Table of Contents 46 sections Super Marathon Series Gas Fryers Installation & Operation Manual · NON-CE & · *8196001* · CHAPTER 1: INTRODUCTION · … ShowHide
Page 1 of the Frymaster SM50 user manual — *8196001*
Page 1 · click to enlarge
Page 1

Super Marathon Series Gas Fryers Installation & Operation Manual

Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 1)
Fig. 1 · Super Marathon Series Gas Fryers Installation & Oper…

Series SM20, SM40, SM50, SM60 & SM80

Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 1)
Fig. 2 · Super Marathon Series Gas Fryers Installation & Oper…

NON-CE &

Dean, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

PRINTED IN THE USA 24-Hour Service Hotline 1-800-551-8633 MAY 2006

E-mailservice@ frymaster.com

*8196001*

www.frymaster.com

Page 2 of the Frymaster SM50 user manual — Super Marathon Series Gas Fryers Installation & Operation Manual
Page 2 · click to enlarge
Page 2

Please read all sections of this manual and retain for future reference.

Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 2)
Fig. 3 · Super Marathon Series Gas Fryers Installation & Oper…
Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 2)
Fig. 4 · Super Marathon Series Gas Fryers Installation & Oper…
Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 2)
Fig. 5 · Super Marathon Series Gas Fryers Installation & Oper…

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 2)
Fig. 6 · Super Marathon Series Gas Fryers Installation & Oper…
Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 2)
Fig. 7 · Super Marathon Series Gas Fryers Installation & Oper…

DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all times when the fryer is in use.

Page 3 of the Frymaster SM50 user manual — Super Marathon Series Gas Fryers Installation & Operation Manual
Page 3 · click to enlarge
Page 3
Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 3)
Fig. 8 · Super Marathon Series Gas Fryers Installation & Oper…
Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 3)
Fig. 9 · Super Marathon Series Gas Fryers Installation & Oper…
Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 3)
Fig. 10 · Super Marathon Series Gas Fryers Installation & Oper…
Frymaster SM50 — Super Marathon Series Gas Fryers Installation & Operation Manual diagram (page 3)
Fig. 11 · Super Marathon Series Gas Fryers Installation & Oper…

Safe and satisfactory operation of Frymaster Dean equipment depends upon its proper installation. Installation MUST conform with local codes, or in the absence of local codes, to European Union (CE) Standards.

Page 4 of the Frymaster SM50 user manual — Super Marathon Series Gas Fryers Installation & Operation Manual
Page 4 · click to enlarge
Page 4
Page 4 of the Frymaster SM50 user manual — Super Marathon Series Gas Fryers Installation & Operation Manual
Page 5 of the Frymaster SM50 user manual — Super Marathon Series Gas Fryers Installation & Operation Manual
Page 5 · click to enlarge
Page 5
Page 5 of the Frymaster SM50 user manual — Super Marathon Series Gas Fryers Installation & Operation Manual
Page 6 of the Frymaster SM50 user manual — CHAPTER 1: INTRODUCTION
Page 6 · click to enlarge
Page 6

CHAPTER 1: INTRODUCTION

1.1 Applicability and Validity Dean Super Marathon Series gas model family has been approved by the European Union (EU) for sale and installation in all EU countries. This manual is applicable to and valid for all Dean Super Marathon Series gas units sold in English-speaking countries, including those in the European Union. Where conflicts exist between instructions and information in this manual and local or national codes of the country in which the equipment is installed, installation and operation shall comply with those codes. This appliance is for professional use only. Operating information for Dean equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.5. All installation and service on Dean equipment must be preformed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.5. 1.2 Ordering Parts Customers may order parts directly from their local Authorized Parts Distributor. For this address and phone number, contact your maintenance and repair center or call the factory. The factory address and phone numbers are on the back cover of this manual. To speed up your order, the following information is required:

Model Number Type Serial Number Optional Equipment Item Part Number Quantity Needed 1.3 Service Information Call the 1-800-551-8633 or (318) 865-1711 Service Hotline number for the location of your nearest maintenance and repair center. Always give the model and serial numbers of your fryer.

To assist you more efficiently, the following information will be needed:

Model Number Type Serial Number Optional Equipment Nature of Problem Additional information (i.e. cooking environment, time of day, and other pertinent information) may be helpful in solving your service problem.

Page 7 of the Frymaster SM50 user manual — 1.5 Definitions Qualified and/or Authorized Operating Personnel
Page 7 · click to enlarge
Page 7

CHAPTER 1: INTRODUCTION

1.4 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below.

1.5 Definitions Qualified and/or Authorized Operating Personnel

Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or have had previous experience with the operation of equipment covered in this manual. Qualified Installation Personnel

Qualified installation personnel are individuals, or firms, corporations, or companies, which, either in person or through a representative are engaged in and are responsible for the installation of gas-fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes. Qualified Service Personnel

Qualified service personnel are those who are familiar with Dean equipment and have been authorized by Dean to perform service on Dean equipment. All authorized service personnel are required to be equipped with a complete set of service parts manuals and stock a minimum amount of parts for Dean equipment. A list of Dean Factory Authorized Service Centers (FASCs) was included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Dean warranty on your equipment.

Page 8 of the Frymaster SM50 user manual — 2.1 Receiving and Unpacking Equipment
Page 8 · click to enlarge
Page 8

CHAPTER 2: IMPORTANT INFORMATION

2.1 Receiving and Unpacking Equipment

A. Check that the container is upright. Use an outward prying motion - no hammering - to

remove the carton. Unpack the fryer carefully and remove all accessories from the carton. Do not discard or misplace these, as they will be needed.

B. After unpacking, immediately check the equipment for visible signs of shipping damage. If

damage has occurred, contact the carrier and file the appropriate freight claims. Do not contact the factory. Shipping damage responsibility is between the carrier and the dealer.

