J1C, J1X, and J2X Master Jet Series Gas Fryers Installation, Operation, Service, and Parts Manual

Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. PRINTED IN THE USA
24-Hour Service Hotline 1-800-551-8633 www.frymaster.com
service@frymaster.com

professional should perform installation, maintenance, and repairs. Installation, maintenance,
or repairs by unqualified personnel may void the manufacturer’s warranty. See Chapter 1 of
this manual for definitions of qualified personnel.
the country and/or region in which the appliance is installed. See NATIONAL CODE
REQUIREMENTS in Chapter 2 of this manual for specifics.
Manual of the U.S. Food and Drug Administration.
technical procedures and may not conform to onsite management operational procedures.
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.
service personnel may convert this appliance to use a gas other than that for which it was
originally configured.

anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all
times when the fryer is in use.
from slips or contact with the hot oil.
other appliance.
must be posted in a prominent location. This information can be obtained from the local gas
company or gas supplier.
at the end of frying operations each day. Some food particles can spontaneously combust if left
soaking in certain shortening material.
the joint between the fry vessels. Banging fry baskets on the strip to dislodge shortening will
distort the strip, adversely affecting its fit. It is designed for a tight fit and should only be
removed for cleaning.
EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE
LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH
ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.



WHAT IS COVERED This warranty covers all defects in workmanship and material in all commercial cooking appliances and computer/controller equipment manufactured by Frymaster and sold within the domestic United States, except as excluded below.
WHO IS COVERED This warranty covers only the original purchaser of Frymaster commercial cooking appliances and computer/controller equipment. This warranty is not trans ferable. You must have your original sales receipt for warranty coverage.
WHAT WE WILL DO We will repair or replace the defective appliance, component, or part. Such repair or replacement will be at the expense of Frymaster, LLC; except that travel over 100 miles or two hours, overtime, and holiday charges will be at the expense of the purchaser.
Stainless steel frypots on all fryers, except as noted below, are warranted against manufacturing defects and/or weld seam failure for the lifetime of the fryer; parts and labor, except after one year, the warranty is limited to replacement parts. Stainless frypots for models listed below are warranted for the length of time indicated.
5 Years 7 Years 10 Years GF14, GF40 H55 (Effective Pasta Systems May 1, 1998) (Gas and Electric) Gas Protector Rethermalizer Water Bath Station (Gas and Electric)
H55 and gas Protector® combustion chamber (infrared burners and structural components to mount the burners) warranted against defective material or workmanship for 7 years, parts and labor.
FENWAL THERMOSTATS Warranted for two years, parts and labor, except after one year, the warranty is limited to replacement parts.
OTHER PARTS All other parts components are warranted for one year from the date of purchase (parts and labor).
SHORTENING DISPOSAL UNIT Warranted for 90 days parts and labor. In addition, the pump is warranted for one year, parts only.
REPLACEMENT PARTS Parts, 90 days, no labor Mild steel frypot, 90 days, no labor Stainless Steel frypots, 1 year, 90 days labor Computers, 1 year, no labor
HOW TO GET SERVICE Contact our Authorized Service Agent to obtain warranty service. To find the name and location of the nearest ASA call your dealer, or call the Frymaster Service Hotline, 800-551-8633. You can also go to the Frymaster website, www.frymaster.com click on Service, click on Locator, key in zip code and it will give you the ASA for that zip code. When calling for service, please furnish the model number, serial number, series code number, voltage of your appliance, and a description of the problem. You must keep your sales receipt for proof of your date of purchase.
WHAT THIS WARRANTY DOES NOT COVER THE WARRANTIES PROVIDED BY FRYMASTER, LLC DO NOT APPLY IN THE FOLLOWING INSTANCES:
+ Damage due to misuse, abuse, alteration, or accident. + Improper or unauthorized repair. + Failure to follow installation procedures, operation instructions and/or scheduled maintenance procedures as prescribed in your Frymaster
Service and Owner’s Manual. + Damage in shipment. + Removal, alteration, or obliteration of the rating plate. + Changes in adjustment and calibrations after thirty (30) days from equipment installation date. + Failure to program computer appliances in accordance with programming procedures prescribed in your Frymaster Service and Owner’s Manual. + Equipment exported to foreign countries. + Normal maintenance items such as electric bulbs, fuses, gaskets, o-rings, interior and exterior finishes. + Travel over 100 miles or two hours, overtime or holiday charges; all of which must be paid for by the purchaser. + Consequential damages (the cost of repairing other property which is damaged), loss of time, profits, use or any other non-fryer related inciden
tal damages of any kind.
GENERAL EXCLUSIONS No warranty is provided for any Frymaster fryer used in a mobile installation or concession. Warranty protection is only offered for fryers installed in accordance with the procedures described in the Frymaster Service and Owner’s Manual. Drop-in units, such as J1X and J2X, receive parts warranty only.
There are no implied warranties of merchantability of fitness for any particular use or purpose. This warranty is the only and complete statement with respect to warranties of your commercial cooking appliances and computer/controller equipment manufactured by Frymaster. There are no other documents or oral statements for which Frymaster will be responsible.
www.frymaster.com Frymaster Domestic

