- DEAN D, SCFD, and CFD Models - DEAN HD and SCFHD Models - FRYMASTER FPD65 and FPHD65 Models
Please read all sections of this manual and retain for future reference.

Dean, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633 MAY 2007 PRINTED IN THE UNITED STATES


qualified professional should perform installation, maintenance, and repairs. Installation, maintenance, or repairs by unqualified personnel may void the manufacturer’s warranty. See
Chapter 1 of this manual for definitions of qualified personnel.

the country and/or region in which the appliance is installed. See NATIONAL CODE
REQUIREMENTS in Chapter 3 of this manual for specifics.
technical procedures and may not conform to onsite management operational procedures.
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept
any interference received, including interference that may cause undesired operation. While
this device is a verified Class A device, it has been shown to meet Class B limits.
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set
out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communications du Canada.

service instructions thoroughly before installing or servicing this equipment. Only qualified
service personnel may convert this appliance to use a gas other than that for which it was originally configured. See Chapter 1 of this manual for definition of qualified service personnel.
licensed plumber or pipe fitter.


anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all
from slips or contact with the hot oil.
other appliance.

must be posted in a prominent location. This information can be obtained from the local gas
company or gas supplier.

at the end of frying operations each day. Some food particles can spontaneously combust if left
soaking in certain shortening material. Additional information can be obtained in the filtration
manual included with the system.

the fryer under a hood. Questions? Call the Frymaster and Dean Service Hotline at 1-800-551-

the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for
EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER AND DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS,
AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER AND DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER
WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED
SERVICE CENTER.





The Dean Decathlon Series gas model family (D models) has been approved by the European Union (EU) for sale and installation in the following EU countries: AT, BE, KE, KD, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE. The Dean High Efficiency Decathlon Series gas model family (HD models) has not been approved by the European Union (EU) for sale or installation in EU countries. Information regarding this fryer is for non-members of the EU only. This manual is applicable to and valid for all Dean Decathlon gas units sold in English- speaking countries, including those in the European Union. This manual is applicable to and valid for all Dean High Efficiency Decathlon gas units sold in English-speaking countries, excluding the European Union. Where conflicts exist between instructions and information in this manual and local or national codes of the country in which the equipment is installed, installation and operation shall comply with those codes. This appliance is only for professional use and shall be used by qualified personnel as defined in Section 1.7. 1.2 After Purchase In order to improve service, have the following chart filled in by the Dean Authorized Service Technician who installed this equipment.
Address Telephone/Fax Model Number Serial Number Gas Type 1.3 Ordering Parts Customers may order parts directly from their local factory authorized service center. For this address and phone number, contact your factory authorized service center or call the Dean Service Hotline phone number, 1-800-551-8633. To speed up your order, provide the model number, serial number, gas type, part needed, item part number (if known), and quantity needed.
Authorized Service Technician/FASC

1.4 Service Information Call the Dean Service Hotline, 1-800-551-8633, for the location of your nearest factory authorized service center. To assist you more efficiently, always provide the service technician with the model number, gas type, serial number, and the nature of the problem. 1.5 Computer Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and may cause harmful interference to radio communications if not installed and used in accordance with the instruction manual. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense. The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. 1.6 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below.

1.7 Service Personnel A. Qualified and/or Authorized Operating Personnel
1. Qualified service personnel are those who are familiar with Dean equipment and have been authorized by Dean to perform service on Dean equipment. All authorized service personnel are required to be equipped with a complete set of service parts manuals and stock a minimum amount of parts for Dean equipment. A list of Dean Factory Authorized Service Centers (FASCs) was included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Dean warranty on your equipment.

A. Check that the container is upright. Use an outward prying motion - no hammering - to
remove the carton. Unpack the fryer carefully and remove all accessories from the carton. Do not discard or misplace these, as they will be needed.
B. After unpacking, immediately check the equipment for visible signs of shipping damage. If
damage has occurred, contact the carrier and file the appropriate freight claims. Do not contact the factory. Shipping damage responsibility is between the carrier and the dealer.
If your equipment arrives damaged:
C. Frying systems with built-in filtration: Take off the filter support brace and remove the
filter pan from the cabinet.
carton is furnished with three unloading ramps. Remove the braces from the front casters by taking out the securing bolts. Carefully roll the unit down the ramps from the front (cooking side).
E. Remove all plastic skin from sides, front, and doors of the fryer(s). Failure to do this prior to
initial fryer operation will make it very difficult to remove later. 2.2 General Qualified, licensed, and/or authorized installation or service personnel only (as defined in Section 1.6) should perform the following:

2.2 General (cont.) Where conflicts exist between instructions and information in this manual and local code or national codes, or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed.

Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Receiving and Unpacking Equipment in Section 2.1.)

used. Questions? Call 1-800-551-8633. 2.3 Product Description Dean Decathlon Series gas fryers are energy efficient, tube-style, gas-fired units. All units are shipped completely assembled with accessories packed inside the frypot. All units are adjusted, tested and inspected at the factory before shipment. Sizes, weights and input rates of all models are listed in this manual.

the inherent hazards of operating a hot oil frying system, particularly the aspects of
system operation, oil filtration, draining and cleaning procedures. 2.4 Principles of Operation The incoming gas flows through orifices and is mixed with air in the burners to create the correct ratio for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot light. Internal diffusers slow the flame as it goes through the burner tube. This slow, turbulent flame increases heat transfer to the walls of the tubes to heat the oil more efficiently.

