
FMCFEC, JCFX, KJ3FC, J3F & J65X.


Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

Please read all sections of this manual and retain for future reference.

or repairs by unqualified personnel may void the manufacturer’s warranty.
technical procedures and may not conform to onsite management operational procedures.
EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE
ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

service personnel may convert this appliance to use a gas other than that for which it was
originally configured.

anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all
from slips or contact with the hot oil.
other cooking appliance.
the fryer under a hood. Questions? Call the Frymaster Service Hotline at 1-800-551-8633.


company or gas supplier.

at the end of frying operations each day. Some food particles can spontaneously combust if left
soaking in certain shortening material. Additional information can be obtained in the filtration
manual included with the system.

the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for
cleaning.
Safe and satisfactory operation of Frymaster equipment depends upon its proper installation.
Installation MUST conform with local codes, or in the absence of local codes, to European
Community (CE) Standards.
FCC
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
A device, it has been shown to meet the Class B limits.
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the
ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B
prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.
CANCER AND/OR BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne
particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other
reproductive harm.





1.1 Functional Description Master Jet (MJ) CF Series Atmospheric gas fryers contain a welded stainless steel frypot that is directly heated by gas flames that are diffused evenly over its lower surface by ceramic targets. The flames originate from orifices in a U-shaped burner manifold positioned beneath the frypot. The orifice diameters differ for natural and propane gas as shown in the table below. For altitudes of 2000 feet and greater, contact factory for correct orifice part number.
Line Voltage ON/OFF Switch
The Pilot System (24V Circuit, Non-CE).

1.1 Functional Description (cont.) CONTROL OPTIONS MJCF Series gas fryers may be equipped with thermostat controllers or Computer Magic III.5 computers. KJ3FC variants are equipped with user-supplied or KFC-1 computers. MJCF fryers equipped with thermostat controls are turned on and off with the gas valve control knob (an On/Off switch is optional). The temperature is set by means of a knob connected directly to the frypot-mounted thermostat. MJCFE models come equipped with a rocker switch to turn the fryer on and off. Units equipped with thermostat controllers have no interface board. MJCFE Series with Melt-Cycle option: When the melt cycle switch is placed in the ON position, the fryer stays in the melt cycle mode until the switch is manually placed in the OFF position, even if the frypot is at setpoint temperature. Fryers equipped with computers have an interface board located in the component shield behind the control panel. INTERFACE BOARDS The interface board provides the link between the computer and the fryer’s components without requiring excessive wiring, and allows the computer to execute commands from one central point. Depending upon the configuration of the fryer, any of three boards may be used. Regardless of the particular board installed when the fryer was built, P/N 806-3548 is the universal replacement part (not applicable to user-supplied computers).





the MJCF Series is 4 inches long. Do not use 3-inch Fenwal thermostats in MJCF
Series fryers.

1.1 Functional Description (cont.) MJCFE Series fryers equipped with computers have a temperature probe. In these units, the probe resistance varies directly with the temperature. That is, as the temperature rises, so does resistance at a rate of approximately 2 ohms for every 1° (F or C). Circuitry in the computer monitors the probe resistance and controls burner firing when the resistance exceeds or falls below programmed temperatures (setpoints). The temperatures are programmed by means of a keypad on the face of the computer. All MJCF Series Atmospheric gas fryers are equipped with a high-limit thermostat. In the event that the fryer fails to properly control the oil temperature, the high-limit thermostat prevents the fryer from overheating to the flash point. The high-limit thermostat acts as a normally closed power switch that opens when exposed to temperatures in the range of 415°F to 435°F (213°C to 224°C). The high-limit thermostat is the same for CE and Non-CE applications. When a replacement high- limit thermostat is ordered, ensure the kit appropriate for the valve in use is ordered. 1.2 Accessing Fryers for Servicing
the draining instructions in the Operator’s manual that shipped with the fryer. 1. Shut off the gas supply to the unit. Unplug the power cord(s). Disconnect the unit from the gas supply. 2. Remove any attached restraining devices. 3. Relocate the fryer for service accessibility. 4. After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and plug in the electrical cords.


Remove plug to connect a gas pressure-measuring device to the port.




Regulator Adjustment Screw Cap 1.4 Adjusting Pilot Flame 1. On non-CE valves, remove the cap covering the pilot adjustment screw. On all valves, turn the pilot adjustment screw counterclockwise to increase the length of the flame or clockwise to decrease the length of the flame. Adjust the flame to a length of 1 to 1-½ inches (25 to 38 mm).
Pilot Adjustment Screw On Non-CE gas valves, remove this cap to access Pilot Adjustment Screw.


1.5 Cleaning Gas Valve Vent Tube 1. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease in removal.
DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. Proper spacing of the top edge of the burner ceramic targets is ¾-inch (13 mm) from the frypot side [The rear target should be adjusted to 1-inch (25 mm) from the frypot back]. To adjust target spacing, bend the brackets to which they are attached away or toward the frypot to the proper distance. (A length of board of the proper thickness is useful as a gauge to verify spacing and alignment.)

There should be about 3/4-inch spacing between the top edge of the targets and the side of the frypot, and 1-inch between the rear target and the frypot back.

1.7 Calibrating Thermostat Control 1. Fill the frypot to the lower OIL-LEVEL line with oil. If solid shortening is used, it must be tightly packed into the frypot. 2. Light the pilot. (Refer to Installation and Operation Manual that shipped with the fryer for detailed lighting instructions.) 3. Insert a good grade thermometer or pyrometer into the frypot, about one inch from the thermostat. 4. Set the thermostat to 325°F (163°C). 5. Allow the fryer to heat to 325°F (163°C) and cycle on and off three times. 6. With the oil temperature at 325°F (163°C) turn the flexible shaft slowly clockwise until the burner shuts off. (Turning the shaft counterclockwise causes the temperature to increase and the burner to light; turning it clockwise causes the temperature to decrease and shut off.) 7. Allow the fryer to sit for a few minutes and then slowly turn the flexible shaft counterclockwise until the burner lights. 8. Repeat steps 6 and 7 at least three times to ensure an accurate setting is obtained. The thermostat control is calibrated if the burner lights as the oil cools to 325°F (163°C) – not when the burner shuts off as the temperature rises. 9. Compare the reading of the pyrometer to the setting on the thermostat plate. The position of the knob on the thermostat and the reading from the pyrometer should be within 5°F (3°C) of each other. 10. If not, loosen the setscrew and stop screw securing the thermostat shaft extension to the flexible shaft. Remove the extension to expose the slot in the end of the flexible shaft. Use a flat-blade screwdriver to adjust the thermostat. 11. Once the calibration point of 325°F (163°C) is determined, allow the burner to cycle on and off at least three times to ensure it will light at the calibrated temperature. 12. Carefully replace the thermostat shaft extension, ensuring that the stop screw is pointed straight up. Tighten the stop screw and locking nut and the setscrew, being careful not to rotate the flexible shaft.
When handling the thermostat, do not rotate the shaft more than two turns in either
direction. Doing so will cause damage to the thermostat.

1.7 Calibrating Thermostat Control (cont.) 13. Close the fryer control panel and replace the screws in the upper corners. 14. Reinstall the thermostat knob with its pointer aligned with the 325°F (163°C) index mark on the temperature dial. 15. Reconnect the fryer to the electrical power supply. 1.8 Replacing Fryer Components 1.8.1 Replacing Computer
1. Disconnect the fryer from the electrical supply. 2. The controller bezel is held in place by tabs at the top and bottom. Slide the bezel up to disengage the lower tabs. Then slide the bezel down to disengage the upper tabs. 3. Remove the two screws in the upper corners of the control panel and swing the panel open from the top, allowing it to rest on its hinge tabs. 4. Disconnect the wiring harness from the back of the controller and, if replacing the harness, disconnect it from the interface board (arrows). 5. Disconnect the ground wire, and then remove the controller by lifting it from the hinge slots in the control panel frame. 6. Ensure the new computer is properly configured for the fryer on which it is installed (i.e., gas or electric, full or split pot and Celsius or Fahrenheit. Although identical in appearance, computers configured for use on one type of fryer are not directly interchangeable with those configured for use on another type. 7. Reverse the procedure to install a new controller or wiring harness.

If replacing harness, disconnect the harness from the controller and interface board (arrows).

