High Efficiency Decathlon (HD) Series Gas Fryers Service & Parts Manualp.1Dean HD & SCFHD, Frymaster FPHD Modelsp.1(Includes HD63/Red Robin and Common Cabinetry)p.1MAY 2007 *8196314*p.1PRINTED IN THE UNITED STATESp.1OF AMERICAp.1damage, injury or death. Read the installation, operating and maintenance instructionsp.2ANSI Z223.1; The Natural Gas Installation Code, CAN/CGA-B149.1; The Propane Installationp.2COMPUTERSp.3FCCp.3CANADAp.3Interface Boards (cont.)p.111.7.3 Replacing the Temperature Probe; Computer-equipped Fryersp.171.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.)p.18FIGURE Bp.231.7.8 Replacing the Frypot (cont.)p.32DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVERp.35AND NOT THE BLADE. THE SPARKING CHARGE IS APPROXIMATELY 25,000p.351.9 Troubleshooting Guides (cont.)p.42Computer with Constant Pilotp.44Dean Oil Return Wiringp.46Dean Oil Return Wiring, with Solenoidp.471.11 Probe Resistance Chartsp.482.1 High Efficiency Decathlon (HD) Primary Componentsp.492.1.2 Decathlon HD60 Primary Components (includes SCFHD units) (cont.)p.532.1.3 Decathlon FPHD65 Primary Components (cont.)p.552.2 Orificesp.572.3 Control Panel Options, Joiner Strips, and Accessoriesp.582.4 Optional Components and Controllersp.592.4 Optional Components and Controllers (cont.)p.602.5 3” Oil Drain Manifold, Drain Flush, and Drain Valve Componentsp.622.5 3” Oil Drain Manifold, Drain Flush, and Drain Valve Components (cont.)p.632.6 Oil Return Manifold Componentsp.642.6 Oil Return Manifold Components (cont.)p.652.7 Oil Return and Oil Flush Componentsp.672.8 Filtration Components 2.8.1 Filtration Components; SCFHD50 Series Fryersp.692.8.2 Filtration Components; SCFHD60 and SCFHD63 Series Fryersp.702.8.3 Filtration Components; FPHD65 Series Fryersp.712.9 Basket Lift Componentsp.722.9 Basket Lift Components (cont.)p.732.10 Trough, Holster, & Cover Componentsp.742.11 Fasteners (Screws, Nuts, Bolts)p.75PRINTED IN THE UNITED STATES SERVICE HOTLINEp.761-800-551-8633 819-6314 MAY 2007p.76
Page 1 of the Frymaster FPHD user manual — PRINTED IN THE UNITED STATES
Page 1 · click to enlarge
Page 1

High Efficiency Decathlon (HD) Series Gas Fryers Service & Parts Manual

Frymaster FPHD — High Efficiency Decathlon (HD) Series Gas Fryers Service & Parts Manual diagram (page 1)
Fig. 1 · High Efficiency Decathlon (HD) Series Gas Fryers Ser…
Frymaster FPHD — High Efficiency Decathlon (HD) Series Gas Fryers Service & Parts Manual diagram (page 1)
Fig. 2 · High Efficiency Decathlon (HD) Series Gas Fryers Ser…
Frymaster FPHD — High Efficiency Decathlon (HD) Series Gas Fryers Service & Parts Manual diagram (page 1)
Fig. 3 · High Efficiency Decathlon (HD) Series Gas Fryers Ser…
Frymaster FPHD — High Efficiency Decathlon (HD) Series Gas Fryers Service & Parts Manual diagram (page 1)
Fig. 4 · High Efficiency Decathlon (HD) Series Gas Fryers Ser…
Frymaster FPHD — High Efficiency Decathlon (HD) Series Gas Fryers Service & Parts Manual diagram (page 1)
Fig. 5 · High Efficiency Decathlon (HD) Series Gas Fryers Ser…

Dean HD & SCFHD, Frymaster FPHD Models

(Includes HD63/Red Robin and Common Cabinetry)

Dean, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

24-Hour Service Hotline 1-800-551-8633

MAY 2007 *8196314*

PRINTED IN THE UNITED STATES

OF AMERICA

Page 2 of the Frymaster FPHD user manual — ANSI Z223.1; The Natural Gas Installation Code, CAN/CGA-B149.1; The Propane Installation
Page 2 · click to enlarge
Page 2

Please read all sections of this manual and retain for future reference.

This product has been certified as commercial cooking equipment and MUST be installed by professional personnel as specified. Installation, maintenance and repairs should be performed

by your FRYMASTER FACTORY AUTHORIZED SERVICE CENTER.

other cooking appliance.

Frymaster FPHD — damage, injury or death. Read the installation, operating and maintenance instructions diagram (page 2)
Fig. 6 · damage, injury or death. Read the installation, oper…
Frymaster FPHD — damage, injury or death. Read the installation, operating and maintenance instructions diagram (page 2)
Fig. 7 · damage, injury or death. Read the installation, oper…

WARNING Improper installation, adjustment, alteration, service or maintenance can cause property

damage, injury or death. Read the installation, operating and maintenance instructions

thoroughly before installing or servicing this equipment.

Frymaster FPHD — WARNING Improper installation, adjustment, alteration, service or maintenance can cause property diagram (page 2)
Fig. 8 · WARNING Improper installation, adjustment, alteratio…

ANSI Z223.1; The Natural Gas Installation Code, CAN/CGA-B149.1; The Propane Installation

Code, CAN/CGA-B149.2; or The latest edition of the National Electric Code, N.F.P.A. 70.

unmodified new or recycled part purchased directly from Frymaster and Dean, or any of its

authorized service centers, and/or the part being used is modified from its original configuration, this warranty will be void. Further, Frymaster and Dean and its affiliates will not be liable for any claims, damages or expenses incurred by the customer which arise directly or

indirectly, in whole or in part, due to the installation of any modified part and/or part received

from an unauthorized service center.

Frymaster FPHD — ANSI Z223.1; The Natural Gas Installation Code, CAN/CGA-B149.1; The Propane Installation diagram (page 2)
Fig. 9 · ANSI Z223.1; The Natural Gas Installation Code, CAN/…

at the end of frying operations each day. Some food particles can spontaneously combust if left

soaking in certain shortening material. Additional information can be obtained in the filtration

from slips or contact with the hot oil.

Page 3 of the Frymaster FPHD user manual — CANADA
Page 3 · click to enlarge
Page 3

technical procedures and may not conform to on-site management operational procedures.

Frymaster FPHD — COMPUTERS diagram (page 3)
Fig. 10

the fryer under a hood. Questions? Call the Frymaster and Dean Service Hotline at 1-800-551-

This equipment is to be installed in compliance with the basic plumbing code of The Building

Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation

Manual of the Food and Drug Administration.

COMPUTERS

FCC

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

1. This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class

A device, it has been shown to meet the Class B limits.

CANADA

This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the

ICES-003 standard of the Canadian Department of Communications.

Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B

prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.

Frymaster FPHD — CANADA diagram (page 3)
Fig. 11

CANCER AND/OR BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne

particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other

reproductive harm.

Frymaster FPHD — CANADA diagram (page 3)
Fig. 12

the joint between the fry vessels. Banging fry baskets on the strip to dislodge shortening will

distort the strip, adversely affecting its fit. It is designed for a tight fit and should only be

Page 4 of the Frymaster FPHD user manual — COMPUTERS
Page 4 · click to enlarge
Page 4
Page 4 of the Frymaster FPHD user manual — COMPUTERS
Page 5 of the Frymaster FPHD user manual — COMPUTERS
Page 5 · click to enlarge
Page 5
Page 5 of the Frymaster FPHD user manual — COMPUTERS
Page 6 of the Frymaster FPHD user manual — COMPUTERS
Page 6 · click to enlarge
Page 6

1.1 Functional Description High Efficiency Decathlon (HD) Series gas fryers contain a welded stainless steel frypot heated by gas flames diffused evenly through tubes built into the frypot. Flames originate from orifices in a burner manifold positioned beneath stamped-steel burners. The burners are positioned in the tube openings at the front of the frypot. The diameter of the orifices differs for natural and LP gas as indicated in the accompanying table.

Frymaster FPHD — COMPUTERS diagram (page 6)
Fig. 13
Frymaster FPHD — COMPUTERS diagram (page 6)
Fig. 14
Frymaster FPHD — COMPUTERS diagram (page 6)
Fig. 15
Frymaster FPHD — COMPUTERS diagram (page 6)
Fig. 16

High efficiency burner and diffuser.

Frymaster FPHD — COMPUTERS diagram (page 6)
Fig. 17
GAS INFORMATION (Altitudes of 2000 feet or less) MODELINPUT (BTU)GAS TYPEORIFICE MM (INCH)ORIFICE PART NO.QTYEQUIPMENT PRESSURE MBARINCH W.C. HD50G95NAT LP2.26(#43) 1.40(#54)810-2938 810-29394 410 27.54 10 HD60G125NAT LP2.26(#43) 1.40(#54)810-2938 810-29395 510 27.54 10

An electromechanical gas valve regulates gas flow to the manifold. HD Series gas fryers are equipped with either a 24V valve system. Unit configurations include either a pilot ignition system or an electronic ignition system.

Page 7 of the Frymaster FPHD user manual — COMPUTERS
Page 7 · click to enlarge
Page 7

1.1 Functional Description (cont.) Pilot System Configuration The pilot system is comprised of the pilot orifice, pilot hood, and a thermopile (some systems incorporate a thermocouple). The pilot serves two purposes: light the burner and heat the thermopile. In operation, the thermopile is in contact with the pilot flame and generates millivolts. The millivolt output energizes the gas valve pilot coil, which in turn opens the pilot valve. If the pilot flame is extinguished, the gas valve pilot coil loses voltage and the pilot valve closes. The main valve of the gas valve will not open if the pilot valve is not open. The pilot flame must be manually lit when the fryer is first placed into operation. A separate 24V circuit, activated by the fryer ON/OFF switch, provides voltage through the Thermatron to the gas valve main coil, which opens the main valve.

Frymaster FPHD — COMPUTERS diagram (page 7)
Fig. 18

Electronic Ignition Configuration In units configured for electronic ignition, an ignition module connected to an ignitor assembly replaces the pilot system. The ignition module performs three important functions: It provides an ignition spark, supplies voltage to the gas valve, and proofs the pilot flame. The module contains a 90-second time delay circuit and a coil that activates the gas valve. The ignitor assembly consists of a spark plug, a pilot, and a flame sensor element.

Page 8 of the Frymaster FPHD user manual — COMPUTERS
Page 8 · click to enlarge
Page 8

Electronic Ignition Configuration (cont.) At start-up the ON/OFF switch is placed in the ON position, supplying 12 VDC to the heat control circuitry in the controller or computer and to one side of the heat relay coil on the interface board. If resistance in the temperature probe indicates the temperature in the frypot is below 180°F (82°C), the current flows through a melt cycle circuit where a timer switch alternately closes for 3 seconds and opens for 24 seconds. If the temperature is 180°F (82°C) or above, the current flows through a heat circuit, bypassing the timer switch. In either case, current is supplied to the other leg of the heat relay coil which then closes an electronic switch in the 24 VAC circuit to provide current to the ignition module. NOTE: The listed melt cycle times and exit temperature pertain to the Compu-Fry computer only. Circuitry in the ignition module sends 24 VAC current to the gas valve via a normally closed high- limit switch and a drain safety switch. Simultaneously, the module causes the ignitor to spark for up to 90 seconds to light the pilot flame. A flame sensor verifies that the pilot is lit by measuring the flow of microamps through the flame. If the pilot does not light (or is extinguished), current to the ignition module is interrupted, preventing the main valve from opening, and the ignition module "locks out" until the power switch is turned OFF, then back ON. A temperature probe monitors the temperature in the frypot. When the programmed setpoint temperature is reached, resistance in the probe causes the heat cycle circuitry in the controller to interrupt current flow through the heat relay. This in turn interrupts the 24 VAC current to the ignition module, resulting in closure of the gas valve. NOTE: Unlike previous modules, microamp readings on these black modules will move up and down as the module pulses on and off and this is an indication that the module is functioning. Control Options HD Series gas fryers may be equipped with Thermatron controls or Compu-Fry computers. In fryers equipped with Thermatron controls, the fryer is turned on and off by means of a rocker switch and the temperature is set by adjusting a potentiometer. An interface board is located in the component box (shield) behind the control panel (computer-equipped) or a Thermatron board is located in a component box inside the cabinet (Thermatron-equipped). Interface Boards The interface board provides a link between the controller/computer and the fryer’s individual components without requiring excessive wiring, and allows the controller to execute commands from one central point. Two types of interface boards may be used in HD Series gas fryers; the type used depends on the fryer configuration. In units configured for electronic ignition and constant pilot, P/N 106-6669 is used; in units configured with a manually lit pilot (non-electronic ignition), P/N 106-6710 is used.

Page 9 of the Frymaster FPHD user manual — COMPUTERS
Page 9 · click to enlarge
Page 9

Interface Boards (cont.) 826-2086 (115/230V): These boards are used in HD fryers equipped with Thermatron control systems.

Frymaster FPHD — COMPUTERS diagram (page 9)
Fig. 19

Thermatron systems incorporate a temperature probe, a potentiometer, and a temperature control circuit board. This system is more accurate and reliable than a standard thermostat. The temperature probe measures oil temperature via resistance (ohms); as oil temperature rises, resistance decreases. The potentiometer sets the oil temperature via resistance (ohms). The temperature control circuit board compares the resistance from the probe and potentiometer and cycles the burner on and off as necessary.

