Table of Contents 26 sections Oil Conserving Fryer (OCF30) ™ Electric Series Fryers · Installation & Operation Manual · www.frymaster.com E-mail: [email protected] *8196685* · NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS · … ShowHide
Page 1 of the Frymaster OCF30 user manual — www.frymaster.com E-mail: service@frymaster.com *8196685*
Page 1 · click to enlarge
Page 1

Oil Conserving Fryer (OCF30) ™ Electric Series Fryers

Frymaster OCF30 — Oil Conserving Fryer (OCF30) ™ Electric Series Fryers diagram (page 1)
Fig. 1 · Oil Conserving Fryer (OCF30) ™ Electric Series Fryer…

Installation & Operation Manual

Frymaster OCF30 — Installation & Operation Manual diagram (page 1)
Fig. 2 · Installation & Operation Manual
Frymaster OCF30 — Installation & Operation Manual diagram (page 1)
Fig. 3 · Installation & Operation Manual

Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

24-Hour Service Hotline 1-800-551-8633 JUNE 2011

www.frymaster.com E-mail: [email protected] *8196685*

Page 2 of the Frymaster OCF30 user manual — CANADA
Page 2 · click to enlarge
Page 2

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS MANITOWOC FOOD SERVICE EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS

U.S.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.

CANADA

This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications.

Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.

Page 3 of the Frymaster OCF30 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS
Page 3 · click to enlarge
Page 3
Page 4 of the Frymaster OCF30 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS
Page 4 · click to enlarge
Page 4
Page 4 of the Frymaster OCF30 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS
Page 5 of the Frymaster OCF30 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS
Page 5 · click to enlarge
Page 5
Page 5 of the Frymaster OCF30 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS
Page 6 of the Frymaster OCF30 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS
Page 6 · click to enlarge
Page 6

5.4 Monthly Checks and Service 5-3 5.4.1 Check Controller Setpoint Accuracy 5-3 5.5 Annual/Periodic System Inspection 5-3 5.5.1 Fryer 5-3 5.5.2 Built-In Filtration System 5-4 CHAPTER 6: Operator Troubleshooting

6.1 Introduction 6-1 6.2 Troubleshooting 6-2 6.2.1 Controller and Heating Problems 6-2 6.2.2 Error Message and Display Problems 6-2 6.2.3 Basket Lift Problems 6-3 6.2.4 Filtration Problems 6-4 6.2.5 Auto Top Off Problems 6-4 6.2.6 Error Log Codes 6-5 6.2.7 High Limit Test 6-5 CHAPTER 7: Wiring Diagrams

7.1 Simplified OCF30 Wiring 7-1 7.2 Component Wiring Domestic with 3000 controller 7-2 7.3 Component Wiring Domestic with CM3.5 controller 7-3 7.4 Component Wiring CE 7-4 7.5 Component Wiring CSA 7-5 7.6 Contactor Box-Delta Configuration 7-6 7.7 Contactor Box-WYE Configuration 7-7 ADDENDUM A: Solid Shortening JIB Preparation Instructions ADDENDUM B: Solid Shortening Melter Use Instructions ADDENDUM C: Bulk Oil Instructions

Page 7 of the Frymaster OCF30 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS
Page 7 · click to enlarge
Page 7

1.3 Computer Information

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense. The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. 1.4 European Community (CE) Specific Information The European Community (CE) has established certain specific standards regarding equipment of this type. Whenever a difference exists between CE and non-CE standards, the information or instructions concerned are identified by means of shadowed boxes similar to the one below.

CE Standard Example of box used to distinguish CE and

Non-CE specific information.

1.5 Installation, Operating, and Service Personnel Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.6. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6. 1.6 Definitions QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.

Page 8 of the Frymaster OCF30 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS
Page 8 · click to enlarge
Page 8

QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in person or through a representative, are engaged in and are responsible for the installation of electrical appliances. Qualified personnel must be experienced in such work, be familiar with all electrical precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qualified service personnel are those who are familiar with Frymaster equipment and who have been authorized by Frymaster, L.L.C. to perform service on the equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a minimum amount of parts for Frymaster equipment. A list of Frymaster Factory Authorized Servicers (FAS’s) is located on the Frymaster website at www.frymaster.com Failure to use qualified service personnel will void the Frymaster warranty on your equipment. 1.7 Shipping Damage Claim Procedure What to do if your equipment arrives damaged: Please note that this equipment was carefully inspected and packed by skilled personnel before leaving the factory. Frymaster does not assume responsibility for damage or loss incurred in transit. The freight company assumes full responsibility for safe delivery upon acceptance of the equipment. 1. File Claim for Damages Immediately—Regardless of extent of damage. 2. Visible Loss or Damage—Be sure this is noted on the freight bill or express receipt and is signed by the person making the delivery. 3. Concealed Loss or Damage—If damage is unnoticed until equipment is unpacked, notify the freight company or carrier immediately and file a concealed damage claim. This should be done within 15 days of date of delivery. Be sure to retain container for inspection. 1.8 Service Information For non-routine maintenance or repairs, or for service information, contact your local Frymaster Factory Authorized Servicer (FAS). Service information may also be obtained by calling the Frymaster Technical Services Department at 1-800-551-8633 or 1-318-865-1711 or by e-mail at service@frymaster.com. The following information will be needed in order to assist you efficiently:

Model Number Serial Number Voltage Nature of the Problem

RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.

Page 9 of the Frymaster OCF30 user manual — OCF30 ™ II SERIES ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 9 · click to enlarge
Page 9

OCF30 ™ II SERIES ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS

2.1 General Installation Requirements Proper installation is essential for the safe, efficient, trouble-free operation of this appliance. Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6 of this manual, should perform all installation and service on Frymaster equipment. Failure to use qualified, licensed, and/or authorized installation or service personnel (as defined in Section 1.6 of this manual) to install or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel. Where conflicts exist between instructions and information in this manual and local or national codes or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed. Service may be obtained by contacting your local Frymaster Factory Authorized Servicer.

Page 10 of the Frymaster OCF30 user manual — OCF30 ™ II SERIES ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 10 · click to enlarge
Page 10

DANGER Building codes prohibit a fryer with its open tank of hot oil being installed beside an open flame of any type, including those of broilers and ranges. In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power switch OFF. Do not attempt to start the fryer(s) until power is restored. 2.1.1 Clearance and Ventilation This appliance must be kept free and clear of combustible material, except that it may be installed on combustible floors. A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for servicing and proper operation.

WARNING Do not block the area around the base or under the fryers. 2.1.2 Electrical Grounding Requirements All electrically operated appliances must be grounded in accordance with all applicable national and local codes, and, where applicable, CE codes. All units (cord connected or permanently connected) should be connected to a grounded power supply system. A wiring diagram is located on the inside of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.

