EN
Frymaster logo
Official user manual

Frymaster CF

54 pages·4 MB·Fryer·PDF·ENDEFRITNLJA
Frymaster CF
Table of Contents 41 sections Master Jet Series Atmospheric Gas Fryers Installation and use guide · SERIES J1C, 35, 45 & CF · 1-800-551-8633 NOVEMBER 2003 PRINTED AT · Telephone permanence 24 hours a day · … ShowHide
Page 1 of the Frymaster CF user manual — 1-800-551-8633 NOVEMBER 2003 PRINTED AT
Page 1 · click to enlarge
Page 1
Frymaster CF — Master Jet Series Atmospheric Gas Fryers Installation and use guide diagram (page 1)
Fig. 1 · Master Jet Series Atmospheric Gas Fryers Installatio…

Master Jet Series Atmospheric Gas Fryers Installation and use guide

Frymaster CF — Master Jet Series Atmospheric Gas Fryers Installation and use guide diagram (page 1)
Fig. 2 · Master Jet Series Atmospheric Gas Fryers Installatio…
Frymaster CF — Master Jet Series Atmospheric Gas Fryers Installation and use guide diagram (page 1)
Fig. 3 · Master Jet Series Atmospheric Gas Fryers Installatio…
Frymaster CF — Master Jet Series Atmospheric Gas Fryers Installation and use guide diagram (page 1)
Fig. 4 · Master Jet Series Atmospheric Gas Fryers Installatio…
Frymaster CF — Master Jet Series Atmospheric Gas Fryers Installation and use guide diagram (page 1)
Fig. 5 · Master Jet Series Atmospheric Gas Fryers Installatio…

SERIES J1C, 35, 45 & CF

Frymaster, a member of the Commercial Food Equipment Service Association, recommends the use of CFESA certified technicians.

1-800-551-8633 NOVEMBER 2003 PRINTED AT

Telephone permanence 24 hours a day

UNITED STATES

*8196019*

Page 2 of the Frymaster CF user manual — CANADA
Page 2 · click to enlarge
Page 2

NOTICE This device is intended for professionals only and must be used by staff only

qualified. Installation, maintenance and repairs must be entrusted to an approved VAS centre

Frymaster or another qualified professional. Any installation, maintenance or repair by unqualified personnel may cancel the manufacturer's warranty. For the definition of "staff"

"The quality of the work is a key element in this manual.

NOTICE This equipment shall be installed in accordance with the appropriate local and national codes of the country and/or

region of installation. Refer to the National CODE REQUIREMENTS in Chapter 2 of this report.

Manual.

NOTICE TO CLIENTS IN THE UNITED STATES This equipment must be installed in accordance with the standard plumbing code of Building Officials and Code

Administrators International, Inc. (BOCA) and FDA Food Service Sanitation Manual (U.S.

Food and Drug Administration).

NOTICE The drawings and photos used in this manual are intended to illustrate the procedures for use, cleaning and technical and may not exactly match on-site usage procedures

issued by the management.

ADVICE TO CUSTOMERS USING COMPUTER-EQUIPPED DEVICES

UNITED STATES

This device complies with Part 15 of the FCC regulations. The operation of the device is subject to two conditions: 1) This device will not cause harmful interference and 2) this apparatus shall accept any received interference, including interference that may result in undesirable functioning. Although this device is listed as Class A, it has shown that it can comply with the class B limits.

CANADA

This digital apparatus does not emit any radioelectric noise exceeding the Class A and B limits prescribed in NMB-003 issued by the Minister of Communcations of Canada.

instructions for installation, use and maintenance before installing or doing

maintenance on this equipment. Only qualified maintenance personnel have the right to convert this

apparatus for the use of a gas other than that for which it was originally configured.

A vacuum hood. Any questions? Call Dean's Hotline at 1-800-551-8633.

Page 3 of the Frymaster CF user manual — KEEP AND STORE THIS MANUAL IN A SAFE PLACE TO BE ABLE TO
Page 3 · click to enlarge
Page 3

Single feet fryers shall be stabilized by installing anchor straps. All fryers equipped with castors shall be stabilized by installing restraint chains. If

you use a gas hose, you need to connect an additional holding cable at any time

when you use the fryer.

If you slide or come into contact with hot oil, you will be in serious injury.

Other aircraft.

the gas supplier.

a flame retardant container at the end of frying operations. Some food particles can burn

spontaneously if they soak in certain vegetable fats.

for a good fit and should only be removed for cleaning.