Page 10 of the Frymaster FPHD user manual — COMPUTERS
Page 10 · click to enlarge
Page 10

Interface Boards (cont.) 826-2434: These interface boards are used in HD fryers equipped with electronic ignition and constant pilot.

Frymaster FPHD — COMPUTERS diagram (page 10)
Fig. 20

INTERFACE BOARD P/N 106-6669 (Kit 826-2434) Used on fryers equipped with electronic ignition and constant pilot.

Page 11 of the Frymaster FPHD user manual — Interface Boards (cont.)
Page 11 · click to enlarge
Page 11

Interface Boards (cont.)

Frymaster FPHD — Interface Boards (cont.) diagram (page 11)
Fig. 21 · Interface Boards (cont.)
FREQUENTLY USED TEST POINTS FOR HIGH EFFICIENCY DECATHLON (HD) FRYERS 106-6669 INTERFACE BOARD TestMeter SettingPinsTest Results 12VAC Power to Controller50 VAC Scale1 and 3 on J312-18 12VDC Power to Right BL Relay50 VDC Scale4 on J2 and 5 on J212-18 12VDC Power to Left BL Relay50 VDC Scale7 on J1 and 5 on J212-18 24VAC Power to High-Limit50 VAC Scale6 on J2 and GROUND22-28 24VAC Power50 VAC Scale2 on J2 and GROUND22-28 24VAC Power To 24VAC Gas Valve50 VAC Scale7 on J2 and GROUND22-28 Probe Resistance*R x 1000 Ohms10 and 11 on J2** * Disconnect 15-pin harness from controller before testing probe circuit. ** See Probe Resistance Chart at the end of this chapter.
Frymaster FPHD — Interface Boards (cont.) diagram (page 11)
Fig. 22 · Interface Boards (cont.)
HIGH EFFICIENCY DECATHLON (HD) FRYER LED DIAGNOSTIC LIGHTS (106-6669 INTERFACE BOARD) CMPIndicates power from 12V transformer. 24VIndicates power from 24V transformer. HIIndicates output (closed) from latch relay (K4). HTIndicates output from heat relay (K3). ALIndicates output (open) from latch relay (K4).
Page 12 of the Frymaster FPHD user manual — Interface Boards (cont.)
Page 12 · click to enlarge
Page 12

Thermostats Different types of thermostats are used in High Efficiency Decathlon Series gas fryers, depending on fryer configuration. Fryers equipped with a Thermatron use a dial to adjust temperature. In this configuration, the probe resistance varies inversely with the temperature. As the temperature rises, resistance decreases at a non-linear rate. A chart is located at the end of this chapter. Fryers equipped with computer controls have a temperature probe. In this configuration, the probe resistance varies directly with the temperature. As the temperature rises, resistance increases at a rate of approximately 2 ohms for every 1°F (approximately 3.7 ohms for every 1°C). Circuitry in the computer monitors the probe resistance and controls burner firing when the resistance exceeds or falls below programmed temperatures (setpoints). The temperatures are programmed by means of a keypad on the face of the computer. All HD Series gas fryers are equipped with a high-limit thermostat. In the event that the fryer fails to control the oil temperature, the high-limit thermostat prevents the fryer from overheating to flash point. The high-limit thermostat acts as a normally closed power switch that opens when exposed to temperatures above 450°F/232°C. 1.2 Accessing Fryers for Servicing

relocate a fryer for servicing. 1. Shut off the gas supply to the unit. Unplug the power cords. Remove any attached restraining devices. 2. Disconnect the unit from the gas supply. 3. Relocate the fryer for service accessibility. 4. After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and plug in the electrical cords.

Hotline at 1-800-551-8633.

Page 13 of the Frymaster FPHD user manual — Interface Boards (cont.)
Page 13 · click to enlarge
Page 13

Restraints Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the top of the frypot to verify that the unit is level, both side-to-side and front-to-back. To level fryers equipped with legs, the bottom of the legs can be screwed out up to one inch for leveling. Legs should also be adjusted so that the fryer(s) are at the proper height in the frying station. For fryers equipped with casters, there are no built-in leveling devices. The floor where the fryers are installed must be level. When the fryer is leveled in its final position, install the restraints provided with the unit to limit its movement so that it does not depend on or transmit stress to the electrical conduit or connection. Install the restraints in accordance with the provided instructions (see illustration below). If the restraints are disconnected for service or other reasons, they must be reconnected before the fryer is used.

Page 14 of the Frymaster FPHD user manual — Interface Boards (cont.)
Page 14 · click to enlarge
Page 14

1.3 Cleaning the Gas Valve Vent Tube (if applicable) 1. Set the fryer power switch and the gas valve to the OFF position. 2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease in removal. 3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any obstruction. Remove the wire and blow through the tube to ensure it is clear. 4. Reinstall tube and bend so that the opening is pointing downward. 1.4 Adjusting Burner Manifold Gas Pressure

2. Remove the pressure tap plug from the gas valve (see arrows in photos below for location).
3. Insert the manometer fitting into the pressure tap hole.
Frymaster FPHD — Interface Boards (cont.) diagram (page 14)
Fig. 23 · Interface Boards (cont.)
Frymaster FPHD — Interface Boards (cont.) diagram (page 14)
Fig. 24 · Interface Boards (cont.)

Electronic Ignition Valve Pilot Ignition Valve

4. Place the gas valve in the ON position then place the fryer power switch in the ON position. When the burner lights and continues to burn, check the gas pressure reading against the table on page 1-1.
5. To adjust burner gas pressure, remove the cap from the gas valve regulator and adjust to correct pressure.
6. Place the fryer power switch and the gas valve in the OFF position. Remove the manometer fitting from the pressure tap hole and reinstall the pressure tap plug.

(Line Voltage)

Page 15 of the Frymaster FPHD user manual — Interface Boards (cont.)
Page 15 · click to enlarge
Page 15

1.5 Adjusting the Pilot Flame 1.5.1 Main Pilot 1. Remove the cap from the pilot adjustment screw hole on the gas valve. 2. Using a small, flat-tipped screwdriver, turn the pilot adjusting screw counterclockwise to increase length of flame or clockwise to decrease length of flame. Adjust to obtain a flame from 1 inch to 1½ inches long. 3. Reinstall the pilot adjustment screw cap. 1.5.2 Trailing Pilot Unlike older Decathlon units, current production HD units do not have a trailing pilot adjustment. 1.6 Calibrating the Thermatron 1. Fill the frypot to the lower OIL-LEVEL line with cooking oil. If solid shortening is used, it must be melted before starting the calibration procedure. 2. Ensure the fryer ON/OFF switch is in the OFF position and light the pilot. 3. Place the fryer ON/OFF switch in the ON position. Set the potentiometer dial to 325°F (162°C). 4. Allow the oil to equalize at setpoint temperature. This is evident when the burners have cycled on and off several times. 5. Insert a thermometer or pyrometer into the frypot within 3 inches of the probe bulb. Ensure the tip of the thermometer/pyrometer does not touch the frypot burner tube. 6. If the temperature on the thermometer is higher or lower than 325°F (162°C), the knob is out of calibration. 7. Calibrate the knob by first loosening the setscrew and slowly turning the knob to match the temperature reading of the thermometer. Tighten the setscrew, ensuring the knob does not move on the shaft during tightening. 8. Allow burners to cycle on and off several times, then recheck oil temperature as described in Step 5. If the thermostat dial temperature matches the thermometer temperature, the thermostat is calibrated. If not, repeat Step 7.

Page 16 of the Frymaster FPHD user manual — Interface Boards (cont.)
Page 16 · click to enlarge
Page 16

1.7 Replacing Fryer Components 1.7.1 Replacing the Computer 1. Disconnect the fryer from the electrical supply. 2. Unscrew the two computer panel screws. The computer panel is hinged at the bottom and will swing open from the top. 3. Unplug the fryer wiring harness and ground wire from the back of the computer. 4. Remove the computer by lifting it from the hinge slots in the fryer control panel frame. 5. Reverse the procedure to install a new computer.

Frymaster FPHD — Interface Boards (cont.) diagram (page 16)
Fig. 25 · Interface Boards (cont.)

Computer panel in “down” position.

Frymaster FPHD — Interface Boards (cont.) diagram (page 16)
Fig. 26 · Interface Boards (cont.)

Disconnect the 15-pin connector and ground wire (arrows) from the computer.

Page 17 of the Frymaster FPHD user manual — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers
Page 17 · click to enlarge
Page 17

1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers

1. Disconnect the fryer from the electrical supply.
2. Drain cooking oil from the frypot. Allow the frypot to cool completely before proceeding.
3. Remove fryer door for easier access to the temperature probe. First, remove top hinge from bracket. Then, lift door off bottom hinge pin.

Remove the fryer door for easier access to the temperature probe.

4. Disconnect the probe harness connector (arrow). Use a pin pusher to remove plug from probe wires (probe side only). Retain the plug for re-assembly on new probe.

Disconnect the two-pin probe harness connector (arrow).

5. Remove the drain manifold. Only the drain tubes directly blocking the frypot being replaced require removal. - Remove the nuts holding the drain valve strap onto the drain tube stud. - Disconnect the Teflon tube at the back of the center dump tube piece and any other components attached to the tubes, including drain flush flexlines.

- Loosen the nut on each clamp holding the rubber boots and drain sections together.

Remove the nuts, Teflon tube (not pictured), clamp, boot, and drain tubes.

- Carefully remove the tubes by pulling down at an angle, straight out of the drain valves, and working them gently out of the rubber boots. Set aside for reassembly.

Page 18 of the Frymaster FPHD user manual — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.)
Page 18 · click to enlarge
Page 18

1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.)

6. Remove the burner shield by loosening the screw on each end. 7. Remove the burner rail by loosening the screw on each end. The burner rail secures the burners in the burner manifold. Be careful to ensure that the burners do not fall out of the gas manifold, as they might be damaged and dented.

Remove the burner rail and burner shield.

8. Remove the burners to gain access to the temperature probe and to ease frypot removal. Lean each burner slightly away from the frypot to clear the burner seal (metal box attached to frypot). Then, pull the burner up and off of the orifice. The burners should be easy to remove and do not require force.
Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 18)
Fig. 27 · 1.7.3 Replacing the Temperature Probe; Computer-equi…
Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 18)
Fig. 28 · 1.7.3 Replacing the Temperature Probe; Computer-equi…
Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 18)
Fig. 29 · 1.7.3 Replacing the Temperature Probe; Computer-equi…
Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 18)
Fig. 30 · 1.7.3 Replacing the Temperature Probe; Computer-equi…

Remove burners to gain access to temperature probe (arrow).

Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 18)
Fig. 31 · 1.7.3 Replacing the Temperature Probe; Computer-equi…
9. Loosen and unscrew the compression nut and the pass-through nut completely from the frypot. Proceed to the next step before removing the probe from the frypot.

Loosen and unscrew completely the compression nut (bottom arrow), then the pass-through nut (top arrow).

Page 19 of the Frymaster FPHD user manual — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.)
Page 19 · click to enlarge
Page 19

1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) 10. Locate the temperature probe inside the frypot. Remove the temperature probe mounting hardware. Retain mounting hardware for installation of new temperature probe. 11. The temperature probe can be removed through the bottom of the frypot as follows: Ensure the two-pin connector has been removed from the probe wiring harness (step 4, above). Remove the harness insulation. The probe can be pulled through the frypot from the bottom (complete step 7, above, prior to removing probe).

Locate the temperature probe.

Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 19)
Fig. 32 · 1.7.3 Replacing the Temperature Probe; Computer-equi…

After removing the probe mounting hardware, the temperature probe can be removed through the bottom of the frypot. Retain the mounting hardware for reassembly.

12. Carefully remove the probe from the frypot. As the probe is removed, tilt the probe at an angle to facilitate removal (curved probes only).
13. Follow the steps on the next page to install the new temperature probe. IMPORTANT: When installing new probe, use Loctite PST567 or equivalent pipe thread sealant on threads and ensure probe is positioned properly with the mounting hardware installed prior to tightening the compression nut . Once tightened, the probe cannot be repositioned.
Page 20 of the Frymaster FPHD user manual — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.)
Page 20 · click to enlarge
Page 20

Installing the New Temperature Probe: 1. Feed the probe wire through the probe nipple from the top side of the frypot. 2. Loosely install the bladder nut. 3. Mount the probe into the mounting hardware. 4. Tighten the bladder nut. 5. Install the insulation and plug. 1.7.4 Replacing the High-limit Thermostat 1. Turn fryer off and drain oil from the frypot. Allow the frypot to cool completely before proceeding. 2. Perform steps 1-4 in Section 1.7.1, Replacing the Computer. 3. Remove fryer door for easier access to the temperature probe. First, remove top hinge from bracket. Then, lift door off bottom hinge pin. 4. Remove two screws securing the high-limit mounting-bracket. Do not disconnect wires from high-limit at this time. 5. Loosen and completely unscrew the compression nut, then the pass-through nut on the frypot bottom. Proceed to the next step before removing high-limit from frypot.

Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 20)
Fig. 33 · 1.7.3 Replacing the Temperature Probe; Computer-equi…

Remove screws (arrows) securing high-limit to fryer.

Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 20)
Fig. 34 · 1.7.3 Replacing the Temperature Probe; Computer-equi…

Compression nut unscrewed. Unscrew the pass-through nut (arrow).

Page 21 of the Frymaster FPHD user manual — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.)
Page 21 · click to enlarge
Page 21

1.7.4 Replacing the High-limit Thermostat (cont.) 6. Locate the high-limit probe inside the frypot. Remove the high-limit probe mounting hardware. Retain mounting hardware for installation of new temperature probe

7. Carefully pull high-limit capillary tube and bulb out of the frypot from the bottom.

Locate the high-limit probe.

Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 21)
Fig. 35 · 1.7.3 Replacing the Temperature Probe; Computer-equi…

Remove high-limit capillary tube and bulb from the bottom of the frypot.

Page 22 of the Frymaster FPHD user manual — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.)
Page 22 · click to enlarge
Page 22

1.7.4 Replacing the High-limit Thermostat (cont.) 8. Mark and disconnect wires at the high-limit in the component box. 9. Remove high-limit from fryer by pulling the capillary tube and bulb through the component box opening (arrow). This may require removal of the control panel frame. 10. Reverse the above steps for high-limit installation. IMPORTANT: When installing new high-limit, ensure the capillary tube and bulb are positioned properly with the mounting hardware installed prior to tightening the compression nut. Once tightened, the capillary tube cannot be repositioned.

Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 22)
Fig. 36 · 1.7.3 Replacing the Temperature Probe; Computer-equi…

Mark and disconnect high-limit wiring (arrows). Reconnect wires to the same terminals on the replacement high-limit.

Frymaster FPHD — 1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.) diagram (page 22)
Fig. 37 · 1.7.3 Replacing the Temperature Probe; Computer-equi…

Component box opening (arrow).

Page 23 of the Frymaster FPHD user manual — FIGURE B
Page 23 · click to enlarge
Page 23

1.7.5 Replacing Rocker Switches 1. Disconnect the fryer from the electrical supply. 2. If switches are located in a control box within the fryer, remove the six screws securing the switch panel to the control box. Do not allow the switch panel to hang from the switch wiring harness or other wires. (Figure B)

Remove six screws.

Remove the screws holding the plate in place, then depress the clips on each end to remove the switch.

FIGURE B

Page 24 of the Frymaster FPHD user manual — FIGURE B
Page 24 · click to enlarge
Page 24

1.7.5 Replacing Rocker Switches (cont.) 3. Depress the retaining clips (see illustration below) and push the switch out of the slot. If there is a switch-guard present, retain it for installation of the replacement switch.

Depress clips on each side to remove switch from control panel. 4. Remove wires one at a time from the switch being removed and connect to the replacement switch until all wires are transferred. 5. Reverse the above steps for reassembly. 1.7.6 Replacing the Gas Valve

1. Disconnect fryer from electrical and gas supplies. 2. Disconnect the wires from the gas valve terminal block, marking each wire to facilitate reconnections. For 120VAC gas valves, disconnect the black wire from the high-limit, then remove the bobtail connecting the white wire. 3. Remove the high-limit thermostat wire from the gas valve pilot coil (all but 120 VAC valves). 4. Remove the pilot gas line fitting from the gas valve. 5. Remove the pipe union collars to the left and right of the gas valve and remove the valve. 6. Remove the pipefitting from the old gas valve and install on the replacement valve, using Loctite PST567 or equivalent pipe thread sealant on threads. Do not apply sealant to the first two pipe threads. Doing so will clog and damage the gas valve. 7. Reverse steps 1-5 to install the replacement gas valve.

Page 25 of the Frymaster FPHD user manual — FIGURE B
Page 25 · click to enlarge
Page 25

1.7.7 Replacing the Pilot Assembly 1. Remove the pilot tubing from the bottom of the pilot assembly. 2. If the pilot is an electronic ignition pilot, disconnect the ignition cable and the sense wire. 3. Remove the pilot mounting screw(s) from the pilot mounting bracket and remove the pilot. 4. Reverse the procedure to replace the pilot assembly.

filled with hot cooking oil or to transfer hot cooking oil from one container to

another. 2. Turn gas valve off, then turn gas off at supply valve or meter. Disconnect supply line from gas manifold at rear of fryer. NOTE: If restraints are installed on the fryer, disconnect restraints prior to disconnecting the gas supply line. 3. Unplug fryer from electrical supply source. 4. Remove fryer door for easier access to the temperature probe. First, remove top hinge from bracket. Then, lift door off bottom hinge pin. 5. Remove the basket hanger from the flue cap by lifting up and off of fryer. Some units may have a built-in flue deflector on the basket hanger. Units with basket lifts will require the removal of the lift arms prior to removing the basket hanger.

Frymaster FPHD — FIGURE B diagram (page 25)
Fig. 38

Removing the basket hanger from the flue cap.

Page 26 of the Frymaster FPHD user manual — FIGURE B
Page 26 · click to enlarge
Page 26

1.7.8 Replacing the Frypot (cont.) 6. Remove the top cap. It is held in place by one screw on each side of the fryer. If the fryer has a controller on the front, the top cap may also be held in place by two screws on the front of each pot. FPHD65 units may have two screws on each end of the top cap. 7. Remove the joiner strips on either side of the frypot. Be careful not to bend the joiner strip during removal.

Frymaster FPHD — FIGURE B diagram (page 26)
Fig. 39
Frymaster FPHD — FIGURE B diagram (page 26)
Fig. 40

Removing the joiner strip.

8. Remove back panels of the fryer. There may be both upper and lower panels and several screws secure them. Screw location and orientation will vary according to fryer model. 9. Remove screw securing brace (and back panel) to the flue cap. Support the brace with hand while removing screw to prevent brace from falling away. Remove brace and set aside for reassembly.
Frymaster FPHD — FIGURE B diagram (page 26)
Fig. 41

Typical screw locations on the back panel (may vary by model).

Frymaster FPHD — FIGURE B diagram (page 26)
Fig. 42

Removing brace holding back panel to flue cap.

Page 27 of the Frymaster FPHD user manual — FIGURE B
Page 27 · click to enlarge
Page 27

1.7.8 Replacing the Frypot (cont.) 10. Remove screws securing flue cap to frypot (access from above; a nut-driver with an extension or long screwdriver is required). Use care not to drop the screws into the flues. If this happens, the screws can be retrieved when the flue is removed (Step 16). Use a screwdriver or similar tool to free flue cap from frypots. Remove flue cap by lifting up and off of fryer.

Remove the screws (arrows) securing the flue cap to the frypot on the short edge. There will be two screws on each end of the flue. (view from above, looking down into flue) 11. Remove gas manifold pipe for access to gas manifold shield by disconnecting at the unions. Ensure gas supply is shut off and supply line is disconnected prior to removing. Set gas manifold aside. Remove screws securing gas manifold shield. Remove shield to access oil- return plumbing components connected to the frypots.

Remove the screws (arrow) securing the flue cap to the frypot on the long edge. There will be two or three screws depending on configuration. (view from above, looking down into flue)

Frymaster FPHD — FIGURE B diagram (page 27)
Fig. 43

Removing gas manifold shield.

Page 28 of the Frymaster FPHD user manual — FIGURE B
Page 28 · click to enlarge
Page 28

1.7.8 Replacing the Frypot (cont.) 12. Remove screws securing flue to frypot (access from above; a nut-driver with an extension or long screwdriver is required). Retrieve any screws dropped into the flue during removal of the flue cap and frypot bracket. 13. Remove the clevis clip and oil return handle rod from the oil return valve at the rear of the fryer. Slip Section A of the clevis clip off of the oil return handle by pulling up on the rings. Slide the oil return handle out of the bracket and Section B of the clevis clip. Repeat for the drain flush handle (if applicable). 14. Loosen the two screws on the front of the oil return handle bracket at the front of the fryer. Remove the bracket and handle and set aside for reassembly. Repeat for the drain flush handle (if applicable).

Frymaster FPHD — FIGURE B diagram (page 28)
Fig. 44

Removing bolts (arrows) securing flue to frypot.

Disconnect oil-return handle from clevis clip and valve.

Oil-return handle bracket and screws.

Page 29 of the Frymaster FPHD user manual — FIGURE B
Page 29 · click to enlarge
Page 29

1.7.8 Replacing the Frypot (cont.) 15. Remove the drain manifold. Only the drain tubes directly blocking the frypot being replaced require removal. - Remove the nuts holding the drain valve strap onto the drain tube stud. - Disconnect the Teflon tube at the back of the center dump tube piece and any other components attached to the tubes, including drain flush flexlines.

Drain manifold parts.

- Loosen the nut on each clamp holding the rubber boots and drain sections together. - Carefully remove the tubes by pulling down at an angle, straight out of the drain valves, and working them gently out of the rubber boots. Set aside for reassembly. 16. Remove the nipple attaching the oil return line to the bottom of the frypot at the rear of the fryer using a wrench. This may require removal of other pieces of the oil return manifold, as needed. 17. Remove the burner shield by loosening the screw on each end. 18. Remove the burner rail by loosening the screw on each end. The burner rail secures the burners in the burner manifold. Be careful to ensure that the burners do not fall out of the gas manifold, as they might be damaged and dented.

Oil-return nipple, burner shield, and burner rail.

Frymaster FPHD — FIGURE B diagram (page 29)
Fig. 45
14. Remove the burners to gain access to the temperature probe and to ease frypot removal. Lean each burner slightly away from the frypot to clear the burner seal (metal box attached to frypot). Then, pull the burner up and off of the orifice. The burners should be easy to remove and do not require force.
Frymaster FPHD — FIGURE B diagram (page 29)
Fig. 46
Frymaster FPHD — FIGURE B diagram (page 29)
Fig. 47
Frymaster FPHD — FIGURE B diagram (page 29)
Fig. 48

Removing drain valve handle and burners from fryer.

Show 5 more labels / short text on this page
Valve · Nut · Boot · Clamp Stud & · Strap
Page 30 of the Frymaster FPHD user manual — FIGURE B
Page 30 · click to enlarge
Page 30

1.7.8 Replacing the Frypot (cont.) 19. If the fryer is equipped with drain-valve microswitches, mark the wires and microswitch terminals, then disconnect wires from the switch. Secure the wires to prevent damage when frypot is removed. 20. Remove the drain valve handle by loosening the drain valve nut and removing attached hardware. Depending on placement and configuration, the valve may be turned in a different direction than pictured. 21. Remove the pilot assembly from the frypot. - If trailing pilot, disconnect the pilot supply

Frymaster FPHD — FIGURE B diagram (page 30)
Fig. 49

Left: Microswitch wires marked for removal (ensure microswitch terminals are marked the same as the wires removed). Right: Microswitch mounted to drain valve.

Remove the drain valve nut and attached

hardware.

line from the trailing pilot valve on the burner manifold. Remove the mounting screw(s) to detach the pilot assembly from the pilot bracket.

Remove the pilot assembly from the pilot bracket on the frypot.

Page 31 of the Frymaster FPHD user manual — FIGURE B
Page 31 · click to enlarge
Page 31

1.7.8 Replacing the Frypot (cont.) 22. Remove the temperature probe from frypot. (See Section 1.7.3, Replacing the Temperature Probe: Computer–equipped Fryers, for specific instructions.) 23. Remove the high-limit from the frypot. 24. Remove bolts from brackets securing burner manifold to frypot. Leave the manifold in place. 25. Using a sharp knife or box-cutter, cut the silicon seal around the frypot. Use care not to scratch stainless steel surfaces.

Frymaster FPHD — FIGURE B diagram (page 31)
Fig. 50

Removing bolts (arrows) from burner manifold support brackets (both sides). Leave the burner manifold in place after removing bolts.

Frymaster FPHD — FIGURE B diagram (page 31)
Fig. 51

Cutting frypot seal prior to frypot removal.

Page 32 of the Frymaster FPHD user manual — 1.7.8 Replacing the Frypot (cont.)
Page 32 · click to enlarge
Page 32

1.7.8 Replacing the Frypot (cont.)

26. Ensure wires and tubes will not be caught on the frypot when it is removed. 27. Remove frypot from fryer by lifting up and out.
Frymaster FPHD — 1.7.8 Replacing the Frypot (cont.) diagram (page 32)
Fig. 52 · 1.7.8 Replacing the Frypot (cont.)
28. Position the frypot upside down on a suitable work surface.

Lifting frypot from fryer.

29. Record position of the valve stem in relation to the frypot prior to removing the drain valve. If equipped, remove microswitches and mounting hardware from valve prior to removal. Using a suitable wrench, remove the drain valve from the frypot. Use Loctite PST567 sealant when installing drain valve on replacement frypot. 30. Remove all other hardware and accessories from the frypot.
Frymaster FPHD — 1.7.8 Replacing the Frypot (cont.) diagram (page 32)
Fig. 53 · 1.7.8 Replacing the Frypot (cont.)

Removing drain valve from frypot.

31. Reverse the above steps to install the replacement frypot. 32. Add a bead of silicon around the edges of the new frypot, sealing the seam where the frypot and the cabinet meet. Only do this when the frypot is completely installed.
Page 33 of the Frymaster FPHD user manual — 1.7.8 Replacing the Frypot (cont.)
Page 33 · click to enlarge
Page 33

1.8 Troubleshooting and Problem Isolation Because it is not feasible to include every issue that might occur, this section is intended to provide technicians with a general knowledge of the broad problem categories associated with this equipment and the probable causes of each. With this knowledge, the technician should be able to isolate and correct any problem encountered. You are likely to encounter problems in these broad categories:

1. ignition failure, 2. improper burner function, 3. improper temperature control, 4. improper computer function, 5. improper filtration function, 6. frypot leakage, and 7. basket lift malfunction. The probable causes of each category are discussed in the following sections. Troubleshooting guides are included in Section 1.9 to assist in identifying some of the more common problems. 1.8.1 Ignition Failure Ignition failure occurs when the ignition module fails to sense a flame within the 60-second time delay period and locks out. Turn the fryer off, locate and fix the problem, then turn fryer back on to clear the module lock. There are three primary reasons for ignition failure, listed in order of probability: 1. The gas and electrical power supplies, 2. The electronic circuits, or 3. The gas valve.