Page 11 of the Frymaster OCF30 user manual — OCF30 ™ II SERIES ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 11 · click to enlarge
Page 11

2.1.3 Australian Requirements To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations. 2.2 Power Requirements

Frymaster OCF30 — OCF30 ™ II SERIES ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 11)
Fig. 4
Three (3) Phase Requirements MODELVOLTAGEWIRE SERVICEMINIMUM WIRE SIZE AWG (mm)AMPS (per leg) FPEL1420836 (4.11)39 FPEL1424036 (4.11)34 FPEL1448038 (2.59)17 FPEL14220/38046 (4.11)21 FPEL14240/41546 (4.11)20 FPEL14230/40046 (4.11)21 FPEL1720836 (4.11)48 FPEL1724036 (4.11)41 FPEL1748036 (4.11)21 FPEL17220/38046 (4.11)26 FPEL17240/41546 (4.11)24 FPEL17230/40046 (4.11)25
Page 12 of the Frymaster OCF30 user manual — OCF30 ™ II SERIES ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 12 · click to enlarge
Page 12

2.3 Positioning the Fryer

Frymaster OCF30 — OCF30 ™ II SERIES ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 12)
Fig. 5

DANGER No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633. 1. Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the top of the frypot to verify that the unit is level, both side-to-side and front-to-back.

To level fryers, adjust the casters being careful to ensure the fryer(s) are at the proper height in the frying station. When the fryer is leveled in its final position, install the restraints provided by the KES to limit its movement so that it does not depend on or transmit stress to the electrical conduit or connection. Install the restraints in accordance with the provided instructions. If the restraints are disconnected for service or other reasons, they must be reconnected before the fryer is used.

Frymaster OCF30 — OCF30 ™ II SERIES ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 12)
Fig. 6
2. Close fryer drain-valve(s). 3. Clean and fill frypot(s) to the bottom oil level line with cooking oil. (See Equipment Setup and Shutdown Procedures in Chapter 3.)
Page 13 of the Frymaster OCF30 user manual — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER
Page 13 · click to enlarge
Page 13

OCF30 ™ SERIES ELECTRIC FRYER CHAPTER 3: OPERATING INSTRUCTIONS

FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER

Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 7
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 8
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 9
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 10
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 11

Power Switch (Domestic Only)

Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 12
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 13
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 14
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 15
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 16
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 17
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 18
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 19
Frymaster OCF30 — FINDING YOUR WAY AROUND THE OCF30 ™ SERIES ELECTRIC FRYER diagram (page 13)
Fig. 20

Filter Pan FootPrint Pro Built- In Filtration Unit

Optional JIB (See Sec. 3.3)

TYPICAL CONFIGURATION (FPEL214 SHOWN) NOTE: The appearance of your fryer may differ slightly from that shown depending upon the configuration and date of manufacture.

Show 11 more labels / short text on this page
Lift Rod · Elements · Tilt Housing · Basket Hanger · Top Cap · Controller (3000 Shown) · Bezel · Fuse · Drain Handle · Filter Handle · JIB reset button
Page 14 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYER CHAPTER 3: OPERATING INSTRUCTIONS
Page 14 · click to enlarge
Page 14

3.1 Equipment Setup and Shutdown Procedures

Prior to filling frypots with oil ensure all drains are closed.

1. Fill the frypot with cooking oil to the bottom OIL LEVEL line located on the rear of the frypot. This will allow for oil expansion as heat is applied. Do not fill cold oil any higher than the bottom line; overflow may occur as heat expands the oil. 2. Ensure that the power cord(s) is/are plugged into the appropriate receptacle(s). Verify that the face of the plug is flush with the outlet plate, with no portion of the prongs visible. 3. Ensure that the power is switched on. Some models are equipped with a master switch located behind the fryer door cabinet on the front panel of the component box, next to the fuse. OFF is displayed on the controller. 4. Ensure that the controller is switched ON. When the controller is switched on, the fryer will begin heating and will display MLT-CYCL alternating with the temperature and setpoint until the fryer temperature reaches 180°F (82°C). On CM 3.5 equipped fryers the display changes to LOW TEMP until within 15°F of the setpoint. Then the display changes to product or dashed lines. On the 3000, once the fryer reaches setpoint, the controller display changes to DROP and the fryer is ready for use. To exit the melt cycle on the 3000, press the EXIT COOL button. Answer YES to EXIT MELT? 5. Ensure that the oil level is at the top OIL LEVEL line when the oil is at its cooking temperature.

1. Filter the oil and clean the fryers (See Chapters 5 and 6). If using a CM3.5 reverse steps 1 and 2. 2. Turn the fryer off. 3. Place the frypot covers on the frypots.

3.2 Operation

This fryer is equipped with either 3000 or CM3.5 controllers (illustrated on the following page). Fryers with 3000 controllers should refer to the 3000 Controller Manual 819-6872 for the controller programming and operating procedure. For CM3.5 controllers refer to the separate Frymaster Fryer Controllers User’s Manual furnished with your fryer for the specific controller operating instructions.

Setup · Shutdown

Page 15 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYER CHAPTER 3: OPERATING INSTRUCTIONS
Page 15 · click to enlarge
Page 15
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 15)
Fig. 21

3000 CONTROLLER CM3.5 Refer to Chapter 4 of this manual for operating instructions for the built-in filtration system. 3.3 Optional Oil Attendant® Automatic Top-Off When the Oil Attendant® top-off oil system is in place on the fryer, oil is continually topped off in the frypots from a reservoir in the cabinet. The reservoir holds a 35 pound box of oil. In a typical operation this will last approximately two days before changing. Components of the system are annotated at the right (see Figure 1). NOTE: The system is intended to top off the frypots, not fill them. The frypots will require manual filling upon startup and after disposal.

3.3.1 Prepare the System for Use To prepare the system for its initial operation remove cross brace (see Figure 2). Install the JIB cradle shipped in the accessories pack with the screws that were removed in the cross brace removal step. (see Figure 3). If using the solid shortening option see Appendix A in the rear of this manual for installation instructions.

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 15)
Fig. 22
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 15)
Fig. 23

Figure 2 Figure 3

3.3.2 Install the Oil Reservoir Remove the original lid from the oil container and foil liner. Replace with the provided cap, which has connected suction hardware. Ensure the feeder tube from the cap reaches to the bottom of the oil container. Place the oil container inside the cabinet and slide it into place (as shown on the following page). Avoid catching the suction hardware on the cabinet interior as the container is placed in the fryer. The system is now ready for operation. As the fryer heats to preprogrammed temperatures, the system will energize and then slowly add oil to the frypots as needed, until the oil reaches an optimal level.

Page 16 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYER CHAPTER 3: OPERATING INSTRUCTIONS
Page 16 · click to enlarge
Page 16

3.3.3 Routine Oil Changes When the oil reservoir level is low, the controller displays TOPOFF OIL EMPTY in the left display and CONFIRM in the right display. Press S (CONFIRM). Some procedures may differ from photos shown. Follow manufacturer’s instructions for changing the JIB. If using solid shortening see Appendix B in the rear of this manual for instructions. 1. Open the cabinet and slide the JIB from the cabinet (see Figure 4).

2. Remove the cap and pour any remaining oil in the container into all fry vats equally (see Figure 5).
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 16)
Fig. 24
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 16)
Fig. 25
3. With the jug upright remove the cap and foil seal (see Figure 6).
4. Put the tube in the new full container (see Figure 7).
5. Slide the JIB onto the shelf inside the fryer cabinet (as seen in Figure 4). 6. Press and hold the orange JIB reset switch three (3) seconds to reset the top off system. (see Figure 8).

Figure 8 Image and location may differ from photo.

3.3.4 Bulk Oil Systems

Instructions for installing and using bulk oil systems are found in Appendix C located at the rear of this manual.