CHAPTER 1: INTRODUCTION
1.1 Parts Ordering and Service Information In order to assist you as quickly as possible, the Frymaster Authorized Service Agency (ASA) or Service Department representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the fryer door. Parts orders must be placed directly with your local ASA or distributor. Included with fryers when shipped from the factory is a list of Frymaster ASAs. If you do not have access to this list, contact the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-1711. When ordering parts, the following information is required:
Model Number: Serial Number: Type of Gas or Voltage: Item Part Number: Quantity Needed: Service information may be obtained by contacting your local ASA. Information may also be obtained by calling the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865- 1711. When requesting service, please have the following information ready:
Model Number: Serial Number: Type of Gas: In addition to the model number, serial number, and type of gas, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem. 1.2 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Your fryer is equipped with a high limit thermostat, which detects high temperatures and shuts off gas to the burner assembly should the controlling thermostat fail. Additionally, J2X fryers are equipped with a safety switch built into the drain valve to prevent burner ignition while the drain valve is open. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
malfunction of your system.
DANGER DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your system and/or cause your system to malfunction. 1.3 Equipment Description J1C, J1X, and J2X Master Jet Series gas fryers are designed for all-purpose frying applications. They come equipped with thermostat controllers for controlling the temperature of cooking cycles. J1C Series gas fryers are tabletop fryers designed for limited space and all-purpose frying. J1C frypot capacity is 15-20 pounds. J1X and J2X Series gas fryers are drop-in units designed for limited space and all-purpose frying. J1X frypot capacity is 15-20 pounds. J2X frypot capacity is 30-40 pounds. The J2X is equipped with a drain safety switch. All three models are of an open-pot design and have a hand-sized opening into the deep cold zone, which makes cleaning the stainless frypot quick and easy. All fryers are shipped with a package of standard accessories. Each fryer is adjusted, tested, and inspected at the factory before crating for shipment. Frypots are constructed of welded, heavy-gauge stainless steel. Heating is supplied by a burner assembly having multiple gas jets, which are focused on metal targets located around the lower side of the frypot. The burner assembly can be configured for natural gas, propane, or manufactured gas. The frypot is drained with a manual ball valve. Master Jet Series Atmospheric fryers are equipped with a thermostat probe for precise temperature control. The probe is located on the centerline of the frypot for rapid response to changes in loads and to provide the most accurate temperature measurement. 1.4 Installation, Operating, and Service Personnel Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.6. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and or/authorized installation or service personnel, as defined in Section 1.6.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
1.5 Definitions QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.
QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, or firms, corporations, or companies, which, either in person or through a representative, are engaged in and are responsible for the installation of gas- fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qualified service personnel are those that are familiar with Frymaster equipment and who have been authorized by Frymaster, L.L.C. to perform service on Frymaster equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a prescribed minimum amount of Frymaster equipment parts. A list of Frymaster Authorized Service Agencies (ASA) was included with the fryer when it was shipped from the factory. Failure to use qualified service personnel will void the Frymaster Warranty on your equipment. 1.6 Shipping Damage Claim Procedure Your Frymaster equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the equipment for transport. What to do if your equipment arrives damaged: 1. File a claim for damages immediately, regardless of the extent of damages. 2. Inspect for and record all visible loss or damage, and ensure that this information is noted on the freight bill or express receipt and is signed by the person making the delivery. 3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be recorded and reported to the freight company or carrier immediately upon discovery. A concealed damage claim must be submitted within 15 days of the date of delivery. Ensure that the shipping container is retained for inspection.
DAMAGE OR LOSS INCURRED IN TRANSIT.

CHAPTER 2: INSTALLATION INSTRUCTIONS
2.1 General Installation Requirements Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6 of this manual, should perform all installation and service on Frymaster equipment. Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.6 of this manual. Failure to use qualified, licensed, and/or authorized installation or service personnel (as defined in Section 1.6 of this manual) to install, convert, to another gas type or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel. Where conflicts exist between instructions and information in this manual and local or national codes or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed.
open flame of any type, including those of broilers and ranges. Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Shipping Damage Claim Procedure in Chapter 1.)
fitted with legs must be lifted during movement to avoid damage to the appliance
and bodily injury. Questions? Call 1-800-551-8633. PROPER INSTALLATION IS ESSENTIAL FOR EFFICIENT, TROUBLE-FREE OPERATION OF YOUR FRYER. ANY UNAUTHORIZED ALTERATIONS MADE TO THIS EQUIPMENT WILL VOID THE FRYMASTER WARRANTY. Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Shipping Damage Claim Procedure in Chapter 1.)

