EN
Frymaster logo
Official user manual

Frymaster Series SR62

14 pages·410 KB·Fryer·PDF·ENDEFRITNLJA
Frymaster Series SR62
Table of Contents 32 sections Super Runner Series Gas Fryers Installation & Operation Manual · Series SR42, SR52 & SR62 · NON-CE & · For Service, Call (318) 865-1711 · … ShowHide
Page 1 of the Frymaster Series SR62 user manual — Price: $10.00
Page 1 · click to enlarge
Page 1
Frymaster Series SR62 — Super Runner Series Gas Fryers Installation & Operation Manual diagram (page 1)
Fig. 1 · Super Runner Series Gas Fryers Installation & Operat…

Super Runner Series Gas Fryers Installation & Operation Manual

Series SR42, SR52 & SR62

Frymaster Series SR62 — Series SR42, SR52 & SR62 diagram (page 1)
Fig. 2 · Series SR42, SR52 & SR62

NON-CE &

For Service, Call (318) 865-1711

Price: $10.00

Dean, 8700 Line Avenue, PO Box 51000,

MARCH 2008

PRINTED IN THE UNITED STATES

Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Avenue,

*8195999*

Shreveport, Louisiana 71106

Page 2 of the Frymaster Series SR62 user manual — Super Runner Series Gas Fryers Installation & Operation Manual
Page 2 · click to enlarge
Page 2

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

licensed plumber or pipe fitter.

Page 3 of the Frymaster Series SR62 user manual — Super Runner Series Gas Fryers Installation & Operation Manual
Page 3 · click to enlarge
Page 3

1.1 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual you will find notations enclosed in double-bordered boxes with the symbol . The information contained in the box concerns actions or conditions that may cause or result in injury to personnel or damage to your system, and/or cause your system to malfunction. 1.2 General Installation Instructions

type, including those of broilers and ranges.

concentrations of substances harmful to the health of personnel in the room where it is installed.

under a hood.

liquid. The means of restraint may be the manner of installation, such as connection to battery of

appliances or installing the fryer in an alcove, or by separate means, such as straps or chains.

cause injury. The appliance area must be free and clear of combustible material at all times.

NOTICE This appliance is only for professional use and shall be used by qualified personnel only. CLEARANCE AND VENTILATION This fryer must be installed with a 6-inch (150-mm) clearance at both sides and back when installed adjacent to combustible construction. No clearance is required when installed adjacent to non-combustible construction. A minimum of 24-inches (600-mm) clearance should be provided at the front of the fryer. The fryer flue opening must not be placed close to the intake of an exhaust fan, and the fryer must never have its flue extended in a "chimney" fashion. An extended flue will change the combustion characteristics of the fryer. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear must be kept clear and unobstructed. The fryer must be installed in an area with an adequate air supply and adequate ventilation. Adequate distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank. Filters should be installed at an angle of 45°. Place a drip tray beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96 states, "A minimum distance of 18-inches (450-mm) should be maintained between the flue outlet and the lower edge of the grease filter". Frymaster recommends that the minimum distance be 24-inches (600-mm) from the flue outlet to the bottom edge of the filter. INSTALLATION NOTE: Unless special ordered, this fryer is designed for operation at altitudes of 2000 feet (610 meters) and below. The unit must be modified for operation above 2000 feet (610 meters).

Page 4 of the Frymaster Series SR62 user manual — Super Runner Series Gas Fryers Installation & Operation Manual
Page 4 · click to enlarge
Page 4

For units equipped with legs: Lift the unit and move it into its final position. Do not drag or push the fryer into position. Doing so may damage the legs. Level the unit front to back and side to side. If the fryer is not level, the unit will not function efficiently. Super Runner Series gas fryers cannot be curb mounted and must be equipped with either legs or casters provided. A. Adjust leg height with an adjustable or 1-1/16-inch (27-mm) open-end wrench by turning the hexagon-shaped foot

on the bottom of the leg. NOTE: The foot is for minor leg height adjustment only. Do not adjust outward more than ¾-inch (19-mm). B. When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the

foot to the required height. For units equipped with casters: Roll the unit into its final position and lock the front casters. 1.3 Pre-Connection Preparation

required.

