Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633 APRIL 2008

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.

DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all times when the fryer is in use.
DANGER This product contains chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.

1.1 Applicability and Validity The Protector® Series Gas Fryer with SMART4U® technology has been approved by the European Union for sale and installation in the following EU countries: AT, BE, DE, DK, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE. This manual is applicable to and valid for all Protector® Series Gas Fryers sold in English- speaking countries, including those in the European Union. Where conflicts exist between in- structions and information in this manual and local or national codes of the country in which the equipment is installed, installation and operation shall comply with those codes. This appliance is only for professional use and shall be used by qualified personnel only, as defined in Section 1.7.
1.2 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones that follow.
in a malfunction of your system.
in damage to your system, and which may cause your system to malfunction.
in injury to personnel, and which may cause damage to your system and/or cause your
system to malfunction. Your fryer is equipped with automatic safety features: 1. High temperature detection shuts off gas to the burner assembly should the controlling thermostat fail. 2. An optional safety switch built into the drain valve prevents burner ignition with the drain valve even partially open.

1.3 Computer Information for the CM7 Computers
FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device, pur- suant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harm- ful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The user is cautioned that any changes or modifications not expressly approved by the party respon- sible for compliance could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions.
The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
1.4 European Community (CE) Specific Information
The European Community (CE) has established certain specific standards regarding equipment of this type. Whenever a conflict exists between CE and non-CE standards, the information or instructions concerned are identified by means of shadowed boxes similar to the one below.
6" W.C. 14" W.C.
Natural 1.49 kPa 3.49 kPa
14.68 mbar 34.72 mbar
11" W.C. 14" W.C.
LP 2.74 kPa 3.49 kPa
27.28 mbar 34.84 mbar
Type Minimum Maximum

1.5 Equipment Description Protector® Series high-efficiency gas fryers employ a unique infrared burner system that uses up to 43% less energy to cook the same volume as conventional open-burner fryers. Models in this series include FPGL30 variants. FPGL30 models have a built-in FootPrint Pro filtration system located under the leftmost two fryers in a battery. All Protector® Series Gas fryers are of an open-frypot design with no tubes and have a hand-sized opening into the cold zone, which makes cleaning the stainless frypot quick and easy. Heating is supplied by a pair of infrared burner assemblies mounted on each side of the frypot. Combustion air for the burners is supplied by a dedicated blower mounted on the front of the frypot. Protector® Series Gas fryers can be configured for natural gas, propane (LP), or manufactured gas, as required by the customer. Each frypot is equipped with a temperature probe for precise temperature control.
All Protector® Series Gas fryers come standard with electronic ignition, melt cycle and boil-out mode. The Protector® Series Gas fryers are controlled with a CM-7 computer. Fryers in this series come in full pot arrangements, and can be purchased as two, three or four vat fryers. All fryers in this series require an external source of AC electrical power. Units can be configured for voltages ranging from 100 VAC to 240 VAC. FPGL30 fryers are shipped completely assembled. All fryers are shipped with a package of standard accessories. Each fryer is adjusted, tested, and inspected at the factory before crating for shipment. 1.6 Installation, Operating, and Service Personnel
Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.7. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7. 1.7 Definitions
Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.

QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in person or through a representative, are engaged in and are responsible for the installation of gas- fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qualified service personnel are those who are familiar with Frymaster equipment and who have been authorized by Frymaster, L.L.C. to perform service on the equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a minimum amount of parts for Frymaster equipment. A list of Frymaster Factory Authorized Service Centers (FASC) is included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Frymaster warranty on your equipment. 1.8 Shipping Damage Claim Procedure
Your Frymaster equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsibility for safe delivery upon its acceptance of the equipment for transport. What to do if your equipment arrives damaged:
Frymaster DOES NOT ASSUME RESPONSIBILITY FOR DAMAGE OR LOSS
INCURRED IN TRANSIT. 1.9 Parts Ordering and Service Information
In order to assist you quickly, the Frymaster Factory Authorized Service Center (FASC) or Service Department representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the fryer door. Part numbers are found in the Service and Parts Manual. Parts orders may be placed directly with your local FASC or distributor. Included with fryers when shipped from the factory is a list of Frymaster FASCs. If you do not have access to this list, contact the Frymaster Service Department at 1-800-551-8633 or 1- 318-865-1711 or by e-mail: service@frymaster.com.

When ordering parts, the following information is required:
Model Number: Serial Number: Type of Gas or Voltage: Item Part Number: Quantity Needed: Service information may be obtained by contacting your local FASC/Distributor. Service may also be obtained by calling the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711 or by e-mail: service@frymaster.com. When requesting service, please have the following information ready:
Model Number: Serial Number: Type of Gas: In addition to the model number, serial number, and type of gas, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem.
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.

2.1 General Installation Requirements Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7 of this manual, should perform all installation and service on Frymaster equipment. Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.7 of this manual. Failure to use qualified, licensed, and/or authorized installation or service personnel (as de- fined in Section 1.7 of this manual) to install, convert to another gas type or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel. Where conflicts exist between instructions and information in this manual and local or na- tional codes or regulations, installation and operation shall comply with the codes or regula- tions in force in the country in which the equipment is installed.
DANGER Frymaster appliances equipped with legs are for stationary installations. Appliances fitted with legs must be lifted during movement to avoid damage to the appliance and bodily injury. For movable installations, optional equipment casters must be used. Questions? Call 1-800-551-8633. 2.1.1 Clearance and Ventilation The fryer(s) must be installed with a 6” (150 mm) clearance at both sides and back when installed adjacent to combustible construction; no clearance is required when installed adjacent to noncombustible construction. A minimum of 24” (600 mm) clearance should be provided at the front of the fryer.

DANGER No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633. One of the most important considerations of efficient fryer operation is ventilation. Make sure the fryer is installed so that products of combustion are removed efficiently, and that the kitchen ventilation system does not produce drafts that interfere with burner operation. The fryer flue opening must not be placed close to the intake of the exhaust fan, and the fryer must never have its flue extended in a “chimney” fashion. An extended flue will change the combustion characteristics of the fryer, causing longer recovery time. It also frequently causes delayed ignition. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear must be kept clear and unobstructed.
DANGER This appliance must be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to the health of personnel in the room in which it is installed. Fryers must be installed in an area with an adequate air supply and adequate ventilation. Adequate distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank. Filters should be installed at an angle of 45º. Place a drip tray beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96 states, “A minimum distance of 18 in. (450 mm) should be maintained between the flue outlet and the lower edge of the grease filter.” Frymaster recommends that the minimum distance be 24 in. (600 mm) from the flue outlet to the bottom edge of the filter when the appliance consumes more than 120,000 BTU per hour. For installations in the United States, information on construction and installation of ventilating hoods can be found in the NFPA standard cited above. A copy of the standard may be obtained from the National Fire Protection Association, Battery March Park, Quincy, MA 02269. 2.1.2 National Code Requirements The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped “NAT” only to natural gas, those stamped “PRO” only to propane gas, and those stamped “MFG” only to manufactured gas. Installation shall be made with a gas connector that complies with national and local codes, and, where applicable, CE codes. Quick-disconnect devices, if used, shall likewise comply with national, local, and, if applicable, CE codes. In the absence of local codes, installation must conform to the national Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas and Propane Installation code, CSA B149.1, as applicable including: 1. The appliance and its individual shutoff valve must be disconnected form the gas supply piping system during any pressure testing of the system at test pressures in excess of ½ psi (3.5 kPa).

