LOV LOV ™ FRYER Generation II FRYER Generation II


The LOV ™ Systems 2
M3000 12
RTI-equipped Systems 31
Board Replacement 38
Wiring Diagrams 41
Pin Positions 44
Frymaster and Dean Technical Service 8700 Line Ave, Shreveport, LA 71106 Service Hotline: 800-551-8633 Website: www.frymaster.com *8196506*
Edition


JIB (behind right door)
The LOV™ fryer.
The Low Oil Volume (LOV™) fryer is a McDonald’s-only, feature-laden version of the electric RE fryer or gas H55 fryer. The enhancements found on the LOV™ fryer include:



Oil Return/Top Off Slots
Ports and sensors inside a gas frypot. Oil return/ top off is at bottom rear of cool zone.
Ports and sensors inside an electric frypot.
The core of the system is the automatic top-off board, which senses when the oil level is low and fi lls the pot to the top line.
Top off will continue on the next vat if needed. The system is not suited to fi lling the frypot when it is empty and there are safeguards to prevent it from activating when the fryer is cold and the oil is rest- ing at the lower position.
The oil level is monitored by an RTD (Resistance Temperature Detector) sensor in the frypot at the upper oil level. The oil is moved to the pot from a reservoir, called a JIB (Jug In Box), to the frypot with a pump.
The system is not active until the oil in the frypot reaches setpoint. That temperature is monitored by the temperature probe. The activation of the system is handled by the fryer’s computer, the M3000. The automatic top off system is also inactive during fi lter dispose cycles.
A circuit board, the ATO (Automatic Top Off), is located inside a box behind the JIB. It monitors the oil-level RTD and activates the pump when it senses an oil temperature drop of 60°F (33°C) below set- point, indicating the oil has moved away from the sensor. The ATO sends a signal to the MIB (Manual Interface Board), which then sends a signal to the AIF to open the actuator on the return valve of the frypot to be topped off.
The system works the same in McDonald’s gas and electric LOV™ systems.
The level of the reservoir, or JIB, is monitored by the ATO and the M3000 computer. If a low oil condition is not rectifi ed with two top off attempts or within 6 minutes, the low JIB light is illuminated on the front of the fryer. It will stay illuminated until the JIB is replaced and the orange button has been pressed and held to reset the light (see page 34).
Once the actuator has opened the return valve, oil is pumped into the vat for a specifi ed amount of time (approximately 60 seconds). When the ATO RTD detects a temperature within 55°F (30°C) of set- point, it is satisfi ed and the actuator closes the valve.


The ATO board positioned underneath the LON gateway controls the top off of the fry pots.
The pump that moves oil from the reser- voir to the frypots is visible above.



The reservoir, or JIB, rests behind the right door of the fryer. A light on the front of the fryer illuminates when the jug is empty.
The ATO board is positioned under the LON gateway in a box with a transformer that provides power to the board. The LON gateway must be removed to access the ATO board.
Transformer


The auto fi ltration system is controlled by the M3000 computer, the AIF (Automatic Intermittent Filtration) board and the MIB (Manual Interface Board). The fi ltration is made hands-off by actuators operating the drain and return valves.

The computer is programmable, and it allows fi lter cycles to be launched after a set number of cook cycles and a prescribed elapsed time.
The system can be set to lock out automatic fi ltration during busy times, such as the lunch rush.
An AIF board is mounted under each fry vat.
The fryer prompts for fi ltration by illuminating a blue LED on the front and a text prompt on the computer. The operator can say no; cooking can continue.
Responding “yes” leads to communication between the MIB and the AIF boards. The MIB controls and oversees the fi ltration; the AIF board operates the actuators, which open and close the valves.
The MIB is in the fryer cabinet. It is partially covered by a sheet metal cover and the LED display is visible. Buttons behind the cover allow limited manual operation of the system and its valves. The cover should be reinstalled after service.
The LED displays codes that can be used to diagnose failures (see chart on page 45).
(1) Responding to the Blue LED fi lter prompt with “yes” starts a fi lter cycle that lasts about as long as a cook cycle (approx. 4 minutes). Communication between the M3000 computer, the manual interface (MIB board), and the automatic intermittent fi ltration (AIF board) handle the process.


(2) Actuators open and close the drain valve and return valve, (3) emptying and refi lling the frypot.




Mode Display Shows status (auto or manual) vat number (when operating valves manuals) and dis- plays error codes.

Reset Resets system, ensures all valves are closed.
Drain Opens and closes drain valves in manual mode. Vat Selection Selects vat for manual operation of valves.
Return Opens and closes return valves and turns on fi lter pump in manual mode.
Manual/Auto Switches fryer from auto to manual operation.
The MIB board.

Manual — Used to toggle between automatic and manual fi ltration mode. The unit must be in manual mode for the other MIB buttons to operate.
Select — Used to scroll through the vats, which are shown numerically in the LED.
Drain — Used to open and close the drain valve of the vat indicated on the display. When pressed an LED on the button indicates activity: slow blink, awaiting response from AIF; LED illuminated constantly, drain open; no illumination, drain closed.
The MIB is mounted behind the left door. See arrow.
Return — Used to open and close the return valve on the vat indicated on the display. It also controls the pump. When pressed an LED on the button indicates activity:
The pump operates with a momentary switch. Pressing and holding the return button after the valve is open activates the fi lter pump. Releasing the button deactivates the pump.
blink: awaiting response from AIF, LED illuminated constantly: drain open, no illumination: drain closed.
The mode display on the face of the MIB board displays a range of letters, which indicate activity or an error. These codes are listed on the next page.

1L, 1r - 5L, 5r — Numbers correspond to vats: “L” indicates the left side of a split vat. “r” indicates a full vat or the right side of a split vat.
P — Pan switch: fi lter pan is not in place or not sensed. Auto Filtration disabled.
r — Reset: r alternating with a vat number indicates that the MIB board is resetting. If r is displayed without alternating with a vat number, a problem may exist with the MIB board itself.
A — Auto mode: auto fi ltration enabled.
E — Drain or return valve not in desired state: display alternates between E and vat number. (Ensure actuator is plugged in and in the home position.)
Three horizontal lines — temperature sensor: sensor did not detect that the vat was full during auto fi ltration.
n — Network Error: An “n” displays for 10 seconds if no communication is received from the cooking computer within ten seconds after a power on.



Press the M button, which switches the board to manual. The display becomes the number of the vat to be controlled manually.
Press the vat selector button until the desired vat number is displayed.
Press the drain button to drain the oil or the press and hold the return button to return oil to the vat displayed. Opening the drain and pressing and holding the return button after valve is open allows fi ltration.
Pressing the M button again returns the board to automatic mode.



The oil return sensor is a device that is used to prevent dry fi ring of the burners. The sensor looks similar to a high limit. The sensors are energized when the computer is powered on with a soft on. The sensor heats up and detects the oil around it. During fi ltration when the oil is drained, it senses the difference between the oil and air. It is controlled with a board located next to the interface board (right) and a separate egg shaped plastic device (far right) that contains additional electronics. Use care when working with the sensor as temperatures may reach as high as 500°F (260°C).


The oil return sensor is controlled by a small green board and the electronics inside the plastic, egg-shaped device shown above to prevent dry fi ring.