CE UNITS ONLY: Dean Super Runner gas fryers have obtained CE markings for countries and gas categories shown below:

CountriesSupply Pressures and Gas (mbar)Appliance Categories BE BelgiumG20 20/25 G31 37IIE(R)B3P DE GermanyG20 20 G31 50I2E I3P DK DenmarkG20 20I2H ES SpainG20 20 G31 37 and 50II2H3P FR FranceG20/G25 20/25 G31 37 and 50II2ESI3P GB Great BritainG20 20 G31 37II2H3P GR GreeceG20 20 G31 37 and 50II2H3P IR IrelandG20 20 G31 37II2H3P IT ItalyG20 20I2H LU LuxembourgG20/G25 20/25 G31 50II2E3P NL The NetherlandsG25 25 G31 50II2L3P PT PortugalG20 20 G31 37II2H3P
Frymaster Series SR62 — Super Runner Series Gas Fryers Installation & Operation Manual diagram (page 4)
Fig. 3 · Super Runner Series Gas Fryers Installation & Operat…

NON-CE UNITS ONLY: NATIONAL CODE REQUIREMENTS: This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration. This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect equipment stamped "NAT" only to natural gas and that stamped "PRO" only to LP (Propane) gas.

Page 5 of the Frymaster Series SR62 user manual — Super Runner Series Gas Fryers Installation & Operation Manual
Page 5 · click to enlarge
Page 5
ModelGas TypeOrifice SizeManifold Pressure KPaManifold Pressure Inches WC SR62Nat2.53 mm0.9 KPa3.6” SR62Prop1.6 mm2.4 KPa9.6”
MODEL*NOMINAL HEAT INPUTQn (kW)GAS TYPEORIFICE SIZE (MM)MANIFOLD GAS PRESSUREORIFICE QTY/ COLORBURNER MARKINGPILOT MARKING MBARINCH W.C. SR62 GM37.5G20 G25 G312.40 2.40 1.5112,0 17,5 22,04,8 7,0 8,85/BLUE 5/BLUE 5/REDBlue Blue Red26N 26N 16LP SR52 GM30G20 G25 G312.40 2.40 1.5112,0 17,5 22,04,8 7,0 8,84/BLUE 4/BLUE 4/REDBlue Blue Red26N 26N 16LP SR42 GM26G20 G25 G312.40 2.40 1.5112,0 17,5 22,04,8 7,0 8,83/BLUE 3/BLUE 3/REDBlue Blue Red26N 26N 16LP *SR prefixSuper Runner Series *GM suffixgas millivolt system with no electrical supply connections required
Frymaster Series SR62 — Super Runner Series Gas Fryers Installation & Operation Manual diagram (page 5)
Fig. 4 · Super Runner Series Gas Fryers Installation & Operat…
MODEL*NOMINAL HEAT INPUTQn (BTU)GAS TYPEORIFICE SIZE (MM)MANIFOLD GAS PRESSURE (INCH W.C.)ORIFICE QUANTITYPILOT MARKING SR62 GM150NAT LP2.53(#39) 1.51(#53)4 115 526N 16LP SR52 GM120NAT LP2.53(#39) 1.51(#53)4 114 426N 16LP SR42 GM105NAT LP2.80(#35) 1.70(#51)4 113 326N 16LP *SR prefixSuper Runner Series *GM suffixgas millivolt system with no electrical supply connections required
Frymaster Series SR62 — Super Runner Series Gas Fryers Installation & Operation Manual diagram (page 5)
Fig. 5 · Super Runner Series Gas Fryers Installation & Operat…

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating. 1.4 Connection to the Gas Supply Line NOTE: The gas supply (service) line must be the same size or greater than the fryer inlet line. This appliance is equipped with a ½-inch (15- mm) inlet. The gas supply line must be sized to accommodate all gas- fired equipment connected to the line. Consult the local gas company or supplier, or your local contractor for minimum supply line requirements. NOTE: If quick-disconnect supply lines or flex lines are used, increase supply line size to ¾-inch (22-mm) or larger.

Propane Applications; Proper Regulator Must Be Installed

Page 6 of the Frymaster Series SR62 user manual — NOT CONFIGURED!
Page 6 · click to enlarge
Page 6

a position where it can be reached quickly in the event of an emergency.

NOT CONFIGURED!

material. Foreign material in the burner and gas valve will cause improper and potentially dangerous

operation.

must be tested for leaks using a solution of soapy water before lighting any pilots. Never use matches, candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply to the appliance at the main shut-off valve and immediately contact the local gas company or an authorized

service agency for service.