2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa). 2.1.3 Electrical Grounding Requirements All electrically operated appliances must be grounded in accordance with all applicable national and local codes, and, where applicable, CE codes. In the absence of local codes, the appliance must be grounded in accordance with National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. All units (cord connected or permanently connected) should be connected to a grounded power supply system. A wiring diagram is located on the inside of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.

2.2 Caster/Leg Installation


After the fryer has been positioned under the exhaust hood, ensure the following has been accomplished: 1. Adequate means must be provided to limit the movement of fryers without depending upon the gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all times when the fryer is in use. The restraining cable and installation instructions are packed with the flexible hose in the accessories box that was shipped with your unit.

2. Level fryers equipped with legs by screwing out the legs approximately 1 inch then adjusting them so that the fryer is level and at the proper height in the exhaust hood. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the hood be 24 in. (600 mm) when the appliance consumes more than 120,000 BTU per hour. NOTE: There are no built-in leveling devices on fryers equipped with casters. The floor where the fryer is to be installed must be level. 3. Test the fryer electrical system:
a. Plug the fryer electrical cord(s) into a grounded electrical receptacle.
b. Place the power switch in the ON position. Verify that the display indicates CYCL. c. Place the fryer power switch in the OFF position. Verify that the display indicates OFF. 4. Refer to the data plate on the inside of the fryer door to determine if the fryer burner is configured for the proper type of gas before connecting the fryer quick-disconnect device or piping from the gas supply line. 5. Verify the minimum and maximum gas supply pressures for the type of gas to be used in accordance with the accompanying tables.


2.4 Connection to Gas Line
Never use matches, candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply to the appliance at the main shut-off valve and immediately contact the local gas company or an authorized service agency for service. The size of the gas line used for installation is very important. If the line is too small, the gas pressure at the burner manifold will be low. This may cause slow recovery and delayed ignition. The incoming gas supply line should be a minimum of 1½” (38 mm) in diameter. Refer to the chart below for the minimum sizes of connection piping.

Gas Connection Pipe Sizes (Minimum incoming pipe size should be 1 1/2" (41 mm))
Gas Single Unit 2 - 3 Units 4 or more units*
Natural 3/4" (22 mm) 1" (28 mm) 1 1/4" (36 mm)
Propane 1/2" (15 mm) 3/4" (22 mm) 1" (28 mm)
Manufactured 1" (28 mm) 1 1/4" (36 mm) 1 1/2" (41 mm)

* For distances of more than 20 feet (6 m) and/or more than 4 fittings or elbows, increase the connection by one pipe size. The Protector® Series gas fryer has received the CE mark for the countries and gas categories indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU and category 3P/B, which is 23kW.
CE Approved Gas Categories by Country
COUNTRIES CATEGORIES GAS PRESSURE (MBAR) G20 20 AUSTRIA (AT) II2H3B/P G30, G31 50 I2E(R)B G20, G25 20, 25 BELGIUM (BE) I3+ G30, G31 28-30, 37 G20 20 DENMARK (DK) II2H3B/P G30, G31 30 G20, G25 20, 25 II2Esi3+ G30, G31 28-30, 37 G20, G25 20, 25 FRANCE (FR)
II2Esi3P G31 50 G20 20 FINLAND (FI) II2H3B/P G30, G31 30 G20, G25 20 II2ELL3B/P G30, G31 50 GERMANY (DE)
I3P G31 50 G20 20 GREECE (GR) II2H3+ G30, G31 28-30, 37 G20 20 ITALY (IT) II2H3+ G30, G31 28-30, 37 G20 20 IRELAND (IE) II2H3+ G30, G31 28-30, 37 G20 20 LUXEMBOURG (LU) II2E3B/P G30, G31 50 G25 25 II2L3P G31 50 G25 25 NETHERLANDS (NL)
II2L3B/P G30, G31 30 NORWAY (NO) I3B/P G30, G31 30 G20 20 PORTUGAL (PT) II2H3+ G30, G31 28-30, 37 G20 20 II2H3+ G30, G31 28-30, 37 G20 20 SPAIN (ES)
II2H3P G31 37, 50 G20 20 SWEDEN (SE) II2H3B/P G30, G31 30 G20 20 UNITED KINGDOM (UK) II2H3+ G30, G31 28-30, 37

CE Standard Required airflow for the combustion air supply is 2m3/h per kW.

When using thread compound, use very small amounts on male threads only. Use a pipe thread compound that is not affected by the chemical action of LP gases (Loctite™ PST56765 Sealant is one such compound). DO NOT apply compound to the first two threads. Doing so may allow some of the compound to enter the gas stream, resulting in clogging of burner orifices and/or the control valve. 2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A soap solution should be used for this purpose. 3. Close the fryer drain valve and fill the frypot with water and boil-out solution to the bottom OIL LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are described in the “Lighting Instructions” and “Boiling Out the Frypot” topics found in Chapter 3 of this manual.


CE Standard Burner Manifold Gas Pressures for Fryers Manufactured After April 1999
Vat Natural Gas Lacq (G20) under 20 mbar 7 7
Natural Gas Groningue * (G25) under 25 mbar 10 10
Natural Gas Groningue (G25) under 20 mbar 10 10
Butane (G30) at 28/30 or 50 mbar 17 17
Propane (G31) under 37 or 50 mbar 20 20
* Belgian G25 = 7,0 mbar (single or dual)

2.5 Converting to another Gas Type
DANGER This appliance was configured at the factory for a specific type of gas. Converting from one type of gas to another requires the installation of specific gas-conversion compo- nents. Conversion instructions are included with conversion kits. Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.7 of this manual.
Protector® Series gas fryers manufactured for non-CE countries use different burners for each type gas. The burners in fryers built for Propane gas have a special gray-colored coating on the burner tiles to enable them to withstand the higher caloric value of the Propane gas. Burners designed for use in propane units may be used in natural gas applications, but not vice versa.

Non-CE Gas Conversion Kits Natural Gas to Propane (LP) Gas Propane (LP) Gas to Natural Gas Full Vat: Part Number 826-2527 Full Vat: Part Number 826-2528 Dual Vat: Part Number 826-2529 Dual Vat: Part Number 826-2530
Units manufactured for export to CE countries are equipped with “universal” burners that may be used with either Natural (G20, G25) gas or Butane (G30) and Propane (G31) gasses.
CE Gas Conversion Kits for Units with Gas Valve 810-1715 G20 or G25 (Natural) to G30 or G31 Gas: G30 or G31 to G20 or G25 (Natural) Gas: Part Number 826-1196 Part Number 826-1197
CE GAS CONVERSION INSTRUCTIONS 1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice. 2. Between a 2nd family (G20 or G25) and a 3rd family gas (G30 Butane or G31 Propane): a. Change the orifices. b. Adjust the manifold pressure. 3. Remove the old rating plate and return to Frymaster. Affix the new rating plate included with the conversion kit in place of the old rating plate stating the gas has been converted. 4. If the destination language changes, replace the rating plate. Call your local service agency or KES for a label kit. The language of reference will be on the corner of the label.