The Gas and Electrical Power Supplies The main indicators that the gas or electrical power supply is the cause of ignition failure are as follows: an entire battery of fryers fails to light, and/or there are no indicator lights illuminated on the fryer experiencing ignition failure. Verify that the quick disconnect hose is properly connected, the fryer is plugged in, the main gas supply valve is open, and the circuit breaker for the fryer electrical supply is not tripped.

Page 34 of the Frymaster FPHD user manual — 1.7.8 Replacing the Frypot (cont.)
Page 34 · click to enlarge
Page 34

1.8.1 Ignition Failure (cont.) The Electronic Circuits If gas and electrical power are supplied to the fryer, the next most likely cause of ignition failure is a problem in the 24 VAC circuit of fryers equipped with electronic ignition systems, or in the pilot system for those without electronic ignition. If the fryer is equipped with a SUFF/UFF filtration system, verify that the drain valve is fully closed. (The valve is equipped with a microswitch that must be closed for power to reach the gas valve. The valve handle can appear to be closed when the microswitch is open.) If the valve is fully closed, or the fryer does not have a filtration system, refer to the troubleshooting guides in this chapter.

The Gas Valve If the problem is not in the 24 VAC circuit or pilot system, it is most likely in the gas valve. Before replacing the gas valve, refer to the troubleshooting guides in this chapter. 1.8.2 Improper Burner Function In these instances, the burner ignites but exhibits abnormal characteristics, such as popping, incomplete lighting of the burner, fluctuating flame intensity, and flames “rolling” out of the fryer. Popping indicates delayed ignition. In most cases, the main gas valve is opening, but the burner is not immediately lighting. When ignition does take place, excess gas ignites rapidly rather than smoothly. The primary causes of popping are: 1. low or fluctuating gas pressure, 2. misdirected or weak pilot flame, 3. clogged burner orifices, 4. clogged burner flame-transfer holes 5. clogged burners, 6. inadequate make-up air, 7. heat damage to the controller or ignition module, 8. an out-of-adjustment igniter or broken ignition wire, 9. a defective ignition module, 10. missing or misaligned burners, 11. clogged vent tube (causing incorrect gas pressure), or 12. make-up air is blowing down the flue.

Page 35 of the Frymaster FPHD user manual — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER
Page 35 · click to enlarge
Page 35

1.8.2 Improper Burner Function (cont.) If popping occurs only during peak operating hours, the problem may be incorrect or fluctuating gas pressure. Verify that the incoming gas pressure (pressure to the gas valve) is in accordance with the appropriate requirements listed in the Installation and Operation manual that came with the fryer, and that the pressure remains constant throughout all hours of usage. Refer to Adjusting Burner Manifold Pressure in Section 1.4 if burner manifold pressure is suspected of being incorrect. If popping is consistent during all hours of operation, verify that the pilot is properly positioned above the burner orifice and that the pilot pressure is correct. Correct pilot pressure is indicated by a flame 1 to 1½" long. Also verify that igniter is properly adjusted (electrode tip 1/8" from pilot hood corner). Refer to Section 1.5 for pilot adjustment procedure. Clogged burners, burner orifices, and burner flame transfer holes are also likely causes of delayed ignition. Clogged burners are indicated by uneven flame or partial flame on the burner face. Clogged orifices are indicated by no flame. Clogged burner flame transfer holes prevent the outermost burners from lighting immediately with the middle burners (four- and five-tube frypots). Another cause of popping is an insufficient air supply or drafts that are blowing the pilot flame away from the burner. Check for "negative pressure" conditions in the kitchen area. If air is flowing into the kitchen area, this indicates that more air is being exhausted than is being replenished and the burners may be starved for air. If the fryer’s gas and air supplies are okay, the problem most likely is with one of the electrical components. Examine the ignition module for signs of melting, distortion, or discoloration due to excessive heat build-up in the fryer. Also, examine the controller for the same conditions. This condition usually indicates improper flue performance. A melted or distorted ignition module is automatically suspect and should be replaced, but unless the condition causing excessive heat in the fryer is corrected, the problem is likely to recur. Next, ensure the ignition wire is tightly connected at both ends and examine it for obvious signs of damage. Again, if damage is due to excessive heat in the fryer, that problem must also be corrected.

Check for proper operation by disconnecting the wire from the igniter, inserting the tip of a screwdriver into the terminal, and holding it near the frame of the fryer as the power switch is placed in the "ON" position. A strong, blue spark should be generated for at least 60 seconds.

DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER

AND NOT THE BLADE. THE SPARKING CHARGE IS APPROXIMATELY 25,000

VOLTS. Ensure the gap setting of the igniter is correct (electrode tip 1/8" from pilot hood corner).

Page 36 of the Frymaster FPHD user manual — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER
Page 36 · click to enlarge
Page 36

1.8.2 Improper Burner Function (cont.) Burners lighting on the left side only may be caused by a trailing pilot problem (four- and five-tube frypots) or improper burner manifold pressure. Fluctuating flame intensity is normally caused by either improper or fluctuating incoming gas pressure, but may also be the result of variations in the kitchen atmosphere. Verify incoming gas pressure in the same way as for "popping,” discussed in the preceding paragraphs. Variations in the kitchen atmosphere are usually caused by air conditioning and/or ventilation systems starting and stopping during the day. As air conditioning/ventilation systems start and stop, the pressure in the kitchen may change from positive or neutral to negative, or vice versa. Changes in airflow patterns may affect flame intensity. Flames "rolling" out of the fryer are usually an indication of negative pressure in the kitchen and make up air blowing down the flue. Air is being sucked out of the fryer enclosure and the flames are literally following the air. If negative pressure is not the cause, check for high burner-manifold gas pressure in accordance with the procedures in Section 1.4. An obstructed flue, which prevents the fryer from properly exhausting, may also be the cause. Excessively noisy burners may indicate that the burner gas pressure is too low, the tube diffusers are defective or burned out, or it may simply be that the gas valve vent-tube is blocked (if applicable). If the gas pressure is correct, the tube diffusers are intact and in good condition, and the vent-tube is unobstructed (if applicable), the gas valve regulator is probably defective. 1.8.3 Improper Temperature Control Temperature control is a function of several interrelated components, including the melt cycle. Each must operate correctly. The principal component is the temperature probe. Depending upon the specific configuration of the fryer, other components may include the interface board, the computer/controller itself, and the ignition module. Improper temperature control problems can be categorized into melt cycle problems and failure to control at setpoint. In fryers equipped with a Thermatron, the problem will be with the thermostat. Possible causes are that the thermostat is out of calibration or defective. Refer to Section 1.6 for instructions on calibrating the thermostat. In fryers equipped with computers, the problem may be with the temperature probe, the interface board, or the computer. Refer to the troubleshooting guides in this chapter.

Page 37 of the Frymaster FPHD user manual — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER
Page 37 · click to enlarge
Page 37

1.8.4 Improper Computer Function Sensitivity or "Stretch Time." Sensitivity—or stretch time—is a programmable feature that increases the cook time countdown based on variations in the oil temperature from the setpoint (e.g., when cold product is dropped into the oil, causing the oil temperature to drop).

The sensitivity for each product button has 10 settings (0 through 9). A "0" sensitivity setting will disable the feature (no change in cooking time), while a nine will provide the highest sensitivity or the most change. The correct sensitivity for any product is based on the product type, its density, the setpoint temperature, and the customer’s own requirements. Common Computer Complaints. Most problems concerning computers have to do with programming them. There are four common complaints. The complaints, their causes, and corrective actions are as follows: 1. Fryer constantly displays "

". CauseSetpoint incorrect or missing. Corrective Action: Press

1 6 5 0, enter the correct setpoint using keypad, then press

to lock in the setpoint. 2. Temperature is displayed in Celsius.

Cause: Computer is programmed to display in Celsius.

Corrective ActionPress

1 6 5 8. 3. Temperature is constantly displayed.

Cause: Computer is programmed for constant temperature display.

Corrective ActionPress

1 6 5 L. 4. Computer times down too slowly or too quickly. Cause: Computer is compensating for oil temperature via the sensitivity setting. Corrective Action: Reprogram sensitivity setting for each product in accordance with programming instructions in the Compu-Fry Operation and Programming manual, P/N 819- 5865.

and then this

Page 38 of the Frymaster FPHD user manual — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER
Page 38 · click to enlarge
Page 38
  • 1.8.5 Improper Filtration Function The majority of filtration problems arise from operator error. One of the most common errors is placing the filter paper on the bottom of the filter pan rather than over the filter screen. Anytime the pump is running, but no oil is being filtered, check the installation and size of the filter paper. Verify that the O-rings on the slip-connection are in good condition. Missing or worn O-rings allow the pump to suck air, decreasing its efficiency. If the pump motor overheats, the thermal overload will trip and the motor will not start until it is reset. If the pump motor does not start, press the red reset switch located on the rear of the motor. Also, reset the filter circuit breaker located under the fryer control panel. If the pump then starts, something caused the motor to overheat. The pump most likely overheated for one of the following reasons:
  • Shortening was solidified in the pan or filter lines.
  • Multiple frypots were filtered one-after-another. Allow the pump to cool for 30 minutes before using again.
  • The operator attempted to filter unheated oil. Cold oil is thick and will cause the pump motor to work harder and overheat. If the motor runs, but the pump does not, the pump is blocked. Incorrectly sized or installed paper allows food particles and sediment to pass through the filter pan and into the pump. When sediment enters the pump, the gears bind and cause the motor to overheat, tripping the thermal overload. Solidified shortening in the pump will produce the same result. A pump seized by debris or hard shortening must be disassembled, cleaned, and reassembled in the following manner: 1. Disconnect power to the filter system. 2. Remove the front cover of the pump to access the gears inside, if the pump is accessible while still inside the cabinet. If the front cover is not accessible, the pump must be removed from the pump motor (disconnect input/output plumbing from the pump prior to removing it). Remove three setscrews to disengage the pump from the motor.
3. Prior to reassembly, the inside housing must be clean and free of any sediment or debris. If not, the gears will bind again after reassembly.
Frymaster FPHD — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER diagram (page 38)
Fig. 54
Frymaster FPHD — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER diagram (page 38)
Fig. 55

Remove these bolts to

Remove debris or hardened

remove pump cover.

shortening to free gears.

Page 39 of the Frymaster FPHD user manual — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER
Page 39 · click to enlarge
Page 39

1.8.5 Improper Filtration Function (cont.) Incorrectly sized or installed paper will allow food particles and sediment to pass through and clog the suction tube on the bottom of the filter carriage. Particles large enough to block the suction tube may indicate that the crumb tray is not being used. Pan blockage can also occur if shortening is left in the pan and allowed to solidify. Heater strips (if equipped) on the oil return plumbing are designed to prevent solidification of shortening left in the plumbing. Heater strips will not melt or prevent solidification of shortening in the pan. Remove blockage by forcing it out with an auger or drain snake. DO NOT use compressed air or other pressurized gases to force out the blockage. The SUFF/UFF filtration systems use microswitches attached to handles for each vat. They are wired in parallel and provide the 24 VAC required to activate the pump relay coil when the handles are moved to the ON position. The activated pump relay coil pulls the pump motor switch in, supplying power to the pump motor. Filter systems equipped with oil-return heater tape are wired into the 120 VAC source, and remain energized as long as the unit is plugged in and power remains constant. Heater tape should receive constant power all day and all night; it should not be connected to a power supply that is turned off at night. 1.8.6 Frypot Leakage Frypot leaks are almost always due to improperly sealed high-limit, thermostats/temperature probe and drain fittings. When installed or replaced, each of these components must be sealed with Loctite PST567 sealant or equivalent to prevent leakage. In very rare cases, a leak may develop along one of the welded edges of the frypot, or where the tube is welded to the frypot. When this occurs, the frypot must be replaced. If the sides or ends of the frypot are coated with oil, the most likely cause is spillage over the top of the frypot rather than leakage.

Frymaster FPHD — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER diagram (page 39)
Fig. 56

Frypot locations (indicated by arrows) where potential leaks could occur.

Page 40 of the Frymaster FPHD user manual — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER
Page 40 · click to enlarge
Page 40
  • 1.8.7 Improper Basket Lift Function Bell-Crank Basket Lifts Most High Efficiency Decathlon Series gas fryers are equipped with a bell-crank style basket lift. A cam and a bell crank are connected to the basket lift arm by a flat metal link. The cam is attached to a drive motor. The motor rotates the cam, raising or lowering the lift arm linked to the bell crank. A roller-activated microswitch is used to limit travel. When the roller in the microswitch is in contact with the cam, the motor is energized. As the cam rotates, the roller loses contact with the cam and the motor power circuit is broken, de-energizing the motor. Timing circuitry in the controller initiates and stops basket lift operation. When the product button is pressed, the timing circuitry activates a coil in the basket lift relay to supply power to the motor. The microswitch stops the motor at the lift’s lower travel limit and the switch contacts are reversed. At the end of the programmed cooking time, the timing circuit activates the coil once more and the lift rises until the microswitch again loses contact with the cam, opening the motor power circuit and stopping the motor. Problems with the bell-crank basket lift system can be grouped into two categories:
  • binds and jams or
  • motor and gear wear. Binds and jams. Noisy, jerky, or erratic lift movement is usually due to lack of lubrication. Apply a light coat of Lubriplate or similar lightweight white grease to the connection points to correct the problem. Motor Problems. If power is reaching the motor but the motor fails to run, the motor is burned out and must be replaced.
Frymaster FPHD — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER diagram (page 40)
Fig. 57

Back view of bell-crank basket lift.