If replacing controller, disconnect the ground wire and the 15-pin connector (arrows).

for calibration instructions.
When handling the thermostat, do not rotate the shaft more than two turns in either
direction. Doing so will cause damage to the thermostat. 1. Disconnect the fryer from the electrical supply and drain the frypot. 2. Loosen the setscrew securing the thermostat knob and remove the knob. Remove the screws from the upper left and right corners of the control panel. The control panel is hinged at the bottom and will swing open from the top. 3. Disconnect the 9-pin connector and remove the control panel from the fryer by disengaging its tabs from the hinge slots in the mounting frame. 4. Loosen the setscrews (2) securing the flexible shaft to the thermostat shaft and slip the flexible shaft off the thermostat shaft (arrow). 5. Remove the flexible shaft guide by removing the two sheet metal screws securing it to the upper frame. 6. Disconnect the thermostat leads from pin 14 in the 20-pin terminal block and from the gas valve terminal. NOTE: If the fryer is configured with a melt cycle, the thermostat leads will be connected to the melt cycle timer motor or PC board rather than to the terminal block and gas valve. Disconnect the leads from the motor or PC board if this is the case.

Remove setscrews (arrow) to remove flexible shaft from thermostat shaft.

1.8.3 Replacing Temperature Probe 1. Disconnect the fryer from the electrical supply. 2. Drain the frypot. 3. Remove the screws from the upper left and right corners of the control panel. The panel is hinged at the bottom and will swing open from the top. 4. Unplug the wiring harness from the back of the controller and disconnect the grounding wire (see Section 1.8.1, Step 4). 5. Remove the controller from the fryer by lifting it from the hinge slots in the control panel frame. 5. Remove the two screws from the base of the interface board mounting-bracket. 6. Disconnect the 12-pin plug from the back of the interface board and lay the board in the left end of the compartment with all other wires still connected. 7. Remove the 12-volt transformer from the component shield and lay it in the left end of the compartment with wires still connected. 8. Using a pin-pusher, remove the temperature probe wires (pins 1 and 2) from the 12-pin plug disconnected in step 7. 9. Unscrew the temperature probe from the frypot and remove. 10. Apply Loctite PST567 thread sealant or equivalent to new probe threads. 11. Reverse steps 1 through 10 to install the replacement probe. 1.8.4 Replacing High-Limit Thermostat – Operating Thermostat Controls 1. Disconnect the fryer from the electrical supply. 2. Drain the frypot. 3. Loosen the setscrew securing the thermostat knob and remove the knob. Remove the screws from the upper left and right corners of the control panel. The control panel is hinged at the bottom and will swing open from the top. 4. Disconnect the 9-pin connector and remove the control panel from the fryer by disengaging its tabs from the hinge slots in the mounting frame. 5. Disconnect the high-limit thermostat leads from the gas valve pilot coil.

1.8.4 Replacing High-Limit Thermostat – Operating Thermostat Controls (cont.) 6. Unscrew the high-limit thermostat from the frypot and remove. 7. Apply Loctite PST567 thread sealant or equivalent to the replacement thermostat threads. 8. Reverse steps 1 through 7 to install the replacement. 1.8.5 Replacing High-Limit Thermostat – Computer Controls 1. Disconnect the fryer from the electrical power supply. 2. Drain the frypot. 3. Remove the screws from the upper left and right corners of the computer panel. The computer is hinged at the bottom and will swing open from the top. 4. Unplug the wiring harness and disconnect the grounding wire from the controller. 5. Remove the controller from the fryer by lifting it from the hinge slots in the fryer control panel frame. 6. Remove the two screws from the base of the interface board-mounting bracket. 7. Disconnect the 12-pin plug from the back of the interface board and lay the board in the right end of the compartment with all other wires still connected. 8. Remove the 12-volt transformer and lay it in the right end of the compartment with wires still connected. 9. Remove the high-limit thermostat wires from the gas valve pilot coil and pull them up through the control shield. 10. Unscrew the high-limit thermostat from the frypot and remove. 11. Apply Loctite PST567 thread sealant or equivalent to the replacement thermostat’s threads and screw it into the frypot. 12. Attach the appropriate terminals (furnished in the replacement thermostat kit) to the thermostat leads. 13. Reverse steps 1 through 9 to complete installation of the replacement thermostat.

1.8.6 Replacing Heat Mode Indicator Light – Operating Thermostat Controls 1. Disconnect the fryer from the electrical supply. 2. Loosen the setscrew securing the thermostat knob and remove the knob. Remove the screws from the upper left and right corners of the control panel. The control panel is hinged at the bottom and will swing open from the top. 3. Disconnect the 9-pin connector and remove the control panel from the fryer by disengaging its tabs from the hinge slots in the mounting frame. 4. Carefully press the light out from the back of the control panel. Disconnect one wire at a time and reconnect it to the replacement light until all wires are transferred. 5. Carefully press the light back into the control panel. 6. Reverse steps 1-3 to reassemble the fryer. 1.8.7 Replacing Power/Melt Cycle Switch – Operating Thermostat Controls NOTE: The Power/Melt-Cycle Switch, P/N 807-1404, has been replaced with a new switch, P/N 807-3498. When ordering the new switch, order Kit 826-1792, which contains the new switch and wiring instructions. The new switch is wired differently than the old one. Ensure the new switch is wired properly before operating fryer. Consult P/N 819-5889 (MJCF, MJ45 Switch Replacement Instructions) for further detail. 1. Disconnect the fryer from the electrical supply. 2. Loosen the setscrew securing the thermostat knob and remove the knob. Remove the screws from the upper left and right corners of the control panel. The control panel is hinged at the bottom and will swing open from the top. 3. Disconnect the 9-pin connector and remove the control panel from the fryer by disengaging its tabs from the hinge slots in the mounting frame. 4. Using a flat-tipped screwdriver, disconnect the chrome bezel from the tabs on the switch and press the switch out from the front. 5. Carefully press the new switch back into the chrome bezel, ensuring the tabs on the switch engage the slots in the bezel. 6. Disconnect the wires from the old switch and reconnect to the new switch until all wires have been transferred (see note at the beginning of this procedure). 7. Reverse steps 1-3 to reassemble the fryer.

1.8.8 Replacing Melt Cycle Timer – Operating Thermostat Controls The mechanical melt cycle timer is no longer available. A solid-state timer replaces the mechanical unit. To replace the mechanical melt-cycle timer: 1. Remove all electrical power from the fryer. Unplug fryer and ensure all power switches are off. 2. Access timer by removing the control panel. Remove timer by removing two screws that hold it in place. Detach wires. 3. Attach wires to the new timer as follows:

Remove the control panel to reveal the mechanical timer (arrow). The metal plate that holds the timer- unit in place is secured with two screws. Remove the screws, lift out the timer and detach the wires.

Ground -To number 4 of clip terminals. 24VAC - To wire 28C. Melt - To wire 29C. Valve - To thermostat. 4. Bolt new timer into place. Reattach control panel.
The solid-state timer mounted on a metal plate, bolts into the space previously occupied by the mechanical timer.

DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect fryer from electrical and gas supplies. 2. On FMCF fryers, remove square-drain sections as necessary to expose burner. 3. Disconnect the wires from the gas valve terminal block, marking each wire to facilitate connections. 4. Remove the high-limit thermostat wires from the gas valve pilot coil. 5. Disconnect the pipe union collar at the left side of the gas valve (arrow).

Disconnect union (arrow) to remove burner manifold assembly.

1.8.9 Replacing Burner Ceramic Targets (cont.) 10. To replace only the ceramic targets, straighten the target locking tabs with a pair of needle nose pliers or a screwdriver, and slide the target up and off the bracket. Slide the replacement target onto the bracket and bend the locking tabs inward towards the burner target.
Remove damaged target by lifting up from bracket. Install new target and bend lock-tab in to lock target in bracket.
Straighten lock-tab to remove ceramic target.
To replace the entire target assembly, use a ½-inch (13 mm) box end wrench to remove the two brass orifices that hold the assembly to the burner manifold. Position the new assembly and replace the orifices.
brass orifices. 11. Reverse steps 1-8 to reinstall the burner assembly. Check spacing and alignment of targets in accordance with Section 1.6.

DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect fryer from electrical and gas supplies 2. Disconnect the wires from the gas valve terminal block, marking each wire to facilitate reconnections. 3. Remove the high-limit thermostat wire from the gas valve pilot coil. 4. Disconnect the pilot gas line fitting from the gas valve. 5. Disconnect the pipe union collars to the left and right of the gas valve and remove the valve. 6. Remove the pipefittings from the old gas valve and install on the replacement valve, using Loctite PST567 or equivalent pipe-thread sealant on threads. 7. Reverse steps 1-5 to install the replacement gas valve. 1.8.11 Replacing Pilot Assembly or Thermopile 1. Remove the burner assembly in accordance with steps 1-8 of Section 1.8.9.

a. Bend the clip at the bottom of the pilot assembly and press the thermopile out of the pilot assembly from the top.
b. Disconnect the thermopile fitting from
the gas valve pilot coil.
c. Reverse the above two steps to install the replacement thermopile.
Bend the clip (arrow) outward, and then press the thermopile out of the pilot assembly.