2.6 Positioning the Fryer
To level fryers, adjust the casters being careful to ensure the fryer(s) are at the proper height in the frying station. When the fryer is leveled in its final position, install the restraints provided by the KES to limit its movement so that it does not depend on or transmit stress to the connection. Install the re- straints in accordance with the provided instructions. If the restraints are disconnected for service or other reasons, they must be reconnected before the fryer is used.


FINDING YOUR WAY AROUND THE PROTECTOR® SERIES GAS FRYER

3.1 Controller Operation and Programming Protector® Series gas fryers are equipped with CM-7 computers (illustrated below). Refer to the CM7 Computer Operating Instructions in Chapter 4 for the computer programming and operating procedures.
CM7 COMPUTER 3.2 Equipment Setup and Start-Up Procedures
Before lighting the fryer, make sure the fryer is OFF and the frypot drain valve(s) is/are closed. Remove the basket support rack(s), if installed, and fill the frypot to the bottom OIL-LEVEL line. 3.2.1 Setup


Placing the ON/OFF switch in the OFF position also turns off the gas valve. Wait five minutes before continuing with Step 2, which will also turn on the gas valve.
After placing the ON/OFF switch in the OFF position, turn the gas valve knob to the OFF position. Wait 5 minutes, then turn the knob to the ON postion and proceed with Step 2.
ON
OFF
OFF
2. Press the computer ON/OFF switch to the ON position and set the thermostat or program the computer for normal cooking temperature. 3. If the burners fail to light, press the ON/OFF switch to the OFF position and wait 60 seconds. Repeat step 2. 4. The fryer will automatically enter the melt cycle mode if the frypot temperature is below 180ºF (82ºC). (NOTE: During the melt cycle, the burners will repeatedly fire for a few seconds, then go out for a longer period.) When the frypot temperature reaches 180ºF (82ºC), the unit will automatically switch to the heating mode. The burners will remain lit until the frypot temperature reaches the programmed cooking temperature. 5. After the burners have been lit for at least 90 seconds, observe the flames through the burner viewing ports located on each side of the combustion air blower.


housings. The optimum burn is a bright orange-red glow. If a blue flame is observed, or if there are dark spots on a burner face, adjust the air gas mixture as follows: On the side of the blower housing opposite the motor is a plate with a locking nut. Loosen the nut enough to allow the plate to be moved, then adjust the position of the plate to open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position and tighten the locking nut.
3.3 Boiling Out the Frypot To ensure that the frypot is free of any contamination resulting from its manufacture, shipping, and handling during installation, the frypot must be boiled out before first use. Refer to page 4-16 for this procedure. 3.4 Shutting the Fryer Down
For short-term shut down during the workday, place the computer ON/OFF switch in the OFF position and put the frypot covers in place (if the fryer is so equipped). When shutting the fryers down at closing time, place the computer ON/OFF switch in the OFF position. Then place the gas valve in the off position. See illustration below.

Placing the ON/OFF switch in the OFF position also turns off the gas valve.
After placing the ON/OFF switch in the OFF position, turn the gas valve knob to the OFF position.
Put the frypot covers in place (if the fryer is so equipped).

3.5 Oil Attendant™ Automatic Top-Off
Oil is continually topped off in the frypots from a reservoir in the cabinet. The reservoir holds a 35 pound box of oil. In a typical operation this will last approximately two days before changing. Components of the system are annotated at the right (see Figure 1). NOTE: The system is intended to top off the frypots, not fill them. The frypots will require manual filling upon startup and after boil out.
3.5.1 Prepare the System for Use To prepare the system for its initial operation, remove the cross brace (see Figure 2). Do not replace the screws. Do not remove cross brace before fryer is in its final position. Install the JIB basket shipped in the accessories pack. Follow these instructions to prepare the cabinet for the installation of the first box of oil and subsequent boxes of oil.


Figure 2 Figure 3
3.5.2 Install the Oil Reservoir Remove the original lid from the oil container and foil liner. Replace with the provided cap, which has connected suction hardware. Ensure the feeder tube from the cap reaches to the bottom of the oil con- tainer. Place the oil container inside the cabinet and slide it into place (as shown on the following page). Avoid catching the suction hardware on the cabinet interior as the container is placed in the fryer. The system is now ready for operation. As the fryer heats to preprogrammed temperatures, the system will energize and then slowly add oil to the frypot as needed, until the oil reaches an optimal level. 3.5.3 Routine Oil Changes When the oil reservoir level is low, the Oil Butler®, a yellow LED, is activated (see Figure 4). Once the reservoir is refilled and/or replaced, pressing the reset button above the JIB turns the LED off.







Programming, Temp, Unlock and Navigation Buttons
Cook Cycle and Selection Buttons
ON/OFF
4.1 CM7 General Information Welcome to the CM7, a computer that has one-button cooking and the utility of 40-product menu capability. The computer is easy to use. One button push starts a cook cycle for an item cooked in a dedicated vat. The same flexible computer on a multi-product vat requires only two button pushes to launch a cook cycle. Just choose a menu item on a product buttons and press, and then press a cook cycle button under the display showing the desired item. The computer can move seamlessly from Chicken Strips to Crispy Chicken to any added menu item. In dedicated mode, the CM7 will display FR FRIES (shown above) and will launch a cook cycle with one push of a cook channel button. In multi-product mode (shown right), the LED display shows dashed lines. To launch a cook cycle, press a product button and then press the cook cycle button that corresponds with the location of the dropped basket. By pressing the product button for Chicken Strips, CHK STRP appears in the display. Just press the cook cycle button corresponding to the location of the appropriate dropped basket.

Pressing assigned product buttons displays products.
Pressing either cook cycle button under the CHK STRP displays launches a cook cycle.
Heat Indicator Lamp · Product Buttons



FR FRIES FR FRIES
A menu item, such as FR FRIES shows in display 1
H1 is displayed and alternates with FRIS. As the quality time counts down.
Press a cook channel button to begin the cook cycle.
Pressing the cook channel button now will launch a cook cycle and end the quality countdown.
Display alternates between abbreviated product name and remaining cook time.
Hold is displayed when the quality time has elapsed.
Shak is displayed when it is time to shake the fry basket.
Pressing the cook channel button restores the display to FR FRIES and the unit is ready for cooking.
Press cook channel button to cancel alarm.
Cook is displayed when the cook cycle is complete.
1 Press cook channel button to cancel alarm.



4.7 CM7 Button Description and Functions 4.7.1 Navigation Buttons The menu on the CM7 uses 34and tu buttons to navigate the various menus and submenus (see Figure 1).

