other device with a 10Mb fiber Ethernet port. The default setting of 100Mb, fiber
The fiber ports support fiber cabling distances according to the 10BASE-FL
and 100BASE-FX standards, i.e., 2km distance for multi-mode fiber. (Single-mode for
different configuration. The two Giga port has been offered as GBPM-2OTX (fiber or
GBICs to provide Gigabit (Gb) media flexibility. GBIC models are available for both
multi-mode (550m) and single-mode (10, 25, 40, 70)km fiber options, and for Gigabit
The default setup on 10Mb, fiber module is half-duplex, which allows the
in the modular slot. The Gigabit port option for the modular slot comes in couple of
The 6K16-Series Modules provide a GBIC opening for insertion of industry-standard
fiber modules except for the 10Mb speed. For ports numbering, ports 1, 2, 5, 6 are
module is full duplex. User mode-control per port through the MNS “port settings”
1 3 5 7
up to greater distance may be available as a special order, request quote).
or G+2 (100Mb fiber ports) as shown below in the figure.
software is the same as the other 6K16-Series modules.
F/
2.2.7 Gigabit (1000Mbps) port modules
copper as well, with new models appearing often.
ACT
F/
TX RX L
TX RX LK
ACT
ACT
F/
F/


The Magnum 6K16-Series offered a wide selection of Gigabit speed with multiple choice
Gigabit transceivers covering a long range of distance. The GBPM-2OTX also meets the
requirement for those applications where a managed Gigabit media converter is required.
performance. The 1000Mbps SC fiber-optic module on the Gigabit -SX and Gigabit-LX
There are two LEDs mounted on each Gigabit port module. The Gigabit fiber has LEDs
configured in the modular slot for GBPM-2OTX. The Dual Gigabit port option for the

come in couple of different configuration to provide a wide option of choice of various
The 1000Mb Gigabit fiber-port modules on the Magnum 6K16-Series are
normally set (factory default) to operate at AUTO mode for best fiber distance and
that indicate LK (Link status) and ACT (receiving activity) on that port when lit.
The two Gigabit slot can be filled with copper/Fiber or mix as per the application.
transceivers are compatible with the IEEE 802.3z Gigabit standards.
2.2.7a GBPM-2OTX (Two Gigabit module option)

slot via GBPM-20TX module. While up to
of copper or Fiber or mix for the modular
two Gigabit modules (maxm.) can be
modular slot


The Gigabit ports are set by factory as AUTO by default but can be configured
6K16-Series can do its part to prevent any QOS degradation while it is handling Ethernet
priority tagged packets according to the 802.1p standard. In addition to hardware support
the eight levels of defined packet priorities for application-specific priority control by the
users from datagram paths that go all across a network. As a LAN device, the Magnum
for QOS, the MNS software (R2) supports two priority queues that can be shared across
Quality of Service means providing consistent predictable data delivery to
The Magnum 6K16-Series switching hardware supports the IEEE 802.1p
standard and fulfills its role in support of QOS, giving packet processing priority to
as per the convenience using the MNS-6K management firmware.
user through software configuration settings.
traffic through its ports and buffers.

When the Magnum 6K16-Series Switch detects that its free buffer queue space
control sequence occurs in a small fraction of a second and is transparent to an observer.
that its free buffer queue space is low, the Switch prevents more frames from entering by
Magnum 6K8-Series’s come with licensed MNS-6K Firmware (Rel 3.2), which
packet) is loaded into the Switch’s memory and inspected before forwarding can occur.
"express") impose minimal frame latency, they will also permit bad frames to propagate
out to the Ethernet segments connected. The "cut-through" technique permits collision
fragment frames (which are a result of late collisions) to be forwarded which add to the
network traffic. Since there is no way to filter frames with a bad CRC (the entire frame
collisions and bad packets are more likely when traffic is heavy, the result of store-and-
forward operation is that more bandwidth is available for good packets when the traffic
is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the
flow-control mechanism (when operating at half-duplex only). When the Switch detects
allows to configure the Magnum 6Ks as a Managed Switch and other Software enabled
features. For additional information about MNS-6K, see the Magnum 6K8-Series MNS
correct CRC, i.e., are good packets. This eliminates the propagation of bad packets,
dropping packets. Then, normal packet buffering and processing resumes. This flow-
Another feature implemented in Magnum 6K16-Series Switches is a collision-based
forcing a collision signal on all receiving half-duplex ports in order to stop incoming
Software User guide in pdf format, a separate document normally accessed via your
Magnum 6K16-Series’s are store-and-forward switches. Each frame (or
This technique ensures that all forwarded frames are of a valid length and have the
must be present in order for CRC to be calculated), the result of indiscriminate cut-
through forwarding is greater traffic congestion, especially at peak activity. Since
While other switching technologies (such as "cut-through" or
devices sending packets to cause “flow control”. This tells the sending devices to
temporarily stop sending traffic, which allows a traffic catch-up to occur without
enabling all of the available bandwidth to be used for valid information.
or FTP client program by ftp.GarrettCom.com using
web-browser, at ftp://ftp.garrettcom.com/
load is greatest.
traffic.

All MNS-6K software information, including new releases and upgrades related to MNS-
www.GarrettCom.com/techsupport/index.htm#software and look for Magnum
allow the basic and advanced info about the Magnum MNS-6K management software
Magnum MNS-6K Operator Training – This interactive training software
Alternatively, for documentation and latest information, or needed
6K software, can be accessed and download from GarrettCom’s FTP site.
or email: support@GarrettCom.com for further information.
and a useful tool for first time user.
MNS-6K info..

Magnum 6K16-Series Switches provide non-blocking (all ports can run at full speed at
They are typically used in LAN traffic centers with 16 100Mb or 8+2 Gigabit ports for
The Magnum 6K16-Series switching hardware supports QoS, giving packet processing
provides for this with heavy-duty components. The ambient temperature dual-rating is
Magnum 6K16-Series Managed Fiber Switches are designed to naturally include fiber
ports, and support mixes of multi-mode and single-mode; 10 Mb, 100Mb and 1000Mb
Relay Contacts for monitoring internal power and user-defined software events
signal loss of power internally. The other is software controllable and will signal user-
Mounting brackets for vertical mounting are included. DIN-Rail mounting hardware
is optional. Ethernet signal and power cables attach in the bottom. Two sets of status
applications, models with –48VDC or 24VDC or 125VDC are available. Dual Source
Release 2.5 (fall ’03) includes SNMP Switch Management with secure access control,
RMON, CLI, Port Security; Port Mirroring; Port Settings Control; Telnet, TFTP, FTP
software is factory installed, supported and updated via Internet and GCI FTP Server.
once) performance with standard Managed Networks Software (MNS-6K) included.
priority to priority tagged packets according to the IEEE 802.1p standard. For port-
Two Alarm Relay contacts monitor basic operations.. One is for hardware, and will
Heavy-duty design for Industrial Ethernet and extended temperature operation
Fiber ports take more power than copper ports, but the Magnum 6K16-Series design
support, Spanning Tree Protocol, Link-Loss-Learn, S-Ring (with license key) multi-
S-Ring and Link Loss Learn for reliable high availability using ring topology
S-Ring along with the Link-Loss-Learn feature provides reliable fast recovery of a
LEDs, one set viewable at the port connector and one set viewable from the front.
Standard AC power input is IEC plug, auto-ranging for worldwide use. For special
60`C per UL methods, and 95°C per type test methods.. MNS-6K licensed Network Management Software included, S-Ring optional
defined software events such as a security violation or an S-Ring fault condition.
Standard AC power input, -48VDC or 24VDC or 125VDC input is optional
support; Event Log; SNTP client for time-of-day; BootP and DHCP client for IP
and application-specific priorities of data, the QoS software may be configured.
connectors. RJ-45 10/100 ports can also be configured in the mix of port types.
Vertical mounting for efficient convection cooling, no fans, extended temp.
level QoS, Port- and tag-based VLANs, GVRP, IGMP Snooping, SNMPc GUI
configuring, and password security. Web management is in beta-test. MNS-6K
speed; full-and half-duplex; classic Small Form Factor (SFF) and GBIC fiber
DC input can also be selected and configured on the DC power input models.
backbone connections, where managed network services are desired.
Switching services includes 802.1p QoS packet prioritization
Managed switching for high performance Ethernet LANs
fault in a ring topology.
Features Fiber-Built-In

including client/server computing, secure VLAN- performance upgrades to departmental
networks, and stream traffic for VOIP and audio/video applications, or a very diversified
the Magnum 6K16, allow the Factory floor Industrial’s user to mount securely anywhere
Magnum 6K16-Series Fiber Switches offer high performance, modularity and
The mixed-media modular capability is ideal for Industrial applications where
fiber-built-in media capability is ideal for integrating future-proof fiber cabling into the
AC/DC power supply option, extended temperature rating qualifies the Magnum 6K16-
Series Managed switch, for any Industrial factory-floors, traffic control, transportations
features diversified this managed switch to operate and perform securely and reliably in
allow this Managed switch to provide a very secure highly available redundant network
Ethernet based mixed-media LANs, equipped with PLCs, computers for taking reading
MNS-6K management software features, remarkably handle these kind of network very
securely and reliably through out the Factory-floors. The DIN-Rail Mounting options on
availability. They provide the flexibility of 100Mbps fiber and copper ports as well as
subnets (one subnet per 6K16-Series Switch port) in a LAN traffic center. The subnet
connections may be via fiber or twisted pair cabling, 100Mbps or 10 Mbps speed, and
existing Ethernet LAN networks where existing cabling must be accommodated. The
and data from M/C, Client/ Server databases and fetching these important datas to the
software. Magnum 6K16-Series Switches are easily used in a variety of applications
systems and power utilities applications. The bundles of MNS-6K software operated
all critical applications. The addition of S-Ring and Link-Loss-Learn software feature
characteristic of the 6K16-Series Switches enables them to inter-connect a series of
Equipped with lots of useful features, hardened enclosure, wide spread of
In an Industrial environment where the factory floors are networked with
central office data warehouses. The Managed 6K16-Series’s modularity along with
single or dual Gigabit(1000Mb) ports, with industry-standard LAN management
combination of mixed media in Industrial floor applications.. The performance
capability in any ring topology network.
on their Network setup.
full-or half-duplex.
LAN structure.