1.8.11 Replacing Pilot Assembly or Thermopile (cont.) 3. To replace the complete pilot assembly:
a. Disconnect the pilot tubing from the bottom of the pilot assembly.
b. Remove the screw from the pilot mounting-bracket to release the pilot assembly.
c. Disconnect the thermopile fitting from the gas valve pilot coil.
d. Reverse steps a through c to install the replacement pilot assembly. 4. Reinstall the burner assembly by reversing steps 1-8 of Section 1.8.9. 1.8.12 Replacing Frypot 1. Drain the frypot. 2. Remove all accessories (e.g., frypot covers, basket lift arms, etc.) from the fryer. 3. Disconnect the fryer from gas and electrical supplies. 4. Remove the screws from the top-cap above the control panel and lift it up and off the fryer(s). 5. If the fryer is equipped with other than a thermostat control, skip to Step 10. 6. Perform steps 1-6, section 1.8.2.
direction. Doing so will cause damage to the thermostat. 7. For fryers with other than thermostat controls, perform steps 1-4, section 1.8.1. 8. Disconnect the 12-pin plug from the back of the interface board. Use a pin pusher to remove the temperature probe leads (pins 1 and 2) and the high-limit thermostat leads (pins 6 and 8) from the plug. Leave all other wires connected. Leave the interface board lying on the shield. 9. Remove the louvered frame above the control panel opening. 10. Remove the screws securing the component shield to the fryer. 11. Disconnect the wires from components in component shield and mark to facilitate reconnection. 12. Disconnect the wires from the gas valve terminal block. Mark each wire to facilitate reconnection.

1.8.12 Replacing Frypot (cont.) 13. Remove the cover from the safety drain switch, disconnect the wires from the switch, and pull them out of the switch box. 14. Pull up and forward on the component shield to clear the rear mounting stud on the front of the frypot and remove it from the fryer by rotating its right side up and to the left. 15. Disconnect the pipe union on the right side of the gas valve. 16. On FMCF fryers, remove the section of square drain from the drain valve of the frypot to be removed. 17. Remove the frypot hold-down bracket. 18. Remove the screws from the flue cap sides and back, and lift it clear of the fryer(s). 19. Remove the oil return line from the front of the frypot to be removed. 20. Lift the complete frypot assembly (frypot, burner, gas valve, and flue) from the fryer cabinet. 21. Transfer the burner heat shield and burner to the replacement frypot. 22. Remove the drain valve, thermostat or temperature probe, and high-limit thermostat and install on replacement frypot.
sealant or equivalent to the threads. 23. Reverse steps 1-22 to reassemble the fryer.

1.9 Troubleshooting and Problem Isolation Because it is not feasible to attempt to include in this manual every conceivable problem or trouble condition that might be encountered, this section is intended to provide technicians with a general knowledge of the broad problem categories associated with this equipment, and the probable causes of each. With this knowledge, the technician should be able to isolate and correct any problem encountered. Problems likely encountered can be grouped into six broad categories:
6. Leakage The probable causes of each category are discussed in the following sections. Troubleshooting charts are included at the end of the chapter to assist in identifying some of the more common problems. 1.9.1 Pilot/Ignition Failures There are two categories: no pilot flame and unreliable flame. No pilot flame 1. No gas or insufficient gas supply. 2. Clogged pilot orifice. 3. Air in gas lines (usually in new installations). 4. Open or grounded high limit. Unreliable flame 1. Loose/corroded wire connections. 2. Low or no voltage out of thermopile / thermocouple (CE units). 3. Defective gas valve.

1.9.1 Pilot/Ignition Failures (cont.) Ignition failures occur when the 24VAC power supply to the gas valve is interrupted, when the gas supply is interrupted, or when the pilot flame is extinguished. There are three primary reasons for ignition failure, listed in order of probability: 1. Problems related to the gas and/or electrical power supplies. 2. Problems related to the electronic circuits. 3. Problems related to the gas valve. PROBLEMS RELATED TO THE GAS AND/OR ELECTRICAL POWER SUPPLIES The main indicators of this are that an entire battery of fryers fails to light and/or there are no indicator lights illuminated on the fryer experiencing ignition failure. Verify that the quick disconnect hose is properly connected, the fryer is plugged in, the main gas supply valve is open, and the circuit breaker for the fryer electrical supply is not tripped. PROBLEMS RELATED TO THE ELECTRONIC CIRCUITS If gas and electrical power are being supplied to the fryer, the next most likely cause of ignition failure is a problem in the 24 VAC circuit of the pilot system. If the fryer is equipped with a Filter Magic II filtration system, first verify that the drain valve is fully closed. (The valve is attached to a microswitch that must be closed for power to reach the gas valve. Often, although the valve handle appears to be in the closed position, the microswitch is still open.) If the valve is fully closed, or the fryer does not have a filtration system, refer to the troubleshooting tables in this chapter. PROBLEMS RELATED TO THE GAS VALVE If the problem is not in the 24 VAC circuit of the pilot system, it is most likely in the gas valve itself, but before replacing the gas valve refer to the troubleshooting tables in this chapter.

1.9.2 Improper Burner Functioning The burner ignites but exhibits abnormal characteristics such as "popping", incomplete lighting of the burner, fluctuating flame intensity, and flames "rolling" out of the fryer. "Popping" indicates delayed ignition. In this condition, the main gas valve is opening but the burner is not immediately lighting. When ignition does take place, the excess gas "explodes" into flame, rather than smoothly igniting. The primary causes of popping are:

1.9.2 Improper Burner Functioning (cont.) Fluctuating flame intensity is normally caused by either improper or fluctuating incoming gas pressure, but may also be the result of variations in the kitchen atmosphere. Verify incoming gas pressure in the same way as for "popping", discussed in the preceding paragraphs. Variations in the kitchen atmosphere are usually caused by air conditioning and/or ventilation unit air-exchange. As the systems start and stop, the pressure in the kitchen may change from positive or neutral to negative, or vice versa. They may also cause changes in airflow patterns that may affect flame intensity. Flames "rolling" out of the fryer are usually an indication of negative pressure in the kitchen. Air is being sucked out of the fryer enclosure and the flames are literally following the air. If negative pressure is not the cause, check for high burner manifold gas pressure in accordance with the procedures in Section 1.3. An obstructed flue, which prevents the fryer from properly exhausting, may also be the cause. An excessively noisy burner, especially with flames visible above the flue opening, may indicate that the burner gas pressure is too high, or it may simply be that the gas valve vent tube is blocked. If the gas pressure is correct and the vent tube is unobstructed, the gas valve regulator is probably defective. Occasionally a burner may apparently be operating correctly, but the fryer has a slow recovery rate. [The recovery rate is the length of time required for the fryer to increase the oil temperature from 250°F to 300°F (121°C to 149°C)]. Low burner manifold pressure and/or misaligned or missing deflector targets are usually the main causes. If both of these causes are ruled out, the probable cause is a gas valve regulator that is out of adjustment. See Section 1.3 to adjust regulator. 1.9.3 Improper Temperature Control Temperature control, including the melt cycle, is a function of several interrelated components, each of which must operate correctly. The principle component is the thermostat (in thermostat control units) or the temperature probe (in fryers equipped with computers). Depending upon the specific configuration of the fryer, other components may include the interface board and the computer. Improper temperature control problems can be categorized into melt cycle problems and failure to control at setpoint problems.

1.9.3 Improper Temperature Control (cont.) MELT CYCLE PROBLEMS NOTE: In early 1999, PC board melt cycle timers replaced melt-cycle timer motors in new fryers. See Section 1.8.8 for retrofit information. In fryers equipped with thermostat controls, the melt cycle is controlled by a mechanical timer or a PC board. Three components that that can fail are the melt-cycle timer, the melt-cycle timer microswitch or the control panel melt cycle On/Off switch. Isolate the defect and replace defective component. In fryers equipped with computers, the problem may be with the computer itself, the temperature probe, or a malfunctioning heat relay on the interface board. Refer to the troubleshooting tables in this chapter. FAILURE TO CONTROL AT SETPOINT In fryers equipped with thermostat controls, the problem will be with the thermostat itself. Possible causes are that the thermostat is out of calibration, the knob or flexible shaft is loose on the thermostat shaft, a thermostat wire is disconnected or broken, or the thermostat is defective. Refer to Section 1.7 for instructions on calibrating the thermostat. In fryers equipped with other types of controls, the problem may be with the temperature probe, the interface board, or the controller. Refer to the troubleshooting tables in this chapter. 1.9.4 Computer-Related Problems Computer Magic III.5 Features Sensitivity or "Stretch Time" Sensitivity or stretch time is a programmable feature that increases the cook time countdown based on variations in the oil temperature from the setpoint. The sensitivity for each product button has 10 settings (0 through 9). A "0" sensitivity setting will disable the feature (no change in cooking time), while a nine will provide the highest sensitivity or most change. The correct sensitivity for any product is based on the product, its density, the setpoint temperature, and the customer’s own requirements.