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
2.1 General Installation Requirements (cont.) CLEARANCE AND VENTILATION
Hotline at 1-800-551-8633.
of unacceptable concentrations of substances harmful to the health of personnel in
the room in which it is installed.
The fryer(s) must be installed with a 6" (150 mm) clearance at both sides and back when installed adjacent to combustible construction; no clearance is required when installed adjacent to noncombustible construction. A minimum of 24" (600 mm) clearance should be provided at the front of the fryer. An important consideration of efficient fryer operation is ventilation. Ensure the fryer is installed so flue gas is removed efficiently and the kitchen ventilation system does not produce drafts that interfere with proper burner operation. The fryer flue opening must not be placed close to the intake of the exhaust fan, and the fryer must never have its flue extended in a "chimney" fashion. An extended flue changes the combustion characteristics of the fryer, causing longer recovery time. It also frequently causes delayed ignition. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear must be kept clear and unobstructed. Fryers must be installed in an area with an adequate air supply and adequate ventilation. Adequate distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank. Filters should be installed at an angle of 45 degrees. Place a drip tray beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96 states, "A minimum distance of 18 inches (450 mm) should be maintained between the flue outlet and the lower edge of the grease filter." Frymaster recommends that the minimum distance be 24 inches (600 mm) from the flue outlet to the bottom edge of the filter when the appliance consumes more than 120,000 BTU per hour. Information on construction and installation of ventilating hoods can be found in the NFPA standard cited above. A copy of the standard may be obtained from the National Fire Protection Association, Battery March Park, Quincy, MA 02269.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
2.1 General Installation Requirements (cont.) NATIONAL CODE REQUIREMENTS The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped "NAT" only to natural gas, those stamped "PRO" only to propane gas, and those stamped "MFG" only to manufactured gas. Installation shall be made with a gas connector that complies with national and local codes. Quick- Disconnect devices, if used, shall likewise comply with national and local codes. 2.2 Leg Installation
Depending upon the specific configuration ordered, the fryer might have been shipped without installed legs. If legs are installed, you may skip this section and proceed to Section 2.3, Pre- Connection Preparations. If your fryer requires the installation of legs, install them in accordance with the instructions included in your accessory package. 2.3 Pre-Connection Preparations
section.
of combustible materials at all times. After the fryer has been positioned under the fry station exhaust hood, ensure the following has been accomplished:

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
2.3 Pre-Connection Preparations (cont.)


line if the test pressure will be ½ PSIG (3.45 kPa, 13.84 inches W.C.) or greater to
avoid damage to the fryer’s gas tubes and gas valve(s).

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
The size of the gas line used for installation is very important. If the line is too small, the gas pressure at the burner manifold will be low. This may cause slow recovery and delayed ignition. The incoming gas supply line should be a minimum of ½" (13 mm) in diameter. Refer to the chart below for the minimum sizes of connection piping.


Gas Connection Pipe Sizes (Minimum incoming pipe size should be ½" (13 mm))
When using thread compound, use very small amounts on male threads only. Use a pipe thread compound that is not affected by the chemical action of LP gases (Loctite PST567 sealant is one such compound). DO NOT apply compound to the first two threads. Applying compound to the first two threads will cause clogging of the burner orifices and control valve. 2. Open the gas-supply valve to the fryer and check all piping, fittings, and gas connections for leaks. A soap and water solution should be used for this purpose.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS

used and all connections must be tested with a solution of soapy water before
Never use matches, candles, or any other ignition source to check for leaks. If gas
odors are detected, shut off the gas supply to the appliance at the main shut-off
valve and immediately contact the local gas company or an authorized service
agency for service. 3. Close the fryer drain valve and fill the frypot with water and boil-out solution to the bottom OIL- LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are described in the "Lighting Instructions" and "Boiling Out the Frypot" topics found in Chapter 3 of this manual.

unit. 4. The burner manifold pressure should be checked at this time by the local gas company or an authorized service agent. The tables below indicate the proper burner manifold pressures:

Standard Burner Manifold Gas Pressure for J1C, J1X, and J2X
Gas Pressure – J1C & J1X Pressure – J2X

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
2.5 Converting to Another Gas Type Your fryer is configured at the factory for either natural gas or Propane (LP) gas. If you desire to switch from one type of gas to another, a gas conversion kit must be installed by an Authorized Service Agency technician.

components.

Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as
(for J1C Fryers only) For fryers at elevations at or above 5,000 feet (1524 meters), call Frymaster Service (1- 800-551-8633) to determine the components appropriate for your configuration and altitude. Contact your local ASA to order the components and arrange for installation. For fryers below 5000 feet (1524 meters), see the kits listed below for conversion. Kits applicable to non-CE units only.
Natural to Propane Regulator Conversion Kit: P/N 807-1846 Pilot, regulator conversion kit, and orifices kit: P/N 826-1141 (J1C) Propane to Natural Regulator Conversion Kit: P/N 807-1849 Pilot, regulator conversion kit, and orifices kit: P/N 826-1142 (J1C)
Gas Conversion Instructions

CHAPTER 3: OPERATING INSTRUCTIONS

water or cooking oil/shortening before lighting the burners. Failure to do so will
the inherent hazards of operating a hot oil filtering system, particularly the aspects
Solid shortening must be pre-melted prior to filling frypot.

with the procedures described in this manual. Ensure that the following steps are done in sequence before lighting or re-lighting the pilot: 1. Turn off the manual shut-off valve on the incoming service line.

