Frymaster, a member of the Commercial Food Equipment Service Association, recommends hiring technicians who are certified by CFESA.

NOTE This device is intended for commercial use only and must be operated by qualified personnel. Installation, maintenance and repairs must be carried out by a service centre (FASC) authorised by the Frymaster/DEAN plant or another qualified technician. Installation, maintenance or repairs by non-qualified personnel can nullify the manufacturer's warranty. Chapter 1 of this manual contains the definitions for qualified personnel.
NOTE This device must be installed in accordance with the relevant country and local regulations of each installation country. For details, see the REQUIREMENT for AUTHORITY RULES in Chapter 2 of this manual.
NOTES FOR CUSTOMERS IN THE U.S.A. This device must be installed in a way that complies with the basic installation rules of Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
NOTE Drawings and photographs in this manual illustrate operational, cleaning and technical procedures and do not necessarily correspond to the operating practices of local kitchen management.
USA This device complies with Part 15 of the FCC regulations. Operation shall be subject to the following two conditions: 1 This equipment must not cause any interference and 2 this equipment must be capable of receiving noise signals which could cause undesirable operation. This device is classified as Class A, but it meets the limits of class B devices.
This digital device does not exceed the limits of Class A or B for radio emissions set by standard ICES-003 from the Canadian Department of Communications.

During the operation, installation and maintenance of this product, personnel may be exposed to glass wool particles or ceramic fibres, crystalline silicon and/or carbon monoxide released into the air. Inhalation of glass wool particles or ceramic fibers released into the air is classified as carcinogenic in the US state of California. Carbon monoxide inhalation is classified as a cause of birth defects or other damage to the human reproductive system in California.

LIST OF CONTENTS
1.1 Spare parts order and service information 1-1 1.2 Safety information 1-1 1.3 Specific information for the European Community (CE) 1-2 1.4 Equipment description 1-3 1.5 Installation, operation and maintenance personnel 1-3 1.6 Definitions 1-3 1.7 Claims of damage in case of transport damage 1-4 CHAPTER 2: Installation instructions
2.1 General installation requirements 2-1 2.2 Installation of rollers/standing legs 2-3 2.3 Preparations for connection 2-3 2.4 Connection to gas pipeline 2-4 2.5 Changeover to another type of gas 2-7 CHAPTER 3: Operational instructions
3.1 Start-up method 3-2 3.2 Cooking of the frying trough 3-3 3.3 Switch off of the Frying Machine 3-5 3.4 Controller operation and programming 3-5 CHAPTER 4: Filtration instruction
4.1 Discharging and manual filtering 4-1 4.2 Operation of the built-in filtration system 4-2 Preparation of the filter unit for use 4-2 operation of the filtration unit 4-4 Replacement of the Filter Paper 4-6 CHAPTER 5: Preventive maintenance
5.1 Preventive maintenance tests and service of the frying machine 5-1 Daily inspections and service 5-1 Weekly inspections & service 51 Monthly inspection and service 3 Viet Nam examinations & Service 5-4 Semi-Annual inspections And service 5-7 5.2 Preventative maintenance testing & service of built-in filter system 5-8 5.3 Annual/Regular System inspection 5-9 CHAPTER 6: Defect-finding by operators
6.1 Introduction 6-1 6.2 Defect search on frying machines with Computer Magic III, basket lifter timer or digital controller 6-2 6.3 Defect finding on fries machines having analogue controller (solid state) 6-4 6.4 Defect find on the built-in filter system 6-6 6.5 Defect check on the basket jack 6-6.6 Replacement of ignition module safety device 6-7 6.7 Replacements of the controller or control cable tree 6-8

1.1 Application and validity
The (insert equipment family) model family has been approved for sale and installation by the European Community in the following Member States: AT, BE, DE, DK, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE.
This user manual applies to all (insert equipment family) machines sold in English-speaking countries, including those in the European Community. If there are differences between the instructions and information in this guide and local or state regulations in the country where this device is installed, installation and operation must comply with relevant national and local regulations.
This equipment is intended for commercial use only and must be operated by qualified personnel (see definition in Chapter 1.7).
1.2 Spare parts order and service information
In order for us to help you as quickly as possible, the Frymaster FASC (Factory Authorized Service Center) or maintenance department manager needs certain information about the device. Most of this information can be found on the nameplate at the inside of the frying machine door. Part numbers are to be found in the installation, use and maintenance instructions and parts manual. Parts orders can be placed directly at the local FASC or with the local distribution company. When delivered ex works, the frying machine is accompanied by a list of Frymaster FASCs. If you do not have this list, call 1-800-551-8633 (USA/CANADA) to Frymaster’s technical maintenance department.
When ordering parts, the following information is required:
Service information may be obtained from the local FASC or the local distribution company. Service can also be obtained by telephone from Frymaster’s technical maintenance department at 1-800-551-8633 (USA/Canada) or +1-318-865-1711 (worldwide). When requesting maintenance, please provide the following information:
In addition to the model number, serial number and gas type, it is also necessary to describe the nature of the problem and provide related information that could help solve the issue.

REPEAL THIS MANUAL AND USE IT FOR FUTURE PURPOSES IN A
KEEP A SAFE PLACE.
1.3 Safety information
Before attempting to operate the device, read through well the instructions in this manual. This manual contains instructions in double-edged boxes (as shown below).
be able to guide the apparatus.

lead and may result in malfunctions of the equipment.
The frying machine is equipped with automatic safety functions:
1.4 Specific information for the European Community (CE)
The European Community (CE) has established certain standards for this type of equipment. If there are differences between a CE standard and an outside of the CE, the relevant information or instructions will be displayed by shaded text fields as shown below.


