UHC-P Guide to installation and use 2 & 4 housing models and narrow with PDA Palm* Covers software version 2.10






* A user manual for a Windows PDA is
found on the site
Frymaster www.frymaster.com
Frymaster, a member of the Commercial Food Equipment Service Association, recommends the use of CFESA certified technicians.
24 h/24 au 1-800-551-8633

NOTICE IF, DURING THE WARRANTY PERIOD, A CUSTOMER USES AN ITEM FOR THIS ENODIS EQUIPMENT OTHER THAN NEW OR RECYCLED UNMODIFIED PARTS PURCHASED DIRECTLY FROM FRYMASTER/DEAN OR ITS APPROVED SAV CENTRES AND/OR THE PART USED IS CHANGED AND NO LONGER CORRESPONDS TO HIS ORIGINAL CONFIGURATION, THAT GUARANTEE WILL BE CANCELLED. FURTHERMORE, FRYMASTER/DEAN AND ITS SUBSIDIARIES CANNOT BE HELD LIABLE FOR ALL CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER RESULTING DIRECTLY OR INDIRECTLY IN WHOLE OR PART FROM THE INSTALLATION OF ANY MODIFIED PARTS AND/OR ROOMS RECEIVED FROM AN UNAPPROVED SAV CENTRE.
THE APPARATUS SHALL BE PLACED ON A HORIZONTAL SURFACE.
L-UHC CANNOT BE INSTALLED IN A PLACE WHERE IT MAY BE EXPOSED TO WATER PROJECTIONS. THIS DEVICE SHALL NOT BE CLEANED BY SPRAYING
OR WATER PROJECTION.
FOR YOUR SAFETY DO NOT STORE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPOURS AT
PROXIMITY TO THIS OR OTHER APPARATUS.
WITHOUT HAVING PREVIOUSLY READ THIS MANUAL.
DO NOT USE L , WITHOUT HAVING PROPERLY INSTALLED AND CHECKED.
DO NOT USE L-UHC IF ALL ACCESS AND MAINTENANCE PANELS ARE
NOT IN PLACE AND PROPERLY FIXED.
THE FOLLOWING ARE THE MAIN REASONS FOR THIS:
USE PRECAUTIONS WHEN INSTALLING, USING OR CLEANING L Ο ΟΟ Η ΟΙ ΟΗ Η TO AVOID CONTACT WITH HOT SURFACES.


1.3 Installation of the grill clamp The grill clamp is shipped in the accessory package and designed to hold 1/3 tray for roasted products. It attaches to the grill to facilitate and make safer transfer of the grill into UHC.


The grill clamp fastens to the grill and keeps the roasted product in a tray of UHC-P, facilitating transfer up to the warm holding cabinet.
feet. The cabinet must be handled by at least two persons.
A. Carefully place the universal warm-up cabinet on its right side (direction)
when facing the front of the device), by exposing the base of the cabinet.
B. Mount the footholds on the base using long screw 410 mm-20 x 12 mm and washers
d) Discontinuation provided.
C. Screw your feet on the hold when you're up and tight.
D. Carefully return the HCU to vertical until it stands on these feet. Perform step
2, Powered.
CONTACT AREA OF THE BASE OF L'UHC-P AND WORK PLAN IS CORRECTLY FIXED BY A FOOD QUALITY SEALANT.

IN ACCORDANCE WITH LOCAL CODES OR, IF NO SUCH CODE EXISTS, THE CODE
NATIONAL ELECTRIC, ANSI/NFPA NO. 70-1990. A. Feeding requirements:
THIS DEVICE IS EQUIPPED WITH A THREE-PIN PLUG (EARTH) THAT PROTECTS AGAINST ELECTRICAL SHOCKS AND MUST BE CONNECTED DIRECTLY TO THE
A GROUNDING. DO NOT CUT AND REMOVE THE BETTING PIN AT
LAND OF THIS SHEET. B. Plug the universal hot-P cabinet into the electrical outlet. C. Place the power switch on position Walk. All control displays sss on in
green about 2 seconds after activation of the power switch. D. Monitor the temperature of housing. The heating time of the rooms at room temperature
at the 155°F (68°C) point of set-up is approximately 15 minutes. To reach a set point of 200°F (93°C), take about 25 minutes. If the set point is not systematically reached within these deadlines, call your VAS center to have the device repaired.

3 Overview of the instructions for use The Universal Warm-P Cabinet (UHC-P) has four units that contain up to three product trays or two housing units, each containing three shelves. Each housing has a controller, which indicates the product and duration of hot holding for each tray position. Figure 1.