If your equipment arrives damaged:

1. File claim for damages immediately, regardless of extent of damage.
2. Visible loss or damage: Be sure this is noted on the freight bill or express receipt and is signed by the person making the delivery.
3. Concealed loss or damage: If damage is unnoticed until equipment is unpacked, notify freight company or carrier immediately, and file a concealed damage claim. This should be done within 15 days of date of delivery. Be sure to retain container and all packing materials for inspection.

C. Remove all plastic skin from sides, front, and doors of the fryer(s). Failure to do this prior to

initial fryer operation will make it very difficult to remove later. 2.2 General Qualified, licensed, and/or authorized installation or service personnel only (as defined in Section 1.5) should perform the following:

  • Installation and service on Dean equipment.
  • Conversion of this appliance from one gas type to another. Failure to use qualified, licensed, and/or authorized installation or service personnel to install, convert to another gas type or otherwise service this equipment will void the Dean warranty and may result in damage to the equipment or injury to personnel. Where conflicts exist between instructions and information in this manual and local code or national codes, or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed.
Page 9 of the Frymaster SM50 user manual — CHAPTER 2: IMPORTANT INFORMATION
Page 9 · click to enlarge
Page 9

CHAPTER 2: IMPORTANT INFORMATION

2.2 General (cont.) Dean Super Marathon Series gas fryers are energy efficient gas-fired units. All units are shipped completely assembled, with accessories packed inside the frypot. All units are adjusted, tested, and inspected at the factory prior to crating for shipment.

WARNING The on-site supervisor is responsible for ensuring that operators are made aware of the inherent dangers of operating a hot-oil fryer/filter system, particularly the aspects of fryer operation, oil filtration, and draining/cleaning procedures. 2.3 Principles of Operation The incoming gas flows through orifices and is mixed with air in the burners to create the correct ratio for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot light. Internal diffusers slow the flame as it goes through the burner tube. This slower and more turbulent flame gives much better heat transfer to the walls of the tubes, thereby heating the oil more efficiently. 2.4 Rating Plate

DANGER Fryers MUST be connected ONLY to the gas type identified on the attached rating plate. The rating plate can be found on the inside panel of the fryer door. Information on this plate includes the model and serial numbers, kW/hr (BTU/hr) of the burners, outlet gas pressure in mbars (inches W.C.), and configuration: natural or propane gas. Rating plate data is essential for proper unit identification, communicating with the factory or requesting special parts and/or information.

Page 10 of the Frymaster SM50 user manual — CHAPTER 2: IMPORTANT INFORMATION
Page 10 · click to enlarge
Page 10

CHAPTER 2: IMPORTANT INFORMATION

2.5 Pre-Installation

1. A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for safety and ease of future service.
2. Dean Super Marathon Series gas fryers operate on millivolts, and do not require an external electric power supply (unless equipped with a built-in filtration system). B. Clearances : The fryer area must be kept free and clear of all combustibles. This unit is design-

certified for the following installations:

1. Commercial installation only (not for household use).
2. Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch (13-cm) casters;
3. Combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches (15-cm) rear, and equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch (13-cm) casters.
Page 11 of the Frymaster SM50 user manual — CHAPTER 2: IMPORTANT INFORMATION
Page 11 · click to enlarge
Page 11

CHAPTER 2: IMPORTANT INFORMATION

2.5 Pre-Installation (cont.) C. Installation Standards

1. CE/EXPORT STANDARDS: Fryer installation must conform with local codes, or in the absence of local codes, to the appropriate national or European Community (CE) standards.
2. NON-CE INSTALLATION STANDARDS: Fryer installation must conform with local codes, or in the absence of local codes, to the appropriate national standards as listed below:
a. U.S. installations must meetb. Canadian installations must meet:

American National Standard Institute CAN 1-B149 Installation Codes ANSI Z83.11 Canadian Gas Association American Gas Association 55 Scarsdale Road 8501 E. Pleasant Valley Road Don Mills, ONT, M3B 2R3 Cleveland, OH 44131 National Electrical Code Canadian Electric Code c22.1, part 1 ANSI/NFPA #70 Canadian Standards Association American National Standard Institute 178 Rexdale Blvd. 1430 Broadway Rexdale, ONT, M9W 1R3 New York, NY 10018 NFPA Standards #96 and #211 National Fire Protection Association 470 Atlantic Avenue Boston, MA 02110

2.6 Equipment Installed at High Altitudes 1. The fryer input rating [BTU/hr (kW/hr)] is for elevations up to 2,000 feet (610-m). For elevations above 2,000 feet (610-m), the rating should be reduced 4-percent for each additional 1,000 feet (305-m) above sea level. 2. The correct orifices are installed at the factory if the operating altitude is known at the time of the customer’s order.

Page 12 of the Frymaster SM50 user manual — CHAPTER 2: IMPORTANT INFORMATION
Page 12 · click to enlarge
Page 12

CHAPTER 2: IMPORTANT INFORMATION

2.7 Air Supply and Ventilation

Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow. 1. Do not connect this fryer to an exhaust duct. 2. Correct installation and adjustment will ensure adequate airflow to the fryer system. 3. A commercial, heavy-duty fryer must vent its combustion wastes to the outside of the building. A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan must be provided in the wall above the unit, as exhaust gas temperatures are approximately 800-1000°F (427-538°C). Check air movement during installation. Strong exhaust fans in the exhaust hood or in the overall air conditioning system can produce slight air drafts in the room. 4. Do not place the fryer’s flue outlet directly into the plenum of the hood, as it will affect the gas combustion of the fryer. 5. Never use the interior of the fryer cabinet for storage or store items on shelving over or behind the fryer. Exhaust temperatures can exceed 800°F (427ºC) and may damage or melt items stored in or near the fryer. 6. Adequate distance must be maintained from the flue outlet of the fryer(s) to the lower edge of the filter bank. Per NFPA Standards No. 96, a minimum of 18-inches (45-cm) should be maintained between the flue(s) and the lower edge of the exhaust hood filter. 7. Filters and drip troughs should be part of any industrial hood, but consult local codes before constructing and installing any hood. The duct system, the exhaust hood and the filter bank must be cleaned on a regular basis and kept free of grease. 2.8 Conversion of Units

