EN
Frymaster logo
Official user manual

Frymaster MPH55

44 pages·1.5 MB·Fryer·PDF·ENDEFRITNLJA
Frymaster MPH55
Table of Contents 32 sections OPERATOR’S MANUAL FRYMASTER BIPH55/MPH55 SERIES · GAS FRYER · MANUFACTURED · BY · … ShowHide
Page 2 of the Frymaster MPH55 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 2 · click to enlarge
Page 2

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS

U.S.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.

CANADA This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set

out by the ICES-003 standard of the Canadian Department of Communications.

Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.

Page 3 of the Frymaster MPH55 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 3 · click to enlarge
Page 3

DANGER This product contains chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.

Page 4 of the Frymaster MPH55 user manual — C. WARRANTY PROVISIONS – COMBUSTION CHAMBERS
Page 4 · click to enlarge
Page 4

WARRANTY STATEMENT

Frymaster, L.L.C. makes the following limited warranties to the original purchaser only for this equipment and replacement parts:

A. WARRANTY PROVISIONS - FRYERS

1. Frymaster L.L.C. warrants all components against defects in material and workmanship for a period of one year.
2. All parts, with the exception of the frypot, heating elements and fuses, are warranted for one year after installation date of fryer.
3. If any parts, except fuses and filter O-rings, become defective during the first year after installation date, Frymaster will also pay straight-time labor costs to replace the part, plus up to 100 miles/160 km of travel (50 miles/80 km each way).

B. WARRANTY PROVISIONS - FRYPOTS (Applies to fryers manufactured after December 1, 2003, only.)

1. Frymaster warrants the frypot assembly for ten years parts and labor. Components attached to the frypot, such as the high-limit, probe, gaskets, seals, ignitors and related fasteners, are also covered by the ten-year warranty if replacement is necessitated by the frypot replacement. Components that are not part of the frypot assembly, such as the blower, gas valve, micro switches, doors and cabinetry are not covered by the frypot warranty. If the frypot is found to be defective, Frymaster will replace the frypot, allowing up to the maximum time per the Frymaster time allowance chart hours of straight-time labor plus up to 100 miles/160 km of travel (50 miles/80 km each way) to change the frypot. 2. This warranty is limited to fryers operating on natural or propane (LP) gas. Fryers that operate on manufactured gas (also known as town gas or high-hydrogen gas) have a lifetime frypot warranty, parts only.

C. WARRANTY PROVISIONS – COMBUSTION CHAMBERS

(Applies to fryers installed on or after November 1, 1994, only.)

1. Frymaster L.L.C. warrants the combustion chambers against defective material or workmanship for a period of ten years from the original installation date, parts and labor. 2. The combustion chamber consists of the infrared burners and the structural components to mount the burners. This warranty does not cover ancillary components, including the igniter, blower, high-limit thermostat, and temperature probe.
3. This warranty is limited to fryers operating on natural or propane (LP) gas.
Page 5 of the Frymaster MPH55 user manual — F. WARRANTY EXCLUSIONS
Page 5 · click to enlarge
Page 5

D. WARRANTY PROVISIONS - COOKING COMPUTER

1. Frymaster L.L.C. warrants the M-2000 Cooking Computer against defective material or workmanship for a period of three years from the original installation date. If the unit fails within the first year, warranty will cover part and labor. If the part fails the second year, warranty will cover part only. Labor is charged to the store. The third year, warranty will cover the part at a reduced cost of $90.00. No labor or handling will be covered.
2. During this warranty period, Frymaster will replace a returned defective cooking computer with a new or factory rebuilt and functionally operative units.
3. For replacement of defective computers under warranty, call your local Frymaster Authorized Service Center. All computers replaced under the Frymaster exchange program only carry the remaining original warranty.

E. PARTS RETURN

All defective in-warranty parts must be returned to a Frymaster Authorized Factory Service Center within 60 days for credit. After 60 days, no credit will be allowed.

F. WARRANTY EXCLUSIONS

This warranty does not cover equipment that has been damaged due to misuse, abuse, alteration, or accident such as: • improper or unauthorized repair (including any frypot which is welded in the field);

  • failure to follow proper installation instructions and/or scheduled maintenance procedures as prescribed in your MRC cards. Proof of scheduled maintenance is required to maintain the warranty;
  • improper maintenance;
  • damage in shipment;
  • abnormal use;
  • removal, alteration, or obliteration of either the rating plate or the date code on the heating elements;
  • operating the frypot without shortening or other liquid in the frypot;
  • no fryer will be warranted under the ten-year program for which a proper start-up form has not been received.

This warranty also does not cover: • transportation or travel over 100 miles/160 km (50 miles/80 km each way), or travel over two hours;

  • overtime or holiday charges;
  • consequential damages (the cost of repairing or replacing other property which is damaged), loss of time, profits, use or any other incidental damages of any kind.

There are no implied warranties of merchantability or fitness for any particular use or purpose. This warranty is applicable at the time of this printing and is subject to change.

Page 6 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER
Page 6 · click to enlarge
Page 6

BIPH55 / MPH55 SERIES GAS FRYER

CHAPTER 1: INTRODUCTION

1.1 General

Read the instructions in this manual thoroughly before attempting to operate this equipment. This manual covers all configurations of models MPH55 and BIPH55 fryers. Models designated MPH55 do not have built-in filtration systems. Models designated BIPH55 are equipped with FootPrint Pro built-in filtration systems. The fryers in this model family have most parts in common, and when discussed as a group, will be referred to as “Pro Series H55” fryers. Although similar in appearance to the BIH52 McDonald’s fryers, the BIPH55 fryers feature a significantly different built-in filtration system. The new Euro-Look incorporates rounded topcaps and large round drains, which ensures that fries and other debris will be washed into the filter pan. Other features, including the deep cold-zones and easy to clean, open frypots remain essentially unchanged. All Pro Series H55 Gas fryers come standard with M2000 computer, electronic ignition, melt cycle, and boil-out mode.

Fryers in this series come in full- or split-vat arrangements, and can be purchased as single units or in batteries of up to five fryers. Pro Series H55 high-efficiency gas fryers employ a unique infrared burner system that uses up to 43% less energy to cook the same volume as conventional open-burner fryers. All Pro Series H55 Gas fryers are of an open-frypot design with no tubes and have a hand-sized opening into the deep cold zone, which makes cleaning the stainless frypot quick and easy. Heating is supplied by a pair of infrared burner assemblies mounted on each side of the frypot. A dedicated blower mounted on the front of the frypot supplies combustion air for the burners. Pro Series H55 Gas fryers can be configured for natural gas, propane (LP), or manufactured gas, as required by the customer. Each frypot is equipped with a temperature probe for precise temperature control. All fryers in this series require an external source of AC electrical power. Units can be configured for voltages ranging from 100 VAC to 240 VAC. BIPH55 and MPH55 fryers are shipped completely assembled. All fryers are shipped with a package of standard accessories. Each fryer is adjusted, tested, and inspected at the factory before crating for shipment.

This appliance is only for professional use and shall be used by qualified personnel only, as defined in Section 1.6.

Page 7 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER
Page 7 · click to enlarge
Page 7

1.2 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones that follow.

in a malfunction of your system.

in damage to your system, and which may cause your system to malfunction.

in injury to personnel, and which may cause damage to your system and/or cause your

system to malfunction. Your fryer is equipped with automatic safety features: 1. High temperature detection shuts off gas to the burner assembly should the controlling thermostat fail. 2. A safety switch built into the drain valve on units with filter systems prevents burner ignition with the drain valve even partially open.

1.3 Computer Information for the M2000 Computers

FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device, pur- suant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harm- ful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The user is cautioned that any changes or modifications not expressly approved by the party respon- sible for compliance could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions.