be easily connected together with the Fiber ports supported by the Magnum 6K16-Series
Switch. A main NT-server in a secure area protected from earthquake or fire hazards can
Extended temp. ratings and wide options of AC/DC power supply qualifies this
long distance subnets and provide a stable secure network to all applications. The SNMP
management capability of the Magnum 6K16-Series Switch helps create a database of all
Example 2. In another application, a managed network is needed to provide a Redundant
The option for setting the ports at 10 or 100Mb on copper, and supporting the
Fiber Switch makes it an attractive choice for use in applications with LAN connections
to an organization’s multiple site offices and factory- floors. The different locations can
required to operate the network. Full-duplex future proof fiber media can easily connect

10 or 100Mb fiber media, provide a very widespread option to the users to mix match
their legacy and advance network needs. The modularity of the 6K16-Series Managed
managed 6K16-Series switch to use in temp. controlled network floor and many others
disconnection or power failure in a ring switch can be reconfigured the network up
temp sensitive critical Industrial applications, where above normal room temp. is
Fig. 2.4a- The Industrial factory floor application with Magnum 6K16-Series
ring topology for maximum redundant network, where any faulty cable or cable
the network subnets to easily manage the network.
be connected to the full duplex Gigabit Fiber port.
H
F/
H

check the status of other Ethernet units . The entire spread network will be manageable to
copper and fiber ports provides an economical and seamless solution to the requirements.
easily fulfilled the redundant requirement in a secured and faster reconfiguration time for
running in mili-seconds . The ring topology of the network consists of high speed LAN
segments supported by 100Mbps full-duplex future-proof fiber media to provide secure
requirements by providing copper/fiber media along with the higher bandwidth support
Gigabit-enabled data-mining server for the vital database located in a separate secured
The Magnum 6K16-Series Managed Fiber Switch equipped with the mix of
of 10/100 and 1000Mb. The user can utilize the SNMP feature equipped with VLAN,
RMON, STP and other standard managed LAN features to provide a secure and stable
building. The copper ports are required for multiple subnets inside the power plant to
The user-configurable Magnum 6K16-Series provides an extra boost to the network
The 6K16-Series Managed Fiber with S-ring and Link-Loss-Learn feature

provide easy, detectable, uninterrupted support through a viewable SNMP monitor.
cable breakup, by setting up in a ring topology. The Gigabit port option boosts the
long distance LAN connection. The entire network is sharing a higher bandwidth
bandwidth for high speed to support the peak traffic and minimize congestion.
2 4 6 8
A
A
CT
K
CT
F/
F/
H
H
T
K R
1 3 5 7
A
CT
F/
H
A
C F/
2 4 6 8
T
A
CT
K
F/
H
T
H
K R
1 3 5 7
1 3 5 7
2 4 6 8
CT
K
F/
H
C F/
H
2 6T X
H
R
A
C F/
H
T
K R
1 3 5 7
T
A
F/
H
network.

copper connection to store the sensitive datas. The switch must be snmp enabled
carrier-class space environment. Equipped with a rack mount solution to deploy
side-by-side, the carrier-class managed switches also provide the port density in
and secure solution can be met easily by Magnum 6K16s managed switches. He
Example 3. In another application, in a Telco environment, 12 port Nebs
compliant, -48VDC operated managed switch is required to meet the fiber and
MNS-6K, the 6K16 provides a very effective and economical solution for the
In a carrier class (Telco) environment the expected reliable
requirement with all the features and modularity. Loaded with management
reliable solution. The modularity feature to support both copper and fiber at
The security features e.g port-security, vlan, Snmpv3, secure telnet etc.also
boost the Magnum 6K16 managed switches to provide a very effective ad
either 10/100/1000Mb speed easily meet the variation speed of legacy and
copper/fiber and both configuration to meet heir requirement. The Gigabit
uplink for the storage or broadband uplink allows the telecom users a very
Magnum 6K16, managed carrier class switch easily qualifies for this
modular design of Magnum 6K16 provide a wide range of options of
effective solution to store their sensitive users data securely.
and managed to easily manage the whole setup.
future broadband requirement.
a rack-mounting space.

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment
2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate air flow must be maintained for proper and
3.) If the equipment is mounted in an enclosed or multiple rack system, placement of the equipment must not overload or load
4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent
of the intended Magnum 6K16-Series site. The rugged metal case of the Magnum 6K16-
individually selected and configured per-port. See Section 2.4 for a description
802.3, 802.3D, 802.3u, 802.3AB and 802.3z standards and connector types are as follows:
5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and
For AC power input, locate an AC receptacle that is within six feet (2 meters)
support all standard Ethernet media types within a single Switch unit. This is
This section describes installation of the Magnum 6K16-Series Switches, as
For DC power options, see Appendix B. For Dual Source, see Appendix C.
Maintain an open view of the front to visually monitor the status LEDs. Keep an open
Before installing the equipment, it is necessary to take the
Series will normally protect it from accidental damage in a lab or workplace setting.
electronics use the case as a heat sink, so the unit may normally be quite warm to the
The Magnum 6K16-Series Switches are specifically designed to
The various media types supported along with the corresponding IEEE
area around the unit so that cooling can occur from convection while the unit is in
operation. The 6K16-Series has no fans, so it is silent when in operation. Internal
accomplished by using a family of different port Modules which can be
For vertical panel mounting and wall mounting, see Section 3.4.
overloading of the building/s electrical circuits.
For vertical DIN-Rail mounting, see Section 3.3.
well as connection of the various Ethernet media types.
must be less than or equal to 500C.
touch.
uncompromised earthing path.
unevenly the rack system.
following precautions:
safe operation.
of the PMs.

10BASE-T and 100BASE-TX twisted pair 100m (328 ft) 6K8-RJ45
The following procedure applies to installations using a PM with SC-type fiber
dampened in alcohol. Make certain the connectors are clean before connecting.
connection has been established at both ends (and when power is ON in
The following procedure applies to installations using a PM with ST-type fiber
connectors. This procedure applies to ports using a 6K16-Series module, MST-
Receive (RX) port of the remote device. Begin with the color-coded strand of
(TX) port of the remote device. Use the non-color coded fiber strand for this.
improper cable polarity. Swap the fiber cables at the PM connector to
the unit). If LINK is not lit after cable connection, the normal cause is
When connecting fiber media to SC connectors, simply snap on the two square male
small form factor mm1 Fiber 2.0km (6,562 ft) 6K8-MTRJ, -MLC small form factor sgl.m1 Fiber 15 km 6KP8V- SLC
bands at regular intervals; you must use the color-coded strand on the
IEEE Standard Media Type Max. Distance Port Module
100BASE-FX mm1 Fiber 2.0km (6,562 ft) 6K6-MSC, -MST
sgl.m2 Fiber 5Km GBIC-LXSC
1 mm = multi-mode 2 sgl.m = single-mode
connectors into the SC female jacks of the 6KPM, until it clicks and secures.
sgl.m2 Fiber 18.0km (95K ft) SSC, SSCL
100BASE-FX mm1 Fiber 220m ( ft) GBIC-SXSC
3.2.1 Connecting Fiber Optic ST-type, “twist-lock”
associated ports at each end of the fiber optic segment.
3.2.2 Connecting Fiber Optic SC-type, "Snap-In"
connectors, i.e., using 6K-MSC, 6K-SSC single-mode.
the cable for this first TX-to-RX connection.
remedy this situation.
type port.
Fiber:

(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx
fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes
The RJ-45 ports of the Magnum 6K16-Series can be connected to the following
may be used. In either case, the maximum distance for unshielded twisted pair cabling is
mixed-speed network, since dual-speed ports are auto-sensing for either 10 and
could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)
1613specifications for zero packet loss with fiber ports & with RJ45 ports used as indicated here.
connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable
making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3
The following procedure describes how to connect a 10BASE-T or 100BASE-
are the diameters of the core and the core plus the cladding respectively). Single-mode
Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45
TX twisted pair segment to the RJ-45 port. The procedure is the same for both
telecommunication multiplexers installed in close proximity (i.e., less than 2
When using single-mode fiber cable, be sure to use single-mode fiber port
The same procedures as for multi-mode fiber, applies to single-mode fiber
meters or 6.5ft) to the 6K16(V). It is not recommended to use these ports in
substation applications to interface to field devices across distances which
Twisted Pair (CAT 5) 100BASE-TX RJ-45
and 100Mb) be used whenever possible in order to provide flexibility in a
advises that, for substation applications, the RJ-45 ports are intended for
illuminated when the unit is powered and proper connection is established
Media IEEE Standard Connector
shielded, either unshielded or shielded cables and wiring may be used.
connectivity to other communication equipment such as routers or
during line-to-ground fault conditions. The 6K16(V) passes the
connectors. Follow the steps listed in Section 3.2.2 above.
unshielded and shielded twisted pair cables.
up to 10 Km apart, or 18Km with the 6K-SSC.
100 meters (328 ft).
100Mb/s.