When programming, the left screen shows a menu or submenu item. The right screen is for data entry. Data is entered with alpha-numeric characters, scrolling through lists or by toggling between choices.
During programming, if a button is not pushed within one minute, the computer returns to operation mode. 4.7.2 Temperature and Unlock Buttons The TEMP button (see Figure 1), if pressed once while the fryer is on, displays current vat temperature on both sides. If the TEMP button is pressed twice, it shows the setpoint temperatures of the vats. If the fryer is off, the display shows the current versions of software. The UNLOCK button (see Figure 1), if pressed once while the fryer is on, shows the recovery time for each vat from the last test. Recovery displays the time required for the fryer to raise the temperature of the oil 50°F (28°C) between 250°F (121°C) and 300°F (149°C). Maximum recovery time should not exceed 1:40 for electric or 2:25 for gas. If the fryer is off, pressing the unlock button once allows access to Program Mode; pressing twice allows access to Manager Mode and pressing three times allows access to Tech Mode.
4.7.3 Cook Cycle and Selection Buttons The 9 and 8 buttons are dual-function buttons shared with the number 1 and 2 buttons. They are located directly below the LED displays (see Figure 2). Use these buttons to select or cancel functions. The 8 button is used to back out of submenus.

4.7.4 Melt Cycle and Cooking Displays Once the computer is switched on, it displays CYCL during melt cycle until the oil reaches 180°F (82°C). The display changes to LOW TEMP until setpoint is reached. Once setpoint is reached, the computer will display dashed lines or the product name

4.8 CM7 Menu Summary Tree Reflected below are the major programming sections in the CM7 and the order in which submenu headings will be found under the sections in the Installation and Operation Manual. Adding New Product Menu Items See section 4.10.2 Storing Product Menu Items in Product Buttons See section 4.10.3 Temperature Conversion from F° to C° See section 4.10.4

4.9 Setup Mode Programming The computer, upon initial power up or when accessed from Tech Mode, enters setup mode. These parameters need to be set to allow the computers functions to operate correctly. The setup sets the time, date, date format, language, fryer type, vat type, oil system type and the temperature format. These settings should only be changed by a technician. On initial power up the computer displays OFF
Figure 3 Figure 4
The computer displays CODE.
(7378) Figure 6 The computer displays FRYER SETUP changing to TIME FORMAT.
Computer displays time format with format on the right.
The computer displays ENTER TIME on the left and hh:MM on the right.
Example: 7:30 AM is entered 0730 if using the 12 hour format. 2:30 is entered 1430 if using 24 hour format. 7. Enter time in hours and minutes using the number buttons 0-9 (see Figure 10).


The computer displays ENTER TIME on the left and AM on the right if 12 hours system is chosen.
The computer displays DATE FORMAT on the left and US on the right.
The computer displays enter date on the left and MM-DD-YY or DD-MM-YY on the right.
Example: US Format – Mar. 15, 2007 is entered as 031507. International Format – 15 Mar. 2007 is entered as 150307) 12. Enter the date using the number buttons 0-9 (see Figure 15).
Figure 15 13. With the desired selection displayed, press the 9 (1) button (see Figure 16).
The computer displays LANGUAGE on the left and ENGLISH on the right.
The computer displays fryer type on the left and Elec on the right.

The computer displays VAT type on the left and SPLIT on the right.
The computer displays Oil SYSTEM on the left and JIB on the right.
tanks that are connected to the fryer.
Figure 24 The computer displays TEMPERATURE on the left and F on the right.
Figure 26 The computer displays FRYER Setup for three seconds then off.

4.10 CM7 Common Tasks Covered in this section are common tasks used in stores: 1. Escaping out of a menu or sub-menu. 2. Adding new product items. 3. Storing menu items in product buttons. 4. Temperature conversion from F to C. 4.10.1 Escape Menu Items To escape from MENUS or SUB-MENUS, press the 8 (2) button (Figure 27).
Figure 27 4.10.2 Adding New Product Items to the Menu To add a new product to the menu: 1. With the computer OFF, enter Program mode by pressing the UNLOCK button once (see Figure 28).
The computer displays PROGRAM.
Figure 29 The computer displays ENTER Code and sounds an audible alert. 3. Enter 1650 (see Figure 30). 1
(1650) Figure 30 The computer displays program MODE changing to SETPOINT TEMPERATURE.
Computer displays TEMP on the left and a temperature on the right.

Figure 33 The computer displays Product selection.
Computer displays PRODUCT Selection changing to select product.
The left display displays NAME and the right display displays a product name (ex. PROD 1). The right display shows a blinking cursor alternating with a blinking letter under the first character. 11. Using the number keys, enter the first letter of the new product (see Figure 38). Press the key until the desired letter appears.
Figure 38 12. Press the 4 button to advance the cursor to the next display space (see Figure 39). Use the #0 key to insert a space. The 3button can be used to move the cursor back.
For example, to enter “WINGS”, press the #8 key two times until W appears in the display. Then use the 4 button to advance the cursor to the next display space. Press the #3 key until I appears. Continue on until WINGS is spelled out on the display. Use no more than eight letters.
Figure 40 14. With cook time displayed on the left and :00 or a previously entered cook time displayed on the right, use the number keys (see Figure 41) to enter the product cook time in minutes and seconds (ex. 3:00 as 300).

Figure 43 18. Use the number keys (see Figure 44) to enter the elapsed time in minutes and seconds, before a shake is required.
Figure 45 20. Use the number keys (see Figure 46) to enter the time in minutes and seconds the product should be held before discarding. (ex. If the product requires discarding after 10 minutes, enter 1000).
Figure 47 22. Use the number keys (see Figure 48) to enter the number of cook cycles before the fryer prompts for filtration. (ex. If the product requires filtration after every six cook cycles, enter 6). NOTE: Setting the FILT AFTER to “0” will disable
filtration prompts.
Figure 49 Sensitivity is a built-in feature, which adjusts cooking time to compensate for the drop in frypot temperature when a product enters the oil. Different products vary in density, batch size, and temperature. Food products will also vary in cook time. A proper sensitivity setting will assure a high-quality product. Setting zero is the least sensitive and setting nine is the most sensitive. The default setting is 0. Some menu items may need an adjustment, depending on their cooking characteristics. A chart is provided on page 4-21 to assist in choosing a sensitivity setting. It is meant as a guide only and the settings may be changed to suit different needs. Use caution when changing sensitivity, as it could have an adverse affect on the products cooking cycles.


Figure 52 * Note: If additional programming, to add other products, is necessary press the 8 (2) button (see Figure 53) once and then the 4 button (see Figure 54) and return to step 8.
Figure 53 Figure 54
This function is used to store individual menu items in product buttons for one or two button cooking.
To store menu items to a specific button: 1. Perform steps 1-10 on pages 4-12 thru 4-13.

4.10.4 Temperature conversion from F° to C°. 1. With the computer OFF, enter Tech mode by pressing the UNLOCK button three times (see Figure 61). The computer displays TECH
(1658) Figure 63 4.11 Boil-Out Mode Before the fryer is first used, it should be boiled out to ensure that residue from the manufacturing process has been eliminated. Also, after the fryer has been in use for a period of time, a hard film of caramelized oil will form on the inside of the frypot. This deposit must be periodically removed to maintain your fryer’s efficiency.
1. Drain the frypot in accordance with Section 5.1 (page 5-1), but do not refill with cooking oil. 2. After draining the frypot, clean all food particles and residual oil from the frypot and filter pan (if so equipped). BE CAREFUL, this material may still cause severe burns if it comes in contact with bare skin. 3. Close the drain valve securely and fill the frypot with a solution of automatic dishwasher detergent (or commercially available boil-out solution) and cold water to the bottom OIL- LEVEL line.