NOTICE IF, DURING THE WARRANTY PERIOD, A CUSTOMER USES PART OF THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RE-AMENDED PIECE PURCHASED DIRECTLY FROM

OF THE APPROVED FRYMASTER/DEAN OR SAV CENTRES AND/OR THAT THE PART USED IS

THIS GUARANTEE WILL BE CANCELLED. THE OTHER, FRYMASTER/DEAN AND ITS SUBSIDIARIES CANNOT BE HELD LIABLE FOR ALL CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE

CUSTOMER RESULTING DIRECTLY OR INDIRECTLY, IN WHOLE OR PART, FROM THE INSTALLATION

ANY PARTS AND/OR COMPONENTS RECEIVED FROM AN UNAPPROVED SAV CENTRE.

KEEP AND STORE THIS MANUAL IN A SAFE PLACE TO BE ABLE TO

REFER TO IT LATER.

Page 4 of the Frymaster CF user manual — Table of Contents
Page 4 · Contents
Contents

Contents

Page 5 of the Frymaster CF user manual — CHAPTER 1: INTRODUCTION
Page 5 · click to enlarge
Page 5

CHAPTER 1: INTRODUCTION

1.1 Applicability and validity All Master Jet atmospheric gas fryers have been approved by the European Union for sale and installation in the following EU countries: AT, BE, DE, DK, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE. This manual is only applicable and valid for all Master Jet gas fryers sold in French-speaking countries, including those of the European Union. In the event of a conflict between instructions and information in this manual and local and national codes in force in the country where equipment is installed, installation and use shall comply with these codes as a matter of priority. This device is for professional use and only needs to be used by qualified personnel, as described in section 1.7. 1.2 Control of parts and repairs To help you as quickly as possible, the VAS centre or Frymaster Technical Service will ask for some information about your equipment. Most of this information is printed on a nameplate behind the fryer door. Place your parts orders directly with your after-sales service centre or distributor. The fryers are provided with the list of Frymaster SAV centers. If you do not have access to this list, contact Frymaster Technical Service at 1-800-551-8633 or 1-318-865-1711. You will need to provide the following information in order to order parts:

Model Number: Serial Number: Type of gas or voltage: Part Number: Quantity Required: Your Service Centre will provide you with the necessary information regarding any repairs. You can also obtain this information by contacting the Frymaster Technical Service at 1-800-551-8633 (US/Canada) or 1-318-865-1711 (worldwide). When requesting reparation, be prepared to provide the following information:

Model Number: Serial Number: Type of gas: In addition to the model number, serial number and type of gas, be prepared to describe the nature of the problem and provide any information that may be useful in resolving the issue.

Page 6 of the Frymaster CF user manual — CHAPTER 1: INTRODUCTION
Page 6 · click to enlarge
Page 6

CHAPTER 1: INTRODUCTION

1.3 Safety instructions Before using this device, read the instructions in this manual carefully. Your fryer is equipped with two automatic security:

  • The detection of a high temperature shuts off the gas coming to burners in case of failure of the control thermostat.
  • A safety switch integrated with the fryer drain valve with built-in filtering system prevents burners from being switched on with an open discharge tap, even partially. Throughout this manual, you will find annotations framed in a double border similar to those shown below.
Frymaster CF — CHAPTER 1: INTRODUCTION diagram (page 6)
Fig. 6

DANGER The boxes of the DANGAR box contain information on actions or conditions which risk of causing or producing injury and which can cause damage to your system and/or malfunction. 1.4 Information on the European Union The European Union (EU) has defined certain specific standards for such equipment. Whenever there is a difference between EU and non-EU standards, the relevant information or instructions shall be identified by means of grey boxes similar to that given below.

Frymaster CF — CHAPTER 1: INTRODUCTION diagram (page 6)
Fig. 7
Page 7 of the Frymaster CF user manual — MJ2CFEMBLSC
Page 7 · click to enlarge
Page 7

CHAPTER 1: INTRODUCTION

1.5 Description of the equipment Master Jet atmospheric gas fryers are designed for general frying applications (model J1C, MJ35) and large volume (model MJ45, MjCF). 1.5.1 Options designation codes Many options are available for Master Jet atmospheric gas fryers. When the fryers are equipped with options, suffixes are added to the name of the model to identify these options. The position of the identification letter is a factor in the identified option. Below you will find an example of typical options for Master Jet fryers. The fryer configuration is revealed by codes that identify the model name and various options: Model designation codes: J: Fry millivolts on a worktop. MJ : Master Jet (all models except J1C; filtering system not included in the MJ designation codes). FM : Filter Magic filter system in separate cabinet (does not apply to the J1C series). F : The fryer is configured for connection to an existing deep-fry or filter system (does not apply to the J1C series). X : Export-flict (generally specifies the country designation codes for export). Refrigerant tank designation codes: 1: Simple, funny. 2: Two fryer battery. 3: Three-fry battery. 4: Four-fry battery. 5: Five fryer battery. 6: Six-fried battery.