The pilot is mounted on the left side of the burner manifold and is accessed through an opening in the front frypot insulation. Swing the round cover open and insert a long match or taper through the hole (see photo at right) when lighting the pilot.
Insert match or taper through this hole to light pilot.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
3.1 Start-Up Procedure (cont.) LIGHTING THE PILOT 1. Ensure power to the unit is OFF, and then turn the gas valve knob to the OFF position. Wait at least 5 minutes Ensure that the thermostat is set to the required frying temperature. 2. Rotate the gas valve knob to the PILOT position (see Figure 1).
PILOT
PILOT
OFF
OFF
ON
ON
Figure 1 Figure 2 3. Push the knob in and light the pilot. (If the fryer is equipped with a piezo ignitor, repeatedly press the piezo ignitor button while depressing the gas valve knob until the pilot lights.) Continue to hold the knob in for about 60 seconds after the flame appears on the pilot. Release the knob. The pilot should remain lit.
least five minutes before attempting to re-light. 4. After the pilot remains lit, turn the knob counterclockwise to the ON position. See Figure 2. 5. The burner will now light and is controllable by the thermostat.
least 5 minutes before lighting.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
MELT CYCLE

Boiling-Out the Frypot. Complete the following steps:
1. Make sure the fryer gas valve is in the OFF or PILOT position. 2. Close the frypot drain valve. Remove the basket support rack, if required. 3. Fill the frypot to the OIL-LEVEL line. When solid shortening is used, make sure it is packed down into the frypot cold zone. 4. To melt solid shortening without scorching, alternately turn the burner ON for 3 seconds and OFF for about 10 seconds until the shortening is melted. If smoke is seen during this process, the shortening is being heated too quickly and scorching. This step is not necessary if using liquid oil.

Cycle mode until the Melt Cycle switch is placed in the OFF position.
3.2 Boiling-Out the Frypot To ensure that the frypot is free of any contamination resulting from its manufacture, shipping, and handling during installation, the frypot must be boiled out before first use. Frymaster recommends boiling out the frypot each time the oil or shortening is changed.

boils over, turn the fryer off immediately and let the solution cool for a few minutes before resuming the process. To lessen the chance of boil over, turn the fryer’s gas
1. Before lighting the burner, close the fryer drain valve(s) and fill the frypot to the bottom OIL- LEVEL line with a mixture of cold water and automatic dishwashing detergent. 2. Set the thermostat to the lowest setting. Turn the fryer on as described in Section 3.1 (Lighting the Pilot). Allow the solution to come to a boil, and then turn the gas valve knob to PILOT. Allow the solution to set for 30 minutes. Turn the gas valve knob to ON and allow the solution to come to a boil. Turn gas valve knob to PILOT and allow solution to set for 30 minutes.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
3.2 Boiling-Out the Frypot (cont.) 3. Simmer the solution for 1 hour. 4. Turn the fryer gas valve knob to the PILOT position and allow the solution to cool. 5. Add 1 gallon (3.8 liters) of cold water and stir. Drain the solution into a suitable container and clean the frypot thoroughly.
or a portable filter unit. These units are not intended for this purpose, and will be
damaged by the solution. 6. Close the drain valve and fill the frypot with clean water. Clean the frypot with a frypot cleaning brush. Rinse the frypot at least twice by filling with clean water and draining. Dry the frypot thoroughly with a clean, dry towel.
shortening is heated to cooking temperature and may cause injury to nearby
personnel.
3.3 Shutting Down the Fryer 1. Open fryer door(s) and turn gas valve knob(s) to the PILOT position. 2. Depress gas valve knob(s) and turn slightly clockwise. 3. Release and continue turning clockwise to the OFF position. 4. Place frypot covers in place if equipped.

CHAPTER 4: FILTRATION INSTRUCTIONS

the inherent hazards of operating a hot oil filtering system, particularly the aspects
of oil filtration, draining and cleaning procedures.

avoid the possibility of a serious burn caused by careless handling. The oil to be
filtered is at or near 350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position before operating any switches or valves.
Wear all appropriate safety equipment when draining and filtering cooking oil or
shortening.