Page 8 of the Frymaster MPH55 user manual — QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Page 8 · click to enlarge
Page 8

The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.

1.4 European Community (CE) Specific Information

The European Community (CE) has established certain specific standards regarding equipment of this type. Whenever a conflict exists between CE and non-CE standards, the information or instructions concerned are identified by means of shadowed boxes. 1.5 Installation, Operating, and Service Personnel

Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.6. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6. 1.6 Definitions

QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL

Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual. QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in person or through a representative, are engaged in and are responsible for the installation of gas- fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qualified service personnel are those who are familiar with Frymaster equipment and who have been authorized by Frymaster, L.L.C. to perform service on the equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a minimum amount of parts for Frymaster equipment. A list of Frymaster Factory Authorized Service Centers (FASC) is included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Frymaster warranty on your equipment.

Page 9 of the Frymaster MPH55 user manual — QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Page 9 · click to enlarge
Page 9

1.7 Shipping Damage Claim Procedure

Your Frymaster equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsibility for safe delivery upon its acceptance of the equipment for transport. What to do if your equipment arrives damaged:

1. File a claim for damages immediately , regardless of the extent of damages.
2. Inspect for and record all visible loss or damage , and ensure that this information is noted on the freight bill or express receipt and is signed by the person making the delivery.
3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be recorded and reported to the freight company or carrier immediately upon discovery. A concealed damage claim must be submitted within 15 days of the date of delivery. Ensure that the shipping container is retained for inspection.

Frymaster DOES NOT ASSUME RESPONSIBILITY FOR DAMAGE OR LOSS

INCURRED IN TRANSIT.

1.8 Parts Ordering and Service Information

For non-routine maintenance or repairs, or for service information, contact your local Frymaster Authorized Service Center (FASC). In order to assist you quickly, the Frymaster Factory Authorized Service Center (FASC) or Service Department representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the fryer door. Part numbers are found in the Installation, Operation, Service, and Parts Manual. Parts orders may be placed directly with your local FASC or distributor. Included with fryers when shipped from the factory is a list of Frymaster FASCs. If you do not have access to this list, contact the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711. When ordering parts, the following information is required:

Model NumberSerial Number: Type of Gas or Voltage: Item Part Number: Quantity Needed:
Page 10 of the Frymaster MPH55 user manual — QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Page 10 · click to enlarge
Page 10

Service information may be obtained by contacting your local FASC/Distributor. Service may also be obtained by calling the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711. When requesting service, please have the following information ready:

Model Number: Serial Number: Type of Gas: In addition to the model number, serial number, and type of gas, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem.

RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.

Page 11 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 11 · click to enlarge
Page 11

BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS

2.1 General Installation Requirements Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6 of this manual, should perform all installation and service on Frymaster equipment. Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.6 of this manual. Failure to use qualified, licensed, and/or authorized installation or service personnel (as de- fined in Section 1.6 of this manual) to install, convert to another gas type or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel. Where conflicts exist between instructions and information in this manual and local or na- tional codes or regulations, installation and operation shall comply with the codes or regula- tions in force in the country in which the equipment is installed.

DANGER Frymaster appliances equipped with legs are for stationary installations. Appliances fitted with legs must be lifted during movement to avoid damage to the appliance and bodily injury. For movable installations, optional equipment casters must be used. Questions? Call 1-800-551-8633. 2.1.1 CLEARANCE AND VENTILATION The fryer(s) must be installed with a 6” (150 mm) clearance at both sides and back when installed adjacent to combustible construction; no clearance is required when installed adjacent to noncombustible construction. A minimum of 24” (600 mm) clearance should be provided at the front of the fryer.

Page 12 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 12 · click to enlarge
Page 12

One of the most important considerations of efficient fryer operation is ventilation. Make sure the fryer is installed so that products of combustion are removed efficiently, and that the kitchen ventilation system does not produce drafts that interfere with burner operation. The fryer flue opening must not be placed close to the intake of the exhaust fan, and the fryer must never have its flue extended in a “chimney” fashion. An extended flue will change the combustion characteristics of the fryer, causing longer recovery time. It also frequently causes delayed ignition. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear must be kept clear and unobstructed.

Fryers must be installed in an area with an adequate air supply and adequate ventilation. Adequate distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank. Filters should be installed at an angle of 45º. Place a drip tray beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96 states, “A minimum distance of 18 in. (450 mm) should be maintained between the flue outlet and the lower edge of the grease filter.” Frymaster recommends that the minimum distance be 24 in. (600 mm) from the flue outlet to the bottom edge of the filter when the appliance consumes more than 120,000 BTU per hour. For installations in the United States, information on construction and installation of ventilating hoods can be found in the NFPA standard cited above. A copy of the standard may be obtained from the National Fire Protection Association, Battery March Park, Quincy, MA 02269. 2.1.2 NATIONAL CODE REQUIREMENTS The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped “NAT” only to natural gas, those stamped “PRO” only to propane gas, and those stamped “MFG” only to manufactured gas. Installation shall be made with a gas connector that complies with national and local codes, and, where applicable, CE codes. Quick-disconnect devices, if used, shall likewise comply with national, local, and, if applicable, CE codes. 2.1.3 ELECTRICAL GROUNDING REQUIREMENTS All electrically operated appliances must be grounded in accordance with all applicable national and local codes, and, where applicable, CE codes. All units (cord connected or permanently connected) should be connected to a grounded power supply system. A wiring diagram is located on the inside of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.

Page 13 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 13 · click to enlarge
Page 13

2.1.4 Australian Requirements

To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.

2.2 Caster Installation

Depending upon the specific configuration ordered, your fryer may have been shipped without installed casters. DO NOT INSTALL THIS APPLIANCE WITHOUT CASTERS. If the appliance requires the installation of casters, install them in accordance with the instructions included in your accessory package. 2.3 Pre-Connection Preparations

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 13)
Fig. 1

After the fryer has been positioned under the exhaust hood, ensure the following has been accomplished: 1. Adequate means must be provided to limit the movement of fryers without depending upon the gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all times when the fryer is in use. The restraining cable and installation instructions are packed with the flexible hose in the accessories box that was shipped with your unit. 2. Single unit fryers must be stabilized by installing restraining chains on fryers equipped with casters. Follow the instructions in the accessory pack to install the chains.

Page 14 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 14 · click to enlarge
Page 14
3. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the hood be 24 in. (600 mm) when the appliance consumes more than 120,000 BTU per hour. NOTE: There are no built-in leveling devices on fryers equipped with casters. The floor where the fryer is to be installed must be level. 4. Test the fryer electrical system:

a. Plug the fryer electrical cord(s) into a grounded electrical receptacle. NOTE: To ensure the

safe and efficient operation of the fryer and hood, the electrical plug for the 120-volt line, which powers the hood, must be fully engaged and locked in its pin and sleeve socket.

b. Place the power switch in the ON position.

  • For fryers having computers, verify that the display indicates OFF .
  • If the store is equipped with a hood interlock system, the hood exhaust fan should be on. If not, the store hood interlock system is improperly wired and must be corrected.

c. Place the fryer power switch in the OFF position. Verify that the power and heat lights are

out. 5. Refer to the data plate on the inside of the fryer door to determine if the fryer burner is configured for the proper type of gas before connecting the fryer quick-disconnect device or piping from the gas supply line. 6. Verify the minimum and maximum gas supply pressures for the type of gas to be used in accordance with the accompanying tables.