1.9.4 Computer-Related Problems (cont.) Recovery Time Recovery time is a method of measuring a fryer’s performance. Put simply, it is the time required for the fryer to increase the oil temperature from 250°F to 300°F (121°C to 149°C). This range is used as a standard since ambient kitchen temperatures can affect the test if lower ranges are used. The Computer Magic III.5 performs the recovery test each day as the fryer warms up. An operator can view the results of the test any time the fryer is above the 325°F (163°C) point by pressing the
button and entering the code 1652. The test results will be displayed in the computer’s LED panel in minutes and seconds. An acceptable recovery time for the MJCF Series fryers is 3 minutes, 30 seconds. Common Computer Complaints Most problems concerning computers have to do with programming them. There are four common complaints. The complaints, their causes, and corrective actions are: 1. Fryer constantly displays "
1 6 5 0, enter the correct setpoint using keypad, press
to lock in the setpoint. 2. Temperature is displayed in Celsius.
Cause: Computer is programmed to display in Celsius.
1 6 5 8. 3. Temperature is constantly displayed.
Cause: Computer is programmed for constant temperature display.
1 6 5 L. 4. Computer times down too slowly or too quickly. Cause: Computer is compensating for oil temperature via the sensitivity setting. Corrective Action: Reprogram sensitivity setting for each product in accordance with programming instructions in the Frymaster Fryer Controllers User’s Manual that shipped with the computer.
again, then press


1.9.5 Filtration Problems (cont.) Incorrectly sized or installed paper will also allow food particles and sediment to pass through and clog the suction tube on the bottom of the filter carriage. Particles large enough to block the suction tube may indicate that the crumb tray is not installed in the pan during filtering. Pan blockage can also occur if shortening is left in the pan and allowed to solidify. The heater strip on the suction tube is designed to prevent solidification of residual shortening left in the tube. It will not melt or prevent solidification of shortening in the pan. Blockage removal can be accomplished by forcing the item out with an auger or drain snake. Compressed air or other pressurized gases should not be used to force out the blockage. Possible problems with the Power Shower include clogged openings, shortening solidified in the tubes, missing clean-out plugs, and missing or worn O-rings. Cleaning the unit and replacing missing plugs and missing or worn O-rings will correct these problems. The electronics of the Filter Magic II are simple and straightforward. Microswitches, attached to the oil-return valve handles of each vat and wired in parallel, provide the 24 VAC needed to activate the pump relay coil when the handles are moved to the ON position. The activated coil pulls in the pump motor switch, supplying power to the motor. The suction tube heater and flexible hose heater are wired directly into the 24VAC source. They remain energized as long as the unit is plugged in (see diagram below).
Return Line Heater Tapes
Suction Tube (Pan) Heater Tape
Filter Magic Simplified Wiring Diagram

1.9.6 Leakage Leakage of the frypot is mostly due to improperly sealed high-limits, thermostats/temperature probes, and drain fittings. When installed or replaced, each of these components must be sealed with Loctite PST567 sealant or equivalent to prevent leakage. In very rare cases, a leak may develop along one of the welded edges of the frypot. When this occurs, the frypot must be replaced. If the sides and/or ends of the frypot are coated with oil, the most likely cause is spillage over the top of the frypot rather than leakage. The clamps, which hold the drain tube sections together, may loosen over time as the tubes expand and contract with heating and cooling during use. If the section of drain tube connected to the drain valve is removed for whatever reason, make sure that its grommet is in good condition and properly fitted around the nipple of the drain when it is reinstalled. Also, ensure that the drain tube runs downward from the drain along its whole length and has no low points where oil may accumulate. 1.9.7 Troubleshooting, Millivolt Frying Systems How the Millivolt Circuit Works The voltage output of a thermopile powers the coil of a millivolt gas valve. This output is measured in millivolts or thousandths of one volt. The high-limit thermostat acts as a safety switch. It will de-energize the gas valve when the oil in the fryer’s frypot climbs to 425°F to 450°F. An operating thermostat controls the main coil actuation and acts as the burner control.

P ilo t A d j .
H O N E Y W E L L 1/2 P S I
HONEYWELL 1/2 P.S.I.
ON
OFF
HONEYWELL
1/2 PSI
FENWALL
When troubleshooting millivolt systems, always check these areas before performing diagnostic checks on either the Robertshaw or Honeywell systems: A. Inspect all wires and component leads for damage (heat, oil, moisture, etc.). On capillary
tube-type thermostats, check for resistance on the thermostat lead wires. Wire nuts and other connectors cannot be present in a millivolt circuit as they can cause resistance. If resistance is found, solder the connectors to the wires or replace the wires.
B. Clean and verify that all wire connections and gas valve terminal connections are tight.
C. Check the length of the pilot flame (it should be about 1½-inches (38mm) long) and verify
that it contacts the top one third of the thermopile. Clean the pilot orifice and adjust the pilot strength if needed. D. Measure thermopile output with no load (i.e., with the thermopile disconnected from the gas
valve). Measurements must be made with a multimeter having a 0-1000 DC millivolt (MV) range. Light the pilot and have someone hold the gas cock knob in the depressed position. If the thermopile is a single lead (coaxial) type, measure from the lead’s end contact to its screw-in threads. If the thermopile has two leads, measure across the end terminals. The reading should be within the range of 500-800 millivolts. If not, replace the thermopile. Performing diagnostic checks on Robertshaw and Honeywell Systems are described on the following page.

ROBERTSHAW-UNITROL 7000 SYSTEM CHECK 1. Complete System Check With thermostat contacts closed and gas cock dial in the “ON” position, the main burner should ignite. Measure the reading between the 2 & 3 terminals. If the reading is more than 100MV, replace the gas valve. 2. System Resistance Check With thermostat contacts closed and main burner “ON”, measure the millivolt reading between the 1 and 3 terminals. The reading should be less than 80MV. If not, recheck the thermostat leads and connections. Replace with new or heavier gauge wires if necessary. If the reading is still greater than 80MV, replace the thermostat. 3. Automatic Pilot Dropout Check With the thermostat contacts open, hold the gas cock knob depressed with the pilot lit until the maximum millivolt output is observed between the 1 and 2 terminals. Then extinguish the pilot and observe the meter. The sound of the pilot magnet dropping should be audible. This dropout should occur between 120MV and 30MV. If it occurs outside these limits, change the gas valve.

Results 1 MV 2 & 3
HONEYWELL SYSTEM CHECK 1. Complete System Check With thermostat contacts closed and gas cock dial in the “ON” position, main burner should ignite. If not, measure across terminals 2 and 3 as indicated in the diagram. If the reading is more than 180MV, replace the gas valve. 2. System Resistance Check With thermostat contacts closed and main burner “ON”, measure the millivolt reading between terminals 1 and 3 as indicated in the diagram. The reading should be 220MV or less. If not, recheck thermostat leads and connections. Replace with new or heavier gauge wires if necessary. If the reading is still greater than 220MV, replace the thermostat. 3. Automatic Pilot Dropout Check With the thermostat contacts open, hold the gas cock knob depressed with the pilot lit until the maximum millivolt output is observed between terminals 1 and 2. Then extinguish the pilot and observe the meter. The sound of the pilot magnet dropping should be audible. This dropout should occur between 110MV and 36MV. If it occurs outside these limits, change the gas valve.

Results 1 MV 2 & 3

1.10 Troubleshooting Guides The troubleshooting guides found in the pages that follow are intended to assist service technicians in quickly isolating the probable causes of equipment malfunctions by following a logical, step-by- step process. 1.10.1 Initial Troubleshooting, Millivolt Frying Systems

cuts, kinks, etc. If the wiring is damaged, replace the affected component.
E. Thermostat out of calibration. E. Check calibration of thermostat in
accordance with procedures in Section 1.7 of this manual.
F. Thermostat or gas valve is suspect. F. Inspect and replace components if
necessary. A. One or more burner orifices clogged. A. Turn gas valve knob to OFF position.
Use a thin wire to clear obstruction from burner orifices.
B. Blocked flue outlet. B. Clear blockage from flue outlet.
C. Remove duct and allow for at least 18"
targets if required. If not required, check burner gas pressure and adjust to correct pressure if required.

PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
A. Inadequate make-up air in cooking
A. Adjust ventilation system to increase
area.
make-up air.
B. Pilot flame directed away from first
B. Reposition pilot hood to direct flame
orifice of burner.
toward first burner orifice.
C. One or more burner orifices is
C. Use a thin wire to clear obstruction
from orifices. Burner ignition is
clogged.
delayed. D. Low pilot flame [less than 1” (25mm)],
D. Adjust pilot flame height to 1–1-½"
low incoming gas pressure, or inadequate incoming gas supply line.
(25– 38.1mm), if required. If pilot flame is adequate, check incoming gas pressure and adjust to proper pressure, if required. If proper pressure cannot be achieved, check incoming-gas supply line and increase to proper size if required.
A. Clogged pilot orifice. A. Use a small wire to clear obstruction
from pilot orifice.
B. Pilot flame blowing away from pilot
B. Eliminate draft in kitchen.
generator (excessive draft in kitchen).
C. Pilot generator not inserted fully into
C. Reinsert pilot generator into pilot
pilot burner.
burner until flame surrounds tip.
D. Corroded connection where pilot
D. Clean pilot generator connection at
gas valve. Pilot won’t remain lit.
generator connects to gas valve.
E. Low pilot flame, pilot generator, high-
E. Adjust pilot flame as instructed in
limit thermostat contacts, or gas valve pilot magnet is suspect.
“Burner ignition is delayed”, if required. If pilot flame is adequate, inspect and replace pilot generator, if required. Inspect and clean high-limit contacts, if required. Replace gas valve if pilot magnet is defective.
A. Flue obstructed. A. Remove obstruction from flue. Flames rolling out of
fryer. B. Inadequate make-up air in cooking
B. Adjust ventilation system to increase
area.
make-up air.
valve. Pilot ignites, but fails to
A. Loose, dirty or corroded high-limit
A. Clean/tighten high-limit wires on gas
wires.
remain lit after gas valve knob/button is
B. Gas valve, pilot generator or high-limit
B. Inspect and replace any or all
thermostat is suspect.
defective components, if required.
released.
A. Thermostat out of calibration. A. Check calibration of thermostat in
accordance with procedures in Section 4.2 of this manual. Setpoint temperature
cannot be attained.
B. Failed thermostat. B. Replace defective thermostat as
outlined in Section 1.8.2.

PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
Burner won’t ignite. Light in ON/OFF switch
A. ON/OFF switch is off. A. Turn ON/OFF switch on.
is not illuminated.
ON/OFF switch is on, but the switch light is
A. No 24 VAC output from transformer. A. Check 24VAC circuit. Replace
transformer if defective.
not illuminated.
A. Drain microswitch circuit (filter-
A. Ensure drain valve is fully closed and
equipped units) is open.
microswitch is functioning. Replace microswitch if defective.
B. 24VAC is present at ON/OFF switch,
B. On/Off switch is defective. Replace
ON/OFF switch is on and the switch light is illuminated, but there is
but continuity of the switch in ON position is not "0".
switch with a known working switch.
no output to gas valve.
C. Continuity of thermostat is not "0"
C. Thermostat is defective. Replace with
(cooking oil/shortening temperature is at least 15°F below thermostat setting).
a known working thermostat.
D. Gas valve is suspect. D. Go to "No burner flame".
A. Pilot does not stay lit (fryer is on and
A. Check high-limit switch. Switch
thermopile output is approximately 400 millivolts.
continuity should be "0". If not, high- limit switch is defective. Replace high- limit switch.
B. Pilot does not stay lit (fryer is on and
B. Inspect thermopile (units without
thermopile output is not approximately 400 millivolts.
interface board) and replace if defective.
C. Pilot stays lit, and the high-limit and
C. Inspect gas valve and replace if
thermopile are known working, but burners fail to light.
defective.
D. Gas valve is known to be good, but
D. Inspect thermostat body (while still in
No burner flame.
there is not 24 VAC at the gas valve terminals.
frypot) for damage. Remove and replace thermostat if bent, dented or cracked. Inspect leads for fraying, burning, breaks and/or kinks. If found, remove and replace thermostat. Remove leads from terminal block, allow oil to cool 15°F below thermostat setting and check continuity. If continuity is not "0", then thermostat has failed. Replace thermostat.
E. Continuity from terminal block to gas
E. Inspect wiring for breaks or shorts and
valve thermostat wire is not "0".
repair if necessary.


not within range [Natural- 6-14" W.C. (1.49-3.49 kPa); Propane- 11-14" W.C. (2.74-3.49 kPa)]
and/or replace faulty components (defective supply shut-off valves, incorrect piping size, etc.)
B. Allow unit to cycle on and off for
approximately 30 minutes to force air from gas manifold and lines.
C. Missing or poor target alignment. C. Replace missing target(s) and/or
A. Thermostat is out of calibration. A. Calibrate thermostat. Replace
Probe Resistance Chart For use with CF Series fryers manufactured with Minco Thermistor probes only. F OHMS C F OHMS C F OHMS C F OHMS C F OHMS C 60 1059 16 130 1204 54 200 1350 93 270 1493 132 340 1634 171 65 1070 18 135 1216 57 205 1361 96 275 1503 135 345 1644 174 70 1080 21 140 1226 60 210 1371 99 280 1514 138 350 1654 177 75 1091 24 145 1237 63 215 1381 102 285 1524 141 355 1664 179 80 1101 27 150 1247 66 220 1391 104 290 1534 143 360 1674 182 85 1112 29 155 1258 68 225 1402 107 295 1544 146 365 1684 185 90 1122 32 160 1268 71 230 1412 110 300 1554 149 370 1694 188 95 1133 35 165 1278 74 235 1422 113 305 1564 152 375 1704 191 100 1143 38 170 1289 77 240 1432 116 310 1574 154 380 1714 193 105 1154 41 175 1299 79 245 1442 118 315 1584 157 385 1724 196 110 1164 43 180 1309 82 250 1453 121 320 1594 160 390 1734 199 115 1174 46 185 1320 85 255 1463 124 325 1604 163 395 1744 202 120 1185 49 190 1330 88 260 1473 127 330 1614 166 400 1754 204 125 1195 52 195 1340 91 265 1483 129 335 1624 168 405 1764 207

SAFTY DRAIN
A D J .
SWITCH (OPTIONAL)
1/2 P.S.I.
H O N E Y W E L L
HONEYWELL 1/2 P.S.I.
IN-LINE SPLICE
OFF
ON
ON/OFF SWITCH (OPTIONAL)
1/2 P.S.I.
IN-LINE SPLICE
FENWALL OPERATING THERMOSTAT
8050438C

HIGH-LIMIT THERMOSTAT
PILOT GENERATOR
(THERMOCOUPLE)
MAIN VALVE/COIL
GENERATOR (THERMOPILE)
FENWALL OPERATING THERMOSTAT 8050531A



(1) CONNECT WIRE 21C FROM PIN 1 (20 PIN TERMINAL
(2) CONNECT WIRE 22C FROM PIN 5 (20 PIN TERMINAL

PLAN WIRING DIAGRAM


REPEAT SAME CIRCUIT ON NEXT FRYER IF NEEDED
FOR 50-2 SEE INSET A-A
FILTER PUMP MOTOR
ON/OFF SWITCH
1 ST. FRYER - RIGHT OF FILTER
TO FRYER POWER SUPPLY
FOR (DIRECT) UNITS 100V 200V
120V 208V
OR 220V
230V 12C
35C NO
8050385D
M
( DIRECT ) PLAN WIRING DIAGRAM FOR FILTER MAGIC II
NO
INSET A-A
32C NO
PUMP RELAY
NO
INSET B-B
PUMP
HEATER
1 ST. FRYER - LEFT OF FILTER
FILTER PUMP MOTOR
ON/OFF SWITCH
REPEAT SAME CIRCUIT ON NEXT FRYER IF NEEDED
SEE INSET B-B
FOR 50-2



806-1698SP 1" x 36" (2.54 cm x 91.4 cm)
806-1699 1" x 48" (2.54 cm x 121.9 cm)
806-1701 ¾" x 36" (1.91 cm x 91.4 cm)
806-1700 ¾" x 48" (1.91 cm x 121.9 cm)
5 910-2662 910-4795 Connecting Strip, Tall - for separate unit
* 910-4796 Connecting Strip, Short - for battery unit
* Not illustrated. Use standard part. In Fall 2004 Frymaster introduced the Euro-Look fryer. This fryer has a rounded topcap instead of the traditional 90º angle topcap. Also round drains replaced square drains.

