IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY, OR DEATH. READ THE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING, OPERATING, OR SERVICING THIS EQUIPMENT.
FOR YOUR SAFETY, DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
DANGER FRYMASTER EQUIPMENT IS MANUFACTURED FOR USE WITH THE TYPE VOLTAGE SPECIFIED ON THE EQUIPMENT RATING PLATE. FOR PROPER ELECTRICAL INSTALLATION PROCEDURES IN THE UNITED STATES, REFER TO THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE (ANSI/N.F.P.A. NO 70). IN CANADA, REFER TO THE CANADIAN ELECTRICAL CODE PART 1 (CSA-22.1.) FOR INSTALLATION IN COUNTRIES OTHER THAN THE UNITED STATES AND CANADA, REFER TO THE NATIONAL CODE APPROPRIATE FOR THE COUNTRY IN WHICH THE EQUIPMENT IS BEING INSTALLED.
COMPUTERS
FCC This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications. Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe a et b prescrites dans la norme NMB-003 edictee par le ministre des communications du Canada.
HAZARD COMMUNICATION STANDARD (HCS) – WHEN THE PROCEDURES IN THIS MANUAL INCLUDE THE USE OF CHEMICAL PRODUCTS, THE PRODUCTS WILL BE PRINTED IN BOLD FACE, FOLLOWED BY THE ABBREVIATION HCS IN THE TEXT PORTION OF THE PROCEDURE. SEE THE HAZARD COMMUNICATION STANDARD (HCS) MANUAL FOR THE APPROPRIATE MATERIAL SAFETY DATA SHEET (MSDS).

CHAPTER 1: INTRODUCTION
1.1 Parts Ordering and Service Information In order to assist you as quickly as possible, the Frymaster Factory Authorized Service Center (FASC) or Ser- vice Department representative requires certain specific information about your equipment. Most of this in- formation is printed on a data plate affixed to the upper right corner of the right side of your unit. Parts orders may be placed directly with your local FASC or distributor. Included with your unit when shipped from the factory is a list of Frymaster FASCs. If you do not have access to this list, contact the Frymaster Service Department at 1-800-24-FRYER. When ordering parts, the following information is required:
Model Number:
Serial Number:
Quantity Needed: Service information may be obtained by contacting your local FASC or Distributor. Service may also be ob- tained by calling the Frymaster Service Department at 1-800-24-FRYER. When requesting service, please have the following information ready:
Model Number:
Serial Number:
Voltage: In addition to the model number, serial number, and voltage, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem. 1.2 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the one below.
DANGER Example of a DANGER box. CAUTION boxes contain information about actions or conditions that may cause or result in a malfunction of your unit. WARNING boxes contain information about actions or conditions that may cause or result in damage to your unit, and which may cause your unit to malfunction. DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your unit and/or cause your unit to malfunction. 1.3 Equipment Description

The McDonald’s Single Basket Dispenser (SinBaD) is designed to dispense french fries in batches of consistent weight into standard fryer baskets. A SinBaD unit consists of • a hopper which holds up to 39 lbs./17.5 kg of fries

1.6 Shipping Damage Claim Procedure Your equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsibility for safe delivery upon its acceptance of the equipment for transport. What to do if your equipment arrives damaged: 1. File a claim for damages immediately, regardless of the extent of damages. 2. Inspect for and record all visible loss or damage, and ensure that this information is noted on the freight bill or express receipt and is signed by the person making the delivery. 3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be recorded and reported to the freight company or carrier immediately upon discovery. A concealed damage claim must be submitted within 15 days of the date of delivery. Ensure that the shipping container is retained for in- spection.
LOSS INCURRED IN TRANSIT.