Frymaster FPHD — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER diagram (page 40)
Fig. 58

Bell-crank basket-lift arms.

Page 41 of the Frymaster FPHD user manual — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER
Page 41 · click to enlarge
Page 41

1.9 Troubleshooting Guides The following troubleshooting guides are intended to assist service technicians in quickly isolating the probable causes of equipment malfunctions by following a logical, step-by-step process.

Frymaster FPHD — DANGER MAKE SURE YOU ARE HOLDING THE INSULATED HANDLE OF THE SCREWDRIVER diagram (page 41)
Fig. 59

PROBLEM PROBABLE CAUSES CORRECTIVE ACTION Burner will not ignite. Light in ON/OFF switch

A. ON/OFF switch is off. A. Turn ON/OFF switch on.

ON/OFF switch is on, but the switch light is not

A. No voltage at switch. A. Ensure line voltage is present at the

but continuity of the switch in ON position is not "0.”

(oil temperature is at least 15°F below electronic thermostat setting).

D. Gas valve is suspect. D. Go to "No burner flame" section.

Page 42 of the Frymaster FPHD user manual — 1.9 Troubleshooting Guides (cont.)
Page 42 · click to enlarge
Page 42

1.9 Troubleshooting Guides (cont.)

C. Gas valve is known to be good, but

D. Inspect electronic sensor (while still in

there is not 24 VAC (120VAC on systems so equipped) at the gas valve terminals.

frypot) for damage. Replace if bent, dented, or cracked. Inspect leads for fraying, burning, breaks, and/or kinks. If found, remove and replace thermostat(s). Remove leads from terminal block, allow oil to cool 15°F (8°C) below thermostat setting, and check continuity. If continuity is not "0,” then thermostat has failed. Replace thermostat(s).

No burner flame.

E. Continuity from terminal block to gas

E. Inspect wiring for breaks or shorts and

valve electronic/operating thermostat wire is not "0."

repair if necessary.

A. Incoming gas supply pressures are not

A. Inspect gas supply to fryer. Repair

and/or replace faulty components (defective supply shut-off valves, incorrect piping size, etc.) Fluctuating or erratic lighting of burner flame. B. Air in gas supply lines (new

within range [Natural- 6-14" W.C. (1.49-3.49 kPa); Propane- 11-14" W.C. (2.74-3.49 kPa)]

B. Allow unit to cycle on and off for

installation).

approximately 30 minutes to force air from gas manifold and lines.

Electronic/operating thermostat will not adjust

A. Electronic/operating thermostat is out

A. Calibrate electronic/operating

thermostat. Replace if calibration is not possible.

of calibration.

to correct temperature.

Page 43 of the Frymaster FPHD user manual — 1.9 Troubleshooting Guides (cont.)
Page 43 · click to enlarge
Page 43

1.10 Wiring Diagrams Note: The diagrams in this section depict wiring as of the date of manual publication. It may not reflect design changes made to the equipment after publication. Refer to the wiring diagram affixed to the unit when actually troubleshooting this equipment. High Efficiency Decathlon, Thermatron with Constant Pilot (Right/left sides are the same.)

Page 44 of the Frymaster FPHD user manual — Computer with Constant Pilot
Page 44 · click to enlarge
Page 44

Computer with Constant Pilot

Frymaster FPHD — Computer with Constant Pilot diagram (page 44)
Fig. 60 · Computer with Constant Pilot
Page 45 of the Frymaster FPHD user manual — Computer with Constant Pilot
Page 45 · click to enlarge
Page 45
Frymaster FPHD — Computer with Constant Pilot diagram (page 45)
Fig. 61 · Computer with Constant Pilot

CM4-S Wiring

Page 46 of the Frymaster FPHD user manual — Dean Oil Return Wiring
Page 46 · click to enlarge
Page 46

Dean Oil Return Wiring

Page 47 of the Frymaster FPHD user manual — Dean Oil Return Wiring, with Solenoid
Page 47 · click to enlarge
Page 47

Dean Oil Return Wiring, with Solenoid

Page 48 of the Frymaster FPHD user manual — 1.11 Probe Resistance Charts
Page 48 · click to enlarge
Page 48

1.11 Probe Resistance Charts

Frymaster FPHD — 1.11 Probe Resistance Charts diagram (page 48)
Fig. 62 · 1.11 Probe Resistance Charts
Frymaster FPHD — 1.11 Probe Resistance Charts diagram (page 48)
Fig. 63 · 1.11 Probe Resistance Charts

° Celsius ° Fahrenheit Ohms (±3%) 21 70 108130 27 80 84606 32 90 66721 38 100 53020 43 110 42452 49 120 34206 54 130 27735 60 140 22641 66 150 18588 71 160 15349 77 170 12741 82 180 10635 88 190 8925 93 200 7527 99 210 6391 104 220 5470 110 230 4705 116 240 4030 121 250 3441 127 260 2967 132 270 2583 138 280 2255 143 290 1977 149 300 1729 154 310 1496 160 320 1320 166 330 1170 171 340 1051 177 350 942 182 360 840 188 370 750 193 380 676 199 390 605 204 400 541

° Celsius ° Fahrenheit Ohms (±3%) 21 70 1080 27 80 1101 32 90 1122 38 100 1143 43 110 1164 49 120 1185 54 130 1206 60 140 1226 66 150 1247 71 160 1268 77 170 1289 82 180 1309 88 190 1330 93 200 1350 99 210 1371 104 220 1391 110 230 1412 116 240 1432 121 250 1453 127 260 1473 132 270 1493 138 280 1514 143 290 1534 149 300 1554 154 310 1574 160 320 1594 166 330 1614 171 340 1634 177 350 1654 182 360 1674 188 370 1694 193 380 1714 199 390 1734 204 400 1754

Page 49 of the Frymaster FPHD user manual — 2.1 High Efficiency Decathlon (HD) Primary Components
Page 49 · click to enlarge
Page 49

2.1 High Efficiency Decathlon (HD) Primary Components

Frymaster FPHD — 2.1 High Efficiency Decathlon (HD) Primary Components diagram (page 49)
Fig. 64 · 2.1 High Efficiency Decathlon (HD) Primary Component…
Page 50 of the Frymaster FPHD user manual — 2.1 High Efficiency Decathlon (HD) Primary Components
Page 50 · click to enlarge
Page 50

Parts are labeled to indicate the appropriate fryer model (“HD”, “SCFHD”, or “FPHD65”). If a part is not labeled, it can be used on any of these models. Each section is labeled by size (e.g., D50) and parts are not interchangeable between different sized fryers. Some SCFHD fryers use Common Cabinet configurations and these parts are labeled "SCFHD C/C;" otherwise, use "SCFHD"-labeled parts when an "SCFHD C/C" part is not indicated. To determine if the SCFHD fryer utilizes Common Cabinet configuration, examine the door handles. A curved flat metal handle (Item 25, Section 2.1.2) indicates Common Cabinet configuration; a wireform handle (Item 24, Section 2.1.2) indicates a unit that does not have a Common Cabinet configuration. If you have any questions, call the Frymaster and Dean 24-Hour Service Hotline, 1-800-551-8633. 2.1.1 Decathlon HD50 Primary Components (includes SCFHD units)

ITEM PART # COMPONENT 1 823-6138 Frypot - S/S (SCFHD; with insulation: 106-6157) * 823-5743 Frypot - S/S (Single HD without filtration; with insulation: 106-6614) 2 810-2130 Manifold, Gas 3 ►►► See Orifices, Section 2.2 4 810-2032 Pilot Burner, Natural/G20/25 Gas * 810-2155 Pilot Burner, LP/G31 Gas * 106-1839SP Pilot Assembly, Natural Gas Electronic Ignition with Computer * 106-1238SP Pilot Assembly, Natural Gas Electronic Ignition without Computer * 810-0705 Tube, 1⁄4" x 20" Pilot Gas Supply (one-piece gasline) * 810-0703 Tube, 1⁄4" x 171⁄2" Pilot Gas Supply (one-piece gasline) 5 220-1231 Bracket, Manifold Support (right or left) 6 230-1342 Diffuser Assembly 7 ►►► See Drain Manifold Components, Section 2.5 8 810-2785 Burner, High Efficiency 9 200-9063 Burner Heat Shield 10 807-3552 Gas Valve, Natural Gas Electronic Ignition, 24 VAC * 807-3628 Gas Valve, LP Gas Electronic Ignition, 24 VAC * 807-3294 Gas Valve, Natural Gas, Constant Pilot, 24 VAC * 807-3295 Gas Valve, LP Gas, Constant Pilot, 24 VAC * 807-2091 Gas Valve, G20/G25 Gas, 24 VAC (CE only) * 807-2127 Gas Valve, G31 Gas, 24 VAC (CE only) * 810-0691 Vent Tube 11 200-1148 Channel, Front and Rear (Single, SCFHD50 C/C) * 823-5823 Channel, Front Base (2-battery, SCFHD50 C/C) * 220-0890 Channel, Front Base (3-battery, SCFHD50 C/C) * 220-1335 Channel, Rear Base (2-battery, SCFHD50 C/C) * 220-1372 Channel, Rear Base (3-battery, SCFHD50 C/C) * 220-2422 Channel, Rear Base (5-battery/4-battery with matching cabinet, SCFHD50 C/C) * 106-5901 Base Assembly (2-battery, SCFHD50 C/C) * 106-7622 Base Assembly (5-battery/4-battery with matching cabinet, SCFHD50 C/C) 12 823-5346 Hinge, Lower Left * 823-5347 Hinge, Lower Right 13 823-5348 Hinge, Upper Left * 823-5349 Hinge, Upper Right * 823-4894 Hinge, Lower Left (SCFHD50 C/C) * 823-4895 Hinge, Lower Right (SCFHD50 C/C) * 823-5136 Hinge, Upper Left (SCFHD50 C/C) * 823-5137 Hinge, Upper Right (SCFHD50 C/C) 14 211-2787 Side Panel, Left Side 15 212-2787SP Side Panel, Right Side * Not illustrated.

Page 51 of the Frymaster FPHD user manual — 2.1 High Efficiency Decathlon (HD) Primary Components
Page 51 · click to enlarge
Page 51

2.1.1 Decathlon HD50 Primary Components (includes SCFHD units) (cont.) ITEM PART # COMPONENT * 231-2060 Side Panel, Left Side (SCFHD50 C/C) * 232-2060 Side Panel, Right Side (SCFHD50 C/C) 16 200-1674 Back Panel, Lower * 200-3183 Back Panel (2-battery) * 200-3567 Back Panel (3-battery) 17 823-5303 Wireway, Control Panel 18 ►►► See Control Panel Options, Joiner Strips, and Accessories, Section 2.3 19 824-1103 Top Cap, Single * 824-0937 Top Cap, Double * 106-5955 Top Cap, Double (SCFHD50 C/C) * 824-0983 Top Cap, Triple 20 106-3720 Flue Box Assembly * 200-6269 Shield, Flue Heat * 200-6268 Front, Flue Box * 200-6270 Rear, Flue Box 21 823-3521 Flue Cap (Single) * 823-3634 Flue Cap (Double) * 106-6777 Flue Cap (Triple) * 200-1682 Bracket, Flue Mounting 22 106-4727SP Door Assembly, Left * 106-4728 Door Assembly, Right * 210-8946 Panel, Outer Door, Left/Right * 201-8945 Panel, Inner Door, Left 23 106-7542 Door Assembly (SCFHD50 C/C) * 230-2256 Panel, Outer Door * 220-2259 Panel, Inner Liner 24 810-0180 Handle, Door, Wireform 25 210-8077 Handle, Door, Common Cabinet * 810-1105 Magnetic Catch, Door * 803-0271 Basket, Twin * 803-0099 Basket, Full 26 803-0277 Grid Assembly, Fine Mesh 27 210-1595 Hanger, Basket, Single System, (attaches to flue) * 210-3131 Hanger, Basket, Double System (attaches to flue) 28 810-0356 Caster, Plate-mount, 5-inch without Brake 29 810-0357 Caster, Plate-mount, 5-inch with Brake * 826-1117 Caster Kit (includes 810-0356 and hardware x1) * 826-1118 Caster Kit (includes 810-0357 and hardware x1) 30 812-1226SP Drain Nipple, Extended 1¼” " Drain (Single) * 812-1717SP Drain Nipple, Extended 1½” Drain * 807-0154 Cordset, 10' Power 31 210-2804 Cover, Outlet Duct 32 810-2411 Leg, Single Bolt Mount (black) * 810-3169 Leg Package, 4 Bolt Mount (4 per set) 33 823-3248 Leg Support Assembly 34 200-8895 Burner Mounting Rail 35 220-0891 Brace, Front Horizontal, Single (SCFD C/C) * 220-0882 Brace, Front Horizontal, Double (SCFD C/C) * Not illustrated.