(STP) balanced cable is recommended to use when making 1000BASE-TX connections.
In either case, the max distance for unshielded twisted pair cabling is 100 meters (328 ft).
Mb and 1000Mb) be used whenever possible in order to provide flexibility in a
gigabit media type desired. A selection of fiber and copper GBICs are available.

See a 6K16V viewed from the rear, at right, with model DIN-RAIL-VRM in place on the
The RJ-45 Gigabit ports of the Magnum 6K16-Series can be connected to the
The following procedure describes how to connect a 1000BASE-T twisted pair segment
The Din Rail Latching clips are mounted on the upper rear
media types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair
to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted
(STP) balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair
The Gigabit ports accept industry-standard GBICs for user selection of the
corners of the 6K16V unit. Two threaded holes are
Media IEEE Standard Connector
Twisted Pair (CAT 5E) 1000BASE-T RJ-45
maintained vertically for proper convection cooling of
6K16V) The Magnum 6K16V is designed for use in
available with optional DIN-Rail brackets to mount it
the unit. The Magnum 6K16V requires two DIN-Rail
these may be ordered as Model # DIN-RAIL-VRM.
mounting clips or latches for secure mounting, and
a “factory floor” industrial environment. It is
securely in a metal factory floor enclosure,
cables and wiring may be used.
mixed-speed network.
pair cables.
unit.

To install the 6K16V with the DIN-Rail brackets and
latches attached to it, hold the 6K16V in the vertical position
DIN-Rail. Position the latches over the top of the DIN-Rail.
Then, snap the latches into holding position by moving the bottom of the 6K16V inwards
To release the 6K16V from the DIN-Rail mounting, press the top of the two DIN-
is not engaged and the 6K16V can be moved up and out, free of the DIN-Rail mounting..
from the rear of the panel by the mounting brackets. The 6K16V design uses the case for
Fig 3.3.1- Magnum 6K16V mounted
purposes. See side view at the left, with the top of the unit
are designed as if that they can be manually accessed from
Rail latches down simultaneously to release the 6K16V so that it can be dismounted by
pulling the bottom out. Once the bottom of the 6K16V is rotated out, the DIN-Rail latch
shows vertical mounting of Magnum 6K16V on a DIN-Rail track for proper convection
cooling of the unit. Note that there is air space in the rear, as the 6K16V unit is held out
provided on the sides of 6K16V for DIN-Rail mounting
pointed to the right. The required two screws are included
with the DIN-Rail brackets, and are no.10-32 X 3/8 PHIL.
PAN w/star washer. The two heavy duty Din-Rail latches
with the bottom out, and with the top moved in toward the
to a vertical position. The DIN-Rail latches and brackets are heavy duty, and will hold
The picture below is a front / right-side view of a DIN-Rail mounted 6K16V. It
cooling (patent pending), and needs to be mounted vertically with air flow space in the
the top when the 6K16V is installed on a DIN Rail.
the 6K16V securely in position, even with cabling attached to the unit.
front, rear, and sides.


vertically with DIN-Rail · brackets and latches

(patent pending) to move the heat generated by the electronic components inside into the
The unit can be mounted using the brackets turned outside (normal) or inside (if
for the mounting screws into the supporting wall or panel is a rectangle 11.89” x
The DIN-Rail mounting brackets and latches are optional and need to be ordered
Each Mangum 6K16V is supplied with metal mounting brackets and screws to
below, for proper cooling and long-life reliability. It is also advisable to mount the unit
creating a rear space of about ¼ inch or 1cm. This allows air circulation and cooling of
space is tight). Attach the mounting bracket either outside or inside as shown in
the illustration above (dotted line shown for the brackets inside). The spacing
mount the unit securely. It is recommended to mount the 6K16V vertically, as shown
with space for air movement around the top and the sides, typically a minimum of 1
the rear part of the case. Since the 6K16V uses special internal thermal techniques
case, the case may be quite warm to the touch during normal operation.
as separate items, e.g Model # DIN-RAIL-VRM
7.85” center-to-center.
inch..

K16-RMB Set of two rack-mount brackets for one 6K16 unit in a 19” RETMA 1U rack
provide the rack-mount support to the carrier class switch and filled the 19” RETMA 1U
The pro- carrier class Switch, Magnum 6K16 can be installed single, as it is being shown
Fig 3.3.2b- Two Magnum 6K16s deployed over a K16-2Tray side-by-side to provide
space, with screws to attach the metal mounting brackets to the case. Can add Model K16-
K16-2TRAY Rack mount tray fro holding two side-by-side 6K16’s in a 19” 1.5U rack

on the above Fig. 3.4a on the K16-2Tray. The empty slot on K16-2Tray can be filled as
per the requirement. Easy to install the K16-2Tray comes along with all the accessories
Magnum 6K16, a carrier class focused managed switch can be
K16-EXTN-KIT Kit of extender brackets for converting one K16-RMB or one K16-
to install securely and quickly. The 6K16 Switches are being installed side-by-
space, each 6K16 unit individually removable for service. Can add Model K16-EXTN-
The above mentioned rack-mount kits is being designed for Magnum 6K16 only to
rack space. The K16-EXTN-KIT is specially designed to meet the European Telco
mounted as rack-mount using the following kit options offered for this product –
side to provide a larger port density, is shown below in Fig 3.4b
Fig 3.3.2a- One Magnum 6K16 deployed over a K16-2Tray
EXTN-KIT to extend to ETSI and 23” rack width.
Standard (ETSI) 23” Telco rack requirement.
KIT to extend to ETSI and 23” rack width.
2TRAY to ETSI and/or to 23” Telco rack.
larger port density of 32 ports.

supply and have a recessed male IEC connector for the AC power cord at the left-rear. A
AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz.
Ethernet cabling, there is no need to power down the unit. Individual cable segments can
be connected or disconnected without concern for AC power-related problems or damage
The second (bottom position) NC Alarm Contact is held close when there is
The 16-port units will consume over 20 watts of power typically. When connecting the
Power supply options are available to suit the 6K16-Series Switches to special
high-availability communications and/or heavy industrial-grade applications, including:
3.5 Alarm Contacts for monitoring internal power, and Software Traps The Alarm Contacts feature, standard on Magnum 6K16-Series’s, provides
6K16’s case. The AC or DC power input connection is in the same panel. A manual On- Off Switch for power to the unit is not available on 6K16 units with the Alarm Contacts
The first NC Alarm Contact (top position) is a “Software Alarm”, operated
The Magnum 6K16-Series Switches incorporate an internal universal power
manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power
The auto-ranging power supply supports installation environments where the
See the Appendices of this manual for more details. Use an RFQ for other variations.

two Form C Normally Closed (NC) contacts to which the user can attach two sets of
status monitoring wires at the green terminal block. When this option is present, the
terminal block for Alarm Contacts is part of the Power Input panel in the Magnum
cord is supplied with each unit shipped within the United States and Canada.
3.4 Powering the Magnum 6K16-Series Managed Fiber Switch
* -48VDC, 24VDC and 125VDC with dual-source DC input,
option, as these two features occupy the same space in the case.
* -48VDC, 24VDC and 125VDC with single DC input,
by user settings in the MNS-6K software.
normal software operation. A user-defined
Trap or a Software Security violation or an
The user can disable the Software Alarm
Closed (NC) contact is held close during
command if desired. When the Software
Alarm is enabled, the Form C Normally
software malfunction, such as an SNMP
S-Ring Fault, causes the contact to open
and thus trigger an alarm in the user’s
feature with a software configuration
to the unit.
monitoring system

power on the main board inside of the 6K16. This provides a “Hardware Alarm” because
The Alarm Contacts are on the front left area (next to the DC power source)
Magnum 6K16-Series Switches are normally received from the factory with all
for an available front-mounted slot must be removed. The following procedure describes
viewing for the vertical-mount 6K16-Series model. The modules have the letter “V” in
the model numbers, but otherwise are the same. In the Port Module materials below, all
required 6KPM modules installed. There may be situations where 6KPM cards need to
be added or replaced. In cases where additional 6KPM cards are needed, the faceplate
the NC contacts will open when internal power is lost, either from an external power
those used in rack-mount 6K units, except that the top LEDs are positioned for front
down condition or by the failure of the power supply inside of the Magnum 6K16
equipment) are sensitive to static discharge. Use proper ESD measures when
of the Magnum 6K16-Series unit and is green in color as shown in the picture.
modules are referred to as “6KPM” for convenience in describing port module
reference the Magnum MNS-6K Software User Manual. (Chapter 19th).
Failure to do so may result in damage to the unit
from the chassis before attempting to remove
3.6.1 Preparation for Installing and Removing 6KPMs
Be sure the power cord is unplugged
and/or replace any PM cards.
and will void the warranty.
Switch. Useful info. about Alarm contacts:
handling port modules.
this operation.
installation.