Doing so will result in a flash fire if the oil or shortening splashes onto the burner.
Applying burner heat to an empty frypot will severely damage the frypot and void

appropriate container for disposal.

above the maximum fill line located on the container. The cooking oil or shortening must be drained into another suitable container. For safe, convenient draining and disposal of used cooking oil or shortening, Frymaster L.L.C. recommends the use of the Frymaster shortening disposal unit (SDU). The SDU is available through your local distributor. 1. Turn the fryer gas valve knob to PILOT. Screw the drainpipe (provided with your fryer) into the drain valve. Make sure the drainpipe is firmly screwed into the drain valve and that the opening of the curved end is pointing down.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
4. Filtration (cont.) 2. Position a metal container with a sealable cover under the drainpipe. The metal container must be able to withstand the heat of the cooking oil or shortening, and hold hot liquids. If you intend to reuse the oil or shortening, use a Frymaster filter cone holder and filter cone when a filter machine is not available. If you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container. 3. Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food particles, use the Fryer’s Friend (poker-like tool) to clear the blockage.


drain valve ball and prevent the valve from sealing securely, resulting in a leaky
valve. 4. After draining the oil or shortening, clean all food particles and residual oil or shortening from the frypot. Use caution as frypot residue can cause severe burns if it contacts bare skin. 5. Close the drain valve securely and fill the frypot with clean, filtered or fresh cooking oil or solid shortening to the bottom OIL-LEVEL line.

frypot. DO NOT operate the fryer with a block of shortening sitting in the upper portion of the frypot. Irreparable damage to the frypot and a potential flash fire will
result.

CHAPTER 5: PREVENTATIVE MAINTENANCE
5.1 Fryer Preventive Maintenance Checks and Services DAILY CHECKS AND SERVICES Inspect Fryer and Accessories for Damage Look for loose or frayed wires and cords, leaks, foreign material in frypot or inside cabinet, and any other indications that the fryer and accessories are not ready and safe for operation. Inspect the burner targets. Ensure the targets are in position above each orifice, and that the flame ignites approximately 2-½ inches (60 mm) above the orifice. The flame should strike the center of the target and be a rich blue color. Call your authorized service agency (ASA) if you see any problems. Clean Fryer Cabinet Inside and Out
can cause spattering, which can result in severe burns to nearby personnel.
length of time the cleaner remains on the food-contact surfaces. Clean inside the fryer cabinet with dry, clean cloth. Wipe all accessible metal surfaces and components to remove accumulations of oil and dust. Clean the outside of the fryer cabinet with a clean, damp cloth soaked with dishwashing detergent, removing oil, dust, and lint from the fryer cabinet. Filter Cooking Oil The cooking oil used in your fryer should be filtered at least once every day (more often if the fryer is in constant use). Refer to Chapter 4, Filtration Instructions, for details.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
5.1 Fryer Preventive Maintenance Checks and Services (cont.) QUARTERLY CHECKS AND SERVICES Drain and Clean Frypot During normal usage of your fryer, a deposit of carbonized cooking oil will gradually form on the inside of the frypot. This deposit must be periodically removed to maintain your fryer’s efficiency.
for disposal. For safe, convenient draining and disposal of used cooking oil, Frymaster recommends the use of our shortening disposal unit (SDU). The SDU is available through your local distributor. Clean Detachable Parts and Accessories As with the frypot, a deposit of carbonized oil will accumulate on detachable parts and accessories such as baskets. Wipe all detachable parts and accessories with a clean cloth dampened with a detergent solution. Rinse and thoroughly dry each part. Check Calibration of Thermostat Temperature Control Knob 1. Ensure frypot is filled with cooking oil. 2. Set the temperature control knob to frying temperature. 3. Let the burner cycle on and off automatically three times in order for the cooking oil temperature to become uniform. If necessary, stir to get all shortening in the bottom of the frypot melted. 4. Insert a good-grade thermometer or pyrometer into the oil, with the end touching the fryer temperature probe. 5. When the burner starts for the fourth time, the thermometer/pyrometer reading should be within ± 5ºF (2ºC) of the temperature knob setting. If not, calibrate as follows:
a. Loosen the setscrew in the temperature control knob until the knob rotates freely on the shaft. b. Rotate the knob until the index line on the knob is aligned with the marking that corresponds
to the thermometer or pyrometer reading.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
5.1 Fryer Preventive Maintenance Checks and Services (cont.) c. Hold the knob and tighten the setscrew.
d. Recheck the thermometer/pyrometer reading against the temperature control knob setting the
next time the burner comes on.
e. Repeat steps 4.a. through 4.d. until the thermometer/pyrometer reading and knob setting are
within ± 5ºF (2°C). If calibration is not possible, contact an authorized service agency (ASA) for service.
Clean Gas Valve Vent Tube 1. Carefully unscrew the vent tube from the valve. (NOTE: The vent tube may be straightened by hand.) 2. Pass a piece wire through the tube to remove any obstruction. 3. Remove the wire and blow through the tube to ensure it is clear. 4. Reinstall tube and bend it so that the opening is pointing downward. SEMI-ANNUAL CHECKS AND SERVICES
Check Burner Manifold Pressure
arrange this service.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING
6.1 Introduction This chapter provides an easy reference guide to the more common problems that may occur during the operation of your equipment. If you are in doubt as to the proper action to take, do not hesitate to call the Frymaster Technical Service Department or your local Frymaster authorized service agency (ASA) for assistance.
appliance when filled hot cooking oil/shortening or to transfer hot cooking
PROBLEM Probable Causes Corrective Action
A. Thermostat wires damaged or
A. Repair or replace thermostat
broken. B. Thermostat set too low. C. Thermostat out of calibration. D. Thermostat contacts burned and
wires. B. Increase thermostat setting. C. Recalibrate the thermostat. D. Replace the thermostat.
call for heat (does
not energize gas control valve at all).
pitted.
A. Thermostat out of calibration. B. Thermostat contacts
A. Recalibrate the thermostat. B. Replace the thermostat.
control at set point.
contaminated.
A. Light pilot per instructions in
A. Pilot is not lit.
Chapter 3 of this manual. B. Verify that unit is correctly
B. Drain valve is not fully closed.
plugged in and that circuit breaker is not tripped. C. Verify that the gas line
(J2X) C. No gas being supplied to unit.
light.
connections are properly connected, that any cutoff valves between the fryer and the gas main are open, and that the main gas cutoff valve is open.
Thermostat does not · Thermostat does not · Burner does not

