Table of Contents 18 sections OPERATOR’S MANUAL HEATED LANDING ZONE (HLZ) · DANGER Safe and satisfactory operation of your equipment depends on its proper · (USA); Canadian Electrical Code Part 1, CSA-C22.1; or European Community · grounded three-prong outlet. DO NOT CUT OR REMOVE THE GROUNDING · … ShowHide
Page 1 of the Frymaster HLZ user manual
Page 1 · click to enlarge
Page 1
Page 1 of the Frymaster HLZ user manual
Page 2 of the Frymaster HLZ user manual — DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS/LIQUIDS
Page 2 · click to enlarge
Page 2

OPERATOR’S MANUAL HEATED LANDING ZONE (HLZ)

THIS OPERATOR’S MANUAL SUPERCEDES ALL PREVIOUS EDITIONS OF THE HLZ OPERATOR’S MANUAL.

FOR YOUR SAFETY, DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND NEAR THIS OR ANY OTHER APPLIANCE.

Frymaster HLZ — OPERATOR’S MANUAL HEATED LANDING ZONE (HLZ) diagram (page 2)
Fig. 1

DANGER Safe and satisfactory operation of your equipment depends on its proper

Installation must conform to local codes or, in the absence of local codes, with the latest edition of your national electrical code, i.e. National Electrical Code, NFPA 70

(USA); Canadian Electrical Code Part 1, CSA-C22.1; or European Community

If this appliance is equipped with a three-prong grounding plug for your protection against electrical shock, it must be plugged directly into a properly

grounded three-prong outlet. DO NOT CUT OR REMOVE THE GROUNDING

THIS APPLIANCE IS INTENDED FOR INDOOR USE ONLY. IT IS NOT SUITABLE

FOR OUTDOOR USE.

DO NOT USE WATER JETS TO CLEAN THIS EQUIPMENT. THE EQUIPMENT WILL

BE DESTROYED AND ALL WARRANTIES VOIDED.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS/LIQUIDS

NEAR ANY COOKING APPLIANCE.

Frymaster HLZ — DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS/LIQUIDS diagram (page 2)
Fig. 2

HAZARD COMMUNICATION STANDARD, (HCS) - THE PROCEDURES IN THIS MANUAL INCLUDE THE USE OF CHEMICAL PRODUCTS. THESE CHEMICAL

PRODUCTS WILL BE PRINTED IN BOLD FACE, FOLLOWED BY THE ABBREVIATION (HCS) IN THE TEXT PORTION OF THE PROCEDURE. SEE THE HAZARD COMMUNICATION STANDARD (HCS) MANUAL FOR THE APPROPRIATE

Page 3 of the Frymaster HLZ user manual — HEATED LANDING ZONE CHAPTER 1: WARRANTY INFORMATION
Page 3 · click to enlarge
Page 3

HEATED LANDING ZONE CHAPTER 1: WARRANTY INFORMATION

The Frymaster Corporation makes the following limited warranties to the original purchaser only for this equipment and its replacement parts: 1.1 Warranty Provisions – Heated Landing Zone (HLZ) A. The Frymaster Corporation warrants all components against defects in material and workmanship for a period

of 1 year. B. All parts, with the exception of fuses, are warranted for 1 year after installation date of cabinet. C. If any parts, except fuses, become defective during the first year after installation date, Frymaster will also pay

straight-time labor costs to replace the part, plus up to 100 miles/160 km of travel (50 miles/80 km each way). 1.2 Parts Return All defective in-warranty parts must be returned to a Frymaster Authorized Factory Service Center within 60 days for credit. After 60 days, no credit will be allowed. 1.3 Warranty Exclusions This warranty does not cover equipment that has been damaged due to misuse, abuse, alteration, or accident such as:

  • improper or unauthorized repair;
  • failure to follow proper installation instructions and/or scheduled maintenance procedures as prescribed in your MRC cards;
  • improper maintenance;
  • damage in shipment;
  • abnormal use;
  • removal, alteration, or obliteration of the rating plate; This warranty also does not cover:
  • transportation or travel over 100 miles/160 km (50 miles/80 km each way), or travel time over two (2) hours;
  • overtime or holiday charges;
  • consequential damages (the cost of repairing or replacing other property which is damaged), loss of time, profits, use or any other incidental damages of any kind. There are no implied warranties or merchantability or fitness for any particular use or purpose. For international warranty, the above procedures apply, except that the customer is responsible for freight and duty charges.
Page 4 of the Frymaster HLZ user manual — HEATED LANDING ZONE CHAPTER 2: PARTS/SERVICE INFORMATION
Page 4 · click to enlarge
Page 4

HEATED LANDING ZONE CHAPTER 2: PARTS/SERVICE INFORMATION

2.1 Ordering Parts Parts orders may be placed directly with your local Frymaster Factory Authorized Service Center (FASC)/distributor. A list of Frymaster FASCs/distributors was included with the unit when shipped. If you do not have access to this list, please contact the Frymaster Service Department at 1-800-24-FRYER or 1-318-865- 1711. To speed up your order, the following information is required: Model Number Serial Number Voltage Item Part Number Quantity Needed 2.2 Service Information Service may be obtained by contacting your local Frymaster Authorized Service Center/Distributor. Service information may be obtained by calling the Frymaster Service Department. The following information will be needed in order to assist you quickly and efficiently: Model Number Serial Number Nature of the Problem

Additional information (i.e. cooking environment, time of day) may be helpful in solving your service

problem. Contact your service technician.