contains (Daughterboard (Bigger) and Granddaughter board (smaller), three 5/8

stand offs for Granddaughter board, 6 standoff for daughter Board, nine #4-40
faceplate package includes 2 retainer brackets and four #2-56 flat head screws.
mixed with other Fiber combo 6KPM card packages. Always install the PM

properly. Each 6KPM Card package except the Gigabit, for field installation
Pan-Head screws along with Front panel face plate package. The Front panel
Granddaughter board. The copper 6KPM card should not work properly if
module separately one by one to avoid the mixing. Do not change the Blue
screws. Once these screws are removed, the front panel is easily slid out to the front of
color DIP Switch setting ever, and leave it at factory default.
towards the front side, as shown in the picture.
Once the front panel is removed, the
unit. Hold on the back part and then carefully
front cover may be slid out to the front of the
and slowly slide out the top chassis cover
and rear parts and assembled together
screws. There are 6 screws located on
the unit (6 each on the bottom side of
chassis consists of top-bottom, front
the front panel of the unit (2 each on
the side), 12 for top-bottom cover of
sides and 6 screws for the rear panel
top and the bottom and one each at
the unit) and 6 screws each on the
(2 each on top and bott0m and one
each on the side). Remove these
with the help of 18 Philips-head
disturb the power supply.
the chassis base.
The Magnum 6K16-Series · from the unit

main board along with four stand-off’s for each 6KPM card position. (See Figure 3.6.1b)
There are two PM slots (A, B) located on the front of the chassis cover. Looking into the
individual 6KPM cards screen plate which can be subjected to significant forces from the
stand off (female) provided at the front of
only four of the screws as shown in Fig. below. These screws are also used to secure the
Up to two front-mounted 6KPM cards may be installed in one Magnum 6K16-
Fig 3.6.2b Granddaughter Board placed in slot
individual PM installation spaces and female latch (white) connectors provided on the
vertical placed Chassis cover of the unit, there are three brackets with retaining screws
shown in the picture below are used to secure a PM face plate in position, but unscrew
Granddaughter board The 5/16 stand off has been used to place the daughter
(#256 flat head ) which hold each PM Face plate card slot securely. These six screws

Series Managed Fiber Switch unit. Follow these steps to install a 6KPM.
screw down tightly with the three 5/16 stand-off (male) on the top of the
When the chassis top cover has been removed, the interior of the unit is
exposed. Looking down into the Magnum 6K16-Series unit, notice that there are

the 6K16-Series Main Board and
Fig 3.6.2a Granddaughter Board shown
A & secured with three 5/16 stand-off’s
board on the top of the granddaughter board and latch it securely.
3.6.2b) on the chassis built in
(as shown in fig. 3.6.2a and
attached cables. (See Figure 3.6.1c)
See procedure in Section 3.6.1

above.
above.
separately

Fig. 3.6.2c Daughter Board, top view of

Fig 3.6.2d Daughter Board shown upside down with two male latch connectors
daughter board aligned with the bottom female connector for the installation
4 copper 10/100 ports

6KPM card fits into the space provided on the main board.

placed at the bottom of
the daughter board with
connector placed on the
main board. As shown
below in Fig. 3.6.2e
Fig. 3.6.2e Magnum 6KPM


#256 flat head screws. The brackets and screws have been installed inside of the
cooling air flow, safety, and operation as required by FCC, CE, and other regulations.
Magnum 6K16-Series.
6KPM Module installed inside
screen plates need to be placed on the front of the chassis cover to complete the
be operational. When leaving 6KPM slots empty, always use a face plate (Magnum
daughter board securely. The figure below shows the top view of 6KPM card
done, the front panel
along with the package of port module separately along with 3 brackets and 6
6K8-BLNK) to cover the slot opening in the front panel. This will maintain proper
installation process for that port module. The front panel screen plate comes
Fig. 3.6.2g Top View :

slowly and firmly with two
properly and the mounting
fingers (as shown below in
Fig. 3.6.2f) on the top of
holes are aligned with
stand offs then press
latched up securely.
top cover.



If another 6KPM card is replacing the one that has been removed, follow the steps as
slots), the chassis cover should be replaced. Make sure the chassis cover is
To properly remove a 6KPM card from the 6K16-Series Managed Fiber
described for installing a 6KPM card discussed in Section 3.7.1.
aligned properly before securing the enclosure.
the chassis. The screen faceplate screws out from
the inside front of the chassis cover by loosening
On the top of the daughter module there are six
standoffs holding the Granddaughter board with
the 4 screws and bracket while holding it down
position (see Figure 3.6.3a). Remove the three
Switch, follow the 3 steps below.
retaining screws for each 6KPM card. These
screws are used to secure a 6KPM card in
the board near the latch-up connectors as
slot is to remain unused, be sure to install
out the daughter board from the latching
connectors, using both hands, gripping
shown in Fig. 3.6.3b . If the now empty
Carefully and gently pull
a 6KPM-BLNK face plate cover.
Card

Use a DB-9 “null modem” cable (use on any serial port)or “one DB-9 and one
Switches, please follow the “Quick Step Guide” come along with the Switch.
Magnum 6K16-Series Switch configuration for Network Management, please refer to
The above information enables a management station ( a PC or Console terminal)
Switch) to the your PC, so that your PC becomes the 6K16-Series’s Console
Terminal. For Hyper terminal configuration to communicate with 6K-Series
Magnum 6K16-Series Software Manual available on GarrettCom‘s FTP site. Please
3.7.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.
Magnum6K16-Series Console Port (the RS-232 port on the 6K16-Series
to connect directly to the Switch Console using a straight-through serial cable.
http://garrettcom.com/techsupport/software/6k25_quickstepsrel2.pdf
1 CD Carrier detect (not used)
3 TXD Transmit Data (output)
USB” ( USB port on the laptop) null modem cable to connect the
2 RXD Receive Data (input)

with the 6K16-Series unit. They are not “bundled” with the unit.
Fig 3.7 Enlarged view of Magnum 6K16-Series Console Port area
5 GND Signal Ground
refer Section 2.2.9 of this manual for download information.
4 open not used
6-9 open not used
Pin 1 Pin 5
DB-9 (Console port connector)
Com.
Pin Signal Description · (DB-9) Port · Console

intended for temporary connectivity to other equipment such as PCs. Since the
This chapter describes the functions and operation of the Magnum 6K16-Series
A Magnum 6K16-Series provides switched connectivity at Ethernet wire-speed
Each time a packet arrives on one of the switched ports, the decision is taken to
either filter or to forward the packet. Packets whose source and destination addresses are
on the same port segment will be filtered, constraining them to that one port and relieving
is on another port segment will be forwarded to the appropriate port, and will not be sent
The Magnum 6K16-Series Switches operate in the store-and-forward switching
among all of its ports. The Magnum 6K16-Series supports10/100Mbs for copper media
Magnum 6K16-Series, but local traffic on a port will not consume any of the bandwidth
100Mbps selection for the switched ports must be configured through MNS software per
the rest of the network from having to process them. A packet whose destination address
mode, which eliminates bad packets and enables peak performance to be achieved when
console port connection is temporary, it is excluded from IEEE 1613 packet-
utilization and network performance. All ports can communicate to all other ports in a
Magnum 6K16-Series units are plug-and-play devices. There is no software
configuring necessary to be done for basic operation at installation or for maintenance.
(resides inside the unit) on the 6K8-RJ45. Optional Half / Full duplex mode and 10 or
advises that, for substation applications, the serial RJ-45console ports are
The only hardware configuration settings are user options for an UP-LINK Switch
and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth
unit as per the requirement. The internal functions of both are described below.
interrupted operation of the network (such as occasional multi-cast packets) are
to the other ports where it is not needed. Traffic needed for maintaining the un-
loss testing per the 1613 standard-defined test procedure.
there is heavy traffic on the network.
forwarded to all ports.
Switch.
on any other port.
Filtering and Forwarding

PWR : Power LED, ON when external power is applied to the unit.
ACT : ON with port activity for 10 Mbps and 100Mbps operation.
to be cascaded (X) to a 10/100Mb repeater or switching hub in the network. The Up-link
An address-aging algorithm causes least-used addresses to fall out in favor of
LK : Steady ON, Link status for 10 Mbps and 100Mbps operation.
next to the 10/100Mb (6K8-RJ45) port # 1 which it controls. It enables the port’s cable
Switch position is configured as (=) straight position by default from the factory settings
The Managed 6K16-Series Fast Ethernet copper ports, can be set for either fixed 100Mb
selection is made via MNS software. The factory default setting is for auto-negotiation.
At 10Mb or 100Mb-fixed speed, the user may select half- or full-duplex mode by MNS
100/10 : Speed LED, ON when the speed is 100Mbps , OFF when the speed is 10 Mbps
The module has a manual Up-link switch, located on the inside of the board
addresses suitable for use in larger networks. They are self-learning, so as nodes are
The RJ-45 ports independently support auto-cross (MDI or MDIX) in
converter) or fixed mode at 10Mb or 100Mb Half/Full Duplex(managed switch). No
Software for each RJ-45 port separately. For detail information See Section (10.1 at
All Magnum 6K16-Series units have address table capacities of 4K node
frequently-used addresses. To reset the address buffer, cycle power down-and-up.
auto-negotiation mode and will work properly with all the other connected devices
with RJ-45 port whether it supports Auto-negotiation or not (e.g 10Mb Hub, media
speed or for 10/100 F/H N-way auto-negotiation per the IEEE802.3u standard. The
page no.52) of this manual to access the “6K-MNS(Rel 3) Software user guide”
added, removed or moved from one segment to another, the 6K16-Series Switch
4.4 Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports
cross-over cable is required while using the 6K8’s copper port to other devices.
on all the RJ-45 ports, either used for all copper module or combo module.
For Magnum 6K16-Series models (6K16/6K16V) :
Operation is according to the IEEE 802.3u standard.
automatically keeps up with node locations.
OFF for half duplex.
Address Learning