1.5 Device description
The H50 series high efficiency gas fryers use a unique infrared burner system that requires up to 43% less energy for the same volume than a conventional frying machine. The models in this series include the MJH50, FMH50 and FPH50 versions. MJH50 variants do not have a built-in filtering system. FMH50 variants have a built-in filter Magic II filtration system. The Filter Magic system is housed in its own cabinet, which can be attached to both sides of a frying machine and placed anywhere on a bank of fryers. The FPH50 variant has a built-in FootPrint III filtration system that is housed under the frying machine to save installation space. (In frying machine benches, the FootPrint III system is always located under the two fryers on the far left.) All H50 series of fry machines are open-tube models without tubes and have a hand sized opening to the deep cold zone that speeds up and facilitates cleaning of the stainless steel fry trough.
The heating is effected by two infrared burner assemblies, each of which is fastened to one side of the frying tray. The combustion air for the burners is supplied by a separate fan which is mounted at the front on the frying trough. H50 series frying machines can be made for natural gas, propane (liquefied petroleum gas) or city gas; this may be requested by the customer.
Each frying trough is equipped with a temperature probe for exact temperature control.
All H50 series frying machines come standard with electronic ignition, melting cycle and boil mode. The user options include Computer Magic III computer, analog controller (solid state), digital controller and basket lifter timer.
All frying machines in this series require an external AC power supply. The machines can be configured for voltages between 120 V~ and 220 V~.
Frying machines equipped with built-in FootPrint III filtration systems are delivered in a fully assembled manner. In the case of frying machines without FootPrint III, legs or optionally rollers must be mounted at the installation site. All frying machines come with a set of standard accessories. Each frying machine is set, tested and inspected at the factory before packaging.
1.6 Installation, operation and maintenance personnel
Operational information for Frymaster devices has been prepared only for use by qualified and/or authorized personnel, as defined in Chapter 1.6. All installation and maintenance work on Frymaster equipment must be performed by qualified, certified and/or authorized installation and service personnel as defined in Chapter 1.6.
1.7 Definitions
QUALIFIED AND/OR AUTHORISED PERSONNEL Qualified/authorised operations personnel are those who have carefully read the information in this manual and familiarized themselves with equipment functions or already had experience of operating the equipment described in this Manual.

Qualified installation personnel are persons, companies, enterprises or companies who either personally or through representation engage in and are responsible for the installation of gas-fired equipment. Qualified personnel shall have experience of such work, be aware of all applicable gas precautions and comply with all requirements in force.
Qualified maintenance personnel are those who are familiar with Frymaster equipment and have been certified by FryMaster L.L.C. have been authorised to carry out maintenance work on his equipment. All authorised maintenance personnel must be equipped with a complete set of service and parts manuals, as well as keep in stock the minimum number of spare parts for Frymster equipment. A list of Frymaster FASCs (Factory Authorized Service Centers) is included in the frying machine. If not qualified If the maintenance personnel are used, this will nullify Frymaster’s warranty.
1.8 Claims for damage in the event of transport damage
The Frymaster dressing machine was carefully checked and packaged before delivery from the factory. The carrier assumes all responsibility for secure delivery as soon as he has taken over the device to the transport.
Measures to be taken if the equipment is damaged:
Frymaster DOES NOT ASSUME RESPONSIBILITY FOR DAMAGES OR LOSSES,
WHO WERE ON THE TRANSPORT ROUTE.

2.1 General installation requirements
All installation and maintenance work on Frymaster equipment must be performed by qualified, certified and/or authorized installation and service personnel (as defined in Chapter 1.7 of this Manual).
The conversion of this equipment from one type of gas to another must be carried out by qualified, certified and/or authorised installation and maintenance personnel (as defined in Chapter 1.7 of this manual).
If no qualified, certified and/or authorised installation and maintenance personnel are used for the purpose of installing or switching to another type of gas or other maintenance (as defined in Chapter 1.7 of this manual), this will nullify Frymaster’s warranty; damage to equipment and injury to staff may also occur.
If there are differences between the instructions and information in this guide and local or state regulations in the country where this device is installed, installation and operation must comply with relevant national and local regulations.

After delivery, the cooker must be carefully checked for visible or concealed damage. (See recitals) Claims for damage in the event of transport in Chapter 1.

The frying machine or the chuck, i.e. The frying machines shall be so placed that there is 150 mm (6 in) clearance on both sides and rear if the adjacent walls/devices are combustible; no clearance is required when positioned next to non-combustable walls. At least a clearance of 600 mm (24 in) shall be left on the front side of the frying machine.