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
6.3 Troubleshooting Abnormal Burner Operation
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
A. Loose, dirty, or corroded
A. Clean and tighten terminals on gas
terminals on gas valve. B. High resistance in contacts of
valve and thermostat. B. Replace thermostat. C. Calibrate thermostat. D. Replace gas valve. E. Turn gas valve knob to ON
thermostat. C. Thermostat out of calibration. D. Automatic gas valve defective. E. Automatic gas valve knob turned
Main burner will not
come on. Pilot
remains lit.
position.
to PILOT position.
A. Install new rear burner flame
deflector. B. Adjust gas pressure.
A. Rear burner flame deflector
broken off. B. Burner gas pressure too high or
J1C & J1X: Natural Gas – 4 in. W.C. (1.0 kPa). LP Gas – 10.0 in. W.C. (2.50 kPa). J2X: Natural Gas – 3 in. W.C. (.75 kPa). LP Gas – 8.25 in. W.C. (2.0 kPa). C. Clean burner orifices and blow
too low. C. One or more main burner orifices
Main burner does not light all the way
around.
clogged. D. Fryer flue connected directly to
out with compressed air. D. Remove chimney-like duct and
vent hood with a chimney-like duct.
allow for at least 18" (46 cm) between flue outlet and vent hood filters.
Fryer is operating normally, but flames
Shut the fryer down and clean the gas valve vent tube in accordance with the instructions on Page 5-3 of this manual.
Obstructed gas valve vent tube.
are rolling out of the
front of the burner.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
A. Flue obstructed. B. Too little make-up air in store.
A. Clean obstruction from flue. B. Increase make-up air into store.
Flame rolling out from under fryer.
A. Install new burner flame
A. One or more burner flame
deflectors. B. Adjust pilot flame to 1 ½ inches
deflectors broken off. B. Pilot flame low – less than 1 inch
(38 mm). C. Reposition pilot hood to direct
(25.4 mm). C. Pilot flame directed away from
Main burner delayed ignition (when delay is only 2
flame toward first burner orifice. D. Have local gas company raise
first orifice on main burner. D. Fryer incoming gas pressure too
or 3 seconds).
incoming gas to the proper pressure. E. Replace incoming gas line with
low. E. Fryer incoming gas line too small. F. One or more burner orifices
proper size. F. Clean burner orifices with proper
clogged.
orifice drill.
A. Gas valve pilot magnet weak. B. Pilot generator has low millivolt
A. Replace gas valve. B. Replace pilot generator. C. Replace high-limit. D. Clean/tighten high-limit wires on
Pilot light remains lit when gas valve is
output. C. High-limit thermostat stuck open. D. Loose, dirty, or corroded high-
pushed in, but goes
out when released.
the gas valve.
limit wires.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
A. Automatic gas valve knob turned
to off position. B. Low pilot flame. C. Clogged pilot orifice. D. Pilot burner clogged around pilot
A. Turn gas valve to PILOT position,
relight pilot. B. Adjust pilot flame to 1 ½ inches
(38mm). C. Remove and clean the pilot
generator. E. Pilot flame blowing away from
orifice. Reinstall. D. Remove pilot burner. Clean
pilot generator (excessive draft in kitchen). F. Pilot generator not inserted fully
burner. E. Eliminate draft in the kitchen. F. Reinsert pilot generator into pilot
Pilot outage.
into pilot burner. G. Pilot generator low output. H. High resistance in high-limit
burner until flame surrounds tip. G. Replace pilot generator. H. Replace high-limit thermostat. I. Replace gas valve. J. Clean pilot generator connection
thermostat contacts. I. Defective pilot magnet in gas
valve. J. Corroded connection where pilot
at gas valve.
generator connects to gas valve.