Pressure: 1 mbar = 10,2 mm W.C. = 0,4-inch W.C. 20 mbar = 204 mm W.C. = 8-inch W.C. 1-inch W.C. = 25,4 mm W.C. = 2,5 mbar Heat Input: 1 kW = 3410 BTU/hr 100 BTU/hr = 0,0293 kW Temperature: 0° Celsius = 32° Fahrenheit Temperature in degrees Celsius = (Temperature in degrees Fahrenheit (F) – 32) x 0,555 100° Celsius = (212° Fahrenheit – 32) x 0,555

Page 13 of the Frymaster SM50 user manual — 2.7 Air Supply and Ventilation
Page 13 · click to enlarge
Page 13

3.1 Installing the Fryer A. Initial Installation: If installed with legs, do not push against the fryer’s side to adjust its

position. Use a pallet or lift jack to lift the fryer slightly and place it where it is to be installed. B. Relocating the Fryer: If relocating a fryer installed with legs, remove all weight from each leg

before moving. NoteIf a leg becomes damaged during movement, contact your service agent for immediate

repair/replacement.

Frymaster SM50 — 2.7 Air Supply and Ventilation diagram (page 13)
Fig. 12 · 2.7 Air Supply and Ventilation
Frymaster SM50 — 2.7 Air Supply and Ventilation diagram (page 13)
Fig. 13 · 2.7 Air Supply and Ventilation
1. Install legs and rear rigid casters near where the fryer is to be used, as neither is secure for long transit. Unit cannot be curb mounted and must be equipped with the legs and casters provided.
2. When positioning the fryer, gently lower the fryer into position to prevent undue strain to the legs and internal mounting hardware. Use a pallet or lift jack to lift and position the fryer if possible. Tilting the fryer may damage the legs.
Page 14 of the Frymaster SM50 user manual — 2.7 Air Supply and Ventilation
Page 14 · click to enlarge
Page 14

3.2 Leg and Caster Installation (cont.)

3. Rigid casters must be installed on the fryer rear-channel assembly only.
4. Proceed to Step 3.3, Leveling the Fryer, after legs and rear rigid casters are installed to ensure the fryer is level before using. B. Leg and Rigid Caster Installation
1. Remove unit from pallet.
2. Carefully raise unit with forklift, pallet jack, or other steady means.
3. Place one lock washer on each hex head screw.
4. Insert hex head screws with lock washers [1/4-20 threads by ¾" (19 mm) long] through bolt holes of leg mounting plates and mount to the front channel. Mount rigid casters to the rear channel following the same procedure. A locknut has been attached to the topside of the base mounting plates at the factory to capture the hex head screw as it is screwed in.
5. Tighten the bolts to 50 inch-lbs. (5.65 Nm) torque. 3.3 Leveling the Fryer A. Place a carpenter’s level across the top of the fryer and level the unit front to back. If the fryer is

not level from side to side, a platform or other surface adjustment is needed; there is no side-to- side level adjustment on a fryer equipped with caster/leg combinations. (If a fryer is equipped with legs only, side-to-side level adjustments can be made. If a fryer is equipped with casters only, no level adjustments can be made.). If the fryer is not level, the unit may not function efficiently, the oil may not drain properly for filtering and in a multi-fryer battery, it may not match adjacent units.

1. Adjust leg height with an adjustable or 1-1/16-inch (27 mm) open-end wrench by turning the hex bullet on the bottom of the leg.
2. The hex bullet is for minor leg height adjustment only. Do not adjust more than 1-inch (25.4 mm) .
3. When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the hex bullet foot to the required height.

Legs (Only)

Page 15 of the Frymaster SM50 user manual — 3.3 Leveling the Fryer (cont.) Rigid Casters (Only)
Page 15 · click to enlarge
Page 15

3.3 Leveling the Fryer (cont.) Rigid Casters (Only)

1. Install the rigid casters on the fryer rear channel only. Legs must be installed on the front channel.
2. There are no level adjustments for the rigid casters. B. If the floor is uneven or has a decided slope, place the fryer on a smooth, level platform.

C. If the fryer is moved, re-level the fryer following the instructions given in Steps 3.3, A-C.

D. An installed fryer must be restrained to prevent tipping, which could splash hot oil. Restraints

can be straps or chains anchored to an immovable object (wall, floor anchor), or the manner of installation (installing the fryer in an alcove, battering to other appliances, etc.).

Page 16 of the Frymaster SM50 user manual — 3.3 Leveling the Fryer (cont.) Rigid Casters (Only)
Page 16 · click to enlarge
Page 16

3.3 Leveling the Fryer (cont.) NOTE: The installation must be inspected after it is complete to ensure it meets the intent of these instructions. The on-site supervisor and/or operator(s) should be informed that the appliance is installed with restraints. If restraints are removed to move fryer (cleaning beneath and behind, relocation, etc.), ensure that they are re-installed when fryer is returned to its permanently installed position.

Frymaster SM50 — 3.3 Leveling the Fryer (cont.) Rigid Casters (Only) diagram (page 16)
Fig. 14 · 3.3 Leveling the Fryer (cont.) Rigid Casters (Only)
Frymaster SM50 — 3.3 Leveling the Fryer (cont.) Rigid Casters (Only) diagram (page 16)
Fig. 15 · 3.3 Leveling the Fryer (cont.) Rigid Casters (Only)

I2E(R)B G20/G25 20/25 BELGIUM (BE) I3+ G30/G31 28-30/37 DENMARK (DK)

ITALY (IT) IRELAND (IE) PORTUGAL (PT) UNITED KINGDOM (GB)

Page 17 of the Frymaster SM50 user manual — NOTICE
Page 17 · click to enlarge
Page 17

3.4 Gas Connections (cont.) NATIONAL CODE REQUIREMENTS: NON-CE This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration. This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect equipment stamped "NAT" only to natural gas and that stamped "PRO" only to LP (Propane) gas. Australia Only: Installation is to be in accordance with the requirements of AS5601/AG601, local regulatory authority requirements and other statutory regulations.