Figure 64 6. Press the 9 (1) button (see Figure 65). The computer displays ENTER Code and sounds an audible alert.
Figure 65 7. Enter 1650 (see Figure 66). The computer displays program MODE changing to SETPOINT TEMPERATURE.
The computer displays strt boil, alternating with yes no. 11. Press the 9 (1 yes) button to start boil-out (see Figure 70). The computer displays boilOUT on both sides. The fryer heats to 195°F (91°C).


WARNING Do not drain boil-out solution into a shortening disposal unit (SDU), a built-in filtration unit, or a portable filter unit. These units are not intended for this purpose, and will be damaged by the solution. 15. Add two gallons (7.6 liters) of water. Drain out the solution and clean the frypot(s) thoroughly. 16. Refill the frypot(s) with clean water. Rinse the frypot(s) twice, drain and dry with a clean towel. Thoroughly remove all water from the frypot and elements before refilling the frypot with oil.

DANGER Ensure that the frypot is completely free of water before filling with oil. Failure to do so will cause splattering of hot liquid when the oil is heated to cooking temperature. 4.11.1 Clean Filter Pan, Detachable Parts and Accessories As with the frypot, a deposit of carbonized oil will accumulate on the filter pan and detachable parts and accessories such as baskets, sediment trays, or fish plates. Wipe the filter pan and all detachable parts and accessories with a clean cloth dampened with a detergent solution (or the parts can be run through a dishwasher). Rinse and thoroughly dry each part. DO NOT use steel wool or abrasive pads to clean these parts. The scratches that result from such scrubbing make subsequent cleanings more difficult.


4.12 Manager Mode 1. With the computer OFF, press the UNLOCK button twice (see Figure 71). The computer displays MANAGER and sounds an audible alert.
Figure 72 The computer displays ENTER Code and sounds an audible alert.
(4321) Figure 73 The E-LOG mode is used to view the ten most recent error codes encountered on the fryer. These codes are displayed from 1-10 with the most recent displayed first. The time, date and error code are displayed. 4. Press the 9 (1 ) button to accept selection (see Figure 81).
The alert tone mode allows a manager to adjust the volume to nine levels and the tone is adjustable to three frequencies. One of three audio frequencies may be chosen to distinguish fryers in kitchens with multiple fryers.

The computer displays volume 1-9 on the left and 1 on the right.

Figure 80 The computer displays tone 1-3 on the left and 1 on the right.

Product 350° F/176° C Sensitivity Setting Chicken chicken fillet, 1 ¼ oz. 3:25 5 chicken fillet (frozen), 4 oz. 4:20 5 chicken patty (frozen), 5 oz. 6:15 5 frozen chicken 5 fresh chicken, 9 pieces 5 Potatoes steak fries 3:43 5 regular fries, ½-inch 3:16 5 shoestrings, ¼-inch 1:50 5 shoestrings, 3/8-inch 2:40 5 tater tots 2:05 5 hash browns 2:05 5 farm fries 1:14 5 Seafood crab cakes 4:00 3 clam cakes 4:00 3 large scallops 3:25 3 small scallops 1:10 3 shrimp (35 to a lb.) 2:15 3 shrimp (40 to 75 to a lb.) 1:45 3 shrimp (75 to 100 to a lb.) 1:10 3 cod, 2 ½ oz. 3:25 7 flounder fillet, 7 oz. 4:35 3 flounder, whole, 10-12 oz. 6:25 3 cod fillet, 3 ½ oz. 4:35 7 perch, 5 oz. 4:30 3 haddock, 7 oz. 6:25 7 clams 2:00 3 oysters 1:10 4 strip clams (fresh) 0:35 4 strip clams (frozen) 0:45 4 Vegetables okra 4:30 4 eggplant 4:00 4 zucchini 3:00 4 mushrooms 3:45 4 onion rings (frozen) 3:00 4 cauliflower 1:45 4 Other corn dogs 4 chicken fried steak patty 5:00 5 Note: This chart is provided to assist in choosing a sensitivity setting. It is meant as a guide only and the settings may be changed to suit different needs.


DANGER Draining and filtering of cooking oil must be accomplished with care to avoid the possibility of a serious burn caused by careless handling. The oil to be filtered is at or near 350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position before operating any switches or valves. Wear all appropriate safety equipment when draining and filtering oil.
DANGER When draining oil into a disposal unit or portable filter unit, do not fill above the maximum fill line located on the container. Oil must be drained into the filter pan, SDU or another suitable METAL container. (For safe, convenient draining and disposal of used oil or shortening, Frymaster recommends using the Frymaster Shortening Disposal Unit (SDU). The SDU is available through your local distributor.) 1. Turn the fryer power switch to the OFF position. 2. Position a METAL container with a sealable cover under the drainpipe. The METAL container must be able to withstand the heat of the oil and hold hot liquids. If you intend to reuse the oil or shortening, Frymaster recommends that a Frymaster filter cone holder and filter cone be used when a filter machine is not available. If you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container. 3. Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food particles, use the Fryer’s Friend (poker-like tool) to clear the blockage.

DANGER DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty. 4. After draining the oil, clean all food particles and residual oil from the frypot. BE CAREFUL, this material may still cause severe burns if it comes in contact with bare skin. 5. Close the drain valve securely and fill the frypot with clean, filtered or fresh cooking oil to the bottom OIL-LEVEL line. 5.2 Preparing the Built-In Filtration System for Use The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in operation. The FootPrint Pro filtration system is available in three different configurations:

5.2.1 Preparation for Use with Filter Paper or Filter Pad 1. Pull the filter pan out from the cabinet and remove the crumb tray, hold-down ring, filter paper and filter screen. (See Figure 1) Clean all components with a solution of detergent and hot water, then dry thoroughly.
The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (SDU) to be positioned under the drain. If using an SDU built before January 2004 see instructions on page 5-8. 2. Inspect the filter pan connection fitting to ensure that both O-rings are in good condition. (See Figure 2) 3. Then in reverse order, place the metal filter screen in the center of the bottom of the pan, then lay a sheet of filter paper on top of the screen, overlapping on all sides. (See Figure 1) If using a filter pad, ensure the rough side of the pad is up and lay the pad over the screen, making sure that the pad is in between the embossed ridges of the filter pan. 4. Position the hold-down ring over the filter paper and lower the ring into the pan, allowing the paper to rest on the sides of the filter pan. (See Figure 3)

Inspect the filter connection fitting O-rings.



Figure 4 6. Replace the crumb tray in the filter pan, then push the filter pan back into the fryer, positioning it under the drain. 5.2.2 Preparation for Use with the Magnasol Filter Assembly 1. Pull the filter pan out from the cabinet and remove the crumb tray and Magnasol filter assembly (See Figure 5). Clean as directed in section 5.4.