2.5 Rating Plate
This is attached to the inside front door panel. Information provided includes the model and serial number of the fryer, BTU/hr input of the burners, outlet gas pressure in inches W.C. and whether the unit has natural or propane gas orifices.
plate.
800-551-8633.
this chapter. A. General: Only licensed personnel should install any gas-fired equipment.
1. A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for safety and ease of future service. 2. Dean Decathlon Series gas fryers require 120VAC 60 cycle or 230VAC single-phase 50 Hz (International) electrical service and are equipped with a 16-3 SJT grounded flexible power cord for a direct connection to the power supply. Amperage draw for each unit depends on the accessories supplied with the unit/system. B. Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design-
certified for the following installations:

2.6 Pre-installation (cont.) C. Installation Standards
American National Standard Institute CAN 1-B149 Installation Codes ANSI Z83.11 Canadian Gas Association American Gas Association 55 Scarsdale Road 8501 E. Pleasant Valley Road Don Mills, ONT, M3B 2R3 Cleveland, OH 44131 National Electrical Code Canadian Electric Code c22.1, part 1 ANSI/NFPA #70 Canadian Standards Association American National Standard Institute 178 Rexdale Blvd. 1430 Broadway Rexdale, ONT, M9W 1R3 New York, NY 10018 NFPA Standards #96 and #211 National Fire Protection Association 470 Atlantic Avenue Boston, MA 02110
of unacceptable concentrations of substances harmful to the health of personnel in
the room in which it is installed.
Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow as well as for service and maintenance.
A. Do not connect this fryer to an exhaust duct.
B. Correct installation and adjustment will ensure adequate airflow to the fryer system.
C. A commercial, heavy-duty fryer must vent its combustion wastes to the outside of the building.
A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan must be provided in the wall above the unit, as exhaust gas temperatures are approximately 800-1000°F (427-538°C). Check air movement during installation. Strong exhaust fans in the exhaust hood or in the overall air conditioning system can produce slight air drafts in the room.

2.7 Air Supply and Ventilation (cont.)
D. Do not place the fryer’s flue outlet directly into the plenum of the hood, as it will affect the
gas combustion of the fryer.
E. Never use the interior of the fryer cabinet for storage or store items on shelving over or
behind the fryer. Exhaust temperatures can exceed 800°F (427°C) and may damage or melt items stored in or near the fryer. F. Adequate distance must be maintained from the flue outlet of the fryer(s) to the lower edge
of the filter bank. Per NFPA Standards No. 96, a minimum of 18 in. (45 cm) should be maintained between the flue(s) and the lower edge of the exhaust hood filter.
G. Filters and drip troughs should be part of any industrial hood, but consult local codes before
constructing and installing any hood. The duct system, the exhaust hood and the filter bank must be cleaned on a regular basis and kept free of grease. 2.8 Equipment Installed at High Altitudes
A. The fryer input rating (BTU/hr) is for elevations up to 2,000 ft (610 m). For elevations
above 2,000 ft (610m), the rating should be reduced four percent for each additional 1,000 ft (305m) above sea level.
B. The correct orifices are installed at the factory if operating altitude is known at time of the
customer’s order.

CHAPTER 3: INSTALLATION
A. Initial Installation: If the fryer is installed with legs, do not push the fryer to adjust its
position. Use a pallet or lift jack to lift the fryer slightly, and then place the fryer where it is to be installed.
installed. Do not slide the fryer on the legs.
C. If a leg becomes damaged, contact your service agent for immediate repair/replacement.
A. All Installations: If the floor is uneven or has a definite slope, place the fryer on a level
platform.
B. Place a carpenter's spirit level across the top of the fryer and level the unit both front-to-
back and side-to-side. If it is not level, the unit may not function efficiently, the oil may not drain properly for filtering and in a line-up it may not match adjacent units.
C. Adjust to the high corner and measure with the spirit level. If floor is uneven, level the
unit with the screw adjustments on each leg (ensure minimum clearances as discussed in Chapter 2 are maintained during the leveling procedure).
D. Re-leveling: If the fryer is moved, re-level the fryer following the above instructions.
E. The install must be reviewed at the time of installation to ensure it meets the intent of
these instructions.
movement to avoid damage and possible bodily injury.
must be removed from the fryer before attempting to move it to avoid oil spills, and
the falls and severe burns that could occur. This fryer may tip and cause personal
injury if not secured in a stationary position.

3.3 Installing Casters and Legs
A. Install casters and/or legs near where the fryer is to be used, as neither is secure for long
transit. Decathlon Series gas fryers cannot be curb-mounted and must be equipped with either legs or casters provided.
B. After unpacking, use a pallet or lift jack to raise the unit before installing the casters.
C. Align the caster or leg base holes with the leg support assembly and insert bolt. Install
the washers and nut hand tight, and repeat for all four holes in caster/leg base assembly.
D. Tighten the caster/leg against the leg support assembly by using appropriate tools.
Ensure that all four bolts are evenly tightened. Tighten the bolts to 50 inch-lbs. (5.65 Nm) torque.
E. For fryer with casters, there are no built-in leveling devices. The floor where the
fryers are installed must be level.