CE Standard for Incoming Gas Pressures for Fryers Manufactured After April 1999

G20 20 2 x 3.40 2 x 3.40 7 mbar 7 mbar

G25 20 or 25 2 x 3.40 2 x 3.40 10 mbar 10 mbar

G30 28/30 or 50 2 x 2.05 2 x 2.05 17 mbar 17 mbar

G31 37 or 50 2 x 2.05 2 x 2.05 20 mbar 20 mbar

(1) mbar = 10,2 mm H2O

Show 13 more labels / short text on this page
Orifice Diameter · Regulator Pressure · Pressure · Single · Dual · Single · Dual · Gas · (mbar)(1) · Vat · Vat · Vat · Vat
Page 15 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 15 · click to enlarge
Page 15
Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 15)
Fig. 2

14" W.C. 3.48 kPa 34.84 mbar 7. For fryers equipped with a FootPrint Pro system (BIPH55 models) plug the electrical cord(s) into a power receptacle behind the fryer.

2.4 Connection to Gas Line

Never use matches, candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply to the appliance at the main shut-off valve and immediately contact the local gas company or an authorized service agency for service.

DANGER “Dry-firing” your unit will cause damage to the frypot and can cause a fire. Always ensure that melted shortening, cooking oil, or water is in the frypot before firing the unit. The size of the gas line used for installation is very important. If the line is too small, the gas pressure at the burner manifold will be low. This may cause slow recovery and delayed ignition. The incoming gas supply line should be a minimum of 1½” (38 mm) in diameter. Refer to the chart on the following page for the minimum sizes of connection piping.

Page 16 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 16 · click to enlarge
Page 16
Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 16)
Fig. 3

Gas Connection Pipe Sizes (Minimum incoming pipe size should be 1 1/2" (41 mm))

Gas Single Unit 2 - 3 Units 4 or more units*

Natural 3/4" (22 mm) 1" (28 mm) 1 1/4" (36 mm)

Propane 1/2" (15 mm) 3/4" (22 mm) 1" (28 mm)

Manufactured 1" (28 mm) 1 1/4" (36 mm) 1 1/2" (41 mm)

  • For distances of more than 20 feet (6 m) and/or more than 4 fittings or elbows, increase the connection by one pipe size. The Pro Series H55 gas fryer has received the CE mark for the countries and gas categories indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU and category 3P/B, which is 23kW.

CE Approved Gas Categories by Country

COUNTRIES CATEGORIES GAS PRESSURE (MBAR) G20 20 AUSTRIA (AT) II2H3B/P G30, G31 50 I2E(R)B G20, G25 20, 25 BELGIUM (BE) I3+ G30, G31 28-30, 37 G20 20 DENMARK (DK) II2H3B/P G30, G31 30 G20, G25 20, 25 II2Esi3+ G30, G31 28-30, 37 G20, G25 20, 25 FRANCE (FR)

II2Esi3P G31 50 G20 20 FINLAND (FI) II2H3B/P G30, G31 30 G20, G25 20 II2ELL3B/P G30, G31 50 GERMANY (DE)

I3P G31 50 G20 20 GREECE (GR) II2H3+ G30, G31 28-30, 37 G20 20 ITALY (IT) II2H3+ G30, G31 28-30, 37 G20 20 IRELAND (IE) II2H3+ G30, G31 28-30, 37 G20 20 LUXEMBOURG (LU) II2E3B/P G30, G31 50 G25 25 II2L3P G31 50 G25 25 NETHERLANDS (NL)

II2L3B/P G30, G31 30 NORWAY (NO) I3B/P G30, G31 30 G20 20 PORTUGAL (PT) II2H3+ G30, G31 28-30, 37 G20 20 II2H3+ G30, G31 28-30, 37 G20 20 SPAIN (ES)

II2H3P G31 37, 50 G20 20 SWEDEN (SE) II2H3B/P G30, G31 30 G20 20 UNITED KINGDOM (UK) II2H3+ G30, G31 28-30, 37

Page 17 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 17 · click to enlarge
Page 17

CE Standard Required airflow for the combustion air supply is 2m3/h per kW.

1. Connect the quick-disconnect hose to the fryer quick-disconnect fitting under the front of the fryer and to the building gas line.

When using thread compound, use very small amounts on male threads only. Use a pipe thread compound that is not affected by the chemical action of LP gases (Loctite™ PST56765 Sealant is one such compound). DO NOT apply compound to the first two threads. Doing so may allow some of the compound to enter the gas stream, resulting in clogging of burner orifices and/or the control valve. 2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A soap solution should be used for this purpose. 3. Close the fryer drain valve and fill the frypot with water and boil-out solution to the bottom OIL LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are described in the “Lighting Instructions” and “Boiling Out the Frypot” topics found in Chapter 3 of this manual.

4. The burner manifold pressure should be checked at this time by the local gas company or an authorized service agent. The tables below and on the following page list the burner manifold gas pressures for the various gas types that can be used with this equipment.

CE Standard Burner Manifold Gas Pressures for Fryers Manufactured After April 1999

Vat Natural Gas Lacq (G20) under 20 mbar 7 7

Natural Gas Groningue * (G25) under 25 mbar 10 10

Natural Gas Groningue (G25) under 20 mbar 10 10

Butane (G30) at 28/30 or 50 mbar 17 17

Propane (G31) under 37 or 50 mbar 20 20

* Belgian G25 = 7,0 mbar (single or dual)

Show 5 more labels / short text on this page
Pressure (mbar) · Single · Dual · Gas · Vat
Page 18 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 18 · click to enlarge
Page 18
Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 18)
Fig. 4
5. Check the programmed temperature thermostat setting. (Refer to the separate M2000 Manual furnished with your unit for the setpoint programming instructions for your particular controller.) 2.5 Converting to Another Gas Type
Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 18)
Fig. 5

Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.6 of this manual. Pro Series H55 gas fryers manufactured for Non-CE countries use different burners for each type gas. The burners in fryers built for propane gas have a special gray-colored coating on the burner tiles to enable them to withstand the higher caloric value of the propane gas. Burners designed for use in propane units may be used in natural gas applications, but not vice versa.

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 18)
Fig. 6

Non-CE Gas Conversion Kits Natural Gas to Propane (LP) Gas Propane (LP) Gas to Natural Gas Full Vat: Part Number 826-1145 Full Vat: Part Number 826-1146 Dual Vat: Part Number 826-1147 Dual Vat: Part Number 826-1148

Units manufactured for export to CE countries are equipped with “universal” burners that may be used with either natural (G20, G25) gas or butane (G30) and propane (G31) gasses.

Page 19 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 19 · click to enlarge
Page 19

CE GAS CONVERSION INSTRUCTIONS 1. Between G20- and G25-type natural gas, adjust the gas pressure at the regulator. (Refer to the CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice. 2. Between a 2nd family (G20 or G25) and a 3rd family gas (G30 butane or G31 propane): a. Change the orifices. b. Adjust the manifold pressure. 3. Affix the new label include with the conversion kit next to the existing rating plate stating that the gas type has been converted. Remove any references to the previously used gas from the existing rating plate. Conversion rating label PN 802-2144. 4. If the destination language changes, replace the labels. Call your local service agency or KES for a label kit. The language of reference will be on the corner of the label.

2.6 After the Fryers Are Positioned At the Frying Station

1. Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the top of the frypot to verify that the unit is level, both side-to-side and front-to-back.

To level fryers, adjust the casters being careful to ensure the fryer(s) are at the proper height in the frying station.

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 19)
Fig. 7
2. Close fryer drain-valve(s) and fill frypot with water to the bottom oil level line. 3. Boil out frypot(s) in accordance with the instructions in Section 5.3.2.1 of this manual. 4. Drain, clean, and fill frypot(s) with cooking oil. (See Equipment Setup and Shutdown Procedures in Chapter 3.)
Page 20 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS
Page 20 · click to enlarge
Page 20

BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS

FINDING YOUR WAY AROUND THE BIPH55 SERIES GAS FRYER

Flue Cap Basket Hangers

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 20)
Fig. 8
Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 20)
Fig. 9
Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 20)
Fig. 10
Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 20)
Fig. 11

TYPICAL CONFIGURATION (BIPH255 SHOWN) NOTE: The appearance of your fryer may differ slightly from that

shown depending upon configuration and date of manufacture.

