INCLUDED INCLUDED INCLUDED INCLUDED
Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633 MARCH 2004

Please read all sections of this manual and retain for future reference.
professional should perform installation, maintenance, and repairs. Installation, maintenance,
or repairs by unqualified personnel may void the manufacturer’s warranty. See Chapter 1 of
this manual for definitions of qualified personnel.
the country and/or region in which the appliance is installed. See NATIONAL CODE
REQUIREMENTS in Chapter 3 of this manual for specifics.


service instructions thoroughly before installing or servicing this equipment. Only qualified
service personnel may convert this appliance to use a gas other than that for which it was originally configured. See Chapter 1 of this manual for definition of qualified service personnel.

anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all
from slips or contact with the hot oil.
other appliance.

must be posted in a prominent location. This information can be obtained from the local gas
company or gas supplier.

at the end of frying operations each day. Some food particles can spontaneously combust if left
soaking in certain shortening material. Additional information can be obtained in the filtration
manual included with the system.

the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for





THIS PAGE INTENTIONALLY LEFT BLANK.

1.1 After Purchase In order to improve service, have the following chart filled in by the Frymaster/Dean Authorized Service Technician who installed this equipment.
Address Telephone/Fax Model Number Serial Number Gas Type 1.2 Ordering Parts Customers may order parts directly from their local factory authorized service center. For this address and phone number, contact your factory authorized service center or call the Frymaster/Dean Service Hotline phone number, 1-800-551-8633. To speed up your order, provide the model number, serial number, gas type, part needed, item part number (if known), and quantity needed. 1.3 Service Information Call the Frymaster/Dean Service Hotline, 1-800-551-8633, for the location of your nearest factory authorized service center. To assist you more efficiently, always provide the service technician with the model number, gas type, serial number, and the nature of the problem. 1.4 Computer Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.
Authorized Service Technician/FASC

1.4 Computer Information (cont.) The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. 1.5 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below.

1.6 Service Personnel 1.6.1 Definitions A. Qualified and/or Authorized Operating Personnel
1. Qualified service personnel are those who are familiar with Frymaster/Dean equipment and have been authorized by Frymaster/Dean to perform service on Frymaster/Dean equipment. All authorized service personnel are required to be equipped with a complete set of service parts manuals and stock a minimum amount of parts for Frymaster/Dean equipment. A list of Frymaster/Dean Factory Authorized Service Centers (FASCs) was included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Frymaster/Dean warranty on your equipment.

THIS PAGE INTENTIONALLY LEFT BLANK.

A. Check that the containers are upright. Use an outward prying motion - no hammering - to
remove the cartons. Unpack fryers carefully and remove all accessories from the carton and/or frypots. Do not discard or misplace accessories, as they will be needed during final assembly and fryer operation.
B. After unpacking, immediately check the equipment for visible signs of shipping damage. If
damage has occurred, contact the carrier and file the appropriate freight claims. Do not contact the factory. Shipping damage responsibility is between the carrier and the dealer.
If your equipment arrives damaged:
from pallet.
installed on the frying system and unloading ramps are furnished to facilitate removal of the units off the pallets. Remove pallet supports from underneath fryer and carefully roll the unit down the ramps from the front (cooking side). See assembly instructions shipped with unit for system assembly.
E. Remove all plastic skin from sides, front, and doors of the fryers. Units are shipped with
plastic skin to protect the stainless components from surface damage during shipping. Failure to remove the plastic prior to initial fryer operation will make it very difficult to remove later.

2.2 General Qualified, licensed, and/or authorized installation or service personnel only (as defined in Section 1.6) should perform the following:
Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Receiving and Unpacking Equipment in Section 2.1.) 2.2.1 Product Description Frymaster FPD65 Series gas fryers are energy efficient, tube-style, gas-fired units. All units are shipped completely assembled with accessories packed inside the frypot. Frymaster FPD65 Series gas fryers are adjusted, tested and inspected at the factory before shipment. The input rates of this model are listed in this manual.
the inherent hazards of operating a hot oil frying system, particularly the aspects of
system operation, oil filtration, draining and cleaning procedures.

2.3 Principles of Operation The incoming gas flows through orifices and is mixed with air in the burners to create the correct ratio for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot light. Internal diffusers slow the flame as it goes through the burner tube. This slower and more turbulent flame gives much better heat transfer to the walls of the tubes, thereby heating the oil better.
2.4 Rating Plate
This is attached to the inside front door panel. Information provided includes the model and serial number of the fryer, BTU/hr input of the burners, outlet gas pressure in inches W.C. and whether the unit has natural or propane gas orifices.
plate.
Hotline at 1-800-551-8633.
this chapter. A. General: Only licensed personnel should install any gas-fired equipment.

2.5 Pre-Installation (cont.) B. Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design-
certified for the following installations:
American National Standard Institute CAN 1-B149 Installation Codes ANSI Z83.11 Canadian Gas Association American Gas Association 55 Scarsdale Road 8501 E. Pleasant Valley Road Don Mills, ONT, M3B 2R3 Cleveland, OH 44131 National Electrical Code Canadian Electric Code c22.1, part 1 ANSI/NFPA #70 Canadian Standards Association American National Standard Institute 178 Rexdale Blvd. 1430 Broadway Rexdale, ONT, M9W 1R3 New York, NY 10018 NFPA Standards #96 and #211 National Fire Protection Association 470 Atlantic Avenue Boston, MA 02110

