EN
Frymaster logo
Official user manual

Frymaster E4

36 pages·1.1 MB·Fryer·PDF·ENDEFRITNLJA
Frymaster E4
Table of Contents 19 sections RE SERIES E 4 ELECTRIC FRYERS · Installation & Operation Manual · *8196149* · NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS · … ShowHide
Page 1 of the Frymaster E4 user manual — *8196149*
Page 1 · click to enlarge
Page 1
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS diagram (page 1)
Fig. 1

RE SERIES E 4 ELECTRIC FRYERS

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS diagram (page 1)
Fig. 2

Installation & Operation Manual

Frymaster E4 — Installation & Operation Manual diagram (page 1)
Fig. 3 · Installation & Operation Manual
Frymaster E4 — Installation & Operation Manual diagram (page 1)
Fig. 4 · Installation & Operation Manual
Frymaster E4 — Installation & Operation Manual diagram (page 1)
Fig. 5 · Installation & Operation Manual
Frymaster E4 — Installation & Operation Manual diagram (page 1)
Fig. 6 · Installation & Operation Manual
Frymaster E4 — Installation & Operation Manual diagram (page 1)
Fig. 7 · Installation & Operation Manual

Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

24-Hour Service Hotline 1-800-551-8633 FEB 2009

*8196149*

www.frymaster.com E-mailservice@ frymaster.com
Page 2 of the Frymaster E4 user manual — DANGER
Page 2 · click to enlarge
Page 2

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS

U.S.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.

CANADA

This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications.

Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.

DANGER

Page 3 of the Frymaster E4 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 3 · click to enlarge
Page 3

The front ledge of this appliance is not a step! Do not stand on the appliance. Serious injury can result from slips or contact with the hot cooking oil/shortening.

Page 4 of the Frymaster E4 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 4 · click to enlarge
Page 4
Page 4 of the Frymaster E4 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 5 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS
Page 5 · click to enlarge
Page 5

RE SERIES E 4 ELECTRIC FRYERS

CHAPTER 1: INTRODUCTION

1.1 General Read the instructions in this manual thoroughly before attempting to operate this equipment. This manual covers all configurations of FPRE14, FPRE17, and FPRE22 models. The fryers in this model family have most parts in common, and when discussed as a group, will be referred to as “RE Series Electric” fryers. Although similar in appearance to the Pro Series Electric family of Common Electric fryers, the RE Series Electric fryers feature a significantly different rotating element with an enhanced design. Other features, including the deep cold-zones, open frypots and filtration system remain essentially unchanged. Control options include multi-product cooking computers (standard) or optional digital and analog controllers. Fryers in this series come in full- or split-pot arrangements, and can be purchased as single units or grouped in batteries of up to six fryers. 1.2 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the one below.

DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your system and/or cause your system to malfunction. Fryers in this series are equipped with the following automatic safety features: 1. Two high-temperature detection features shut off power to the elements should the temperature controls fail. 2. A safety switch built into the drain valve prevents the elements from heating with the drain valve even partially open.

Page 6 of the Frymaster E4 user manual — CHAPTER 1: INTRODUCTION
Page 6 · click to enlarge
Page 6

1.3 Computer Information

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense. The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. 1.4 European Community (CE) Specific Information The European Community (CE) has established certain specific standards regarding equipment of this type. Whenever a difference exists between CE and non-CE standards, the information or instructions concerned are identified by means of shadowed boxes similar to the one below.

CE Standard Example of box used to distinguish CE and

Non-CE specific information.

1.5 Installation, Operating, and Service Personnel Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.6. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6. 1.6 Definitions QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.

Page 7 of the Frymaster E4 user manual — CHAPTER 1: INTRODUCTION
Page 7 · click to enlarge
Page 7

QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in person or through a representative, are engaged in and are responsible for the installation of electrical appliances. Qualified personnel must be experienced in such work, be familiar with all electrical precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qualified service personnel are those who are familiar with Frymaster equipment and who have been authorized by Frymaster, L.L.C. to perform service on the equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a minimum amount of parts for Frymaster equipment. A list of Frymaster Factory Authorized Service Centers (FASC) is included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Frymaster warranty on your equipment. 1.7 Shipping Damage Claim Procedure What to do if your equipment arrives damaged: Please note that this equipment was carefully inspected and packed by skilled personnel before leaving the factory. Frymaster does not assume responsibility for damage or loss incurred in transit. The freight company assumes full responsibility for safe delivery upon acceptance of the equipment. 1. File Claim for Damages Immediately—Regardless of extent of damage. 2. Visible Loss or Damage—Be sure this is noted on the freight bill or express receipt and is signed by the person making the delivery. 3. Concealed Loss or Damage—If damage is unnoticed until equipment is unpacked, notify the freight company or carrier immediately and file a concealed damage claim. This should be done within 15 days of date of delivery. Be sure to retain container for inspection. 1.8 Service Information For non-routine maintenance or repairs, or for service information, contact your local Frymaster Authorized Service Center (FASC). Service information may also be obtained by calling the Frymaster Technical Services Department (1-800-24FRYER) or by e-mail at service@frymaster.com. The following information will be needed in order to assist you efficiently:

Model Number Serial Number Voltage Nature of the Problem

RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.

Page 8 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 8 · click to enlarge
Page 8

RE SERIES E 4 ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS

2.1 General Proper installation is essential for the safe, efficient, trouble-free operation of this appliance. Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6 of this manual, should perform all installation and service on Frymaster equipment. Failure to use qualified, licensed, and/or authorized installation or service personnel (as defined in Section 1.6 of this manual) to install or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel. Where conflicts exist between instructions and information in this manual and local or national codes or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed. Service may be obtained by contacting your local Factory Authorized Service Center.

Page 9 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 9 · click to enlarge
Page 9

DANGER Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over and cause injury. The appliance area must be kept free and clear of combustible material at all times. In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power switch OFF. Do not attempt to start the fryer(s) until power is restored. This appliance must be kept free and clear of combustible material, except that it may be installed on combustible floors. A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for servicing and proper operation.