Show 14 more labels / short text on this page
Flue · Control Panel (M2000 · Top Cap · Computer Shown) · Gas Valve · Gas Valve · Combustion · Blower · Filter Control Handles · Combustion · Drain Handles · Blower · FootPrint Pro Built-in · Filtration Unit
Page 21 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS
Page 21 · click to enlarge
Page 21

3.1 Equipment Setup and Shutdown Procedures

Before lighting the fryer, make sure the fryer is OFF and the frypot drain valve(s) is/are closed. Remove the basket support rack(s), if installed, and fill the frypot to the bottom OIL-LEVEL line.

If solid shortening is being used, make sure it is packed down into the bottom of the frypot. 3.1.1 Setup

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 21)
Fig. 12

DANGER Remove all drops of water from the frypot before filling with oil. Failure to do so will cause spattering of hot liquid when the oil is heated to cooking temperature. 1. Fill the frypot with cooking oil to the bottom OIL LEVEL line located on the rear of the frypot. This will allow for oil expansion as heat is applied. Do not fill cold oil any higher than the bot- tom line; overflow may occur as heat expands the oil.

2. Ensure that the power cord(s) is/are plugged into the appropriate receptacle(s). Verify that the face of the plug is flush with the outlet plate, with no portion of the prongs visible.
3. Ensure that the oil level is at the top OIL LEVEL line when the oil is at its cooking temperature . It may be necessary to add oil to bring the level up to the proper mark, after it has reached cooking temperature .
Page 22 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS
Page 22 · click to enlarge
Page 22

3.1.2 Lighting the Fryer 1. Press the computer ON/OFF switch to the OFF position.

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 22)
Fig. 13

Placing the ON/OFF switch in the OFF position also turns off the gas valve. Wait five minutes before continuing with Step 2, which will also turn on the gas valve.

After placing the ON/OFF switch in the OFF position, turn the gas valve knob to the OFF position. Wait 5 minutes, then turn the knob to the ON postion and proceed with Step 2.

2. Press the computer ON/OFF switch to the ON position. 3. If the burners fail to light, press the ON/OFF switch to the OFF position and wait 60 seconds. Repeat step 2. 4. The fryer will automatically enter the melt cycle mode if the frypot temperature is below 180ºF (82ºC). (NOTE: During the melt cycle, the burners will repeatedly fire for a few seconds, then go out for a longer period.) When the frypot temperature reaches 180ºF (82ºC), the unit will automatically switch to the heating mode. The burners will remain lit until the frypot temperature reaches the programmed cooking temperature. 5. After the burners have been lit for at least 90 seconds, observe the flames through the burner viewing ports located on each side of the combustion air blower.

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 22)
Fig. 14

The optimum burn is a bright orange-red glow. If a blue flame is observed, or if there are dark spots on a burner face, adjust the air gas mixture as follows: On the side of the blower housing opposite the motor is a plate with a locking nut. Loosen the nut enough to allow the plate to be moved, then adjust the position of the plate to open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position and tighten the locking nut.

Page 23 of the Frymaster MPH55 user manual — M2000 COMPUTER
Page 23 · click to enlarge
Page 23

3.1.3 Shutdown For short-term shut down during the workday:

1. Place the computer ON/OFF switch in the OFF position and put the frypot covers in place. When shutting the fryers down at closing time: 1. Place the computer ON/OFF switch in the OFF position to turn the fryer off.

Placing the ON/OFF switch in the OFF position also turns off the gas valve.

After placing the ON/OFF switch in the OFF position, turn the gas valve knob to the OFF position.

ON

ON

OFF

OFF

2. Filter the oil and clean the fryers (See Chapters 4 and 5). 3. Place the frypot covers on the frypots. 3.2 Boiling Out the Frypot To ensure that the frypot is free of any contamination resulting from its manufacture, shipping, and handling during installation, the frypot must be boiled out before first use. Refer to Drain and Clean Frypot (page 5-2) for this procedure.

3.3 Operation

This fryer is equipped with M2000 computers (illustrated below). Refer to the separate M2000 Com- puter Operating Instructions furnished with the fryer for the computer programming and operating procedures.

Frymaster MPH55 — ON diagram (page 23)
Fig. 15

M2000 COMPUTER

Show 4 more labels / short text on this page
For CE Fryers · For Non-CE Fryers · Honeywell · Honeywell
Page 24 of the Frymaster MPH55 user manual — ON
Page 24 · click to enlarge
Page 24

BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 4: FILTRATION INSTRUCTIONS 4.1 Introduction The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in operation. Section 4.3 covers preparation of the filter system for use. Operation of the system is covered in section 4.4.

Frymaster MPH55 — ON diagram (page 24)
Fig. 16

4.2 Draining and Manual Filtering

DANGER When draining oil into a disposal unit or portable filter unit, do not fill above the maximum fill line located on the container. If your fryer is not equipped with a built-in filtration system, the oil must be drained into another suitable container. (For safe, convenient draining and disposal of used oil, Frymaster recommends using the McDonald’s Shortening Disposal Unit (MSDU). The MSDU is available through your local distributor.) 1. Turn the fryer power switch to the OFF position. Screw the drainpipe (provided with your fryer) into the drain valve. Make sure the drainpipe is firmly screwed into the drain valve and that the opening is pointing down.

Page 25 of the Frymaster MPH55 user manual — ON
Page 25 · click to enlarge
Page 25
2. Position a metal container with a sealable cover under the drainpipe. The metal container must be able to withstand the heat of the oil and hold hot liquids. 3. Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food particles, use the Fryer’s Friend (poker-like tool) to clear the blockage.
Frymaster MPH55 — ON diagram (page 25)
Fig. 17

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty. 4. After draining the oil, clean all food particles and residual oil from the frypot. BE CAREFUL, this material may still cause severe burns if it comes in contact with bare skin. 5. Close the drain valve securely and fill the frypot with clean, filtered or fresh oil or solid shortening to the bottom OIL-LEVEL line.

Frymaster MPH55 — ON diagram (page 25)
Fig. 18

4.3 Preparation for Use with Filter Pad

1. Pull the filter pan out from the cabinet and remove the crumb tray, hold-down ring, filter pad (or paper) and filter screen. (See Figure 1) Clean all components with a solution of McDonald’s All Purpose Concentrate and hot water, then dry thoroughly.

a shortening disposal unit (MSDU) to be positioned under the drain.

Frymaster MPH55 — ON diagram (page 25)
Fig. 19

The filter pan is equipped with rollers in rails, much like a kitchen drawer. The pan may be removed for cleaning or to gain access to interior components by lifting the front of the pan to disengage the front rollers, then pulling it forward until the rear rollers clear the rails. The pan cover must not be removed except for cleaning, interior access, or to allow

Page 26 of the Frymaster MPH55 user manual — ON
Page 26 · click to enlarge
Page 26
2. Inspect the filter pan connection fitting to ensure that both O-rings are in good condition. (See Figure 2)
Frymaster MPH55 — ON diagram (page 26)
Fig. 20

3. Then in reverse order, place the metal filter screen in the center of the bottom of the pan, then lay a filter pad over the screen, ensuring that the textured side of the pad is up. Make sure that the pad is in between the embossed ridges of the filter pan then position the hold down ring on top of the pad. If using filter paper, lay a sheet of filter paper over the top of the pan overlapping on all sides. Position the hold down ring over the filter paper and lower the ring into the pan, allowing the paper to fold up and around the ring as it is pushed to the bottom of the pan. Then sprinkle 8- ounces of filter powder over the filter paper. 4. Reinstall the crumb tray at the front of the pan. (See Figure 1) DO NOT use filter powder with the pad! 5. Replace the crumb tray in the filter pan. Push the filter pan back into the fryer, positioning it all the way to the back of the cabinet. The filtration system is now ready for use. 4.4 Operation of the Filter

1. Turn the fryer power OFF. Drain the frypot into the filter pan by rotating the larger handle valves to the right. If necessary, use the Fryer's Friend cleanout rod to clear the drain from inside the frypot.
Frymaster MPH55 — ON diagram (page 26)
Fig. 21
Frymaster MPH55 — ON diagram (page 26)
Fig. 22

Open drain valves by rotating handles to the right.