2.6 Air Supply and Ventilation
of unacceptable concentrations of substances harmful to the health of personnel in
the room in which it is installed.
Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow as well as for service and maintenance.
A. Do not connect this fryer to an exhaust duct.
B. Correct installation and adjustment will ensure adequate airflow to the fryer system.
C. A commercial, heavy-duty fryer must vent its combustion wastes to the outside of the
building. A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan must be provided in the wall above the unit, as exhaust gas temperatures are approximately 800-1000°F (427-538°C). Check air movement during installation. Strong exhaust fans in the exhaust hood or in the overall air conditioning system can produce slight air drafts in the room.
D. Do not place the fryer’s flue outlet directly into the plenum of the hood, as it will affect the
gas combustion of the fryer.
E. Never use the interior of the fryer cabinet for storage or store items on shelving over or
behind the fryer. Exhaust temperatures can exceed 800°F (427°C) and may damage or melt items stored in or near the fryer. F. Adequate distance must be maintained from the flue outlet of the fryer(s) to the lower edge
of the filter bank. Per NFPA Standards No. 96, a minimum of 18-inches (45-cm) should be maintained between the flue(s) and the lower edge of the exhaust hood filter.
G. Filters and drip troughs should be part of any industrial hood, but consult local codes before
constructing and installing any hood. The duct system, the exhaust hood and the filter bank must be cleaned on a regular basis and kept free of grease. 2.7 Equipment Installed at High Altitudes
A. The fryer input rating (BTU/hr) is for elevations up to 2,000 feet (610-m). For elevations
above 2,000 feet (610-m), the rating should be reduced four percent for each additional 1,000 feet (305-m) above sea level.
B. The correct orifices are installed at the factory if operating altitude is known at time of the
customer’s order.

THIS PAGE INTENTIONALLY LEFT BLANK.

3.1 Installing the Fryer Decathlon 65 Series fryer systems are shipped in sections. The fryers are uncrated, removed from pallets and assembled together. Important aspects during assembly include aligning and connecting the drain system, oil return system, rinse-line system (where applicable), oil-return switch wiring harness and fryer cabinets. Slight modifications to connecting hardware may be required when assembling the system. The instructions below provide step-by-step instructions to assist the installer in assembly. For this procedure, the fryers are numbered from right to left as follows: Fryers #1, #2, #3, #4, #5 and #6 (where applicable). 1. Open the doors of the filtration fryer cabinet. Remove filter pan from the cabinet. Uncrate fryers and remove the pallet supports. Install ramps and slowly roll the fryer(s) off the pallets. 2. Remove door from fryers to be connected by lifting the door upward and removing the door pin from the bottom hinge. Remove slip-nuts from drain-tees on fryers being connected, lubricate O-rings with vegetable oil and install on drainpipe (Fig. 2). Use care not to damage the slip-nut O-rings when installing slip-nut on drainpipe. Insert the drainpipe into the fryer drain-tee (Fig. 3). Screw slip-nut onto the tee but do not tighten at this time. Position fryers being connected within 6 inches of each other, near the permanent installation area. Guide the drainpipe through the opposite fryer cabinet opening as the cabinets are positioned.
Figure 1. Remove pallet supports (arrow) before removing fryers from pallets.
Properly align the drainpipe evenly between the two drain-tees using the "blue" marks on the tube
ends to prevent leaks and/or blocked drain
valves.
Figure 2. Slip-nut/drainpipe detail.
Figure 3. Insert drainpipe section into fryer drain-tee before pushing fryers together (arrow). Do this as required for all cabinets being assembled.

3.1 Installing the Fryer (cont.) 3. Connect red/white or red/yellow wires (Figure 4, left) between fryer sections being assembled (Figure 4, right, arrow). Oil-return will not operate properly if these wires are not connected.
NOTE: On systems shipped in three or more sections, additional wiring between cabinets will exist. Ensure all wires are connected before completing cabinet assembly. 4. Remove the lower back panel-strips on fryers being assembled to gain access to the oil return and rinse-line connections (Figure 5, arrows). Back removal may not be required on some systems. 5. Slowly push the two cabinets together. Ensure the drainpipe and slip-nut are aligned with the drain-tee on the opposite fryer section. Ensure the oil-return and rinse-hose connections (where applicable) on each fryer section are aligned. Ensure oil-return switch wires between cabinet sections are not pinched when the cabinets are brought together. Pull excess wire through the opposite fryer side as the cabinets are brought together. Secure excess wire inside cabinet with a wire tie. 6. With the cabinets together, insert the drainpipe into the opposite fryer drain-tee and position it evenly between the fryers being connected. Connect the oil-return and rinse-lines by accessing the oil return union through the lower fryer-back openings. Connect all fittings, but do not tighten at this time. 7. Align the cabinet connection holes, front and back (Figure 6, arrow). Connection hardware is included in the accessories pack. Insert bolts and install nuts, but do not tighten. If holes do not align, use a 3/16" drill-bit and drill through the misaligned hole. 8. Install the frypot joiner strip between cabinet sections (Figure 7; also see factory-installed strips on two-battery cabinet sections).
Figure 4. Oil return wires between sections must be connected for oil-return operation.
Figure 5. Oil return and rinse-line (where applicable) connections.
Figure 6. Cabinet connection locations inside cabinet sections (front shown).
Figure 7. Install joiner strip(s) after fryers are connected.