CHAPTER 7: SERVICE PROCEDURES

4 Item Description Reference 1 Screw in Dial Plate 7.1, Step 2 2 Thermostat Wires 7.1, Step 4 3 Pilot Generator Wires 7.3, Step 1 4 Pressure Tap Plug 7.5, Step 2 5 Pilot Gas Line and Fitting 7.6, Step 3 6 Pipe Union 7.7, Step 4 7 Three Screws Attaching Cowl/Topcap 7.10, Step 4

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
1. Fill the frypot to the OIL-LEVEL LINE with shortening. Pre-melt solid shortening before starting calibration. 2. Ensure the gas valve knob is in the OFF position. 3. Insert a mercury thermometer or pyrometer in the center of the frypot 2 to 3 inches (50 to 75mm) deep. 4. Turn the fryer gas valve to the ON position. 5. When the shortening temperature reaches 325°F (162°C), turn the thermostat adjusting screw clockwise until the burner shuts off. 6. Allow the fryer to sit for a few minutes, and then slowly turn the thermostat adjusting screw counterclockwise until the burner lights. 7. Repeat Steps 5 and 6 until 325°F (162°C) is reached. A good calibration point is halfway between the lowest and highest temperature dial readings. This point should be at the 12 o'clock position. The fryer is in calibration if the burner lights at the calibration point as the shortening temperature drops - not when the burner shuts off as the temperature rises.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS





J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
7.5 Burner Gas Pressure Adjustment
1. Turn the gas valve knob to the PILOT position. 2. Remove the pressure tap plug from the end of the burner manifold. See Figure 1, Item 4. 3. Install fitting furnished with the manometer and attach manometer hose to fitting. 4. Remove the cap from the gas valve regulator adjustment screw. Turn the gas valve to the ON position. See Figure 4. 5. Increase the setting on the thermostat until the burner comes on. 6. Monitor the gas pressure reading on the manometer. 7. Adjust the gas valve regulator adjustment screw to obtain burner manifold pressure as follows:




J1C, J1X – Natural Gas – 4 in. W.C. (7.0 kPa). J1C, J1X – LP Gas – 10.0 in. W.C. (2.50 kPa). J2X – Natural Gas – 3 in. W.C. (.75 kPa). J2X – LP Gas – 8.25 in. W.C. (2.0 kPa). * Turning the screw clockwise increases pressure, counterclockwise decreases pressure.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS




J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
7.9 Alignment & Adjustment of Metal Burner Deflector
7.10 Replacing the Frypot

1. Drain all shortening from the frypot. 2. Disconnect the fryer from the gas supply. 3. If equipped, remove the frypot covers and basket hangers. 4. Remove the screws from the cowl and lift up and off the fryer. See Figure 8 and Figure 1, Item 7. 5. Remove the screws from the sides and back of the flue cap and remove the flue cap. See Figure 9. 6. Lift frypot complete with burner, gas valve, flue, drain valve, and combustion chamber from the fryer cabinet. After lifting frypot partially out of the cabinet, tilt the front of the pot up slightly to clear the drain valve. 7. Remove the burner assembly, flue, drain valve, and combustion chamber from the old frypot and install on the new frypot. 8. Reverse the previous procedures to install the new frypot assembly.


CHAPTER 8: SERVICE PARTS
8.1 Main Components


ITEM PART # COMPONENT 1 826-1015 Basket Hanger 2 210-8093 Flue Cap, J1C 3 824-1965 Top Cap/Cowl, J1C 4 810-0180 Door Handle, J1C 5 806-9562 Door, J1C 6 900-1840 Plate, Magnet Striker 7 803-0053 Adjustable Leg, J1C * Frypot, Flue, Drain Valve (see Page 8-2) * Not illustrated.

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
8.2 Frypot Components





J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
ITEM PART # COMPONENT 1 106-9762 Frypot Assembly, J1C * 806-47821 Frypot Assembly, J1X 2 806-4167SP Frypot Assembly, J2X 3 108-0842 Flue Assembly, J1C & J1X 4 806-0289 Flue Assembly, J2X 5 812-0401 Insulation, Flue Front 6 812-0392 Insulation, Flue Upper 7 806-7915 Drain Valve, J1C & J1X (Full Assembly) 810-1338 Valve, 1" Ball 810-1568 Handle, Drain Valve 8 806-8135 Drain Valve, J2X (Full Assembly) 810-1020 Valve, 1 ¼" Ball 806-8137 Bracket, Drain Switch 810-0820 Handle, Drain Valve 816-0211 Sleeve, 1 ¼" Valve Handle 809-0237 Nut, 4-40 Keps Hex with External Teeth 816-0220 Insulation, Switch 809-0540 Nut, ½-13 Hex, 2-Way Locking, Zinc Plated 901-2348 Cover, Safety Switch 807-2103 Microswitch, Micro Straight Lever

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
8.3 Burner Components
J2X Burner Manifold Assembly