The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (SDU) to be positioned under the drain. NOTE: Refer to Section 5.4 for instructions on how to disassemble and reassemble the Magnasol filter screen assembly. 2. Inspect the fitting on the bottom of the Magnasol filter assembly to ensure that the O-ring is present and in good condition. (See Figure 6) 3. Inspect the filter pan connection fitting to ensure that both O-rings are present and in good condition. (See Figure 7)

Inspect the filter screen O-ring.

Inspect the filter connection fitting O-rings.

Figure 8 2. Press the 9 (1) button to continue (see Figure 9).

DANGER NEVER attempt to drain cooking oil from the fryer with the burners lit! Doing so will cause irreparable damage to the frypot and may cause a flash fire. Doing so will also void the Frymaster warranty. 3. Ensure that the filter is prepared. See Sec. 5.2. 4. Make sure the oil is at operating temperature. 5. Drain the frypot into the filter pan by rotating the drain valve handle 90º (see Figure 10). If necessary, use the Fryer's Friend clean-out rod to clear the drain from inside the frypot.




Open drain valve by rotating 90º.





Pull filter handle forward to activate pump.
Figure 11 7. The filter pump draws the oil through the filter medium and circulates it back up to and through the frypot during a 5-minute process called polishing. Polishing cleans the oil by trapping solid particles in the filter medium.

Filter Pump Reset Switch



WARNING Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to seal the joint between the fry vessels. Banging fry baskets on the strip to dislodge shortening will distort the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for cleaning. 5.4 Disassembly and Reassembly of the Magnasol Filter Dissassembly 1. Grasp the frame with your thumbs on the handles at the corner of the assembly and pull outward in opposite directions to separate the frame at the corner. Continue to open the frame (it will pivot at the opposite corner) until the outer screens and grid can be removed from the frame.

the outer screens

1. Clean the two frame pieces, outer screens, and grid using a good quality degreaser and hot water from a spray nozzle. The groove in the seal frame pieces can be cleaned with the edge of a Scotch-Brite™ or similar cleaning pad. 2. At each scheduled boil-out, disassemble the leaf filter assembly and place in the frypot being boiled out. Follow the boil-out procedure in Section 4.11 page 4-16 of this manual. 3. Allow all filter assembly components to air dry or thoroughly dry with clean towels before reassembling. Reassembly 1. Place the two outer screens together and align their edges (see illustration below). 2. Insert the screens into one of the frame halves (it doesn’t matter which one). Ensure that the fitting in the bottom screen is on the opposite side of the frame from the handle. 3. Slip the grid between the screens, ensuring that the grid is centered between the edges of the screens. 4. Connect the other half of the frame at the corner opposite the handles and pivot the frame onto the free edges of the screen.
Steps 1 and 2 - Stack outer screens and insert edges into frame.
Cleaning · Handle

5.5 Draining and Disposing of Waste Oil When cooking oil is exhausted, drain the oil into an appropriate METAL container for transport to the disposal container. Frymaster recommends the use of the Frymaster Shortening Disposal Unit (SDU). NOTE: If using an SDU built before January 2004 the filter pan cover must be removed to allow the unit to be positioned beneath the drain. To remove the lid, lift up on the front edge and pull it straight out of the cabinet. Refer to the documentation furnished with your disposal unit for specific operating instructions. If a shortening disposal unit is not available, allow the oil to cool to 100°F (38°C), then drain the oil into a METAL stockpot or similar METAL container. When draining is finished, close the fryer drain valve securely.
If the fryer is fitted with the optional oil disposal, ensure the filter pan is clean and ready for filtering. DO NOT discharge oil through a dirty or incomplete filter pan.

6.2 DAILY CHECKS AND SERVICE 6.2.1 Inspect Fryer and Accessories for Damage Look for loose or frayed wires and cords, leaks, foreign material in frypot or inside cabinet, and any other indications that the fryer and accessories are not ready and safe for operation. 6.2.2 Clean Fryer Cabinet Inside and Out Clean inside the fryer cabinet with dry, clean cloth. Wipe all accessible metal surfaces and compo- nents to remove accumulations of oil and dust. Clean the outside of the fryer cabinet with a clean, damp cloth soaked with dishwashing detergent, removing oil, dust, and lint from the fryer cabinet. 6.2.3 Clean the Built-in Filtration System Daily


There are no periodic preventive maintenance checks and services required for your FootPrint Pro Filtration System other than daily cleaning of the filter pan with a solution of hot water and detergent. If you notice that the system is pumping slowly or not at all, verify that the filter pan screen is on the bottom of the filter pan, with the paper on top of the screen. (If the unit is equipped with a Magnasol filter screen rather than with the standard screen and paper system, verify that the O-ring on the bottom fitting of the screen in present and in good condition.) Verify that the two O-ring(s) on the fitting at the right front of the filter pan are present and in good condition. 6.3 WEEKLY CHECKS AND SERVICE 6.3.1 Drain and Clean Frypot
6.3.2 Boiling Out the Frypot After the fryer has been in use for a period of time, a hard film of caramelized oil will form on the inside of the frypot. This deposit must be periodically removed to maintain your fryer’s efficiency. See section 4.11 page 4-16 for instructions on boiling out the frypot. 6.4 MONTHLY CHECKS AND SERVICE 6.4.1 Check Computer Magic 7 Set Point Accuracy (This check applies only to units equipped with Computer Magic 7 Controllers.) 1. Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the fryer temperature-sensing probe. 2. When the computer display shows a series of four dashes “ ” with no dot between the first and second dashes (indicating that the frypot contents are within the cooking range), press the switch once to display the temperature of the cooking oil as sensed by the temperature probe. 3. Press the switch twice to display the set point. 4. Note the temperature on the thermometer or pyrometer. All three readings should be within ± 5ºF (2ºC) of each other. If not, contact a Factory Authorized Service Center for assistance.

6.5.1 Clean Combustion Air Blower Assembly 1. Disconnect the blower wiring harness and remove the four blower mounting nuts (see Figure 1 below).
Blower assembly mounting nuts

Remove these fasteners.
Wiring connection

Wrap the motor and wires
with plastic wrap or a
plastic bag.
Left Viewing Port is Behind
for clarity.)
The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the applicable table on page 2-7 and the burners display a bright orange-red glow. If a blue flame is observed, or if there are dark spots on a burner face, the air/gas mixture requires adjustment. On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open

or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position and tighten the locking nut(s).
TYPICAL BLOWER ASSEMBLY SOME CE BLOWER ASSEMBLIES MAY BE CONFIGURED THIS WAY 6.6 SEMI-ANNUAL CHECKS AND SERVICE
6.6.1 Clean Gas Valve Vent Tube

− Verify that filter pan cover is present and properly installed.
− With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify that the pump activates and that bubbles appear in the oil of the associated frypot.

− Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return microswitches. No air bubbles should be visible in any frypot. − Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to
350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all cooking oil to return to the frypot (indicated by bubbles in the oil). Return the oil return handle to the OFF position. The frypot should have refilled in no more than 2 minutes and 30 seconds.