3.1 Installing the Fryer (cont.) 9. Install the front connecting post on the connected cabinets (Figure 8; see factory-installed posts on two-battery fryer sections). 10. Complete installation of topcap battering strips after the front connecting post has been installed (Figure 9).
Figure 8. Installing front connecting post on connected fryer sections.
NOTE: Systems shipped in three or more sections will require the installation of topcaps and other components prior to installing topcap-battering strips. See Topcap Installation Instructions for these systems. 11. Install the rear connecting plate (Figure 10). Remove four screws from the cabinet backs (Figure 10, arrows), install connecting plate and replace screws. Connection strips vary from system to system. 12. At the fryer front: Tighten the drain manifold slip-nuts. Install doors removed at the beginning of assembly. At the fryer back: Tighten the oil- return line and rinse-line (where applicable) union(s). 13. Reinstall filter pan after fryer start-up has been performed (boil-out, burner adjustment, etc.) NEVER ALLOW WATER OR BOILOUT SOLUTION INTO FILTER SYSTEM.
Figure 9. Complete installation of topcap battering strips (arrow) after installing front connecting post(s) on connected fryers.
Check all connections for leaks. Ensure all components operate properly.
Figure 10. Install rear connecting plate.

3.1 Installing the Fryer (cont.)


must be removed from the fryer before attempting to move it to avoid oil spills, and
the falls and severe burns that could occur. This fryer may tip and cause personal

to remove all foreign material. Foreign material in the burner and gas controls will
cause improper and dangerous operation. NATIONAL CODE REQUIREMENTS This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration. This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect equipment stamped "NAT" only to natural gas and that stamped "PRO" only to LP (Propane) gas.
Quick disconnect devices, if used, shall likewise comply with national and local codes.

number plate located on the back of the fryer door.

3.2 Gas Connections (cont.)

A. The gas supply (service) line must be the same size or greater than the fryer inlet line. This
fryer system is equipped with three 1" (28 mm) female inlets (one inlet per two fryers). The gas supply line must be sized to accommodate all the gas-fired equipment that may be connected to that gas supply. Consult your contractor, gas company, supplier, or other knowledgeable authorities.

Gas Types Number of Fryers 1 2 to 3 4 or more (*) Natural Gas 3/4" (22 mm) 1" (28 mm) 1-1/4" (35 mm) Propane Gas 1/2" (15 mm) 3/4" (22 mm) 1" (28 mm) (*) When exceeding 18 feet for a configuration of more than four fryers, it is necessary to provide
a 1-1/4" (35 mm) rigid gas connection.
used and all connections must be tested with a solution of soapy water before
lighting any pilots.
Never use matches, candles, or any other ignition source to check for leaks. If gas
odors are detected, shut off the gas supply to the appliance at the main shut-off
valve and immediately contact the local gas company or an authorized service
agency for service.
unit.
chips, or any other foreign matter before installing into a service line. If the intake pipes are not clear of all foreign matter, the orifices will clog when gas pressure is applied. Seal pipe joints with a sealant resistive to LP gas. When using thread compound on gas piping, use very small amounts and only on male threads. Use a pipe thread compound that is not affected by the chemical action of LP gases. DO NOT apply thread compound to the first two pipe threads—doing so will cause clogging of the burner orifices and control valve.

3.2 Gas Connections (cont.) C. Manual shut-off valve: This gas service supplier-installed valve must be installed in the gas
service line ahead of the fryers in the gas stream and in a position where it can be reached quickly in the event of an emergency.
supply during any pressure testing of the system.
line if the test pressure is ½" PSI [3.45 kPa (14 inches W.C.)] or greater to avoid
damage to the fryer’s gas piping and gas valve(s).
manometer.

3.2 Gas Connections (cont.)
I. Flexible Couplings, Connectors and Casters:
Personal injury may result. 2. The fryer must be restrained by means independent of the flexible coupling or connector in order to limit the movement of the fryer. Clips are located on the back panel of the fryer for the attachment of restraints.
A. Proper operation of Frymaster/Dean gas fryers requires operator to inspect the following
adjustments in terms of:
B. Frymaster/Dean gas fryers are manufactured to use the type of gas and pressure specified on
the rating plate. When changing to a different gas, adaptation must be performed by qualified personnel. Failure to use qualified personnel will void the Frymaster/Dean warranty.

3.3.1 Specifications 3.3.1.1 Adjustments to Different Gas Types

* Gas pressure may vary per fryer model and altitude. Check the rating plate for specific gas pressures.
Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame- volume is achieved.) 3.3.2 Gas Conversion Procedures

from one gas type to another requires the installation of specific gas-conversion
Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as
defined in Section 1.6 of this manual.

Pilot pressure adjustment (remove cover screw to access)
Pressure flow adjustment (remove cover screw to access)
3.4 Electrical Connections The fryer when installed must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70-(latest edition).
ON/OFF Gas-Cock Knob Pilot gas supply connection.
receptacle. DO NOT CUT, REMOVE, OR OTHERWISE BYPASS THE GROUNDING
PRONGS ON THESE PLUGS! The rating plate and wiring diagram are located inside the front door. The fryer is equipped with a 120VAC single-phase 60-hertz system (Domestic), or 230VAC single-phase 50-hertz system (International/CE). Do not cut or remove the ground prong from any of the power cord plugs. Do not attempt to use the fryer during a power outage.
the OFF position in case of a prolonged power outage. Do not attempt to operate
this appliance during a power outage.
Typical gas valve · Regulator Vent

THIS PAGE INTENTIONALLY LEFT BLANK.


the inherent hazards of operating a hot oil frying system, particularly the aspects of
system operation, oil filtration, draining and cleaning procedures. Cleaning: New units are wiped clean with solvents at the factory to remove any visible signs of dirt, oil, grease, etc. remaining from the manufacturing process, then coated lightly with oil. Before any food preparation, wash thoroughly with hot, soapy water to remove any film residue and dust or debris then rinse out and wipe dry. Also wash any accessories shipped with the unit. Close the drain valve completely and remove the crumb screen covering the heating tubes. Ensure the screws holding the thermostat and high-limit control sensing bulbs into the frypot are tight.