1 806-0225SP Deflector Assembly (Ceramic Target Assembly), Side
* 806-3605SP Deflector Assembly (Ceramic Target Assembly), Back
* 910-0226 Bracket, Deflector- Side
* 814-0034 Target, Ceramic- Side
* 910-1465 Bracket, Deflector- Back
* 810-0424 Target, Ceramic- Back
* 806-1980SP Burner Control Assembly, Natural (Metal Targets) (use 106-0010 for Single)
* 806-1981SP Burner Control Assembly, Propane (Metal Targets) (use 106-0048 for Single) 1a 230-1177 Deflector, Side Metal Target
1b 230-1180 Deflector, Rear Metal Target
2 826-1155 Ignitor Kit, Optional Piezo
3 823-0289 Manifold, Burner
4 Orifice (Altitudes 0-1999 Feet; For Alt ≥ 2000 Feet, Contact Factory)
826-1386 Natural Gas- 1.40 mm (Non-CE & CE; Qty: 10)
812-0910 Propane (LP) Gas- 0.90 mm (Non-CE Only)
812-0906 Propane (LP) Gas- 0.95 mm (CE Only)
810-0407 Manufactured Gas- 2.15 mm [Contact factory with gas specifications (I.E. CO2, CH4, N2, H2, etc.,) for correct orifice part #.]
812-0916 Manufactured Gas- 2.26 mm [Contact factory with gas specifications (I.E. CO2, CH4, N2, H2, etc.,) for correct orifice part #.] * Not illustrated. Use standard part.
807-1906 Electrode Assembly · 810-1001 Trigger


810-2071 Natural Gas, w/Thermopile (use 810-0426 for pilot only)
810-2070 Propane (LP), w/Thermopile (use 810-0427 for pilot only)
7 810-1873 Thermopile with Push-on Terminals (Used in Non-CE Pilot Assemblies)
8 812-1284 Thermocouple with Threaded Terminal- 29-½" (Used in CE Pilot Assemblies)
* 807-0699 Thermocouple with Threaded Terminal- 20" (Used in England/Germany Pilot Assemblies) 9 810-0705 Gas Line, Pilot Supply- ¼ x 23"
* 810-1700 Gas Line, Pilot Supply- ¼ x 8-¾" (Series J65X Only)
* 806-4781 Capacitor (Used on Gas Valve Terminals w/Thermostat Cont. Only)
* 810-1307 Valve, Gas Supply Turn-off (Inside Fryer Cabinet)



* Not illustrated. Use standard part.


3 900-7367SP 201-6916 Side, Left & Right - MJCF CRS Cabinet (Euro Left Side Only)
* 910-7367SP 211-8427 Side, Left & Right - MJCF S/S Cabinet (Euro Left Side Only)
* 809-0449 Screw, #10 x ½ Phip TR HD NP
* Not illustrated. Use standard part.



4 900-4428SP Brace, Upper Front & Rear, Filter Magic/Spreader Cabinet
7 106-0414SP Rail Assembly, Filter Magic (See Item #7, Section 2.3.1 for Spreader Base Assembly) 8 810-0007 Leg, Adjustable- 1-¼" Square Tubing
12 824-0253 824-1366 Fluecap, Filter Magic/Spreader Cabinet, without Foodwarmer
* 823-1453 823-4802 Fluecap, Filter Magic/Spreader Cabinet, with Foodwarmer
* 106-4109 Cabinet Assembly, Filter Magic Filter Ready Euro-Look CRS
* 106-4110 Cabinet Assembly, Filter Magic Filter Ready Euro-Look S/S
* Not illustrated. Use standard part.



4 806-5043 Leg, 6" Nickel Plated (Not Used on Filter Magic Filter Cabinet)
* 810-1205 Leg, 6" S/S (Not Used on Filter Magic Filter Cabinet)
* 806-3811 Leg Assembly, Set of 4, 6"- Nickel Plated
5 826-1095 Anchor Strap Kit (For Use on Single Fryers w/Legs)
6 826-0900 Chain Restraint Kit (For Use on Fryers w/Casters)

2.5 Component Shield, Filter Box Assemblies and Components 2.5.1 Component Shield Assemblies – No Interface Board

806-4772SP 120V, 50/60 Hz, w/o Interface Board, w/Melt Cycle Timer
806-4777SP 240V, 50/60 Hz, w/o Interface Board, w/Melt Cycle Timer

2.5.1 Component Shield Assemblies – No Interface Board (cont.)

826-1546 806-9622 Kit, Melt Cycle Timer (Replaces for Melt Cycle Timer Motor) [Items 5, 6 & 7] 5 900-8741 Bracket, Melt Cycle Timer
6 806-9613 PC Board Assembly, Melt Cycle Timer (50 and 60 Hz)
9 826-1374 Screw, #10 x ½" Hex Washer Head (Qty: 25)
* Not illustrated. Use standard part. 2.5.2 Component Shield Assemblies – With Interface Board



7 809-0349 Spacer, 4 x 6 mm, Interface Board Standoff
* Not illustrated. Use standard part. 2.5.3 Filter Box Assemblies



2 807-0012 Relay, 18 Amp- 1/3 HP 24V Coil (4-terminal)
* 807-2434 Relay, 18 Amp- 1/3 HP 24V Coil (5-terminal)
7 807-0800 Transformer, 24V – 120V 50/60 Hz 50 VA
* 807-0680 Transformer, 24V – 240V 50/60 Hz 43 VA
8 807-1999 Transformer, 24V – 240V 50/60 Hz 50 VA (CE Only)
* Not illustrated. Use standard part. 2.6 Control Panel Assemblies and Related Components


1 806-4992SP 106-4055 Frame Assembly, Control Panel * 809-0448 Clip, Tinnerman (Control Panel Screw) 2 806-0183 106-0771 Thermostat, Operating (Non-CE) * 806-9617 806-9708 Thermostat, Operating (CE Only) 3 809-0157 Screw, Set- 8-32 x 3/8" 4 810-1000 810-2954 Shaft, Flex- Thermostat Control 5 809-0050 Nut, Hex 6 826-1361 Screw, Stop (Qty: 25) 7 810-0624 810-2862 Adapter, Shaft End * 900-2071 Bracket, Shaft Guide- Thermostat Shaft * 900-2241 200-8536 Bracket, Thermostat 8 810-0334 Knob, Thermostat 9 910-7287 210-8702 Panel, Control- MJCF With Timers- Millivolt Only * 910-7280 210-8699 Panel, Control- MJCFE With Timers 10 810-0585 Timer, 15-Minute Mechanical 11 802-1473 Label, Dial- 15-Minute Mechanical Timer * 910-1551 Bezel, 15-Minute Mechanical Timer 12 810-1287 Knob, 15-Minute Timer 13 910-7288 210-8698 Panel, Control- MJCF, Millivolt Only (Older units use 910-7282) * 806-0831SP Switch, Toggle- MJCF, Millivolt Only (Older Production Units) 14 802-1470 Label, Dial Plate- Thermostat Knob 15 826-1395 Button, Plug- Thermostat Knob Shaft (Qty: 10) * 826-1338 Bushing, Heyco- Shaft Button Plug (Qty: 25) 16 910-7281 210-8701 Panel, Control- MJCFE, With Timers 17 802-0765 Label, On/Off, Light, Melt Cycle Option- MJCFE 18 807-3498 Switch, Rocker, Melt Cycle I/O, w/24V Lamp, Amber * 807-0496 Switch, Rocker Momentary on/off switch * 807-3575 Hole Plug, Switch (MJCFE Without Melt Cycle Option) 19 807-3498 Switch, On/Off (Power) * 826-1792 Switch Kit, On/Off (Power)/Melt-Cycle (To Replace Old Switches) 20 807-1525 Light, 24V (White Lens) 21 823-1800 210-6777 Panel, Control- MJCFEC (For Computers) * 210-6766 Panel, Control Euro-Look Single Non-Computer 22 910-7289 Panel, Filter- FMCF Filter Magic II Cabinet 23 807-1275 Light, Ready Indicator- 2V 24 106-1177 106-4168 Computer, CMIII.5- MJCFEC (Non-CE) * 106-1202 106-4169 Computer, CMIII.5- MJCFEC (CE) * 106-6572 Controller, Digital - MJCFE * Not illustrated. Use standard part.

2.6 Control Panel Assemblies and Related Components (cont.)

* 910-7315 Panel, Spreader Control CF Blank Panel Euro-Look
* Not illustrated. Use standard part. 2.7 Filtration System Components 2.7.1.1 Filter Magic II Drain Manifold Components


2.7.1.1 Filter Magic Drain Manifold Components (cont.)

* 826-0715SP Drain Tube Kit (Gaskets, Clamps, Connecting Hardware, Clean-Out Cover)
* 826-0716SP Sq Drain Elbow Kit (Elbow, Gaskets, Clamps, Connecting Hardware)
10 823-0714 Tube, Square Drain- 2-½ x 5.22"- FMCF Spreader Cabinet Option
12 826-1348 Cover, Drain Cleanout – FMCF (Qty: 5)
14 823-0718 Tube, Square Drain- 2-½ x 8" – FMCF
16 826-1376 Nut, Keps- 10-32 (Drain Flange Clamp – Qty: 10)
17 826-1369 Screw, 10-32 x ½" Hex Head (Qty: 10)
19 826-1345 Washer Retainer, Drain Retainer Nut (Qty: 25)
21 813-0284 Nipple, Straight With Taper- 1 x ¾" NPT BM
* Not illustrated. ** See page 2-17 for a Euro-Look parts list.