CHAPTER 2: INSTALLATION AND OPERATION
NEW SinBaD UNIT


2.1 Installation
DANGER All electrically operated appliances must be electrically grounded in accordance with local codes, or in the absence of local codes, with the applicable national electrical code. If this appliance is equipped with a three-prong grounding plug for your protection against electrical shock hazard, it must be plugged directly into a properly grounded three-prong receptacle. DO NOT CUT OFF OR REMOVE THE GROUNDING PRONG FROM THIS PLUG.
within the range 40° – 110°F (4° – 43°C).
Locate the unit in an area where it will not be bumped or jarred during normal activities. Movement of the unit during operation may cause inaccurate filling of the dispensing chute. 1. Position the cabinet assembly on a horizontal surface adjacent to an AC outlet of appropriate voltage (refer to the data plate affixed to the upper right corner of the right side of the unit). 2. Attach the receiver bracket to the desired side of the unit. Attach the basket rack arm to the rack on the side corresponding to the receiver bracket. Attach the basket rack assembly to the unit by inserting the arm into the receiver bracket. Place the basket rack crumb pan onto the base of the rack.
3. Assemble the hopper by inserting the drum into the hole at the rear of the hopper with the hole in the drum facing out. Position the lip of the deflector over the left edge of the hopper, and insert the sight glass into the V-shaped opening at the front of the hop- per. 4. Place the hopper on top of the cabinet with the sight glass to the front. Position the hopper so that the drum rotator is inserted into the hole in the drum, the hopper is sitting flat on the cabinet top, and its lower front edge is seated behind the locking rim of the cradle assembly (see illustration on Page 2-1). Place the lid onto the hopper, making sure the arrow on the lid points to the front of the unit. 5. Place the crumb pan onto the lower deck behind the two studs. Position the basket locator rack into the pan with the legs at the rear (see illustration on Page 2-1).

6. Make any final positioning adjustments necessary, then lock the casters and connect the unit to an appro- priate electrical source. If this equipment is wired directly into the electrical power supply, a means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fixed wiring. 7. Once the unit has been positioned, and connected, remove the load cell shipping protector. The load cell shipping protector consists of a bolt, red wingnut, shim, and large red tag. The bolt and shim MUST be removed for proper operation.

This bolt (with attached red wignut) and shim are used to protect the load cell during shipment. They must be removed before the unit will work properly.
2.2 Self-Zeroing The SinBaD unit is self-zeroing. Each time the unit is placed in the RUN mode, it performs a self-zeroing routine. The routine is characterized by the Dispensing Chute door opening for about 20 seconds and the se- quential flashing of the batch weight selector lights. The door will close and the lights will stop flashing when the self-zeroing routine is complete. 2.3 Operation

DANGER A pinch-point exists between the drum and hopper when the drum is turning. When removing or installing the deflector or dispensing chute, place the ON/OFF Rocker Switch in the “OFF” position. 6. Verify that the hopper is properly positioned in its cradle. Make sure that the hopper is seated behind the locking rim on the cradle. Failure to do so will result in malfunctioning of your unit. 7. Verify that the sight glass is installed. If it is not installed, fries will fall out of the hopper during opera- tion. 8. Place the ON/OFF Rocker Switch in the ON position. The switch will illuminate, indicating that electri- cal power is being supplied to the unit. 9. Press the RUN Switch once to place the unit in the RUN mode. The indicator light in the switch will illuminate. The dispensing chute door will open as the unit begins self-calibration and the lights in the batch weight selectors will sequentially flash. The door will close about 20 seconds later and the lights will stop flashing when calibration is completed. Only the RUN mode indicator will be illuminated. 10. Open the hopper lid and load up to 42 lbs/19 kg of French fries into the hopper. Close the hopper lid. 11. Press the BATCH WEIGHT Selector that corresponds to the desired weight of potatoes. The factory- programmed weights are 0.5 lb/.23 kg, 1.0 lb/.45 kg, and 1.5 lb/.68 kg (see illustration on Page 2-1).
The indicator light in the selector will illuminate and the drum will begin to rotate, transferring fries from the hopper to the dispensing chute. When the prescribed weight has been transferred, drum rotation will cease.
CAUTION The dispensing of fries into a basket is initiated by an inductive proximity switch located in the dispensing well. The proximity switch activates only when it senses a metallic mass greater than a certain size (e.g., an inserted basket). Thus, it will not be activated by the operator’s hand, a cleaning cloth, or any other non-metallic object. However, a ring, watch or some other type of metal could initiate a dispense cycle if inserted into the switch detection area.
NOTE: Built-in logic recognizes the removal and replacement of the basket. Once a dispense cycle has been completed, another basket may be inserted into the dispense well. As soon as the fries in the chute reach the specified weight, the unit will immediately dispense them into the waiting basket. The unit will NOT initiate another dispense cycle if the full basket is not removed and replaced, nor will it initiate another dispense cy- cle if there is no basket in the dispense well. To change the batch weight, press another of the numbered selectors before the chute is emptied. If the weight is increased, fries will be dispensed until the new weight is attained. If the batch weight is reduced, the change will take effect with the next cycle after the dispensing chute is emptied.