Typical high-limit/sensor probe locations and mounting hardware.

a tight fit and should only be removed for cleaning.

water or cooking oil/shortening before lighting the burners. Failure to do so will


4.1.1 Pilot Lighting Procedures, Electronic Ignition Systems Initial Pilot Lighting: All Frymaster/Dean fryers are tested, adjusted and calibrated to sea level conditions before leaving the factory. Adjustments to assure proper operation of pilot may be necessary on installation to meet local conditions, low gas pressure, differences in altitude and variations in gas characteristics. These adjustments correct possible problems caused by rough handling or vibration during shipment, and are to be performed only by qualified service personnel. These adjustments are the responsibility of the customer and/or the dealer and are not covered by the Frymaster/Dean warranty. The inlet pipe at the lower rear of the fryer brings incoming gas to the pilot safety control valve, then to the pilot and main burners. The pilot is located high in the cabinet center, at the base of the frypot.
WARNING Never use a match or taper to light pilot on this ignition system. 1. Turn gas "ON". 2. Turn electric power "ON" with the appropriate rocker switch or controller/computer. 3. The ignition module will energize the pilot gas supply and the ignitor. The ignitor spark will ignite the pilot gas. The presence of the pilot flame is then proved by a flame sensor, which sends a signal to the main gas supply, opening the valve. The operating thermostat or computer/controller controls the fryer after ignition.
out the system. Turn the unit power "OFF" and them back "ON" after power has
been re-established. 4. If the pilot flame fails, the ignition module will shut down and lock out the system. To restart, turn the electric power "OFF", wait approximately 5 minutes for the system to recycle itself, then turn the power "ON" again. Repeat Steps 1-3.

4.2 Boil-Out Procedure
boils over, turn the fryer off immediately and let the solution cool for a few minutes before resuming the process. To lessen the chance of boil over, turn the fryer’s gas
valve knob to the PILOT position occasionally.
or a portable filter unit. These units are not intended for this purpose, and will be
damaged by the solution.
shortening is heated to cooking temperature and may cause injury to nearby
personnel.
A. Pour cleaning solution into the frypot and add water to the bottom OIL LEVEL line scribed
in the back of the frypot.
above that of boiling water.
reset switch (if applicable). Turn the boil-out switch "ON".

least 5 minutes before lighting. D. The main burner will ignite.
E. When the solution nears boiling point, reset the temperature controller to 200°(93ºC).
F. The burners should shut off just as the water starts to boil.

left unattended. Press ON/OFF switch to the "OFF" position (Filtration/Boil-Mode equipped fryers) or reduce temperature (Operating Thermostat equipped fryers) to
control this condition.

4.2 Boil-Out Procedure (cont.)
G. The burners will heat the boil-out solution to a simmer. Simmer the solution for
approximately 45 minutes. Wearing protective gloves, scrub the sides of the frypot and the tubes with the L-shaped Teflon brush, being careful not to disturb the temperature sensing probes and the high-limit thermostat.
H. Do not allow the water level to decrease below the bottom OIL LEVEL line in frypot during
boil-out operation.
I. After boil out is complete, turn the computer off. Drain the solution from the frypot. Place a metal stockpot of sufficient size to safely hold the entire contents of the frypot under the drain port to collect the water/boil-out solution. Do not allow water or boil-out solution to drain into the filter pan. The filter pump is not designed for water operation, and will be irreparably damaged (see warning statement above).
J. Close the drain, add fresh water (without boil-out solution) and wash all surfaces of the frypot. Drain again.
K. Refill the frypot with fresh water and vinegar to neutralize any residual boil-out solution.
Wash all surfaces of the frypot. Drain completely and wipe down all surfaces of the frypot to completely remove all water.
above procedures for boil-out.
Always wear oil-proof, insulated gloves when working with the fryer filled with hot
oil.
Always drain hot oil into a metal stockpot of sufficient size to safely hold the entire
contents of the frypot.

4.3 Final Preparation
will damage the heating tubes and frypot, and void the warranty. 4.3.1 Filling Fryer with Cooking Oil/Shortening
A. When using a liquid shortening (cooking oil), fill the fryer to the bottom OIL LEVEL line
scribed into the back of the frypot.
B. When using a solid shortening, cut it into small pieces and pack it below the heat tubes,
between the tubes and on top of the tubes, leaving no air spaces around the tubes. Do not disturb or bend the probe sensing bulbs.
C. Press the computer on/off switch to "ON". The burners will initially operate in the MELT
CYCLE mode until the shortening reaches 180°F. It will then automatically switch to normal operation.
D. When the frypot is filled and the shortening is melted, carefully replace the crumb screen
over the heat tubes. Wear oil-proof insulated gloves to avoid the potential for burn injury when placing crumb screen in frypot. For additional computer instructions, see computer manual that came with frying system.

THIS PAGE INTENTIONALLY LEFT BLANK.

operational procedures. 5.1 General Frymaster FPD65 Series gas fryer filter systems come equipped with a filter-leaf assembly, which eliminates the need for filter paper. Filter powder is used to enhance the filtration process. 5.2 Filtration Preparation On initial installation and before each use, remove all loose parts from the filter, wash the filter pan and all accessories in hot, soapy water and dry thoroughly. 5.2.1 Assembling the Filter Frymaster FPD65 Series filter systems incorporate a filter-leaf assembly, in which a fine mesh screen is used to filter impurities and debris from the oil. The oil is pumped through the screen and then returned to the frypot. Assemble the filter pan as follows (see illustration below): 1. Filter pan assembly.