Frymaster MPH55 — ON diagram (page 26)
Fig. 23
Page 27 of the Frymaster MPH55 user manual — ON
Page 27 · click to enlarge
Page 27
Frymaster MPH55 — ON diagram (page 27)
Fig. 24

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty. 2. After the oil has drained from the frypot, rotate the filter handle to start the pump and begin the filtering process. There may be a slight delay before the pump activates.

Frymaster MPH55 — ON diagram (page 27)
Fig. 25
3. The filter pump draws the oil through the filter pad and circulates it back up to and through the frypot during a 5-minute process called polishing. Polishing cleans the oil by trapping solid particles in the filter pad.
4. After the oil is filtered (about 5 minutes), close the drain valve and allow the fryer to refill. Let the filter pump run 15 to 30 seconds after the oil begins to bubble in the frypot then turn the filter off but rotating the handle up.
Frymaster MPH55 — ON diagram (page 27)
Fig. 26

Filter Pump Reset Switch 5. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not operate.) Turn the fryer ON and allow the oil to reach setpoint.

Page 28 of the Frymaster MPH55 user manual — ON
Page 28 · click to enlarge
Page 28
Frymaster MPH55 — ON diagram (page 28)
Fig. 27
Frymaster MPH55 — ON diagram (page 28)
Fig. 28

4.5 Draining and Disposing of Waste Oil

When your oil has reached the end of its usable life, drain the oil into an appropriate container for transport to the disposal container. Frymaster recommends the use of the McDonald’s Shortening Disposal Unit (MSDU). NOTE: If using an MSDU built before January 2004, the filter pan cover must be removed to allow the unit to be positioned beneath the drain. To remove the lid, lift up on the front edge and pull it straight out of the cabinet. Refer to the documentation furnished with your disposal unit for specific operating instructions. If a shortening disposal unit is not available, allow the oil to cool to 100°F (38°C), then drain the oil into a metal stockpot or similar metal container. When draining is finished, close the fryer drain valve securely.

Frymaster MPH55 — ON diagram (page 28)
Fig. 29
Page 29 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE
Page 29 · click to enlarge
Page 29

BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE

5.1 Fryer Preventive Maintenance Checks and Service

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE diagram (page 29)
Fig. 30

5.2 DAILY CHECKS AND SERVICE 5.2.1 Inspect Fryer and Accessories for Damage Look for loose or frayed wires and cords, leaks, foreign material in frypot or inside cabinet, and any other indications that the fryer and accessories are not ready and safe for operation. 5.2.2 Clean Fryer Cabinet Inside and Out Clean inside the fryer cabinet with dry, clean cloth. Wipe all accessible metal surfaces and compo- nents to remove accumulations of oil and dust. Clean the outside of the fryer cabinet with a clean, damp cloth soaked with McDonald’s All Purpose Concentrate, removing oil, dust, and lint from the fryer cabinet. Wipe with a clean, damp cloth.

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE diagram (page 29)
Fig. 31
Page 30 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE
Page 30 · click to enlarge
Page 30
Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE diagram (page 30)
Fig. 32

There are no periodic preventive maintenance checks and services required for your FootPrint Pro Filtration System other than daily cleaning of the filter pan with a solution of hot water and McDonald’s All Purpose Concentrate. If you notice that the system is pumping slowly or not at all, verify that the filter pan screen is on the bottom of the filter pan, with the pad on top of the screen. Verify that the two O-ring(s) on the fitting at the right front of the filter pan are present and in good condition. 5.3 WEEKLY CHECKS AND SERVICE 5.3.1 Clean Behind Fryers Clean behind fryers in accordance with the procedure detailed in maintenance requirement card (MRC) 14A. 5.3.2 Cleaning the Frypot

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE diagram (page 30)
Fig. 33

5.3.2.1 Boiling Out the Frypot Before the fryer is first used, it should be boiled out to ensure that residue from the manufacturing process has been eliminated. Also, during normal usage of your fryer, a deposit of carbonized oil or shortening will gradually form on the inside of the frypot. This deposit must be periodically removed by following the boil-out procedure contained in maintenance requirement card (MRC) 14A to maintain your fryer’s efficiency. Refer to the separate M2000 Computer Operating Instructions fur- nished with the fryer for specific details on setting up the computer for boil-out operation.

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE diagram (page 30)
Fig. 34
Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE diagram (page 30)
Fig. 35
Page 31 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE
Page 31 · click to enlarge
Page 31

DANGER Ensure that the frypot is completely free of water before filling with oil or shortening. When the oil or shortening is heated to cooking temperature, water in the frypot will cause splattering. 5.3.3 Clean Filter Pan, Detachable Parts and Accessories As with the frypot, a deposit of carbonized oil or shortening will accumulate on the filter pan and detachable parts and accessories such as baskets, sediment trays, or fishplates. Wipe the filter pan and all detachable parts and accessories with a clean dry cloth. Use a cloth dampened with a solution of McDonald’s All Purpose Concentrate to remove accumulated carbonized oil. Rinse and thoroughly dry each part. DO NOT use steel wool or abrasive pads to clean these parts. The scratches that result from such scrubbing make subsequent cleanings more difficult. 5.4 MONTHLY CHECKS AND SERVICE 5.4.1 Check M2000 Computer Set Point Accuracy 1. Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the fryer temperature-sensing probe. 2. When the computer display shows a series of dashes “ ” or a product name (indicating that the frypot contents are within the cooking range), press the switch once to display the temperature of the oil or shortening as sensed by the temperature probe. 3. Press the switch twice to display the set point. 4. Note the temperature on the thermometer or pyrometer. Actual temperature and pyrometer readings should be within ± 5ºF (3ºC) of each other. If not, contact a Factory Authorized Service Center for assistance. 5.5 QUARTERLY CHECKS AND SERVICE

5.5.1 Clean Combustion Air Blower Assembly 1. Disconnect the blower wiring harness and remove the four blower mounting nuts. (See Figure 1 on next page)

Page 32 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE
Page 32 · click to enlarge
Page 32

Blower assembly mounting nuts

Frymaster MPH55 — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE diagram (page 32)
Fig. 36
2. Remove the three fasteners that secure the blower motor assembly to the blower housing, and separate the two components. (See Figure 2)

Remove these fasteners.

3. Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or detergent on the blower wheel and the blower housing. Allow it to soak for five minutes. Rinse the wheel and housing with hot tap water, then dry with a clean cloth. (See Figure 3)

Wrap the motor and wires

with plastic wrap or a

plastic bag.

Wiring connection · Blower Housing · Blower Wheel

Page 33 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 5: PREVENTIVE MAINTENANCE
Page 33 · click to enlarge
Page 33
4. Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor assembly and blower housing. Reinstall the blower assembly in the fryer. 5. Reinstall the blower shield or shield assembly. 6. Light the fryer in accordance with the procedure described in Chapter 3, Section 3.1. 7. After the burners have been lit for at least 90 seconds, observe the flames through the burner viewing ports located on each side of the combustion air blower. (See Figure 4)

Left Viewing Port is Behind

Motor (NOTEBlower

for clarity.)