7.1 Introduction
This chapter provides an easy reference guide to some of the common problems that may occur during the operation of your equipment. The troubleshooting guides that follow are intended to help you correct, or at least accurately diagnose, problems with your equipment. Although the chapter covers the most common problems reported, you may encounter problems that are not covered. In such instances, the Frymaster Technical Services staff will make every effort to help you identify and resolve the problem. When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through to the most complex. Most importantly, always try to establish a clear idea of why a problem has occurred. Part of your corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections while you’re at it. If a fuse continues to blow, find out why. Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system. If you are in doubt as to the proper action to take, do not hesitate to call the Frymaster Technical Service Department or your local Frymaster Factory Authorized Service Center for assistance. Before calling a servicer or the Frymaster HOTLINE (1-800-551-8633):

7.2 Troubleshooting Fryers 7.2.1 Computer and Heating Problems PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
A. Computer not turned on. A. Press the ON/OFF switch to turn
the computer on.
B. Verify that the fryer is plugged in
No display on the
B. No power to fryer.
and that the circuit breaker is not tripped.
computer.
C. Computer, wiring harness or other
C. Call FASC.
component has failed.
A. Drain valve not fully closed. A. Verify that the drain valve is fully
closed.
B. Gas valve is not turned on. B. Turn the gas valve knob to the ON position.
Fryer does not heat.
C. Verify that any in-line manual shut off and main cut-off is
Or Display shows HELP with alarm sounding. Heating indicator is on, but
C. Manual gas shut off valve closed.
open.
D. Verify that the quick-disconnect fitting on the flexible gas line is firmly connected to the fryer.
D. Improperly connected quick-
disconnect fitting on gas line.
E. Verify that combustion air blower is running. If not, call FASC for service. If combustion air blower is functional, clean and adjust per instructions in Chapter 6 of this manual. Fryer is operating
light.
E. Obstructed or failed combustion
air blower.
normally, but recovery is slow
when cooking. Or Fryer is slow coming out of melt
Dirty or obstructed combustion air blower.
Clean and adjust per instructions
in Chapter 6 of this manual.
cycle and displays HELP a short time
after coming out of
melt cycle.
A. Dirty or obstructed combustion air
A. Clean and adjust per instructions
blower.
in Chapter 6 of this manual.
normally, but produces a popping sound when burners
B. Dirty or obstructed gas valve vent
B. Clean per instructions in Chapter
tube (non-CE fryers only).
6 of this manual.
ignite. C. Malfunctioning combustion air
C. If blower is slow to come up to
blower.
speed, contact FASC for service.
burners will not · Fryer is operating

PROBLEM PROBABLE CAUSES CORRECTIVE ACTION Heat indicator is on
and blower is running, but burner
Blown fuse on interface board or ignition module. Replace fuse.
will not ignite.
7.2.2 Error Messages and Display Problems
Problem Probable Causes Corrective Action CM7 display is in wrong temperature scale (Fahrenheit or
Incorrect display option programmed. See page 4-16 for instructions.
Celsius).
CM 7 display shows
Verify that the drain valve is fully closed. If the problem continues call your FASC.
Open drain valve or problem with latching circuitry.
FAILURE.
This in an indication of a malfunction in the temperature control circuitry, including a failure of the high-limit thermostat. Shut the fryer down immediately and call your FASC. CM 7 display shows
Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).
hot-hi-1.
HIGH temp. Fryer temp is above setpoint. Ensure setpoint is set correctly. If problem persists call your FASC.
This display is normal when the fryer is first turned on and may appear for a short while if a large batch of frozen product is added to the frypot. If the display never goes out, the fryer is not heating. Shut the fryer down and call your FASC. CM7 display shows
Frypot temperature is between 180°F (82°C) and 315°F (157°C).
LOW TEMP.
Problem with the temperature measuring circuitry including the probe.
Shut the fryer down and call your FASC.
PROBE FAILURE.
Verify that the drain valves are fully closed. Using the ON/OFF switch, turn the computer OFF and then ON again. If this does not correct the problem, call your FASC.
Open drain valve, failed computer, failed transformer, open high-limit thermostat.
FAILURE.
Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).
Call your FASC.
CM 7 display shows
HOT-HI -1.
CM7 display shows · CM7 display shows · CM7 display shows

Problem Probable Causes Corrective Action Heat indicator off upon initial startup. Display shows hi or
Failed computer, damaged wiring harness or connector. Call your FASC.
sounding.
Turn the computer OFF and then ON again. If problem persists, contact your FASC. 7.2.3 Filtration Problems
Computer locks up. Computer error.
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION A. Power cord is not plugged in or
A. Verify that the power cord is fully
circuit breaker is tripped.
plugged in. Is so, verify that circuit breaker is not tripped.
B. If the motor is too hot to touch
for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch. C. Failed filter handle microswitch.
B. Pump motor has overheated
causing the thermal overload switch to trip.
C. If the switch is loose, tighten the
nuts and bolts holding it in place, ensuring that when the handle is placed in the ON position, the lever on the microswitch is pressed firmly against the switch.
Test: If this is a multi-pot fryer, attempt to operate the pump using a different handle. If the pump starts, the handle microswitch is either out of alignment or has failed. When the handle is placed in the ON position, the lever on the microswitch should be firmly pressed against the switch. If so, the switch has failed. If not, the switch is loose and/or misaligned.
start.
If the switch has failed, call FASC.
filtering.
D. Filter pump blockage.
D. Pump blockages are usually
caused by sediment build-up in the pump due to improperly sized or installed filter paper and failure to use the crumb screen. Call FASC.
Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If the pump motor hums for a short time then stops, the probable cause is blockage of the pump itself.
hot with alarm · Filter Pump won’t · Pump stops during

A. Paper/screen needs changed or
cleaned. B. If using filter paper
configuration, verify that filter screen is in bottom of pan with paper on top of screen.
Filter pump runs, but oil return is very
A. Paper/screen clogged. B. Improperly installed filter pan
components. C. Attempting to filter with oil that
oil occurs.
Verify that O-rings are present and in good condition on filter pan connection fitting. C. In order to properly filter, the oil
is not hot enough.
should be at or near 350ºF (177ºC).
Blockage in filter pan suction tube. Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If bubbling oil occurs, there is a blockage in the filter pan suction tube.
The blockage may be caused by sediment buildup. Use a thin, flexible wire to remove the blockage. If the blockage cannot be removed, call FASC.
but oil does not return to frypot and
there is no bubbling
oil.
7.2.4 Auto Top-Off Problems
A. Fryer temperature must be at
least 300°F (149°C). B. Ensure that oil is above 70°F
A. Fryer temperature too low. B. Temperature of oil too cold. C. Supply line out of JIB. D. CM7 not readdressed after ATO
(21°C). C. Ensure supply line is in JIB. D. Switch all CM7 computers off
off.
and then on again to readdress system. If problem persists call your FASC. 7.2.5 Basket Lift Problems
switch was switched on.
Apply a light coating of Lubriplate™ or similar lightweight white grease to the rod and bushings.
Basket lift movement is jerky
Basket lift rods need lubrication.
and/or noisy.
slow and bubbling · Filter pump runs · Frypots won’t top