5.2.1 Assembling the Filter (cont.) Assemble the filter as follows: 1. Remove the filter pan covers. 2. Place the filter leaf assembly in the bottom of the filter pan, ensuring the filter disconnect is properly placed in the filter pan slot. Support the screen assembly by holding the supply pipe during installation. 3. Ensure the filter screen lies flat in the bottom of the pan and the supply connection bracket is properly positioned in the pan slot before proceeding.
Filter pan with covers removed.
The bracket fits into a slot in the pan.
Filter leaf properly positioned in filter pan.

5.2.1 Assembling the Filter (cont.) 4. Place the crumb tray in filter pan. 5. Replace the pan covers and install the filter pan into the cabinet. Ensure the connections are fully engaged. Ensure the filter pan opening is directly under the drain tubes to avoid splashing hot oil. The fryer is ready for filtering.
Crumb screen placement in filter pan.
The filter pan slides under the fryer (above), connecting with a slip fitting (right). The slip fitting is located between the drain tubes (above, arrow).

5.3 Daily Filtration Operation

350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position prior to operating any switches or valves. Failure to do this can
result in severe burns.

operational procedures. 5.3.1 General Overview The filter pump is turned on only after the oil is brought to operating temperature and drained into the prepared filter pan. The filter motor is then engaged and oil is drawn through the filter leaf assembly and pumped back into the frypot. The frypot drain valve remains open during the filtering process. The oil is cycled through the filter leaf assembly for approximately 10 minutes (see computer section for specific instructions). At the end of 10 minutes, the drain valve is closed, allowing the oil to pump back into the frypot. The pump should run for 15-30 seconds after bubbles appear in the frypot to ensure all oil or shortening is pumped from the drain pan and the oil-return lines. The frypot oil level should return to the top OIL LEVEL line. If not, add fresh oil or shortening to obtain the proper level. Remember, the oil is at operating temperature during all filtration procedures. The filter pump can be activated with a manual On/Off switch located under the fryer control panel if the oil-return, drain-flush or wand/dispose valves fail to activate the pump when opened. Contact an authorized service technician immediately for repair. Refer to specific store procedures for correct filter operation. Additional information can be found in the computer section of this manual.
procedure.

5.3.2 Filtering Tools Assemble tools to be used for filtering. These are supplied with the filter starter kit included with the fryer/filter system:
store procedures are obtained.
one frypot ONLY.

5.4 Operating the Filter 5.4.1 Filter Operation
(~177°C)]. 1. Remove fry baskets from frypot. Prior to filtering, skim any large debris from the oil with the fine mesh skimmer. Use extreme caution, as oil is at or near operating temperature [~350°F (~177°C)]. Use a metal scraper to gently remove debris from frypot walls above shortening level. 2. Pour 12 ounces by volume of filter powder into the vat. Carefully stir the powder into the oil with the fine mesh skimmer. 3. Ensure the oil is at operating temperature (~350°F/177°C). Open the fryer drain valve. Allow the oil to drain into the filter pan. The computer will display OPEN DRAIN.
Prior to filtering, skim any large debris from oil in frypot.
Adding filter powder to vat prior to filtering.
Pull red handle to open drain valve and allow hot shortening to drain into filter pan.

5.4.1 Filter Operation (cont.) 4. When all the oil has drained from the frypot, connect the hose-wand assembly to the disconnect valve in the fryer cabinet. DO NOT ACTIVATE FILTER PUMP UNTIL THE HOSE HAS BEEN PROPERLY CONNECTED. Ensure the hose-disconnect is properly connected before proceeding. Remove the frypot wire rack prior to rinsing frypot. 5. Place the hose wand into the frypot being filtered and activate the rinse valve by turning the blue handle to "WAND" (where applicable), or by pressing the manual bypass switch (systems without oil disposal system). The filter pump will activate and oil will start flowing through the rinse hose. 6. Hold the wand inside the frypot at a 45- degree angle while the rinse valve is opened. 7. Use the wand to rinse debris from the frypot for approximately 3 minutes. At the end of 3 minutes, the computer display will alternate from OPEN DRAIN to the timed countdown cycle (10 minutes). Turn the blue handle or the manual bypass switch to "OFF", and then close the drain valve (red handle). Disconnect and drain the hose of all shortening or oil. Hang hose upright to ensure no shortening remains in hose.
Hose/wand disconnect properly connected to disconnect valve in fryer cabinet (orientation of disconnect may vary according to system).
After the hose wand end is properly positioned in the frypot, activate the filter pump by turning the blue handle to "WAND" (where applicable).
Use the wand to rinse debris from the frypot into the filter pan. Maintain a firm grip on the wand handle at all times.

5.4.1 Filter Operation (cont.) 8. Begin the filtering process by pulling the yellow handle to open the oil-return valve (this activates the filter pump automatically). 9. Oil will begin to pump from the filter pan into the frypot. Allow the oil to circulate through the frypot for the remainder of the timed countdown (approximately 10 minutes). This process is known as "polishing". 10. The computer will display FILL at the end of the timed countdown. Replace the frypot grid rack. Close the red drain valve handle to begin refilling the frypot.
Begin the filtering process by pulling yellow handle to open oil return valve. Leave the drain valve (red handle) open during the filtering process.
Polishing the oil removes suspended particles, which increases the life of the oil.
When the computer displays FILL, close the drain valve to begin refilling the frypot.