Front Channel or Rear Channel
Front or Rear Leg with Mounting Plate

a moveable or portable installation, Dean optional equipment casters must be used.

3.4 Gas Connections

to remove all foreign material. Foreign material in the burner and gas controls will
cause improper and dangerous operation. U.S. NATIONAL CODE REQUIREMENTS This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration. This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect equipment stamped "NAT" only to natural gas and that stamped "PRO" only to LP (Propane) gas.
Installation shall be made with a gas connector that complies with national and local codes.
Quick disconnect devices, if used, shall likewise comply with national and local codes.

plate located on the back of the fryer door.

local gas company or FASC should be contacted immediately to rectify the problem. The gas supply (service) line must be the same size or greater than the fryer inlet line. This fryer is equipped with a ¾" (22 mm) male inlet. The gas supply line must be sized to accommodate all the gas-fired equipment that may be connected to that gas supply. Consult your contractor, gas company, supplier, or other knowledgeable authorities.

Gas Types Number of Fryers 1 2 to 3 4 or more (*) Natural Gas ¾" (22 mm) 1" (28 mm) 1¼" (35 mm) Propane (LP) Gas ½" (15 mm) ¾" (22 mm) 1" (28 mm) (*) When exceeding 18 feet for a configuration of more than four fryers, it is necessary to provide
a 1¼" (35 mm) rigid gas connection.

3.4 Gas Connections (cont.)

Gas Supply Type and Pressure Gas Supply Type Gas Supply Pressure Natural Gas 6-10" W.C. (Dynamic) Propane (LP) Gas 11-13" W.C. (Dynamic)
line if the test pressure is ½" PSI [3.45 kPa (14 inches W.C.)] or greater to avoid
damage to the fryer’s gas piping and gas valve(s).
used and all connections must be tested with a solution of soapy water before
lighting any pilots.
Never use matches, candles, or any other ignition source to check for leaks. If gas
odors are detected, shut off the gas supply to the appliance at the main shut-off
valve and immediately contact the local gas company or an authorized service
agency for service.
unit.
threading chips, or any other foreign matter before installing into a service line. If the intake pipes are not clear of all foreign matter, the orifices will clog when gas pressure is applied. Seal pipe joints with a sealant resistive to LP gas. When using thread compound on gas piping, use very small amounts and only on male threads. Use a pipe thread compound that is not affected by the chemical action of LP gases. DO NOT apply thread compound to the first two pipe threads—doing so will cause clogging of the burner orifices and control valve. B. Manual shut-off valve: This gas service supplier-installed valve must be installed in the
gas service line ahead of the fryers in the gas stream and in a position where it can be reached quickly in the event of an emergency. C. Regulating Gas Pressure: The fryer and shut-off valve must be disconnected from the gas
supply during any pressure testing of the system. NOTE: External gas regulators are not normally required on this fryer. A safety control valve protects the fryer against pressure fluctuations. If the incoming pressure is in excess of ½" PSI (3.45 kPa/35 mbar), a step-down regulator is required.

3.4 Gas Connections (cont.)
line if the test pressure is ½" PSI [3.45 kPa (14 inches W.C.)] or greater to avoid
damage to the fryer’s gas piping and gas valve(s).
manometer.
1. Check the rating plate for specific manifold gas pressures. Natural gas units normally require 4" W.C. (10.0 mbar), and propane/LP units normally require 11" W.C. (27.5 mbar) gas pressure. 2. Confirm that the arrow forged into the bottom of the regulator body, which indicates gas flow direction, is pointed downstream towards the fryers. The air vent cap is also part of the regulator and should not be removed. If a vent line from the gas pressure regulator is used, it should be installed in accordance with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-(latest edition) in the U.S. and appropriate national or European Community (CE) standards in the European Union.
new connections.
E. Regulators can be adjusted in the field, but it is recommended that qualified service personnel adjust a
regulator only if it is known to be out of adjustment or serious pressure fluctuations have been found and can not be solved another way.
F. Only qualified service personnel should make adjustments to the regulators. G. Orifices: The fryer can be configured to operate on any available gas. The correct safety control valve,
appropriate gas orifices, and pilot burner are installed at the factory. While the valve can be adjusted in the field, only qualified service personnel should make adjustments with proper test equipment. H. Flexible Couplings, Connectors and Casters: If the fryer is to be installed with flexible couplings and/or
quick-disconnect fittings, the installer must use a heavy-duty AGA design-certified commercial flexible connector of at least ¾" NPT (with suitable strain relief), in compliance with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69-(latest edition) and Addenda Z21.69a-(latest edition). Quick disconnect devices must comply with the Standard for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41-(latest edition).

3.5 Gas Connections (cont.)

I. After hook-up, bleed the gas line of air to ensure that the pilot light will ignite quickly.
AUSTRALIAN REQUIREMENTS To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.