NOTICE

Page 18 of the Frymaster SM50 user manual — NOTICE
Page 18 · click to enlarge
Page 18

3.4 Gas Connections (cont.) Supply Line Specifications The incoming gas supply line should be a minimum of 1½" (40 mm) in diameter. The gas supply lines must be sized as indicated in the chart below, based on the total number of fryers connected to the main gas supply.

Recommended Gas Connection Line Sizes Gas Types Number of Fryers 1 2 to 3 4 or 5 (*) Natural Gas 3/4" (20 mm) 1" (25 mm) 1-1/4" (32 mm) Propane Gas 1/2" (15 mm) 3/4" (20 mm) 1" (25 mm) (*) When exceeding 18 feet (6 meters) for a configuration of four to five fryers, it is necessary to

provide a 1-¼" (32 mm) rigid gas connection. For six or more fryers, contact factory for connection line specifications.

DANGER All connections must be sealed with a joint compound suitable for the gas being used and all connections must be tested with a solution of soapy water before lighting any pilots. Never use matches, candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply to the appliance at the main shut-off valve and immediately contact the local gas company or an authorized service agency for service.

DANGER "Dry-firing" your unit will cause damage to the frypot and can cause a fire. Always ensure that melted shortening, cooking oil or water is in the frypot before firing the unit. Rigid Connections Check any installer-supplied intake pipe(s) visually and clean metal particles or other foreign matter from the threads before installing into a service line. If the intake pipes are not clear of all foreign matter, the orifices will clog when gas pressure is applied. When using thread compound on gas piping, use very small amounts and only on male threads. Use a pipe thread compound that is not affected by the chemical action of LP gases. DO NOT apply thread compound to the first two pipe threads – doing so will cause clogging of the burner orifices and control valve. Manual Shut-Off Valve This gas service supplier-installed valve must be installed in the gas service line ahead of the fryers in the gas stream and in a position where it can be reached quickly in the event of an emergency.

Page 19 of the Frymaster SM50 user manual — NOTICE
Page 19 · click to enlarge
Page 19

3.4 Gas Connections (cont.) Regulating Gas Pressure The fryer and shut-off valve must be disconnected from the gas supply during any pressure testing of the system. External gas regulators are not normally required on this fryer. A safety control valve protects the fryer against pressure fluctuations. If the incoming pressure is in excess of ½" PSI (3.45 kPa/35 mbar), a step-down regulator will be required.

1. Check the rating plate for manifold gas pressures. Natural gas units normally require 4inches W.C. (10 mbars), and propane units normally require 11-inches W.C. (27 mbars) gas pressure.
2. Confirm that the arrow forged into the bottom of the regulator body, which indicates gas flow direction, is pointed downstream towards the fryers. The air vent cap is also part of the regulator and should not be removed.
3. If a vent line from the gas pressure regulator is used, it should be installed in accordance with local codes or in the absence of local codes, with the appropriate national or European Community (CE) standards.

the regulator is out of adjustment, or serious pressure fluctuations are observed.

C. Only qualified service personnel should make adjustments to the regulators. D. Orifices: The fryer can be configured to operate on any available gas. The correct safety control

valve, appropriate gas orifices, and pilot burner are installed at the factory. While the valve can be adjusted in the field, only qualified service personnel should make any adjustments with the proper test equipment.

Page 20 of the Frymaster SM50 user manual — 3.4 Gas Connections (cont.)
Page 20 · click to enlarge
Page 20

3.4 Gas Connections (cont.)

1. CE ONLY: The following color codes indicate the type of gas to be used for each fryer and associated components.

Gas Type CE Color Code Natural Blue Propane Red E. Flexible Couplings, Connectors and Casters

1. If the fryer is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must use a heavy-duty certified commercial flexible connector of at least 3/4" (22 mm) NPT (with suitable strain-relief attachments), in compliance with local codes or in the absence of local codes, with the appropriate national or European Community (CE) standards. Quick-disconnect devices must comply with local codes or in the absence of local codes, with the appropriate national or European Community (CE) standards.
2. For an appliance equipped with casters, the installation shall be made with a connector that complies with local codes or in the absence of local codes, with the appropriate national or European Community (CE) standards.
3. Under no circumstances are the connector and the quick-disconnect device, or its associated piping to be used to limit fryer movement. A restraining bracket is provided on the appliance back to prevent the unit from moving from its installed position.
4. To limit movement of the fryer, restraints independent of the flexible coupling or connector must be used. Clips are located on the back panel of the fryer for the attachment of restraints. 5. If disconnection of the restraint is necessary, the restraint must be reconnected after the fryer has been returned to the position it was originally installed. F. After hook up, bleed the gas line of air to ensure that the pilot light will ignite quickly and

evenly.

Page 21 of the Frymaster SM50 user manual — 3.4 Gas Connections (cont.)
Page 21 · click to enlarge
Page 21

3.5 Adjustments/Adaptation To Different Gases A. Proper operation of appliances requires operator to inspect the following adjustments in Section

3.6 in terms of gas inputs and pressures. B. Dean Super Marathon Series gas fryers are manufactured to use the type of gas and pressure

specified on the rating plate. When changing gas, adaptation must be performed by qualified personnel. Failure to use qualified personnel will void the Dean warranty.

DANGER This appliance was configured at the factory for a specific type of gas. Converting from one gas type to another requires the installation of specific gas-conversion components. Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED! Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.5 of this manual.

Page 22 of the Frymaster SM50 user manual — 3.4 Gas Connections (cont.)
Page 22 · click to enlarge
Page 22

3.6 Gas Inputs CE UNITS ONLY: A. Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Part Number and Quantity/Color are listed in

the table below:

Frymaster SM50 — 3.4 Gas Connections (cont.) diagram (page 22)
Fig. 16 · 3.4 Gas Connections (cont.)