L-UHC-P is immediately ready to work, with the accommodation set for breakfast and lunch menus illustrated in the chart below. Figure 2.
Breakfast configuration Default settings
Setting up a lunch Default settings
Left Centre Right Left Centre right
ROUN ROUN CBAC
GRCK 4-1 4-1
SCRA FOLD CBAC
NUGG NONE NUGG
SCRA BISC NONE
Figure 2: Default settings of the UHC-P.
1. Turn the unit on. 2. The displays turn on and indicate LOW TEMP. 3. Press the Menu button to scroll through the screen up to the desired menu, release the key and immediately press the Temperature key. The chosen menu is locked. NOTES: All temperature and hold time settings are in accordance with McDonald's specifications. Menu changes or other settings require an electronic Palm Pilot calendar and associated software. The programming of the cabinet with the Palm is discussed in Chapter 4. 3.2 Timer Instructions Press the timer button adjacent to the desired housing. The timer performs a countdown from a predefined value. The display alternates between the product name and remaining hold time. If more than one housing contains the same product, the location corresponding to the remaining shortest holding time is indicated by a brighter display and light points. Timer Stop Press the Timer button next to the housing to turn off the corresponding timer. The timer stops and the display darkens, indicating inactivity. The "Use first" indicator moves to the next appropriate housing.

3.3. Buffer timer The buffer timer allows to reduce the holding times by 5 minutes increments. It allows to take into account the time spent by the product in another UHC. To use this function, press the Timer key once the product is placed in a cabinet housing, which results in starting the preset timer. Press the Timer key within three seconds to reduce hold time by 5 minutes. Press the Timer key again to further reduce hold time. 3.4. Cooking extension invitations The invitation to extend the cooking time shall sound within a predefined period before expiry of the last tray for any specific product. No acknowledgement of receipt is required. The 3 seconds audible alarm and the COOK More message display serve as an extension of product cooking reminder. 3.5 Use of Cleaning Mode Press the Menu button several times until Clean Mode appears. Release the key and immediately press the Temperature button. Upload Palm will pop up. (This is an invitation to download data captured by the cabinet during day operations. The instructions for downloading data to the Palm appear in Chapter 8) Press the Temperature key to display Slot Cln Mode. The set point thus increases to 125°F (52°C) for all dwellings. The display alternates between SLOT CLN Mode and Not Safe Yet, until the housing temperature reaches 125°F (52°C). The display then goes to Safe to Cln. Leave the Clean mode by pressing the Menu button until the desired menu appears. Release the key and immediately press the Temperature button; the choice is locked. This operation must be carried out for each dwelling. L-display indicates Slot Temp Low until the set point is reached for the selected product. 3.6 Deactivation of housing Press the Menu button of a dwelling until Slot Off displays. Release the key and immediately press the Temperature button; your choice is locked. 3.7. Temperature display Press the Temperature key four times to display temperatures and set points in the following order:


A Palm Pilot on which the software of UHC-P is loaded is available. All programming of the cabinet, except for initial default settings, entered on the Palm Pilot and then transferred to UHC-P. Below you will find a typical UHC-P screen on a Palm Pilot explained by legends. The appearance of the menu bar varies according to software version*. Programming and use are dealt with in Chapters 4 to 7. Palm software must be loaded onto a computer accessible to the store manager in order for it to acquire and load UHC-P. The software loading and acquisition are described in Chapter 9. For a description of his instructions for use, please refer to the Palm Pilot manual.
To access it, select Setup at the top
Menus Access to the configurations of a wardrobe for breakfast, lunch and specialities.
Editing Access to Palm software functions.
Info Access to the software version of UHC-P.
View Access to the functions of UHC-P software.
left of the screen.
Food library Contains the hot-keeping parameters for existing items and user-created daily specialties. Articles are stored here and copied into a menu if necessary. They are stored in the library at all times unless erased by user.
Menu Products are transferred here from the food library. The Menu selection also reveals a chart that allows the cabinet configuration. A password is required. Refer to Chapter 5.