If oil is surrounding the heater, the oil will prevent the heater from ever reaching its setpoint. Once oil is removed during fi ltration, the heater reaches setpoint and cycles a thermostat every four seconds. Since the cycle is only four seconds long, the seven second delay is not made and the gas valve won’t open.
The 120VAC is on T2 in the control box traveling in on pin 11 of J3 and out pin 7 on J1 (DV) or pin 7 on J3 (FV).
Low temp but no call for heat (heat light), Stuck in melt cycle with no call for heat, Filter error (IS VAT FULL? IS VAT FULL?) with oil in the fi lter pan (no oil in the vat).
If the computer doesn’t exit melt cycle or continues to display low temp and does not heat, ensure that the gas supply, gas valve, and other components are working properly. If no heat lamp illuminates because no call for heat is initiated, check the following (see diagram below):
Power to oil sensor (from previous basket lift relay on interface board K1(DV) or K4 (FV)). Check pin 7 on J1 (DV) or pin 7 on J3 (FV) for 120VAC. Power to heater/relay coil on relay board. Check voltage to the coil on pins 8 and 1 to ensure that 120VAC is present with oil in the vat. If the vat is empty, the power will cycle 4 seconds on, 4 seconds off. Check between pin 3 and 2; 5VDC for air and 0VDC for oil. A common message for a shorted harness or issue is IS DRAIN CLEAR? IS DRAIN CLEAR? with oil in the fi lter pan. Check ground on pin 2 on relay board to stud for a secure ground. Check AIF communication harness. Interrupted communication will prevent the fryer from heating. If the oil level sensor is cycling 4 sec. on/off and oil is surrounding the sensor, the sensor may have a carbon build up that is self insulating the sensor. Use a no scratch pad to remove carbon build up.
Black (To J1 Pin 7 (DV)
or J3 Pin 7 (FV))
120V Fixed Setpoint Temp. Control
Heater (350 ohms US) (1325 ohms Intl)
White (To T2 Terminal Block
120V (US) 230V (Intl) 40W Heater w/ Thermocouple
Line Voltage In From
Oil Level Sensor (Basket Lift) Relay on
24VAC from Interface Board through High Limit (Ign. Module
6 To AIF Board J2 Pin 9 DV
or 10 FV (AIF Oil Signal)
Time Delay Relay Board DPDT 7sec. Delay on Make

Overview
and Navigation Buttons Cook Cycle and Selection Buttons
Filter, Temp, Info, Programming
Lamp LED Display LED Display

ON/OFF ON/OFF Product Buttons
The M3000 computer retains the one-button ease of the M2000 and M100B, combining it with the utility of 40-product menu capability. It will operate with electric and gas fryers, both full- and split- vat.
On single product vats, press any of the cook cycle buttons to begin cooking. On multi-product vats, press a product button, and then a cook cycle button under the display showing the desired product name.
For example, a typical M3000 computer on a 3-vat fry station will display FR FRIES FR FRIES. Pressing one of the cook cycle buttons will begin a cook cycle for French fries.
The chicken/fi llet station will usually display dashed lines [ ]. Pressing the product button assigned to McChicken, for example, will cause mcchick mcchick to be displayed. Then, press a cook cycle button beneath the word mcchick mcchick to start a cook cycle for McChicken.

Product Buttons Cook Cycle Buttons
Heat Indicator

The M3000 uses and buttons to navigate the various menus and submenus.
When programming, the left screen shows the menu or submenu item. The right screen is for data entry. Data is entered with alpha-numeric characters, scrolling through lists or by toggling between choices (see diagrams on previous page). During programming, if a button is not pushed within one minute, the computer returns to operation mode.
The 9 and 8 buttons are dual-function buttons shared with the number 1 and 2 buttons. They are located directly below the LED displays (see diagrams on previous page). Use these buttons to select or cancel functions. The 8 button is used to back out of and quit submenus.
The < FLTR and FLTR > buttons (see diagram) are used to fi lter the left and right vats of a split vat fryer on demand, while the right FLTR > button is used to fi lter a full vat on demand. If pressed once, the FLTR buttons will display the number of cook cycles remaining until a fi ltration prompt. When a FLTR button is pressed twice, the date and time of the last fi lter will be displayed.
The TEMP button, if pressed once while the fryer is on, displays current vat temperature on both sides. If the TEMP button is pressed twice while the fryer is on, it shows the setpoint temperatures of the vats. If the fryer is off, the display shows the current versions of software.
The INFO button, if pressed once when the fryer is on, shows the recovery time for each vat from the last test. Recovery displays the time required for the fryer to raise the temperature of the oil 50°F (28°C) between 250°F (121°C) and 300°F (149°C). Maximum recovery time should not exceed 1:40 for electric or 2:25 for gas.
If recovery time exceeds these times, the computer will display RECOVERY FAULT RECOVERY FAULT. The error can be cleared and alarm silenced by pressing the 9 button. The second consecutive time it will display RECOVERY FAULT CALL SERVICE RECOVERY FAULT CALL SERVICE. The error can be silenced and temporarily cleared by pressing the 9 button. However, each time the fryer is started up and the test performed, the error will continue to appear until code 0042 is entered in tech mode (see page 27).
If the INFO button is pressed and held for three seconds it shows information such as usage, fi lter statistics and last cook cycles.

Filter, Temp, Info, Programming and Navigation Buttons Cook Channel and Selection Buttons

ON/OFF ON/OFF Product Buttons
Start Two-Button Cook Cycle (Multi-Product Mode)
Press right key for full pot; press key on desired side on a split pot.
Press product key bearing icon for desired product. Press cook channel button to begin cook cycle.
Press right key for full pot; press key on desired side on a split pot.
Change From Dedicated to Multi-Product Mode
Press and hold Cook Channel button under displayed menu item for approximately 3 seconds until beep is heard. Display changes to dashed lines.
Press Temp key once. Displays show frypot temperatures.
Press Temp key twice. Displays show frypot setpoint temperatures.
Change From Multi-Product Mode to Dedicated Mode
Cancel Duty or Remove Alarm
Press product key bearing icon for desired product. Press cook channel button under display showing desired item until beep is heard (approx 3 seconds).
Press key under active display. 2
Start One-Button Cook Cycle (Dedicated Mode)
Press key under display showing desired item.


Dashed lines appear in both displays. -
Display alternates between MCCK and remaining cook time.
Press a product button.
If a duty is required for this menu item,duty is displayed when it is time to perform a duty, such as shake.
Vat with appropriate setpoint displays: MC CHICK. Skip to step 5.
Press cook channel button under duty display to cancel alarm.
If this occurs, change setpoint by pressing the button assigned to the product. When the chevrons appear, immediately press and hold the cook button until a beep is heard (approximately three seconds) and then release it.
Pull is displayed when the cook time is complete; an alarm sounds.
<<<<>>>>
Press cook channel button under pull display to cancel alarm. 11
Dashed lines reappear under active display at the end of the cook cycle.
Press a cook channel button to begin cook cycle.
McCK · McCK

Fr fries
A menu item, such as FR FRIES shows in display 1 fr fries Q7 is displayed and alternates with FRY. As the quality time counts down.
Press a cook channel button to begin the cook cycle.
Pressing the cook channel button now will launch a cook cycle and end the quality countdown. 2:34
Display alternates between abbreviated product name and remaining cook time.
QUAL is displayed when the quality time has elapsed.
Duty is displayed when itis time to shake the fry basket . duty 4
Pressing the cook channel button restores the display to FR FRIES and the unit is ready for cooking
Press cook channel button to cancel alarm.
FR FRies
1 Press cook channel button to cancel alarm.

Hash brn Hash brn
Press and quickly release product button for french fries.
Press and hold the cook channel button under the display until a beep is heard (approximately three seconds) and release.
Computer will change from Hash Brn to
; an alarm will sound.
Perform these steps on both sides to change both displays to FR FRIES.