SM 35 GM SM 40 GM 26 G20 G25 G31

2/BLUE 2/BLUE 2/RED B. Adjustments for different gases are as follows:

Frymaster SM50 — 3.4 Gas Connections (cont.) diagram (page 22)
Fig. 17 · 3.4 Gas Connections (cont.)

26N 26N 16LP *SM prefix- Super Marathon Series *GM suffix- gas millivolt system with no electrical supply connections required (1) The Netherlands (NL) only.

Page 23 of the Frymaster SM50 user manual — 3.4 Gas Connections (cont.)
Page 23 · click to enlarge
Page 23

3.6 Gas Inputs (cont.) NON-CE ONLY: A. Nominal Heat Inputs (Qn), Gas Type, Orifice Size (applicable for fryer operation at altitudes of

2000 feet or less), Part Number and Quantity are listed in the table below:

Frymaster SM50 — 3.4 Gas Connections (cont.) diagram (page 23)
Fig. 18 · 3.4 Gas Connections (cont.)

2.53(#39) 1.51(#53) 810-2048 810-2059 4 4 SM 35 GM SM 40 GM 105 NAT

2.18(#44) 1.40(#54) 810-2050 810-0710 2 2 B. Adjustments for different gases are as follows:

Frymaster SM50 — 3.4 Gas Connections (cont.) diagram (page 23)
Fig. 19 · 3.4 Gas Connections (cont.)

Manifold Gas Pressure [Inches W.C. (mbar)]* 4" W.C. (10 mbars) 11" W.C. (27.5 mbars)

* For controls and adjustments, please refer to gas valve illustration on page 3-14. (Pilot Flame Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame- volume is achieved).

Page 24 of the Frymaster SM50 user manual — 3.7 Gas Conversion Procedures
Page 24 · click to enlarge
Page 24

3.7 Gas Conversion Procedures

DANGER This appliance was configured at the factory for a specific type of gas. Converting from one gas type to another requires the installation of specific gas-conversion components. Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED! Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.5 of this manual. CE UNITS ONLY: See page 3-13 for gas valve illustration and gas valve, burner and orifice location when performing the following conversions. When converting from G20 to G25 gas, the following procedures apply:

♦ Equipment replacement is not required. ♦ Adjust orifice gas pressure to the appropriate value listed in the table on page 3-10 by turning the gas valve "adjustment screw". ♦ After adjustment, replace the adjustment-screw cover. When converting from G20 (or G25) gas to G31 propane (or vice-versa), the following procedures apply:

♦ Burner orifices and pilot orifice MUST be replaced. ♦ Adjust orifice gas pressure to the appropriate value listed in the table on page 3-10 by turning the gas-valve adjustment screw. ♦ After adjustment, replace the adjustment-screw cover. ♦ Affix the new rating plate included with the conversion kit. If a new rating plate was not included contact your local FASC to obtain one. When converting from G20 (20 mbar) to G25 (25 mbar), or vice-versa, the following procedures apply:

♦ Check pilot-adjustment and adjust as necessary. ♦ Other adjustments are not necessary.

Page 25 of the Frymaster SM50 user manual — 3.7 Gas Conversion Procedures
Page 25 · click to enlarge
Page 25

3.7 Gas Conversion Procedures (cont.) Conversion from one gas family to another (i.e. changing from natural gas to propane) requires special components. Obtain the necessary components using the cross-reference in Section 3.8, Gas Conversion Components. Conversions can only be executed by qualified, factory-authorized personnel.

Frymaster SM50 — 3.7 Gas Conversion Procedures diagram (page 25)
Fig. 20 · 3.7 Gas Conversion Procedures

Typical gas valve, burner and orifice locations (SM35 shown above).

Page 26 of the Frymaster SM50 user manual — 3.7 Gas Conversion Procedures
Page 26 · click to enlarge
Page 26

3.7 Gas Conversion Procedures (cont.) NON-CE UNITS ONLY: See gas valve illustration below and gas valve, burner and orifice location on page 3-15 when performing the following conversions. When converting from natural gas to propane (or vice-versa), the following procedures apply:

♦ Burner orifices and pilot orifice MUST be replaced (see page 3-11 for required component part numbers). ♦ Adjust orifice gas pressure by turning the gas-valve adjustment screw (see page 3-11 for gas types and pressures). ♦ After adjustment, replace the adjustment-screw cover. ♦ Affix the new label included with the conversion kit next to the existing rating plate stating that the gas type has been converted. Remove any references to the previously used gas from the existing rating plate. Conversion from one gas family to another (i.e. changing from natural gas to propane) requires special components. Obtain the necessary components using the tables on page 3-11. Conversions can only be executed by qualified, factory-authorized personnel.

Frymaster SM50 — 3.7 Gas Conversion Procedures diagram (page 26)
Fig. 21 · 3.7 Gas Conversion Procedures

Pressure flow adjustment (remove cover screw to access)

Regulator Vent Pilot pressure adjustment (remove cover screw to access)

Pilot gas supply connection

Typical gas valve (Millivolt- Non-CE).

ON/PILOT/OFF Gas-Cock Knob · Pressure Tap

Page 27 of the Frymaster SM50 user manual — 3.7 Gas Conversion Procedures
Page 27 · click to enlarge
Page 27

3.8 Gas Conversion Components Use the following components to convert from natural gas to propane and vice-versa. See Section 3.6 for orifice quantities required for conversion.

Frymaster SM50 — 3.7 Gas Conversion Procedures diagram (page 27)
Fig. 22 · 3.7 Gas Conversion Procedures

Natural Gas to Propane Components Propane To Natural Gas Components

Burner orifice* (See Tables on Page 3-10 – 3-11)

Burner orifice* (See Table on Page 3-10 – 3-11)

* Burner orifices listed on page 3-10 – 3-11 are for fryers operating at altitudes of 2000 feet (610 meters) or less. For altitudes greater than 2000 feet (610 meters), contact the factory for the correct orifice size. 3.9 Electrical Connections Fryers without built-in filtration do not require electrical connection. Fryer systems with built-in filtration when installed must be electrically grounded in accordance with local codes, or in the absence of local codes, with the appropriate national standards.