Specific model designation codes.

Model designation codes.

Series designation codes.

Indicates the material used to build the frying basin and cabinet.

MJ2CFEMBLSC

Codes for designation of frying ponds.

of the fusion cycle

automatic baskets.

(option).

Designation code · Indicates presence

Page 8 of the Frymaster CF user manual — CHAPTER 1: INTRODUCTION
Page 8 · click to enlarge
Page 8

CHAPTER 1: INTRODUCTION

1.5.1 Options Designation Codes (cont'd) Model Specific Designation Code: G: Control of thermostat on front panel (MJ35 series only). E : Requires external power supply (does not apply to J1C and MJ35 series). V : Economic Friesher (economic MJ35 series for export). No designation code here: Standard control behind the front panel (applies exclusively to MJ35 series). Merger Cycle Designation Code (Option): M: Optional fusion cycle control on the front panel (does not apply to J1C and MJ35 series). No designation code here: Option Fusion cycle not included. Automatic basket designation codes: BL: Frymaker equipped with an automatic motorized basket (does not apply to the J1C and MJCF series). No text in this position: No automatic basket. Codes for designation of frying basin and cabinet materials: HC: Stainless steel cabinet, door and cupboard. SD : Stainless steel tray and door; painted wardrobe. SE : Stainless steel tray, door, cabinet and sides. SP : Stainless steel tank; door and cabinet painted. ST : Cold-rolled steel tank; painted door and cabinet. SX : Cold-rolled steel tank; stainless steel door and painted cabinet. 1.5.2 Applications according to the model The J1C series gas fryers are worktop fryer systems designed for restricted spaces and general frying. The capacity of the J1C frying basin is 6.8-9 kg. The MJ35 series fryers are self-contained frying machines designed for all-purpose frying. The capacity of the MJ35 frying basin is 13.6 to 18.1 kg. The MJ45 series fryers are self-contained frying machines designed for large volume frying. The capacity of the MJ45 frying basin is 18.1 to 22.7 kg. The MJCF series fryers are self-contained frying machines designed for large volume frying, especially chicken, fish and other breaded products. The capacity of the MJCF frying basin is 27.2 to 36.2 kg.

Page 9 of the Frymaster CF user manual — CHAPTER 1: INTRODUCTION
Page 9 · click to enlarge
Page 9

CHAPTER 1: INTRODUCTION

1.5.2 Model Applications (cont'd) All models, except J1C series fryers, can be equipped with an optional integrated filter system. All models, except J1C and MJ35 series fryers, can be configured for power supplies ranging from 120 to 240 V (~). All models are lidless and have a hand-sized opening giving access to the deep cold zone, which facilitates cleaning of stainless steel frying basin. Fries equipped with an integrated filtering system are shipped fully assembled. Fries without integrated filtering system require optional feet or castors at the point of use (J1C series not available with wheels). All the fryers are shipped with a standard pack of accessories. Each fryer is set, tested and inspected at the factory before it can be put into storage for shipment. The frying basins are made of cold-rolled steel or thick and welded stainless steel. Heating is provided by a set of burners with multiple gas jets, which are concentrated on ceramic targets located around the base of the frying basin. All burners can be configured for natural gas, propane or manufactured gas. The frying basin is drained by means of a hand ball valve. Master Jet atmospheric gas fryers are equipped with a thermostatic probe for precise temperature regulation. The probe is located at the centre of the frying basin for a quick response to load variations in order to provide the most accurate temperature measurement. Master Jet atmospheric gas fryers can be equipped with an optional fusion cycle function (not applicable to the J1C and MJ35 series), which alternates between ignition and burner extinguishing at a predefined frequency. The melting cycle function prevents overcooking and un even heating of the frying basin when using solid vegetable fat. The controls of the Master Jet atmospheric gas fryers vary from one model to another. Optional controls may include thermostat commands, semi-conductor (analog) controllers, digital controllers or Computer Magic III.5. Not all models are available with any controllers offered as an option. Each type is discussed in detail in the manual entitled Frymaster fryer controllers - User Manual, supplied separately with your equipment. 1.6 Installation, use and maintenance personnel The instructions for use of Frymaster equipment have been prepared for exclusive use by qualified and/or authorized personnel, as described in Section 1.7. The entire installation and maintenance of Frymaster equipment shall be entrusted to qualified, certified, licensed and/or authorized plant or maintenance personnel as described in Section 1.7.