WARNING Do not block the area around the base or under the fryers. 2.1.2 Electrical Grounding Requirements All electrically operated appliances must be grounded in accordance with all applicable national and local codes, and, where applicable, CE codes. All units (cord connected or permanently connected) should be connected to a grounded power supply system. A wiring diagram is located on the inside of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages. 2.1.3 Australian Requirements To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.

Page 10 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 10 · click to enlarge
Page 10

2.2 Power Requirements

Three (3) Phase Requirements MODELVOLTAGEWIRE SERVICEMINIMUM WIRE SIZE AWG (mm)AMPS (per leg) FPRE1420836 (4.11)39 FPRE1424036 (4.11)34 FPRE1448038 (2.59)17 FPRE14220/38046 (4.11)21 FPRE14240/41546 (4.11)20 FPRE14230/40046 (4.11)21 FPRE1720836 (4.11)48 FPRE1724036 (4.11)41 FPRE1748036 (4.11)21 FPRE17220/38046 (4.11)26 FPRE17240/41546 (4.11)24 FPRE17230/40046 (4.11)25 FPRE2220834 (5.19)61 FPRE2224034 (5.19)53 FPRE2248036 (4.11)27 FPRE22220/38046 (4.11)34 FPRE22240/41546 (4.11)31 FPRE22230/40046 (4.11)32
Single Phase Requirements MODELVOLTAGEWIRE SERVICEMINIMUM WIRE SIZE AWG (mm)AMPS (per leg) FPRE1420823 (5.83)68 FPRE1424024 (5.19)59 FPRE1448028 (3.26)30
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 10)
Fig. 8
Page 11 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 11 · click to enlarge
Page 11
1. Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the top of the frypot to verify that the unit is level, both side-to-side and front-to-back.

To level fryers equipped with legs, the bottom of the legs can be screwed out up to one inch for leveling. Legs should also be adjusted so that the fryer(s) are at the proper height in the frying station.

For fryers equipped with casters, there are no built-in leveling devices. The floor where the fryers are installed must be level. When the fryer is leveled in its final position, install the restraints provided with the unit to limit its movement so that it does not depend on or transmit stress to the electrical conduit or connection. Install the restraints in accordance with the provided instructions (see illustration below). If the restraints are disconnected for service or other reasons, they must be reconnected before the fryer is used.

2. Close fryer drain-valve(s) and fill frypot with water to the bottom oil level line. 3. Boil out frypot(s) in accordance with the instructions in Section 5.1.3 of this manual. 4. Drain, clean, and fill frypot(s) with cooking oil. (See Equipment Setup and Shutdown Procedures in Chapter 3.)
Page 12 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS
Page 12 · click to enlarge
Page 12

RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS

FINDING YOUR WAY AROUND THE FPRE SERIES E4 ELECTRIC FRYER

Tilt Housing Basket Hangers

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 12)
Fig. 9

Control Panel (CMIII.5 Computer shown)

Fryer Identification Data Labels (Model and Serial Number)

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 12)
Fig. 10

Drain and Filter Handles

in Filtration Unit Drain

TYPICAL CONFIGURATION (FPRE217 SHOWN) NOTE: The appearance of your fryer may differ slightly from that shown depending upon the configuration and date of manufacture.

Show 8 more labels / short text on this page
Elements · Lift Rods · Top Cap · Bezel · Power Switch · Fuse · FootPrint Pro Built- · Filter Pan
Page 13 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS
Page 13 · click to enlarge
Page 13

3.1 Equipment Setup and Shutdown Procedures

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 13)
Fig. 11
1. Fill the frypot with oil to the bottom OIL LEVEL line located on the rear of the frypot. This will allow for oil expansion as heat is applied. Do not fill cold oil any higher than the bottom line; overflow may occur as heat expands the oil.
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 13)
Fig. 12

When using solid shortening, always pre-melt the shortening before adding it to the frypot. If the shortening is not pre-melted, it must be packed down into the bottom of the frypot and between the elements, and the fryer must be started in the melt-cycle mode.

Never cancel the melt-cycle mode when using solid shortening. Doing so will result in damage to the elements and increase the potential for a flash fire.

2. Ensure that the power cord(s) is/are plugged into the appropriate receptacle(s). Verify that the face of the plug is flush with the outlet plate, with no portion of the prongs visible.
3. Ensure that the power is switched on. Some models are equipped with a master switch located behind the fryer door cabinet on the front panel of the component box, next to the fuse. See page 3-1. standby or off is displayed on the computer.
4. Ensure that the computer / controller is switched ON .
5. Ensure that the oil level is at the top OIL LEVEL line when the oil is at its cooking temperature . It may be necessary to add oil or shortening to bring the level up to the proper mark, after it has reached cooking temperature .

Shutdown 1. Turn the fryer off. 2. Filter the cooking oil and clean the fryers (See Chapters 4 and 5). 3. Place the frypot covers on the frypots.

Setup

Page 14 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS
Page 14 · click to enlarge
Page 14

3.2 Controllers This fryer may be equipped with any of the following controllers:

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 14)
Fig. 13

Computer Magic III.5 (CM III.5)

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 14)
Fig. 14
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 14)
Fig. 15
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 14)
Fig. 16

Solid State (Analog) Controller

Refer to the separate Frymaster Fryer Controllers User’s Manual furnished with your fryer for the specific controller operating instructions. Refer to Chapter 4 of this manual for operating instructions for the built-in filtration system.

Basket Lift Timer · Digital Controller

Page 15 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 15 · click to enlarge
Page 15

RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 15)
Fig. 17

DANGER Draining and filtering of oil must be accomplished with care to avoid the possibility of a serious burn caused by careless handling. The oil to be filtered is at or near 350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position before operating any switches or valves. Wear all appropriate safety equipment when draining and filtering oil.