Page 52 of the Frymaster FPHD user manual — 2.1 High Efficiency Decathlon (HD) Primary Components
Page 52 · click to enlarge
Page 52

2.1.2 Decathlon HD60 Primary Components (includes SCFHD units) ITEM PART # COMPONENT 1 823-4692 Frypot - S/S (SCFHD) * 823-5742 Frypot - S/S (Single HD without filtration) * 106-7853 Frypot - S/S (SCFHD63) * 823-6314 Frypot - S/S (Single HD63 without filtration) 2 810-2072 Gas Manifold (weld assembly; also used on HD63 fryers) 3 ►►► See Orifices, Section 2.2 4 810-2032 Pilot Burner, Natural/G20/25 Gas * 810-2155 Pilot Burner, LP/G31 Gas * 106-1839SP Pilot Assembly, Natural Gas Electronic Ignition with Computer * 106-1238SP Pilot Assembly, Natural Gas Electronic Ignition without Computer * 810-0705 Tube, Pilot Gas Supply, 1⁄4" x 23" (one-piece gasline) * 810-0703 Tube, Pilot Gas Supply, 1⁄4" x 171⁄2" (one-piece gasline) 5 220-1231 Bracket, Manifold Support (right or left) 6 230-1431 Diffuser Assembly 7 ►►► See Drain Manifold Components, Section 2.5 8 810-2785 Burner, High Efficiency 9 200-1363 Heat Shield, Lower * 200-8053 Heat Shield, Vessel * 812-0211 Insulation, Kaowool Blanket, .5” x 7.5” x 17.5” * 230-2057 Support, Burner 10 807-3552 Gas Valve, Natural Gas, Electronic Ignition, 24 VAC (3⁄4" in, 1⁄2" out) * 807-3628 Gas Valve, LP Gas, Electronic Ignition, 24 VAC * 807-3294 Gas Valve, Natural Gas, Constant Pilot, 24 VAC * 807-3295 Gas Valve, LP Gas, Constant Pilot, 24 VAC * 807-2091 Gas Valve, G20/G25 Gas, 24 VAC (CE only) * 807-2127 Gas Valve, G31 Gas, 24 VAC (CE only) * 810-0691 Vent Tube * 823-3347 Frame, Slide Base 11 220-2187 Channel, Rear and Front * 200-3219 Channel, Base (Single and 3-battery) * 200-1198 Channel, Base (2-, 3-, and 4-battery) * 200-1463 Channel, Base (4-battery) * 200-1393 Channel, Lower Joiner * 823-5790 Channel, Base (Single, SCFHD60 C/C) * 200-8095 Channel, Front Base (SCFHD60 C/C) * 220-1339 Channel, Rear Base (3-battery, SCFHD60 C/C) * 220-1362 Channel, Rear Base (4-battery, SCFHD60 C/C) * 106-4424 Base Assembly (4-battery, SCFHD60 C/C) * 106-5622 Base Assembly (3-battery, SCFHD60 C/C) * 106-6643 Base Assembly, HD63 12 823-5346 Hinge, Lower Left * 823-5347 Hinge, Lower Right 13 823-5348 Hinge, Upper Left * 823-5349 Hinge, Upper Right * 823-4894 Hinge, Lower Left (SCFHD50 C/C) * 823-4895 Hinge, Lower Right (SCFHD50 C/C) * 823-5136 Hinge, Upper Left (SCFHD50 C/C) * 823-5137 Hinge, Upper Right (SCFHD50 C/C) * Not illustrated.

Page 53 of the Frymaster FPHD user manual — 2.1.2 Decathlon HD60 Primary Components (includes SCFHD units) (cont.)
Page 53 · click to enlarge
Page 53

2.1.2 Decathlon HD60 Primary Components (includes SCFHD units) (cont.)

ITEM PART # COMPONENT 14 211-4570 Side Panel, Left Side (unit exterior) 15 212-4570 Side Panel, Right Side (unit exterior) * 201-4775 Side Panel, Left Side with Hole (unit interior) * 202-4775 Side Panel, Right Side with Hole (unit interior) * 211-5693 Side Panel, Left Side, Single (unit exterior) * 212-5693 Side Panel, Right Side, Single (unit exterior) * 231-2311 Side Panel, Left Side (unit exterior, SCFHD60 C/C) * 232-2311 Side Panel, Right Side (unit exterior, SCFHD60 C/C) * 231-2311 Side Panel, Left Side (unit exterior, HD63) * 232-2311 Side Panel, Right Side (unit exterior, HD63) * 201-1245 Panel, Inner Left (divider located over filter unit) * 202-1245 Panel, Inner Right (divider located over filter unit) * 201-4237 Panel, Inner Left (divider located over filter unit), Church's * 202-4237 Panel, Inner Right (divider located over filter unit), Church's 16 200-1327 Back Panel, Lower (Single) * 200-1222 Back Panel, Lower (Double) * 200-4238 Back Panel, Lower (Church's Double) * 200-1213 Back Panel, Upper (Single) 17 824-1195 Wireway, Control Panel 18 ►►► See Control Panel Options, Joiner Strips, and Accessories, Section 2.3 19 Top Cap * 824-0987 x1 (Single) * 824-0937 x2 (2-battery) * 824-0992 x3 (3-battery) * 824-0960 x4 (4-battery) * 106-6080 x3 (3-battery, SCFHD60 C/C) * 106-4683 x4 (4-battery, SCFHD60 C/C) * 106-5434 x1 (Single, HD63) * 106-6080 x3 (3- and 6-battery, HD63) * 106-4683 x4 (4- and 6-battery, HD63) 20 106-4375 Flue Box Assembly (also used on HD63 fryers) * 200-8220 Front, Flue Box * 200-8221 Back, Flue Box * 200-8219 Shield, Flue Box * 200-3649 Deflector, Flue (Single, HD, non-S/S) (use screws 809-0437) * 210-6525 Deflector, Flue (Single, Chili's, S/S) (use screws 809-0437) 21 823-3635 Flue Cap (Single) * 823-3516 Flue Cap (2-battery) * 230-1850 Flue Cap (HD63) 22 106-4721 Door Assembly, Left * 200-4794 Panel, Door, Inner * 211-8935 Panel, Door, Outer * 106-4722 Door Assembly, Right * 200-4794 Panel, Door, Inner * 212-8935 Panel, Door, Outer 23 106-4309 Door Assembly (SCFHD60 C/C) * 200-8076 Panel, Door, Inner * 210-8075 Panel, Door, Outer * Not illustrated.

Page 54 of the Frymaster FPHD user manual — 2.1.2 Decathlon HD60 Primary Components (includes SCFHD units) (cont.)
Page 54 · click to enlarge
Page 54

2.1.2 Decathlon HD60 Primary Components (includes SCFHD units) (cont.)

ITEM PART # COMPONENT 24 810-0180 Handle, Door, Wireform 25 210-8077 Handle, Door, Common Cabinet * 810-1105 Magnet, Door * 803-0304 Fry Basket, Twin 26 803-0149 Grid Assembly, Mesh * 810-2235 Grid Assembly, Rack 27 210-2737SP Basket Hanger, Single, no Splash Guard * 823-4999 Basket Hanger, Chili’s Double System, 6” Splash Guard 28 810-0356 Caster, Plate-mount 5" without Brake * 810-2406 Caster, Single Stud-mount 5" without Brake 29 810-0357 Caster, Plate-mount 5" with Brake * 810-2405 Caster, Single Stud Mount 5" with Brake 30 812-1226SP Drain Nipple, Extended, 1 ¼” * 812-1717SP Drain Nipple, Extended, 1 ½” * 106-0913SP Cordset, 10’ Power 31 210-9416 Cover, Outlet Duct 32 810-2411 Leg, Single Bolt Mount (black) * 810-3169 Leg Package, 4 Bolt Mount (4 per set) 33 823-3248 Leg Support Assembly 34 200-8835 Burner Mounting Rail * 200-2308 Post, Door * 201-1182 Gusset, Side Panel Left * 202-1182 Gusset, Side Panel Right * 200-1611 Base, Cabinet * 210-9416 Duct, Door Access * 200-2713 Plate, Suction Manifold * 210-1180 Insert, Suction Manifold 35 220-0891 Brace, Front Horizontal, Single (SCFD C/C) * 220-0882 Brace, Front Horizontal, Double (SCFD C/C) * Not illustrated. 2.1.3 Decathlon FPHD65 Primary Components

ITEM PART # COMPONENT 1 823-5243 Frypot - S/S 2 810-2072 Gas Manifold (weld assembly) 3 ►►► See Orifices, Section 2.2 4 810-2032 Pilot Burner, Natural/G20/25 Gas (primary and trailing, 120V) * 810-2155 Pilot Burner, LP/G31 Gas (primary and trailing) * 812-1674 Pilot Burner, Mod. Natural Gas (electronic ignition) * 810-0705 Tube, Pilot Gas Supply, 1⁄4" x 23" (one-piece gasline) * 810-0703 Tube, Pilot Gas Supply, 1⁄4" x 171⁄2" (one-piece gasline) 5 220-1231 Bracket, Manifold Support (right or left) 6 230-1431 Diffuser Assembly 7 ►►► See Drain Manifold Components, Section 2.5 8 810-2785 Burner, High Efficiency 9 200-8748 Heat Shield, Lower * 200-8053 Heat Shield, Vessel * 230-2057 Support, Burner * Not illustrated.

Page 55 of the Frymaster FPHD user manual — 2.1.3 Decathlon FPHD65 Primary Components (cont.)
Page 55 · click to enlarge
Page 55

2.1.3 Decathlon FPHD65 Primary Components (cont.)

ITEM PART # COMPONENT 10 807-3552 Gas Valve, Natural Gas, Electronic Ignition, 24 VAC * 807-3628 Gas Valve, LP Gas, Electronic Ignition, 24 VAC * 807-3294 Gas Valve, Natural Gas, Constant Pilot, 24 VAC * 807-3295 Gas Valve, LP Gas, Constant Pilot, 24 VAC * 810-2156 Gas Valve, Natural Gas, 120 VAC * 810-2323 Gas Valve, LP Gas, 120 VAC * 807-2091 Gas Valve, G20/G25 Gas, 24 VAC (CE only) * 807-2127 Gas Valve, G31 Gas, 24 VAC (CE only) * 810-0691 Vent Tube * 823-3347 Frame, Slide Base 11 Channel, Base * 106-7441 265 * 106-7357 465 * 106-6851 565, 665 12 823-4894 Hinge, Lower Left * 823-4895 Hinge, Lower Right 13 823-5136 Hinge, Upper Left * 823-5137 Hinge, Upper Right 14 211-8078 Side Panel, Left Side (unit exterior) 15 212-8078 Side Panel, Right Side (unit exterior) * 221-0012 Side Panel, Left Side with Hole (unit exterior) * 222-0012 Side Panel, Right Side with Hole (unit exterior) * 201-4237 Panel, Inner Left (divider located over filter unit) * 202-4237 Panel, Inner Right (divider located over filter unit) 16 Cabinet Upper Back * 220-2474 x1 (Single) * 220-2353 x2 (2-, 4-, 5-, and 6-battery) * 220-0668 x3 (5-battery) * Cabinet Lower Back * 220-2483 x1 (Single) * 220-2354 x2 (2-, 4-, 5-, and 6-battery) * 220-0667 x3 (5-battery) 17 824-1195 Wireway, Control Panel 18 ►►► See Control Panel Options, Joiner Strips, and Accessories, Section 2.3 19 Top Cap * 824-1781 x1 (for single) * 823-6010 x2 (for 2-battery) * 823-6011 x4 (for 4-battery) * 823-6090 x3 (for 5-battery) * 823-5975 x2 (for 5- and 6-battery) * 823-5976 x4 (for 6-battery) * 824-1656 x3, with work shelf * 230-2472 x1, HD Marine 20 106-4375 Flue Box Assembly * 200-8220 Front, Flue Box * 200-8221 Back, Flue Box * 200-8219 Shield, Flue Box * 200-3649 Deflector, Flue (Single, HD, non-S/S) (use screws 809-0437) * 210-6525 Deflector, Flue (Single, Chili's, S/S) (use screws 809-0437) * Not illustrated.

Page 56 of the Frymaster FPHD user manual — 2.1.3 Decathlon FPHD65 Primary Components (cont.)
Page 56 · click to enlarge
Page 56

2.1.3 Decathlon FPHD65 Primary Components (cont.)

ITEM PART # COMPONENT 21 Flue Cap 230-2473 x1 230-2298 x2 230-2323 x3 230-2344 x4 22 106-4309 Door Assembly, with Liner (also used for HD63 fryers) * 200-8076 Panel, Door, Inner * 210-8075 Panel, Door, Outer 23 n/a Door Assembly (C/C) 24 210-8077 Handle, Door, Chrome 25 n/a Handle, Common Cabinet * 810-2346 Magnet, Door * 803-0337 Fry Basket, 6 x 83⁄4" x 163⁄4" 26 803-0149 Grid Assembly, Mesh * 810-2235 Grid Assembly, Rack 27 823-5859 Basket Hanger, Church's (with Deflector) * 823-5801 Basket Hanger, Chili’s Single System, 6” Splash Guard * 823-5856 Splash Guard (2-, 4-, 5-, and 6-battery) 28 810-1494 Caster, Plate-mount 4" without Brake 29 810-2406 Caster, Plate-mount 5" without Brake 30 812-1226SP Drain Nipple, Extended * 807-0154 Cordset, 10’ Power 31 210-9416 Cover, Outlet Duct 32 810-2411 Leg, Single Bolt Mount (black) * 810-3169 Leg Package, 4 Bolt Mount (4 per set) 33 823-3248 Leg Support Assembly 34 200-8835 Burner Mounting Rail * 200-8168 Post, Door * 210-2804 Duct, Door Access * Not illustrated.

Page 57 of the Frymaster FPHD user manual — 2.2 Orifices
Page 57 · click to enlarge
Page 57

2.2 Orifices

ITEM PART # COMPONENT Natural Orifices * 810-2938 0-1999 ft. * 810-3053 2000-3999 ft. * 810-3054 4000-5999 ft. * 810-3055 6000-7999 ft. * 810-3056 8000-8999 ft. * 810-3057 9000-10000 ft. Propane Orifices * 810-2939 0-1999 ft. * 810-3058 2000-3999 ft. * 810-3059 4000-5999 ft. * 810-3060 6000-7999 ft. * 810-3061 8000-8999 ft. * 810-3062 9000-10000 ft. * Not illustrated.