One of the most important considerations for economical use of the frying machine is ventilation. It shall be ensured that the frying machine is set up in such a way as to remove combustion gases efficiently and so that the kitchen ventilation system does not produce air drafts which impair burner function.
The exhaust opening of the frying machine shall not be located near to the entrance for the blower and the exhaust openings of the frozen-frying engine shall not extend ‘chimney shape’. An extended exhaust gas opening changes the combustion properties of the frying machine and leads to a longer recovery time. It also often causes a delayed ignition. In order to provide the air flow required for good combustion and burner operation, the regions on the front side, rear side and both sides of the frying machine must be unadjusted and free from blockages.
The frying machines must be placed in an area with sufficient air supply and ventilation. A sufficient distance must be maintained between the exhaust opening of the frying machine and the lower edge of the vent filter bank. The filters must be installed at an angle of 45o. A drip plate shall be installed below the lower edge of the filter. For listings in the U.S. The NFPA standard No. 96, which states that ‘a minimum clearance of 450 mm (18 in.) shall be observed between the exhaust opening and the lower edge of the grease filter’; Frymaster recommends for devices with more than 120,000 BTU/h. provide a minimum distance of 600 mm (24 in) between the exhaust opening and the lower edge of the filter..
For installations in the U.S.A. information on the design and assembly of venting hoods can be found in the above-mentioned NFPA standard. A copy of the standard can be obtained at: National Fire Protection Association, Battery March Park, Quincy, MA 02269, U.S.A.
The type of gas for which the frying machine is intended is indicated on the nameplate at the inside of the frieser door. Connect a frying machine with the indication ‘NAT’ to natural gas only; ‘PRO’ is suitable for propane gas only and ‘MFG’ is appropriate for urban gas only.
The installation shall be carried out with a gas connection that meets national and local regulations, as well as CE requirements where applicable. Quick-release fasteners, if used, shall also comply with national and local regulations and CE requirements where applicable.
All electrically operated equipment shall be grounded in accordance with all applicable national and local regulations, as well as CE requirements if any. A circuit diagram is located on the inside of the frying machine door. The prescribed stresses are indicated on the nameplate at the inside of the frying machine door.

The User is warned that any changes to Frymaster computers not expressly approved by the party responsible for conformity may nullify the user’s authorization to operate this device.
Frymaster computers have been tested and therefore meet the limits for a Class A digital device according to Part 15 of the FCC regulations. These devices are classified as Class A, but they meet the limits of class B devices. If the device is operated in a commercial environment, these limits are intended to provide acceptable protection against interference. This device generates and uses high-frequency energy, which can also emit it; if not installed and used as specified in the instructions manual, radio/TV reception may be disturbed. The operation of the device in a residential area is likely to cause disruptions; in this case, the user is obliged to correct these disruptions at his own expense.
The user can find the following brochure helpful: “How to identify and resolve radio-TV interference problems”. This brochure is prepared by the US Federal Communications Commission and can be obtained at: U.S. Government Printing Office, Washington, DC 20402, U.S.A., Stock No 004-000-00345-4. If necessary, the user should consult with the dealer or an experienced radio and TV technician.
2.2 Installation of castors/standing legs
Depending on the configuration ordered, the frying machine may have been delivered without installed rollers or legs. THIS DEVICE IS NOT SET UP WITHOUT RUNNING ROLLERS OR LEGS. If the frying machine requires installation of rollers or legs, these shall be installed in accordance with the instructions contained in the accessories package.
2.3 Preparations for connection


a. Connect the power cable(s) of the frying machine to a socket.
b. The power switch on EIN switched.
c. The power switch of the frying machine is mounted on AUS switched. Check that the mains and heating lamps are turned off or the indicator is empty.



2.4 Connection to the gas line
Never use matches, candles or other sources of ignition to check for leakage. If gas smell is detected, switch off the supply of gas to the device at the main valve and immediately notify the local gas plant or an authorized service point for service.
The diameter of the gas line used is extremely important. If the diameter is too small, the gas pressure at the burner distributor is low. This can lead to slow recovery and delayed ignition. The gas supply line should have a minimum diameter of 38 mm (11⁄2 in.). The table on the following page shows minimum sizes for interconnectors.


Erdgas 3/4" (22 mm) 1" (28 mm) 1 1/4" (36 mm)
Propane 1/2" (15 mm) 3/4" (22 mm) 1" (28 mm)
City gas 1" (28 mm) 1 1/4" (36 mm) 2 1/2" (41 mm)
* For distances of more than 6 m (20 ft) and/or for more than 4 screw connections or elbows, the next larger tube diameter shall be used.
The H50 series has been awarded the CE marking for countries and gases listed in the following table. NOTE: The nominal heat input power (QN) is 21 kW except for AT, DE, LU and category 3P/B which is 23 kW.
COUNTRIES CATEGORIES GAS PRESSURE (MBAR) G20 20 ÖSTERREICH (AT) II2H3B/P G30, G31 50 I2E(R)B G20, G25 20, 25 BELGIEN (BE) I3+ G30; G31 28-30; 37 G20-20 DANMARK (DK); II2 H3B / P G30: G31 30 G20; G25 20.
II2ESI3P G31 50 G20 20 FINLAND (FI) II2H3B/P G30, G31 30 G20, G25 20 II2ELL3B /P G40, G 31 50 GERMANY
I3P G31 50 G20 20 GREECE (GR) II2H3+ G30, G31 28-30, 37 G20 20. ITALIEN (IT) II1H3 + G30 , G 31 28- 30, 37 G20 20 IRELAND (IE) II 2H3 > G30 G31 28.00 - 30 G31.200 LUXEMBOURG (LU), II2E 3B/P G30
II2L3B/P G30, G31 30 NORWAY (NO) I3B / P G30 , G 31 30 G20 20 PORTUGAL (PT) II2H3+ G30 G31 28-30, 37 G20 21 + 2 H3+G30, G31 28 - 30, 37 G20 20 SPAIN (ES)
II2H3P G31 37, 50 G20 20 SWEDEN (SE) II2H3B/P G30, G31 30 G20 20 UK (UK) II1H3+ G30 , G 31 28-30
CE standard The prescribed air supply quantity for the combustion air supply is 2m3/h per kW.
CE gas categories, by country

NOTE: Some frying machines are designed for a rigid connection to the gas supply line. These devices are connected to the gas supply line on the device rear side.
The thread sealing compound may be applied only in very small quantities and only to external threads. Use a pipe sealant which is not impaired by the chemical action of liquid gases (e.g. LoctiteTM PST56765 sealant. Do not apply any sealing means to the first two thread turns. This could lead to sealing means entering the gas stream and clogging the burner openings and/or the control valve.