Frymaster, L.L.C., 8700 Line Avenue, Shreveport, Louisiana 71106
TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135
1-800-551-8633 819-6339 APRIL 2007
Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No display on the computer. | A. Computer not turned on. | A. Press the ON/OFF switch to turn the computer on. | p.62 |
| No display on the computer. | B. No power to fryer. | B. Verify that the fryer is plugged in and that the circuit breaker is not tripped. | p.62 |
| No display on the computer. | C. Computer, wiring harness or other component has failed. | C. Call FASC. | p.62 |
| Fryer does not heat. Or Display shows HELP with alarm sounding. Heating indicator is on, but burners will not light. | A. Drain valve not fully closed. | A. Verify that the drain valve is fully closed. | p.62 |
| Fryer does not heat. Or Display shows HELP with alarm sounding. Heating indicator is on, but burners will not light. | B. Gas valve is not turned on. | B. Turn the gas valve knob to the ON position. | p.62 |
| Fryer does not heat. Or Display shows HELP with alarm sounding. Heating indicator is on, but burners will not light. | C. Manual gas shut off valve closed. | C. Verify that any in-line manual shut off and main cut-off is open. | p.62 |
| Fryer does not heat. Or Display shows HELP with alarm sounding. Heating indicator is on, but burners will not light. | D. Improperly connected quick- disconnect fitting on gas line. | D. Verify that the quick-disconnect fitting on the flexible gas line is firmly connected to the fryer. | p.62 |
| Fryer does not heat. Or Display shows HELP with alarm sounding. Heating indicator is on, but burners will not light. | E. Obstructed or failed combustion air blower. | E. Verify that combustion air blower is running. If not, call FASC for service. If combustion air blower is functional, clean and adjust per instructions in Chapter 6 of this manual. | p.62 |
| Fryer is operating normally, but recovery is slow when cooking. Or Fryer is slow coming out of melt cycle and displays HELP a short time after coming out of melt cycle. | Dirty or obstructed combustion air blower. | Clean and adjust per instructions in Chapter 6 of this manual. | p.62 |
| Fryer is operating normally, but produces a popping sound when burners ignite. | A. Dirty or obstructed combustion air blower. | A. Clean and adjust per instructions in Chapter 6 of this manual. | p.62 |
| Fryer is operating normally, but produces a popping sound when burners ignite. | B. Dirty or obstructed gas valve vent tube (non-CE fryers only). | B. Clean per instructions in Chapter 6 of this manual. | p.62 |
| Fryer is operating normally, but produces a popping sound when burners ignite. | C. Malfunctioning combustion air blower. | C. If blower is slow to come up to speed, contact FASC for service. | p.62 |
| Heat indicator is on and blower is running, but burner will not ignite. | Blown fuse on interface board or ignition module. | Replace fuse. | p.63 |
| CM7 display is in wrong temperature scale (Fahrenheit or Celsius). | Incorrect display option programmed. | See page 4-16 for instructions. | p.63 |
| CM 7 display shows IGNITION FAILURE. | Open drain valve or problem with latching circuitry. | Verify that the drain valve is fully closed. If the problem continues call your FASC. | p.63 |
| CM7 display shows hot-hi-1. | Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC). | This in an indication of a malfunction in the temperature control circuitry, including a failure of the high-limit thermostat. Shut the fryer down immediately and call your FASC. | p.63 |
| CM 7 display shows HIGH temp. | Fryer temp is above setpoint. | Ensure setpoint is set correctly. If problem persists call your FASC. | p.63 |
| CM7 display shows LOW TEMP. | Frypot temperature is between 180°F (82°C) and 315°F (157°C). | This display is normal when the fryer is first turned on and may appear for a short while if a large batch of frozen product is added to the frypot. If the display never goes out, the fryer is not heating. Shut the fryer down and call your FASC. | p.63 |
| CM7 display shows PROBE FAILURE. | Problem with the temperature measuring circuitry including the probe. | Shut the fryer down and call your FASC. | p.63 |
| CM7 display shows IGNITION FAILURE. | Open drain valve, failed computer, failed transformer, open high-limit thermostat. | Verify that the drain valves are fully closed. Using the ON/OFF switch, turn the computer OFF and then ON again. If this does not correct the problem, call your FASC. | p.63 |
| CM 7 display shows HOT-HI -1. | Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC). | Call your FASC. | p.63 |
| Heat indicator off upon initial startup. Display shows hi or hot with alarm sounding. | Failed computer, damaged wiring harness or connector. | Call your FASC. | p.64 |
| Computer locks up. | Computer error. | Turn the computer OFF and then ON again. If problem persists, contact your FASC. | p.64 |
| Filter Pump won’t start. OR Pump stops during filtering. | A. Power cord is not plugged in or circuit breaker is tripped. | A. Verify that the power cord is fully plugged in. Is so, verify that circuit breaker is not tripped. | p.64 |
| Filter Pump won’t start. OR Pump stops during filtering. | B. Pump motor has overheated causing the thermal overload switch to trip. | B. If the motor is too hot to touch for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch. | p.64 |
| Filter Pump won’t start. OR Pump stops during filtering. | C. Failed filter handle microswitch. Test: If this is a multi-pot fryer, attempt to operate the pump using a different handle. If the pump starts, the handle microswitch is either out of alignment or has failed. When the handle is placed in the ON position, the lever on the microswitch should be firmly pressed against the switch. If so, the switch has failed. If not, the switch is loose and/or misaligned. | C. If the switch is loose, tighten the nuts and bolts holding it in place, ensuring that when the handle is placed in the ON position, the lever on the microswitch is pressed firmly against the switch. If the switch has failed, call FASC. | p.64 |
| Filter Pump won’t start. OR Pump stops during filtering. | D. Filter pump blockage. Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If the pump motor hums for a short time then stops, the probable cause is blockage of the pump itself. | D. Pump blockages are usually caused by sediment build-up in the pump due to improperly sized or installed filter paper and failure to use the crumb screen. Call FASC. | p.64 |
| Filter pump runs, but oil return is very slow and bubbling oil occurs. | A. Paper/screen clogged. B. Improperly installed filter pan components. C. Attempting to filter with oil that is not hot enough. | A. Paper/screen needs changed or cleaned. B. If using filter paper configuration, verify that filter screen is in bottom of pan with paper on top of screen. Verify that O-rings are present and in good condition on filter pan connection fitting. C. In order to properly filter, the oil should be at or near 350ºF (177ºC). | p.65 |
| Filter pump runs but oil does not return to frypot and there is no bubbling oil. | Blockage in filter pan suction tube. Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If bubbling oil occurs, there is a blockage in the filter pan suction tube. | The blockage may be caused by sediment buildup. Use a thin, flexible wire to remove the blockage. If the blockage cannot be removed, call FASC. | p.65 |
| Frypots won’t top off. | A. Fryer temperature too low. B. Temperature of oil too cold. C. Supply line out of JIB. D. CM7 not readdressed after ATO switch was switched on. | A. Fryer temperature must be at least 300°F (149°C). B. Ensure that oil is above 70°F (21°C). C. Ensure supply line is in JIB. D. Switch all CM7 computers off and then on again to readdress system. If problem persists call your FASC. | p.65 |
| Basket lift movement is jerky and/or noisy. | Basket lift rods need lubrication. | Apply a light coating of Lubriplate™ or similar lightweight white grease to the rod and bushings. | p.65 |
Owners and our team usually reply within a day — and your question helps the next person too.