EN
Frymaster logo
Official user manual

Frymaster SR114E

12 pages·372 KB·Fryer·PDF·ENDEFRITNLJA
Frymaster SR114E
Table of Contents 54 sections Super Runner Series Electric Fryers Installation & Operation Manual · Super Runner Series Electric · SR114E · NON-CE & · … ShowHide
Page 1 of the Frymaster SR114E user manual — FEB 2007
Page 1 · click to enlarge
Page 1
Frymaster SR114E — Super Runner Series Electric Fryers Installation & Operation Manual diagram (page 1)
Fig. 1 · Super Runner Series Electric Fryers Installation & O…

Super Runner Series Electric Fryers Installation & Operation Manual

Super Runner Series Electric

SR114E

Frymaster SR114E — Super Runner Series Electric diagram (page 1)
Fig. 2 · Super Runner Series Electric

NON-CE &

Dean, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

24-Hour Service Hotline 1-800-551-8633 *8196010*

FEB 2007

Page 2 of the Frymaster SR114E user manual — Super Runner Series Electric Fryers Installation & Operation Manual
Page 2 · click to enlarge
Page 2

Please read all sections of this manual and retain for future reference.

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

Page 3 of the Frymaster SR114E user manual — Super Runner Series Electric Fryers Installation & Operation Manual
Page 3 · click to enlarge
Page 3
Page 4 of the Frymaster SR114E user manual — SUPER RUNNER SERIES ELECTRIC FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS
Page 4 · click to enlarge
Page 4

SUPER RUNNER SERIES ELECTRIC FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS

1.1 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual you will find notations enclosed in double-bordered boxes with the symbol . The information contained in the box concerns actions or conditions that may cause or result in injury to personnel or damage to your system, and/or cause your system to malfunction. 1.2 General Installation Instructions

supply having a contact separation of at least 3-mm in all poles must be incorporated in the fixed

wiring.

disconnection from the power supply (e.g., a circuit breaker) is provided.

wires having a temperature rating of not less than 194°F (90°C).

Authorized Service Center technician or a similarly qualified person in order to avoid a hazard.

on the rating plate located on the inside of the appliance door.

when installing or servicing this equipment.

installations, optional equipment casters must be used. Questions? Call 1-800-551-8633.

appliances or installing the fryer in an alcove, or by separate means, such as straps or chains.

cause injury. The appliance area must be free and clear of combustible material at all times.

Page 5 of the Frymaster SR114E user manual — 1.3 Power Requirements
Page 5 · click to enlarge
Page 5

SUPER RUNNER SERIES ELECTRIC FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS

CLEARANCE AND VENTILATION This fryer must be installed with a 6-inch (150-mm) clearance at both sides and back when installed adjacent to combustible construction. No clearance is required when installed adjacent to non-combustible construction. A minimum of 24-inches (600-mm) clearance should be provided at the front of the fryer. INSTALLATION For units equipped with legs: Lift the unit and move it into its final position. Do not drag or push the fryer into position. Doing so may damage the legs. Level the unit front to back and side to side. If the fryer is not level, the unit will not function efficiently. A. Adjust leg height with an adjustable or 1-1/16-inch (27-mm) open-end wrench by turning the hexagon-shaped foot

on the bottom of the leg. NOTE: The foot is for minor leg height adjustment only. Do not adjust outward more than ¾-inch (19-mm). B. When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the

foot to the required height. For units equipped with casters: Roll the unit into its final position and lock the front casters.

When the fryer is leveled in its final position, install the restraints provided with the unit to limit its movement so that it does not depend on or transmit stress to the electrical conduit or connection. Install the restraints in accordance with the provided instructions (see illustration below). If the restraints are disconnected for service or other reasons, they must be reconnected before the fryer is used.