Fr fries Fr fries
4 Computer displays FR FRIES . FR FRies
Press and hold the cook channel button under the display until a beep is heard (approximately
Press and quickly release product button for hash browns.
three seconds) and release.
Display changes to Low Temp until setpoint is reached. LOW temp fr fries
Computer display will change from FR Fries to ; an alarm sounds.
Perform these steps on both sides to change both displays to FR FRIES.
Hash · brn

The following chart maps the menu options available in the M3000 computer and indicates the location of more information on each menu item within the LOV™ Fryer Installation and Operation Manual. For more information, consult the indicated section.
Adding New Menu Items See section 4.10.2 Storing Menu Items in Product Buttons See section 4.10.3 Draining, Refi lling, and Disposing of Oil See section 4.10.4
4.11
[Press and hold ◄ FLTR or FLTR ►]
Auto Filter Maint Filter Dispose Drain to Pan Fill Vat from Drain Pan Fill Vat from Bulk (Bulk Only) Pan to Waste (Bulk Only)
4.12
[Press and hold TEMP and INFO buttons, 2 beeps, displays Level 1, enter 1234] Product Selection
4.10.2
Name Cook Time Temp Cook ID Duty Time 1 Duty Time 2 Qual Tmr AIF Disable Assign Btn
4.12.1
4.12.2
High-Limit Test 4.12.3
4.9
Level 2 Program (Manager Level)
4.13
[Press and hold TEMP and INFO buttons, 3 beeps, displays Level 2, enter 1234]
Prod Comp E-Log Password Setup
Change passwords Log of last 10 error codes Sensitivity for product
4.13.1
4.13.2
4.13.3
Setup [enter 1234] Usage [enter 4321] Level 1 [enter 1234] Level 2 [enter 1234]
Alert Tone Volume and Tone
4.13.4
Volume 1-9 Tone 1-3
Filter After Filter Time Sets amount of time between filter cycles
4.13.5
Sets number of cooks before filter prompt
4.13.6
[Press and hold ◄ and ► for 10 seconds, 3 beeps, displays TECH MODE, enter 1650] Clear Passwords Filter Pad Time
4.14
[Press and hold INFO for 3 seconds, displays Info Mode]
Filter Stats Review Usage Last Load
4.14.1
4.14.2
4.14.3

Updating the software takes approximately 20 minutes. To update the software, follow these steps:


Insert the SD card
Remove the SD card using the fi ngernail slot on the top of the card.
ing down.
with contacts fac-

Problem Probable Causes Corrective Action
A. Press the ON/OFF switch to turn
the computer on. B. This fryer may have two cords: a
computer power cord and a main power cord. If the computer cord is not plugged in, the computer will not activate. Verify computer power cord is plugged in and that circuit breaker is not tripped. C. Some fryers have a rocker power
A. Computer not turned on.
B. No power to the fryer.
C. Power switch turned off.
switch inside the cabinet below the computer. Ensure the switch is turned on. D. Ensure fuse holder is screwed in
D. Loose fuse holder.
No display on computer.
E. Computer has failed.
properly. E. Swap the computer with a computer
F. Damaged computer wiring
harness.
known to be good. If computer functions, replace the computer. F. Swap with a harness known to
G. Power supply component or
interface board has failed.
be good. If computer functions, replace the harness. G. If any component in the power
supply system (including the transformer and interface board) fail, power will not be supplied to the computer and it will not function.
Computer locks up. Computer error. Remove and restore power to the computer.
A. Wait until the previous fi ltration
cycle ends to start another fi ltration cycle. B. A computer has an error. Using
the fi lter menu, try to perform a FILL VAT FROM DRAIN FILL VAT FROM DRAIN PAN PAN on each vat (see Chapter 4 of the BIELA14 IO manual). Only computers with errors can perform this function with a fi lter busy error. Computer should clear and return to normal operation once complete. C. If fi lter busy is still displayed with
A. Another fi ltration cycle is still in
process.
filter busy filter busy.
B. Computer error.
C. Computer error.
no activity, ensure the fi lter pan is empty and remove and restore ALL power to the fryer.
M3000 display shows

Problem Probable Causes Corrective Action
Silence the alarm by pressing the 9 button. Clear the error using the code on page 25. Maximum recovery for electric is 1:40.
M3000 display shows RECOVERY FAULT RECOVERY FAULT
Recovery time exceeded maximum time limit for two or more cycles.
CALL SERVICE. CALL SERVICE.
M3000 display shows ENERGY ENERGY MISCONFIGURED MISCONFIGURED
Wrong energy type selected in setup.
Press 1234 to enter setup and set energy type for electric.
M3000 display shows EXCEPTION ERROR EXCEPTION ERROR with the description on the
An error has occurred. Press 1234 to enter setup and reconfi gure the computer.
right.
Press YES to silence alarm. The error is displayed three times. See list of issues on page 26. Fix issue. The computer displays SYSTEM SYSTEM ERROR FIXED? YES/NO. ERROR FIXED? YES/NO. Press YES. Computer displays ENTER ENTER CODE CODE. Enter 1111 to clear error code. Pressing NO will allow the fryer to cook, but error will be redisplayed every 15 minutes.
M3000 displays SERVICE SERVICE REQUIRED REQUIRED followed by
An error has occurred.
the error.
M3000 display is in wrong temperature scale
Incorrect display option programmed.
See page 28 to change temperature scale.
(Fahrenheit or Celsius).
Filter error has occurred, fi lter pad clogged, 24 hour fi lter pad change prompt has occurred, or change fi lter pad was ignored on a prior prompt.
Change the fi lter pad and ensure the fi lter pan has been removed from the fryer for a minimum of 30 seconds. Do NOT ignore CHANGE FILTER CHANGE FILTER PAD PAD prompts.
M3000 displays CHANGE CHANGE FILTER PAD FILTER PAD.
A. Pull fi lter pan out and fully reinsert
into fryer. B. Ensure the fi lter pan magnet is in
A. Filter pan is not fully inserted into
fryer. B. Missing fi lter pan magnet. C. Defective fi lter pan switch.
place and replace if missing. C. If the fi lter pan magnet is fully
INSERT pan INSERT pan.
against the switch and computer continues to display INSERT INSERT pan pan, switch is possibly defective.
This in an indication of a malfunction in the temperature control circuitry, including a failure of the high-limit thermostat.
Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).
hot-hi-1 hot-hi-1.
This is displayed only during a test of the high-limit circuit and indicates that the high-limit has opened properly.
M3000 display shows HI- HI- LIMIT LIMIT. Computer in high-limit test mode.
M3000 display shows · M3000 display shows

Problem Probable Causes Corrective Action
This display is normal when the fryer is fi rst turned on while in the melt cycle mode. To bypass the melt cycle press and hold either #1 or #2 product button under the LCD display until a chirp is heard. The computer displays EXIT EXIT MELT MELT alternating with YES YES and NO NO. Press the #1 YES button to exit melt. If the display continues, the fryer is not heating.
M3000 display shows low temp low temp alternating
Frypot temperature is between 180°F (82°C) and 315°F (157°C).
with MLT-CYCL with MLT-CYCL.
M3000 display shows ERROR RM SDCRD ERROR RM SDCRD Defective SD card. Replace card with another card.
A. This indicates a problem within the
A. Problem with the temperature
temperature measuring circuitry. Check resistance of probe, if faulty replace probe. B. Swap the computer wiring harness
measuring circuitry including the probe.
FAILURE. FAILURE.
B. Damaged computer wiring
with one known to be good. If problem is corrected, replace the harness.
harness or connector.
MAINT FILTER MAINT FILTER (Manual
Filter) won’t start. Temperature too low. Ensure fryer is at setpoint before starting MAINT FILTER. MAINT FILTER.
Remove and discard product. Press a cook button under the display with the error to remove the error. Reset the setpoint of the vat before trying to cook product.
In non-dedicated mode, a product is dropped that has a different setpoint that the current vat temperature.
M3000 display shows REMOVE DISCARD REMOVE DISCARD.
Turn off the vat with the problem. This error is displayed if the fryer loses its ability to heat oil. It is also displayed when the oil temperature is above 450°F (232°C) and the high-limit thermostat has opened, halting the heating of the oil.
M3000 display shows HEATING FAILURE HEATING FAILURE.
Failed computer, failed interface board, open high-limit thermostat.
Computer will not go into
program mode or some
Failed computer. Replace computer
buttons do not actuate.
This is displayed during a test of the high-limit circuit to indicate if the high- limit has failed.
M3000 display shows HI HI 2 BAD. 2 BAD. Computer in high-limit test mode.
Failed high-limit. This is displayed to indicate the high- limit has failed.
HELP HI-2 HELP HI-2 or HIGH HIGH LIMIT FAILURE LIMIT FAILURE.
M3000 display shows · M3000 display shows