5.4.1 Filter Operation (cont.) 11. After all shortening is pumped back into the frypot, bubbles will form, indicating air in the oil return lines. Allow the shortening to bubble for 15-30 seconds to ensure all shortening is cleared from the return lines. An audible alarm will sound, indicating that the frypot is full. Push the yellow handle to close the oil return valve and deactivate the filter pump. 12. If the shortening level is low, add fresh shortening until the level is at the top OIL LEVEL line (the shortening is at operating temperature). 13. Do not allow crumbs to accumulate in the crumb tray. The crumb tray MUST be emptied into a fireproof container at the end of frying operations EACH day.
Allow the oil to bubble for 15-30 seconds to ensure evacuation of all oil in the return lines.
Add fresh shortening until the level is at the top OIL LEVEL line. DO NOT OVERFILL THE FRYPOT.
Empty the filter pan crumb tray into a fire-proof container at the end of frying operations each day. DO NOT ALLOW CRUMBS TO ACCUMULATE IN TRAY.

5.4.1 Filter Operation (cont.) 14. OPTIONAL EQUIPMENT: Drain-flushes are included on 5-battery and larger Frymaster FPD65 Series fryers. After filtering frypot farthest from the filter system for 10 minutes, close the oil return valve to stop the filtering process. Do not refill the frypot. Close the drain valve (red handle) on the frypot being filtered. Ensure all other valves (red and yellow handles) are closed. Pull the blue handle to open the flush valve (6-battery systems have two). After the drain line is clear of sediment (approximately 2 minutes), push the blue handle to close flush valve. Open the oil-return valve (yellow handle) to refill the frypot. 15. OPTIONAL EQUIPMENT: Shortening Disposal: Follow store procedures when disposing of spent shortening. Ensure the Shortening Disposal System is properly connected and working properly before proceeding. Turn the blue handle on the wand/dispose valve to "DISPOSE" to start the disposal process. Turn the blue handle to "OFF" when the disposal process for that frypot is complete.
Left drain-flush handle location (arrow) for frypot #6.
Blue handle in "DISPOSE" position. Turn handle to "OFF" after spent shortening is disposed of.
can spontaneously combust if left soaking in certain shortening material.
a tight fit and should only be removed for cleaning.


cooking temperature, it will cause spattering of the oil/shortening, which can result
Any equipment works better and lasts longer when maintained properly and kept clean. Cooking equipment is no exception. Frymaster FPD65 Series gas fryers should be kept clean during the working day, and thoroughly cleaned at the end of each day. Below are recommendations for daily, weekly and periodic preventative maintenance.
6.1.1 Daily

contact surfaces. Read the directions and precautionary statements for use. Particular attention must be paid to the concentration of cleaner and the length of
A. Remove and wash all removable parts.
B. Clean all exterior surfaces of the cabinet. Do not use cleaners, steel wool, or any other
abrasive material on stainless steel.
C. Filter the cooking oil and replace if necessary. The oil should be filtered more frequently
when under heavy use.
D. Clean filter pan, as well as, crumb tray as discussed on page 5-9. 6.1.2 Weekly
A. Completely drain the oil from the fryer into a metal stockpot of sufficient size to safely hold
the entire contents of the frypot for disposal. Do not use a glass or plastic container.
B. Clean the frypot by following boil-out procedures in Chapter 4.2.


FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 6: PREVENTATIVE MAINTENANCE

FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 6: PREVENTATIVE MAINTENANCE
6.1.3 Periodic/ Annual (cont.) • Check filtration system integrity as follows: − With the filter pan empty, place each oil return handle, one at a time, in the "ON" position.
Verify that the pump activates and that bubbles appear in the cooking oil/shortening of the associated frypot. − Close all oil return valves (i.e., place all oil return handles in the "OFF" position). Verify proper
functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot. − Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to
350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the "ON" position. Allow all cooking oil/shortening to return to the frypot (indicated by bubbles in the cooking oil/shortening. Return the oil return handle to the "OFF" position. The frypot should refill in no more than 2 minutes and 30 seconds. To ensure good fryer health and a safe environment, the fryer should be checked and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program.
6.1.4 Stainless Steel Care
burns. All stainless steel fryer cabinet parts should be wiped regularly with hot, soapy water during the day, and with a liquid cleanser designed for stainless steel at the end of each day.
A. Do not use steel wool, abrasive cloths, cleansers or powders.
B. Do not use a metal knife, spatula or any other metal tool to scrape stainless steel! Scratches
are almost impossible to remove.
C. If it is necessary to scrape the stainless steel to remove any encrusted materials, soak the area
first to soften the deposit, then use a wood or nylon scraper only.

THIS PAGE INTENTIONALLY LEFT BLANK.

appliance when filled with hot cooking oil/shortening or to transfer hot cooking
oil/shortening from one container to another.
tests are required. Use extreme care when performing such tests.
This appliance may have more than one electrical power supply connection point.
Disconnect all power cords before servicing.
Inspection, testing and repair of electrical components should be performed by an
authorized service agent only. The problems and possible solutions covered are those most commonly encountered. To troubleshoot, perform the test set-up at the beginning of each condition. Follow each step in sequence. 7.2 Pilot Burner Malfunction
A. Pilot will not ignite; no evidence of gas at pilot burner.
B. Pilot burner ignites but will not remain lit when gas valve manual knob is released.

7.2 Pilot Burner Malfunction (cont.)
C. Pilot flame of proper size, but is unstable. Flame wavers and does not envelop the
thermopile completely at all times.
A. Main burner will not come "ON"; gas not detected at main burner.
B. Main burner flames are small and appear lazy; shortening does not come up to temperature
quickly.
C. Signs of excessive temperature; shortening scorches and quickly becomes discolored.

7.3 Main Burner Malfunctions (cont.)
D. Fryer will not reach the temperature setting and/or runs erratically.
E. Fryer shortening temperature cannot be controlled; fryer runs at high-limit temperature.