2.7.1.2 Euro-Look Drain Manifold Components

1 823-4764 Drain Tube, Left End Open /Right End Closed, Short
2 823-4763 Drain Tube, Left and Right Ends Open, Short
3 823-5031 Drain Tube, Left End Open /Right End Closed, Long
4 823-5030 Drain Tube, Left and Right Ends Open, Long
* KIT6033 Kit, Round Drain Clamp (2 or Item 7 and 1 of Item 6)
* Not illustrated. ** See page 2-16 for a standard parts list.

2.7.2 Filter Magic II Filter Pan Components – Outer Pan Components

* 806-6095SP FMCF Complete Filter Pan Assembly – Inner & Outer Pan Assembly (Crumb Screen Not Included – Order Separately, Page 2-18) 806-4470SP FMCF Filter Pan- Outer Pan Assembly, Complete
6 826-1371 Screw, #8 x ½" Hex Head (Qty: 25)
7 809-0053 Nut, 10-32 Hex (Also Used With Contactor Block Assembly)
10 809-0185 Washer, Flat- #10 SAE (Also Used With Contactor Block Assembly) 11 807-1367 Insulator, Flat Washer

2.7.2 Filter Magic II Filter Pan Components – Outer Pan Components (cont.)

16 826-1389 Bolt, ¼-20 x ¾" Hex Head (Qty: 10)
* Not illustrated. Use standard part. 2.7.3 Filter Magic Filter Pan Components – Inner Pan Components



* 806-6095SP FMCF Complete Filter Pan Assembly – Inner & Outer Pan Assembly (Crumb Screen Not Included – Order Item #8 Below) 1 823-1745SP Pan, Inner- FMCF
* 806-4866SP Pan Assembly, Inner- FMCF (Crumb Screen Not Included)
4 910-1366 Handle, Filter Pan, Back (Nearest End With Hole In Pan Bottom)
5 810-0180 Handle, Filter Pan, Front (Nearest Door On Filter Cabinet)
* 803-0171 Paper, Filter (100 Sheets) 33-¼ x 21"

2.7.4 Oil Return Handle Components – Units Built Prior To April 2001

9 826-1381 Washer, ½ I.D. x 7/8 O.D.- Nylatron (Qty: 10)
15 826-1359 Screw, 4-40 x ¾” Slotted Head (Qty: 25)
16 826-1366 Nut, Keps Hex, 4-40 (Qty: 25) Use standard part.

2.7.5 Oil Return Handle Components –Units Built April 2001 and After

9 826-1381 Washer, ½ I.D. x 7/8 O.D.- Nylatron (Qty: 10)
15 826-1359 Screw, 4-40 x ¾” Slotted Head (Qty: 25)

2.7.6 Oil Return Plumbing

2 Flexline, Oil-Return – Measure Flexline to Determine Length Needed * 810-1043 Flexline, Oil-Return- 9-½"

2.7.7 Filter Pump and Motor Components


2.7.7 Filter Pump and Motor Components (cont.)

9 809-0514 Bolt, 5/16-18 x 4-½" Grade 5 Hex Head
11 826-1264 Pump, Filter-4 GPM (Includes Items #9, #10 & #12)
18 811-0199 Conduit, 3/8" Flexible (Order By Foot- 2.4 Feet Required)
* 811-0746 Tape, Foil- 1 Roll (Required For Heater Strip Installation)

2.7.8.1 Drain Valves and Related Components


1 806-4145 Valve, Drain- 1-¼" (Includes Handle With Lock Pin) For non-filter fryers
8 826-1366 Nut, 4-40 Keps With External Teeth (Qty: 25)
* Not illustrated. ** See page 2-27 for a Euro-Look parts list.


5 809-0237 Nut, 4-40 KEPS Hex w/ Ext Tooth
7 810-1018 Valve, 1-1/4” FPD – TCF w/out Handle
** See page 2-26 for a Standard parts list.

2.7.9 Power Shower Components



* 106-2553SP Frypot, Complete (Include Combustion Chamber & Insulation)

2.8 Frypot, High-Limit and Probe Components (cont.)

5 930-6401 806-0832 Chamber, Front Combustion (Order Insulation Kit Separately)
6 900-6412 Chamber, Side Combustion (Order Insulation Kit Separately)
7 823-0290 Channel, Frypot Rear (Order Insulation Kit Separately)
9 806-0489 Flue, Front FMCF, MJCF with ¼ x12 x14½ Kaowool insulation
* 812-1256SP ECO Connector Only [Requires soldering to high-limit wires and the installation of wire nuts (14 AWG)] 14 826-1177 806-9708 Thermostat Assembly, High-Limit- 425°F
15 812-0211 Kaowool Blanket ½ x 7½ x 17½
* Not illustrated. Use standard part.


* Not illustrated.

A.1 KJ3FC & J3F Variants – Wiring Diagrams A.1.1 Computer Wiring Diagram – KJ3FC Fast-Ready
120V UNITS ONLY
GROUND
HEATING
BLK
WHT
GRN
220V, 230V, & 240V UNITS
15P
INPUT 120V AC
CONTROLS
26C 38C
TO CUSTOMER PROVIDED COMPUTER 8050402D
GROUND
21C 22C
24V 24V
OFF
ON
BLK
WHT
CONNECTION
FIELD
50/60 HZ., 1 Ø 3 WIRE SERVICE 120V, 220V, 230V, OR 240V;
VALVE
9 6 5 8 3 2 7 12
14 13 2 4 5 3 1 10
7 9 10 1 3 5 4 2 13 14
2 1 6 8 1 3 9 7 5 2
PLAN WIRING DIAGRAM
9 HI-LIMIT
PRESSURE SWITCH
PILOT GENERATOR
T'STAT
GAS VALVE
(MILLIVOLT)
OIL LEVEL SWITCH ASSY
GAS
VALVE
RELAY
12VDC
VALVE
14C 55C
NC
TROUBLE
COMPUTER CABLE
INTERFACE
BOARD
ASSEMBLY
NC
A-1

A.1.2 J3F Wiring Diagram – (Fast /Fast Computer Modified; For Reference Only)

OF SWITCH
ON
A-2

A.1.3 KFC-1 Computer Wiring Diagram – 120V
22C 21C
TO COMPUTER 8050495D
C DRAIN VALVE
MICROSWITCH
82C 51C
NC
NO
24V 12V
15 PIN CONNECTOR 9 PIN CONNECTOR
BLK
WHT
GRN
INPUT 120V AC
CONTROLS
CONTROL 16C
VALVE
9 6 5 8 3 2 7 12
14 13 2 4 5 3 1 10
11 1 3 14 13 2 5
15C 14C
120V / 24V - 60 Hz, 1 Ø 3 WIRE SERVICE
PRESSURE SWITCH
HI-LIMIT
T'STAT
PILOT GENERATOR
GAS VALVE
(MILLIVOLT)
OIL LEVEL SWITCH ASSY
VALVE
RELAY
12VDC
GAS
VALVE
INTERFACE
BOARD
A-3

A.1.4 KFC-1 Computer Wiring Diagram – 220V
22C 21C
TO KFC-1 COMPUTER 8051320A
C DRAIN VALVE
MICROSWITCH
24V 12V
82C 51C
NC
NO
15 PIN CONNECTOR 9 PIN CONNECTOR
BLK
WHT
GRN
INPUT 220V/240V AC
CONTROLS
CONTROL 16C
VALVE
9 6 5 8 3 2 7 12
14 13 2 4 5 3 1 10
11 1 3 14 13 2 5
15C 14C
220V/240V/24V - 60 Hz, 1 Ø 3 WIRE SERVICE
PRESSURE SWITCH
PILOT GENERATOR
HI-LIMIT
T'STAT
GAS VALVE
(MILLIVOLT)
OIL LEVEL SWITCH ASSY
VALVE
RELAY
12VDC
GAS
VALVE
INTERFACE
BOARD
A-4
220/240 · 220/240

A.1.5 KSCF Wiring Diagram w/ Float (CE)


A.1.6 KFC-1 Harness Diagram


A.1.7 Transformer/Filter Box Wiring for FAST Computer
A-7

A.2 Parts List – KJ3FC Variant Parts specific to KJ3FC variants are listed here. All other parts can be found in Chapter 2.


A.2 KJ3FC Variant – Parts List (cont.)