One frequently-used application for the Managed Magnum 6K16-Series Switch
copper ports is to connect one of them using a fiber media converter to another Switch in
desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode
and are connected to another auto-negotiating device, there are 4 different speed and F/H
modes possible depending on what the other device supports. These are: (1) 100Mb full-
The auto-negotiation logic will attempt to operate in descending order and will normally
mode” result can change at any time depending on network changes that may occur). If
6K16-Series Switch’s RJ-45 ports handle this situation by configuring the ports as per
When Magnum 6K16-Series RJ-45 copper ports are set for auto-negotiation
arrive at the highest order mode that both devices can support at that time. (Since auto-
the device at the other end is not an auto-negotiating device, the 6K16-Series’s RJ-45
ports will try to detect its idle signal to determine 10 or 100 speed, and will default to
-- the devices at both ends of the cable are capable of operation at either 10
depending on the capabilities of the remote device. Standard commercially available
Fast Ethernet media converters mostly do not support auto-negotiation properly, and
require that the switched port to which they are connected be at 100Mb fixed speed.
desire through MNS software port settings and can check the port status of each port
negotiation is potentially an externally controlled process, the original “highest order
Auto-negotiation per-port for 802.3u-compliant switches occurs when:
Attachment to 10/100 auto-negotiation ports typically will not work properly. The
duplex, (2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.
-- the second of the two connected devices is powered up*, i.e., when
the network backbone, or to some other remote 100Mb device. In this case, it is
-- the LINK is re-established on a port after being lost temporarily.
Mb or 100Mb speed and/or in full- or half-duplex mode, and can
send/receive auto-negotiation pulses, and . . .
half-duplex at that speed per the IEEE standard.
LINK is established for a port, or
after the change.
General information -

may be limited within that collision domain. The Path Delay Value (PDV) bit-times must
Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.
Full-Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long
attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.
port for sufficient time to let the Switch reduce the buffer space used. When the available
back-pressure algorithm on 10/100 Mb ports for flow control. That is, the switch prevents
frames from entering the device by forcing a collision indication on the half-duplex ports
account for all devices and cable lengths within that domain. For Magnum 6K16-Series
burst of activity causes the switch to save frames until its buffer memory is full. This is
blocking) on Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted
The transmitting device is commanded to stop transmitting into the 6K16-Series Switch
that are receiving. This temporary “collision” delay allows the available buffer space to
When operating in 100Mb half-duplex mode, cable distances and hop-counts
to the sender when the packet buffer is nearly filled and there is danger of lost packets.
Receiver Sensitivity and Transmitter Power are the parameters necessary to
that they are in is powered up. These are exceptions to the “negotiate at
Magnum 6K16-Series Switches incorporate a flow-control mechanism for
most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the
transmitter to start sending the packets. Of course, the transmitting device must also
Magnum 6K16-Series Switches implement the 802.3x flow control (non-
support the 802.3x flow control standard in order to communicate properly during
compute the power budget. To calculate the power budget of different fiber media
10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are
free-buffer queue increases, the Switch will send a “RESUME" packet to tell the
LINK – enabled” rule above, but may be occasionally encountered.
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
installations using Magnum products, the following equations should be used:
improve as the switch catches up with the traffic flow.
OPB (Optical Power Budget) = PT(min) - PR(min)
normal operation.


and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25)
and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)
Lucent’) web sites and catalogs to provide guidance to network designers and installers.
mode 18+ (0.4) 1300 9/125 -15 -31 14 28 17.5 35
mode 40 (0.4) 1300 9/125 -5 -34 29 58 32.5 65
mode 2 (0.4) 1300 62.5/125 -19 -31 12 4 16 5.7
Mode 15+ (0.4) 1310 9/125 -15 -28 11 22 - -
1000Mb Multi- mode 0.55 1300 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4
1000Mb Single- mode 10 1300 9/125 -9.5 -20 8.5 17 10.5 21
1000Mb Single- mode 25 1550 9/125 -4.0 -21 15 37.5 17.5 43
1000Mb Single- mode 40 1550 9/125 -4.0 -21 15 60 17.5 70
1000Mb Single- mode 70 1550 9/125 -3.0 -23 18 90 20.5 102
The following data has been collected from component manufacturer’s (Agilent’s and
where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
SXSC
LXSC10
LXSC25
ZXSC40
ZXSC70
GBIC-
GBIC-
GBIC-
GBIC-
GBIC-

Remove the 6K16-Series PM(s) from the shipping container. Be sure
Series Switches have dual-speed capability for copper ports, the 2, 4, 6 or 8-port
interfaces are designed to support all standard Ethernet media types at 10 or 100
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only
This section applies only to PMs shipped as separate items, i.e., 6K16/6K16V
occurred during shipment or delivery. Inspect the contents of this package for
5.2 6KPM Module Description An important feature of the Magnum 6K16-Series is the use of Port Modules for flexible
connecting Ethernet media segments with all similar or combo connector type.
full-duplex (factory default) setting for 100Mbps fiber ports must be used,
contact your supplier. If you need to return the unit, use the original shipping
mixed-media connectivity to RJ-45 and fiber media. Since the Magnum 6K16-
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
installing a 6K16/6K16V PM; notify the carrier of any damage you believe
any signs of damage and ensure that the items listed below are included.
separately at a later date. In the event there are items missing or damaged,
This chapter describes each Port Module (PM), including appearance,
Examine the shipping container for obvious damage prior to
to keep the shipping container should you need to ship any of the PMs
container if possible. Refer to Chapter 5 for specific return procedures.
or 1000Mps speed. Each 6K16-Series PM provides a wide selection of
1 or more 6K16-Series (6K16 or 6K16V) PMs
PMs not factory installed in a Magnum 6K16/6K16V PM slot.
Installation instructions, with illustrations
if the following factors are both applied:
functionality, and status displays.
This package should contain:
passive Attenuation.
and

RJ-45 ports or used for COMBO module is set as (=) other user ports.
compared to 6K16 but addressed as e.g 6KP8V-RJ45 . For a correct list of
10/100Mbps and fiber optic ports at 100MB. The Combo module is equipped with dual-
port supports fiber optic cable distances up the IEEE-standard 100Mbps distance limits,
Link (LK) LED that indicates proper connectivity with the remote device when lit, and
The 6KP6-RJ10ST is a six port combo module that looks similar to
The ST-connector functions as a fiber optic transceiver to support 10BASE-FX network
supports the standard distance 100m on each port and the fiber port supports fiber optic
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The
the 100Mb combo module with the exception of 10Mb speed at the ST fiber module.
segments. When installed in a Magnum 6K16-Series Managed Switch, the copper port
Each port has an Activity (ACT) LED indicating packets being received, a
Each 6K16-Series PM is individually described in the following sections.
10/100 LED indicates the speed, if the LED is ON 100Mbps if it is OFF 10Mbps.
4 Port@ 10/100Mbps and 2 @100 Mb ST Fiber Port
The Magnum 6KP6-RJMST is a combo 6 port module of RJ-45’s at
F/H ACT
4 FULL/HALF
2 6 TX RX TX LK RX LK
6K16/6K16V Port Module types, refer to Section 1.2
1 3 5 7
ACT
F/H
LINK 2
i.e., typically 2km at full-duplex and 412m at half-duplex.
ACT
F/H
100m on each port and the fiber
mode ST-type connectors and
segments. When installed in a
supports the standard distance
dual speed copper ports. The
ST-connector functions as a
fiber optic transceiver to
Switch, the copper port
10/100 · support 100BASE-FX network · Magnum 6K16-Series Managed


hub to connect to the switch through 10Mb fiber ports. It supports distances according to
cable distances up the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full-
Link (LK) LED that indicates proper connectivity with the remote device when lit, and
the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km
received, a Link (LK) LED indicating proper connectivity with the remote device when
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The
Each port has an Activity (ACT) LED indicating packets being received, a
10/100 LED indicates the speed, if the LED is ON, 100Mbps if it is OFF, 10Mbps.
Each port has an Activity (ACT) LED indicating packets being
TX RX LK
RX
4 Port@ 10Mb ST Fiber Port
4 Port@ 10Mb ST Fiber Port
Series switch. They also provide a convenient way for the half duplex
6KP4-RJ10MST,
2 6 T
ACT
F/H
ACT
F/H
FULL/HALF
TX RX LK
TX RX LK
ACT
F/H
ACT
F/H
distance may be available as a special order).
their legacy 10Mb network
when lit (or half-duplex if
2@100Mb multi-mode FX-ST “twist lock”
FLSTFX is a combo fiber
Fiber ports. All four fiber
and configured as 10Mb
The 10Mb ST-fiber ports
allow the user to connect
lit, and FDX/HDX LED
duplex and half-duplex.
is a 10Mb multi-mode
fiber module with 4 ST-
ports are ST connectors
Half-duplex by default.
to the Magnum 6K16-
off).
The Magnum 6KP4-F10ST · indicating full-duplex mode · The Magnum 6KP4-