The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the applicable table on page 2-7 and the burners display a bright orange-red glow. If a blue flame is observed, or if there are dark spots on a burner face, the air/gas mixture requires adjustment. On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position and tighten the locking nut(s).

TYPICAL BLOWER ASSEMBLY SOME CE BLOWER ASSEMBLIES MAY BE CONFIGURED THIS WAY

Right Viewing · shield omitted · Port

Page 34 of the Frymaster MPH55 user manual — 5.6 SEMI-ANNUAL CHECKS AND SERVICE
Page 34 · click to enlarge
Page 34

5.6 SEMI-ANNUAL CHECKS AND SERVICE

5.6.1 Clean Gas Valve Vent Tube

1. Set the fryer power switch and the gas valve to the OFF position.
2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease in removal.
3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any obstruction. 4. Remove the wire and blow through the tube to ensure it is clear.
5. Reinstall the tube and bend it so that the opening is pointing downward. 5.6.2 Check Burner Manifold Pressure
  • DANGER This task should be performed by qualified service personnel only. Contact your FASC to arrange this service. 5.7 Annual/Periodic System Inspection This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program. Frymaster recommends that a Factory Authorized Service Technician inspect this appliance at least annually as follows: 5.7.1 Fryer
  • Inspect the cabinet inside and out, front and rear for excessive oil.
  • Verify that debris or accumulations of solidified oil or shortening do not obstruct the flue opening.
  • Verify that burners and associated components (i.e. gas valves, pilot assemblies, ignitors, etc.) are in good condition and functioning properly. Inspect all gas connections for leaks and verify that all connections are properly tightened.
  • Verify that the burner manifold pressure is in accordance with that specified on the appliance’s rating plate.
  • Verify that the temperature and high-limit probes are properly connected, tightened and functioning properly, and that probe guards are present and properly installed.
Page 35 of the Frymaster MPH55 user manual — 5.6 SEMI-ANNUAL CHECKS AND SERVICE
Page 35 · click to enlarge
Page 35
  • Verify that component box components (i.e. computer, transformers, relays, interface boards, etc.) are in good condition and free from oil and other debris. Inspect the component box wiring and verify that connections are tight and that wiring is in good condition.
  • Verify that all safety features (i.e. drain safety switches, reset switches, etc.) are present and functioning properly.
  • Verify that the frypot/cookpot is in good condition and free of leaks and that the frypot/cookpot insulation is in serviceable condition.
  • Verify that wiring harnesses and connections are tight and in good condition. 5.7.2 Built-In Filtration System
  • Inspect all oil-return and drain lines for leaks and verify that all connections are tight.
  • Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.
  • Verify that all O-rings and seals are present and in good condition. Replace O-rings and seals if worn or damaged.
  • Check filtration system integrity as follows:

− Verify that filter pan cover is present and properly installed.

− With the filter pan empty, place each oil return handle, one at a time, in the ON position.

Verify that the pump activates and that bubbles appear in the cooking oil of the associated frypot.

− Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return microswitches. No air bubbles should be visible in any frypot

− Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to

350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all oil to return to the frypot (indicated by bubbles in the cooking oil). Return the oil return handle to the OFF position. The frypot should have refilled in ap- proximately 2 minutes and 30 seconds.

Page 36 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 6: OPERATOR TROUBLESHOOTING
Page 36 · click to enlarge
Page 36

BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 6: OPERATOR TROUBLESHOOTING

6.1 Introduction

This chapter provides an easy reference guide to some of the common problems that may occur during the operation of your equipment. The troubleshooting guides that follow are intended to help you correct, or at least accurately diagnose, problems with your equipment. Although the chapter covers the most common problems reported, you may encounter problems that are not covered. In such instances, the Frymaster Technical Services staff will make every effort to help you identify and resolve the problem. When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through to the most complex. Most importantly, always try to establish a clear idea of why a problem has occurred. Part of your corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections while you’re at it. If a fuse continues to blow, find out why. Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system. If you are in doubt as to the proper action to take, do not hesitate to call the Frymaster Technical Service Department or your local Frymaster Factory Authorized Service Center for assistance. Before calling a servicer or the Frymaster HOTLINE (1-800-551-8633):

  • Verify that electrical cords are plugged in and that circuit breakers are on.
  • Verify that gas line quick-disconnects are properly connected.
  • Verify that any gas line cutoff valves are open.
  • Verify that frypot drain valves are fully closed.
Page 37 of the Frymaster MPH55 user manual — BIPH55 / MPH55 SERIES GAS FRYER CHAPTER 6: OPERATOR TROUBLESHOOTING
Page 37 · click to enlarge
Page 37

6.2 Troubleshooting Fryers 6.2.1 Computer and Heating Problems PROBLEM PROBABLE CAUSES CORRECTIVE ACTION

A. Verify that the fryer is plugged in

A. No power to fryer.

and that the circuit breaker is not tripped. B. Damaged computer wiring

B. Call FASC.

harness.

C. Failed Computer C. Call FASC.

D. If any component in the power supply system (including the transformer and interface board) fail, power will not be supplied to the computer and it will not function. Determining which component has failed is beyond the scope of operator troubleshooting. Call FASC. A. Drain valve not fully closed. A. Press the ON/OFF switch off, close the drain valve(s) completely, then press the ON/OFF switch on.

No display on the

computer.

D. Power supply component or interface board has failed.

B. Gas valve is not turned on. B. Turn the gas valve knob to the ON position.

C. Verify that any in-line manual shut off valve is open. Verify that gas main cut off valve is open.

C. Manual gas shut off valve closed.

Fryer does not heat.

D. Verify that the quick-disconnect fitting on the flexible gas line is firmly connected to the fryer.

D. Improperly connected quick-

disconnect fitting on gas line.

E. Verify that combustion air blower is running. If not, call FASC for service. If combustion air blower is functional, clean and adjust per instructions in Chapter 5 of this manual.

E. Obstructed or failed combustion

air blower.

F. Damaged computer wiring

F. Call FASC.

harness or connector.

normally, but recovery is slow

Dirty or obstructed combustion air blower.

Clean and adjust per instructions

in Chapter 5 of this manual.

when cooking.

Fryer is operating

Page 38 of the Frymaster MPH55 user manual — Problem Probable Causes Corrective Action
Page 38 · click to enlarge
Page 38

PROBLEM PROBABLE CAUSES CORRECTIVE ACTION A. Dirty or obstructed combustion air

A. Clean and adjust per instructions

blower.

in Chapter 5 of this manual.

normally, but produces a popping sound when burners

B. Dirty or obstructed gas valve vent

B. Clean per instructions in Chapter

ignite.

tube (non-CE fryers only).

5 of this manual.

C. Malfunctioning combustion air

C. If blower is slow to come up to

speed, contact FASC for service. Computer will not

blower.

mode or some buttons do not

Failed computer. Call FASC.

actuate.

Heat indicator is on

and blower is running, but burner

Blown fuse on interface board or ignition module. Replace fuse.

will not ignite.

6.3 Error Messages and Display Problems

Problem Probable Causes Corrective Action

M2000 computers may be programmed to display in either Fahrenheit or Celsius. Refer to the separate M2000 Computer Operation Manual for instructions on changing the display.

M2000 display is in wrong temperature scale (Fahrenheit or

Incorrect display option programmed.

Celsius).

This display will appear only if the fryer is in the non-dedicated mode and the frypot temperature rises 15° (8°C) or more above the programmed setpoint. This indicates a problem with the temperature control circuitry. Turn the fryer off and call FASC.

shows HI. Fryer is 15ºF (8ºC) above setpoint.