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
ITEM PART # COMPONENT 1 810-0691 Vent Tube 2 Gas Valve 826-1579 Millivolt Gas Valve, Honeywell, Natural 826-1580 Millivolt Gas Valve, Honeywell, Propane 3 810-0703 Pilot Tubing, Gas Valve to Pilot 4 900-1033 Pilot Mounting Bracket, J1C & J1X 5 900-1032 Pilot Mounting Bracket, J2X 6 Pilot Assembly 810-2071 Pilot Assembly, Natural 810-1773 Pilot Assembly, Propane 810-1831 Pilot Assembly, Manufactured Gas 7 Burner Orifice 810-0131 Burner Orifice, #56, 1.30 mm, Natural, J1C & J1X 810-0129 Burner Orifice, #51, 1.70 mm, Natural, J2X 810-0140 Burner Orifice, #67, .81 mm, Propane, J1C & J1X 810-0134 Burner Orifice, #59, 1.05 mm, Propane, J2X 810-1154 Burner Orifice, 2.80 mm, Manufactured Gas, J2X 8 823-0244 Burner Manifold, J1C & J1X 9 810-1862 Burner Manifold, J2X 10 230-1178 Deflector, Side, J2X 11 230-1180 Deflector, Rear, J2X 12 230-1568 Deflector, J1C & J1X 13 200-0173 Bracket, Manifold Mounting, J2X

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
8.4 Accessories


ITEM PART # COMPONENT 1 Basket 803-0019 Twin Basket, J1C & J1X 803-0271 Twin Basket, J2X 2 Basket Support Rack 803-0030 Basket Support Rack, J1C & J1X 803-0032 Basket Support Rack, J2X 3 803-0197 Frypot Cleanout Rod 4 810-0069 Quick Disconnect, ½" Male 5 810-0071 Quick Disconnect, ½" Female 6 Flexible Gas Line 810-0081 Flexible Gas Line, ½" x 36" 810-0082 Flexible Gas Line, ½" x 48" * 812-1227 Drain Nipple * Not illustrated.


J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
8.5 Thermostat Components
ITEM PART # COMPONENT 1 806-0138 Thermostat Assembly Kit (includes Items 2 and 3) 2 806-0087 Thermostat Dial Plate Assembly 3 810-0110 Thermostat Knob 4 826-1177 High-limit Thermostat Kit




Frymaster L.L.C, 8700 Line Avenue, Shreveport, Louisiana 71106
TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 FAX (Tech Support) 1-318-219-7135
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Thermostat does not call for heat (does not energize gas control valve at all). | A. Thermostat wires damaged or broken. B. Thermostat set too low. C. Thermostat out of calibration. D. Thermostat contacts burned and pitted. | A. Repair or replace thermostat wires. B. Increase thermostat setting. C. Recalibrate the thermostat. D. Replace the thermostat. | p.26 |
| Thermostat does not control at set point. | A. Thermostat out of calibration. B. Thermostat contacts contaminated. | A. Recalibrate the thermostat. B. Replace the thermostat. | p.26 |
| Burner does not light. | A. Pilot is not lit. B. Drain valve is not fully closed. (J2X) C. No gas being supplied to unit. | A. Light pilot per instructions in Chapter 3 of this manual. B. Verify that unit is correctly plugged in and that circuit breaker is not tripped. C. Verify that the gas line connections are properly connected, that any cutoff valves between the fryer and the gas main are open, and that the main gas cutoff valve is open. | p.26 |
| Main burner will not come on. Pilot remains lit. | A. Loose, dirty, or corroded terminals on gas valve. B. High resistance in contacts of thermostat. C. Thermostat out of calibration. D. Automatic gas valve defective. E. Automatic gas valve knob turned to PILOT position. | A. Clean and tighten terminals on gas valve and thermostat. B. Replace thermostat. C. Calibrate thermostat. D. Replace gas valve. E. Turn gas valve knob to ON position. | p.27 |
| Main burner does not light all the way around. | A. Rear burner flame deflector broken off. B. Burner gas pressure too high or too low. C. One or more main burner orifices clogged. D. Fryer flue connected directly to vent hood with a chimney-like duct. | A. Install new rear burner flame deflector. B. Adjust gas pressure. J1C & J1X: Natural Gas – 4 in. W.C. (1.0 kPa). LP Gas – 10.0 in. W.C. (2.50 kPa). J2X: Natural Gas – 3 in. W.C. (.75 kPa). LP Gas – 8.25 in. W.C. (2.0 kPa). C. Clean burner orifices and blow out with compressed air. D. Remove chimney-like duct and allow for at least 18" (46 cm) between flue outlet and vent hood filters. | p.27 |
| Fryer is operating normally, but flames are rolling out of the front of the burner. | Obstructed gas valve vent tube. | Shut the fryer down and clean the gas valve vent tube in accordance with the instructions on Page 5-3 of this manual. | p.27 |
Owners and our team usually reply within a day — and your question helps the next person too.