While the functionality of these two modules is essentially the same, the 6KP6-
Fiber ports. All four fiber ports are ST connectors and configured as 10Mb Half-duplex
Series switch. They also provide a convenient way for the half duplex hub to connect to
received, a Link (LK) LED indicating proper connectivity with the remote device when
by default for 10Mb fiber and 100Mb Full duplex for the 100Mb fiber. The 10Mb ST-
fiber ports allow the user to connect their legacy 10Mb network to the Magnum 6K16-
module with two 10Mb + two 100Mb multi-mode fiber module and in combine 4 ST-
the switch through 10Mb fiber ports. Whereas the 100Mb ST fiber module, allow to
connect the 100Mb demand of Switch devices. It supports distances according to the
10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km
lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).
Each port has an Activity (ACT) LED indicating packets being
RJMSC is equipped with an SC-type "snap-in" connector instead of an ST-type.
4 FULL/HALF
10/100 LK
2 6 TX RX TX LK RX LK
1 3 5 7
FDX / HDX and 10/100 operation, and the same face-plate lettering.
F/H ACT
F/H
LINK 2
ACTIVITY
ACT
distance may be available as a special order).
transceivers all in one module. This
is similar to the 6K6-RJMST. It has
module equipped with 4 10/100Mb
RJMSC is also a Combo 6 Port
RJ-45 ports along with 2 multi-
the same LEDs indicating port
activity (ACT), Link (LK), and
mode 100Mbps fiber optic
10/100 · The Magnum 6KP6-

Link (LK) LED that indicates proper connectivity with the remote device when lit, and a
ports and 2 Single-mode (Long Reach) SC-type connectors. It provides a combination of
The 6KP6-RJSSC, when installed in a Magnum 6K16-Series Switch operates
The Magnum 6KP6-RJSSC is also a Combo module equipped with 4 dual speed copper
copper and Fiber functions in one module to the 6K16-Series Switches, supporting four
module of the 6K16-Series Switch supporting four Copper and two single-mode fiber
on copper at the 100m distance. The Fiber is single-mode and cable lengths can be as
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The
distinguish the single-mode 6 K6-RJSSC from the multi-mode 6K6-RJMSC, the label
Link (LK) LED indicating proper connectivity with the remote device when lit, and a
Each port has an Activity (ACT) LED indicating packets being received, a
Each port has an Activity (ACT) LED indicating packets being received, a
10/100 LED indicates 100Mbps speed when lit and at 10Mbps speed when off. To
5.2.4 6KP6-RJSSCL 4 @ 10/100 Mb copper port and 2@100Mbps single-mode FX-SC-type, “snap-in” connector
The 6KP6-RJSSC, when installed in a Magnum 6K16-Series Switch has
copper supporting the 100m distance and Fiber supporting single-mode fiber cable
4 Port@ 10/100Mbps and 2 @100 Mb SSC Fiber Port
10/100 LK
F/H ACT
2 6 TX RX TX LK RX LK
Copper and two single-mode (Long-Reach) fiber network segments.
1 3 5 7
lengths of as much as 40+ Km (see Power Budget, Section 4.5)
F/H
“Sgl. M.” is at the top of the faceplate of the 6K6-RJSSC.
ACTIVITY
much as 25+ Km (see Power Budget, Section 4.5)
F/H
equipped with 4 dual speed
mode SC-type connectors. It
copper ports and 2 Single-
and Fiber functions in one
is also a Combo module
network segments.
connector

The Magnum 6KP6-RJ10ST is also a Combo module equipped with 4 dual speed copper
Magnum 6KP8-MTRJ is a multi-mode fiber optic 8-port module equipped with
The functionality of this 100BASE-FX multi-mode 8 Port module is essentially
10/100 LED indicates the speed for the copper port, which is 100Mbps when the LED is
5.2.4a 6KP6-RJ10ST 4 @ 10/100 Mb copper port and 2@10Mbps multi- mode FL-ST-type, “twist-lock” connector
copper and Fiber functions in one module to the 6K16-Series Switches, supporting four
copper supporting the 100m distance and Fiber supporting multi-mode fiber cable allow
the same as the ST and SC-types. It has the same LEDs per port indicating port activity
ports and 2 multi-mode 10 Mb fiber ST-type connectors. It provides a combination of
proper connectivity with the remote device when lit, and a FDX/HDX LED indicating
speed for the copper port, which is 10Mbps when the LED is ON and 10 Mb when the
FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The
to connect the legacy network of 10Mb requirement in the network. Each port has an
Activity (ACT) LED indicating packets being received, a Link (LK) LED indicating
The 6KP6-RJ10ST, when installed in a Magnum 6K16-Series Switch has
full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the
“small-form-factor”
ACT
F/H
ACT
F/H
ACT
F/H
ACT
F/H
F/H LK LK LK LK
1 3 5 7
6KP8-MTRJ,
Copper and two 10Mb of ST fiber network segments.
typically 2km at full-duplex and 412m at half-duplex.
ACT
F/H
ACT
ACT
ACT
F/H
F/H
ON and 10 Mb, when the LED is OFF.
an RJ-45 port, but it is black in
and ease of connection make it
connectivity. When installed in
a Magnum 6K16-Series Switch,
distances up the IEEE-standard
connector. It looks almost like
color. The MT-RJ’s small size
100Mbps distance limits, i.e.,
a good choice for 100Mbps
it supports fiber optic cable
LED is OFF.
a small-form-factor MTRJ-type · “fiber-to-the-desktop” Ethernet

with two different speeds. The top four ports of MTRJ Small form factor fiber support at
When installed in a Magnum 6K16-Series Switch, the 100Mb MTRJ connector
The 6KP6-RJ10ST is a combo module with two different kinds of fiber flavor
Fiber connector supports the standard fiber optic distance limit of 2Km at Full and Half-
5.2.5a 6KP6-MT10ST, 4 @100Mb multi-mode FX , MTRJ Small-Form- Factor and 2@ 10Mb Multi-mode ST-Fiber port
100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb half-duplex. This combo module provides more flexibility to the user to connect their
supports fiber optic cable distances up to the IEEE-standard 100Mbps distance limits,
i.e., typically 2km at full-duplex and 412m at half-duplex. The 10Mb Multi-mode ST-
The functionality of this 100BASE-FX multi-mode 4 port module is
4 Port@ 10/100Mbps & 4 port @ 100Mbps
4 FULL/HALF
essentially the same as the ST and SC-types. It has the same LEDs per port
indicating port activity (ACT), Link (LK), and FDX or HDX operation
F/H
ACT
F/H
legacy 10Mb fiber as well as 100Mb to the Magnum 6K16-Series Switch.
1 3 5 7
standard distances as mentioned on 5.2.3. and the LEDs also act similarly.
LINK 2
ACTIVITY
ACT
F/H
ACT
F/H
(ACT), Link (LK), and FDX or HDX operation.
copper and fiber (Small Form Factor)
equipped with 4 10/100 RJ-45 ports
MTRJ type ports. The small size of
advantage of placing more ports on
When installed in a Magnum 6K16-
Module is a combo module with
one module. The 6KP8-45MT is
MTRJ connectors provides an
Series Switch, it supports the
and 4 MTRJ fiber ports.
duplex both.
10/100 · Multi-Mode Fiber port · The Magnum 6KP8-45MT

LC type ports. The small size
Magnum 6KP8-MLC is a eight-
When installed in a Magnum 6K16-Series
indicating packets being received, a Link (LK) LED indicating proper connectivity with
the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit
combination of copper and
of LC connectors allows an
100Mbps distance limits, i.e., typically
wiring closets while providing the advantage of “future-proof” fiber optic technology.
The cable end is a “plug-in” connector with both fiber strands terminated in
one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED
Fiber (Small Form Factor)
advantage of having more
“small-form-factor” used primarily in
The compact size of the LC Connector reduces the size of wiring panels in
6KP8-45LC Module is a
port multi-mode fiber LC connector
100Mbps fiber-to-the-desktop links.
Switch, it supports fiber optic cable
2km at full-duplex and 412m at half-
distances up to the IEEE-standard
combo module with a
3 2 4 6 LK LK LK
4 FULL/HALF
4 Port@ 10/100Mbps & 4 port @ 100Mbps

F/H
ACT
F/H
8Port@ 100Mbps multi-mode LC fiber port
LINK 2
Multi - Mod LC Fiber port
(or half-duplex when off).
F/H
AC
F/H
AC
duplex.
The Magnum · 10/10

standard length. It is equipped with an eight-port RJ-45 connector, and offers 10/100 full
eliminates the need for a special twisted pair crossover cable when connecting to a hub or
Auto-crossover (MDIX), which allow the RJ-45 ports to automatically Link with any RJ-
could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)
1613specifications for zero packet loss with fiber ports & with RJ45 ports used as indicated here.
ports on one module. The 6KP8-45LC is equipped with 4 10/100 RJ-45 ports and 4 LC (
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a
When installed in a Magnum 6K16-Series Switch, it supports the standard distances as
telecommunication multiplexers installed in close proximity (i.e., less than 2
Each port has an Activity (ACT) LED indicating packets being received, a
Link (LK) LED that indicates proper connectivity with the remote device when lit, a
meters or 6.5ft) to the 6K16(V). It is not recommended to use these ports in
substation applications to interface to field devices across distances which
advises that, for substation applications, the RJ-45 ports are intended for
5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port The 6KP8-RJ45 module supports Ethernet twisted pair segments of any
(MDI-X) switch, which controls all ports for cascaded connection. This feature
per mentioned on 5.2.8. and the LEDs also acts similarly as mentioned above.
connectivity to other communication equipment such as routers or
10/100 LK
during line-to-ground fault conditions. The 6K16(V) passes the
8 Port@ 10/100Mb Copper ports
1 3 5 7
“10/100” LED indicating 100Mb when lit (or 10 Mbps when off).
LINK 2
ACTIVITY
45 device and eliminate the use of cross-over cable.
Small form factor) multi-mode fiber ports.
minimize emissions and will
shielded twisted pair (STP)
connector is shielded to
twisted pair (UTP) and
cable connections. The
6KP8-RJ45 module is equipped with a Media
each port. The RJ-45
another switch.