CE standard burner distributors, gas pressure values for frying machines manufactured after April 1999
CE standard burner distributors, gas pressure values for frying machines manufactured until April 1999
Two furnaces Natural gas Lacq (G20) below 20 mbar 7 7
Two furnaces Natural gas Lacq (G20) below 20 mbar 7 6.5
Natural gas Gronique * (G25) less than 25 mbar 10
Natural gas Gronigue * (G25) less than 25 mbar 10 9
Butane/propane (G30) at 28/30 or 50 mbar 17 17
Butane (G30) at 28/30 or 50 mbar 17 16.5
Propane (G31) below 37 or 50 mbar 20 20
Propane (G31) below 37 or 50 mbar 20.2 18.5
* Belgium G25 = 7.0 mbar (one or two)
* Belgium G25 = 7.0 mbar (one) or 6.5 (tweil)


2.5 Conversion to another type of gas
If you switch to a different type of gas without installing the correct conversion components, there may be fire or explosion. THIS DEVICE MUST NOT BE CONNECTED TO A GAS SUPPLY FOR WHICH IT IS NOT INTENDED!
The conversion of this equipment from one type of gas to another must be carried out by qualified, certified and authorised installation and maintenance personnel (as defined in Chapter 1.7 of this manual).
The H50 series frying machines, which are manufactured for non-CE countries, use a different burner for each type of gas. The burners in propane gas frying machines have a special grey coating of the burner tiles, which are able to cope with the higher energy content of propanes. Propane gas burners may be used for natural gas supplies, but not vice versa.

Gas conversion rates for non-CE versions Natural gas to propane gas (LP) Propane gas (LC) to natural gas Undivided furnace: Part No 826-1145 Undivoted furenum: Part Number 826-1046 Double furnishing: Part number 826-1147 Double furencing: Part no 826-148
Machinery intended for export to CE countries is equipped with universal burners that can run on natural gas (G20, G25) or butane gas (g30) and propane gas (ga31).

CE gas conversion kits for versions with a gas valve 810-1011 G20 or G25 (gas) to G30 or G31 Gas: G30, or G32 to G20, or gas: Parts 826-1196




CHAPTER 3: OPERATIONAL INSTRUCTIONS

Control panel (CM III computer shown)
drainage and filter control handles.
TYPICAL EXECUTION (SHOWN FPH250) NOTE: The appearance of the frying machine can vary slightly depending on the design and production date.

3.1 Procedure for placing in service
Before the frying machine is started, ensure that the fries are switched off and that the trough outlet valve(s) are closed. Remove the basket support shelves, if any, and fill up the frying tub to the lower oil level line.
If solid fat is used, make sure it’s packed into the frying tub at the bottom.

After the ON/OFF switch has been set to OFF, set the gas valve button TO OUT, wait for 5 minutes and then set the button to ON.
Ignition of the frying machine


is behind the engine
The optimal flame color is a bright orange-red. If a blue flame is observed or dark spots are visible on the burner surface, the air/gas mixture must be re-regulated. The procedures for this differ for CE and non-CE devices.
On the side of the fan housing opposite to the motor is a plate with one or two securing nuts. Remove the nut(s) sufficiently to allow for displacement of the plate. The plate now enlarges or closes the air intake opening for so long. Reduce the size until the flame is bright orange-red. Carefully hold the plate in this position and tighten the securing nut(s).
Right viewing opening · Left viewing opening


CE devices manufactured before May 1999 are equipped with a protective assembly in front of the blowers. An air closing flap on the end face of the protective assembly regulates the supply of air to the fan inlet. To adjust the closing flap, release the securing screws and move the flap to the right or left until a bright orange-red flame is obtained. Carefully hold the closing flap in this position and tighten the securing screws.
3.2 Boiling of the frying tub
In order to ensure that the frying tray does not contain any impurities which may have been introduced during manufacture, transport or installation, it is necessary to boil the fries before first use. Frymaster recommends cooking the fry tub every time you change fat.
In the case of frying machines, which are equipped with a Digital controller are equipped with setpoint-value up/down arrow keys to adjust the setpoint value at 91°C (195°F).
In the case of frying machines, which are equipped with a Basket lifter timer equipped with the boil-out mode key
Press to reset the timer to 195°F (91°C).
In the case of frying machines with a Computer Magic III Computers shall:




3.3 Switching off the frying machine
In the event of a short-term shutdown during the working day, the controller ON/OFF switch is activated AUS place the lids and put them on (if equipped with a frying machine).
When the frying machine is switched off after work, open the ON/OFF switch of the controller AUS pose.

After the ON/OFF switch has been set to OFF, set the gas valve button to OUT.
Place the lids on the frying tray (if equipped with a machine).
3.4 Controller operation and programming
H50 series frying machines may be equipped with any of the following control systems:
Operating instructions for the present controller are given in our own Controller Instructions for Frymaster Friction Machines.