2.18(#44) 1.40(#54) 810-2050 810-2324 2 2 10 27.5 4 11
2.08(#45) 1.32(#55) 14-0067-45 810-2441 4 4 10 27.5 4 11
2.53(#39) 1.51(#53) 810-2048 810-2059 4 4 10 27.5 4 11
2.44(#41) 1.51(#53) 14-0067-41 810-2059 4 4 10 27.5 4 11
2.08(#45) 1.32(#55) 14-0067-45 810-2441 5 5 10 27.5 4 11
2.53(#39) 1.51(#53) 810-2048 810-2059 5 5 10 27.5 4 11
2.26(#43) 1.40(#54) 810-2049 810-2324 5 5 10 27.5 4 11
2.58(#38) 1.61(#52) 810-2062 810-2063 5 5 10 27.5 4 11
2.26(#43) 1.40(#54) 810-2938 810-2939 4 4 10 27.5 4 10
2.26(#43) 1.40(#54) 810-2938 810-2939 5 5 10 27.5 4 10

3.5 Gas Specifications


Switching to a different type of gas without installing the proper conversion components may result in fire. NEVER ATTACH THIS APPLIANCE TO A GAS
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as

(remove cover screw to
(remove cover screw to
connection.
Typical non-CE gas valve for electronic-ignition equipped fryers.

3.7 Electrical Connections The fryer when installed must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70-(latest edition).
receptacle. DO NOT CUT, REMOVE, OR OTHERWISE BYPASS THE GROUNDING
PRONG ON THIS PLUG! The rating plate and wiring diagram are located inside the front door. The fryer is equipped with a 120VAC single-phase 60-hertz system (Domestic), or 230VAC single-phase 50-hertz system (International/CE). Do not cut or remove the ground prong from the power cord plug. Do not attempt to use the fryer during a power outage.
the OFF position in case of a prolonged power outage. Do not attempt to operate
this appliance during a power outage.


the inherent hazards of operating a hot oil frying system, particularly the aspects of
system operation, oil filtration, draining and cleaning procedures. Cleaning: New units are wiped clean with solvents at the factory to remove any visible signs of dirt, oil, or grease remaining from the manufacturing process, and then coated lightly with oil. Before any food preparation, wash thoroughly with hot, soapy water to remove any film residue and dust or debris then rinse out and wipe dry. Also wash any accessories shipped with the unit. Close the drain valve completely and remove the crumb screen covering the heating tubes. Ensure the screws holding the thermostat and high-limit control sensing bulbs into the frypot are tight.
Typical high-limit/sensor probe locations and mounting hardware.

a tight fit and should only be removed for cleaning.

water or cooking oil/shortening before lighting the burners. Failure to do so will
damage the frypot and may cause a fire.


4.1.1 Pilot Lighting Procedures, Standing Pilot Only Initial Pilot Lighting: All Dean fryers are tested, adjusted and calibrated to sea level conditions before leaving the factory. Adjustments to assure proper operation of pilot may be necessary on installation to meet local conditions, low gas pressure, differences in altitude and variations in gas characteristics. These adjustments correct possible problems caused by rough handling or vibration during shipment, and are to be performed only by qualified service personnel. These adjustments are the responsibility of the customer and/or the dealer and are not covered by the Dean Industries warranty. The inlet pipe at the lower rear of the fryer brings incoming gas to the pilot safety control valve, then to the pilot and main burners. The pilot is located high in the cabinet center, at the base of the frypot. Light the pilot as follows:

Piezo Ignitor: Turn the gas cock dial on the control valve to "Pilot", and then repeatedly press the piezo ignitor button while depressing the gas valve knob until the pilot lights. Continue to hold the knob in for 1 minute. Release the knob. The pilot should remain lit.
Piezo ignitor button

4.1.2 Pilot Lighting Procedures, Electronic Ignition Systems
WARNING Never use a match or taper to light pilot on this ignition system. 1. Turn gas "ON". 2. Turn electric power "ON" with the appropriate rocker switch or controller/computer. 3. The ignition module will energize the pilot gas supply and the igniter. The igniter spark will ignite the pilot gas. The presence of the pilot flame is then proved by a flame sensor, which sends a signal to the main gas supply, opening the valve. The operating thermostat or computer/controller controls the fryer after ignition.

re-established. 4. If the pilot flame fails, the ignition module will shut down and lock out the system. To restart, turn the electric power "OFF", wait approximately 5 minutes for the system to recycle itself, and then turn the power "ON" again. Repeat Steps 1-3. 4.2 Boil-Out Procedure
boils over, turn the fryer off immediately and let the solution cool for a few minutes before resuming the process. To lessen the chance of boil over, turn the fryer’s gas
valve knob to the PILOT position occasionally.
or a portable filter unit. These units are not intended for this purpose, and will be
damaged by the solution.
shortening is heated to cooking temperature and may cause injury to nearby
personnel.

4.2 Boil-Out Procedure (cont.)
A. Pour cleaning solution into the frypot and add water to the bottom OIL LEVEL line scribed
in the back of the frypot.
above that of boiling water.
reset switch (if applicable). Turn the boil-out switch "ON".

least 5 minutes before lighting. D. The main burner will ignite.
E. When the solution nears boiling point, reset the temperature controller to 200° (93ºC).
F. The burners should shut off just as the water starts to boil.

left unattended. Press ON/OFF switch to the "OFF" position (Filtration/Boil-Mode equipped fryers) or reduce temperature (Operating Thermostat equipped fryers) to
G. The burners will heat the boil-out solution to a simmer. Simmer the solution for
approximately 45 minutes. Wearing protective gloves, scrub the sides of the frypot and the tubes with the L-shaped Teflon brush, being careful not to disturb the temperature sensing probes and the high-limit thermostat.
H. Do not allow the water level to decrease below the bottom OIL LEVEL line in frypot during
boil-out operation.

system. Irreversible damage will result if water is allowed into the system.
I. Operating Thermostat equipped fryers: After boil out is complete, turn the thermostat dial to "OFF". Filtration/Boil-Mode equipped fryers: After boil out is complete, turn the boil-out and fryer switches to "OFF". Drain the solution from the frypot. Place a metal stockpot of sufficient size to safely hold the entire contents of the frypot under the drain port to collect the water/boil-out solution. Do not allow water or boil-out solution to drain into the filter pan. The filter pump is not designed for water operation, and will be irreparably damaged (see warning statement above).