DANGER When draining oil into a disposal unit or portable filter unit, do not fill above the maximum fill line located on the container. If your fryer is not equipped with a built-in filtration system, the oil must be drained into another suitable METAL container. (For safe, convenient draining and disposal of used oil or shortening, Frymaster recommends using the Frymaster Shortening Disposal Unit (SDU). The SDU is available through your local distributor.) 1. Turn the fryer power switch to the OFF position. Screw the drainpipe (provided with your fryer) into the drain valve. Make sure the drainpipe is firmly screwed into the drain valve and that the opening is pointing down. 2. Position a metal container with a sealable cover under the drainpipe. The metal container must be able to withstand the heat of the oil and hold hot liquids. If you intend to reuse the oil or shortening, Frymaster recommends that a Frymaster filter cone holder and filter cone be used when a filter machine is not available. If you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container.

Page 16 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 16 · click to enlarge
Page 16
3. Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food particles, use the Fryer’s Friend (poker-like tool) to clear the blockage.

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty. 4. After draining the oil, clean all food particles and residual oil from the frypot. BE CAREFUL, this material may still cause severe burns if it comes in contact with bare skin. 5. Close the drain valve securely and fill the frypot with clean, filtered or fresh oil or solid shortening to the bottom OIL-LEVEL line.

DANGER When using solid shortening, pack the shortening down into the bottom of the frypot. DO NOT operate the fryer with a solid block of shortening sitting in the upper portion of the frypot. This will cause damage to the frypot and may cause a flash fire. 4.2 Preparing the Built-In Filtration System for Use The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in operation. The FootPrint Pro filtration system is available in three different configurations:

  • Filter Paper – includes crumb tray, large hold-down ring, and metal filter screen.
  • Filter Pad – includes crumb tray, small hold-down ring, and metal filter screen.
  • Magnasol Filter – includes crumb tray and Magnasol filter assembly. Section 4.2.1 covers preparation of the Filter Paper and Filter Pad configurations for use. Refer to Section 4.2.2 for instructions on preparing the Magnasol Filter configuration for use. Operation of all three configurations is the same and is covered in section 4.3. Disassembly and reassembly of the Magnasol filter is covered in section 4.4.
Page 17 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 17 · click to enlarge
Page 17

4.2.1 Preparation for Use with Filter Paper or Filter Pad 1. Pull the filter pan out from the cabinet and remove the crumb tray, hold-down ring, filter paper and filter screen. (See Figure 1) Clean all components with a solution of detergent and hot water, then dry thoroughly.

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 17)
Fig. 18

The filter pan is equipped with rollers in rails, much like a kitchen drawer. The pan may be removed for cleaning or to gain access to interior components by lifting the front of the pan to disengage the front rollers, then pulling it forward until the rear rollers clear the rails. The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (SDU) to be positioned under the drain. If using an SDU built before January 2004 see instructions on page 4-8. 2. Inspect the filter pan connection fitting to ensure that both O-rings are in good condition. (See Figure 2) 3. Then in reverse order, place the metal filter screen in the center of the bottom of the pan, then lay a sheet of filter paper on top of the screen, overlapping on all sides. (See Figure 1) If using a filter pad, ensure the rough side of the pad is up and lay the pad over the screen, making sure that the pad is in between the embossed ridges of the filter pan. 4. Position the hold-down ring over the filter paper and lower the ring into the pan, allowing the paper to rest on the sides of the filter pan. (See Figure 3)

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 17)
Fig. 19
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 17)
Fig. 20
Page 18 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 18 · click to enlarge
Page 18
5. When the hold-down ring is in position, if using filter paper, sprinkle one packet of filter powder evenly over the paper. (See Figure 4) If using a filter pad, position the hold down ring on top of the pad. DO NOT use filter powder with the pad.
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 18)
Fig. 21

Figure 4 6. Replace the crumb tray in the filter pan, then push the filter pan back into the fryer, positioning it under the drain. 4.2.2 Preparation for Use with the Magnasol Filter Assembly 1. Pull the filter pan out from the cabinet and remove the crumb tray and Magnasol filter assembly. (See Figure 5)

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 18)
Fig. 22

The filter pan is equipped with rollers in rails, much like a kitchen drawer. The pan may be removed for cleaning or to gain access to interior components by lifting the front of the pan to disengage the front rollers, then pulling it forward until the rear rollers clear the rails. The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (SDU) to be positioned under the drain. NOTE: Refer to Section 4.4 for instructions on how to disassemble and reassemble the Magnasol filter screen assembly. 2. Inspect the fitting on the bottom of the Magnasol filter assembly to ensure that the O-ring is present and in good condition. (See Figure 6) 3. Inspect the filter pan connection fitting to ensure that both O-rings are present and in good condition. (See Figure 7)

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 18)
Fig. 23

Inspect the filter screen O-ring.

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 18)
Fig. 24

Inspect the filter connection fitting O-rings.

Page 19 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 19 · click to enlarge
Page 19
4. Replace the Magnasol filter assembly in the filter pan, ensuring that the fitting on the bottom of the assembly is securely seated in the port in the bottom of the pan. Sprinkle one packet of the Magnasol XL filter powder evenly over the screen.
5. Replace the crumb tray, then push the filter pan back into the fryer, positioning it all the way to the back of the cabinet. 4.3 Operation of the Filter
2. Make sure the oil is at operating temperature. 3. Turn the fryer power OFF. Drain the frypot into the filter pan by rotating the valves 90 º . If necessary, use the Fryer's Friend clean-out rod to clear the drain from inside the frypot.
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 19)
Fig. 25
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 19)
Fig. 26

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty.

Page 20 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 20 · click to enlarge
Page 20
4. After the oil has drained from the frypot, turn the filter handle to the ON position to start the pump and begin the filtering process. There may be a slight delay before the pump activates.
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 20)
Fig. 27
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 20)
Fig. 28

Turn filter handle to the ON position

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 20)
Fig. 29
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 20)
Fig. 30
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 20)
Fig. 31
5. The filter pump draws the oil through the filter medium and circulates it back up to and through the frypot during a 5-minute process called polishing. Polishing cleans the oil by trapping solid particles in the filter medium.
6. After the oil is filtered (about 5 minutes), close the drain valve and allow the fryer to refill. Let the filter pump run 10 to 12 seconds after the oil begins to bubble. Turn the filter off.
Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS diagram (page 20)
Fig. 32

Filter Pump Reset Switch 7. Lower the elements into the frypot and reinstall the basket support rack.