Frymaster SM50 — 3.7 Gas Conversion Procedures diagram (page 27)
Fig. 23 · 3.7 Gas Conversion Procedures

For fryers with built-in filtration systems: The rating plate and wiring diagram are located on the inside front door panel. Built-in filtration systems are equipped with 120VAC single-phase 60-hertz system (Domestic), or 230VAC single-phase 50-hertz system (International/CE). Do not cut or remove the ground prong from the power cord plug.

Frymaster SM50 — 3.7 Gas Conversion Procedures diagram (page 27)
Fig. 24 · 3.7 Gas Conversion Procedures
Page 28 of the Frymaster SM50 user manual — 4.1 Initial Start-up
Page 28 · click to enlarge
Page 28

CHAPTER 4: FRYER OPERATIONS

4.1 Initial Start-up

Frymaster SM50 — 4.1 Initial Start-up diagram (page 28)
Fig. 25 · 4.1 Initial Start-up

WARNING The on-site supervisor is responsible for ensuring that operators are made aware of the inherent hazards of operating a hot oil frying system, particularly the aspects of system operation, oil filtration, draining and cleaning procedures. Cleaning: New units are wiped clean with solvents at the factory to remove any visible signs of dirt, oil, grease, etc. remaining from the manufacturing process, then coated lightly with oil. Before any food preparation, wash thoroughly with hot, soapy water to remove any film residue and dust or debris then rinse out and wipe dry. Also wash any accessories shipped with the unit. Close the drain valve completely and remove the crumb screen covering the heating tubes. Ensure the screws holding the thermostat and high-limit control sensing bulbs into the frypot are tight.

Frymaster SM50 — 4.1 Initial Start-up diagram (page 28)
Fig. 26 · 4.1 Initial Start-up
Frymaster SM50 — 4.1 Initial Start-up diagram (page 28)
Fig. 27 · 4.1 Initial Start-up

Typical frypot drain valve (SM40 shown).

Typical high-limit/sensor probe location and mounting hardware.

Page 29 of the Frymaster SM50 user manual — ON
Page 29 · click to enlarge
Page 29

CHAPTER 4: FRYER OPERATIONS

4.1.1 Pilot Lighting Procedures, Standing Pilot Only Initial Pilot Lighting: All Dean fryers are tested, adjusted and calibrated to sea level conditions before leaving the factory. Adjustments to assure proper operation of pilot may be necessary on installation to meet local conditions, low gas pressure, differences in altitude and variations in gas characteristics. These adjustments correct possible problems caused by rough handling or vibration during shipment, and are to be performed only by qualified service personnel. These adjustments are the responsibility of the customer and/or the dealer and are not covered by the Dean warranty. The inlet pipe at the lower rear of the fryer brings incoming gas to the pilot safety control valve, then to the pilot and main burners. The pilot is located high in the cabinet center, at the base of the frypot.

Frymaster SM50 — CHAPTER 4: FRYER OPERATIONS diagram (page 29)
Fig. 28

PILOT

PILOT

OFF

OFF

Frymaster SM50 — PILOT diagram (page 29)
Fig. 29

ON

ON

PILOT Position ON Position Non-CE Gas Valve Perform the following steps in sequence before lighting or re-lighting the pilot: 1. Turn the operating thermostat "OFF". 2. For CE units: Depress the Pilot Off button (red) on the safety control valve to turn "OFF". For Non-CE units: Depress and turn the gas valve knob to the OFF position. 3. Wait at least 5 minutes for any accumulated gas to disperse.

Honeywell CE Gas Valve

NOTE: Inspect high-limit thermostat/temperature probe locations prior to filling frypot with water or oil. Ensure that connecting hardware is intact and bulbs are properly attached. 4. Fill the frypot with oil or water to the bottom OIL LEVEL line scribed on the frypot back. Ensure heating tubes are covered in liquid prior to engaging burners. 5. Open the manual shut-off valve on the incoming service line. For Non-CE units: Rotate the gas valve knob to the pilot position. If fryer is equipped with a piezo ignitor, go to Step 9.

Page 30 of the Frymaster SM50 user manual — CHAPTER 4: FRYER OPERATIONS
Page 30 · click to enlarge
Page 30

CHAPTER 4: FRYER OPERATIONS

4.1.1 Pilot Lighting Procedures, Standing Pilot Only (cont.) 6. For CE units: Apply a lighted match or taper to the pilot burner head. Press the white pilot light button on the gas valve and hold approximately 45 seconds to 1 minute, until the pilot stays lit. For Non-CE units: Push and hold the knob in and apply a lighted match or taper to the pilot burner head. Continue to hold the knob in for about 60 seconds after the flame appears on the pilot. Release the knob. The pilot should remain lit. 7. If fryer is equipped with a piezo ignitor, press and hold the white pilot light button, then repeatedly press the piezo ignitor button until the pilot lights. Release the white button after approximately 45 seconds to 1 minute.

8. If the pilot does not stay lit, depress the white pilot light button and re-light the pilot, holding the button in longer before releasing. Trapped air may necessitate re-lighting the pilot several times until a constant gas flow is attained. 9. When the pilot stays lit, release the white pilot light button. 4.2 Boil-Out Procedure

Pour cleaning solution into the frypot and add water to the top OIL LEVEL line scribed in the back of the frypot.

Set the operating thermostat dial to 225°F (107ºC), just above that of boiling water.

A. The main burner will ignite.

B. When the solution nears the boiling point, reset the temperature controller to 200°(93ºC).

C. The burners should shut off just as the water starts to boil.

Page 31 of the Frymaster SM50 user manual — CHAPTER 4: FRYER OPERATIONS
Page 31 · click to enlarge
Page 31

CHAPTER 4: FRYER OPERATIONS

4.2 Boil-Out Procedure cont. D. The burners will heat the boil-out solution to a simmer. Simmer the solution for approximately

45 minutes. Wearing protective gloves, scrub the sides of the frypot and the tubes with the L- shaped Teflon brush, being careful not to disturb the temperature sensing probes and the high- limit thermostat.