Problem Probable Causes Corrective Action
Check that all harnesses between M3000’s, MIB, AIF and ATO are secure. Ensure 24VDC is present on pins 5 & 6 of J2 on MIB board and on J4 or J5 of AIF board. Check for loose or broken pins/wires. If the problem persists, swap out computer from one bank to another and cycle power on the fryer.
M3000 display shows software for only M3000 or MIB but not all boards.
Loose or damaged harness.
A. Ensure all cords are fully seated in
A. Three phase power cord
the receptacles, locked into place and that circuit breakers are not tripped. B. Replace computer. C. Replace computer wiring harness. D. Check high limit circuit starting at
unplugged or circuit breaker is tripped. B. Failed computer. C. Damaged computer wiring
low temp low temp, heating indicator cycles on and
off normally but fryer
harness. D. Open connection in high-limit
does not heat.
the control box connector working to the high-limit.
circuit.
A fi lter error has occurred due to dirty or clogged fi lter pad or paper, clogged fi lter pump, fi lter pump thermal overload, improperly installed fi lter pan components, worn or missing O-rings, cold oil or an actuator problem.
M3000 display shows IS IS VAT FULL? YES NO. VAT FULL? YES NO.
Follow the steps in the fl owchart on page 30.
Overwrite the fi lter after setting by re- entering the fi lter after value in level two. Ensure that the down arrow is pressed after entering the value to save the setting (see Chapter 4 in the BIELA14 IO Manual for more information).
Fryer fi lters after each
Filter after setting incorrect or software update issue.
cook cycle.
M3000 display shows

To enter any of the following codes: Press and hold and simultaneously for TEN seconds; three chirps sounds. The computer displays TECH MODE TECH MODE. Enter the codes below to perform this function.
The following codes require the removal and reinsertion of the J3 locator plug on the rear of the computer before entering the code.
The following codes are entered when prompted to do so or from an energy misconfi gured exception error.
To enter level one, level two passwords – Press and hold the TEMP and INFO buttons simultane- ously until level 1 level 1 or level 2 level 2 is displayed. Release the buttons and ENTER ENTER Code Code appears.



A SERVICE REQUIRED SERVICE REQUIRED error alternating with YES YES displays on the computer. After YES YES is pressed the alarm is silenced. The computer displays an error message from the list below three times with the location of the error. Then, the computer displays SYSTEM ERROR FIXED? SYSTEM ERROR FIXED? YES/NO YES/NO. If yes yes is chosen, enter code 1111 1111. If NO NO is chosen, the system returns to cook mode for 15 minutes then redisplays error until issue is fi xed.
Pressing the MIB reset button during any fi lter function will generate a SERVICE RE- SERVICE RE- QUIRED QUIRED error.
This is a list of the service required errors and cause.
Oil not returning to vat quickly. Possible problems: dirty pad, bad or missing O-rings, tripped or defective fi lter pump, actuators or linkage. DRAIN VALVE NOT OPEN Drain valve failed to open; the valve’s position is unknown. DRAIN VALVE NOT CLOSED Drain valve failed to close; the valve’s position is unknown. RETURN VALVE NOT OPEN Return valve failed to open; the valve’s position is unknown. RETURN VALVE NOT CLOSED Return valve failed to close; the valve’s position is unknown.
MIB BOARD Problem with CAN communications; check for loose CAN connec- tions. MIB board failure. AIF BOARD MIB detects AIF missing; AIF board failure. ATO BOARD MIB detects ATO board connection lost; ATO board failure. HIGH LIMIT FAILURE High limit circuit has an issue. AIF PROBE AIF RTD reading out of range. ATO PROBE ATO RTD reading out of range. TEMP PROBE FAILURE TEMP Probe reading out of range. MIB SOFTWARE Internal MIB software error. INVALID CODE LOCATION SD card removed during update. MISCONFIGURED ENERGY TYPE
Energy type in fryer setup is incorrect; set proper energy type gas or electric. Press 1234 to enter setup to properly confi gure fryer.
RTC INVALID DATE The date is invalid. Press 1234 to enter setup to properly confi g- ure fryer and set proper date.

A product cook is started on the right side of a split vat or in a full vat that has a different setpoint other than the current vat temperature.
E01 REMOVE DISCARD (Right)
A product cook is started on the right side of a split vat or in a full vat that has a different setpoint other than the current vat temperature.
E02 REMOVE DISCARD (Left)
E03 ERROR TEMP PROBE FAILURE TEMP Probe reading out of range.
E04 HI 2 BAD High limit reading is out of range.
E05 HOT HI 1 High limit temperature is past more than 410°F (210°C), or in CE countries, 395°F (202°C).
E06 HEATING FAILURE A component has failed in the high limit circuit such as computer, interface board, contactor or open-high limit.
E07 ERROR MIB SOFTWARE Internal MIB software error.
E08 ERROR ATO BOARD MIB detects ATO board connection lost; ATO board failure.
Oil not returning to vat quickly. Possible problems: dirty pad, bad or missing O-rings, tripped or defective fi lter pump, actuators or linkage.
E10 ERROR DRAIN VALVE NOT OPEN Drain valve failed to open; the valve’s position is unknown.
E11 ERROR DRAIN VALVE NOT CLOSED Drain valve failed to close; the valve’s position is unknown.
E12 ERROR RETURN VALVE NOT OPEN Return valve failed to open; the valve’s position is unknown.
E13 ERROR RETURN VALVE NOT CLOSED Return valve failed to close; the valve’s position is unknown.
E14 ERROR AIF BOARD MIB detects AIF missing; AIF board failure.
Cooking computer detects MIB connections lost; check software version on each computer. If versions are missing, check CAN connections between each computer; MIB board failure.
E16 ERROR AIF PROBE AIF RTD reading out of range.
E17 ERROR ATO PROBE ATO RTD reading out of range.
E19 M3000 CAN TX FULL Connection between computers lost.
E20 INVALID CODE LOCATION SD card removed during update.
E21 FILTER PAD PROCEDURE ERROR (Change Filter Pad)
25 hour timer has expired or dirty fi lter logic has activated.
E22 OIL IN PAN ERROR The MIB has detected oil may be in the pan.
E23 CLOGGED DRAIN (Gas) Vat did not empty during fi ltration.
E24 OIL RETURN (level) SENSOR FAILED (Gas)
Oil return sensor may have failed.
E25 RECOVERY FAULT Recovery time exceeded maximum time limit.
E26 RECOVERY FAULT CALL SERVICE Recovery time exceeded maximum time limit for two or more cycles.
E27 LOW TEMP ALARM Oil temperature has dropped lower than 15°F (8°C) in idle mode or 45°F (25°C) in cook mode.
E18 Not Used

Tech mode allows technicians to reset all passwords set in Levels One and Two and change the time at which the fryer calls for a fi lter pad change. The default is 25 hours.

Fryer Setup Mode is used to setup the time, date, date format, language, fryer type, vat type, oil system type, and temperature scale in the fryer’s computer. These settings are needed for the fryer to function properly and should only be changed by a technician upon initial power up after installing a new computer or after accessing from Level 1.
With the computer displaying OFF OFF:
The computer displays level 1 program level 1 program for three seconds changing to Product selection Product selection .

The computer displays ENTER CODE ENTER CODE.
The computer displays Language Language on the left and english english on the right.
The computer displays temp format temp format on the left and f on the right.
The computer displays enter time enter time on the left and current time on the right in hh:MM hh:MM format. AM AM or PM PM is displayed if 12 hour system is chosen. For example:
12 Hour Format – 7:30 AM is entered as 0730. 24 Hour Format – 2:30 is entered as 1430. Change AM AM and PM PM – use the cd buttons.

The computer displays DATE FORMAT DATE FORMAT on the left and US US on the right.
The computer displays enter date enter date on the left and MM-DD-YY MM-DD-YY or DD-MM-YY DD-MM-YY on the right changing to the current date. For example:
US Format – Dec. 5, 2008 is entered as 120508. International Format – 5 Dec. 2008 is entered as 051208.

The computer displays fryer type fryer type on the left and Elec Elec on the right.
The computer displays VAT VAT type type on the left and SPLIT SPLIT on the right.
The computer displays OIl SYSTEM OIl SYSTEM on the left and JIB JIB on the right.
The computer displays SETUP COMPLETE SETUP COMPLETE changing to off off.