Adequate means must be provided to limit the movement of fryers without depending upon the gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all times when the fryer is in use. NOTE: The installation must be inspected after it is complete to ensure it meets the intent of these instructions. The on-site supervisor and/or operator(s) should be informed that the appliance is installed with restraints. If restraints are removed to move fryer (cleaning beneath and behind, relocation, etc.), ensure that they are re-installed when fryer is returned to its permanently installed position. 1.5 Gas Conversion Procedures

Frymaster Series SR62 — NOT CONFIGURED! diagram (page 6)
Fig. 6

Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be performed by qualified,

licensed, and authorized installation or service personnel, as defined in Section 1.5 of this manual. CE UNITS ONLY: See gas valve illustration and gas valve, burner and orifice location when performing the following conversions. When converting from G20 to G25 gas, the following procedures apply:

♦ Equipment replacement is not required.

♦ Adjust orifice gas pressure to the appropriate value listed in the table on page 1-3 by turning the gas valve "adjustment screw".

♦ After adjustment, replace the adjustment-screw cover.

Page 7 of the Frymaster Series SR62 user manual — NOT CONFIGURED!
Page 7 · click to enlarge
Page 7

When converting from G20 (or G25) gas to G31 propane (or vice-versa), the following procedures apply:

♦ Burner orifices and pilot orifice MUST be replaced.

♦ Adjust orifice gas pressure to the appropriate value listed in the table on page 1-3 by turning the gas-valve adjustment screw.

♦ After adjustment, replace the adjustment-screw cover.

♦ Affix the new label included with the conversion kit next the existing rating plate stating that the gas type has been converted. Remove any references to the previously used gas from the existing rating plate. When converting from G20 (20 mbar) to G25 (25 mbar), or vice-versa, or G31 (37 mbar) to G31 (50 mbar), the following procedures apply:

♦ Check pilot-adjustment and adjust as necessary. ♦ Other adjustments are not necessary. Conversion from one gas family to another (i.e. changing from natural gas to propane) requires special components. Obtain the necessary components using the cross-reference in Section 1.6, Gas Conversion Components. Conversions can only be executed by qualified, factory-authorized personnel. NON-CE UNITS ONLY: See gas valve illustration below and gas valve, burner and orifice location on page 1-6 when performing the following conversions. When converting from natural gas to propane (or vice-versa), the following procedures apply:

♦ Burner orifices and pilot orifice MUST be replaced (see page 1-6 for required component part numbers).

♦ Adjust orifice gas pressure by turning the gas-valve adjustment screw (see page 1-3 for gas types and pressures).

♦ After adjustment, replace the adjustment-screw cover.

♦ Affix the new label included with the conversion kit next the existing rating plate stating that the gas type has been converted. Remove any references to the previously used gas from the existing rating plate. Conversion from one gas family to another (i.e. changing from natural gas to propane) requires special components. Obtain the necessary components using the table on page 1-6. Conversions can only be executed by qualified, factory-authorized personnel.

Vent tube connection ON/PILOT/OFF

Frymaster Series SR62 — NOT CONFIGURED! diagram (page 7)
Fig. 7
Frymaster Series SR62 — NOT CONFIGURED! diagram (page 7)
Fig. 8

ON Button (pilot gas flow)

Typical Non-CE Gas Valve

Typical CE Gas Valve

Show 9 more labels / short text on this page
Pressure Flow · Knob · Adjustment · OFF Button · Vent Tube Connection · Thermocouple · Connection · Pilot Flow Adjustment · Pressure Tap
Page 8 of the Frymaster Series SR62 user manual — NOT CONFIGURED!
Page 8 · click to enlarge
Page 8
Frymaster Series SR62 — NOT CONFIGURED! diagram (page 8)
Fig. 9

Typical gas valve, burner and orifice locations (SR42 shown above).

.6 Gas Conversion Components se the following components to convert from natural gas to propane and viceersa. See Section 1.5 for orifice quantities required for conversion.Propane Applications: Proper Regulator Must Be Installed Natural Gas to Propane Kit. 826-1817Propane To Natural Gas Kit, 826-2017 Bushing, NPT Flush, SR 42 series onlyBushing, NPT Flush, SR 42 series only Pilot Orifice (16LP) CE & Non-CEPilot Orifice (26N) CE & Non-CE Burner Orifice, 1.51mmCE ONLY: All Super Runner SeriesBurner Orifice, 2.40mmCE ONLY: All Super Runner Series Burner Orifice, 1.51mm (#53)- NON-CE ONLY: SR5 & SR62 Series Only2 Burner Orifice, 2.53mm (#39)- NON-CE ONLY: SR52 & SR62 Series Only Burner Orifice, 1.70mm (#51)- NON-CE ONLY: SR4 Series Only2 Burner Orifice, 2.80mm (#35)- NON-CE ONLY: S42 Series Only Rating label, contact factory at time of conversionRating label, contact factory at time of conversion * Burner orifices listed above are for fryers operating at altitudes of 2000 feet (610 meters) or less. For altitudes greater than 2000 feet (610 meters), contact the factory for the correct orifice size.
Page 9 of the Frymaster Series SR62 user manual — PILOT
Page 9 · click to enlarge
Page 9