Page 17 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 17 · click to enlarge
Page 17

OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 17)
Fig. 26

4.1 Preparing the Built-In Filtration System for Use The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in operation. The FootPrint Pro filtration system is available in three different configurations:

  • Filter Paper – includes crumb tray, large hold-down ring, and metal filter screen.
  • Filter Pad – includes crumb tray, small hold-down ring, and metal filter screen.
  • Magnasol Filter – includes crumb tray and Magnasol filter assembly. Section 4.1.1 covers preparation of the Filter Paper and Filter Pad configurations for use. Refer to Section 4.1.2 for instructions on preparing the Magnasol Filter configuration for use. Operation of all three configurations is the same and is covered in section 4.3. Disassembly and reassembly of the Magnasol filter is covered in section 4.4. 4.1.1 Preparing the Built-In Filtration System for Use with Filter Paper or Filter Pad The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in operation. The FootPrint Pro filtration system uses a filter paper configuration which includes a crumb tray, large hold-down ring, and metal filter screen.
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 17)
Fig. 27
1. Pull the filter pan out from the cabinet and remove the crumb tray, hold-down ring, filter paper and filter screen (see Figure1). Clean all components with a solution of detergent and hot water then dry thoroughly.

The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (SDU) built before January 2004 to be positioned under the drain. Disposal instructions are on page 1-6 in the controller manual 819-6872.

Page 18 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 18 · click to enlarge
Page 18

2. Inspect the filter pan connection fitting to ensure that both O-rings are in good condition (see Figure 2). 3. Then in reverse order, place the metal filter screen in the center of the bottom of the pan, then lay a sheet of filter paper on top of the screen, overlapping on all sides (see Figure1). If using a filter pad, ensure the rough side of the pad is up and lay the pad over the screen, making sure that the pad is in between the embossed ridges of the filter pan. 4. Position the hold-down ring over the filter paper and lower the ring into the pan, allowing the paper to rest on the sides of the filter pan (see Figure 3).

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 18)
Fig. 28

Inspect the filter connection fitting O-rings.

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 18)
Fig. 29
5. When the hold-down ring is in position, if using filter paper, sprinkle one packet of filter powder evenly over the paper. (See Figure 4) 6. Replace the crumb tray in the filter pan, then push the filter pan back into the fryer, positioning it under the drain.
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 18)
Fig. 30

Figure 4 4.1.2 Preparation for Use with the Magnasol Filter Assembly 1. Pull the filter pan out from the cabinet and remove the crumb tray and Magnasol filter assembly (see Figure 5). Clean as directed in section 4.4

seated in the port in the bottom of the pan. Sprinkle one packet of the Magnasol XL filter powder evenly over the screen. 5. Replace the crumb tray, and then push the filter pan back into the fryer, positioning it all the way to the back of the cabinet.

The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (SDU) to be positioned under the drain. NOTE: Refer to Section 4.4 for instructions on how to disassemble and reassemble the Magnasol filter screen assembly. 2. Inspect the fitting on the bottom of the Magnasol filter assembly to ensure that the O-ring is present and in good condition. (See Figure 6) 3. Inspect the filter pan connection fitting to ensure that both O-rings are present and in good condition. (See Figure 2 above). 4. Replace the Magnasol filter assembly in the filter pan, ensuring that the fitting on the bottom of the assembly is securely

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 18)
Fig. 31
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 18)
Fig. 32

Inspect the filter screen O-ring.

Page 19 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 19 · click to enlarge
Page 19

4.2 Filtration

A 3000 controller prompts the user when to filter on the OCF30™ fryer. After a preset number of cook cycles the controller displays filter now? alternating with YES NO. Follow the instructions on page 1-12 of the 3000 controller manual (819-6872). If NO is selected or a cook cycle is started, the controller will prompt again soon to filter the oil. On demand filtration is used to manually start a filter. See page 1-11 of the 3000 controller manual (819-6872) for the filter menu. The fryer MUST be at setpoint temperature for any filtration operation to start. Note: Do NOT filter multiple vats simultaneously. 4.2.1 Operation of the Filter

1. Ensure that the filter is prepared. See Section. 4.1. 2. Make sure the oil is at operating temperature.
3. When prompted, drain the frypot into the filter pan by rotating the drain valve handle 90 º (see Figure 7). If necessary, use the Fryer's Friend clean-out rod to clear the drain from inside the frypot.
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 19)
Fig. 33
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 19)
Fig. 34

Open drain valve by rotating 90º. (Handles may differ from photo.)

Page 20 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 20 · click to enlarge
Page 20
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 20)
Fig. 35
4. After the oil has drained from the frypot and when prompted, rotate the filter handle towards the “ I” to start the pump and begin the filtering process. There may be a slight delay before the pump activates (see Figure 8).
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 20)
Fig. 36

Rotate filter handle to the “I” to start the pump. (Position of handle may differ from

Figure 8 5. The filter pump draws the oil through the filter medium and circulates it back up to and through the frypot during a filter. 6. After the oil is filtered, close the drain valve when prompted and allow the fryer to refill. Let the filter pump run 10 to 12 seconds after the oil begins to bubble. Turn the filter off. 7. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not operate.) 8. Turn the filter off when prompted. The computer displays OFF when finished.

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 20)
Fig. 37
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 20)
Fig. 38

Filter Pump Reset Switch

Page 21 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 21 · click to enlarge
Page 21
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 21)
Fig. 39

WARNING Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to seal the joint between the fry vessels. Banging fry baskets on the strip to dislodge shortening will distort the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for cleaning. 4.3 Disassembly and Reassembly of the Magnasol Filter Dissassembly 1. Grasp the frame with your thumbs on the handles at the corner of the assembly and pull outward in opposite directions to separate the frame at the corner. Continue to open the frame (it will pivot at the opposite corner) until the outer screens and grid can be removed from the frame.

2. Separate
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 21)
Fig. 40
1. Grasp frame with thumbs on these handles and pull frame appart at corner.
2. Separate the outer screens and grid. Cleaning
1. Clean the two frame pieces, outer screens, and grid using a good quality degreaser and hot water from a spray nozzle. The groove in the seal frame pieces can be cleaned with the edge of a Scotch-Brite™ or similar cleaning pad.

the outer screens

Page 22 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 22 · click to enlarge
Page 22

2. At each scheduled boil-out, disassemble the leaf filter assembly and place in the frypot being boiled out. Follow the boil-out procedure in Section 5.3.2 of this manual. 3. Allow all filter assembly components to air dry or thoroughly dry with clean towels before reassembling. Reassembly 1. Place the two outer screens together and align their edges (see illustration below). 2. Insert the screens into one of the frame halves (it doesn’t matter which one). Ensure that the fitting in the bottom screen is on the opposite side of the frame from the handle. 3. Slip the grid between the screens, ensuring that the grid is centered between the edges of the screens. 4. Connect the other half of the frame at the corner opposite the handles and pivot the frame onto the free edges of the screen.

Steps 1 and 2 - Stack outer screens and insert edges into frame.

3. Insert grid between screens after screens have been positioned in frame.
4. Connect corner then pivot frame over free edges of screens.