7.4 Wiring Diagram, Main

TO J2 COMPUTER INTERFACE BOARD
5 4 3 2 1 9 8 7 6 14 13 11 10 12 15
5 3 4 2 8 9 7 6 14 12 13 11 15
LINE VOLTAGE

7.5 Wiring Diagram, Filter
8051428A

OFF POSITION SHOWN IN
LEADS T5 AND T8 ON THE MOTOR FOR CHANGE OF ROTATION INTERCHANGE

THIS PAGE INTENTIONALLY LEFT BLANK.



8.1 Cabinetry and Related Components (cont.)
ITEM PART # COMPONENT 1 810-0357 Caster, 5" Swivel – With Brake 2 810-0356 Caster, 5" Swivel – Without Brake 3 823-3248 Support, Caster- Channel Base 4 202-1182 Gusset, Side Panel- Left 5 201-1182 Gusset, Side Panel- Right 6 200-1463 Channel, Base- Front & Rear- 2-Battery (FPD565 & FPD665) * 200-2493 Channel, Base- Front & Rear- 1-Battery (FPD565 Only) 7 200-1198 Channel, Base- UFF Filter 8 823-3352 Support, Caster- UFF Base 9 200-1493 Frame, Base Lower Plate- UFF 10 200-1611 Base, Upper- UFF 11 200-4241 Plate, Motor Support- Offset 12 200-2308 Post, Door- UFF Cabinet 13 200-1393 Channel, Lower Joiner 14 200-1471 Duct, Door Access 15 202-1299 Panel, Side- Painted- Right 16 201-4775 Panel, Inner- Left 17 202-4775 Panel, Inner- Right 18 201-4237 Panel, Inner UFF- Left 19 202-4237 Panel, Inner UFF- Right 20 201-1299 Panel, Side- Painted- Left 21 823-3826 Fluecap 22 200-3696 Back, Upper Structural (FPD665) * 200-3694 Back, Upper Structural (FPD565) * 200-1376 Bracket, Restraining 23 200-1425 Back, Lower Structural- Right & Left Cabinet 24 200-4238 Back, Lower Structural- Middle UFF Cabinet 25 210-3700 Hanger, Basket- 2-Battery * Not Illustrated

8.2 Doors, Topcaps and Related Components

8.3 Frypots, Burners and Related Components

8.3 Frypots, Burners and Related Components (cont.)
ITEM PART # COMPONENT 1 823-3948 Frypot- S/S- 65 Series 2 210-5170 Diffuser, Burner Tube 3 810-2150 Burner, Right 4 810-2149 Burner, Center 5 810-2151 Burner, Left * 200-2738 Bracket, Burner Mounting * 200-2746 Shield, Burner Heat 6 200-1615 Bracket, Manifold Mounting 7 809-0822 Bolt, ¼-20 x ½" Hex Head 8 809-0823 Nut, Nylock- ¼-20 9 810-2138 Valve, Trailing Pilot 10 813-0642 Tee, 1/8" NPT 11 813-0705 Plug, Brass- 1/8" Square Head 12 813-0643 Nipple, 1/8" NPT x Close BM 13 810-2050 Orifice, Natural- #44 (2.18 mm) * 810-2324 Orifice, LP- #53 (1.40 mm) 14 823-3617 Manifold, Gas 15 807-3628 Valve, Gas- LP-24V, Honeywell * 807-3552 Valve, Gas- Natural-24V, Honeywell 16 813-0174 Union- ¾" NPT BM 17 813-0635 Nipple, ¾ NPT x 2-½" BM 18 813-0066 Elbow- ¾" NPT 90° BM 19 813-0743 Nipple, ¾ NPT x 3-½" BM 20 813-0165 Elbow, Street- ½" NPT 90° BM 21 813-0670 Nipple, ½ NPT x 19" BM (Measure To Confirm Length) * 813-0585 Nipple, ½ NPT x 20-½" BM (Measure To Confirm Length) * 813-0737 Nipple, ½ NPT x 21" BM (Measure To Confirm Length) 22 810-2043 Clamp, Pipe- ½" 23 809-0805 Bolt, Pipe Clamp- ¼-20 x ½" Hex * 200-1450 Bracket, Gas-Supply Clamp Support (UFF-Equipped Systems) 24 807-1553 Burner, Pilot- LP- Electronic Ignition * 807-1311 Burner, Pilot- Natural- Electronic Ignition * 807-1310 Sensor, Flame 25 810-0703 Gas Line, Main Pilot Supply- ¼ x 17-½" * 810-0705 Gas Line, Main Pilot Supply- ¼ x 23" 26 810-2155 Burner, Trailing Pilot- LP * 810-2032 Burner, Trailing Pilot- Natural 27 812-1544 Gas Line, Trailing Pilot Supply- ¼ x 12" (Not For Main Pilot) 28 106-2634SP Flue Assembly, Complete * 200-4086 Shield, Flue Heat * 200-4087 Front, Flue Box * 200-4088 Rear, Flue Box * 200-3649 Deflector, Flue 29 810-2524 Grid, Frypot- 65 Series 30 106-2897SP Cover, Frypot- 65 Series * Not Illustrated