CHAPTER 4: FILTERING INSTRUCTION

DANGER The discharge and filtering of fry fat or oil must be carried out carefully to prevent the possible serious burns if handled imprudently. The oil to be filtered has a temperature of about 177° C. (350° F). Ensure that all hoses are properly connected and drain faucets in the correct position before operating switches or valves. Appropriate protective equipment is used when frying fat or oil is drained and filtered.
If the frying machine is not equipped with a built-in filter system (FootPrint III or Filter Magic II), the fat or oil must be drained into another suitable container. (For safe and practical drainage and disposal of used fat or oil, Frymaster recommends) The use of Frymaster Fat disposal unit (FEE). The FEE is available from your local distribution company.


DO NOT use the cleaning rod to hammer on the drain valve or other objects. Damage to the valve ball will cause leaks and nullify Frymaster guarantee.

4.2 Operation of the built-in filtering system
Both the FootPrint III (FP III) and Filter Magic II (FM II) filtering systems allow for safe and efficient filtration of oil or grease in a frying pan while keeping the other fry pans at one station operational. The FootPrint III and Filter Magic II systems have different designs and looks, but they are operated in the same way. The operation of the system FootPrint III is shown in this paper, but the steps apply equally to the System Filter Magic II.
Most of the problems reported in these systems are caused by improper operation. Careful attention to the step-by-step instructions ensures that the system works as intended.










Press handle to open right.

DO NOT use the cleaning rod to hammer on the drain valve or other objects. Damage to the valve ball will cause leaks and nullify Frymaster guarantee.


Downward and rear filters
Press.

Press the drain handle to the left for closing.


Press filter handle up and forward.



CHAPTER 5: PREVENTIVE MAINTENANCE
5.1 Preventive maintenance tests and service of the frying machine
Inspection of the frying machine and accessories for damage
Look for loose or frayed wires and cables, leakages, foreign matter in the frying tub or cabinet, and other signs that indicate that the fries machine and accessories are not ready or safe to operate.
Cleaning the inside and outside of the frying cabinet
Clean the interior of the frying cabinet with a dry, clean cloth. Wipe all accessible metal surfaces and components to remove grease/oil residues and dust.
Clean the exterior of the frying machine cabinet with a clean cloth moistened by dishwasher solution to remove grease/oil, dust and fuse from the fries machine cake.
Drying and cleaning of the frying tub
During normal use of the frying machine, a layer of charred fat or fry grease is slowly formed. oil on the inside of the frying tub. This layer must be removed regularly in order to keep the efficiency of the frying machine high.
If the frying machine is not equipped with a built-in filter system, the fat or oil must be discharged into another suitable container. (For safe and practical drainage and disposal of used fat or oil, Frymaster recommends) the use of: Fat disposal unit (FEE). The FEE is available from your local distribution company.


DO NOT hit the drain valve. This damages the valve ball of the drain valve and prevents complete closing; thus, the valve becomes leaky.


Cleaning of detachable parts and accessories
As in the case of frying tubs, a deposit of carbonated fat/oil is formed on removable parts and accessories such as baskets, settling plates or fish plates.
Wipe all removable parts and accessories with a clean cloth moistened in dishwasher detergent. Rinse all parts and dry well.
Checking the calibration of the analog controller thermostat button
(This test is only applicable to machines with analogue controllers).)
a. The adjusting screw in the thermostat control button is released until the knob on the shaft can be rotated freely.
b. Turn the button until the index line on the button matches the mark for the thermometer or pyrometer reading.
c. Hold the button and tighten the setscrew carefully.
d. Check the thermometer or pyrometer reading and setting of the thermostat control button when burners are next fired.
e. Steps 4.a. to 4.d. Repeat until the thermometer or pyrometer reading and button setting are within ±2 °C (5°F). If for any reason no calibration can be achieved, notify a service centre authorised by the factory.
Checking the setpoint accuracy for Magic III computer
(This test is only valid for machines with Computer Magic III controllers.)

A protective plate or sheet metal member, i.e. a protective plate assembly prevents accidental access to the fan assembly. The respective embodiment depends on the present configuration of the frying machine and the land for which the friting machine was manufactured. However, the protective plate is always fastened to the cabinet frame by sheet-metal screws. The screws with which the protective plate or sheet metal is formed, i.e. the assembly is fastened to the cabinet frame, and pulling the protective plate from the frying machine. The combustion air blower assembly is now accessible.



Remove these components. (In black FASCO blowers, there are three nuts). Silver Kooltronics fans have three screws.



Removed)
The air/gas mixture is correctly adjusted if the pressure at the burner distributor corresponds to the value in the corresponding table on page 5-8 and the burners flame is pale orange-red. If a blue flame is observed or dark spots are visible on the burner surface, the air/gas mixture must be regulated.
Control of the air/gas mixture (CE) equipment and CE equipment manufactured after April 1999
On the side of the fan housing opposite to the motor is a plate with one or two securing nuts. Remove the nut(s) sufficiently to allow for displacement of the plate. The plate now enlarges or closes the air intake opening for so long. Reduce the size until the flame is bright orange-red. Carefully hold the plate in this position and tighten the securing nut(s).
Typical fan assembly other than CE type blower assembly for appliances
manufactured after April 1999
Control of the air/gas mixture CE devices manufactured until April 1999 CE devices manufactured until April 1999 inclusive are provided with a protective assembly in front of the blowers. An air closing flap on the end face of the protective assembly regulates the supply of air to the fan inlet. To adjust the closing flap, release the securing screws and move the flap to the right or left until a bright orange-red flame is obtained. Carefully hold the closing flap in this position and tighten the securing screws.