If the computer displays SERVICE SERVICE REQUIRED REQUIRED, the fryer can be used in most cases by answering NO NO when the prompt for SYSTEM ERROR FIXED? YES SYSTEM ERROR FIXED? YES NO NO is displayed. The message repeats every 15 minutes until the issue is repaired and error cleared by a technician. To clear the error, enter 1111 after answering YES YES when SYSTEM ERROR FIXED? YES NO SYSTEM ERROR FIXED? YES NO is displayed.

This chart follows the process of clearing a Filter Error Filter Error prompt. The prompt is displayed when any of the following occur:

Some stores may be equipped with RTI oil storage systems. If so, some of the settings, wiring, and troubleshooting may differ from normal LOV™ fryer systems. (See next page for bulk oil wiring.) The LOV™ fryer will ONLY operate with RTI systems that have the new RTI updated three- pole fl oat switch. If the fl oat switch is the older two-pole switch, call RTI. These fl oat switches are polarity specifi c and may short to ground and damage an MIB board.
Pin 1 to Pin 2 - 24 VAC. Pin 2 to Pin 8 - 24 VAC when waste tank is full, 0 VAC when it is not full. Pin 2 to Pin 3 - 24 VAC when RTI fi ll pump is on, 0 VAC when it is off.
Troubleshooting The valves and pump should be off while MIB is resetting. If any of the valves or pumps are on dur- ing reset then the MIB board is bad or wires are shorted. If JIB valve is not opening, measure when JIB valve supposed to be open:
Voltage at MIB board from Pin 1 to Pin 2 should be 24 VAC; if not, check connections from RTI 24VAC transformer and check transformer. JIB solenoid is not opening:
Take these readings when the JIB valve is in the open position:
Reset the power; wait 60 seconds and see if the valve opens. Check voltage at ATO board on J8. Pin 9 to Pin 16 should be 24 VAC.
1. Voltage at MIB board from Pin 1 to Pin 2 should be 24 VAC; if not, check connections from RTI 24VAC transformer and check transformer at RTI. 2. Voltage at MIB board from Pin 2 to Pin 3 should be 24 VAC; if not, check MIB board is bad or wires to pump relay are shorted or both. 3. Voltage at Add pump relay should be 24 VAC; if not, check wiring from MIB board. Relay located on top of RTI system.
Waste full signal: Pin 2 to Pin 8 should be 24 VAC when full, 0 VAC when not full; if no voltage level change, then the connection from RTI switch or MIB board is bad.

BEHIND FRYER
RE D
GREEN
B LA CK
WHITE
CO NDUCTOR
GRAY 5-
CA BLE
TESTIN G BETWEEN PIN S 1 & 4 R TI
REAR OF FR YER
2 4VAC W HEN RTI TANK IS F UL L 0 VAC W H EN R TI TAN K IS EM PTY
D R OP PL UG SH OU LD READ :
1 2 3 4 5
1 2 3 4 5
BLAC K 24 VAC IN FR OM R TI (HO T)
W H ITE 24 VAC IN FRO M RTI (C OM )
G REEN 24 VAC OU T RT I PU M P
TESTIN G BETWEEN PIN S 2 & 8 J6 M IB
2 4VAC W HEN RTI TANK IS F UL L 0 VAC W H EN R TI TAN K IS NO T FUL L
M IB J6
L IN E W AST E FU LL
PUM P
LIN E ADD
C ON TRO L
SEN SE

Bulk oil systems have large oil storage tanks, typically located in the rear of the restaurant, that are connected to the rear manifold on the fryer. Waste oil is pumped from the fryer, through the fi tting located on the left, and into the disposal tanks. Fresh oil is pumped from the tanks, through the fi tting located on the right, and into the fryer (as shown below).
LOV™ fryers equipped for use with bulk oil systems have an onboard fresh oil jug. The same fi tting is used for fi lling the jug and topping off the frypot.
An orange momentary switch located adjacent to the JIB allows the operator to fi ll the JIB from the bulk oil storage tank. To fi ll the JIB, press and hold the orange button until the JIB is full then release.
Using the fi lter menu scroll to DISPOSE and select to dispose using the RTI system. When prompt- ed, open the dispose valve by pulling the handle forward. To close push the handle towards the rear of the fryer until it stops. A key lock allows the store manager to control when oil is disposed.

JIB.

RTI Wiring Connection behind plate.
The RTI JIB with fi tting.
Fittings, LOV™ Fryer.



Orange JIB reset and momentary fi ll button.
Opening the RTI dis- pose valve.
Closing the RTI dispose valve.
Fresh Oil Connection · Waste Oil Connection

Built-in Filter Box Built-in Filter Box
New Oil Pump New Oil Pump

1. Hold down “Filter” button until computer beeps twice. 2. Scroll down to “Dispose” using “Info” button then press “9” button. 3. “Dispose? Yes/No” is displayed.* 4. Press “9” to dispose of oil in pot. 5. “Draining” is displayed. 6. “Vat Empty? Yes” is displayed. 7. Press “9”. 8. “Cln Vat Complete? Yes” is displayed. 9. Press “9”. 10. “Open Dispose Valve” is displayed. Open dispose valve. 11. “Disposing” is displayed for fi ve minutes. 12. “Remove Pan” is displayed. Remove pan. 13. “Is Pan Empty? Yes No” is displayed. 14. Press “9” if fi lter pan is empty. Select “8” if pan still has oil in it. 15. “Close Dispose Valve” is displayed. Close dispose valve. 16. “Insert Pan” is displayed. Insert pan. 17. “Fill Vat From Bulk? Yes/No” is displayed. 18. Press “9”. 19. “Press and Hold Yes to Fill” alternating with “Yes” is displayed. 20. Hold down “9” to fi ll pot to desired level. 21. “Filling” is displayed while button is depressed. 22. “Continue Filling Yes/No” is displayed 23. Press “9” to continue fi lling or “8” to Exit program.
*NOTE: If the waste tank is full, the computer displays “RTI Tank Full.” Call RTI.
1. Hold down “Filter” button until computer beeps twice. 2. Scroll down to “dispose” using “Info” button and press “9” button. 3. “Dispose? Yes/No is displayed. 4. Press “9”. 5. “Draining” is displayed. 6. “Vat Empty? Yes is displayed. 7. Press “9” 8. “Cln Vat Complete? Yes” is displayed. 9. Press “9”. 10. “Open Dispose Valve” is displayed. 11. Open dispose valve by pulling completely forward to start disposal. 12. “Disposing” is displayed for four minutes. 13. “Remove Pan” is displayed. 14. Slide the fi lter pan slightly out of the fryer. 15. “Is Pan Empty? Yes/No” is displayed. 16. Press “9” if the fi lter pan is empty. Select “8” if pan still has oil in it. 17. “Close Dispose Valve” is displayed. 18. Close the dispose valve ensuring the handle is pushed completely towards the fryer. 19. “Insert Pan” is displayed. 20. “Fill Vat From Bulk? Yes/No” is displayed. 21. Press “8” if you wish to leave pot empty and exit.

1. Hold down “fi lter” button until computer beeps twice. 2. Scroll down to “Fill Vat from Bulk” using the Info button. 3. Press “9”. 4. “Fill Vat from Bulk? Yes/No” is displayed. 5. Press “9”. 6. “Press and Hold Yes to Fill / Yes” is displayed. 7. Press and hold down “9” to fi ll pot to desired level. 8. “Filling” is displayed during fi ll. 9. Release button to stop fi lling. 10. “Continue Filling? Yes/No” is displayed. 11. Press “8” to exit.
If FILTER NOW? YES/NO FILTER NOW? YES/NO, CONFIRM YES/NO CONFIRM YES/NO, or SKIM VAT SKIM VAT is displayed, the fi ll jug button is disabled until either a fi lter is complete or until no is chosen.
The system also checks these conditions. The following must be met before jug fi ll is allowed:
If using two fryer systems that are both attached to the RTI system, they may not be able to fi ll both units at the same time if they have an RTI unit with a single head. Some RTI units have dual heads which can fi ll simultaneously.