Page 21 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 21 · click to enlarge
Page 21
8. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not operate.) Turn the fryer ON and allow the oil to reach setpoint.

WARNING Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to seal the joint between the fry vessels. Banging fry baskets on the strip to dislodge shortening will distort the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for cleaning. 4.4 Disassembly and Reassembly of the Magnasol Filter Dissassembly 1. Grasp the frame with your thumbs on the handles at the corner of the assembly and pull outward in opposite directions to separate the frame at the corner. Continue to open the frame (it will pivot at the opposite corner) until the outer screens and grid can be removed from the frame.

2. Separate

and grid.

1. Grasp frame with thumbs on these handles and pull frame appart at corner.
2. Separate the outer screens and grid. Cleaning
1. Clean the two frame pieces, outer screens, and grid using a good quality degreaser and hot water from a spray nozzle. The groove in the seal frame pieces can be cleaned with the edge of a Scotch-Brite™ or similar cleaning pad. 2. At each scheduled boil-out, disassemble the leaf filter assembly and place in the frypot being boiled out. Follow the boil-out procedure in Section 5.1.2 of this manual.

the outer screens

Page 22 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS
Page 22 · click to enlarge
Page 22

3. Allow all filter assembly components to air dry or thoroughly dry with clean towels before reassembling. Reassembly 1. Place the two outer screens together and align their edges (see illustration on following page). 2. Insert the screens into one of the frame halves (it doesn’t matter which one). Ensure that the fitting in the bottom screen is on the opposite side of the frame from the handle. 3. Slip the grid between the screens, ensuring that the grid is centered between the edges of the screens. 4. Connect the other half of the frame at the corner opposite the handles and pivot the frame onto the free edges of the screen.

Steps 1 and 2 - Stack outer screens and insert edges into frame.

3. Insert grid between screens after screens have been positioned in frame.
4. Connect corner then pivot frame over free edges of screens.

4.5 Draining and Disposing of Waste Oil When your oil has reached the end of its usable life, drain the oil into an appropriate METAL container for transport to the disposal container. Frymaster recommends the use of the Frymaster Shortening Disposal Unit (SDU). NOTE: If using an SDU built before January 2004 the filter pan cover must be removed to allow the unit to be positioned beneath the drain. To remove the lid, lift up on the front edge and pull it straight out of the cabinet. Refer to the documentation furnished with your disposal unit for specific operating instructions. If a shortening disposal unit is not available, allow the oil to cool to 100°F (38°C), then drain the oil into a metal stockpot or similar metal container. When draining is finished, close the fryer drain valve securely.

Handle

Page 23 of the Frymaster E4 user manual — 5.1 Cleaning the Fryer
Page 23 · click to enlarge
Page 23

RE SERIES E 4 ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE

5.1 Cleaning the Fryer

Frymaster E4 — 5.1 Cleaning the Fryer diagram (page 23)
Fig. 33 · 5.1 Cleaning the Fryer
Frymaster E4 — 5.1 Cleaning the Fryer diagram (page 23)
Fig. 34 · 5.1 Cleaning the Fryer

WARNING Use a commercial-grade cleaner formulated to effectively clean and sanitize food-contact surfaces. Read the directions for use and precautionary statements before use. Particular attention must be paid to the concentration of cleaner and the length of time the cleaner remains on the food-contact surfaces. 5.1.1 Clean Inside and Outside of the Fryer Cabinet – Daily Clean inside the fryer cabinet with a dry, clean cloth. Wipe all accessible metal surfaces and components to remove accumulated oil and dust. Clean outside the fryer cabinet with a clean, damp cloth soaked with detergent. Wipe with a clean, damp cloth. 5.1.2 Clean the Built-in Filtration System – Daily

Page 24 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE
Page 24 · click to enlarge
Page 24

5.1.3 Clean the Frypot and Heating Elements- Weekly

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE diagram (page 24)
Fig. 35

DANGER Never operate the appliance with an empty frypot. The frypot must be filled to the fill line with water, oil or shortening before energizing the elements. Failure to do so will result in irreparable damage to the elements and may cause a fire. 5.1.4 Boiling Out the Frypot Before the fryer is first used, it should be boiled out to ensure that residue from the manufacturing process has been eliminated. Also, after the fryer has been in use for a period of time, a hard film of caramelized oil will form on the inside of the frypot. This film should be periodically removed by following the boil out procedure that follows. 1. Before switching the fryer(s) ON, close the frypot drain valve(s), then fill the empty frypot with a mixture of cold water and detergent. Follow instructions on detergent container when mixing. 2. Press the fryer ON/OFF switch to the ON position. On fryers equipped with solid state (analog) controllers, set the melt switch to OFF. 3. For fryers equipped with Computer Magic III.5 computers, program the computer for boil-out as described in the separate Frymaster Fryer Controllers User’s Manual.

For fryers with digital controllers, set the temperature to 195°F (91°C) as described in the separate Frymaster Fryer Controllers User’s Manual. For fryers with solid state (analog) controllers, set the temperature control knob to the lowest setting. 4. Simmer the solution for 45 minutes to one hour. Do not allow the water level to drop below the bottom oil-level line in the frypot during the boil-out operation. NOTE: For units with thermostat controllers, you must turn the fryer on and off periodically during this process to prevent the frypot from boiling over.

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE diagram (page 24)
Fig. 36

DANGER Never leave the fryer unattended during the boil-out process. If the boil-out solution boils over, turn the fryer off immediately and let the solution cool for a few minutes before resuming the process. 5. Turn the fryer ON/OFF switch(s) to the OFF position. 6. Add two gallons (7.6 liters) of water. Drain out the solution and clean the frypot(s) thoroughly.