4.3 Final Preparation (cont.)
etc., until the shortening is melted. If you see smoke coming from the shortening while melting this way, shorten the "ON" cycle and lengthen the "OFF" cycle. Smoke indicates potential scorching of the shortening, which will shorten its useful life.
operate in the MELT CYCLE mode until the shortening reaches 180°F. It will then automatically switch to normal operation.
F. When the frypot is filled and the shortening is melted, carefully replace the crumb screen
over the heat tubes. Wear oil-proof insulated gloves to avoid the potential for burn injury when placing crumb screen in frypot.
G. Before starting operation, set the electronic thermostat/operating thermostat or program the
computer to the probable working temperature and wait for the temperature to stabilize.
For additional computer operational procedures, see computer manual that shipped with fryer.

5.1 Operating Instructions: Electronic Thermostat Controller Decathlon Series gas fryers come standard with an electronic thermostat controller, which incorporates a temperature-control circuit board, a potentiometer, and a temperature probe. The potentiometer knob is turned to the desired temperature setting, similar to a standard thermostat. Various switch options for the controller are available, based on fryer options at the time of order. Typical switch options are illustrated below.
Fryer Power Switch: Turns fryer on and off.
Drain Reset Switch (Optional): Resets drain safety switch after closing drain valve. Drain valve must be completely closed prior to resetting switch.
Boil-Out Switch (Optional): When "ON", this switch by- passes the melt-cycle and allows the water temperature to reach 196°F.
F
F N
FRYER
E R
E S
T
BOIL OUT
F F O
N O
7 Amp (115VAC) or 5 Amp (230VAC) Filter Reset Breaker (if equipped with filter system): Inline between the filter pump and the filter power switch. Ensure power is "OFF" before resetting or replacing.
Manual Filter Power Switch (if equipped with filter system): Connects/disconnects power to filter pump if primary system fails. Fryer power switch should be "OFF" when filter is in use.

Electronic thermostat controller with power switch and boil- out option.

5.1 Operating Instructions: Electronic Thermostat Controller (cont.) FRYER POWER SWITCH – This switch turns the fryer on and off. When the power switch is in the "ON" position, the indicator light will be lit when calling for heat. BOIL-OUT SWITCH (Optional) – When the boil-out switch is "ON", it will bypass the electronic thermostat melt-cycle, and allow the water temperature to reach approximately 196°F (91°C). DRAIN RESET SWITCH (Optional) – Resets drain safety switch after draining the fryer. Drain valve must be closed completely before resetting switch. MANUAL FILTER POWER SWITCH (if equipped with filter system) – Controls power to the filter pump in the event the primary system fails. Fryer Power Switch should be in "OFF" position when in use. FILTER RESET BREAKER (7 Amp Circuit Breaker- 120VAC or 5 Amp Circuit Breaker- 230VAC) – the breaker is inline between the filter switch and the pump. Ensure filter power is off prior to resetting or replacing. 5 AMP (115VAC) or 2 AMP (230VAC) FUSE – each fryer circuit is protected by a 5 amp (115VAC) or 2 amp (230VAC) fuse located under the control panel. 5.2 Electronic Thermostat Controller/Computer
Main Power Switch (optional): connects/disconnects primary power; double-lighted with center position "OFF". This switch controls two Electronic Thermostat controllers/Compu-Fry or remote computers and/or two back-up thermostats (optional).
Fryer Power Switch: controls power to each individual fryer, both in Electronic Thermostat or back-up mode.
ON OFF ON B
C O M P U T E R
POWER
ON OFF ON AC B
C O M P U T E R
T AC
T
F F
N
M K
OR
N
O
M K
OR
F
T U
F
MAIN POWER UP
T
BOIL OUT
MAIN POWER P
BOIL OUT
F O
O
F F O
N O
N F
High-Limit Reset Switch: located under each individual control panel. This switch must be manually reset if fryer exceeds high-limit setpoint.
Filter Reset Switch [7 Amp (115VAC) or 5 Amp (230VAC) Circuit Breaker]: this switch is inline between the filter pump and incoming line voltage. Ensure power is "OFF" before resetting or replacing.
Boil-Out Switch: operates only in "Electronic Thermostat" mode. When "ON", this switch bypasses the Electronic Thermostat melt-cycle and allows the water temperature to reach 196°F (91°C).