15watts to power up the PoE PD devices. In this
ports are enhanced with
POE option The 8-RJ45
devices. The PoE LED is ON when the attached PD is drawing power from the
5.2.10 New PoE(Power Pass-through), model P6KP8V-RJ45 (MDIX), 10/100Mb
input power supply to
POE module are also available with mix –n-match with fiber modules. Please check the
PoE LED is ON when connected properly to a 803.af compliant PD device on that port.
When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data
LINK and ACTIVITY LEDS are combined on the PoE modules into one LED
standard. The Power
(10/100) ports. Each
regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the
Fig. the top 8-RJ45
6 Port@10/10Mbps & 2 port @100Mb Multi-Mode Fiber port
The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have
IEEE802.3af PoE
The LEDs on 6KP8-RJ45- PoE module are slightly different compared to
capability of providing power on each port to power up the PD devices, per the
F/H
ACT
F/H
ordering information Sec.1.2 for all the various P6K PoE modules option.
ports with PD devices connected (up to 15 watts per PoE port).
6KP8V6KP8-45-2MT
ACTIVITY

that is marked as LINK/ACT, as shown in the diagram.
connected, the PoE port will
6K’s with 48VDC power input act as a pass-through,
so the 48VDC power source
switch and to all the 8 RJ-45
act as a normal RJ-45 port
and the PoE LED is OFF.
No power is being sent out
must be strong enough to
provide power to the 6K
8 Port@ 10/100Mb Copper ports
traffic is not affected by PoE.
from the port.
port.


The Magnum 6KP8-45-2MT eight port Module is a combo module with copper
equipped with six 10/100 RJ-45 ports and two 100Mb MTRJ fiber ports. When installed
advantage of placing more ports on one module. The 6KP8-45-2SLC is equipped with 6
The Magnum GBIC-SXSC is a multi-mode Gigabit fiber connector
supports cable distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e.,
and fiber (Small Form Factor) MTRJ type ports. The small sizes of MTRJ connectors
When installed in a Magnum 6K16-Series Switch, it supports the standard distances as
is coming to the PoE ports for some reason, all the PoE port LEDs are ON
give an advantage of placing more fiber ports on one module. The 6KP8-45-2MT is
equipped with SC type connectors and can be easily snapped in and out. The Gigabit
fiber ports are most popular as server-to-switch and switch-to-switch applications. It
simultaneously to indicate a trouble condition. The ports will still operate
Single-Mode Fiber port (LC)
1@ 1000Mb Fiber SC + 4@10/ 100Mb
10/100 L
1 3 5 7
mentioned on 5.2.4. and the LEDs also act similarly.
10/100 RJ-45 ports and 2 Single-mode fiber ports.
The small size of LC connectors give an
mentioned on 5.2.3. and the LEDs also
eight port Module is a combo module
in a Magnum 6K16-Series Switch, it
properly for data traffic.
with copper and fiber (Small Form
supports the standard distances as
F/
Factor) LC type fiber ports.
550m at full duplex.
act similarly.
The Magnum 6KP8-45SLC

removing the transceiver, press the clips on either side of the transceiver at the same time
with SC type connectors and can be easily snapped in and out. The Gigabit fiber ports are
The two Giga port has been offered as GBPM-2OTX (fiber or RJ-45), whereas the single
The GBIC transceiver has been offered in the modular slot with multiple options as per
the user requirement. The two Giga port has been offered as GBPM-2OTX (fiber or RJ-
Each port has an Activity (ACT) LED indicating packets being received and a
The Magnum GBIC-LXSC is a single-mode Gigabit fiber connector equipped
1@ 1000Mb Fiber SC + 2@ 100Mb SC
45), whereas the single Gigabit module comes in two different flavor of G+2 (100Mb
The GBIC transceiver is fastened using snap-in clips. Insert the transceiver
(take care to insert it the right way up, arrows on top) until it clicks in space. While
Link (LK) LED indicating proper connectivity with the remote device when lit.
F/
TX RX L
fiber ports) or G+4(10/100 RJ-45 ports) as shown in the above figure.
ACT
ACT
F/
F/
switch applications. It supports cable distances up
limits, i.e., 10,25, 40 or 70Km at full duplex, and
to the IEEE 802.3z standard 1000Mbps distance
most popular as server-to-switch and switch-to-
depend upon the Gigabit modules used.
(100Mb fiber ports) as shown below in
indicating packets being received and a
Each port has an Activity (ACT) LED
connectivity with the remote device
Gigabit module comes in flavors of
G+4(10/100 RJ-45 ports) or G+2
link (LK) LED indicating proper
and pull the transceiver out.
the above figure.

The Magnum 6K16-Series offered a wide selection of Gigabit speed with multiple choice
provides a wide variety of choices for various Gigabit transceivers covering a long range
of distance. The GBPM-2OTX also meets the requirement for those applications where a
standard GBICs to provide Gigabit (Gb) transceivers media flexibility . GBIC models are
suggestions listed below prior to contacting your supplier. However, if you are unsure of
available for both multi-mode (550m) and single-mode (10, 25, 40, 70)km fiber options,
intended to help locate, identify and correct these types of problems. Please follow the
The 6K16-Series Modules provide a GBIC opening for insertion of industry-
Each port has an Full and Half Duplex(F/H) Activity, (ACT) LED indicating
of copper or Fiber or mix for the modular slot via GBPM-2OTX (2 x Giga module).
While up to two Gigabit modules (maxm.) can be configured in the modular slot for
managed Gigabit media converter is required. The two Gigabit slot can be filled with
packets being received and a Link (LK) LED indicating proper connectivity with the
Magnum 6K16-Series Switch is a straightforward procedure (see INSTALLATION,
the procedures described in this section or if the Magnum 6K16-Series Switch is not
consistently high performance in all network environments. The installation of a
Should problems develop during installation or operation, this section is
All Magnum Ethernet products are designed to provide reliability and
Section 2.6); the operation is also straightforward and is discussed in Section 4.
GBPM-2OTX. The Dual Gigabit port option for the modular slot
and Gigabit copper as well, with new models appearing often.
underneath the front panel hold the 6K8-BLNK in place.
5.2.14 GBPM-2OTX (Two Gigabit option)
copper/Fiber or mix as per the application.
PM slot to maintain proper cooling air
The 6K8-BLNK is a blank
face plate or cover plate that must be
installed in any empty 6K16-Series
flow, safety, etc. Two screws
remote device when lit
when lit.

Series Switch product, it is recommended that the problem device be replaced
with a known good device. Verify whether or not the problem is corrected. If
not, go to Step 5 below. If the problem is corrected, the Magnum 6K16-Series
d. Any particular application that, when used, appears to create the problem;
performing as expected, do not attempt to repair the unit; instead contact your supplier
the Installation Section of the applicable chapter of this manual. Also check
of the Magnum 6K16-Series Switch unit or if unknown, contact GarrettCom,
to make sure that the various components of the network are interoperable.
number(s). Include the date(s) that you purchased the products from your
Series Switch unit. Be certain that each AC power cord is plugged into a
impaired during installation. (About 90% of network downtime can be
functioning electrical outlet. Use the PWR LEDs to verify each unit is
connected and the cables/wires have not been crimped or in some way
Inc.by fax, phone or email (support@garrettcom.com) for assistance.
Switch and its associated cables are functioning properly.
Please be prepared to provide the following information.
for assistance or contact GarrettCom Customer Support.
attributed to wiring and connector problems.)
c. The components involved in the problem;
a. The nature and duration of the problem;
b. Situations when the problem occurs;
6.2 When Calling for Assistance
receiving power.
supplier.

sheet or bag for shipping protection. ( You may retain all connectors and this
All returns for repair must be accompanied by a Return Material Authorization
material. This material may cause electro-static shock damage to the unit.
including personal computers, workstations, terminals and printers; plus, the
https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.
GarrettCom will carefully test and evaluate all returned products, will repair products
to the occurrence of the problem. Any changes to system administration
that are under warranty at no charge, and will return the warranty-repaired units to
the sender with shipping charges prepaid (see Warranty Information, Appendix A,
units under warranty. Testing and repair of product that is not under warranty will
Should you need to ship the unit back to GarrettCom, please follow these
GarrettCom reserves the right to charge for the testing of non-defective
for complete details). However, if the problem or condition causing the return
Failure symptoms, including a full description of the problem.
6.3 Return Material Authorization (RMA) Procedure
(RMA) number. To obtain an RMA number, please use this URL -
cannot be duplicated by GarrettCom, the unit will be returned as:
Name and phone number of your contact person.
Please have the following information readily available:
Packing List Number (or Sales Order Number)
procedures should all be noted in this record.
various network media types being used.
No Problem Found.
Name of your company / institution
Serial Number (or Invoice Number)
result in a customer (user) charge.
Installation Guide.)
instructions:
Your shipping address · Date of installation · Product name