It is necessary to readdress any replaced boards by resetting all power to the entire fryer battery system.
The control power reset switch is a momentary rocker switch located behind the control box above the JIB that resets all power to all the computers and boards in the fryer. Press and hold the switch for at least 10 seconds when resetting the control power to ensure power has suffi ciently drained from boards. After releasing the momentary control power reset switch, wait at least 20 seconds until the MIB board has completely reset and all LEDs have stopped blinking before starting a function. ATO Board, LON Gateway, ATO Pump Relay, and Transformer Replacement
The LON gateway and ATO board are located inside the box behind the JIB. The LON gateway covers the ATO board and must be removed to access it. Both are connected to single phase power from the control box.
Disconnect the fryer from the electrical power supply. Locate the ATO box behind the JIB (Jug In Box). Remove the cover to expose the transformers, relay, and LON gateway (if installed; see image below, left). Mark and unplug any wires or harnesses. Once the LON gateway is removed, the ATO board is visible (see image below, right). Replace the defective component and reattach all wires or harnesses. Replace the cover. CYCLE POWER TO ENTIRE FRYER SYSTEM (see section above). Press the TEMP button on one of the M3000 computers to verify software version of the ATO. If the version is not visible, the ATO may not be connected properly.

ATO box interior, with LON gateway still installed.
ATO box interior, with LON gateway removed to expose ATO board.

The MIB controller is located inside the left cabinet (see image below). In normal operation, a cover hides the MIB controls. The LED display is visible.
1. Disconnect the fryer from the electrical power supply. 2. Remove the three torx screws from the MIB cover, exposing the MIB board (see image at right). 3. Remove the screw in the center top will allow the board to hinge down and expose the connections on the back of the board. 4. Disconnect the MIB board by carefully removing the plugs on the rear of the board (see image at right). 5. Replace with a new MIB board and reverse steps to reassemble. 6. Once replaced, reconnect the power. 7. Cycle all power to the unit to readdress the fryer using the steps on the previous page.

MIB controller cover (three screws hold it in place).
The AIF boards are located inside a protective housing underneath each frypot.
1. Disconnect the fryer from the electrical power supply. 2. Locate the AIF board to be replaced under a frypot. 3. Mark and unplug the harnesses. 4. Locate the screw on the front of the AIF assembly holding it in place. 5. Remove the screw and the front of the assembly drops down and the back tab slides out of the bracket attached to the frypot (see below). 6. Reverse steps to reassemble, ensuring that the new AIF assembly slides into the slot in the rear of the bracket. 7. Cycle all power to the unit to readdress the fryer using the steps on the previous page.



Remove this screw that secures the AIF board to the fryer.
After removing the screw, the AIF assembly drops down.
The bottom tab slides out of the bracket attached to the frypot.
2 screws Cover · 1 screw

The M3000 computer is located on the front of the fryer.
Disconnect the fryer from the electrical power supply. The controller bezel is held in place by tabs at the top and bottom. Slide the metal bezel up to disengage the lower tabs. Then slide the bezel down to disengage the upper tabs. Remove the two screws from the upper corners of the control panel. The control panel is hinged at the bottom and will swing open from the top. Unplug the wiring harnesses from the connectors on the back of the computer, marking their position for reassembly, and disconnect the grounding wires from the terminals. Re- move the computer assembly by lifting it from the hinged slots in the control panel frame.

Install the replacement computer. Reinstall the control panel assembly by reversing steps 1 thru 4. Setup the computer following the instructions on page 4-9 in the Installation and Opera- tion manual. Setup MUST be performed after replacement. Cycle all power to the unit to readdress the fryer using the steps on page 37.
Disconnect the fryer from the electrical power supply. Locate the ATO pump, behind the ATO box. Mark and unplug any wires or harnesses. Press up from the bottom on the quick disconnects to release the plumbing. The plumbing can be pulled from the pump. Loosen the four nuts attaching the pump to the pump tray. Replace the defective component and reverse above steps, and then reconnect power.

Quick disconnect. ATO pump.






Turn each computer to OFF. Press the TEMP button on each computer and verify ALL software versions are present (M3000, MIB, AIF, ATO and LON on US only). A missing version may indicate an open connection. Connections from the MIB to the AIF boards carry 24VDC on the gray cable.
2nd ATO board only in 4 and 5 batteries
The data network plugs on the boards can be swapped. (ie. J4 and J5 on the AIF board.)

Connector From/To Harness # Pin # Function Voltage Wire Color
1 24VAC Ret 24VAC Black 2 3 ATO Pump Relay 4 24VAC Ret 24VAC Black 5 6 7 JIB Reset Switch 8 JIB Low Reset 16VDC Black RTI Add Solenoid 9 24VAC 24VAC Red 10 11 ATO Pump Relay 12 24VAC 24VAC Red 13 14 15 JIB Reset Switch 16 Ground 16VDC Red
1 24VAC Ret 24VAC Orange 2 24VAC Blue 3 4 5 12VAC Ret 12VAC Red 6 12VAC Brown 7 8
J5 (Front) Transformer 8074553
1 DV - Probe Ground
White 2 DV - Probe Red 3 FV - Probe Ground White 4 FV - Probe Red
J3 - Vat #3 J2
8074655 - Vat #1 8074654 - Vat #2 8074621 - Vat #3
- Vat #2 J1
J6 Orange LED 8074555 1 16VDC 16VDC Black 2 16VDC Ret Red
2 3 Ground 4 RB7/DATA 5 RB6/CLOCK
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5VDC+ 5VDC Black 5 24VDC 24VDC Red 6 Ground White
(pins 2 & 3) or to next ATO Board
(4 & 5 vat units)
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5VDC+ 5VDC Black 5 24VDC 24VDC Red 6 Ground White

Connector From/To Harness # Pin # Function Voltage Wire Color
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5 6
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5VDC+ 5VDC Black 5 24VDC 24VDC Red 6 Ground White
1 24VAC 24VAC Black 2 24VAC Ret White
Filter Relay 3 Pump Motor 24VDC Red 4 Pump Motor Green
Blue LED 5 Blue LED + 24VDC Red 6 Blue LED - Black RTI Open Switch 7 Open Switch + Black RTI Closed Switch 8 Closed Switch + Red 9 10
J5
8074844 NON-RTI
Pan Switch 11 Pan Sw + 24VDC Black 12 Pan Sw - Red 13 14 RTI Open Switch 15 Ground - White RTI Closed Switch 16 Ground - Green
1 From RTI transformer 24VAC Black 2 Common White 3 To RTI “Add Pump” Relay 24VAC Green 4 5 6 7
J6 To RTI connection in rear of
24VAC – Full 0VAC – Not Full
8 From RTI “Waste Tank Full Sensor” Test Pins 2 to 8
Transformer · fryer 8074760 · Red

Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
On Drain valve on vat # is open.
Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Off Drain valve on vat # is closed.
Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Blink Drain valve on vat # is opening or closing or an error condition may exist.
Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
On Return valve on vat # is open.
Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Off Return valve on vat # is closed.
Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Blink Return valve on vat # is opening or closing or an error condition may exist.
Network error, displays for 10 seconds in no communications are received from the M3000 within 10 seconds after power on or MIB reset.
An “r” is displayed for ten seconds or until communication is received from the M3000 after a power on or MIB reset.
The circuit has an issue. Ensure the actuator is plugged in. Ensure the CAN connections are all securely plugged into the connectors.
E alternating with vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Indicates the AIF temperature sensor did not detect a full vat during fi ltration.
A Manual LED off The system is in auto fi ltration mode.
Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Manual LED on The system is in manual mode.
This will only be displayed in auto fi ltration mode. Filter pan is improperly seated. Any auto fi ltration messages received at this time are ignored.