4.4 Draining and Disposing of Waste Oil When cooking oil is exhausted, the oil must be drained into the filter pan, SDU or other appropriate METAL container for transport to the disposal container or if a bulk oil system is installed, use the bulk oil disposal system by selecting DISPOSE from the filter menu if the fryer is equipped with a 3000 (see page 1-13 of the 3000 controller manual 819-6872.) and follow the prompts and instructions for disposing oil to the bulk oil system. (For safe, convenient draining and disposal of used oil, Frymaster recommends the use of the Frymaster Shortening Disposal Unit (SDU) for JIB systems. The SDU is available through your local distributor.) NOTE: If using an SDU built before January 2004 the filter pan cover must be removed to allow the unit to be positioned beneath the drain. To remove the lid, lift up on the front edge and pull it straight out of the cabinet. Refer to the documentation furnished with your disposal unit for specific operating instructions. If a shortening

Handle

Page 23 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 23 · click to enlarge
Page 23

disposal unit is not available, allow the oil to cool to 100°F (38°C), then drain the oil into a METAL stockpot or similar METAL container.

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 23)
Fig. 41

DANGER Draining and filtering of cooking oil must be accomplished with care to avoid the possibility of a serious burn caused by careless handling. The oil to be filtered is at or near 350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position before operating any switches or valves. Wear all appropriate safety equipment when draining and filtering oil.

DANGER When draining oil into a disposal unit, do not fill above the maximum fill line located on the container. 1. Turn the computer power switch to the OFF position. 2. Position a METAL container with a sealable cover under the drainpipe. The METAL container must be able to withstand the heat of the oil and hold hot liquids. 3. Follow the instructions for disposing of oil on page 1-13 of the 3000 controller manual 819-6872 if equipped with a 3000. Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food particles, use the Fryer’s Friend (poker-like tool) to clear the blockage.

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 23)
Fig. 42

DANGER DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty. 4. After draining the oil, clean all food particles and residual oil from the frypot. BE CAREFUL, this material may still cause severe burns if it comes in contact with bare skin. 5. Ensure the drain valve is closed securely and fill the frypot with clean, filtered or fresh cooking oil to the bottom OIL-LEVEL line.

Page 24 of the Frymaster OCF30 user manual — 5.1 Cleaning the Fryer
Page 24 · click to enlarge
Page 24

OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE

5.1 Cleaning the Fryer

Frymaster OCF30 — 5.1 Cleaning the Fryer diagram (page 24)
Fig. 43 · 5.1 Cleaning the Fryer

WARNING Use a commercial-grade cleaner formulated to effectively clean and sanitize food-contact surfaces. Read the directions for use and precautionary statements before use. Particular attention must be paid to the concentration of cleaner and the length of time the cleaner remains on the food-contact surfaces. 5.2 DAILY CHECKS AND SERVICE 5.2.1 Inspect Fryer and Accessories for Damage- Daily Look for loose or frayed wires and cords, leaks, foreign material in frypot or inside cabinet, and any other indications that the fryer and accessories are not ready and safe for operation. 5.2.2 Clean Inside and Outside of the Fryer Cabinet – Daily Clean inside the fryer cabinet with a dry, clean cloth. Wipe all accessible metal surfaces and components to remove accumulated oil and dust. Clean outside the fryer cabinet with a clean, damp cloth soaked with detergent. Wipe with a clean, damp cloth. 5.2.3 Clean the Built-in Filtration System Daily

Frymaster OCF30 — 5.1 Cleaning the Fryer diagram (page 24)
Fig. 44 · 5.1 Cleaning the Fryer
Page 25 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE
Page 25 · click to enlarge
Page 25

There are no periodic preventive maintenance checks and services required for your FootPrint Pro Filtration System other than daily cleaning of the filter pan and associated components with a solution of hot water and detergent. If you notice that the system is pumping slowly or not at all, verify that the filter pan screen is on the bottom of the filter pan, with the paper on top of the screen. (If the unit is equipped with a Magnasol filter screen rather than with the standard screen and paper system, verify that the O-ring on the bottom fitting of the screen in present and in good condition.) Verify that the two O-ring(s) on the fitting at the right front of the filter pan are present and in good condition. 5.3 WEEKLY CHECKS AND SERVICE 5.3.1 Clean Frypot and Heating Elements

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE diagram (page 25)
Fig. 45

DANGER Never operate the appliance with an empty frypot. The frypot must be filled to the fill line with water or oil before energizing the elements. Failure to do so will result in irreparable damage to the elements and may cause a fire. 5.3.2 Boiling Out the Frypot After the fryer has been in use for a period of time, a hard film of caramelized oil will form on the inside of the frypot. This film should be periodically removed by following the boil out procedure that follows. 1. Before switching the fryer(s) ON, close the frypot drain valve(s), then fill the empty frypot with a mixture of cold water and detergent. Follow instructions on detergent container when mixing. 2. For fryers equipped with 3000 controllers, program the controller for boil-out as described on page 4-14. For fryers equipped with CM 3.5 controllers, program the controller for boil-out as described in the separate Frymaster Fryer Controllers User’s Manual. 3. Simmer the solution for 30 minutes to one hour. Do not allow the water level to drop below the bottom oil-level line in the frypot during the boil-out operation.

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE diagram (page 25)
Fig. 46
4. Turn the fryer ON/OFF switch(s) to the OFF position. 5. Add two gallons (7.6 liters) of water. Drain out the solution and clean the frypot(s) thoroughly.
Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE diagram (page 25)
Fig. 47

WARNING Do not drain boil-out solution into a shortening disposal unit (SDU), a built-in filtration unit, or a portable filter unit. These units are not intended for this purpose, and will be damaged by the solution. 6. Refill the frypot(s) with clean water. Rinse the frypot(s) twice, drain and dry with a clean towel. Thoroughly remove all water from the frypot and elements before refilling the frypot with oil.

Page 26 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE
Page 26 · click to enlarge
Page 26
  • DANGER Remove all drops of water from the frypot before filling with oil. Failure to do so will cause spattering of hot liquid when the oil is heated to cooking temperature. 5.3.3 Clean Detachable Parts and Accessories – Weekly Wipe all detachable parts and accessories with a clean, dry cloth. Use a clean cloth saturated with detergent to remove accumulated carbonized oil on detachable parts and accessories. Rinse the parts and accessories thoroughly with clean water and wipe dry before reinstalling. 5.4 MONTHLY CHECKS AND SERVICE 5.4.1 Check the Controller Set Point Accuracy (This check applies only to units equipped with 3000 or CM3.5 Controllers.) 1. Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the fryer temperature-sensing probe. 2. When the 3000 controller displays “DROP” or the CM3.5 displays a product or dashed lines (indicating that the frypot contents are within the cooking range), press the switch once to display the temperature and setpoint of the cooking oil as sensed by the temperature probe. The setpoint is the temperature with a dot after it. 3. Note the temperature on the thermometer or pyrometer. All three readings should be within ± 5ºF (2ºC) of each other. If not, contact an Factory Authorized Servicer for assistance. 5.5 Annual/Periodic System Inspection This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program. Frymaster recommends that this appliance be inspected at least annually by a Factory Authorized Servicer as follows: 5.5.1 Fryer
  • Inspect the cabinet inside and out, front and rear for excess oil.
  • Verify that the heating element wires are in good condition and that leads have no visible fraying or insulation damage and that they are free of oil.
  • Verify that heating elements are in good condition with no carbon/caramelized oil build-up. Inspect the elements for signs of extensive dry-firing.
  • Verify that the tilt mechanism is working properly when lifting and lowering elements, and that the element wires are not binding and/or chafing.
  • Verify the heating-element amp-draw is within the allowed range as indicated on the appliance’s rating plate.
Page 27 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE
Page 27 · click to enlarge
Page 27
  • Verify that the temperature and high-limit probes are properly connected, tightened and functioning properly, and that mounting hardware and probe guards are present and properly installed.
  • Verify that component box and contactor box components (i.e. controller/controller, relays, interface boards, transformers, contactors, etc.) are in good condition and free from oil and other debris.
  • Verify that component box and contactor box wiring connections are tight and that wiring is in good condition.
  • Verify that all safety features (i.e. contactor shields, drain safety switches, reset switches, etc.) are present and functioning properly.
  • Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in serviceable condition.
  • Verify that all wiring harnesses and connections are tight and in good condition. 5.5.2 Built-In Filtration System
  • Inspect all oil-return and drain lines for leaks and verify that all connections are tight.
  • Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.
  • Verify that all O-rings and seals (including those on the quick-disconnect fittings) are present and in good condition. Replace O-rings and seals if worn or damaged.
  • Check filtration system integrity as follows: − Verify that filter pan cover is present and properly installed. − With the filter pan empty, place each filter handle, one at a time, in the ON position. Verify that

the pump activates and that bubbles appear in the oil of the associated frypot. − Close all oil return valves (i.e., place all filter handles in the OFF position). Verify proper

functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot. − Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to