Frymaster E4 — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE diagram (page 24)
Fig. 37
Page 25 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE
Page 25 · click to enlarge
Page 25
7. Refill the frypot(s) with clean water. Rinse the frypot(s) twice, drain and dry with a clean towel. Thoroughly remove all water from the frypot and elements before refilling the frypot with oil.
  • DANGER Remove all drops of water from the frypot before filling with oil. Failure to do so will cause spattering of hot liquid when the oil is heated to cooking temperature. 5.1.5 Clean Detachable Parts and Accessories – Weekly Wipe all detachable parts and accessories with a clean, dry cloth. Use a clean cloth saturated with detergent to remove accumulated carbonized oil on detachable parts and accessories. Rinse the parts and accessories thoroughly with clean water and wipe dry before reinstalling. 5.2 Check Calibration of Solid State (Analog) Controller Knob – Monthly NOTE: Required only on fryers equipped with a Solid State (Analog) Controller. 1. After the oil reaches operating temperature, let the heating elements cycle at least four times. 2. Insert a thermometer or pyrometer probe near the temperature-sensing probe approximately three inches (7.5 mm) deep into the oil. When the heating elements cycle on for the fourth time, the thermometer should within ± 5 ° F ( ± 2 ° C) of the temperature control knob setting. 3. If the knob requires adjustment, refer to Chapter 4 of the separate Frymaster Fryer Controllers User’s Manual furnished with your fryer. 5.3 Annual/Periodic System Inspection This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program. Frymaster recommends that this appliance be inspected at least annually by a Factory Authorized Service Technician as follows: Fryer
  • Inspect the cabinet inside and out, front and rear for excessive oil.
  • Verify that the heating element wires are in good condition and that leads have no visible fraying or insulation damage and that they are free of oil.
  • Verify that heating elements are in good condition with no carbon/caramelized oil build-up. Inspect the elements for signs of extensive dry-firing.
  • Verify that the tilt mechanism is working properly when lifting and lowering elements, and that the element wires are not binding and/or chafing.
  • Verify the heating-element amp-draw is within the allowed range as indicated on the appliance’s rating plate.
Page 26 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE
Page 26 · click to enlarge
Page 26
  • Verify that the temperature and high-limit probes are properly connected, tightened and functioning properly, and that mounting hardware and probe guards are present and properly installed.
  • Verify that component box and contactor box components (i.e. computer/controller, relays, interface boards, transformers, contactors, etc.) are in good condition and free from oil and other debris.
  • Verify that component box and contactor box wiring connections are tight and that wiring is in good condition.
  • Verify that all safety features (i.e. contactor shields, drain safety switches, reset switches, etc.) are present and functioning properly.
  • Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in serviceable condition.
  • Verify that all wiring harnesses and connections are tight and in good condition. Built-In Filtration System
  • Inspect all oil-return and drain lines for leaks and verify that all connections are tight.
  • Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.
  • Verify that all O-rings and seals (including those on the quick-disconnect fittings) are present and in good condition. Replace O-rings and seals if worn or damaged.
  • Check filtration system integrity as follows: − Verify that filter pan cover is present and properly installed. − With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify

that the pump activates and that bubbles appear in the oil of the associated frypot. − Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper

functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot. − Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to

350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all oil to return to the frypot, indicated by bubbles in the oil. Return the oil return handle to the OFF position. The frypot should have refilled in no more than 2 minutes and 30 seconds.

Page 27 of the Frymaster E4 user manual — RE SERIES E 4 ELECTRIC FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING
Page 27 · click to enlarge
Page 27

RE SERIES E 4 ELECTRIC FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING

6.1 Introduction This section provides an easy reference guide to some of the common problems that may occur during the operation of this equipment. The troubleshooting guides that follow are intended to help correct, or at least accurately diagnose, problems with this equipment. Although the chapter covers the most common problems reported, you may encounter problems that are not covered. In such instances, the Frymaster Technical Services staff will make every effort to help you identify and resolve the problem. When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through to the most complex. Never overlook the obvious – anyone can forget to plug in a cord or fail to close a valve completely. Most importantly, always try to establish a clear idea of why a problem has occurred. Part of any corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections, too. If a fuse continues to blow, find out why. Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system. Before calling a service agent or the Frymaster HOTLINE (1-800-551-8633):

  • Verify that electrical cords are plugged in and that circuit breakers are on.
  • Verify that frypot drain valves are fully closed.
Page 28 of the Frymaster E4 user manual — Problem Probable Causes Corrective Action
Page 28 · click to enlarge
Page 28

6.2 Troubleshooting 6.2.1 Controller and Heating Problems

Problem Probable Causes Corrective Action

A. Plug power cord in and verify

A. Power cord is not plugged in or

that circuit breaker is not tripped.

circuit breaker is tripped.

B. If any of the components in the

power supply system (including the transformer and interface board) fail, power will not be supplied to the controller and it will not function. Determining which component has failed is beyond the scope of operator troubleshooting. Call FASC.

activate. B. Controller or power supply

component or interface board has failed.

A. A drain safety switch prevents

the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed.

A. Drain valve is open.

B. If the circuitry in the fryer

control system cannot determine the frypot temperature, the system will not allow the element to be energized or will de-energize the element if it is already energized. If the contactor, element, or associated wiring fails, the element will not energize. Determining which specific component is malfunctioning is beyond the scope of operator troubleshooting. Call FASC.

Fryer does not heat.

B. One or more other components

have failed.

Controller won't

Page 29 of the Frymaster E4 user manual — Problem Probable Causes Corrective Action
Page 29 · click to enlarge
Page 29

Problem Probable Causes Corrective Action

This is normal for fryers equipped with CM III.5 computers, Basket Lift Timers, and Digital Controllers. The default operational mode for these controllers is for the elements to cycle on and off until the temperature in the frypot reaches 180ºF (82ºC). In CM III.5 computers, CYCL will appear in the display when in the melt-cycle mode. The purpose of the melt- cycle is to allow controlled melting of solid shortening to prevent scorching and flash fires or damage to the element. If you are not using solid shortening, the melt-cycle can be cancelled or bypassed. Refer to the separate Frymaster Fryer Controllers User's Manual for the procedure for canceling the melt- cycle for the particular controller installed on your fryer.

cycles on and off when first started.