If the dispensing chute does not fill within 30 seconds, the CHECK HOPPER indicator in the middle of the control panel will begin to blink and drum rotation will stop. Check the hopper to see if it is empty. If it is empty, reload the hopper then press the PROGRAM Switch once to place the unit back into operation. If the hopper appears to contain plenty of fries, the fries have probably “bridged” (i.e., stuck together to form an arch over the drum). Redistribute the fries then press the PROGRAM
Switch once to place the unit back into operation. 2.4 Manual Operation If the unit fails to zero, the unit can be manually operated until a servicer arrives to make repairs. Follow the procedure below. 1. Turn the computer off (press the RUN Switch ). 2. Place a basket under the hopper dispense door. 3. Press the CLEAN Switch once to dispense fries into the basket. NOTE: If the dispense door fails to open, pull down on the door arm to manually open the door. 4. When the basket is filled to the desired level, press the CLEAN Switch once to stop dispensing fries.

3.1 Cleaning and Maintenance Routine cleaning in accordance with the following steps is the only operator maintenance required for your SinBaD unit. 1. Put the unit in STANDBY mode. Place a container beneath the dispensing chute and press the CLEAN Switch. The indicator in the switch will light. The dispensing chute door will open and the drum will rotate, transferring fries from the hopper to the container. Press the CLEAN Switch again to stop transferring. To transfer more fries, press the CLEAN Switch again. When the hopper is empty, press the RUN Switch once to return to the STANDBY mode. The dis- pensing chute door will remain open. 2. Place the ON/OFF Rocker Switch in the OFF position. 3. Remove the hopper lid and the metal deflector. Lift up on the hopper while carefully pulling it toward you. This will disengage the hopper from its retainer, allowing it to slide forward for removal. 4. Remove the dispensing chute by lifting it up from the load cell arms and carefully sliding it out toward you.

These components shown separated from cabinet to reveal load cell arms.
SERIOUS DAMAGE TO YOUR UNIT.
5. Clean the cabinet by brushing away crumbs with a basting brush, then wiping down all exposed surfaces with a soft cloth dampened with a solution of McDonald’s All Purpose Cleaner (HCS). 6. Clean the hopper and associated components by removing the hopper from the unit, disassembling the components, and washing all components with a solution of McDonald’s All Purpose Cleaner (HCS). Rinse with clean water and dry thoroughly. 7. Clean the dispense chute, basket locator rack, crumb pan, and basket rack by washing them with a solu- tion of McDonald’s All Purpose Cleaner (HCS). Rinse with clean water and dry thoroughly.
dispense chute, and basket rack may be cleaned with a water jet ONLY if removed from the unit.
Load Cell Arms · Dispense · Chute

the unit. 3.2 Operator Troubleshooting The operator troubleshooting guides that follow are intended to help operators resolve routine problems that may be encountered during operation of the unit.