350°F (177°C) into the filter pan and close the frypot drain valve. Place the filter handle in the ON position. Allow all oil to return to the frypot, indicated by bubbles in the oil. Return the filter handle to the OFF position. The frypot should have refilled in no more than 2 minutes and 30 seconds.

Page 28 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING
Page 28 · click to enlarge
Page 28

OCF30 ™ SERIES ELECTRIC FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING

6.1 Introduction This section provides an easy reference guide to some of the common problems that may occur during the operation of this equipment. The troubleshooting guides that follow are intended to help correct, or at least accurately diagnose, problems with this equipment. Although the chapter covers the most common problems reported, you may encounter problems that are not covered. In such instances, the Frymaster Technical Services staff will make every effort to help you identify and resolve the problem. When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through to the most complex. Never overlook the obvious – anyone can forget to plug in a cord or fail to close a valve completely. Most importantly, always try to establish a clear idea of why a problem has occurred. Part of any corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections, too. If a fuse continues to blow, find out why. Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system. Before calling a service agent or the Frymaster HOTLINE (1-800-24-FRYER):

  • Verify that electrical cords are plugged in and that circuit breakers are on.
  • Verify that frypot drain valves are fully closed.
  • Have your fryer’s model and serial numbers ready to give to the technician assisting you.
Page 29 of the Frymaster OCF30 user manual — Problem Probable Causes Corrective Action
Page 29 · click to enlarge
Page 29

6.2 Troubleshooting 6.2.1 Controller and Heating Problems

Problem Probable Causes Corrective Action

A. Press the ON/OFF switch to turn the

controller on. B. Verify controller power cord is

A. Controller not turned on. B. No power to the fryer. C. Failed controller or other component.

controller.

plugged in and that circuit breaker is not tripped. C. Call your FAS for assistance.

A. Press S (YES) if the vat is full,

otherwise press T (NO). B. Follow controller prompts to clear

A. Normal operation after a filtration. B. Oil may be in the filter pan.

IS VAT FULL?

YES NO after a

message. If problem persists, call your FAS for assistance. Controller displays CHANGE FILTER

filtration.

Daily filter paper change prompt has occurred.

Press S (YES), follow prompts and change the filter paper.

PAPER?

This is normal operation. This will continue until the fryer temperature reaches 180ºF (82ºC).

on and off when first

Fryer is in melt cycle.

started.

A. Verify that all power cords are fully

A. Main power cord not plugged in. B. Drain is open. C. Controller has failed. D. One or more other components have

seated in the receptacles, locked into place and that a circuit breaker is not tripped B. Close drain. C. Call your FAS for assistance D. Call your FAS for assistance.

Fryer does not heat.

failed.

Fryer heats until high-

Temperature probe or controller has failed. Turn fryer off and call your FAS for

limit trips with heat

assistance.

indicator ON.

Fryer heats until high- limit trips without heat

Contactor or controller has failed Call your FAS for assistance.

indicator ON.

6.2.2 Error Messages and Display Problems

Problem Probable Causes Corrective Action

Fryers using the 3000 controller can toggle between F° to C° by pressing the 9 button until Product setup is displayed. Press X to scroll to Tech Mode and press 9. Enter 1658. Press the scan button. The controller displays OFF. Turn the controller on to check temperature. If the desired scale is not displayed, repeat. Fryers using the CM3.5 should refer to the separate Fryer Controllers User’s Manual. Controller displays

Controller display is in

wrong temperature scale (Fahrenheit or

Incorrect display option programmed.

Celsius).

Turn the fryer off and on again. If issue persists call your FAS for assistance.

Failed controller, failed interface board, open high-limit thermostat.

HEATING FAILURE.

No Display on · Controller displays · Fryer repeatedly cycles

Page 30 of the Frymaster OCF30 user manual — PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
Page 30 · click to enlarge
Page 30

Problem Probable Causes Corrective Action

Frypot temperature has dropped more than 21ºF (12ºC) for CM3.5 or 30°F (17°C) for 3000 controllers below setpoint in idle mode or 45°F (25°C) in cook mode.

This display is normal for a short while if a large batch of frozen product is added to the frypot or if the fryer is not heating properly. If the issue persists call your FAS for assistance.

or LOw temp.

Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).

Shut the fryer down immediately and call your FAS for assistance.

Controller displays hot or HOT-hi-1.

Press the power button to turn off fryer and let cool before returning power to fryer. If issue continues call your FAS for assistance.

Frypot temperature is more than 40 ºF (4ºC).

temp.

This display is normal if the fryer setpoint has been changed to a lower temperature. The display should revert to the normal four dashes when the frypot temperature cools to the setpoint. If the setpoint has not been changed, this indicates a problem with the temperature control circuitry. Turn the fryer off and call FAS.

CM III.5 displays HI. Fryer is more than 21ºF (12ºC) above setpoint.

A. Open drain valve B. Failed high limit

A. Close the drain valve. B. Shut the fryer down immediately and

Controller displays hELP HI-2 or High

call your FAS for assistance. Controller displays

limit failure.

Problem with the temperature measuring circuitry including the probe or damaged controller wiring harness or connector.

Shut the fryer down and call your FAS for assistance.

TEMP PROBE FAILURE or PROB.

Verify that both the main power cord and 120V is fully seated in its receptacle, locked into place and that circuit breaker is not tripped If the problem continues call your FAS for assistance.

Heating indicator is on, but fryer is not heating.

Three phase power cord unplugged or circuit breaker is tripped.

Clear error and silence the alarm by pressing the S (YES) button. Maximum recovery time for electric is 1:40. If this error continues call your FAS for assistance.

RECOVERY FAULT/ YES and

Recovery time exceeded maximum time limit.

alarm sounds.

Press the S (YES) button if the issue is fixed or press the T (NO) button to continue cooking and call your FAS for assistance. In some cases, cooking may not be available. 6.2.3 Basket Lift Problems

An error has occurred which requires a service technician.

by an error message.

PROBLEM PROBABLE CAUSES CORRECTIVE ACTION

Apply a light coating of Lubriplate™ or similar lightweight white grease to the rod and bushings.

Basket lift movement is

jerky and/or noisy. Basket lift rods need lubrication.