This in an indication of a malfunction in the temperature control circuitry, including a failure of the high limit thermostat. Shut the fryer down immediately and call FASC.

Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).

shows HOT.

Show 4 more labels / short text on this page
Fryer is operating · go into program · M2000 display · M2000 display
Page 39 of the Frymaster MPH55 user manual — Problem Probable Causes Corrective Action
Page 39 · click to enlarge
Page 39

Problem Probable Causes Corrective Action

This display is normal when the fryer is first turned on and may appear for a short while if a large batch of frozen product is added to the frypot. If the display never goes out, the fryer is not heating. Shut the fryer down and call FASC.

M2000 display shows LOW TEMP.

Frypot temperature is between 180°F (82°C) and 315°F (157°C).

This indicates a problem within the temperature measuring circuitry that is beyond the scope of operator troubleshooting. Shut the fryer down and call FASC.

M2000 display shows PROBE

Problem with the temperature measuring circuitry including the probe.

FAILURE.

This indicates that the fryer is not heating. It is displayed if the fryer loses its ability to heat oil. It is also displayed when the oil temperature is above 450°F (232°C) and the high-limit thermostat has opened, halting the heating of the oil. Verify that the drain valves are fully closed. If this does not correct the problem, call your FASC.

M2000 display shows IGNITION

Open drain valve, failed computer, failed transformer, open high-limit thermostat.

FAILURE.

This is displayed only during a test of the hi-limit circuit and indicates that the hi-limit has opened properly. Display shows

M2000 display shows HI-LIMIT. Computer in hi-limit test mode.

cycles on and off

normally, but burners will not light and blower is

Failed computer or damaged computer wiring harness. Call FASC.

not running.

Heat indicator off upon initial startup.

Failed computer, damaged wiring harness or connector Call FASC

with alarm sounding.

Show 4 more labels / short text on this page
, heating indicator · Display shows · , · or
Page 40 of the Frymaster MPH55 user manual — OR
Page 40 · click to enlarge
Page 40

Problem Probable Causes Corrective Action

This is displayed only during a test of the hi-limit circuit and indicates that the hi-limit has failed. DO NOT OPERATE THE FRYER! Call FASC. 6.4 Troubleshooting the Built-in Filtration System

M2000 display shows HI 2 BAD. Computer in hi-limit test mode.

PROBLEM PROBABLE CAUSES CORRECTIVE ACTION A. Thermal overload switch has

A. If the pump runs normally after

tripped on an overheated motor.

resetting the thermal overload switch, the pump was overheated.

Test: If the pump stopped suddenly during the filtering process, especially if after several filtering cycles, the pump motor has probably overheated. Place the filter handle in the OFF position, allow the pump to cool for at least 45 minutes, and then press the reset button on the pump motor. Attempt to activate the pump.

Always filter with the cooking oil/shortening at or near frying temperature. Allow the pump motor to cool off for about ten minutes after filtering two full frypots one after the other. Check the filter pad between filtering. Replace the pad if there is a large accumulation of sediment. B. Failed filter handle microswitch.

Pump won’t start.

OR

filtering.

Test: If this is a multi-pot fryer, attempt to operate the pump using a different handle. If the pump starts, the handle microswitch is either out of alignment or has failed. When the handle is placed in the ON position, the lever on the microswitch should be firmly pressed against the switch. If so, the switch has failed. If not, the switch is loose and/or misaligned.

B. If the switch is loose, tighten the

nuts and bolts holding it in place, ensuring that when the handle is placed in the ON position, the lever on the microswitch is pressed firmly against the switch.

If the switch has failed, call FASC.

Pump stops during

Page 41 of the Frymaster MPH55 user manual — PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
Page 41 · click to enlarge
Page 41

PROBLEM PROBABLE CAUSES CORRECTIVE ACTION

C. Blockage in filter pump. Test: Close the drain valve. Place the filter handle in the OFF position, allow the pump to cool for at least 45 minutes, and then press the reset button on the pump motor. Pull the filter pan from the unit. Activate the pump. If the pump motor hums and then stops, the pump is blocked. Also if air or bubbling oil comes out of the rear flush port, there is a blockage in the filter pan suction tube.

C. Pump blockages are usually

caused by sediment build-up in the pump due to improperly sized or installed filter pad and failure to use the crumb screen. Use a thin flexible wire to remove the blockage. If the blockage cannot be removed, call FASC. Ensure that filter pad is of the proper size and is installed properly, and that the crumb screen is used.

A. To properly filter, the oil should

be at or near 350°F (177°C). At temperatures lower than this, the oil becomes too thick to pass through the filter medium easily, resulting in much slower oil return and eventual overheating of the filter pump motor. Filter Pump starts, but no transfer takes

A. Cooking oil is too cold for

filtering.

B. Improperly installed or prepared

filter pan components.

B. Remove the oil from the filter pan

place or the oil return is very slow.

Test: Close the drain valve. Move the filter handle to the OFF position, pull the filter pan from the unit. Move the filter handle to the ON position. If a strong stream of air is being pumped out of the oil return port, the problem is with the filter pan components.

and replace the filter pad, ensuring that the filter screen is in place under the pad. If this does not correct the problem, the filter suction tube is probably blocked. Remove the blockage using a thin, flexible wire. If unable to remove the blockage, call FASC.

Continued from · Previous page

Page 42 of the Frymaster MPH55 user manual — OR
Page 42 · click to enlarge
Page 42

6.6 Replacing the Controller or Controller Wiring Harness

1. Disconnect the fryer from the electrical power supply. 2. The controller bezel is held in place by tabs at the top and bottom. Slide the bezel up to disengage the lower tabs. Then slide the bezel down to disengage the upper tabs. 3. Remove the top two screws in the upper corners of the control panel. 4. Hinge the controller down. Allow it to rest on its hinge tabs to access the 15-pin connector on the back.

Wiring Harness Connector Ground Wire

Frymaster MPH55 — OR diagram (page 42)
Fig. 37

5. Disconnect the 15-pin wiring harness from the back of the controller and, if replacing the harness, disconnect it from the interface board. 6. Use a 5/16” nut driver (P/N 802-0352) to remove the nut and green ground wire from the back of the controller. 7. Remove the controller by lifting it up and out from the hinge slots in the control panel frame. 8. Re-hinge the NEW controller by inserting the tabs on the bottom into the slots on the control frame panel and allow it to rest on the hinge tabs. 9. If replacing the 15-pin connector, do so now. Plug the new 15-pin wiring harness into the interface board with the metal ring on the controller-end of the connector. 10. Connect the 15-pin connector and the green ground wire to the new controller. When the connector is completely engaged, the clips on either side of the connector will snap into place. 11. Move the controller into the closed position against the control panel frame and replace the screws in the top corners. 12. Insert the top tabs on the bezel into the slots on the underside of the top cap. Slide the bezel down to engage the lower tabs in the lower slots.