Connector From/To Harness PN Pin # Function Voltage Wire Color
1 Ret + (Open) 24VDC Black 2 Ret – (Closed) 24VDC Red 3 Ret Position Purple 4 Ground White
J1 FV Return N/A
FV AIF RTD 1 Ground White 2 FV - Temp Red
DV AIF RTD 3 Ground White 4 DV - Temp Red 5 6 7 8 Oil Level Sensor
9 DV – OLS (Gas) Black 10 FV – OLS (Gas) Red
11 Locator Vat #5
Black 12 Locator Vat #4 13 Locator Vat #3 14 Locator Vat #2 15 Locator Vat #1 Locator 16 Locator Signal Black
1 Ret + (Open) 24VDC Black 2 Ret – (Closed) 24VDC Red 3 Ret Position Purple 4 Ground White
J3 DV Return N/A
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5VDC+ 5VDC Black 5 24VDC 24VDC Red 6 Ground White
8074547 AIF Board Communication and
J4 MIB J2 or AIF J5
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5VDC+ 5VDC Black 5 24VDC 24VDC Red 6 Ground White
8074547 AIF Board Communication and
J5 AIF J4 or ATO J10
1 Drain + (Open) 24VDC Black 2 Drain – (Closed) 24VDC Red 3 Drain Position Purple 4 Ground White
J6 FV Drain N/A
1 Drain + (Open) 24VDC Black 2 Drain – (Closed) 24VDC Red 3 Drain Position Purple 4 Ground White
J7 DV Drain N/A

Connector From/To Harness PN Pin # Function Voltage Wire Color
1 12VAC In 12VAC
3 12VAC In 12VAC
4 FV Heat Demand
5 V Relay 12VDC
6 DV Heat Demand
9 L/H B/L 12VDC
807-4199 SMT Computer to
11 Sound Device 5VDC
2 CAN Lo Red
Next M3000 J7 or Network
3 CAN Hi White
2 CAN Lo Red
3 CAN Hi White
J9 ONLY USED ON NON-AIF UNITS
J10