Show 5 more labels / short text on this page
Controller displays lo · Controller displays Hi · Controller displays · Controller displays · SERVICE REQUIRED followed
Page 31 of the Frymaster OCF30 user manual — OIL IN DRAIN PAN / CONFIRM
Page 31 · click to enlarge
Page 31

6.2.4 Filtration Problems

Problem Probable Causes Corrective Action

Fryer filters after each

Filter prompt setting incorrect. Change the filter prompt setting.

cook cycle.

won’t start. Temperature too low. Ensure fryer is at setpoint before starting; ensure the controller is ON.

Controller displays WAIT FOR FILTER. Another function is still in process. Wait until the previous function ends to

start another filtration cycle.

A. Verify that the power cord is fully

plugged in and the circuit breaker is not tripped. B. If the motor is too hot to touch for

A. Power cord is not plugged in or circuit

breaker is tripped. B. Pump motor has overheated causing

Filter pump won't start

more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch. (See page 5- 4) C. Call your FAS for assistance.

or pump stops during

the thermal overload switch to trip. C. Blockage in filter pump.

filtering.

Remove the oil from the filter pan and replace the filter paper, ensuring that the filter screen is in place under the paper. Verify that O-rings are present and in good condition on filter pan connection fitting. Controller displays

Improperly installed or prepared filter pan components or cold oil.

Filter Pump runs, but oil return is very slow.

Press S (CONFIRM) and follow directions for FILL VAT FROM DRAIN PAN.

Drain valve open or possibility that oil is in drain pan.

OIL IN DRAIN PAN / CONFIRM

6.2.5 Auto Top-Off Problems

Problem Probable Causes Corrective Action Frypots top off cold. Incorrect setpoint. Ensure setpoint is correct.

A. Fryer temperature must be at setpoint. B. Ensure that the oil in the JIB is

A. Fryer temperature too low. B. Oil is too cold. C. JIB out of oil D. Service required error exists

above 70°F (21°C). C. Ensure the JIB is not out of oil and

Frypots won’t top off.

supply line is in the JIB. Replace JIB and press the S button when prompted to reset top off system. If problem persists call your FAS for assistance. D. Call your FAS for assistance.

A. Filter error exists. B. Service required error exists C. Solenoid, pump, pin issue, RTD or

A. Clear filter error properly. If

problem persists call your FAS for assistance. B. Call your FAS for assistance. C. Call your FAS for assistance.

One vat doesn’t top off.

ATO issue.

Filter menu functions

Page 32 of the Frymaster OCF30 user manual — EMPTY / CONFIRM
Page 32 · click to enlarge
Page 32

Problem Probable Causes Corrective Action Controller displays

Fill top off system with oil and press the S (CONFIRM) button.

TOPOFF OIL

Top off system out of oil.

EMPTY / CONFIRM

6.2.6 Error Log Codes (For 3000 Controller Only)

Code ERROR MESSAGE EXPLANATION E03 ERROR TEMP PROBE FAILURE TEMP Probe reading out of range E04 HI 2 BAD High limit reading is out of range. E05 HOT HI 1 High limit temperature is past more than 410°F (210°C), or in CE countries, 395°F (202°C) E06 HEATING FAILURE A component has failed in the high limit circuit such as controller, interface board, contactor or open-high limit. E07 ERROR MIB SOFTWARE Internal MIB software error E08 ERROR ATO BOARD ATO board connection lost; ATO board failure E15 ERROR MIB BOARD Cooking controller detects MIB connections lost; Check software version on each controller. If versions are missing, check CAN connections between each controller; MIB board failure E17 ERROR ATO PROBE ATO RTD reading out of range E20 INVALID CODE LOCATION SD card removed during update E21 CHANGE FILTER PAPER 25 hour timer has expired. Change filter paper and follow prompts. E22 OIL IN PAN ERROR Oil may be present in the filter pan. E25 RECOVERY FAULT Recovery time exceeded maximum time limit. Recovery time should not exceed 1:40 for electric. E27 LOW TEMP ALARM Oil temperature has dropped 30°F (17°C) lower than setpoint in idle mode or 45°F (25°C) in cook mode. (This message may appear if a product is dropped and the start cook button is not pressed immediately or if too large of cook loads are dropped.) 6.2.7 HIGH-LIMIT TEST MODE The high-limit test mode is used to test the high limit circuit. The high-limit test will destroy the oil. It should only be performed with old oil. Shut the fryer off and call for service immediately if the temperature reaches 460°F (238°C) without the high-limit tripping and the computer displays high LIMIT FAILURE alternating with DISCONNECT POWER with an alert tone during testing. The test is cancelled at any time by turning the fryer off. When the fryer is turned back on, it returns to the operating mode and displays the product. 1. Press and hold the check (9) button until MAIN MENU is displayed followed by PRODUCT SETUP.

Page 33 of the Frymaster OCF30 user manual — Problem Probable Causes Corrective Action Controller displays
Page 33 · click to enlarge
Page 33

2. Press the left arrow (W) button until TECH MODE is displayed. 3. Press the check (9) button. 4. Enter 3000. 5. Press the left arrow (W) button until HI LIMIT TEST is displayed. 6. Press the check (9) button. The controller displays HIGH LIMIT YES/NO. 7. Press the up arrow (S) button. 8. The controller displays PRESS AND HOLD CHECK. 9. Press and hold the (9) button to initiate the high-limit test. The vat begins to heat. The computer displays the actual vat temperature during the test. The fryer continues heating until the high limit trips. Generally this happens once the temperature reaches 423°F to 447°F (217°C to 231°C) for non-CE high limits and 405°F to 426°F (207°C to 219°C) for CE high limits. Once the high-limit opens the computer displays HELP HI-2 alternating with the actual temperature (ex. 430F). 10. Release the (9) button. If the high-limit fails, the computer displays HIGH LIMIT FAILURE alternating with DISCONNECT POWER. If this happens, disconnect power to the fryer and call for service immediately. The vat stops heating and the computer displays the current temperature setting alternating with the actual temperature (ex. 430F) until the temperature cools below 400°F (204°C).

11. Press the soft power button to cancel the alarm and go to OFF . 12. Follow the procedure to dispose of the oil.
Page 34 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS
Page 34 · click to enlarge
Page 34

OCF30 ™ SERIES ELECTRIC FRYERS

CHAPTER 7: WIRING DIAGRAMS

7.1 OCF30™ Series Simplified Wiring with 3000 Controller

Page 35 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS
Page 35 · click to enlarge
Page 35

7.2 Component Wiring with 3000 controller (Domestic)

Page 36 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS
Page 36 · click to enlarge
Page 36

7.3 Component Wiring with CM3.5 controller (Domestic)

Page 37 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS
Page 37 · click to enlarge
Page 37

7.4 Component Wiring with CM3.5 Controller (CE)

Page 38 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS
Page 38 · click to enlarge
Page 38

7.5 Component Wiring with CM3.5 Controller (CSA)

Page 39 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS
Page 39 · click to enlarge
Page 39

7.6 Contactor Box – Delta Configuration

Page 40 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS
Page 40 · click to enlarge
Page 40

7.7 Contactor Box – WYE Configuration

Page 41 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYERS
Page 41 · click to enlarge
Page 41

OCF30™ SERIES ELECTRIC FRYER APPENDIX A: JIB Preparation with Solid Shortening Option

1. Open right door of fryer and remove brace in JIB cabinet. 2. Position melter in front of cabinet. Loosen bracket on left side of melter, if necessary, to ease placement in the cabinet. 3. Use the provided screws to attach the melter to existing holes in the interior rails of the fryer cabinet on both sides. See figures 1 and 2. 4. On the back side of the melter, attach the white two-pin connectors and plug in the black connector to the outlet box shown in figure 3. 5. Position the oil reservoir in the melter, sliding the oil pickup tube into the female receptacle. Position the front lid and the front of the melter. See figure 4.