PROBLEM Probable Causes Corrective Action B. If the erratic batch weights are
B. Verify that the dispensing chute is
occurring consistently, the probable cause is a misaligned component.
properly positioned on the load cell arms, that the deflector is properly positioned in the hopper, and that the hopper is fully seated behind the locking rim on the cradle assembly.
previous page.
If one of the above actions does not correct the problem, there may be a problem with the programmed weight settings or the load cell. Call FASC. A. Unit was not in STANDBY mode
A. The CLEAN mode can only be
when attempt was made to enter CLEAN mode.
selected when the unit is in the STANDBY mode.
UNIT WILL NOT GO INTO CLEAN MODE.
Press the RUN Switch once to place the unit in the STANDBY mode, and then press the CLEAN Switch.
If the above action did not correct the problem, call FASC.
Continued from
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| UNIT WILL NOT POWER UP or NOTHING HAPPENS WHEN “RUN” MODE IS SELECTED. | A. ON/OFF rocker switch is in OFF position. | A. Place rocker switch in the ON position. | p.12 |
| UNIT WILL NOT POWER UP or NOTHING HAPPENS WHEN “RUN” MODE IS SELECTED. | B. Unit is not plugged in. | B. Plug unit in. | p.12 |
| UNIT WILL NOT POWER UP or NOTHING HAPPENS WHEN “RUN” MODE IS SELECTED. | C. Main circuit breaker is tripped. | C. Reset circuit breaker. | p.12 |
| UNIT WILL NOT POWER UP or NOTHING HAPPENS WHEN “RUN” MODE IS SELECTED. | If the problem is not corrected by one of the above actions, call FASC. | p.12 | |
| RUN SWITCH INDICATOR AND PROGRAM SWITCH INDICATOR ARE FLASHING. | A. Dispensing chute is not properly positioned on the load cell arms. | A. Reposition dispensing chute so that is firmly seated on the load cell arms. Turn the unit OFF then back ON using the ON/OFF rocker switch. Press the RUN switch | p.12 |
| RUN SWITCH INDICATOR AND PROGRAM SWITCH INDICATOR ARE FLASHING. | Simultaneous flashing of the run switch indicator and program switch indicator signals that the unit is not properly zeroed. If the problem is not corrected by the above action, call FASC. | p.12 | |
| NOTHING HAPPENS WHEN A BATCH SIZE SELECTOR IS PRESSED. | A. Dispensing chute is full. | A. If the dispense chute has been loaded but not dispensed, nothing will happen until the batch has been dispensed, except when the batch weight is increased. Insert a basket into the dispensing well to dispense batch. | p.12 |
| NOTHING HAPPENS WHEN A BATCH SIZE SELECTOR IS PRESSED. | B. Unit is not in RUN mode. | B. Press RUN switch once. | p.12 |
| NOTHING HAPPENS WHEN A BATCH SIZE SELECTOR IS PRESSED. | If one of the above actions did not correct the problem, call FASC. | p.12 | |
| DISPENSE DOOR DOES NOT OPEN WHEN BASKET IS INSERTED. | A. The load cell may not have been satisfied within 30 seconds, normally because the hopper is empty or the fries have “bridged”. | A. Check the hopper to verify that the deflector is properly positioned. If there are fries in the hopper, verify that there is no bridging. If the hopper is empty, reload the hopper. Press the PROGRAM switch once to place the unit back into opera- tion. | p.12 |
| DISPENSE DOOR DOES NOT OPEN WHEN BASKET IS INSERTED. | If the above action did not correct the problem, call FASC. | p.12 | |
| ERRATIC BATCH WEIGHTS ARE BEING DISPENSED. | A. If the erratic batch weights are occurring only occasionally, the probable cause is bumping, jarring, and/or unusual vibration (such as caused by inserting a basket with undue force, the slamming of a freezer door, or the passing of a nearby train). | A. Exercise care when working around the unit to avoid bumping or jarring it while it is in operation. Ensuring that the unit is not touching adjacent walls, and placing the unit on a rubber mat will reduce the effect of environmental vibrations. | p.12 |
| Continued from previous page. | B. If the erratic batch weights are occurring consistently, the probable cause is a misaligned component. | B. Verify that the dispensing chute is properly positioned on the load cell arms, that the deflector is properly positioned in the hopper, and that the hopper is fully seated behind the locking rim on the cradle assembly. | p.13 |
| Continued from previous page. | If one of the above actions does not correct the problem, there may be a problem with the programmed weight settings or the load cell. Call FASC. | p.13 | |
| UNIT WILL NOT GO INTO CLEAN MODE. | A. Unit was not in STANDBY mode when attempt was made to enter CLEAN mode. | A. The CLEAN mode can only be selected when the unit is in the STANDBY mode. Press the RUN Switch once to place the unit in the STANDBY mode, and then press the CLEAN Switch. | p.13 |
| UNIT WILL NOT GO INTO CLEAN MODE. | If the above action did not correct the problem, call FASC. | p.13 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.