Fryer is in melt-cycle mode.

In fryers equipped with Solid State (Analog) controllers, the melt- cycle is controlled manually by means of the rocker switch to the right of the temperature control knob. If not using solid shortening, press the rocker switch to the OFF position to turn off the melt-cycle.

This fryer is equipped with a drain safety switch that prevents the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed. Fryer heats until high limit trips with

Fryer does not heat

after filtering. Drain valve is open.

Temperature probe or controller has failed.

Turn fryer off and call FASC.

heat indicator ON.

Fryer repeatedly

Page 30 of the Frymaster E4 user manual — Problem Probable Causes Corrective Action
Page 30 · click to enlarge
Page 30

Problem Probable Causes Probable Causes Fryer heats until

Contactor or controller has failed. Call FASC.

without heat indicator ON.

Determining which component has failed is beyond the scope of operator troubleshooting. Call FASC. 6.2.2 Error Messages and Display Problems

The high limit thermostat or contactor has failed.

ON.

Problem Probable Causes Corrective Action

Verify that the drain valve is fully closed. The fryer will not function if the drain valve is not fully closed. If the drain valve is fully closed, the problem is within the latching circuitry and is beyond the scope of operator trouble shooting. Call FASC.

Open drain valve or problem with latching circuits

This in an indication of a malfunction in the temperature control circuitry, including a failure of the high limit thermostat. Shut the fryer down immediately and call FASC.

Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).

Basket lift timer display shows

This indicates a problem within the temperature measuring circuitry that is beyond the scope of operator troubleshooting. Shut the fryer down and call FASC.

Problem with the temperature measuring circuitry including the probe.

CM III.5 computers may be programmed to display in either Fahrenheit or Celsius. Refer to the separate Frymaster Fryer Controllers User's Manual for instructions on changing the display.

CM III.5 display is

in wrong temperature scale

Incorrect display option programmed.

Celsius).

Verify that the drain valve is fully closed. The fryer will not function if the drain valve is not fully closed. If the drain valve is fully closed, the problem is within the latching circuitry and is beyond the scope of operator trouble shooting. Call FASC.

CM III.5 display

Open drain valve or problem with latching circuitry.

Show 9 more labels / short text on this page
high limit trips · Fryer stops heating · with heat indicator · Basket lift timer · display shows · Basket lift timer · display shows · (Fahrenheit or · shows
Page 31 of the Frymaster E4 user manual — Problem Probable Causes Corrective Action
Page 31 · click to enlarge
Page 31

Problem Probable Causes Corrective Action

This display is normal if the fryer setpoint has been changed to a lower temperature. The display should revert to the normal four dashes when the frypot temperature cools to the setpoint. If the setpoint has not been changed, this indicates a problem with the temperature control circuitry. Turn the fryer off and call FASC.

CM III.5 display

Fryer is more than 21ºF (12ºC) above setpoint.

This in an indication of a malfunction in the temperature control circuitry, including a failure of the high limit thermostat. Shut the fryer down immediately and call FASC.

Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).

CM III.5 display

This display is normal when the fryer is first turned on and may appear for a short while if a large batch of frozen product is added to the frypot. If the display never goes out, the fryer is not heating. Look for a decimal in the LED display between digits 1 and 2. If the decimal is present, the computer is calling for heat and is functioning properly. See Fryer Does Not Heat in Control and Heating Problems (Section 6.2.1). If the decimal is not present, the computer is not calling for heat and may be malfunctioning

CM III.5 display

Frypot temperature is more than 21ºF (12ºC) below setpoint.

This indicates a problem within the temperature measuring circuitry that is beyond the scope of operator troubleshooting. Shut the fryer down and call FASC.

Problem with the temperature measuring circuitry including the probe.

CM III.5 display

The CM III.5 computer may be programmed for constant temperature display or countdown timer display. Refer to the separate Frymaster Fryer Controllers User's Manual for instructions on toggling between these display options.

CM III.5 frypot

Computer is programmed for constant temperature display.

temperature is displayed constantly.

Show 4 more labels / short text on this page
shows · shows · shows · shows
Page 32 of the Frymaster E4 user manual — Problem Probable Causes Corrective Action
Page 32 · click to enlarge
Page 32

Problem Probable Causes Corrective Action

Digital controllers are manually set to display in one temperature scale or the other. Refer to the separate Frymaster Fryer Controllers User's Manual for instructions on changing the display.

Digital controller display is in wrong

Incorrect display option selected.

Celsius).

Verify that the drain valve is fully closed. If the drain valve is fully closed, the problem is within the latching circuitry and is beyond the scope of operator trouble shooting. Call FASC.

Open drain valve or problem with latching circuits

This in an indication of a malfunction in the temperature control circuitry, including a failure of the high limit thermostat. Shut the fryer down immediately and call FASC.

Frypot temperature is more than 410°F (210°C) or, in CE countries, 395°F (202°C).

Digital controller display shows

This indicates a problem within the temperature measuring circuitry that is beyond the scope of operator troubleshooting. Shut the fryer down and call FASC.

Problem with the temperature measuring circuitry including the probe.

This in an indication of a malfunction in the temperature measuring or control circuitry, including a failure of the high limit thermostat. Determining the specific problem is beyond the scope of operator troubleshooting. Shut the fryer down immediately and call FASC.

Oil temperature above acceptable range or a problem with the temperature measuring circuitry.

trouble light ON.

Verify that the drain valve is fully closed. The fryer will not function if the drain valve is not fully closed. If the drain valve is fully closed, the problem is within the latching circuitry and is beyond the scope of operator troubleshooting. Call FASC. Solid state controller trouble light ON and

Solid state controller trouble light ON and

Open drain valve or problem with latching circuits

ON.

The temperature probe has failed. Call FASC.

OFF.