Figure 1: Position the melter in the cabinet and attach with provided screws to the cabinet interior.

Figure 3: Attach the two-pin white connectors and plug the black connector into the utility box as shown.

Figure 4: The assembled melter is shown in position.

Figure 2: Position the melter.

Melter ON/OFF switch. Orange button resets system after a low oil display.

Lift carefully to add shortening.

Page 42 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYER APPENDIX B: Solid Shortening Melter Use
Page 42 · click to enlarge
Page 42

OCF30 ™ SERIES ELECTRIC FRYER APPENDIX B: Solid Shortening Melter Use

Reset oil reservoir system

  • Ensure shortening melter is on.
  • Fill melter with shortening.
  • Allow 2-3 hours for solid shortening to melt. DO NOT attempt to use the top off system with unmelted oil in the top off system. The low oil reservoir display will come on if the fryer calls for oil before the shortening in the melter is liquid.

Lift carefully to add shortening.

  • Once the shortening is fully melted, press and hold the orange reset button to reset the display and reset the top off system.
  • DO NOT ADD hot oil to the shortening melter. The temperature of the oil reservoir should not exceed 140°F. Add small amounts of solid shortening to the reservoir to ensure it has sufficient oil to operate the top-off system.
  • For best results, DO NOT TURN OFF the solid shortening melter overnight.
  • The on/off switch for the melter is also used as a reset switch if the system’s high limit temperature is reached.

Melter ON/OFF switch

Page 43 of the Frymaster OCF30 user manual — OCF30 ™ SERIES ELECTRIC FRYER APPENDIX C: BULK OIL INSTRUCTIONS
Page 43 · click to enlarge
Page 43

OCF30 ™ SERIES ELECTRIC FRYER APPENDIX C: BULK OIL INSTRUCTIONS

C.1.1 Bulk Oil Systems Bulk oil systems have large oil storage tanks, typically located in the rear of the restaurant, that are connected to a rear manifold on the fryer. Some are waste only systems, while others are both waste and fresh oil. Waste oil is pumped from the fryer, via the fitting located on the bottom, to the disposal tanks and fresh oil is pumped from the tanks, thru the fitting located on the top, to the fryer (see Figure 1). The 4-pin wire harness allows connection to various bulk oil systems (see Figure 2). Connect pins 1 and 4 to the tank full switch to prevent overflow of the waste tank. Connect pins 2 and 3 to the fresh oil pump. Set the fryer to bulk through the vat setup mode on the far left controller. See 3000 controller manual section 1.4 on page 1-3. It is imperative that the fryer system be completely power cycled after changing setup from JIB to Bulk.

Frymaster OCF30 — OCF30 ™ SERIES ELECTRIC FRYER APPENDIX C: BULK OIL INSTRUCTIONS diagram (page 43)
Fig. 48

Fresh Oil Connection · Wiring connection · Waste Oil Connection

Page 44 of the Frymaster OCF30 user manual — Operating the Bulk-Oil Equipped Fryer
Page 44 · click to enlarge
Page 44

The OCF™ fryers, equipped for use with bulk oil systems, use an onboard fresh oil jug typically supplied by the bulk oil vendor. Remove the cap and insert the standard fitting into the jug with the metal cap resting on the lip of the jug. The oil is pumped in and out of the jug through the same fitting (see Figure 3).

Frymaster OCF30 — Operating the Bulk-Oil Equipped Fryer diagram (page 44)
Fig. 49 · Operating the Bulk-Oil Equipped Fryer

Operating the Bulk-Oil Equipped Fryer

Frymaster OCF30 — Operating the Bulk-Oil Equipped Fryer diagram (page 44)
Fig. 50 · Operating the Bulk-Oil Equipped Fryer

Bulk Oil Rocker Panel

JIB Empty Reset Press after refilling JIB

Frymaster OCF30 — Operating the Bulk-Oil Equipped Fryer diagram (page 44)
Fig. 51 · Operating the Bulk-Oil Equipped Fryer

with Add Oil button. This is done with the fryer in Normal Mode.

Frymaster OCF30 — Operating the Bulk-Oil Equipped Fryer diagram (page 44)
Fig. 52 · Operating the Bulk-Oil Equipped Fryer
Frymaster OCF30 — Operating the Bulk-Oil Equipped Fryer diagram (page 44)
Fig. 53 · Operating the Bulk-Oil Equipped Fryer

Leave fryer in Normal Mode unless disposing

Oil Disposal Pull to dispose of oil in filter pan. Fryer must be

Frymaster OCF30 — Operating the Bulk-Oil Equipped Fryer diagram (page 44)
Fig. 54 · Operating the Bulk-Oil Equipped Fryer

in Bulk Mode.

of oil or filling vat from

Frymaster OCF30 — Operating the Bulk-Oil Equipped Fryer diagram (page 44)
Fig. 55 · Operating the Bulk-Oil Equipped Fryer

bulk tank.

Frymaster OCF30 — Operating the Bulk-Oil Equipped Fryer diagram (page 44)
Fig. 56 · Operating the Bulk-Oil Equipped Fryer

Oil Return Turn to fill empty vat

Frymaster OCF30 — Operating the Bulk-Oil Equipped Fryer diagram (page 44)
Fig. 57 · Operating the Bulk-Oil Equipped Fryer

with fresh oil. Fryer must be in Bulk Mode.

C.1.2 Filling the JIB

1. “TOPOFF OIL EMPTY” message appears on the controller. 2. Ensure the rocker switch is in Normal Mode. 3. Press and hold the orange button above rocker switch to fill the JIB. 4. Once the JIB is full, release the button. 5. Press orange JIB reset button to remove the Topoff Oil Empty message and return to normal operation.

* NOTE: It takes approximately 10 seconds from the time the button is pressed until the fresh oil pump starts. It may take up to 15 seconds before the level in the JIB begins to rise. It takes approximately four minutes to fill the JIB. C.1.3 Dispose of Waste Oil

1. Ensure filter pan is prepared for filtration. 2. Drain vat into filter pan. 3. At rocker panel, switch to Bulk Mode.

Add Oil Button · Rocker Switch · Waste Full Light

Page 45 of the Frymaster OCF30 user manual — Operating the Bulk-Oil Equipped Fryer
Page 45 · click to enlarge
Page 45
4. Unlock dispose valve handle. 5. Pull the oil disposal valve and the pump will engage and empty the filter pan to the waste oil tank. The Waste Full light on the rocker panel will illuminate if the tank is full. 6. Filling with fresh oil? See Fill Vat from Bulk below. If not, switch to Normal Mode at rocker panel C.1.4 Fill Vat from Bulk Tank

1. Ensure vat is empty and the drain valve is closed. 2. At the rocker panel, switch to Bulk Mode. 3. Open the return valve on the empty tank. Press the Add Fresh Oil button. Fill to the lower line in the frypot. 4. Close the return valve. 5. Ensure the filter pan is empty. 6. At the rocker panel, switch to Normal Mode. * NOTE: It takes approximately fifteen seconds from the time the Add Fresh Oil button is pressed until the bulk fresh oil pump starts. It may take up to 25 seconds before the level in the vat begins to rise. It takes approximately one minute to fill a split vat and two minutes to fill a full vat.