Page 10 of the Frymaster CF user manual — FRYMASTER L.L.C.  DOES NOT ASSUME ANY RESPONSIBILITY FOR
Page 10 · click to enlarge
Page 10

CHAPTER 1: INTRODUCTION

1.7 QUALIFIED AND/OR AUTHORIZED OPERATORS Definitions

The so-called "qualified or authorized" operators are those who have read the information in this manual carefully and become familiar with equipment functions or have had experience with instructions for use of materials covered by this manual.

QUALIFIED INSTALLATION STAFF The qualified installation staff consists of persons, firms, undertakings or companies who either in person or through a representative are engaged in and responsible for the installation of gas appliances. Skilled personnel must have experience in such work, be familiar with all gas precautions and comply with all requirements of existing national and local codes. QUALIFIED MAINTENANCE STAFF The qualified maintenance staff includes those who are familiar with Frymaster equipment and have been authorized by FryMaster, L.L.C. to perform maintenance on Frymaster hardware. All authorized maintenance personnel shall be equipped with a complete set of maintenance manuals and parts, and have in stock a minimum prescribed number of components for Frymaster devices. The list of Frymaster approved VAS centres is provided with the factory-consigned fryer. Use a qualified maintenance staff under penalty of cancellation of the Frymaster warranty for your equipment. 1.8 Procedure for claiming damage during transport Your Frymaster equipment was thoroughly inspected and packed before it came out of the factory. The carrier assumes full responsibility for a delivery in good port and condition upon acceptance of the equipment. What to do if your equipment arrives damaged: 1. Immediately submit a claim for damages, regardless of the extent of damage. 2. Inspect the equipment to check for no visible signs of loss or damage and ensure that the damage is reported on the transport invoice or delivery receipt, which must have been signed by the deliverer. 3. Unobvious loss or damage which were not visible before the unpacking of equipment shall be noted and reported immediately the carrier from their detection. A claim for non-obvious damages must be submitted within 15 days of the date of delivery. Keep the shipping carton for inspection.

FRYMASTER L.L.C. DOES NOT ASSUME ANY RESPONSIBILITY FOR

DAMAGE OR LOSS INCURRED DURING THE

TRANSPORT.

Page 11 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 11 · click to enlarge
Page 11

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.1 General Installation Requirements A qualified, licensed and/or authorized installation or maintenance staff as defined in section 1.7 of this manual shall perform the entire Frymaster installation and maintenance. The conversion of this apparatus from one type of gas to another shall be carried out only by qualified, licensed and/or authorized installation or maintenance personnel as defined in Section 1.7 of that manual. Follow this instruction regarding installation, conversion to another type of gas or other maintenance on the device, otherwise you may cancel Frymaster's warranty and damage equipment or injure staff. In the event of a conflict between instructions and information in this manual and local and national codes and regulations applicable in the country where equipment is installed, installation and use shall comply with these codes and rules as a matter of priority.

d) hot vegetable oil or grease next to a naked flame of any kind,

includes a grill and gas stove flame. When delivered, thoroughly inspect the fryer to ensure that it does not show visible or non-obvious signs of damage. (See Procedure for claiming damage during transport in Chapter 1.)

damage and injury. For removable installations, you must use

optional castors. Any questions? Call 1-800-551-8633. A PROPER INSTALLATION IS ESSENTIAL TO THE EFFICIENT AND TROUBLE-FREE OPERATION OF YOUR FRYER. ANY UNAUTHORIZED ALTERATION OF THIS EQUIPMENT WILL CANCEL THE FRYMASTER WARRANTY. When delivered, thoroughly inspect the fryer to ensure that it does not show visible or non-obvious signs of damage. (See Procedure for claiming damage during transport in Chapter 1.)

Page 12 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 12 · click to enlarge
Page 12

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.1 General installation requirements (cont'd) DEGAGMENT AND VENTILATION

Dean telephone at 1-800-551-8633.

unacceptable levels of substances harmful to the health of personnel in

the room where it is installed.