E. Do not allow the water level to decrease below the top OIL LEVEL line in frypot during boil-

out operation.

F. After boil out is complete, turn the thermostat dial to "OFF" and drain the solution from the

frypot. Place a metal stockpot of sufficient size to safely hold the entire contents of the frypot under the drain port to collect the water/boil-out solution. G. Filtration Equipped Units: Do not allow water or boil-out solution to drain into the filter pan.

The filter pump is not designed for water operation, and will be irreparably damaged. H. Close the drain, add fresh water (without boil-out solution) and wash all surfaces of the frypot.

Drain again.

I. Refill the frypot with fresh water and vinegar to neutralize any residual boil-out solution.

Wash all surfaces of the frypot. Drain completely and wipe down all surfaces of the frypot to completely remove all water. NOTE: It is recommended that the boil-out procedure be performed each time the oil is changed.

Page 32 of the Frymaster SM50 user manual — CHAPTER 4: FRYER OPERATIONS
Page 32 · click to enlarge
Page 32

CHAPTER 4: FRYER OPERATIONS

4.3 Final Preparation

4.3.1 Filling the Fryer with Oil or Shortening A. When using liquid shortening or cooking oil, fill the fryer to the bottom OIL LEVEL line

scribed into the back of the frypot. B. When using a solid shortening, cut it into small pieces and pack it below, between and above

the heat tubes, leaving no air spaces around the tubes. Do not disturb or bend the sensing bulbs. C. After the shortening is packed around the tubes, turn the burners "ON" for about 10 seconds,

"OFF" for a minute, etc., until the shortening is melted. If you see smoke coming from the shortening during the melting process, shorten the "ON" cycle and lengthen the "OFF" cycle. Smoke indicates potential scorching of the shortening, which will shorten its useful life. D. Before starting operation, turn the operating thermostat to the probable working temperature;

wait for the temperature to stabilize then check with a high-quality immersion thermometer. For filtration instructions and troubleshooting, consult the operating manual or instructions provided with the filtration equipment.

4.3.2 Extending Shortening/Oil Life Although 350°F (177°C) is the recommended temperature for most cooking operations, set the fryer at the lowest possible temperature which produces a high quality product. This ensures maximum life of shortening. When the fryer is not in use, set the thermostat to a lower temperature from that used during cooking. Light loads may be cooked at lower temperatures. Experiment to determine the optimum temperature and load conditions for various food items being cooked.

Page 33 of the Frymaster SM50 user manual — 5.1 General
Page 33 · click to enlarge
Page 33

SUPER MARATHON SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE

5.1 General

Frymaster SM50 — 5.1 General diagram (page 33)
Fig. 30 · 5.1 General

Any equipment works better and lasts longer when maintained properly and kept clean. Cooking equipment is no exception. Super Marathon Series gas fryers should be kept clean during the working day and thoroughly cleaned at the end of each day. Below are recommendations for daily, weekly and periodic preventative maintenance.

5.1.1 Daily

Frymaster SM50 — 5.1 General diagram (page 33)
Fig. 31 · 5.1 General

A. Remove and wash all removable parts.

B. Clean all exterior surfaces of the cabinet. Do not use cleaners, steel wool, or any other

abrasive material on stainless steel.

C. Filter the cooking oil and replace if necessary. The oil should be filtered more frequently

when under heavy use. 5.1.2 Weekly

A. Completely drain the oil from the fryer into a metal stockpot of sufficient size to safely hold

the entire contents of the frypot for disposal. Do not use a glass or plastic container.

B. Clean the frypot by following boil-out procedures in Chapter 4-2.

Frymaster SM50 — 5.1 General diagram (page 33)
Fig. 32 · 5.1 General
Page 34 of the Frymaster SM50 user manual — SUPER MARATHON SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE
Page 34 · click to enlarge
Page 34

SUPER MARATHON SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE

  • 5.1.3 Periodic/ Annual The fryer should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program. Dean recommends that the fryer be inspected at least annually by a Factory Authorized Service Technician as follows:
  • Inspect fryer cabinet inside and out, front and rear, for excessive oil build-up and/or oil migration. Verify that burners and associated components (i.e. gas valves, pilot assemblies, piezo ignitors, etc.) are in good condition and functioning properly. Inspect all gas connections for leaks and ensure all connections are properly tightened.
  • Verify that temperature and high-limit probes are properly connected, tightened and functioning properly.
  • Verify that all electronic components (i.e. computer/controller, relays, transformers, interface boards, etc.) are in good condition and free from oil migration build-up and other debris. Inspect any wiring and ensure all connections are tight and all wiring is in good condition. Ensure all safety features (i.e. drain safety switches, reset switches, etc.) are present and functioning properly.
  • Verify that frypot is in good condition and free of leaks. Verify that frypot tube diffusers are present and in good condition (i.e. no visible deterioration or damage).
  • Verify that all wiring and connections are tight and in good condition. See filtration manual for filtration maintenance procedures. 5.1.4 Stainless Steel Care

A. Do not use steel wool, abrasive cloths, cleansers or powders.

B. Do not use a metal knife, spatula or any other metal tool to scrape stainless steel! Scratches

are almost impossible to remove.

C. If it is necessary to scrape the stainless steel to remove any encrusted materials, soak the area

first to soften the deposit, then use a wood or nylon scraper only.

Page 35 of the Frymaster SM50 user manual — 6.1 General
Page 35 · click to enlarge
Page 35

CHAPTER 6: TROUBLESHOOTING

6.1 General

DANGER Hot cooking oil will cause severe burns. Never attempt to move this appliance when filled with hot cooking oil or to transfer hot cooking oil from one container to another. The problems and possible solutions covered are those most commonly encountered. To troubleshoot, perform the test set-up at the beginning of each condition. Follow each step in sequence. 6.2 Pilot Burner Malfunction

A. Pilot will not ignite. No evidence of gas at pilot burner.

1. Check that incoming service line gas valve is open and gas is present at the gas valve.
2. Check pilot burner orifice for dirt or lint.
3. Remove pilot burner gas-supply line and check for contamination; blow out if necessary, then reinstall.