RETAIN AND STORE THIS MANUAL IN THE EQUIPMENT MANUAL FOR FUTURE USE.

Page 5 of the Frymaster HLZ user manual — HEATED LANDING ZONE CHAPTER 3: INSTALLATION AND OPERATION
Page 5 · click to enlarge
Page 5

HEATED LANDING ZONE CHAPTER 3: INSTALLATION AND OPERATION

The Heated Landing Zone or HLZ is designed to hold assembled sandwiches. By circulating heated air evenly across the open staging area, the Heated Landing Zone keeps sandwiches hot without drying or cooking. The Heated Landing Zone meets all McDonald’s standards for safety, efficiency, food safety, and cleanliness. 3.1 HLZ Installation/Setup

Upon arrival, inspect the HLZ for concealed damage. Immediately report any damage to the delivering freight company. Claims must be filed within 15 days after receipt of the unit. Make sure that the unit is placed on an even surface and that the area surrounding the HLZ is free of clutter that would interfere with airflow.

Install Optional Burger Bumper (Units Built Before 10/98) The burger bumper may be placed on either side of the HLZ to prevent pass through of product. Burger bumpers are provided by the KES. See Figure 1.

Frymaster HLZ — HEATED LANDING ZONE CHAPTER 3: INSTALLATION AND OPERATION diagram (page 5)
Fig. 3

Install Filter Screen (Units Built After 10/98) The filter screen is design to prevent debris from entering the computer Cowl Assembly and clogging the blower assembly. Simply fit the part on to the vent opening of the computer cowl assembly. The filter screen will snap into position. If equipped with an optional holding screw, tighten screw to pull the filter screen snug into position.

Frymaster HLZ — HEATED LANDING ZONE CHAPTER 3: INSTALLATION AND OPERATION diagram (page 5)
Fig. 4

Power Requirements • Voltage – Two models are available: 208 VAC and 240 VAC*

The filter screen snaps into place on rear of the air-intake tower.

  • Frequency - 60 Hz
  • Single Phase
  • 20 amp Service

3.2 HLZ Operation 1. Plug the unit into the power source. 2. See Chapter 5, Computer Operation and Programming, for proper computer setup and operation. 3. Place product in the HLZ in accordance with the restaurant’s established procedures. 4. When closing the store, remove all product from the HLZ and perform daily preventive maintenance in accordance with the MRC. Turn the computer OFF.

ALL UNITS (CORD CONNECTED OR PERMANENTLY CONNECTED) SHOULD BE CONNECTED TO A GROUNDED POWER SUPPLY SYSTEM.

THIS APPLIANCE IS EQUIPPED WITH A GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND MUST BE PLUGGED INTO A PROPERLY GROUNDED RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG.

Show 4 more labels / short text on this page
Optional Burger Bumper · Installed (before 10/98) · Computer · Cowl
Page 6 of the Frymaster HLZ user manual — HEATED LANDING ZONE CHAPTER 4: HLZ MODEL/COMPONENT IDENTIFICATION
Page 6 · click to enlarge
Page 6

HEATED LANDING ZONE CHAPTER 4: HLZ MODEL/COMPONENT IDENTIFICATION

Heater Plate/ Landing Zone

Heated air flows from the air heater/blower and heat rises from the heater plate.

Frymaster HLZ — HEATED LANDING ZONE CHAPTER 4: HLZ MODEL/COMPONENT IDENTIFICATION diagram (page 6)
Fig. 5
Frymaster HLZ — HEATED LANDING ZONE CHAPTER 4: HLZ MODEL/COMPONENT IDENTIFICATION diagram (page 6)
Fig. 6

Heater Plate Calibration Socket

Air Heater Calibration Socket

A look at the flow of heated air around the HLZ

Show 6 more labels / short text on this page
HLZ Computer · Power Cord · Blower Assembly · Heater plate · Heater Plate · Air Heater
Page 7 of the Frymaster HLZ user manual — HEATED LANDING ZONE CHAPTER 5: COMPUTER OPERATION AND PROGRAMMING
Page 7 · click to enlarge
Page 7

HEATED LANDING ZONE CHAPTER 5: COMPUTER OPERATION AND PROGRAMMING

Frymaster HLZ — HEATED LANDING ZONE CHAPTER 5: COMPUTER OPERATION AND PROGRAMMING diagram (page 7)
Fig. 7

Heater Plate Temperature Switch (1)

Air Heater Temperature Switch (4)

Check or Program Switch

Down Switch (2) Up Switch (3)

HLZ Computer.