Ignition Module

Page 43 of the Frymaster MPH55 user manual — THIS PAGE INTENTIONALLY LEFT BLANK
Page 43 · click to enlarge
Page 43

THIS PAGE INTENTIONALLY LEFT BLANK

Page 44 of the Frymaster MPH55 user manual — PRINTED IN THE UNITED STATES SERVICE HOTLINE
Page 44 · click to enlarge
Page 44
Frymaster MPH55 — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 44)
Fig. 38
Frymaster MPH55 — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 44)
Fig. 39

Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000

Shipping Address8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135

PRINTED IN THE UNITED STATES SERVICE HOTLINE

1-800-551-8633 819-6087 OCT 2005

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No display on the computer.A. No power to fryer.A. Verify that the fryer is plugged in and that the circuit breaker is not tripped. p.37
No display on the computer.B. Damaged computer wiring harness.B. Call FASC. p.37
No display on the computer.C. Failed ComputerC. Call FASC. p.37
No display on the computer.D. Power supply component or interface board has failed.D. If any component in the power supply system (including the transformer and interface board) fail, power will not be supplied to the computer and it will not function. Determining which component has failed is beyond the scope of operator troubleshooting. Call FASC. p.37
Fryer does not heat.A. Drain valve not fully closed.A. Press the ON/OFF switch off, close the drain valve(s) completely, then press the ON/OFF switch on. p.37
Fryer does not heat.B. Gas valve is not turned on.B. Turn the gas valve knob to the ON position. p.37
Fryer does not heat.C. Manual gas shut off valve closed.C. Verify that any in-line manual shut off valve is open. Verify that gas main cut off valve is open. p.37
Fryer does not heat.D. Improperly connected quick- disconnect fitting on gas line.D. Verify that the quick-disconnect fitting on the flexible gas line is firmly connected to the fryer. p.37
Fryer does not heat.E. Obstructed or failed combustion air blower.E. Verify that combustion air blower is running. If not, call FASC for service. If combustion air blower is functional, clean and adjust per instructions in Chapter 5 of this manual. p.37
Fryer does not heat.F. Damaged computer wiring harness or connector.F. Call FASC. p.37
Fryer is operating normally, but recovery is slow when cooking.Dirty or obstructed combustion air blower.Clean and adjust per instructions in Chapter 5 of this manual. p.37
Fryer is operating normally, but produces a popping sound when burners ignite.A. Dirty or obstructed combustion air blower.A. Clean and adjust per instructions in Chapter 5 of this manual. p.38
Fryer is operating normally, but produces a popping sound when burners ignite.B. Dirty or obstructed gas valve vent tube (non-CE fryers only).B. Clean per instructions in Chapter 5 of this manual. p.38
Fryer is operating normally, but produces a popping sound when burners ignite.C. Malfunctioning combustion air blower.C. If blower is slow to come up to speed, contact FASC for service. p.38
Computer will not go into program mode or some buttons do not actuate.Failed computer.Call FASC. p.38
Heat indicator is on and blower is running, but burner will not ignite.Blown fuse on interface board or ignition module.Replace fuse. p.38
M2000 display is in wrong temperature scale (Fahrenheit or Celsius).Incorrect display option programmed.M2000 computers may be programmed to display in either Fahrenheit or Celsius. Refer to the separate M2000 Computer Operation Manual for instructions on changing the display. p.38
M2000 display shows HI.Fryer is 15ºF (8ºC) above setpoint.This display will appear only if the fryer is in the non-dedicated mode and the frypot temperature rises 15° (8°C) or more above the programmed setpoint. This indicates a problem with the temperature control circuitry. Turn the fryer off and call FASC. p.38
M2000 display shows HOT.Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).This in an indication of a malfunction in the temperature control circuitry, including a failure of the high limit thermostat. Shut the fryer down immediately and call FASC. p.38
M2000 display shows LOW TEMP.Frypot temperature is between 180°F (82°C) and 315°F (157°C).This display is normal when the fryer is first turned on and may appear for a short while if a large batch of frozen product is added to the frypot. If the display never goes out, the fryer is not heating. Shut the fryer down and call FASC. p.39
M2000 display shows PROBE FAILURE.Problem with the temperature measuring circuitry including the probe.This indicates a problem within the temperature measuring circuitry that is beyond the scope of operator troubleshooting. Shut the fryer down and call FASC. p.39
M2000 display shows IGNITION FAILURE.Open drain valve, failed computer, failed transformer, open high-limit thermostat.This indicates that the fryer is not heating. It is displayed if the fryer loses its ability to heat oil. It is also displayed when the oil temperature is above 450°F (232°C) and the high-limit thermostat has opened, halting the heating of the oil. Verify that the drain valves are fully closed. If this does not correct the problem, call your FASC. p.39
M2000 display shows HI-LIMIT.Computer in hi-limit test mode.This is displayed only during a test of the hi-limit circuit and indicates that the hi-limit has opened properly. p.39
Display shows , heating indicator cycles on and off normally, but burners will not light and blower is not running.Failed computer or damaged computer wiring harness.Call FASC. p.39
Heat indicator off upon initial startup. Display shows , or with alarm sounding.Failed computer, damaged wiring harness or connectorCall FASC p.39
M2000 display shows HI 2 BAD.Computer in hi-limit test mode.This is displayed only during a test of the hi-limit circuit and indicates that the hi-limit has failed. DO NOT OPERATE THE FRYER! Call FASC. p.40
Pump won’t start. OR Pump stops during filtering.A. Thermal overload switch has tripped on an overheated motor. Test: If the pump stopped suddenly during the filtering process, especially if after several filtering cycles, the pump motor has probably overheated. Place the filter handle in the OFF position, allow the pump to cool for at least 45 minutes, and then press the reset button on the pump motor. Attempt to activate the pump.A. If the pump runs normally after resetting the thermal overload switch, the pump was overheated. Always filter with the cooking oil/shortening at or near frying temperature. Allow the pump motor to cool off for about ten minutes after filtering two full frypots one after the other. Check the filter pad between filtering. Replace the pad if there is a large accumulation of sediment. p.40
Pump won’t start. OR Pump stops during filtering.B. Failed filter handle microswitch. Test: If this is a multi-pot fryer, attempt to operate the pump using a different handle. If the pump starts, the handle microswitch is either out of alignment or has failed. When the handle is placed in the ON position, the lever on the microswitch should be firmly pressed against the switch. If so, the switch has failed. If not, the switch is loose and/or misaligned.B. If the switch is loose, tighten the nuts and bolts holding it in place, ensuring that when the handle is placed in the ON position, the lever on the microswitch is pressed firmly against the switch. If the switch has failed, call FASC. p.40
Continued from Previous pageC. Blockage in filter pump. Test: Close the drain valve. Place the filter handle in the OFF position, allow the pump to cool for at least 45 minutes, and then press the reset button on the pump motor. Pull the filter pan from the unit. Activate the pump. If the pump motor hums and then stops, the pump is blocked. Also if air or bubbling oil comes out of the rear flush port, there is a blockage in the filter pan suction tube.C. Pump blockages are usually caused by sediment build-up in the pump due to improperly sized or installed filter pad and failure to use the crumb screen. Use a thin flexible wire to remove the blockage. If the blockage cannot be removed, call FASC. Ensure that filter pad is of the proper size and is installed properly, and that the crumb screen is used. p.41
Filter Pump starts, but no transfer takes place or the oil return is very slow.A. Cooking oil is too cold for filtering.A. To properly filter, the oil should be at or near 350°F (177°C). At temperatures lower than this, the oil becomes too thick to pass through the filter medium easily, resulting in much slower oil return and eventual overheating of the filter pump motor. p.41
Filter Pump starts, but no transfer takes place or the oil return is very slow.B. Improperly installed or prepared filter pan components. Test: Close the drain valve. Move the filter handle to the OFF position, pull the filter pan from the unit. Move the filter handle to the ON position. If a strong stream of air is being pumped out of the oil return port, the problem is with the filter pan components.B. Remove the oil from the filter pan and replace the filter pad, ensuring that the filter screen is in place under the pad. If this does not correct the problem, the filter suction tube is probably blocked. Remove the blockage using a thin, flexible wire. If unable to remove the blockage, call FASC. p.41

Ask about the Frymaster MPH55

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster MPH55

Be the first to ask — other owners or our team will answer.

Original document

Frymaster MPH55 manual PDF

44 pages·1.5 MB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…