Page 58 of the Frymaster FPHD user manual — 2.3 Control Panel Options, Joiner Strips, and Accessories
Page 58 · click to enlarge
Page 58

2.3 Control Panel Options, Joiner Strips, and Accessories

Frymaster FPHD — 2.3 Control Panel Options, Joiner Strips, and Accessories diagram (page 58)
Fig. 65 · 2.3 Control Panel Options, Joiner Strips, and Access…

ITEM PART # COMPONENT Control Panels 1 210-3562 Controller, x1 (HD150, SCFHD456) 2 210-3021 Solid, with Indicator Light, x1 (SCFHD160, 260, 360, 460) 3 210-6405 Controller, x1 (HD60/SCFHD60) 4 106-7661 Controller, x2 (HD260) 5 230-2087 Controller, x2 (FPHD265/565/665) 6 200-8108 Vent, Computer (FPHD265/565/665; for use with Item 7) 7 106-5653 Controller, x3 (FPHD365/565) 8 106-7021 Controller, x4 (FPHD465) 9 211-6640 Frame End, Left (FPHD65, HD63) 10 212-6640 Frame End, Right (FPHD65, HD63) * 106-6085 Controller, x3 (HD663 with matching cabinet) * 106-4574 Controller, x4 (HD663 with matching cabinet) Joiner Strips * 210-3017 HD60, SCFHD60, FPHD65 * 823-5961 FPHD565/665 (for use between two fryer banks) * 823-5947 FPHD665 (for use within one fryer bank) * 230-1465 SCFHD456 * 823-5932 SCFHD50 Accessories * 823-3938 Crumb Scoop, Split Pot * 106-2631SP Sediment Tray * 823-3947 Chicken Crisper * Not illustrated.

Page 59 of the Frymaster FPHD user manual — 2.4 Optional Components and Controllers
Page 59 · click to enlarge
Page 59

2.4 Optional Components and Controllers

Frymaster FPHD — 2.4 Optional Components and Controllers diagram (page 59)
Fig. 66 · 2.4 Optional Components and Controllers

ITEM PART # COMPONENT 1 826-2013 Thermostat, Sunne 2 810-2035 Knob, Thermostat 3 826-2117 Spark Module, Domestic and CE (Rajah Connector, 807-4375) * 106-7535 Ignition Cable (for computer operated fryers) 4 807-1311 Pilot Assembly, Natural Gas with Electronic Ignition * 807-1553 Pilot Assembly, LP Gas with Electronic Ignition * 106-1839SP Pilot Assembly (w/computer and electronic ignition), Natural * 810-2155 Pilot Assembly (w/computer and electronic ignition), LP * Not illustrated.

Frymaster FPHD — 2.4 Optional Components and Controllers diagram (page 59)
Fig. 67 · 2.4 Optional Components and Controllers
Page 60 of the Frymaster FPHD user manual — 2.4 Optional Components and Controllers (cont.)
Page 60 · click to enlarge
Page 60

2.4 Optional Components and Controllers (cont.)

ITEM PART # COMPONENT * 106-1238 Pilot Assembly (without computer), Natural * 807-1310 Flame Sensor * 803-0278 Brush, L-shaped * 803-0197 Fryer’s Friend * 803-0293 Gloves (pair) * KIT00092 Air Shutter Kit 5 ►►► See Control Panel Options, Joiner Strips, and Accessories, Section 2.3 6 Controllers * 106-7324SP Computer, Compu-Fry III.5, Full-vat * 106-7437SP Generic Digital Controller * 106-3028 Computer, CM4-S (Church's; with bezel) * 106-5023 Computer, CM4-S (Popeye's) * 106-2599 Basket Lift Timer * 807-4199 Cable Assembly, Computer to Interface Board (SMT) 7 Bezels * 823-3806 HD/SCFHD50 * 823-0768 SCFHD456 * 823-3776 SCFHD60 * 823-3433 FPHD65 * 230-0021 FPHD565 x2 * 230-0665 FPHD565 x3 8 826-2269 Potentiometer, Dean (without resistor) * 826-2086 Kit, Thermatron, 115/230V * 106-3729 24V Thermatron Board * 816-0534 Knob, Thermatron Controller * 210-5236 Face Plate, 3-switch, Thermatron * 807-3580 Switch, Rocker Black, Thermatron * 807-3579 Switch, 6 Prong, Thermatron * 807-3576 Switch, Reset-Rocker, Thermatron * 807-3575 Switch Hole Plug, Thermatron 9 807-3485 Thermopile 10 812-1284 Thermocouple (CE ONLY) * 807-1026 Sound Device 11 106-1768SP ECO Connector, Honeywell Valves Only (CE ONLY) * 810-2398 ECO Connector, Robertshaw Valves Only (CE ONLY) 12 106-5419 Probe Assembly, Temperature (Thermatron) * 826-2423 Probe Assembly, Temperature (Dean computer) 13 210-6564 Bracket, Pilot Thermocouple 14 810-2401 Bracket, Thermopile 15 810-1001 Piezo Igniter (trigger) * 200-1868 Piezo Bracket * 807-3540 Electrode, Piezo * 807-3650 Lead Wire, Piezo 16 807-3551 Transformer, Honeywell 120/24 VAC (threaded mounting/electronic ignition) * 807-0855 Transformer, 120/12 VAC * 807-0800 Transformer, 120/24 VAC * 807-1999 Transformer, Dual CE (CE ONLY, 208-240/12-24V) 17 807-3560 High-limit Thermostat, Manual Reset 410° F (CE) * 807-3680 High-limit Thermostat, Manual Reset 450° F (NON-CE, 1998-present) * Not illustrated.

Page 61 of the Frymaster FPHD user manual — 2.4 Optional Components and Controllers (cont.)
Page 61 · click to enlarge
Page 61

2.4 Optional Components and Controllers (cont.)

ITEM PART # COMPONENT * 807-3559 High-limit Thermostat, Manual Reset 435° F (pre-1998) * 210-4628 Bracket, Frypot Sensors (requires tack welding to heat tube) * 210-4629 Bracket, Frypot Computer Probe (requires tack welding to heat tube) 18 807-1321 Fuse Holder, Buss * 2747 Fuse Holder, Slot-head, Safety (CE ONLY) * 807-3592 Fuse 2A Slow-blow (230V systems) * 807-3750 Fuse 5A (120V systems) 19 Interface Boards * 106-6669 Constant Pilot * 106-6710 Standing Pilot 20 807-0834 Relay, 12VDC 15A 1PDT (basket lift) 21 807-0833 Relay, 12VDC 5A 1PDT (latching) * 807-4114 Relay, 24VAC Coil, Reset 22 807-3574 Switch, Power (green lens) 23 807-3580 Switch, Rocker, Manual Filter Power 24 807-3579 Switch, Six-terminal Boil-out 25 807-3576 Switch, Fryer Reset (momentary) 26 210-2786 Switch Guard (for Items 22-25, optional) * 807-3578 Switch, 3-position, ON-OFF-ON * 807-3592 Fuse, 2A, Slow Blow * 807-3577 Circuit Breaker, 7 amp * 807-3582 Indicator Light, Green * 807-3581 Indicator Light, Red * 106-1414 Pump Relay * 807-3575 Switch Insert, Blank * 106-2625 Basket Lift Timer, 120V, 60 Hz * Not illustrated.

Page 62 of the Frymaster FPHD user manual — 2.5 3” Oil Drain Manifold, Drain Flush, and Drain Valve Components
Page 62 · click to enlarge
Page 62

2.5 3” Oil Drain Manifold, Drain Flush, and Drain Valve Components

Frymaster FPHD — 2.5 3” Oil Drain Manifold, Drain Flush, and Drain Valve Components diagram (page 62)
Fig. 68 · 2.5 3” Oil Drain Manifold, Drain Flush, and Drain Va…
Page 63 of the Frymaster FPHD user manual — 2.5 3” Oil Drain Manifold, Drain Flush, and Drain Valve Components (cont.)
Page 63 · click to enlarge
Page 63

2.5 3” Oil Drain Manifold, Drain Flush, and Drain Valve Components (cont.)

ITEM PART # COMPONENT 1 823-5880 Drain Tube, Down Spout/Center Dump (SCFHD50) * 823-5968 Drain Tube, Down Spout/Center Dump (FPHD65) * 823-5881 Drain Tube, Down Spout/Center Dump (SCFHD60/80) * 812-1802 Clamp, Down Spout Location * 220-0873 Bracket, Drain Tube Location 2 823-4680 Drain Tube, Left (SCFHD50/60/80) * 823-4844 Drain Tube, Left (SCFHD60) 3 823-4681 Drain Tube, Right (SCFHD50/60/80) * 200-9365 Drain Tube, Right, Filter (FPHD65) * 823-5188 Drain Tube, Right, Filter (SCFHD50/60/80) 4 200-6751 Drain Tube, Joiner (SCFHD50) 5 823-4682 Drain Tube, Joiner (SCFHD50/60/80) 6 809-0969 Clamp, T-bolt 7 816-0625 Boot/Sleeve * 106-2568SP Wash Down Hose Assembly (includes handle and nozzle) * 106-1837SP Quick Disconnect, Female, with 1⁄2" collar * 813-0699 Quick Disconnect, Male, 1⁄2" * 810-1434 Hose Assembly, 66", with both ends 1⁄2" NPT * 106-1454SP Nozzle Assembly, with handle * 106-2387 Heater Strip 120V, 25W, 36”, with 2-pin male connector Flush Oil Drain Line 8 813-0686 Bell Reducer, 1 1⁄2" x 1⁄2" 9 813-0165 Elbow, Street 1⁄2" x 1⁄2" NPT 90° BM 10 810-1669 Adapter, Female 5⁄8" O.D. x 1⁄2" Long 11 810-1668 Adapter, Male 5⁄8" O.D. x 1⁄2" Long 12 810-1056 Flexline, 5⁄8" O.D. x 52.5" Long 106-3976 Drain Valve Assembly, 11⁄2" without Microswitch 106-3977 Drain Valve Assembly, 11⁄2" with Microswitch 13 810-2783 Drain Valve, 11⁄2" Full Port with O-ring * 816-0544 O-ring Seal 14 823-4734 Handle, Drain Valve Rotating 15 807-2104 Microswitch, CE Micro-roller Lever 16 106-5511 Microswitch Bracket Assembly 17 220-0143 Guard, Drain Microswitch 18 816-0220 Insulation, RF Switch 19 816-0547 Cap, Red Vinyl for Handle 20 200-6116 Strap, 11⁄2" (holds tube to valve via the stud) 21 809-0988 Washer, Drain Microswitch, Teflon 22 200-1257 Retainer, Drain Valve 23 826-1366 Nut, 4-40 Keps Hex w/External Teeth (pkg. of 25) * 816-0665 Cap, Vinyl (one per clamp, covers T-bolt threads) * Not illustrated.

Page 64 of the Frymaster FPHD user manual — 2.6 Oil Return Manifold Components
Page 64 · click to enlarge
Page 64

2.6 Oil Return Manifold Components

Frymaster FPHD — 2.6 Oil Return Manifold Components diagram (page 64)
Fig. 69 · 2.6 Oil Return Manifold Components
Frymaster FPHD — 2.6 Oil Return Manifold Components diagram (page 64)
Fig. 70 · 2.6 Oil Return Manifold Components
Page 65 of the Frymaster FPHD user manual — 2.6 Oil Return Manifold Components (cont.)
Page 65 · click to enlarge
Page 65

2.6 Oil Return Manifold Components (cont.)

ITEM PART # COMPONENT 106-4080 Oil Return Manifold, End (SCFHD50) 106-5616 Oil Return Manifold (SCFHD250) 106-4101 Oil Return Manifold, End (SCFHD60) KIT9342 Oil Return Manifold (SCFHD260) 106-6468 Oil Return Manifold, #1 (FPHD) 106-6469 Oil Return Manifold, #3 (FPHD) 106-6471 Oil Return Manifold, #4 (FPHD) 106-6470 Oil Return Manifold, #1, #2, #5, #6 (FPHD) 106-5499 Oil Return Manifold, Chili's (SCFHD460) 1 106-4006SP Valve Assembly, 1⁄2" Oil Return (see Section 2.7) * 106-3997 Valve Assembly (use with wand) 106-6797 Valve Assembly, 3-way Oil Return, Over-the-Top (FPHD, non-C/C) 2 210-9643 Spring Clip 3 210-9915 Cover, Dean Oil Return Microswitch 4 210-9916 Support, Dean Microswitch Mount 5 807-2104 Switch, CE Micro Roller Lever 6 809-0045 Nut, Cap 10-32 Hex 7 809-0056 Nut, 5/16-18 Hex 8 809-0117 Screw, 10-32 x 3/8 Slotted Truss Head 9 809-0237 Nut, 4-40 Keps Hex w/ Extended Teeth 10 809-0256 Nut, Keps 10-32 Hex 11 809-0354 Screw, 4-40 x ¾ Round Head 12 809-0942 Washer, 5/16 Belleville, 18-8 13 810-1003 180°, 3-way Ball Valve 14 816-0220 Insulation, Switch 15 106-5229 Support, Oil Return Valve 16 823-5952 Handle, 3-way Valve (FPHD; FPHD565 uses 823-5363) 17 810-1668 Adapter, Male 5⁄8" OD x 1⁄2" 18 810-1067 Flexline, 8.5” Oil Return * 810-1055 Flexline, 11.5” Oil Return * 810-1056 Flexline, 52.5” Oil Return * 810-1069 Flexline, 29.50" Oil Return 19 813-0003 Tee, 1⁄2" x 1⁄2" x 1⁄2" BM 20 813-0022 Nipple, 1⁄2" x Close NPT BM 21 813-0099 Nipple, 1⁄2" x 7.00" NPT BM 22 813-0165 Elbow, Street 1⁄2" x 1⁄2" NPT 90° BM 23 813-0173 Union, 1⁄2" NPT 24 813-0247 Nipple, 1⁄2" x 3.50" NPT BM 25 813-0362 Nipple, 1⁄2" NPT x 7.50" BM 26 813-0463 Plug, 1⁄2" Counter Sink 27 813-0661 Nipple, 1⁄2" x 2.25" NPT BM 28 813-0654 Nipple, 1⁄2” x 4.00” NPT BM 29 813-0597 Nipple, 1⁄2“ x 11.50” NPT BM * 813-0062 Elbow, 1⁄2", 90° BM * 813-0087 Nipple, 1⁄2" x 1.50" NPT BM * 813-0460 Nipple, 1⁄2" x 3.00" NPT BM * 813-0672 Nipple, 1⁄2" x 8.00" NPT BM * 813-0607 Nipple, 1⁄2" x 23.5” NPT BM * 813-0646 Nipple, 1⁄2" x 5.00" NPT BM * 813-0373 Nipple, 1⁄2" x 11.00" NPT BM