B. Pilot burner ignites but will not remain lit when gas valve manual knob is released (Non-CE),

or the pilot button is released (CE).

1. For CE units: Check that thermocouple lead is properly screwed into thermocouple connection bushing on gas valve.
2. For CE units: Remove end of thermocouple lead from thermocouple connection bushing and clean with fine sandpaper or emery cloth. 3. Check the thermopile leads where they connect to the gas valve making sure that the connection is clean and tight.
4. Pilot flame may be too high or too low. Adjust pilot flame adjustment screw so that pilot flame extends about ¾-inch (22-mm) above the top of the pilot burner.
5. Check all connections for cleanliness and security.

C. Pilot flame of proper size, but is unstable. Flame wavers and does not envelope the

thermocouple completely at all times.

1. Check for drafts that might be caused by air conditioning equipment or make-up air apparatus. Turn air-moving equipment off and recheck the pilot.
Page 36 of the Frymaster SM50 user manual — CHAPTER 6: TROUBLESHOOTING
Page 36 · click to enlarge
Page 36

CHAPTER 6: TROUBLESHOOTING

6.3 Main Burner Malfunctions

A. Main burner will not come "ON"; gas not detected at main burner.

1. Check that the gas valve is open.
2. Check that the pilot is lit and is operating properly.
3. Check the high-limit switch for continuity.
4. The combination gas valve may be defective; replace if necessary.

B. Main burner flames are small and appear lazy; shortening does not come up to temperature

quickly.

1. Check gas pressure at the pressure tap of the gas valve. Use dial type or standard watertype U-gauge manometer. With burner in operation, the pressure should match the pressures listed in the tables on page 3-10 – 3-11.
2. If not, remove the pressure regulator adjustment cover. Use a screwdriver to turn the adjusting screw for proper pressure. Replace cover, re-check pressure and re-install pressure regulator adjustment cover.

C. Signs of excessive temperature: shortening scorches and quickly becomes discolored.

1. Check operating thermostat. May be out of adjustment or calibration. Recalibrate if necessary.
2. Check gas pressure as outlined above.
3. Shortening used is of inferior quality and/or shortening has been used too long. Replace shortening.
4. Ensure frypot is clean when refilling with new shortening.

D. Fryer will not reach the temperature setting and/or runs erratically.

1. s-1.25 TD 0 Tc 0 Tw ( )
Page 37 of the Frymaster SM50 user manual — HONEYWELL
Page 37 · click to enlarge
Page 37

CHAPTER 6: TROUBLESHOOTING

6.4 Wiring Diagrams CE UNITS ONLY:

PP TH

PP TH

THERMOPILE HONEYWELL 807-3565

OPERATING THERMOSTAT

COAXIAL LEAD TO THERMOCOUPLE 812-1284

HIGH-LIMIT

HONEYWELL CE

NON-CE UNITS ONLY:

CONTROL CIRCUIT

Vent Valve Combination Gas

PILOT

GENERATOR

PILOT ADJ.

1/2 P.S.I.

PILOT KNOB

HONEYWELL

HONEYWELL 1/2 P.S.I.

PILOT

ON

TH TP TH

1/2 P.S.I.

HONEYWELL

TP

OFF

N/O COM N/C

THERMOPILE

HI

LIMIT

THERMOSTAT OPERATING

Honeywell Millivolt Gas Valve Wiring

Robertshaw Millivolt Gas Valve Wiring

Show 14 more labels / short text on this page
Robertshaw · Operating · Thermostat · Black · Red Black · Black · Safety Valve · Red · Red · Red · Yellow (Braided) · Orange (Braided) · Black Red · Red
Page 38 of the Frymaster SM50 user manual — CHAPTER 6: TROUBLESHOOTING
Page 38 · click to enlarge
Page 38

CHAPTER 6: TROUBLESHOOTING

6.5 Recommended Spare Parts CE UNITS ONLY: Commonly replaced parts in CE Super Marathon Series gas fryers are: Gas Valve (Honeywell)- Natural- 807-2122 Gas Valve (Honeywell)- LP- 807-2121 High-Limit Thermostat- Manual Reset (CE- 210°C)- 807-3560 Thermopile- 807-3485 Thermocouple- 812-1284 Thermostat, Operating- 807-1692 Knob, Thermostat- 816-0139 NON-CE UNITS ONLY: Commonly replaced parts in Non-CE Super Marathon Series gas fryers are: Gas Valve (Honeywell)- Natural- 807-1603 Gas Valve (Honeywell)- LP- 807-1604 Gas Valve (Robertshaw)- Natural- 807-3645 Gas Valve (Robertshaw)- LP- 810-2399 High-limit Thermostat- 435°F Automatic Reset- 807-3516 High-limit Thermostat- 450°F Manual Reset- 807-3680 Thermopile- 810-2033 Thermostat, Operating- 826-2013 Knob, Thermostat- 810-2035

Page 39 of the Frymaster SM50 user manual — THIS PAGE INTENTIONALLY LEFT BLANK
Page 39 · click to enlarge
Page 39

THIS PAGE INTENTIONALLY LEFT BLANK

Page 40 of the Frymaster SM50 user manual — 819-6001 PRINTED IN THE UNITED STATES SERVICE HOTLINE
Page 40 · click to enlarge
Page 40
Frymaster SM50 — 819-6001 PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 40)
Fig. 33

Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000

Shipping Address8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 FAX (Tech Support) 1-318-219-7135

819-6001 PRINTED IN THE UNITED STATES SERVICE HOTLINE

1-800-551-8633 MAY 2006

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Frymaster SM50

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster SM50

Be the first to ask — other owners or our team will answer.

Original document

Frymaster SM50 manual PDF

40 pages·543 KB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…