Show 9 more labels / short text on this page
temperature scale · (Fahrenheit or · Digital controller · display shows · Digital controller · display shows · Solid state controller · heating mode light · heating mode light
Page 33 of the Frymaster E4 user manual — Problem Probable Causes Corrective Action
Page 33 · click to enlarge
Page 33

6.2.3 Basket Lift Problems Problem Probable Causes Corrective Action

Apply a light coating of Lubriplate™ or similar lightweight white grease to the rod and bushings. 6.2.4 Filtration Problems

Basket lift movement is noisy,

Lack of lubrication on basket lift rods.

jerky, or erratic.

Problem Probable Causes Corrective Action

A. Verify that the power cord is

A. Power cord is not plugged in or

fully plugged in. If so, verify that circuit breaker is not tripped.

circuit breaker is tripped.

B. If the motor is too hot to touch

for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch.

B. Pump motor has overheated

causing the thermal overload switch to trip.

start.

C. Blockage in filter pump.

C. Pump blockages are usually

caused by sediment buildup in the pump due to improperly sized or installed filter paper and failure to use the crumb screen. Call FASC.

Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If the pump motor hums for a short time then stops, the probable cause is blockage of the pump itself.

Blockage in filter pan suction tube.

The blockage may be caused by sediment buildup or, if solid shortening is used, solidified shortening in the tube. Use a thin, flexible wire to remove the blockage. If the blockage cannot be removed, call FASC.

but oil does not return to frypot and

Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If bubbling oil occurs, there is a blockage in the filter pan suction tube.

there is no bubbling

oil.

Filter pump won't · Filter pump runs

Page 34 of the Frymaster E4 user manual — Problem Probable Causes Corrective Action
Page 34 · click to enlarge
Page 34

Problem Probable Causes Corrective Action

A. If using filter paper or pad

configuration, verify that filter screen is in bottom of pan with paper or pad on top of screen.

Verify that O-rings are present and in good condition on filter pan connection fitting.

A. Improperly installed filter pan

components.

If using Magnasol filter assembly, verify that O-ring is present and in good condition on filter screen fitting.

Filter pump runs, but oil return is very

oil occurs.

B. In order to properly filter, the

oil or shortening should be at or near 350ºF (177ºC). At temperatures lower than this, the oil becomes too thick to pass through the filter medium easily, resulting in much slower oil return and eventual overheating of the filter pump motor. Make sure oil is at or near frying temperature before draining oil into filter pan.

B. Attempting to filter with oil that

is not hot enough.

slow and bubbling

Page 35 of the Frymaster E4 user manual — THIS PAGE INTENTIONALLY LEFT BLANK
Page 35 · click to enlarge
Page 35

THIS PAGE INTENTIONALLY LEFT BLANK

Page 36 of the Frymaster E4 user manual — 819-6149 PRINTED IN THE UNITED STATES SERVICE HOTLINE
Page 36 · click to enlarge
Page 36
Frymaster E4 — 819-6149 PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 36)
Fig. 38
Frymaster E4 — 819-6149 PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 36)
Fig. 39

Frymaster, 8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 (Tech Support) 1-318-219-7135