Page 66 of the Frymaster FPHD user manual — 2.6 Oil Return Manifold Components (cont.)
Page 66 · click to enlarge
Page 66

2.6 Oil Return Manifold Components (cont.)

ITEM PART # COMPONENT * 813-0298 Nipple, 1⁄2" x 2.00" NPT BM * 813-0098 Nipple, 1⁄2" x 6.50" NPT BM * 813-0265 Nipple, 1⁄2" x 2.50" NPT BM * 813-0093 Nipple, 1⁄2" x 4.00" NPT BM * 813-0281 Nipple, 1⁄2" x 5.00" NPT BM * 813-0368 Nipple, 1⁄2" x 16.00" NPT BM * 813-0698 Nipple, 1⁄2" x 10.5" NPT BM * Not illustrated.

Page 67 of the Frymaster FPHD user manual — 2.7 Oil Return and Oil Flush Components
Page 67 · click to enlarge
Page 67

2.7 Oil Return and Oil Flush Components

4 5 6 8

Page 68 of the Frymaster FPHD user manual — 2.7 Oil Return and Oil Flush Components
Page 68 · click to enlarge
Page 68

2.7 Oil Return and Oil Flush Components (cont.) ITEM PART # COMPONENT 106-4006SP Microswitch Bracket Assembly, Oil Return 1 901-2772 Handle, RF Left 2 900-2935 Retainer, Nut 3 816-0220 Insulation, RF Switch 4 810-0278 Ball Valve, 1⁄2" Oil Return 5 826-1366 Nut, 4-40 Keps Hex w/External Teeth (pkg. of 25) 6 807-2103 Microswitch, Straight Lever (CE) 7 200-6806 Cover, Safety Switch 8 106-3962 Bracket Assembly, RF Switch Oil Suction Assembly 9 813-0062 Elbow, 90° BM 10 813-0173 Union, 1⁄2" NPT 150# BM 11 813-0654 Nipple, TBE 1⁄2" NPT x 4" Black 12 813-0674 Nipple, TBE 1⁄2" NPT x 71⁄4" Black 13 200-1230 Bracket, Front Male Manifold 106-0774SP Suction Manifold Assembly 14 810-0697 Disconnect, Male Suction Tube * 826-1392 O-rings, for Male Disconnect (pack of 5) 15 813-0608 Coupling, 1⁄2" NPT BM Full 16 823-3188 Suction Manifold 106-0858 Oil Suction Start Fitting 17 813-0022 Nipple, 1⁄2" NPT x Close 18 813-0463 Plug, 1⁄2" Counter Sink 19 813-0003 Tee, 1⁄2" NPT BM * 210-8790 Bracket, Oil Return/Flush Retainer * 200-8929 Handle, Oil Return * 200-9850 Handle, Oil Return (Application Series “DF” fryers) * 816-0638 Cap, Oil Return Handle, Yellow * 816-0637 Cap, Oil Return Handle, Blue Pump and Motor 20 807-3859 Motor (HD50/60 C/C, HD63, FPHD65) * 810-2100 Motor (HD50/60, non-C/C) 21 810-3071 Pump, 8GPM (Viking, C/C) 22 810-2098 Pump, 8GPM (Dean, non-C/C) * 810-2716 Pump, 2-piece 4GPM (Viking, HD56) * Not illustrated.

Page 69 of the Frymaster FPHD user manual — 2.8 Filtration Components 2.8.1 Filtration Components; SCFHD50 Series Fryers
Page 69 · click to enlarge
Page 69

2.8 Filtration Components 2.8.1 Filtration Components; SCFHD50 Series Fryers

ITEM PART # DESCRIPTION 106-5144SP Filter Pan Assembly (includes Items 1-8) 1 823-4841 Filter Pan 2 823-5639 Lid, Filter Pan 3 823-3573 Ring, Hold Down 4 823-5191 Crumb Basket 5 200-8003 Screen, Sana Grid 6 810-2805 Caster, 2” 7 809-0823 Nut, Nylock, 1⁄4-20 8 813-0568 Pipe Plug, 1/8 NPT Socket-head 9 803-0170 Filter Paper, 16.5” x 25.75” (100 sheets per box) * Not illustrated.

Page 70 of the Frymaster FPHD user manual — 2.8.2 Filtration Components; SCFHD60 and SCFHD63 Series Fryers
Page 70 · click to enlarge
Page 70

2.8.2 Filtration Components; SCFHD60 and SCFHD63 Series Fryers

ITEM PART # COMPONENT 106-7543 Filter Pan Assembly (includes Items 1-8) 1 823-6001 Filter Pan 2 106-4725 Lid Assembly 3 823-6018 Crumb Basket 4 823-3361 Hold Down Ring 5 200-5726 Screen, Bottom Filter 6 810-2805 Caster, 2” 7 809-0823 Nut, 1⁄4-20 Hex S/S 8 813-0568 Pipe Plug, 1⁄8" NPT Socket Head 9 803-0289 Filter Paper, 22” x 34” (100 sheets; 803-0266, 25 sheets) * Not illustrated.

Page 71 of the Frymaster FPHD user manual — 2.8.3 Filtration Components; FPHD65 Series Fryers
Page 71 · click to enlarge
Page 71

2.8.3 Filtration Components; FPHD65 Series Fryers

ITEM PART # COMPONENT 106-5081 Filter Pan Assembly (includes Items 1, 3-6) 1 823-5258 Filter Pan 2 823-5857 Lid Assembly 3 823-5851 Crumb Basket 4 106-6466 Filter Leaf and Tube 5 810-2805 Caster, 2” 6 809-0070 Nut, ¼-20 Hex S/S * Not illustrated.

Page 72 of the Frymaster FPHD user manual — 2.9 Basket Lift Components
Page 72 · click to enlarge
Page 72

2.9 Basket Lift Components

Frymaster FPHD — 2.9 Basket Lift Components diagram (page 72)
Fig. 71 · 2.9 Basket Lift Components
Frymaster FPHD — 2.9 Basket Lift Components diagram (page 72)
Fig. 72 · 2.9 Basket Lift Components
Page 73 of the Frymaster FPHD user manual — 2.9 Basket Lift Components (cont.)
Page 73 · click to enlarge
Page 73

2.9 Basket Lift Components (cont.)

ITEM PART # COMPONENT 106-1870 Basket Lift Assembly (HD60) 1 823-3625 Basket Lift 2 809-0082 Truarc Ring, 3/4" 3 200-2735 Channel, Support Autolift 4 200-2069 Member, Lift Control Arm 5 810-2140 Bushing (Oiltite) 3⁄8" x 1⁄2" 6 813-0035 Bushing (Bronze), .641/.640 ID 7 824-0958 Back, Basket Lift Motor (D60) 8 824-0959 Cover, Basket Lift Motor (D60) 9 200-1376 Bracket, Restraining 10 106-1463 Motor Assembly * 200-1693 Plate, Motor Mounting * 807-0107 Gear Motor * 807-2104 Microswitch, CE Roller * 807-3546 Bushing, Heyco, 750-625 (3/4") * 810-2144 Spacer, Aluminum, 1⁄4" OD x 3⁄8" L, #4-40 11 823-3626 Switch, Limit Cam Motor Housing 12 200-2736 Housing, Front 13 200-2739 Housing, Bottom 14 200-2364 Housing, Back 15 807-0140 Connector, 3⁄8" 16 823-5904 Left Basket Lift Arm 17 823-5905 Right Basket Lift Arm 18 823-3500 Basket Lift Guide Plate (HD60) * Not illustrated.

Page 74 of the Frymaster FPHD user manual — 2.10 Trough, Holster, & Cover Components
Page 74 · click to enlarge
Page 74

2.10 Trough, Holster, & Cover Components

ITEM PART # COMPONENT 1 106-2668SP Holster Assembly, Vat Cover 2 823-3384 Trough, Holster Assembly * 106-1637SP Cover, Full-vat (HD50) 3 106-1447SP Cover, Full-vat (HD60) 4 106-2585SP Cover, Split-vat (HD60) * 106-2897SP Cover (FPHD65) * 106-6494 Cover (HD56) * 810-0180 Handle, Vat Cover (Full- and Split-) * 823-4767 Splash Guard * 803-0278 L-shaped Brush * 803-0197 Fryer’s Friend * 823-3938 Crumb Scoop * Not illustrated.

Page 75 of the Frymaster FPHD user manual — 2.11 Fasteners (Screws, Nuts, Bolts)
Page 75 · click to enlarge
Page 75

2.11 Fasteners (Screws, Nuts, Bolts)

ITEM PART # COMPONENT * 809-0842 Nut, 4-40 Nylock * 809-0417 Nut, Flange 1⁄4-20 Serrated * 809-0766 Nut, Keps 10-32 SS Hex * 826-1366 Nut, 4-40 Keps Hex w/External Teeth (pkg. of 25) * 809-0247 Nut, Nylock, #4-40 * 809-0842 Nut, 8-32 Hex Keps (Zinc Plated) * 809-0863 Nut, Nylock, 5⁄16"-18 Hex * 809-0169 Screw, #12 x 3⁄4" Hex Washer Slotted Head * 809-0428 Screw, 1⁄4-20 x 1⁄2” Hex Head * 826-1389 Screw, 1⁄4-20 x 3⁄4" Hex Head (pkg. of 10) * 809-0918 Screw, 10-24 x 1⁄2" Slotted Head * 809-0845 Screw, 10-32 x 3⁄8" Hex Slotted Head * 809-0846 Screw, 4-40 x 1" * 809-0918 Screw, 8-32 x 3⁄8" Round Slotted Head * 809-0167 Screw, Sheet Metal 10 A x 5⁄8 B * 809-0434 Screw, #10 x 3⁄8" Hex Washer Head * 809-0907 Screw, .375 x 1⁄2" Shoulder * 826-1379 Screw, #10 x 1⁄2" Phillips Truss Head (pkg. of 10) * 809-0962 Screw, 8-32 x 1-3⁄8" Phillips Truss Head * 809-0997 Washer, 1⁄2 SAE “N” S/S * 809-0191 Washer, 1⁄4" Spring-lock * Not illustrated.

Page 76 of the Frymaster FPHD user manual — PRINTED IN THE UNITED STATES SERVICE HOTLINE
Page 76 · click to enlarge
Page 76
Frymaster FPHD — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 76)
Fig. 73
Frymaster FPHD — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 76)
Fig. 74
Frymaster FPHD — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 76)
Fig. 75
Frymaster FPHD — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 76)
Fig. 76
Frymaster FPHD — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 76)
Fig. 77

Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000

Shipping Address8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 FAX (Tech Support) 1-318-219-7135

PRINTED IN THE UNITED STATES SERVICE HOTLINE

1-800-551-8633 819-6314 MAY 2007

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Burner will not ignite. Light in ON/OFF switch is not illuminated.A. ON/OFF switch is off.A. Turn ON/OFF switch on. p.41
ON/OFF switch is on, but the switch light is not illuminated.A. No voltage at switch.A. Ensure line voltage is present at the switch. p.41
ON/OFF switch is on and the switch light is illuminated, but there is no output to gas valve.A. Drain microswitch circuit (filter- equipped units) is open.A. Ensure drain valve is fully closed and microswitch is functioning. Replace microswitch if defective. p.41
ON/OFF switch is on and the switch light is illuminated, but there is no output to gas valve.B. Voltage is present at ON/OFF switch, but continuity of the switch in ON position is not "0.”B. ON/OFF switch is defective. Replace switch with a known working switch. p.41
ON/OFF switch is on and the switch light is illuminated, but there is no output to gas valve.C. Continuity of thermostat is not "0" (oil temperature is at least 15°F below electronic thermostat setting).C. Thermostat(s) is/are defective. Replace defective thermostat with a known working thermostat. p.41
ON/OFF switch is on and the switch light is illuminated, but there is no output to gas valve.D. Gas valve is suspect.D. Go to "No burner flame" section. p.41

Ask about the Frymaster FPHD

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster FPHD

Be the first to ask — other owners or our team will answer.

Original document

Frymaster FPHD manual PDF

76 pages·6.6 MB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…