Page 46 of the Frymaster OCF30 user manual — PRINTED IN THE UNITED STATES SERVICE HOTLINE
Page 46 · click to enlarge
Page 46
Frymaster OCF30 — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 46)
Fig. 58
Frymaster OCF30 — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 46)
Fig. 59

Frymaster, L.L.C., 8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 (Tech Support Fax) 1-318-219-7135

PRINTED IN THE UNITED STATES SERVICE HOTLINE

819-6685 JUNE 2011

1-800-551-8633

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No Display on controller.A. Controller not turned on. B. No power to the fryer. C. Failed controller or other component.A. Press the ON/OFF switch to turn the controller on. B. Verify controller power cord is plugged in and that circuit breaker is not tripped. C. Call your FAS for assistance. p.29
Controller displays IS VAT FULL? YES NO after a filtration.A. Normal operation after a filtration. B. Oil may be in the filter pan.A. Press S (YES) if the vat is full, otherwise press T (NO). B. Follow controller prompts to clear message. If problem persists, call your FAS for assistance. p.29
Controller displays CHANGE FILTER PAPER?Daily filter paper change prompt has occurred.Press S (YES), follow prompts and change the filter paper. p.29
Fryer repeatedly cycles on and off when first started.Fryer is in melt cycle.This is normal operation. This will continue until the fryer temperature reaches 180ºF (82ºC). p.29
Fryer does not heat.A. Main power cord not plugged in. B. Drain is open. C. Controller has failed. D. One or more other components have failed.A. Verify that all power cords are fully seated in the receptacles, locked into place and that a circuit breaker is not tripped B. Close drain. C. Call your FAS for assistance D. Call your FAS for assistance. p.29
Fryer heats until high- limit trips with heat indicator ON.Temperature probe or controller has failed.Turn fryer off and call your FAS for assistance. p.29
Fryer heats until high- limit trips without heat indicator ON.Contactor or controller has failedCall your FAS for assistance. p.29
Controller display is in wrong temperature scale (Fahrenheit or Celsius).Incorrect display option programmed.Fryers using the 3000 controller can toggle between F° to C° by pressing the 9 button until Product setup is displayed. Press X to scroll to Tech Mode and press 9. Enter 1658. Press the scan button. The controller displays OFF. Turn the controller on to check temperature. If the desired scale is not displayed, repeat. Fryers using the CM3.5 should refer to the separate Fryer Controllers User’s Manual. p.29
Controller displays HEATING FAILURE.Failed controller, failed interface board, open high-limit thermostat.Turn the fryer off and on again. If issue persists call your FAS for assistance. p.29
Controller displays lo or LOw temp.Frypot temperature has dropped more than 21ºF (12ºC) for CM3.5 or 30°F (17°C) for 3000 controllers below setpoint in idle mode or 45°F (25°C) in cook mode.This display is normal for a short while if a large batch of frozen product is added to the frypot or if the fryer is not heating properly. If the issue persists call your FAS for assistance. p.30
Controller displays hot or HOT-hi-1.Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).Shut the fryer down immediately and call your FAS for assistance. p.30
Controller displays Hi temp.Frypot temperature is more than 40 ºF (4ºC).Press the power button to turn off fryer and let cool before returning power to fryer. If issue continues call your FAS for assistance. p.30
CM III.5 displays HI.Fryer is more than 21ºF (12ºC) above setpoint.This display is normal if the fryer setpoint has been changed to a lower temperature. The display should revert to the normal four dashes when the frypot temperature cools to the setpoint. If the setpoint has not been changed, this indicates a problem with the temperature control circuitry. Turn the fryer off and call FAS. p.30
Controller displays hELP HI-2 or High limit failure.A. Open drain valve B. Failed high limitA. Close the drain valve. B. Shut the fryer down immediately and call your FAS for assistance. p.30
Controller displays TEMP PROBE FAILURE or PROB.Problem with the temperature measuring circuitry including the probe or damaged controller wiring harness or connector.Shut the fryer down and call your FAS for assistance. p.30
Heating indicator is on, but fryer is not heating.Three phase power cord unplugged or circuit breaker is tripped.Verify that both the main power cord and 120V is fully seated in its receptacle, locked into place and that circuit breaker is not tripped If the problem continues call your FAS for assistance. p.30
Controller displays RECOVERY FAULT/ YES and alarm sounds.Recovery time exceeded maximum time limit.Clear error and silence the alarm by pressing the S (YES) button. Maximum recovery time for electric is 1:40. If this error continues call your FAS for assistance. p.30
Controller displays SERVICE REQUIRED followed by an error message.An error has occurred which requires a service technician.Press the S (YES) button if the issue is fixed or press the T (NO) button to continue cooking and call your FAS for assistance. In some cases, cooking may not be available. p.30
Basket lift movement is jerky and/or noisy.Basket lift rods need lubrication.Apply a light coating of Lubriplate™ or similar lightweight white grease to the rod and bushings. p.30
Fryer filters after each cook cycle.Filter prompt setting incorrect.Change the filter prompt setting. p.31
Filter menu functions won’t start.Temperature too low.Ensure fryer is at setpoint before starting; ensure the controller is ON. p.31
Controller displays WAIT FOR FILTER.Another function is still in process.Wait until the previous function ends to start another filtration cycle. p.31
Filter pump won't start or pump stops during filtering.A. Power cord is not plugged in or circuit breaker is tripped. B. Pump motor has overheated causing the thermal overload switch to trip. C. Blockage in filter pump.A. Verify that the power cord is fully plugged in and the circuit breaker is not tripped. B. If the motor is too hot to touch for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch. (See page 5- 4) C. Call your FAS for assistance. p.31
Filter Pump runs, but oil return is very slow.Improperly installed or prepared filter pan components or cold oil.Remove the oil from the filter pan and replace the filter paper, ensuring that the filter screen is in place under the paper. Verify that O-rings are present and in good condition on filter pan connection fitting. p.31
Controller displays OIL IN DRAIN PAN / CONFIRMDrain valve open or possibility that oil is in drain pan.Press S (CONFIRM) and follow directions for FILL VAT FROM DRAIN PAN. p.31
Frypots top off cold.Incorrect setpoint.Ensure setpoint is correct. p.31
Frypots won’t top off.A. Fryer temperature too low. B. Oil is too cold. C. JIB out of oil D. Service required error existsA. Fryer temperature must be at setpoint. B. Ensure that the oil in the JIB is above 70°F (21°C). C. Ensure the JIB is not out of oil and supply line is in the JIB. Replace JIB and press the S button when prompted to reset top off system. If problem persists call your FAS for assistance. D. Call your FAS for assistance. p.31
One vat doesn’t top off.A. Filter error exists. B. Service required error exists C. Solenoid, pump, pin issue, RTD or ATO issue.A. Clear filter error properly. If problem persists call your FAS for assistance. B. Call your FAS for assistance. C. Call your FAS for assistance. p.31
Controller displays TOPOFF OIL EMPTY / CONFIRMTop off system out of oil.Fill top off system with oil and press the S (CONFIRM) button. p.32

Ask about the Frymaster OCF30

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster OCF30

Be the first to ask — other owners or our team will answer.

Original document

Frymaster OCF30 manual PDF

46 pages·2.4 MB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…