8.4 Component Box Components

ITEM PART # COMPONENT 1 823-3242 Control Box (Inside Non-Filter Fryer Cabinets) 2 210-1364 Plate, Face (For Item #1) 3 200-1322 Bracket, Spark Module 4 200-1326 Cover, Spark Module 5 807-3563 Module, Ignition (Spark) * 807-1315 Cable, Ignition Module 6 806-4549 Board, Interface 7 807-0833 Relay, 12VDC 5A 1PDT (Latching) 8 807-0855 Transformer, 120VAC 50/60 Hz -12V 20VA 9 807-0800 Transformer, 120VAC 50/60 Hz -24V 50VA 10 807-1321 Fuse Holder, Buss * 807-3750 Fuse, 5A 11 807-3580 Switch, Rocker- Manual Filter Power 12 807-3577 Breaker, Circuit- 7-Amp (115VAC Circuits) * 807-3538 Breaker, Circuit- 5-Amp (230VAC Circuits) 13 807-3680 High-Limit Thermostat- Manual Reset 450° F (Non-CE Only) 14 806-7179 Device, Sound 15 200-2052 Bracket, Sound Device 16 807-3611 Relay, Filter- 24VAC Coil 24A 17 106-1541SP Probe, Temperature- Computer 18 806-8305 Computer, CM4-S- With Bezel Generic (Segmented Programming) 106-3028 Computer, CM4-S- With Bezel Church’s Only (Segmented. Prog.) * 823-3433 Bezel, Computer * Not Illustrated

8.5 Filter Pan and Related Components

8.6 Oil-Drain Components

8.6 Oil-Drain Components (cont.)
ITEM PART # COMPONENT 1 823-4189 Pipe, Drain- Right- D665 (With Oil Disposal System) * 823-3441 Pipe, Drain- Right- D565 (No Oil-Disposal System) 2 813-0829 Elbow, Drain Pipe- 75° 3 809-0884 Nut, Slip Joint- 1-½" 4 816-0544 O-ring (Slip-Joint Nut) 5 200-1840 Drain Manifold Tube 6 813-0749 Tee, 1-½" NPT With Handle 7 813-0165 Elbow, Street- ½ x ½" 90° 8 810-1069 Flex Line, 5/8" x 29-½ " (Measure To Confirm Length) 9 810-1057 Flex Line, 5/8 x 13" (Measure To Confirm Length) 10 810-1668 Adapter, 5/8" O.D. x ½"- Male (Use With 810-1057 and 810-1069) 11 813-0062 Elbow, ½" NPT BM 90° 12 813-0096 Nipple, ½ x 6" NPT BM 13 813-0686 Bell Reducer, 1-½ x ½" NPT 14 813-0784 Drain Pipe, Left Side Drain Valve Components 15 106-1401 Bracket, Microswitch (Optional On Some Units) 16 200-1617 Washer, Drain Valve (Use Without Microswitch) 17 210-2029 Bracket, Activator- Microswitch 18 200-1940 Handle (Actuator), Drain Valve * 823-3440 Handle, Push/Pull- Drain (With Cap) * 809-0885 Washer, 3/8 x 1 x .083" * 809-0843 Cotter Pin * 816-0547 Cap, Vinyl-Red 19 807-2104 Microswitch (Optional On Some Units) 20 809-0842 Nut, Nylock- #4-40 (Microswitch To Bracket) 21 816-0220 Insulation, Microswitch 22 200-1257 Retainer, Nut 23 810-2127 Drain Valve, 1-½" Full Port (With Washers & Nut) * Not Illustrated

8.7 Oil-Return Components
Oil Disposal Plumbing · (Optional)

8.7 Oil-Return Components (cont.)
ITEM PART # COMPONENT 3 813-0173 Union, ½" NPT BM 4 813-0003 Tee, ½" NPT BM 5 813-0165 Elbow, Street ½" NPT BM 90° 6 813-0051 Coupling, ½" NPT BM 7 813-0062 Elbow, ½" NPT BM 90° 8 810-1003 Valve, Ball- Three-Way ½" 180° * 823-4234 Handle, Wand/Disposal * 210-4239 Bracket, Wand/Disposal Handle * 816-0549 Cap, Handle- Blue (Cut Length To Fit) 9 106-1837SP Disconnect Assembly, With Collar 10 810-0278 Valve, Ball- Oil-Return ½" * 823-3187 Handle, Oil-Return Valve * 816-0548 Cap, Oil-Return Handle- Yellow * 823-4174 Handle Assembly (Actuator)- Oil-Return Valve * 809-0885 Washer, Actuator- Ball Valve- 3/8 x 1 x 0.083" 11 813-0463 Plug, Counter-Sink Hex ½" Oil Disposal Components 12 810-1056 Flexline, Oil Disposal- 5/8 x 52-½" 13 823-3996 Nipple Assembly, Oil Disposal 14 810-0487 Disconnect, Male- Oil Disposal 15 810-1669 Adapter, Female- 5/8 x ½" * 810-0278 Handle, Oil-Return Flush Valve * 816-0549 Cap, Flush Valve Handle- Blue 16 810-2098 Pump, Filter- 8GPM 17 810-2100 Motor, Filter Pump- 120/230VAC 1/3 HP * Not Illustrated 8.8 Suction Tube, Oil-Return Components


8.8 Suction Tube, Oil-Return Components (cont.)
ITEM PART # COMPONENT 1 810-0697 Disconnect, Male- Suction Tube * 826-1392 O-ring, Suction Tube Connection (Qty: 5) 2 813-0608 Coupling, Full- ½" NPT BM 3 823-3188 Suction Manifold Assembly 4 813-0062 Elbow, ½" x 90° NPT BM 5 813-0093 Nipple, ½ NPT x 4" NPT BM 6 813-0173 Union, ½" NPT BM 7 813-0165 Elbow, Street- ½" x 90° NPT BM 8 Oil Suction Start Fitting 813-0022 Nipple- ½" NPT x Close BM 813-0156 Plug, ½" NPT BM Hex Head 813-0003 Tee, ½" NPT BM * Not Illustrated

THIS PAGE INTENTIONALLY LEFT BLANK.


Frymaster, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 FAX (Tech Support) 1-318-219-7135
1-800-551-8633 819-6039 JANUARY 2004
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.