5.2 Electronic Thermostat Controller/Computer (cont.) MAIN POWER SWITCH – connects/disconnects primary power; double-lighted with center position "OFF". One main switch controls two electronic thermostats/Compu-Fry or remote computers. When the main power switch is in the center position, power is removed from the two fryers controlled by the electronic thermostats/Compu-Fry or remote computers. When the main power switch is pressed to the right, power is supplied to the electronic thermostat/Compu-Fry or remote computer of each fryer. INDIVIDUAL FRYER POWER SWITCH – this switch controls power to the individual fryer. When the power switch is in the "ON" position, the indicator light will be lighted when calling for heat. The power switch only removes power from the temperature control circuit (electronic thermostat controller). The power switch should be in the "OFF" position during filtering. BOIL-OUT SWITCH – operates only when the electronic thermostat controller is enabled. When the boil-out switch is "ON", it will bypass the melt cycle, and allow the water temperature to reach approximately 196°F (91°C). HIGH-LIMIT RESET – this reset button is located under each individual control panel, and must be manually reset if the fryer exceeds high-limit setpoint. FILTER RESET BREAKER (7 amp circuit breaker- 120VAC, or 5 amp circuit breaker- 230VAC) – the breaker is in line between the filter switch and the pump. Ensure filter power is off prior to resetting or replacing. 5 AMP (115VAC) or 2 AMP (230VAC) FUSE – each fryer circuit is protected by a 5 amp (115VAC) or 2 amp (230VAC) fuse located under the control panel.

operational procedures. 6.1 General Most SUFF/UFF systems use filter paper as the filter medium. Some filter systems can be special ordered with a filter-leaf assembly, which eliminates the need for filter paper. Both types require the use of filter powder to enhance the filtration process. Photos used in the procedural illustrations may or may not resemble the filter unit that came with the frying system. The following procedures apply to all fryers equipped with SUFF/UFF filter systems. Filter system design depends on the frying system configuration (single or multi-batteried systems- see photos below).





Typical Under Fryer Filter (UFF) installed in a multi-batteried frying system.
Typical Single Under Fryer Filter (SUFF) installed in a single fryer.

6.2 Filter Preparation On initial installation and before each use, clean the filter:
a. remove all loose parts from the filter,
b. wash the filter pan and all accessories in hot, soapy water,
c. and dry thoroughly. 6.2.1 Filter Unit Types FILTER PAPER AND HOLD DOWN RING Filter paper is held in place by a hold-down ring. Oil moves through the paper, leaving behind impurities.
A filter unit which utilizes disposable filter paper to filter oil.

6.2.1 Filter Unit Types (cont.) FILTER LEAF A filter leaf is a fine mesh screen which is reusable and takes the place of disposable paper. Oil moves through the leaf, leaving behind impurities.
5 A filter unit which utilizes a filter leaf to filter the oil.

6.2.2 Assembling the Filter FILTER PAPER AND HOLD DOWN RING 1. Place the support grid in the bottom of filter pan. 2. Put one filter paper sheet on top of the support grid. Be sure the paper covers the filter pan bottom and laps two inches onto the pan wall. 3. Position the hold-down ring on top of the filter paper. Ensure the hold-down ring seals around the support grid. This prevents air from getting into the system.

Support grid properly placed in filter pan.

Ensure filter paper overlaps two inches on all sides and is evenly distributed under the hold- down ring.

Hold-down ring positioned correctly over filter paper in filter pan.

6.2.2 Assembling the Filter (cont.) 4. Sprinkle 8 ounces (227g) of filter powder on the filter sheet. Ensure the powder covers the filter paper evenly. 5. Place the crumb screen in the filter pan. Allow the crumb screen to rest on the top edges of the hold-down ring. 6. Place filter pan cover onto the filter pan assembly. Ensure the pickup tube is properly positioned in the pan lid access hole.

Sprinkle the proper amount of filter powder evenly over the paper.

Crumb screen properly placed.





Fully assembled pan with pickup tube properly positioned in pan lid access hole. Position may vary between models.

6.2.2 Assembling the Filter (cont.) FILTER LEAF 1. Remove the filter pan from the fryer by pulling out on the filter pan handle. 2. Remove the filter pan lid picking it up off of the pan. 3. Remove the crumb basket by lifting it up and out of the filter pan. Be careful not to damage the tubes or connectors in the pan. 4. Remove the filter leaf by lifting up on the pickup tube and raising the filter leaf assembly gently out of the filter pan. 5. Clean the filter leaf assembly, crumb screen, and pan with warm soapy water. Thoroughly rinse and dry. 6. When it is clean, place the filter leaf carefully back into the filter pan.





Pull out on the handle to remove the filter pan.




Remove the crumb screen by lifting it up and out.
Carefully remove the filter leaf assembly.
handle

6.2.2 Assembling the Filter (cont.) 7. Sprinkle 8 ounces (227g) of filter powder on the filter leaf. Ensure the powder covers the mesh evenly. 8. Replace the crumb tray in the pan after filter powder application. 9. Replace the pan lid. Ensure the pickup tube is properly positioned in the pan lid access hole.

Applying filter powder to filter-leaf.
Crumb screen properly placed in filter pan.





Fully assembled pan with pickup tube properly positioned in pan lid access hole. Position may vary between models.

6.2.3 Installing the Filter 10. Slide the filter inside the fryer cabinet. Ensure the male-female pickup tubes are fully engaged. Ensure the filter pan opening is directly under the center dump tube.
6.3 Daily Filter Operation


The filter pan slides under the fryer (left), connecting with a male connector (right). Ensure that the pickup tube is securely coupled with this connector. Its location may vary based on model.