Modify This function, which requires a password, allows the modification of an article's maintenance settings. For passwords, see Chapter 5.
and Specialties of the Day Items are stored in a special menu: breakfast, lunch or specialty of the day. The menu for an article is selected here.
Add Creates new items. A password is required. Refer to Chapter 5.
Remove Allows to remove items from a menu.
Language Allows you to change the displayed language and modify the temperature unit (Fahrenheit/Celsius). A password is required. Refer to Chapter 5.
Newspapers Displays the activity of the cabinet.
abc Provides access to a keyboard, for text input and modification of menu items.
123 Provides access to a digital keyboard for the digital inputs.
Menu bar* · Breakfast, lunch


Lunch Indicates the menu for which the cabinet is configured. The breakfast menu and specialities of the day are displayed in a similar way.
Cabinet S The items corresponding to the housing positions are selected by selecting the triangle in each accommodation window.
i Selectable icon to access stored cabinet configurations.
Receive Allows you to download the configurations and logs of daily activity in the cabinet.
Transfer Allows the transmission or transfer of cabinet configurations from Palm Pilot to UHC-P by infrared link.
abc Provides access to a keyboard, for text input and modification of menu items.
123 Provides access to a digital keyboard for the digital inputs.
Viewing

A PDA with installed UHC-P software must be used to modify or add menu items stored in the UHC -P cabinet. A Palm Pilot with the loaded software is available for UHC-P. Other Palm models can be used, but they must have version 4.0 or later of the Palm operating system. Windows PDAs can also be used to program the cabinet. In this case, a different software is required, processed in a separate manual. A Palm Pilot is not required to start using the UHC-P. A default menu is loaded at the factory. However, it should be noted that the Palm and its UHC-P software facilitate creation and resumption of promotional item configurations and special configurations. The cabinet configurations and daily activity of the wardrobe can be downloaded from UHC-P to Palm. With proper authorizations, menu items can be created and modified in the software. Figure 1. New items, as well as existing products, are stored in the Food Library where they can be transferred to the Menu and downloaded to UHC-P cabinet. The configurations defined in the Palm Pilot are transferred via infrared port of UHC-P cabinet. See Figure 2. 4.1 Opening the Palm Software Turn the Palm Pilot on and select the software menu option by typing it ("All", probably), in the upper right corner of the screen. A drop-down menu offers software function groups and other functions. Highlight Utilities by selecting this option. See Figure 3. The UHC-P icon appears on the screen. Select it. Setup screen displays. See Figure 4.


Figure 1: Palm Pilot with UHC-P software displayed.


Figure 3: Select the UHC-P software from the Palm Utilities menu.
Figure 4: UHC-P software allows the transfer of items from the Food Library to the current menu.
Port of reception · Receiving Lens

4.2 UHC-P Software Configuration for Use of 2 or 4 Housing 4.3 Transfer Products from Food Library to Menu










To remove an item from a menu, highlight it in the menu window and select the Remove button at the bottom of the menu display.



Use this procedure to configure the cabinet for lunch and every Special menu.

5 Adding menu items 5.1 Enter password The addition or modification of articles in the food library requires a password. Select the key icon at the top in the center of UHC-P software screen. Follow the arrow at the top of Figure 1. Security Manager screen displays. Select icon abc bottom left of the screen. Follow the arrow at the bottom of Figure 1. Use the virtual keyboard that displays to enter the required password (manager), then select Done. The Security Manager screen displays with the password in place. Select OK. Current Security screen displays. Select OK. Once the correct password is entered, menu items can be entered and changed. 5.2 Entry of a new product

Figure 1 The entry of a password allows the addition of new products and modification of existing ones.








Step 7*: Use the vertical cursor to the right of the screen to access four additional options and adjust them according to the new product.
*NOTE: Temperatures and retention times, as well as other parameters associated with adding products to a menu will be distributed by McDonald's officials.
Select OK. The new item is stored in the food library and can be moved to a menu for transfer to UHC-P.



Step 2: The Settings Menu screen displays. Highlight a menu to remove by selecting it. Select the Delete button to remove the highlighted menu. Use the New button to create a menu. Select the Abbr: field, then icon abc to access the keyboard and enter a name for the new menu. Repeat to enter the name and description of the menu. Select the Save button to save the new menu. NOTES: The new menu should be provided by moving items from the food library to the new menu, a procedure described in section 4.3.