Frymaster L.L.C. 8700 Line Avenue, Shreveport, LA 71106 Service Center (800) 551-8633 or (318) 865-1711
Printed in the United States of America English © 2009 February 23, 2010
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Frypot tops off cold. | Incorrect setpoint. | Ensure setpoint is correct. | p.4 |
| No power to ATO board. | A. J5 connection unplugged. B. Fuse blown. C. Transformer malfunction. | A. Check to ensure J5 on front of ATO board is fully locked into connector. B. Ensure fuse below right control box is not blown. C. Check that proper voltage is present at transformer. See charts on pages 43-47. | p.4 |
| The yellow JIB low light won’t illuminate. | A. Loose wire connection. B. Power in the component box is not present. C. Failed transformer. | A. Ensure the yellow LED is securely attached to plug J6 on the ATO board. B. Ensure power is present in the component box. C. If power is present in component box, check the transformer for correct voltage. | p.4 |
| Frypots won’t top off. | A. Probe temperature lower than setpoint. B. Oil is too cold. C. Bad Connection. D. ATO board power loss. E. Failed transformer/harness. F. ATO pump failed. G. Failed ATO board. | A. Check to see that fryer is heating. Fryer temperature must be at setpoint. Check ATO probe resistance. If probe is bad, replace the probe. B. Ensure that the oil in the JIB is above 70°F (21°C). C. With the computer OFF, press TEMP button and ensure the ATO version appears. If not, the connection between the AIF and the ATO board may be bad. Ensure the 6-pin CAN connectors are tight between AIF (J4 and J5) and ATO (J10) boards. D. Power to the ATO board has been cut off. Restore power to the board and clear any service required errors. E. Ensure transformer in ATO box is functioning properly. Check power from transformer to ATO board. Ensure all harnesses are plugged securely into place. F. Ensure pump is operational. Check voltage to pump. Replace the pump if defective. G. Check for proper voltages using the pin position charts found on pages 43-47. If ATO found defective, replace ATO board and clear any errors. | p.5 |
| One vat tops off but other vats fail to top off. | A. Loose wire connection. B. Actuator issue. | A. Ensure all wiring harnesses are securely connected to ATO board and solenoids. B. Check return actuator to ensure actuator is functional. | p.5 |
| Incorrect vat tops off. | A. Wired incorrectly. B. Flexlines connected to wrong vat. | A. Check wiring. B. Switch fl exlines to correct vat. | p.5 |
| One vat doesn’t top off. | A. Filter error exists. B. Actuator, pump, loose connection, RTD or ATO issue. | A. Clear fi lter error properly. When change filter pad YES/ NO is displayed, do NOT press any button until the pan has been removed for at least thirty seconds. After thirty seconds have elapsed, the computer returns to OFF or last display. B. Check actuator, ATO pump, wire connections, RTD and ATO board. | p.5 |
| Auto fi ltration won’t start. | 1.Filter pan out of position. 2.Oil Level is too low. 3.Ensure MIB board is not in manual mode. 4.Ensure MIB cover is not damaged and pressing against buttons. 5.Filter relay has failed. 6.AIF disable is set to YES, blue light doesn’t light. 7.Filter motor thermal switch is tripped. 8.AIF clock enabled. | 1.Ensure fi lter pan is fully inserted into fryer. 2.Ensure oil level is above the oil level sen- sor. 3.Ensure MIB board is in “A” automatic mode. 4.Remove and replace cover and see if fi ltra- tion will start. 5.Replace fi lter relay with part number 807- 4482 24VDC relay. 6.Set AIF disable in Level 1 to NO. 7.Press fi lter motor thermal switch. 8.Ensure AIF clock is set to disabled. | p.9 |
| MIB display shows something other than an “A” or vat number. | An error has occurred and displayed character indicates error. | See MIB display diagnostics on page 46 for explanation. | p.9 |
| No power present at the MIB board | Transformer has failed in left component box. | Check output on the left transformer in left component box; should read 24VAC. If not replace transformer. | p.9 |
| MIB will not clear error. | Error remains in non-volatile memory. | Press and hold reset button in top right cor- ner for fi ve seconds. The drain, return and manual/auto LEDS will illuminate and the MIB will reset and clear any remaining errors from memory. Allow 60 seconds to reset. If an error still exists, then another issue exists. | p.9 |
| MIB indicates in- correct number of vats. | Ensure the CAN bus system is terminated at BOTH ENDS (on the M3000 connector J6 and on the ATO board connector J9) with a resistor equipped 6-pin connector. • Unplug and reseat all wiring harnesses in CAN system. Resistance between pins 2 and 3 on the CAN network connectors should be 120 ohms. • Check software version numbers on all M3000 computers and ensure all display an AIF version. If an AIF version is miss- ing, the AIF board may be missing power. Check pins 5 and on J4 and J5 of the af- fected AIF board for proper voltage. • The locator pin in J2 of the AIF board is either loose or in the incorrect position. See the chart on pages 47 of this manual for proper pin position. | p.9 | |
| MIB board alternat- ing “E” and “vat number and side.” | Network error on the CAN bus communication. | A.Ensure the CAN bus system is terminated at BOTH ENDS (on the M3000 connector J6 and on the ATO board connector J10) with a resistor equipped 6-pin connector. B.With the computer OFF, press TEMP but- ton and ensure the AIF version appears. If not, the 24V to the AIF boards may be missing. Ensure all 6-pin CAN connectors are tight between the M3000 (J6 and J7), MIB (J1 and J2), AIF (J4 and J5) and ATO (J10) boards. C.With the computer OFF, press TEMP but- ton and ensure the ATO version appears. If not, check the CAN wire harness between the AIF board J4 or J5 and the ATO board J9 or J10. The ATO fuse on the right side of the ATO box may be loose or blown; the 110V to the ATO transformer may be missing or bad. The J4/J5 connector may be loose. D.Check to see if MIB has 24V on pins 5 and 6 of J2. Check to see if 24V is present on pins 5 and 6 of wire harness plugging into J4 or J5 of the fi rst AIF board. If 24V miss- ing, check the pins. Replace the harness if necessary. E.Check continuity between each color wire on the CAN connectors into J7 on the far right computer and J10 on back of the ATO board (black to black, white to white, and red to red) and ensure there is no continu- ity between different color wires (black to red, red to white, and white to black). F.Ensure black computer locator wires are connected from ground to correct pin posi- tion (see pages 43-47). G.Ensure all boards have the corner ground wire attached and tightened. H.Check for loose locator pin or incorrect positioning in J2 of the AIF board. See the charts on pages 43-47 of this manual for proper pin position. I. Bad MIB and/or AIF board. J. Broken resistor lead. Unwrap the resistor leads and check ends. | p.10 |
| Wrong vat opens. | 1. Actuator is plugged into wrong connector. 2. Locator pin is in wrong position. | p.11 | |
| Actuator doesn’t function. | 1. No power to AIF board. 2. Actuator unplugged. 3. AIF board failure. 4. Actuator readings are out of tolerance. 5. Actuator is bad. | p.11 | |
| No display on computer. | A. Computer not turned on. B. No power to the fryer. C. Power switch turned off. D. Loose fuse holder. E. Computer has failed. F. Damaged computer wiring harness. G. Power supply component or interface board has failed. | A. Press the ON/OFF switch to turn the computer on. B. This fryer may have two cords: a computer power cord and a main power cord. If the computer cord is not plugged in, the computer will not activate. Verify computer power cord is plugged in and that circuit breaker is not tripped. C. Some fryers have a rocker power switch inside the cabinet below the computer. Ensure the switch is turned on. D. Ensure fuse holder is screwed in properly. E. Swap the computer with a computer known to be good. If computer functions, replace the computer. F. Swap with a harness known to be good. If computer functions, replace the harness. G. If any component in the power supply system (including the transformer and interface board) fail, power will not be supplied to the computer and it will not function. | p.22 |
| Computer locks up. | Computer error. | Remove and restore power to the computer. | p.22 |
| M3000 display shows filter busy. | A. Another fi ltration cycle is still in process. B. Computer error. C. Computer error. | A. Wait until the previous fi ltration cycle ends to start another fi ltration cycle. B. A computer has an error. Using the fi lter menu, try to perform a FILL VAT FROM DRAIN PAN on each vat (see Chapter 4 of the BIELA14 IO manual). Only computers with errors can perform this function with a fi lter busy error. Computer should clear and return to normal operation once complete. C. If fi lter busy is still displayed with no activity, ensure the fi lter pan is empty and remove and restore ALL power to the fryer. | p.22 |
| M3000 display shows RECOVERY FAULT CALL SERVICE. | Recovery time exceeded maximum time limit for two or more cycles. | Silence the alarm by pressing the 9 button. Clear the error using the code on page 25. Maximum recovery for electric is 1:40. | p.23 |
| M3000 display shows ENERGY MISCONFIGURED | Wrong energy type selected in setup. | Press 1234 to enter setup and set energy type for electric. | p.23 |
| M3000 display shows EXCEPTION ERROR with the description on the right. | An error has occurred. | Press 1234 to enter setup and reconfi gure the computer. | p.23 |
| M3000 displays SERVICE REQUIRED followed by the error. | An error has occurred. | Press YES to silence alarm. The error is displayed three times. See list of issues on page 26. Fix issue. The computer displays SYSTEM ERROR FIXED? YES/NO. Press YES. Computer displays ENTER CODE. Enter 1111 to clear error code. Pressing NO will allow the fryer to cook, but error will be redisplayed every 15 minutes. | p.23 |
| M3000 display is in wrong temperature scale (Fahrenheit or Celsius). | Incorrect display option programmed. | See page 28 to change temperature scale. | p.23 |
| M3000 displays CHANGE FILTER PAD. | Filter error has occurred, fi lter pad clogged, 24 hour fi lter pad change prompt has occurred, or change fi lter pad was ignored on a prior prompt. | Change the fi lter pad and ensure the fi lter pan has been removed from the fryer for a minimum of 30 seconds. Do NOT ignore CHANGE FILTER PAD prompts. | p.23 |
| M3000 display shows INSERT pan. | A. Filter pan is not fully inserted into fryer. B. Missing fi lter pan magnet. C. Defective fi lter pan switch. | A. Pull fi lter pan out and fully reinsert into fryer. B. Ensure the fi lter pan magnet is in place and replace if missing. C. If the fi lter pan magnet is fully against the switch and computer continues to display INSERT pan, switch is possibly defective. | p.23 |
| M3000 display shows hot-hi-1. | Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC). | This in an indication of a malfunction in the temperature control circuitry, including a failure of the high-limit thermostat. | p.23 |
| M3000 display shows HI- LIMIT. | Computer in high-limit test mode. | This is displayed only during a test of the high-limit circuit and indicates that the high-limit has opened properly. | p.23 |
| M3000 display shows low temp alternating with MLT-CYCL. | Frypot temperature is between 180°F (82°C) and 315°F (157°C). | This display is normal when the fryer is fi rst turned on while in the melt cycle mode. To bypass the melt cycle press and hold either #1 or #2 product button under the LCD display until a chirp is heard. The computer displays EXIT MELT alternating with YES and NO. Press the #1 YES button to exit melt. If the display continues, the fryer is not heating. | p.24 |
| M3000 display shows ERROR RM SDCRD | Defective SD card. | Replace card with another card. | p.24 |
| M3000 display shows TEMP PROBE FAILURE. | A. Problem with the temperature measuring circuitry including the probe. B. Damaged computer wiring harness or connector. | A. This indicates a problem within the temperature measuring circuitry. Check resistance of probe, if faulty replace probe. B. Swap the computer wiring harness with one known to be good. If problem is corrected, replace the harness. | p.24 |
| MAINT FILTER (Manual Filter) won’t start. | Temperature too low. | Ensure fryer is at setpoint before starting MAINT FILTER. | p.24 |
| M3000 display shows REMOVE DISCARD. | In non-dedicated mode, a product is dropped that has a different setpoint that the current vat temperature. | Remove and discard product. Press a cook button under the display with the error to remove the error. Reset the setpoint of the vat before trying to cook product. | p.24 |
| M3000 display shows HEATING FAILURE. | Failed computer, failed interface board, open high-limit thermostat. | Turn off the vat with the problem. This error is displayed if the fryer loses its ability to heat oil. It is also displayed when the oil temperature is above 450°F (232°C) and the high-limit thermostat has opened, halting the heating of the oil. | p.24 |
| Computer will not go into program mode or some buttons do not actuate. | Failed computer. | Replace computer | p.24 |
| M3000 display shows HI 2 BAD. | Computer in high-limit test mode. | This is displayed during a test of the high-limit circuit to indicate if the high- limit has failed. | p.24 |
| M3000 display shows HELP HI-2 or HIGH LIMIT FAILURE. | Failed high-limit. | This is displayed to indicate the high- limit has failed. | p.24 |
| M3000 display shows software for only M3000 or MIB but not all boards. | Loose or damaged harness. | Check that all harnesses between M3000’s, MIB, AIF and ATO are secure. Ensure 24VDC is present on pins 5 & 6 of J2 on MIB board and on J4 or J5 of AIF board. Check for loose or broken pins/wires. If the problem persists, swap out computer from one bank to another and cycle power on the fryer. | p.25 |
| M3000 display shows low temp, heating indicator cycles on and off normally but fryer does not heat. | A. Three phase power cord unplugged or circuit breaker is tripped. B. Failed computer. C. Damaged computer wiring harness. D. Open connection in high-limit circuit. | A. Ensure all cords are fully seated in the receptacles, locked into place and that circuit breakers are not tripped. B. Replace computer. C. Replace computer wiring harness. D. Check high limit circuit starting at the control box connector working to the high-limit. | p.25 |
| M3000 display shows IS VAT FULL? YES NO. | A fi lter error has occurred due to dirty or clogged fi lter pad or paper, clogged fi lter pump, fi lter pump thermal overload, improperly installed fi lter pan components, worn or missing O-rings, cold oil or an actuator problem. | Follow the steps in the fl owchart on page 30. | p.25 |
| Fryer fi lters after each cook cycle. | Filter after setting incorrect or software update issue. | Overwrite the fi lter after setting by re- entering the fi lter after value in level two. Ensure that the down arrow is pressed after entering the value to save the setting (see Chapter 4 in the BIELA14 IO Manual for more information). | p.25 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.