2.1 Initial Startup Wash the unit and accessories thoroughly with hot, soapy water to remove any film residue, dust or debris. Rinse and wipe dry. Close the drain valve completely. Ensure the operating thermostat and high-limit thermostat sensing bulbs inside the frypot are securely seated in the holding clamp. 2.1.1 Operating the Gas Valve NON-CE UNITS ONLY: Rotate the knob counter-clockwise to the ON or PILOT positions. Depress and rotate the knob clockwise to turn the valve OFF.

PILOT

PILOT

OFF

OFF

ON

ON

PILOT Position ON Position

CE UNITS ONLY: Depress white button to light pilot and turn gas valve on. Depress red button to turn the valve off.

2.1.2 Pilot Lighting Procedures NOTE: This fryer was tested, adjusted and calibrated to sea level conditions before leaving the factory. Adjustments may be necessary to meet local conditions, and are to be performed only by qualified service personnel. Adjustments are the responsibilities of the customer or dealer and are not covered by Dean warranty. The pilot is located high in the cabinet center, at the base of the frypot. Use a long match or taper to light the pilot. Perform the following steps in sequence before lighting the pilot: NON-CE UNITS ONLY: 1. Turn off the manual shut-off valve on the incoming gas supply line.

Frymaster Series SR62 — PILOT diagram (page 9)
Fig. 10
2. Turn the operating thermostat to the OFF position.
3. Depress and turn the gas valve knob to the OFF position.
4. Wait at least 5 minutes for any accumulated gas to disperse.

Pilot/On Button · Off Button

Page 10 of the Frymaster Series SR62 user manual — PILOT
Page 10 · click to enlarge
Page 10
5. Fill the frypot with oil, shortening or water to the bottom OIL LEVEL line scribed on the frypot back. Ensure heating tubes are covered in liquid prior to engaging burners.
7. Push and hold the knob in and apply a lighted match or taper to the pilot burner head. Continue to hold the knob in for about 60 seconds after the flame appears on the pilot. Release the knob. The pilot should remain lit.

CE UNITS ONLY: 1. Ensure that the following steps are done in sequence before lighting or re-lighting the pilot: 2. Turn off the manual shut-off valve on the incoming service line. 3. Turn the operating thermostat "OFF". 4. Depress the red button on the safety control valve to turn "OFF". 5. Wait at least 5 minutes for any accumulated gas to disperse. 6. Fill the frypot with oil, shortening or water to the bottom OIL LEVEL line scribed on the frypot back. Ensure heating tubes are covered in liquid prior to engaging burners.

NOTE: If solid shortening is used, pack the shortening into the frypot, ensuring the shortening is packed beneath, between and above the tubes prior to operating fryer. 7. Open the manual shut-off valve on the incoming service line. 8. Apply a lighted match or taper to the pilot burner head. (If fryer is equipped with a piezo ignitor, go to Step 9). 9. Press the white button on the gas valve and hold approximately 45 seconds to 1 minute, until the pilot stays lit. (If fryer is equipped with a piezo ignitor, press and hold the white button, then repeatedly press the piezo ignitor button until the pilot lights. Release the white button after approximately 45 seconds to 1 minute.) 10. If the pilot does not stay lit, depress the white button and re-light the pilot, holding the button in longer before releasing. Trapped air may necessitate re-lighting the pilot several times until a constant gas flow is attained. 11. When the pilot stays lit, release the white button. 2.1.3 Lighting the Burners

heating tubes and frypot, and void the warranty. 1. Ensure the frypot is filled with oil or shortening to the lower of the two oil level lines embossed on the back wall of the frypot. NOTE: If solid shortening is used, pack the shortening into the frypot, ensuring the shortening is packed beneath, between and above the tubes prior to operating fryer.

Page 11 of the Frymaster Series SR62 user manual — PILOT
Page 11 · click to enlarge
Page 11

cooking oil or water covers the burner tubes before lighting the burners.