6 Preset The Preset Manager allows the loading and permanent storage of cabinet configurations in the Palm Pilot. These configurations, which reflect the daily menu settings, weekends and specials for all five menus stored in UHC-P cabinets, can be recalled and transferred to several UHC/P cabinet. This function has been improved with version 2.10 of the software. Its operation, called Saving Cabinets, is dealt with in Section 6.3. This function is useful for storing and accessing cabinet configurations from different stores or specialties of the day. The configuration of the cabinet displayed on the Palm must be changed when defining special preset settings. To name and record the existing cabinet configurations in your Palm as preset, go to step 3 below. The cabinet configurations can also be downloaded from the UHC-P to Palm. This procedure is dealt with in Chapter 8. Follow the steps below to access Preset Manager and create, then store configurations. 6.1 Preset configuration (used with pre-version 2.10) software versions








6.2 Loading presets (with software versions prior to version 2.10) 6.3 Recording a cabinet configuration with the software version 2.10






Open (Ovurir): Loads the highlighted cabinet configuration. Delete: Clears the highlighted cabinet configurations. Save (Save): Saves new cabinet configurations in the Saved Cabinets area. Select this button only after naming the cabinet configuration. New (New): Start the process of recording configuration from cabinet. Cancel (Cancel): Closes the program or cancels the configuration recording operation from cabinet.













7 Selecting the temperature unit and language You must enter a password to change the temperature and language. See Password Access in Chapter 5. Access to the temperature display and language choice sss from the Language button of Setup screen. See Figure 1. The change in language or temperature takes effect immediately after selection. 7.1. Change in temperature unit

Figure 1: The arrow points to the Language button, where you can change the temperature unit and language.



Take the procedure again, deselecting the Celsius box, to go back to Fahrenheit degrees.




Take the procedure to use another language.

The cabinet records daily activity and these data must be downloaded to the Palm every day before switching off the cupboard. This operation may take place at any time. The cabinet also offers a prompt for downloading data when the Cleanup mode is enabled. See page 3-2. A cabinet configuration can also be downloaded to the Palm. Proceed as indicated on the left and select the Menu button. The cabinet displayed on the PDA must be saved before receiving a new configuration, which will overwrite the existing Palm display. For instructions on how to use Save Cabinets, see Chapter 6. The configurations received from close-up or two housing units will change this parameter on the Palm. For the software configuration instructions, see section 4.2.

Figure 1: To prepare the Palm Pilot for receiving data from UHC-P cabinet, select the Receive button.

Figure 2: To download a cabinet configuration, hold the Palm parallel to the floor and not more than 30 cm from the reception port, at the top right of the wardrobe. Select the RX Mnems button. To download a daily activity log, select the Rx Logs button. A dialog box will appear once the transfer is completed.

9 Acquisition and loading of software for the Palm A Palm Pilot on which the software of UHC-P is loaded is available as an accessory from Frymaster. (Ref. No. 106-4229.UHC-P software, which can be loaded on a Palm or Sony electronic calendar, is available on the Frymaster website, Frymaster.com. Palm version 4.0 or later operating system is essential to use the software. For instructions on installing, using and deleting Palm software see the electronic calendar manual. Any outdated or inoperative UHC-P software should be removed from the Palm Pilot before installing a new UHC/P software. The operating system version control instructions are provided below for a Palm electronic calendar. This information is also available in the Palm or Sony electronic calendar manual. 9.1. Palm operating system version number control




System icon









9.3 Loading software on Palm e-Agenda These instructions assume that the Palm software is installed on your computer and a Palm with minimum version 4.0 operating system is connected to the computer. For instructions on installing, using and deleting Palm software see the electronic calendar manual. Any outdated or inoperative UHC-P software should be removed from the Palm Pilot before installing a new UHC/P software.
















The configuration of the software for use of 2 or 4 housing units is dealt with in Chapter 4.

9.4 Transfer of Palm software from one electronic calendar to another The UHC-P software can be downloaded via infrared link or transferred from one Palm to another by placing the two devices in "head to head" before selecting Beam on a drop down menu. Follow the following steps to transfer software from one device to another.






Select the Language button and change your default language, which will be used in the food library.
The configuration of the software for use of 2 or 4 housing units is dealt with in Chapter 4.