Typical CE fan protection panel assembly for devices manufactured until April 1999

NOTE: This procedure is not required for frying machines exported to CE countries.
Testing the pressure in the burner distributor
Cleaning of the gas valve vent line

5.2 Preventive maintenance tests and servicing of the installed filter system

The FootPrint III or Filter Magic II filtration systems do not require regular preventive maintenance and service except for daily cleaning of the filter pan with a hot water solution and detergent.
If it is found that the pumping capacity of the system is low or non-existent, check whether the filter tray screen has been inserted at the bottom in the tub and the filter paper must be on top of the screen. Check if the O-ring(s) are present and in good condition. With FootPrint III systems, there is a single O-ring at the bottom of the filter tub. In filter Magic II systems, there is an O-ring at the bottom of the tub and two O-Rings on the screw connection inside the back of the cabinet.
Discharge the pressure shower immediately after each use. If oil is leaked at the point where the pressure shower is connected to the frying tub, examine or retrieve the condition of the O-ring and seal on the connection. Check if they are present. If blockage is suspected, unscrew the cleaning plugs at the frame corners. Place the frame in a hot water tub for several minutes to dissolve solid fat/oil build-up. Using a long, narrow bottle brush, hot water and dishwasher detergent to clean the interior of the lines. As needed, insert a straight curved paper clip or wire of similar thickness into the holes in the frame to remove solid grease or other blockage. Rinse with hot water, dry well and reinsert the stoppers before reuse.


5.3 Annual/Regular System Audit
This equipment must be inspected and adjusted regularly by a qualified service technician; this should form part of a regular kitchen maintenance program.
Frymaster recommends that this device be tested at least once a year by a factory-authorized service technician as follows:
Frying machine · Built-in filtering system

− When the filter pan is empty, set one oil return handle after another on ON. Check whether the pump is activated and that bubbles in fat/oil (or gurgling noise from the pressure shower connection are audible) appear in the associated frying pan.
− All oil return valves close (i.e. Set all oil return handles OFF. Check the correct operation of each oil return valve by activating the filter pump with one of the oil return handle microswitches. No air bubbles shall be visible in any of the frying pans (or no gurgling noise may be heard at the pressure shower connection).
− Check whether the filter tray is properly prepared for filtration, and then frying with
Dry fat/oil heated to 177 °C (350°F) and close the frying trough drain valve. Set the oil return handle to ON. Wait until all the fat/oil has been pumped back into the frying tub (this is complete when blisters appear in the fat or oil, or if for pressurised fryers the flow of oil from the pressurized shower ends). Set the oil return handle OFF again. The frying tub should refill within a maximum of 2 minutes and 30 seconds.

CHAPTER 6: TROUBLESHOOTING BY THE
OPERATORS
6.1.Introduction
This chapter is a short troubleshooting guide for some problems that may occur while this frying machine is in operation. It is intended to help the user correct problems on this device or at least accurately diagnose them. While this chapter covers most common problems, it can also cause issues that are not covered here. In such cases, the staff of Frymaster’s technical support department will be happy to assist you in identifying and solving the problem.
When troubleshooting a problem, an elimination procedure should always be used, starting with the simplest solution to the most complicated. But the most important thing is to get a clear idea why an issue occurred. Steps to ensure that this does not happen again must be part of any corrective action. If a controller is not working due to poor connection, all other connections must also be checked. If a fuse burns out again and again, the reason for this must be determined. Always note that the failure of a small component can often be an indication of possible failure or incorrect functioning of a more important component or system.
Some of the debugging measures recommended in this chapter include removing suspect components and replacing them with known good parts. Whenever required, look up details in Section 6.7.
If there is any doubt as to what action should be taken, notify Frymaster’s technical maintenance department or your local service agency authorised by the FryMaster plant.
Before calling a maintenance representative or the Frymaster HOTLINE (1-800-551-8633) carry out the following tasks:
This device may have several power supply points. Unplug all power cables before maintenance.
Inspection, testing and repair of electrical components may only be carried out by qualified service personnel.

6.2 Troubleshooting of frying machines with Computer Magic III, basket lifter timer or digital controller
A. The controller is not turned on. A. The controller with the ON/OFF
Switch on.
B. Ensure that the frying machine:
B. No electricity to the frying machine.
connected and the disconnect switch is not tripped.
C. If available, a functioning
Use cable harness instead of the suspect. If the frying machine is working correctly, order a replacement cable tree from FASC.
C. Damaged computer/controller
Wiring harness.
controller.
D. If available, a functioning
Use computer/controller instead of the suspect. If the frying machine is working correctly, order a replacement from FASC.
D. Computer/controller has failed.
If available, use a working harness instead of the suspect. If the frying machine is working correctly, order a replacement cable tree from FASC. A. The drain valve is not quite
Damaged computer/controller harness or connector.
and the alarm sounds.
A. Set ON/OFF switch to OFF;
Close the drain valve(s) completely, and set ON/OFF switches to ON. B. Gas valve is not open. B. Gas valve button on EIN pose.
Closed.
C. Check that all manual
C. Manual gas shut-off valve is:
shut-off valves are open in the system. Check that the main gas supply valve is open.
Closed.
D. Check if the quick release is
and the alarm sounds. The heater is a, but
D. Incorrect connection of the
is permanently connected to the frying machine on the flexible gas line.
Quick gas supply closure.
Burners do not ignite.
Check that the combustion air blower is running. If not, notify the FASC for service. If the combustion air blower is functioning, clean and adjust it in accordance with the instructions set out in Chapter 5 of this user manual.
E. Blocked or failed
Combustion air blower.