819-6149 PRINTED IN THE UNITED STATES SERVICE HOTLINE

1-800-551-8633 FEB 09

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Controller won't activate.A. Power cord is not plugged in or circuit breaker is tripped.A. Plug power cord in and verify that circuit breaker is not tripped. p.28
Controller won't activate.B. Controller or power supply component or interface board has failed.B. If any of the components in the power supply system (including the transformer and interface board) fail, power will not be supplied to the controller and it will not function. Determining which component has failed is beyond the scope of operator troubleshooting. Call FASC. p.28
Fryer does not heat.A. Drain valve is open.A. A drain safety switch prevents the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed. p.28
Fryer does not heat.B. One or more other components have failed.B. If the circuitry in the fryer control system cannot determine the frypot temperature, the system will not allow the element to be energized or will de-energize the element if it is already energized. If the contactor, element, or associated wiring fails, the element will not energize. Determining which specific component is malfunctioning is beyond the scope of operator troubleshooting. Call FASC. p.28
Fryer repeatedly cycles on and off when first started.Fryer is in melt-cycle mode.This is normal for fryers equipped with CM III.5 computers, Basket Lift Timers, and Digital Controllers. The default operational mode for these controllers is for the elements to cycle on and off until the temperature in the frypot reaches 180ºF (82ºC). In CM III.5 computers, CYCL will appear in the display when in the melt-cycle mode. The purpose of the melt- cycle is to allow controlled melting of solid shortening to prevent scorching and flash fires or damage to the element. If you are not using solid shortening, the melt-cycle can be cancelled or bypassed. Refer to the separate Frymaster Fryer Controllers User's Manual for the procedure for canceling the melt- cycle for the particular controller installed on your fryer. In fryers equipped with Solid State (Analog) controllers, the melt- cycle is controlled manually by means of the rocker switch to the right of the temperature control knob. If not using solid shortening, press the rocker switch to the OFF position to turn off the melt-cycle. p.29
Fryer does not heat after filtering.Drain valve is open.This fryer is equipped with a drain safety switch that prevents the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed. p.29
Fryer heats until high limit trips with heat indicator ON.Temperature probe or controller has failed.Turn fryer off and call FASC. p.29
Fryer heats until high limit trips without heat indicator ON.Contactor or controller has failed. p.30
Fryer stops heating with heat indicator ON.The high limit thermostat or contactor has failed. p.30
Basket lift timer display shows .Open drain valve or problem with latching circuitsVerify that the drain valve is fully closed. The fryer will not function if the drain valve is not fully closed. If the drain valve is fully closed, the problem is within the latching circuitry and is beyond the scope of operator trouble shooting. Call FASC. p.30
Basket lift timer display shows .Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).This in an indication of a malfunction in the temperature control circuitry, including a failure of the high limit thermostat. Shut the fryer down immediately and call FASC. p.30
Basket lift timer display shows .Problem with the temperature measuring circuitry including the probe.This indicates a problem within the temperature measuring circuitry that is beyond the scope of operator troubleshooting. Shut the fryer down and call FASC. p.30
CM III.5 display is in wrong temperature scale (Fahrenheit or Celsius).Incorrect display option programmed.CM III.5 computers may be programmed to display in either Fahrenheit or Celsius. Refer to the separate Frymaster Fryer Controllers User's Manual for instructions on changing the display. p.30
CM III.5 display shows .Open drain valve or problem with latching circuitry.Verify that the drain valve is fully closed. The fryer will not function if the drain valve is not fully closed. If the drain valve is fully closed, the problem is within the latching circuitry and is beyond the scope of operator trouble shooting. Call FASC. p.30
CM III.5 display shows .Fryer is more than 21ºF (12ºC) above setpoint.This display is normal if the fryer setpoint has been changed to a lower temperature. The display should revert to the normal four dashes when the frypot temperature cools to the setpoint. If the setpoint has not been changed, this indicates a problem with the temperature control circuitry. Turn the fryer off and call FASC. p.31
CM III.5 display shows .Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).This in an indication of a malfunction in the temperature control circuitry, including a failure of the high limit thermostat. Shut the fryer down immediately and call FASC. p.31
CM III.5 display shows .Frypot temperature is more than 21ºF (12ºC) below setpoint.This display is normal when the fryer is first turned on and may appear for a short while if a large batch of frozen product is added to the frypot. If the display never goes out, the fryer is not heating. Look for a decimal in the LED display between digits 1 and 2. If the decimal is present, the computer is calling for heat and is functioning properly. See Fryer Does Not Heat in Control and Heating Problems (Section 6.2.1). If the decimal is not present, the computer is not calling for heat and may be malfunctioning p.31
CM III.5 display shows .Problem with the temperature measuring circuitry including the probe.This indicates a problem within the temperature measuring circuitry that is beyond the scope of operator troubleshooting. Shut the fryer down and call FASC. p.31
CM III.5 frypot temperature is displayed constantly.Computer is programmed for constant temperature display.The CM III.5 computer may be programmed for constant temperature display or countdown timer display. Refer to the separate Frymaster Fryer Controllers User's Manual for instructions on toggling between these display options. p.31
Digital controller display is in wrong temperature scale (Fahrenheit or Celsius).Incorrect display option selected.Digital controllers are manually set to display in one temperature scale or the other. Refer to the separate Frymaster Fryer Controllers User's Manual for instructions on changing the display. p.32
Digital controller display shows .Open drain valve or problem with latching circuitsVerify that the drain valve is fully closed. If the drain valve is fully closed, the problem is within the latching circuitry and is beyond the scope of operator trouble shooting. Call FASC. p.32
Digital controller display shows .Frypot temperature is more than 410°F (210°C) or, in CE countries, 395°F (202°C).This in an indication of a malfunction in the temperature control circuitry, including a failure of the high limit thermostat. Shut the fryer down immediately and call FASC. p.32
Digital controller display shows .Problem with the temperature measuring circuitry including the probe.This indicates a problem within the temperature measuring circuitry that is beyond the scope of operator troubleshooting. Shut the fryer down and call FASC. p.32
Solid state controller trouble light ON.Oil temperature above acceptable range or a problem with the temperature measuring circuitry.This in an indication of a malfunction in the temperature measuring or control circuitry, including a failure of the high limit thermostat. Determining the specific problem is beyond the scope of operator troubleshooting. Shut the fryer down immediately and call FASC. p.32
Solid state controller trouble light ON and heating mode light ON.Open drain valve or problem with latching circuitsVerify that the drain valve is fully closed. The fryer will not function if the drain valve is not fully closed. If the drain valve is fully closed, the problem is within the latching circuitry and is beyond the scope of operator troubleshooting. Call FASC. p.32
Solid state controller trouble light ON and heating mode light OFF.The temperature probe has failed.Call FASC. p.32
Basket lift movement is noisy, jerky, or erratic.Lack of lubrication on basket lift rods.Apply a light coating of Lubriplate™ or similar lightweight white grease to the rod and bushings. p.33
Filter pump won't start.A. Power cord is not plugged in or circuit breaker is tripped.A. Verify that the power cord is fully plugged in. If so, verify that circuit breaker is not tripped. p.33
Filter pump won't start.B. Pump motor has overheated causing the thermal overload switch to trip.B. If the motor is too hot to touch for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch. p.33
Filter pump won't start.C. Blockage in filter pump. Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If the pump motor hums for a short time then stops, the probable cause is blockage of the pump itself.C. Pump blockages are usually caused by sediment buildup in the pump due to improperly sized or installed filter paper and failure to use the crumb screen. Call FASC. p.33
Filter pump runs but oil does not return to frypot and there is no bubbling oil.Blockage in filter pan suction tube. Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If bubbling oil occurs, there is a blockage in the filter pan suction tube.The blockage may be caused by sediment buildup or, if solid shortening is used, solidified shortening in the tube. Use a thin, flexible wire to remove the blockage. If the blockage cannot be removed, call FASC. p.33
Filter pump runs, but oil return is very slow and bubbling oil occurs.A. Improperly installed filter pan components.A. If using filter paper or pad configuration, verify that filter screen is in bottom of pan with paper or pad on top of screen. Verify that O-rings are present and in good condition on filter pan connection fitting. If using Magnasol filter assembly, verify that O-ring is present and in good condition on filter screen fitting. p.34
Filter pump runs, but oil return is very slow and bubbling oil occurs.B. Attempting to filter with oil that is not hot enough.B. In order to properly filter, the oil or shortening should be at or near 350ºF (177ºC). At temperatures lower than this, the oil becomes too thick to pass through the filter medium easily, resulting in much slower oil return and eventual overheating of the filter pump motor. Make sure oil is at or near frying temperature before draining oil into filter pan. p.34

Ask about the Frymaster E4

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster E4

Be the first to ask — other owners or our team will answer.

Original document

Frymaster E4 manual PDF

36 pages·1.1 MB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…