350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position prior to operating any switches or valves. Failure to do this can
result in severe burns.
operational procedures. 6.3.1 General Overview Only filter oil at operating temperature (~350°F/~177°C). When filtering begins, the filter motor engages and oil is drawn through filter paper or a filter-leaf assembly and pumped back into the frypot through oil return plumbing or an optional filter wand. The frypot’s drain remains open during the filtering process, allowing oil to filter through the frypot and back into the filter unit. Allow the oil to cycle through this process for approximately 5 minutes. At the end of 5 minutes, close the drain valve and allow the frypot to fill to the top OIL LEVEL line. Leave the pump running for 10-15 seconds after bubbles appear in the frypot or the optional wand sputters to ensure all oil is pumped from the drain pan and the lines. Close the oil return valve and, if an optional filter wand is used, press the wand toggle switch to OFF position.

6.3.2 Filtering Tools Assemble tools to be used for filtering. These are supplied with the filter starter kit included with the fryer/filter system:

6.4 Operating the Filter 6.4.1 Pan Preparation and Operation See Section 6.2.1, Assembling the Filter, and Section 6.2.2, Installing the Filter, for the appropriate filter preparation procedure. For optional filter hose and wand, see Section 6.4.3, Optional Filter Hose and Wand Operation.
at operating temperature (~350°F/ ~177°C). 1. Ensure the filter pan assembly is prepared as described in Section 6.2.1, Assembling the Filter, and ensure fryer is turned off. 2. Remove fry baskets from frypot and skim any large debris from the oil. Use extreme caution, as oil is at or near operating temperature (~350°F/~177°C). 3. Remove the support grid from the frypot using the clean-out rod. Stir the oil with the frypot/filter brush to suspend debris prior to draining.

Prior to filtering, skim any large debris from oil in frypot.

Removing support grid from fry vessel prior to filtering.

6.4.1 Pan Preparation and Operation (cont.) 4. After ensuring the filter pan is correctly positioned under the drain tubes, move the red handle to the open position (right) to drain the frypot into the filter pan. Drain ONLY one frypot at a time. The filter pan is designed to hold the contents of one frypot only. 5. After all oil has drained from the frypot into the filter pan, pull the yellow handle to open the oil return lines and activate the filter pump. Leave the red handle in the open position.

Move the red drain valve handle into the open position.

Pull the yellow handle to open the oil return valve and activate the filter pump.

6.4.2 Filter Operation 6. Oil will begin to pump from the filter pan into the frypot. If the frypot tubes, sides and bottom have sediment deposits, clean the frypot with the cleaning brush included with the fryer. Clean beneath and under the burner tubes, using care not to disturb the probes (arrow). 7. Allow the oil to circulate for approximately 5 minutes (process known as "polishing") to remove suspended particles. 8. After the filter cycle is complete, close the drain valve (push the red handle to the left until it stops) and allow the fryer to refill (see Step 4 above for additional reference).

Clean all sediment and suspended particles from the burner tubes and frypot as the oil begins to circulate. Use care not to disturb the probes (arrow) on the burner tube.

Polishing the oil removes suspended particles, which increases the life of the oil.

After filtering is complete, close the red drain handle to start refilling the frypot.

6.4.2 Filter Operation (cont.) 9. After all oil is pumped back into the frypot, bubbles will form, indicating air in the oil return lines. Allow the oil to bubble for 10- 15 seconds to ensure all oil is evacuated from the return lines. Push the yellow handle to close the oil return valve and deactivate the filter pump (see Step 5 above for additional reference). 10. If the oil level is low, add oil until the level is at the top OIL LEVEL line.

Allow the oil to bubble for 10-15 seconds to ensure evacuation of all oil in the return lines.

DO NOT OVERFILL THE FYPOT. This will cause oil to splash out of the frypot during cooking and may cause burns or damage. 11. Replace the frypot grid, using care not to splash hot oil. Turn the fryer on.
Add oil/shortening until the oil level is at the top OIL LEVEL line. DO NOT OVERFILL THE FRYPOT.
Replace the frypot grid, using care not to splash hot oil.

DECATHLON SERIES GAS FRYERS CHAPTER 5: UNDER FRYER FILTER (SUFF/UFF) FILTRATION
6.4.2 Filter Operation (cont.) 12. Do not allow crumbs to accumulate in the crumb tray. The crumb tray MUST be emptied into a fireproof container at the end of frying operations EACH DAY (see DANGER statement below).

Empty the filter pan crumb tray into a fire-proof container at the end of frying operations each day. DO NOT ALLOW CRUMBS TO ACCUMULATE IN TRAY.
can spontaneously combust if left soaking in certain shortening material.
a tight fit and should only be removed for cleaning.

6.4.3 Optional Filter Hose and Wand Operation Some frying systems come equipped with an optional filter hose, wand, and toggle switch to facilitate the removal of debris from the frypot. The hose attaches to a no quick-disconnect on the bottom front of the fryer and is controlled using a toggle switch on the fryer control panel. 1. Ensure the oil is at operating temperature (~350°F/~177°C). Turn the fryer off and open the fryer drain valve. Allow the oil to drain into the filter pan. 2. When all the oil has drained from the frypot, connect the hose/wand assembly to the quick- disconnect on the front bottom of the fryer cabinet. Ensure the hose is properly connected before proceeding. 3. Place the wand into the open frypot and activate the filter with the wand/disposal switch (rocker switch) on the front of the cabinet.