2. With the pilot lit, push down and slowly turn the gas valve knob to the ON position. 3. Rotate the operating thermostat knob to the desired frying temperature. The burner should light and burn with a strong blue flame.

lighting.

2.2 Shutting the Fryer Down For temporary shutdown, turn the operating thermostat to the OFF position and cover the frypot. For complete shutdown, turn the operating thermostat to the OFF position, turn the gas valve knob to the OFF position (Non-CE) or press the red button (CE) and cover the frypot. 2.3 Daily Operation 1. Do not allow grease to accumulate or harden on the frame, body, or flue of the fryer. Clean the fryer inside and out with a solution of detergent and hot water daily. 2. Filter the cooking oil by draining the frypot through a filter cone at least daily. After the oil has been drained from the frypot, remove any residue from the pot, using a scraper if necessary. 3. Clean the frypot at least once each week by filling it to just below the upper oil level mark with water. Add one cup of detergent and bring the solution to a boil. Allow the solution to simmer for 10-15 minutes, then drain and rinse the frypot with clean water twice. Add ¼ cup of white vinegar to the last rinse to neutralize any alkalinity remaining from the detergent. Wipe the frypot surfaces with a dry towel before refilling with cooking oil. If the fryer is not to be used immediately after cleaning, it is suggested that the inside of the frypot be wiped down with a light coat of cooking oil to prevent rust. 2.4 Recommended Spare Parts

DESCRIPTIONPART # SR42NONCEPART # SR42CEPART # SR52/SR62NON-CEPART # SR52/SR62CE Operating Thermostat807-3515807-1692807-3515807-1692 High-Limit Thermostat807-3516807-3560807-3680807-3560 Thermopile810-2033807-3565810-2033807-3565 ThermocoupleN/A812-1284N/A812-1284 Pilot Burner, Natural Gas810-2032810-2032810-2032810-2032 Pilot Burner, Propane Gas810-2155810-2155810-2155810-2155 Pilot Bracket, AGAN/A200-6564N/A200-6564 Pilot Thermopile BracketN/A810-2401N/A810-2401 Piezo Ignitor TriggerN/A810-1001N/A810-1001 Piezo Ignitor BracketN/A200-1868N/A200-1868 Piezo Ignitor ElectrodeN/A807-3540N/A807-3540 Orifice, Natural810-2040810-2060810-2048810-2060 Orifice, Natural, units built after 4/07810-3097810-3101N/AN/A Orifice, Propane810-2064810-2059810-2059810-2059 Orifice, Propane, units built after 4/07810-3099810-3102N/AN/A Gas Valve, Natural807-1603807-2122807-1603807-2122 Gas Valve, Propane807-1604807-2121807-1604807-2121 Leg810-2053810-2053810-2053810-2053 Caster, 5-inch w/o Brake810-0356810-0356810-0356810-0356 Caster, 5-inch w/Brake810-0357810-0357810-0357810-0357
Page 12 of the Frymaster Series SR62 user manual — OFF
Page 12 · click to enlarge
Page 12

2.5 Wiring Diagram CE UNITS ONLY:

PP TH

PP TH

THERMOPILE HONEYWELL 807-3565

OPERATING THERMOSTAT

COAXIAL LEAD TO THERMOCOUPLE 812-1284

HIGH-LIMIT

HONEYWELL CE

NON-CE UNITS ONLY:

CONTROL CIRCUIT

PILOT GENERATOR

PILOT ADJ.

1/2 P.S.I.

HONEYWELL

HONEYWELL 1/2 P.S.I.

PILOT

ON

HONEYWELL

1/2 P.S.I.

OFF

HIGH-LIMIT

N/O COM N/C

OPERATING THERMOSTAT

Page 13 of the Frymaster Series SR62 user manual — THIS PAGE INTENTIONALLY LEFT BLANK
Page 13 · click to enlarge
Page 13

THIS PAGE INTENTIONALLY LEFT BLANK

Page 14 of the Frymaster Series SR62 user manual — 819-5999 MARCH 08
Page 14 · click to enlarge
Page 14
Frymaster Series SR62 — Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000 diagram (page 14)
Fig. 11 · Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Lo…

Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000

Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135

Price$10.00 PRINTED IN THE UNITED STATES

819-5999 MARCH 08

Ask about the Frymaster Series SR62

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster Series SR62

Be the first to ask — other owners or our team will answer.

Original document

Frymaster Series SR62 manual PDF

14 pages·410 KB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…