Each Magnum Model 6K16-Series Managed Switch (DC option) requires a DC
125VDC or 5VDC environments. The 24VDC, -48VDC or 125VDC or 5VDC power input provides an Ethernet networking product utilizing a special type of power supply
GarrettCom, Inc. warrants its products to be free from defects in materials
Magnum 6K16-Series models, for –48V and 24V DC & 125VDC and 5V Power
power source, for 24VDC, -48VDC and 125VDC option or 5VDC input. The wide
replace components in the products that prove to be defective at no charge other
product has been damaged by misuse, misapplication, or as a result of service or
This warranty will not be effective if, in the opinion of GarrettCom, the
Please complete the warranty card as this acts as a product registration,
range of power input qualifies this product for use in 24VDC, -48VDC as well as
and workmanship for a period of three (3) years from the date of shipment by
than shipping and handling, provided that the product is returned pre-paid to
inspecting any product returned for warranty repair which turns out not to be
During this warranty period, GarrettCom will repair or, at its option,
GarrettCom reserves the right to make a charge for handling and
with a proven high-reliability record to fulfill the DC requirement.
and mail it to GarrettCom within two weeks of your purchase.
APPENDIX A: WARRANTY INFORMATION
DC Power Terminals : “+”, “ - ” , internally floating
47823 Westinghouse Dr.
modification other than by GarrettCom.
GarrettCom, Inc.
GarrettCom.
GarrettCom.
faulty.
Fremont, CA 94539-7437 · input

applied to the two inputs. It protects the Switch from incorrect DC input connections. An
The manual power “On-Off” Switch (optional) is used for powering the unit on
The –48VDC solution is particularly useful in the telecommunication industry,
other communication companies. In addition, many high availability equipment services,
facilities often use a battery backup system to maintain operations in the event of a power
Magnum 6K16-Series Switches are easily installed in a variety of applications
where it is common for facilities to operate on -48VDC power. Such companies include
where it is common for facilities to operate on 24VDC or 125VDC power. The 125VDC
where -48VDC, 24, or 125VDC or 5VDC power is used as the primary power source.
regular and wireless telephone service providers, Internet Service Providers (ISPs) and
The 24V and 125VDC options are particularly useful in the Industrial environment,
B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION
into the hub. This allows the Switch to operate only whenever DC power is correctly
incorrect polarity connection, for example, will neither affect the Switch, its internal
SUPPLY
FUSE +
The DC power configuration capability provides an Ethernet networking solution
such as broadcasters, publishers, newspaper operations, brokerage firms and other
failure. It is also frequently used for computer system backup, management and
utilizing a special power supply in switches with a proven track record.
power supply, nor will it blow the fuse in the internal power supply.
(24V, -48V, 125V)DC 30 watts typical for all (RJ-45 Ports)
17 watts typical for all (RJ-45 Ports)
and off when it is placed into or taken out of service.
A-
input line behind the two external power
connection terminals, so that the power
using diodes inside on each DC power
from an external source can only flow
The -48VDC, 24VDC and
125VDC power options are designed
operations monitoring equipment.

generating plants, etc. The 24VDC applications are mainly in the Industrial environment,
located on the left front of the unit and is equipped with three (3) screw-down lead posts.
The connection procedure is straightforward. Simply insert the DC leads to the
125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage
such as factory floor, HVAC equipment, military equipment, etc. The 5VDC options are
24VDC/125VDC/5VDC leads) to the DC power terminal block on the Magnum 6K16- Series Switch. The DC terminal block on the Magnum 6K16-Series Managed Switch is
The power terminals are identified as positive (+) and negative (-), and they are floating
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead
An ON-OFF manual switch is optional for DC power. This can be used to cut
(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely
Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or
inside the unit so that either may be grounded by the user if desired. The chassis is
Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground
will connect to the post labeled “+ve” and the rest to the “-ve”. The GND can be
so the user may elect to Ground either + or = terminal to suit the customer’s use.
options are mainly used in power utilities, such as electrical substations, electrical
This section describes the proper connection of the -48VDC leads (or
off power connections and as a RESET for the Magnum 6K16-Series Switch.
lead from 48V or –48V supply must be connected to the post labeled “+”.
When power is applied, the green PWR LED will illuminate.
mainly used for military or Industrial factory floor applications.
B4.1 UL Requirements for DC-powered units
within 6 inches of the terminal block.
“earth” or ground (GND).
hooked up at the last.
tightened.

supply, all specifications and configuration options for the Magnum 6K16-Series -48VDC,
To order the optional -48VDC power supply factory installed, add a suffix of “-
24VDC and 125VDC models with this Dual-Source option are identical to those listed in the Magnum 6K16-Series Fiber Switches Installation and User Guide, including
Similarly to order the optional 24VDC or 125VDC industrial specific power
supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s
With the exception of the dual DC input power connections and the power
Operation of Magnum 6K16-Series Switches with the optional -48VDC,
24VDC and 125VDC power supply is identical to that of the standard AC-powered
-48VDC” after the product’s standard model # Example: Magnum 6K16-SeriesR-
Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-125V)
Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)
Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)
Please refer to Section 6.0 for troubleshooting
Appendix B “Internal DC Power Supply Option”
B7.0 TROUBLESHOOTING
B5.0 OPERATION
125VDC.
models.
48VDC.

C2.0 MAGNUM 6K16-SERIES, with -48VDC, 24VDC and 125VDC Dual-Source
power supply) because of the blocking action of the diodes. This
125VDC Dual-Source power supply are designed for installations where a battery plant is the power source, and where two separate power sources are utilized in order to
125VDC Dual-Source Option units is identical to the standard AC-powered models. Refer to the main sections of this Installation and User Guide for a detailed description
a) The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw
125VDC dual source leads to the -48VDC, 24VDC & 125VDC power terminal block on the Magnum 6Ks Switch (shown in Figure )
The functionality of the Magnum 6K16-Series Switch -48VDC, 24VDC and
GND CHASSIS
e) The Switch will not receive power (and will not work) when both inputs are simultaneously
HUB
GND
supply internally (nor will it blow the fuse in the internal
The 6K16-Series-Switch models with the internal -48VDC, 24VDC and
can only flow into the unit. This allows the unit to operate whenever DC power is

is true even if one input connection is reversed while the
This section describes the proper connection of the -48VDC, 24VDC and
C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION
increase operational uptime and to simplify maintenance.
correctly applied to either or both of the two inputs
A-
B-
connected with reverse polarity or shorted
Switch is operating from the other source.
b) The Switch unit will not allow power to
power sources are not mixed together by
c) When one correct DC input is present,
the Switch will receive power if the other
should accidentally occur on either input,
absent or are both incorrectly connected.
of the Magnum 6K16-Series Switches.
The Dual-Source DC power
option is designed using diodes inside
of the chassis on each DC power input
external power connection terminals)
so that power from an external source
its power from the DC source with the
d) Reverse polarity connections, if they
line. A diode is placed in each of the
flow from a higher voltage input to a
will not damage the Switch or power
lower voltage input, i.e. the two DC
DC input is absent, or even if it is
four input lines (behind the four
highest voltage at a given time.
or grounded.
the hub.
DC terminal · block · option

Terminal Block on a Magnum -48VDC with Dual-Source option
The 24VDC & 125VDC terminal block on Magnum 6K16-Series’s is similar to
Dual-Src-48V for the regular DS model with no ON-OFF switch
Or Dual-Src125V-Switch for models with the ON-OFF switch
The -48VDC terminal block on the Magnum 6K16-Series Switch, as shown in Fig C5.0
determine the lead which is more “+ve potential”. The more “+ve” voltage lead from
The connection procedure is straightforward. Simply connect the DC leads to
Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC,
always use a digital voltmeter to measure the output voltage of the power supply and
the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground
(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely
Similarly, order the “Dual –source 24VDC” or “Dual-source 125VDC” as a
Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC
(A-), and the secondary power terminals as negative (B-), positive(B+). The chassis
“earth” or ground (GND) is a threaded post with a #6 nut. The Dual Source terminal
The following must be adhered to in order to conform to UL requirements:
To order the optional Dual-Source -48VDC power supply factory installed,
order “Dual-Src48V” as a separate line item following the product model.
so the user may elect to Ground either + or = terminal to suit the customer’s use.
or Dual-Src48V-SWITCH with the ON-OFF manual switch.
125VDC Dual-Src24V for regular models with no ON-OFF switch
posts. The primary terminals are identified as positive (A+), negative
Switch models are identical to that of the standard models.
48V or –48V supply must be connected to the post labeled “+”.
is located on the left front of the unit and is equipped with
separate line item following the product model.
that described in the –48VDC information above.
block for the 24VDC and 125VDC are similar.
within 6 inches of the terminal block.
five (5) screw-down lead
C5.1 UL Requirements
tightened.