Moving the red drain valve handle to open the drain valve, allowing hot oil to drain into the filter pan.
Optional hose/wand disconnect properly connected to disconnect valve in fryer cabinet.
After the wand end is properly positioned inside the appropriate frypot, activate the filter pump with the wand/ disposal switch located on the front of the fryer.

DO NOT PROCEED UNLESS THE WAND IS INSIDE THE FRYPOT. Hot oil can immediately flow from the wand when it is attached, causing burns if the wand is not in the frypot.


6.4.3 Hose and Wand Operation (cont.) 4. The oil will start to flow immediately into the frypot. Keep the wand inside the frypot at all times while the filter pump is activated. 5. Rinse debris from the frypot into the filter pan with the wand. When cleanup is complete, close the drain valve (red handle) and press the wand/disposal switch to OFF. Allow hose/wand to drain into the filter pan. 6. Disconnect the hose/wand from the fryer. 6.5 Complete Filtering 1. Refill the frypot by pulling the yellow handle to open the oil-return valve (this activates the filter pump automatically). 2. After the frypot refills, allow the oil to bubble for 10-15 seconds to ensure evacuation of all oil from the oil return lines. Push in the yellow handle to close the oil-return valve and de-activate the filter pump. Filtration is complete. Filter another frypot or return the fryer to operation.

The red handle is attached to the drain valve. The yellow handle is attached to the oil return valve.

Use the optional wand to rinse debris from the frypot into the filter pan. Maintain a firm grip on the wand handle at all times.

Return filtered oil to the frypot by pulling yellow handle to open oil return valve.
Yellow · Red


cooking temperature, it will cause spattering of the oil/shortening, which can result
Any equipment works better and lasts longer when maintained properly and kept clean. Cooking equipment is no exception. The Decathlon Series gas fryer should be kept clean during the working day, and thoroughly cleaned at the end of each day. Below are recommendations for daily, weekly and periodic preventative maintenance.

contact surfaces. Read the directions and precautionary statements for use. Particular attention must be paid to the concentration of cleaner and the length of
A. Remove and wash all removable parts.
B. Clean all exterior surfaces of the cabinet. Do not use cleaners, steel wool, or any other
abrasive material on stainless steel.
C. Filter the cooking oil and replace if necessary. The oil should be filtered more frequently
when under heavy use. 7.2 Weekly
A. Completely drain the oil from the fryer into a metal stockpot of sufficient size to safely hold
the entire contents of the frypot for disposal. Do not use a glass or plastic container.
B. Clean the frypot by following boil-out procedures in Chapter 4.2.

result.

burns. All stainless steel fryer cabinet parts should be wiped regularly with hot, soapy water during the day, and with a liquid cleanser designed for stainless steel at the end of each day.
A. Do not use steel wool, abrasive cloths, cleansers or powders.
B. Do not use a metal knife, spatula or any other metal tool to scrape stainless steel! Scratches
are almost impossible to remove.
C. If it is necessary to scrape the stainless steel to remove any encrusted materials, soak the area
first to soften the deposit, then use a wood or nylon scraper only.

tests are required. Use extreme care when performing such tests.
This appliance may have more than one electrical power supply connection point.
Disconnect all power cords before servicing.
Inspection, testing and repair of electrical components should be performed by an
authorized service agent only. The problems and possible solutions covered are those most commonly encountered. To troubleshoot, perform the test set-up at the beginning of each condition. Follow each step in sequence. 8.1 Pilot Burner Malfunction
A. Pilot will not ignite; no evidence of gas at pilot burner.
B. Pilot burner ignites but will not remain lit when gas valve manual knob is released.

8.1 Pilot Burner Malfunction (cont.)
C. Pilot flame of proper size, but is unstable. Flame wavers and does not envelope the
thermocouple completely at all times.
Check for drafts that might be caused by air conditioning equipment or make-up air
apparatus. Turn air-moving equipment off and recheck the pilot. 8.2 Main Burner Malfunctions
A. Main burner will not come "ON"; gas not detected at main burner.
B. Main burner flames are small and appear lazy; shortening does not come up to temperature
quickly.
C. Signs of excessive temperature; shortening scorches and quickly becomes discolored.

8.2 Main Burner Malfunctions (cont.)
D. Fryer will not reach the temperature setting and/or runs erratically.
E. Fryer shortening temperature cannot be controlled; fryer runs at high-limit temperature.
1. Defective operating thermostat or temperature probe; Call Authorized Service Agent. 8.3 Electronic Thermostat Controller Calibration The electronic thermostat controller maintains a specific cooking temperature through a sensing probe mounted in the frypot. If the actual temperature of the shortening varies from the controller dial setting, loosen the knob setscrew and rotate the knob until it agrees with that of the actual shortening temperature. When obtaining actual shortening temperature, ensure that the thermometer is inserted within 1 inch of the frypot-mounted probe. If proper calibration cannot be achieved, contact Authorized Service Agent for repair.


Control knob setscrew location (arrow – counter- set in knob).
Electronic thermostat probe in frypot (arrow).






Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 FAX (Tech Support) 1-318-219-7135
PRINTED IN THE UNITED STATES
1-800-551-8633 819-5698 MAY 2007