6 807-0855 Transformer- 120V/12V 50/60 Hz 20VA (KFC-1 Computers Only)
* 807-0979 Transformer- 208/240V/12V 50/60 Hz 20VA (KFC-1 Computers Only) 7 807-0067 Block, Terminal – 8-Pin
13 806-1076SP 806-5320 Switch Assembly, Pressure (Includes Items #14, 15 & 16)
16 813-0389 Tee, Hex- ¾" (7/16 x 1/8 x 7/16)
* 806-5162 106-4995 Frame, Control Panel – KFC-1 Computer
24 810-2006 Valve, Ball – 2" [Nut (Handle Retainer) Included]
* Not Illustrated Use standard part.

A.2 KJ3FC Variant – Parts List (cont.)

32 826-1366 Nut, Keps – 4-40 External Teeth (Qty: 25)
35 813-0407 Bushing, Drain Valve - 1-¼ x 2" NPT Hex









Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 FAX (Tech Support) 1-318-219-7135
1-800-551-8633 819-5186 APRIL 2005
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Burner won’t ignite. | A. Pilot is not lit. | A. Light pilot. | p.36 |
| Burner won’t ignite. | B. Loose, dirty, or corroded terminals on gas valve. | B. Clean and tighten terminals on gas valve. | p.36 |
| Burner won’t ignite. | C. Loose, dirty, or corroded terminals on thermostat. | C. Clean and tighten terminals on thermostat. | p.36 |
| Burner won’t ignite. | D. Thermostat, gas valve, or high-limit wires broken or shorted. | D. Examine wires for signs of abrasions, cuts, kinks, etc. If the wiring is damaged, replace the affected component. | p.36 |
| Burner won’t ignite. | E. Thermostat out of calibration. | E. Check calibration of thermostat in accordance with procedures in Section 1.7 of this manual. | p.36 |
| Burner won’t ignite. | F. Thermostat or gas valve is suspect. | F. Inspect and replace components if necessary. | p.36 |
| Burner partially ignites. | A. One or more burner orifices clogged. | A. Turn gas valve knob to OFF position. Use a thin wire to clear obstruction from burner orifices. | p.36 |
| Burner partially ignites. | B. Blocked flue outlet. | B. Clear blockage from flue outlet. | p.36 |
| Burner partially ignites. | C. Fryer flue connected directly to vent hood with a chimney-like duct. | C. Remove duct and allow for at least 18" (45.7cm) between flue outlet and vent hood filters. | p.36 |
| Burner partially ignites. | D. Broken or missing ceramic targets, or incorrect burner gas pressure. | D. Replace broken/missing ceramic targets if required. If not required, check burner gas pressure and adjust to correct pressure if required. | p.36 |
| Burner ignition is delayed. | A. Inadequate make-up air in cooking area. | A. Adjust ventilation system to increase make-up air. | p.37 |
| Burner ignition is delayed. | B. Pilot flame directed away from first orifice of burner. | B. Reposition pilot hood to direct flame toward first burner orifice. | p.37 |
| Burner ignition is delayed. | C. One or more burner orifices is clogged. | C. Use a thin wire to clear obstruction from orifices. | p.37 |
| Burner ignition is delayed. | D. Low pilot flame [less than 1” (25mm)], low incoming gas pressure, or inadequate incoming gas supply line. | D. Adjust pilot flame height to 1–1-½" (25– 38.1mm), if required. If pilot flame is adequate, check incoming gas pressure and adjust to proper pressure, if required. If proper pressure cannot be achieved, check incoming-gas supply line and increase to proper size if required. | p.37 |
| Pilot won’t remain lit. | A. Clogged pilot orifice. | A. Use a small wire to clear obstruction from pilot orifice. | p.37 |
| Pilot won’t remain lit. | B. Pilot flame blowing away from pilot generator (excessive draft in kitchen). | B. Eliminate draft in kitchen. | p.37 |
| Pilot won’t remain lit. | C. Pilot generator not inserted fully into pilot burner. | C. Reinsert pilot generator into pilot burner until flame surrounds tip. | p.37 |
| Pilot won’t remain lit. | D. Corroded connection where pilot generator connects to gas valve. | D. Clean pilot generator connection at gas valve. | p.37 |
| Pilot won’t remain lit. | E. Low pilot flame, pilot generator, high- limit thermostat contacts, or gas valve pilot magnet is suspect. | E. Adjust pilot flame as instructed in “Burner ignition is delayed”, if required. If pilot flame is adequate, inspect and replace pilot generator, if required. Inspect and clean high-limit contacts, if required. Replace gas valve if pilot magnet is defective. | p.37 |
| Flames rolling out of fryer. | A. Flue obstructed. | A. Remove obstruction from flue. | p.37 |
| Flames rolling out of fryer. | B. Inadequate make-up air in cooking area. | B. Adjust ventilation system to increase make-up air. | p.37 |
| Pilot ignites, but fails to remain lit after gas valve knob/button is released. | A. Loose, dirty or corroded high-limit wires. | A. Clean/tighten high-limit wires on gas valve. | p.37 |
| Pilot ignites, but fails to remain lit after gas valve knob/button is released. | B. Gas valve, pilot generator or high-limit thermostat is suspect. | B. Inspect and replace any or all defective components, if required. | p.37 |
| Setpoint temperature cannot be attained. | A. Thermostat out of calibration. | A. Check calibration of thermostat in accordance with procedures in Section 4.2 of this manual. | p.37 |
| Setpoint temperature cannot be attained. | B. Failed thermostat. | B. Replace defective thermostat as outlined in Section 1.8.2. | p.37 |
| Burner won’t ignite. Light in ON/OFF switch is not illuminated. | A. ON/OFF switch is off. | A. Turn ON/OFF switch on. | p.38 |
| ON/OFF switch is on, but the switch light is not illuminated. | A. No 24 VAC output from transformer. | A. Check 24VAC circuit. Replace transformer if defective. | p.38 |
| ON/OFF switch is on and the switch light is illuminated, but there is no output to gas valve. | A. Drain microswitch circuit (filter- equipped units) is open. | A. Ensure drain valve is fully closed and microswitch is functioning. Replace microswitch if defective. | p.38 |
| ON/OFF switch is on and the switch light is illuminated, but there is no output to gas valve. | B. 24VAC is present at ON/OFF switch, but continuity of the switch in ON position is not "0". | B. On/Off switch is defective. Replace switch with a known working switch. | p.38 |
| ON/OFF switch is on and the switch light is illuminated, but there is no output to gas valve. | C. Continuity of thermostat is not "0" (cooking oil/shortening temperature is at least 15°F below thermostat setting). | C. Thermostat is defective. Replace with a known working thermostat. | p.38 |
| ON/OFF switch is on and the switch light is illuminated, but there is no output to gas valve. | D. Gas valve is suspect. | D. Go to "No burner flame". | p.38 |
| No burner flame. | A. Pilot does not stay lit (fryer is on and thermopile output is approximately 400 millivolts. | A. Check high-limit switch. Switch continuity should be "0". If not, high- limit switch is defective. Replace high- limit switch. | p.38 |
| No burner flame. | B. Pilot does not stay lit (fryer is on and thermopile output is not approximately 400 millivolts. | B. Inspect thermopile (units without interface board) and replace if defective. | p.38 |
| No burner flame. | C. Pilot stays lit, and the high-limit and thermopile are known working, but burners fail to light. | C. Inspect gas valve and replace if defective. | p.38 |
| No burner flame. | D. Gas valve is known to be good, but there is not 24 VAC at the gas valve terminals. | D. Inspect thermostat body (while still in frypot) for damage. Remove and replace thermostat if bent, dented or cracked. Inspect leads for fraying, burning, breaks and/or kinks. If found, remove and replace thermostat. Remove leads from terminal block, allow oil to cool 15°F below thermostat setting and check continuity. If continuity is not "0", then thermostat has failed. Replace thermostat. | p.38 |
| No burner flame. | E. Continuity from terminal block to gas valve thermostat wire is not "0". | E. Inspect wiring for breaks or shorts and repair if necessary. | p.38 |
| Fluctuating or erratic lighting of burner flame. | A. Incoming gas supply pressures are not within range [Natural- 6-14" W.C. (1.49-3.49 kPa); Propane- 11-14" W.C. (2.74-3.49 kPa)] | A. Inspect gas supply to fryer. Repair and/or replace faulty components (defective supply shut-off valves, incorrect piping size, etc.) | p.39 |
| Fluctuating or erratic lighting of burner flame. | B. Air in gas supply lines (new installation). | B. Allow unit to cycle on and off for approximately 30 minutes to force air from gas manifold and lines. | p.39 |
| Fluctuating or erratic lighting of burner flame. | C. Missing or poor target alignment. | C. Replace missing target(s) and/or ensure correct target alignment. | p.39 |
| Thermostat will not adjust to correct temperature. | A. Thermostat is out of calibration. | A. Calibrate thermostat. Replace thermostat if calibration is not possible. | p.39 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.