A. If available, a functioning
Use computer/controller instead of the suspect. If the frying machine is working correctly, order a replacement from FASC.
A. Computer/controller has failed.
normal and
B. If available, a functioning
Use cable harness instead of the suspect. If the frying machine is working correctly, order a replacement cable tree from FASC. Frying machine leaves
Do not light and the chest does not run. B. Damaged computer/controller
Wiring harness.
Melting cycle only slowly. Display showing:
Clean and adjust according to the instructions in Chapter 5 of this user manual.
Contaminated or blocked combustion air blower.
Clean and adjust according to the instructions in Chapter 5 of this user manual.
Contaminated or blocked combustion air blower.
However, recovery during frying is
Slowly.
A. Polluted or blocked
A. In accordance with the instructions in Chapter 5
clean and adjust the user instructions. B. Pollution or blockage
Combustion air blower.
The frying machine works normally, but generates a burner when the torches are started.
B. In accordance with the instructions in Chapter 5
Gas valve ventilation line (CE frying machines only).
clean this user manual.
Bang noise. C. Defective combustion air blower. C. If the blower is slow
starts, the FASC for service notify. Display showing:
If available, use a working computer/controller instead of the suspect. If the frying machine is working correctly, order a replacement from FASC. Computer does not switch to programming
and the alarm sounds, but
Computer/controller has failed.
(Misplacement alarm).
If available, use a working computer/controller instead of the suspect. If the frying machine is working correctly, order a replacement from FASC. The heater lamp is one and
Mode or some keys cannot be
Computer/controller has failed.
actuated.
Flower safety on interface card or ignition module it failed.
Replace the backup in accordance with instructions set out in Section 6.6 of this Chapter.
Blowers are running, but burners do not ignite.

PROBLEM LIKE CAUTION CORRECTURE Heater lamp is
If available, use a working computer/controller instead of the suspect. If the frying machine is working correctly, order a replacement from FASC.
initial commissioning. Display showing:
Computer/controller has failed.
And it sounds like a
Alarm.
6.3 Defect detection on frying machines with analog controller (solid body)
A. Ensure that the frying machine:
A. No electricity to the frying machine.
connected and the disconnect switch is not tripped.
B. If available, a functioning
Use cable harness instead of the suspect. If the frying machine is working correctly, order a replacement cable tree from FASC.
B. Damaged controller cable tree.
Controller, frying machine heated
Not.
C. If available, a functioning
Use controller instead of the suspect. If the frying machine is working correctly, order a replacement from FASC.
C. The controller has failed.
If available, use a working harness instead of the suspect. If the frying machine is working correctly, order a replacement cable tree from FASC.
The mains light is ON, the fault lamp is ONE.
Damaged controller cable tree.
AUS.
A. Set ON/OFF switch to OFF;
A. The drain valve is not quite
Close the drain valve(s) completely, and set ON/OFF switches to ON.
Closed.
B. Gas valve is not open. B. Gas valve button on EIN pose.
C. Check that all manual
C. Manual gas shut-off valve is:
shut-off valves are open in the system. Check that the main gas supply valve is open.
The mains light is ON, the fault lamp is ONE.
Closed.
Heating mode lamp is ON. Burners igniting
D. Check if the quick release is
D. Incorrect connection of the
is permanently connected to the frying machine on the flexible gas line.
Quick gas supply closure.
Not.
E. Check that the combustion-
Air blower running. If not, notify the FASC for service. If the combustion air blower is functioning, clean and adjust it in accordance with the instructions set out in Chapter 5 of this user manual.
E. Blocked or failed
Combustion air blower.

A. If available, a functioning
Use controller instead of the suspect. If the frying machine is working correctly, order a replacement from FASC.
A. The controller has failed.
Heating mode light switches on normally
and off. The fan is running
B. If available, a functioning
Use cable harness instead of the suspect. If the frying machine is working correctly, order a replacement cable tree from FASC. Frying machine leaves
Do not ignite. B. Damaged controller cable tree.
Slowly. The heating mode lamp shall be:
Clean and adjust according to the instructions in Chapter 5 of this user manual.
Contaminated or blocked combustion air blower.
ONE. Causal lamp
leaving the melting cycle.
Clean and adjust according to the instructions in Chapter 5 of this user manual.
Contaminated or blocked combustion air blower.
However, recovery during frying is
Slowly.
A. In accordance with the instructions in Chapter 5
A. Blocked combustion air blower.
clean and adjust the user instructions. B. Pollution or blockage
The frying machine works normally, but generates a burner when the torches are started.
B. In accordance with the instructions in Chapter 5
Gas valve ventilation line (CE frying machines only).
clean this user manual.
Bang noise.
C. If the blower is slow
starts, the FASC for service notify. The heating mode lamp is on and the fan runs,
C. Defective combustion air blower.
Flower safety on interface card or ignition module has failed.
Replace the backup in accordance with instructions set out in Section 6.6 of this Chapter.
Not.
A. If available, a functioning
Heating mode light switches on normally
Use controller instead of the suspect. If the frying machine is working correctly, order a replacement from FASC.
A. The controller has failed.
and off, and the frying machine is working normally.
B. If available, a functioning
Use cable harness instead of the suspect. If the frying machine is working correctly, order a replacement cable tree from FASC.
B. Damaged controller cable tree.
(Misplacement alarm).