Frymaster SR114E — SUPER RUNNER SERIES ELECTRIC FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS diagram (page 5)
Fig. 3

1.3 Power Requirements

Use copper wire ONLY suitable for at least 194°F (90°C) MODELVOLTAGEPHASEWIRE SERVICEMINIMUM WIRE SIZE AWG mmAMPS (per leg) 14 kW208Single34 (5.83)68 14 kW208338 (4.11)39 14 kW240Single34 (5.19)59 14 kW240338 (3.26)34 14 kW230/400346 (4.11)21

number plate located on the inside of the fryer door.

number plate located inside the fryer door.

furnished with the equipment. Wiring diagrams are located inside the fryer door.

Page 6 of the Frymaster SR114E user manual — 1.3 Power Requirements
Page 6 · click to enlarge
Page 6

2.1 Initial Startup Wash the unit and accessories thoroughly with hot, soapy water to remove any film residue, dust or debris. Rinse and wipe dry. Close the drain valve completely. Ensure the thermostat and high-limit thermostat sensing bulbs inside the frypot are securely seated in the holding clamp and that the clamp screws are secure (see photo at right).

Frymaster SR114E — 1.3 Power Requirements diagram (page 6)
Fig. 4 · 1.3 Power Requirements

elements.

WARNING NEVER set a complete block of solid shortening on top of heating elements. To do so will damage the elements and increase the potential for flash-point shortening temperatures and subsequent fire. 1. Fill the frypot with vegetable oil to the bottom OIL LEVEL line located on the rear of the frypot. This will allow for oil expansion as heat is applied. Do not fill cold oil any higher than the bottom line; overflow may occur as heat expands the oil. If solid shortening is used, carefully pack solid shortening into the bottom of the frypot, below, between and around the elements. Use extreme care not to damage the elements or sensing bulbs when packing the shortening into the frypot. Ensure the elements are completely covered with shortening prior to engaging power switch. Never insert a solid block of shortening into frypot on top of the elements. Hot spots and element damage will occur, and the potential for flash-fire increases. 2. Ensure that the power cord is plugged into the appropriate receptacle. Verify that the face of the plug is flush with the outlet plate, with no portion of the prongs visible. 3. Set the thermostat dial to the desired temperature. Turn the fryer power switch on and allow the oil to come to operating temperature. If the fryer temperature exceeds 435°F (218°C) [410°F (210°C)], the over-temperature protection circuit will trip. Allow the fryer to remain off for 30 minutes before resetting the high-limit switch. Contact a service agent if the problem persists.

Frymaster SR114E — 1.3 Power Requirements diagram (page 6)
Fig. 5 · 1.3 Power Requirements
4. Ensure that the oil/shortening level is at the top OIL LEVEL line when the fryer reaches operating temperature (the indicator light will cycle on and off). It may be necessary to add oil or shortening to bring the level up to the proper mark. If solid shortening is used, it may be necessary to turn the power switch off, and then back on, as the shortening melts, to prevent hot spots.
Show 6 more labels / short text on this page
Thermostat Probe · High-Limit · Setup · High-Limit · Reset Thermostat · Control
Page 7 of the Frymaster SR114E user manual — 1.3 Power Requirements
Page 7 · click to enlarge
Page 7

Shutdown 1. Press the ON/OFF switch to the "OFF" position. 2. Filter oil or shortening and clean the fryer. 3. Place the frypot covers on frypots. 2.2 Daily Operation 1. Do not allow grease to accumulate or harden on the frame or body of the fryer. Clean the fryer inside and out with a solution of detergent and hot water daily. 2. Filter the cooking oil by draining the frypot through a filter cone at least daily. After the oil has been drained from the frypot, remove any residue from the pot, using a scraper if necessary. Use care not to damage the elements or sensor bulbs when removing residue from the frypot. 3. Clean the frypot at least once each week by filling it to just below the upper oil level mark with water. Add one cup of detergent and bring the solution to a boil. Allow the solution to simmer for 10-15 minutes, then drain and rinse the frypot with clean water twice. Add ¼ cup of white vinegar to the last rinse to neutralize any alkalinity remaining from the detergent. Wipe the frypot surfaces with a dry towel before refilling with cooking oil. If the fryer is not to be used immediately after cleaning, it is suggested that the inside of the frypot be wiped down with a light coat of cooking oil to prevent rust. 2.3 Recommended Spare Parts