The fryer(s) shall be installed with a clearance of 150 mm on both sides and at the rear when fitted next to a fuel construction; no release is required during installation adjacent to non-combustible construction. A minimum clearance of 600 mm shall be provided on the front of the fryer. One of the most important considerations for efficient operation of a fryer is ventilation. Make sure that the fryer is installed so that combustion products are effectively eliminated and that the kitchen ventilation system does not produce air currents which interfere with burner operation. The smoke duct opening shall not be placed near the intake of the exhaust fan and the fryer must never see its smoke conduit extended in a "fireplace" manner. An extension smoke duct will change the combustion characteristics of the fryer, resulting in a longer recovery time. Very often, it causes a delay in ignition. To provide the air circulation necessary for proper combustion and operation of burners, areas adjacent to the front, sides and back of the fryer must be clear. The fryers shall be installed in a place with adequate air supply and ventilation. Adequate distances shall be maintained from the outlet of the smoke duct in the fryer to the lower edge of the ventilation filter series. Filters must be installed at 45o. Place a perforated tray under the lowest edge of the filter. For a facility in the United States, NFPA No. 96 states that "a minimum distance of 18 inches (450 mm) shall be maintained between the outlet of the smoke duct and the lower edge of the grease filter. » Frymaster recommends a minimum distance of 600 mm from the smoke duct outlet to the bottom edge of the filter when the apparatus consumes more than 120,000 BTU per hour. Information on the construction and installation of vacuum hoods is provided in NFPA, cited above. A copy of the standard is available from the National Fire Protection Association, Battery March Park, Quincy, MA 02269.

Page 13 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 13 · click to enlarge
Page 13

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.1 General installation requirements (cont'd) NATIONAL CODE REQUIREMENTS The type of gas for which the fryer is configured shall be stamped on the nameplate attached behind the door of the frying machine. Connect a "NAT" marked fryer to natural gas only, "PRO" to propane and "MFG" to manufactured gas. The installation shall be carried out with a gas connector conforming to national and local codes and, where appropriate, EC codes. Demountable fittings, if any, shall also conform to national, local and where appropriate EC codes. ELECTRIC GROUNDING REQUIREMENTS All electrical appliances shall be grounded in accordance with all applicable national and local codes and, where appropriate, EC codes. A diagram of the wiring is behind the fryer door. For correct voltages, refer to the plate of nominal values behind the fryer door.

Remove or bypass the earthing blade from this sheet!

Power outage. CONFORMITY The user is advised that any modification to Frymaster computers not expressly approved by the party responsible for compliance may cancel the operator's use authorization. Frymaster computers were tested and found to be in compliance with the limits of a Class A digital device under Part 15 of FCC rules. Even if they are listed as belonging to Class A, they have shown that they can comply with the class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operating in a commercial environment. This equipment produces, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual it may cause interference harmful to radio communications. The operation of the equipment in a residential area will likely cause harmful interference, in which case users will have to correct these interferences at their own expense.

Page 14 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 14 · click to enlarge
Page 14

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.1 General installation requirements (cont'd) FSC CONFORMITY (SUITE) If necessary, the operator should consult with a dealer or competent radio/TV technician for any additional suggestions.

The user will find useful the booklet "How to Identify and Resolve Radio-TV Interference Problems". It was prepared by the Federal Communications Commission and is available from the U.S. Government Printing Office, Washington DC 20402, Stock No. 004-000-00345-4. 2.2. Installation of wheels or feet

Depending on the configuration ordered, the fryer can be shipped without wheels or feet installed. If the wheels or feet are installed, you can ignore this section and move to Section 2.3, Preparations before connection. If the fryer requires rollers or feet to be installed, install them in accordance with instructions provided in your accessory package. 2.3. Preparations before connection

complete each step of this section. Once the fryer is placed under the extractor hood of the deep-fried station, make sure that the following operations have been performed: 1. It is necessary to limit the movement of fryers without depending on gas pipe connections. If you use a gas hose, you must connect at any time a holding cable when using the fryer. The holding cable and installation instructions are packed with the hose in the accessory box that was shipped with the fryer. 2. Simple fryers shall be stabilized by installing restraint chains (wheel-drivers) or anchor straps (foot-operated trimmers). Follow the instructions sent with wheels and feet to properly install chains or straps.