Duration
temperature
(min)
Plate above 175 °F (79 °C) Sausage SAUS BFST Plate below 175 °C (79°C) 60
Plate above 175 °F (79 °C) Round eggs ROUN BFST Plate below 175 °C (79°C) 20
Plate above 175 °F (79 °C) Folded eggs FOLD BFST Plate below 175 °C (79°C) 20
Plate above 175 °F (79 °C) Drifted eggs SCRA BFST Plate below 175 °C (79°C) 20
Plate above 175 °F (79 °C) Canadian Bacon CBAC BFST Plate below 175 °C (79°C) 30
Plate above 175 °F (79 °C) English MUFF BFST Muffins Plate below 175 °C (79°C) 20
Plate above 175 °F (79 °C) Biscuits BISC BFST Plate below 175 °C (79°C) 30
Plate above 175 °F (79 °C) Burritos BURR BFST Plate below 175 °C (79°C) 20
Plate above 185 °F (85 °C) Standard pallets 10-1 LNCH Plate below 185 °C (85°C) 15
Plate above 185°F (85°C) 1⁄4 pound and Big Xtra! 4-1 LNCH Plate less than 185 °F (85 °C) 15
Plate above 185 °F (85 °C) Grilled chicken NUGG LNCH Plate below 185 °C (85°C) 60
Plate above 200 °F (93 °C) Fish FISH LNCH Plate below 200 °C (93°C) 30
Plate above 200 °F (93 °C) McChicken McCK LNCH Plate below 200 °C (93°C) 30

Appendix B: Cleaning and Preventive Maintenance After each use – Cleaning of trays and grids 1. Remove all plastic trays and grilles. Put them in the sink to clean them.
Every day – Cleaning the wardrobe 1. At the end of the day, activate Cleanup mode. Follow the procedure on page 3-2.
Note: Do not use any other cleaners than MCD (APSC)(HCS). The use of other products may damage the control components. 3. With the cabinet cleaning brush, push all separated particles to remove them from the opposite side of the wardrobe. 4. Use a clean, disinfected wet cloth and the cabinet cleaning brush to clean each unit. Clean the lower and upper surfaces of each dwelling. 5. On all the outer surfaces of the cabinet, pass a clean and disinfected cloth that has been soaked in the MCD ASPC (HCS). 6. Turn off the device.

Once a week – Wardrobe housing Calibrate the upper and lower plates of all four UHC units by performing the following procedure with clean, empty housings at operating temperature for a minimum of 30 minutes. 1. Press the Temperature key (see Figure 1, page 3-1) to ensure that the accommodation is at the point of disposal. 2. Slide the Atkins sensor into a housing by turning it upwards to measure the top or bottom heating plate, for measuring the lower heating plate. Bring the sensor to the center of the plate. To obtain accurate measurement, the sensor must be within ±25 mm (1 inch) from the centre of the plate. 3. Wait three minutes for the sensor to stabilize. 4. Read the temperature on the Atkins sensor and compare it to the cabinet reading, which displays by pressing once (upper plate temperature) or twice (lower plate temperature), at the Temperature key. The temperature displayed shall be ±3 °C (±5 °F) of the temperature indicated by the sensor. If the survey is outside these limits, proceed as follows. Launch the UHC-P software on the Palm and proceed as follows:



Figure 2: Tap View in the menu bar, then on Cabinet in the drop-down menu.


150°F 145°F -5
66°C 69°C 3



less two people.

a. If the cabinet is an independent device or if it's at the top of a battery configuration, use a 5/16 Remove the top of the cabinet. Go to step 10.
b. If the cabinet is an independent device or if it's at the top of a battery configuration, use a 5/16-to-removal socket key to remove all four screws that attach the shelf in place. The screws are located on either side of the apparatus, near the top corners of the inner panel.


Appendix D: N/A For UHC-P The procedure of the universal storage cabinet for hot-P used for FRIED PRODUCTS is similar to our current procedure. The only difference is that the fried product is placed on a grid in a pick-up tray and then inserted into the predesignated unit of the cabinet. No plate coating is required for these trays. The procedure of the universal storage cabinet for hot-P used for GRILLED PRODUCTS is similar to our current procedure, with the following exceptions:

Units Plates Plates No. of pieces Bags No of pieces
Ultra-high volume 30/1 24/6 18/3 6/1 18/3 30/3 20/1 9/1
Units Plates Platforms Plates Plateaux Plateaux Plateauaux Platels Plateaux
Period BISC SAUS FOLD SCRA ROUN CBAC MUFF BURR

Breakfast configuration Default settings
Setting up a lunch Default settings
Left Centre Right Left Centre right

Setting up a typical breakfast

Setting up a typical lunch Left wardrobe* Right cabinet
Left Centre Right Left Centre right

*Note: In this example, Biscuits (BISC) and Muffins (MUFF) occupy the three top positions of a dwelling; therefore, the central tray must be adapted to the product (BICS or MUFF) and left and right shelf positions should be adjusted on NOE. If a tray position does not contain any product, select NOE.

Recommended battery - Normal volume 9/3
Recommended battery - Ultra high volume 18/6









Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000