5.1 Programming Temperatures You are able to program the setpoint temperature of both the air heater and the heater plate via the computer interface. The heater plate factory default is set to the McDonald’s standard of 160°F. The air heater factory default is set to the McDonald’s standard of 220°F. If the factory default temperature settings are acceptable, skip to Section 7.2, Page 6. Ensure that the HLZ computer is in the OFF position (nothing in the display). Press

, then enter 1, 2, 3, 3. Use the numerals in the upper right-hand corner of each key.

. The display will read SET and the LEDs on both the Heater Plate button (1) and the Air Heater button (4) will light (see previous diagram, HLZ Computer). Press the button that corresponds to the heater you wish to program. Press the Up and Down Arrow Keys to achieve the desired set-point temperature, then press the Check button once. Both heater LEDs will again light.

to lock the temperature in. When both heaters are programmed, press

to get desired setpoint, then press

again to store the programmed setpoints and exit the

programming mode OR press either of the

buttons (1 or 4) to change the setpoint temperature for a heater. Program as previously described.

Show 9 more labels / short text on this page
Display · ON/OFF Switch · Press · , then · , · , · , · Press · or
Page 8 of the Frymaster HLZ user manual — 220F
Page 8 · click to enlarge
Page 8

HEATED LANDING ZONE CHAPTER 5: COMPUTER OPERATION AND PROGRAMMING

5.2 Operation 1. Press the power button, turning the HLZ on (the display will light and cycle through an initialization sequence). The display will read -LO- until the air heater and heater plate are within 15°F of setpoint. It will take approximately 10 minutes for the HLZ to achieve operating temperature.

to turn on the computer.

The display will read LO until both heaters are within 15° F of setpoint. When the HLZ is ready for operation, the display reads R E d y (ready). Place product in the HLZ in accordance with the restaurant’s established procedures. NOTE: To check the actual temperature of a heater, press the corresponding Temperature button once. To check the setpoint temperature of a heater, press the button twice (an indicator will light when the setpoint is displayed).

Air Heater Activation d ¡

R E y

Frymaster HLZ — Air Heater Activation d ¡ diagram (page 8)
Fig. 8 · Air Heater Activation d ¡

220F

Press · Heater Plate · Temperature Setpoint Indicator

Page 9 of the Frymaster HLZ user manual — HEATED LANDING ZONE CHAPTER 5: COMPUTER OPERATION AND PROGRAMMING
Page 9 · click to enlarge
Page 9

HEATED LANDING ZONE CHAPTER 5: COMPUTER OPERATION AND PROGRAMMING

5.3 Switching Between Fahrenheit and Celsius Temperature Scales Follow these steps to switch between Fahrenheit and Celsius temperature displays (refer to diagram, HLZ Computer, on Page 5-1):

1. Unplug unit from power supply.
2. Press and hold either temperature bulb button.
3. Plug unit back into power supply with button depressed.
4. S T O R will be shown in the display.
5. Release the temperature button.
6. Press the power button. Now, the unit will display the temperature in Celsius rather than Fahrenheit.
Page 10 of the Frymaster HLZ user manual — HEATED LANDING ZONE CHAPTER 6: OPERATOR TROUBLESHOOTING
Page 10 · click to enlarge
Page 10

HEATED LANDING ZONE CHAPTER 6: OPERATOR TROUBLESHOOTING

SymptomPossible Cause No computer display; no flow from air tower• No power • Circuit breaker out • Low voltage • Bad fuse • Bad transformer • Hi-limit out No flow from air tower• Bad latching relay After 20 minutes of operation computer display shows PROB• RTD probe has failed. Isolate failed component by checking temperature of air and heater plate with the temperature display keys on the computer. The plate temperature should be within ± 15°F of setpoint. The air heat should be within ± 25°F of setpoint. If both temperatures are good, the computer is likely bad. After 20 minutes of operation computer display shows HI• Plate heater, plate heater relay or RTD are faulty. After 20 minutes of operation computer display shows LO• Air heater, air heater relay or RTD are faulty
Page 11 of the Frymaster HLZ user manual — 819-5636 PRINTED IN THE UNITED STATES SERVICE HOTLINE
Page 11 · click to enlarge
Page 11
Frymaster HLZ — 819-5636 PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 11)
Fig. 9

Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000

Shipping Address8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 (Tech Support) 1-318-219-7135

819-5636 PRINTED IN THE UNITED STATES SERVICE HOTLINE

1-800-551-8633 APR 2005

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No computer display; no flow from air tower• No power • Circuit breaker out • Low voltage • Bad fuse • Bad transformer • Hi-limit out p.10
No flow from air tower• Bad latching relay p.10
After 20 minutes of operation computer display shows PROB• RTD probe has failed. Isolate failed component by checking temperature of air and heater plate with the temperature display keys on the computer. The plate temperature should be within ± 15°F of setpoint. The air heat should be within ± 25°F of setpoint. If both temperatures are good, the computer is likely bad. p.10
After 20 minutes of operation computer display shows HI• Plate heater, plate heater relay or RTD are faulty. p.10
After 20 minutes of operation computer display shows LO• Air heater, air heater relay or RTD are faulty p.10

Ask about the Frymaster HLZ

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster HLZ

Be the first to ask — other owners or our team will answer.

Original document

Frymaster HLZ manual PDF

11 pages·451 KB·Toaster·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…