DESCRIPTIONPART # Temperature Probe807-1568 High-Limit Thermostat807-3559 High-Limit Thermostat CE807-3560 Transformer (208/222/230/240)807-1999 Relay (12VDC)807-1683 Element, 208V807-3978 Element, 240V807-3979 Element, 230V807-4340 Light, Heat IndicatorWhite807-1525 Leg, 6-inch810-2053 Caster, 5-inch w/o Brake810-0356 Caster, 5-inch w/Brake810-0357 Strap Restraint Kit (Leg-Equipped Units)826-1095 Chain Restraint Kit (Caster-Equipped Units)826-0900
Page 8 of the Frymaster SR114E user manual — 1.3 Power Requirements
Page 8 · click to enlarge
Page 8

2.4.1 Wiring Diagram Single Phase

Frymaster SR114E — 1.3 Power Requirements diagram (page 8)
Fig. 6 · 1.3 Power Requirements
Page 9 of the Frymaster SR114E user manual — 8051513A
Page 9 · click to enlarge
Page 9

2.4.2 Wiring Diagram 3-Phase

W10C BLK

ELEMENTS

LIGHT

HIGH LIMIT

W11C BLK

RELAY

COM

W27C BLK

W21C BLK W21C BLK

W22C BLK

W24C BLU

NO NC

W23C YEL

W27C BLK

W25C BLK

W26C BLK

W28C BLK

TRANSFORMER

W25C BLK

W23C YEL

W24C BLU

W22C BLK

WHT

W13C BRN

W15C RED

2 1 4 5

RED

BLK

L2 L3 L2 L1 L1 L3

7 12 10 11 9 8

W9C BLU

W22C BLK

W8C BLU

W21C BLK

W7C BLU

W23C YEL

W13C BRN

W24C BLU

W17C WHT W15C RED

W12C BLK

W13C BRN

W14C ORG

FRAME

W18C BLU

W16C BLK

W20C RED

RED

W19C WHT

WHT

GROUND

TEMP PROBE

ON/OFF

1 2 3 4 5 6 7 8 12 9 10 11

8051513A

15 13 14

Page 10 of the Frymaster SR114E user manual — 8051586A
Page 10 · click to enlarge
Page 10

2.4.3 Wiring Diagram 3-Phase WYE

ELEMENTS

LIGHT

HIGH LIMIT

RELAY

COM NO

NC

TRANSFORMER

2 1 4 5

L1 N N N L2 L3

PRIMARY (LINE)

SECONDARY (LOAD)

7 12 10 11 9 8

FRAME

TEMP PROBE

ON/OFF

1 2 3 4 5 6 7 8 12 9 10 11

8051586A

15 13 14

Page 11 of the Frymaster SR114E user manual — COM NO
Page 11 · click to enlarge
Page 11

THIS PAGE INTENTIONALLY LEFT BLANK.

Page 12 of the Frymaster SR114E user manual — 819-6010 FEB 2007
Page 12 · click to enlarge
Page 12
Frymaster SR114E — 819-6010 FEB 2007 diagram (page 12)
Fig. 7
Frymaster SR114E — 819-6010 FEB 2007 diagram (page 12)
Fig. 8

Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000

Shipping Address8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135

Price$8.00 PRINTED IN THE UNITED STATES

819-6010 FEB 2007

Ask about the Frymaster SR114E

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster SR114E

Be the first to ask — other owners or our team will answer.

Original document

Frymaster SR114E manual PDF

12 pages·372 KB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…