The following is a PROBLEM LIMIT CAUTION CORRECTURE:
ON, but power switches OFF. After
If available, use a working controller instead of the suspect. If the frying machine is working correctly, order a replacement from FASC.
switches off the frying machine until the fault light is
The controller has failed.
switches on. Frying trough
210 °C (410°F).
6.4 Defect detection on the built-in filtering system
A. If the pump is reset after
The temperature overload switch was running normally, the pump had overheated.
A. Temperature overload switch was used in
overheated engine.
Always filter the oil or fat at about frying temperature.
TestIf the pump suddenly stopped during filtration, especially after several filtering cycles, it was likely that the pump motor overheated. Set the filter handle OFF, allow the pump to cool for at least 45 minutes and press the reset button on the pump motor. Try to turn the pump on.
Wait for about 10 minutes until the pump motor cools down when two full frying tubs have been filtered immediately behind each other.
Test the filter paper between filtration operations. Exchange the paper if there are strong deposits.
Pump does not start.
B. Filter handle microswitch is:
defaulted.
the filtration.
Test: In a frying machine with several fryers, try to actuate the pump using another handle. When the pump starts, either the handle micro-switch is oriented incorrectly or has failed.
B. When the switch is loose, its
tighten nuts and screws. Make sure that the lever of the microswitch presses firmly against the switch when the handle is in ON position.
When the handle is set to ON, the lever on the microswitch must press firmly against the switch. If this is the case, the switch has failed. Otherwise, the switch is loosely and/or incorrectly aligned.
If the switch has failed, FASC will notify.
Initial input- · Perature is over · Pump stops during

C. Pump blocking is carried out in the
C. The pump is blocked.
Usually caused by excessive deposits in the pump, due to improperly sized filter paper or because of unused crumb screen. Advise FASC to remove the blockage.
TestClose the drain valve. Set the filter handle OFF, allow the pump to cool for at least 45 minutes and press the reset button on the pump motor. Drag the filter tub from the frying machine and activate the pump. If the pump motor hums and stops, then the pump is blocked.
Ensure that the filter paper is in the correct format and installed correctly. The crumb sieve must also be used.
A. For proper filtration, the
oil or fat have approximately 177 oC (350 oF). At lower temperatures, the oil/fat becomes too thick to simply flow through the filter medium; this leads to slower oil recirculation and finally overheating of the filter pump motor. Ensure that the oil/fat is approximately at frying temperature before it is drained into the filter tub. B. Incorrectly installed or prepared
A. Frying fat/oil is too cold for filtration.
Pump starts, but no oil flow or only very slow oil flow.
components of the filter pan.
B. Remove the oil from the filter pan
and replace the filter paper. Ensure that the filter screen Underground the paper is used.
TestClose the drain valve. Set the filter handle to OFF, pull the tub (and pressure shower if any) out of the machine. Reset the filter handle to ON.
C. If it does not cause the problem
If the filter is removed, it is likely that the suction pipe will be blocked. Remove the blockage with a thin, flexible wire. If the blocking cannot be removed, FASC will notify.
If a strong airflow emerges from the oil return connection or pressure shower connection, the problem is due to the components of the filter pan.
(Continued on the next page)
(Continued from · last page)

PROBLEM PROBABLE CAUSES CORRECTIVE ACTION C. Incorrectly installed or prepared
components of the filter pan.
D. Remove the oil from the filter pan
and replace the filter paper. Ensure that the filter screen Underground the paper is used.
TestClose the drain valve. Set the filter handle to OFF, pull the tub (and pressure shower if any) out of the machine. Reset the filter handle to ON.
If this does not eliminate the problem, it is likely that the filter intake pipe will be blocked. Remove the blockage with a thin, flexible wire. If the blocking cannot be removed, FASC will notify.
If a strong airflow emerges from the oil return connection or pressure shower connection, the problem is due to the components of the filter pan.
last page) D. Incorrectly installed or prepared
D. Check if the O-rings of the filter
components of the filter pan.
Then they are in good condition and present.
TestClose the drain valve. Set the filter handle OFF and pull the tub (and pressure shower, if any) out of the machine. Reset the filter handle to ON.
Replace the filter paper. In this case, it is ensured that the filter screen Underground The paper is used correctly.
When using the Magnasol filter assembly, check that the O-ring is present on the filter screen screw connection and in good condition.
If a strong airflow emerges from the oil return connection or pressure shower connection, the problem is due to the components of the filter pan.
A. Openings are clogged or solid
Fat blocks pressure shower.
A. The pressure shower according to instructions
Test: Check whether fat/oil does not leak out of the openings in the frame along the pressure shower seal. If this is the case, the pressure shower is blocked.
in Chapter 5 of this user manual.
B. Pressure shower O-rings and seal
B. Check if the O-rings and
Not right.
Missing or worn out.
seal and in good condition.
C. Paper is missing in the filter trough. (This is)
causes too much pressure in the oil return lines and thus a strong flow through the pressurized shower as well as splashing out of oil along the seal.
C. Check if the filter paper is correct
is inserted into the filter trough.
(Continuation of ·) Pressurized shower sprayed

6.5 Defective search on the basket lifter

Smear the rack-lifter rods with LubriplateTM or an equivalent light white grease.
6.6 Replacement of the ignition module fuse

On machines in which the ignition module has no fuse, the upper fuse on the interface card must be replaced.
Depending on the production date, fryers with undivided fry troughs may have either one or two ignition modules. If only one is available, the backup is mounted on the interface card.
Machines with divided frying tubs have two ignition modules. The fuse is located on the left side of the module. If the modules do not contain fuses, they are on the interface card.

Ignition module

6.7 Replacement of the controller or the controller cable tree





TEL 1-318-865-1711 FAX (parts) 1-319-219-7140 (Techn). Support 1-318-219-7135