Page 15 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 15 · click to enlarge
Page 15

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.3 Preparations before connection (cont'd)

Fuel materials. Slice the friers with feet, unscrew them at 2.5 cm height, before adjusting them so that the fryer does not move and is to the right height under the extractor hood. Frymaster recommends a minimum distance of 600 mm from the smoke duct outlet to the lower edge of the filter when it consumes more than 120,000 BTU per hour. Fries equipped with castors do not have an integrated upgrade device. The floor on which the fryers are installed shall be uniformly flat. 4. Test the electric system of the fryer:

a. Plug the electric cord(s) of the fryer(s), onto an electrical outlet.

b. Place the power switch on position ON.

  • On fryers equipped with a thermostat, make sure that the power and heating lights are lit.
  • On computer fryers or digital displays, make sure that the display indicates

c. Place the power switch on position OFF. Make sure the power and output lights are

heating shut down or the display is empty. 5. Refer to the signal plate behind the fryer door for a check on whether the burner of the frying machine is configured for the correct type of gas before connecting the demountable connector or hose from the fry to the gas network.

Page 16 of the Frymaster CF user manual — LP
Page 16 · click to enlarge
Page 16

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.3 Preparations before connection (cont'd) 6. Ensure that the minimum and maximum gas network pressures for the type of gases to be used are in accordance with the attached tables.

Table 1EC gas inlet pressure standard

MJ35/J2X CE MJ45 CE MJCF/J65 CE

Gas type G20 G25 G31 G20G25 G 31 G20

(mbar)1 20 20-25 37-50 20 20-25 37-50 20 20-25 37-50

1,05 1,70 1,70 Number of holes

0,95 1,40 1,40 0,86 1,40

d-hole 9 9 9 18 18 18 21 21 21

9 13,5 22,5 7,5 10 20,6 7,5 10 14,9

2,50 3,06 1,51 3,10 3,58 1,80 3,62 4,18 2,35

1(mbar) = 10.2 mm CE

Table 2: Non-EC Standard

for gas inlet pressures

6" water column 1.49 kPa 14.93 mbar

14" water column 3.48 kPa 34.84 mbar

14" water column 3.48 kPa 34.84 mbar 7. On fryers equipped with an integrated filtering system and/or automatic baskets, plug the electrical cords into a power outlet behind the deep fryer.

11" water column 2.74 kPa 27.37 mbar

LP

Show 10 more labels / short text on this page
Model · Pressure · 1,40 · Diameter · Pressure (rolling · burners) · Airflow · (m3/H) · Gases Minimum Maximum · Natural
Page 17 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 17 · click to enlarge
Page 17

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.4. Connection to the gas network

Frymaster CF — CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 17)
Fig. 8

eliminate all foreign materials. The presence of foreign materials in the burner or gas controls will compromise system operation and

It could make him dangerous.

Frymaster CF — CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 17)
Fig. 9

gas pipeline if test pressure is greater than 1⁄2 PSIG (3.45 kPa) to avoid

damage the gas tubes and valves of the fryer. The CF series has been marked with the EC mark for countries and categories of gases listed in Table 3 below.

Frymaster CF — CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 17)
Fig. 10

The diameter of the gas line used for installation is very important. If it is too narrow, the gas pressure at the burner ramp will be low. This may slow the recovery and delay ignition. The network gas inlet line shall be at least 38 mm diameter. Refer to the table on next page for minimum diameters of connecting pipes.

Page 18 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 18 · click to enlarge
Page 18

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.4. Gas connection (cont'd)

Gas connections diameters (minimum diameter of the finish pipe: 1 1/2" (38 mm))

Unit 2 - 3 units 4 or more*

Natural 3/4" (19 mm) 1" (25 mm) 1/4/4" (33 mm)

Propane 1/2" (13 mm) 3/4" (19 mm) 1" (25 mm)

Manufactured 1" (25 mm) 1-1/4" (33 mm) 1-2" (38 mm)

* For distances of more than 6 m and/or 4 connections or elbows, increase the connection by a pipe diameter.

EC Standard EC regulations require a combustion air intake of 2 m3/h per kW per fryer. (For the nominal value of kW, refer to the door-mounted design plate.)

1. Connect the quick-disassembly hose to the fast-removal connector of the fryer, under the front of the deep fryer and to the gas network line in the building. NOTE: Some fryers are configured for a rigid connection to the gas network line. These devices connect to the gas network from behind.

If you use a threaded fat, only use very small amounts on male fillets. Use a thread grease that is not affected by the chemical action of LPG gases (the Loctite PST567 thread fat is one). Do NOT apply grease to the first two fillets or stop burner openings and safety valve. 2. Open the gas inlet valve of the fryer and make sure that pipes and fittings do not leak. Use a soap and water solution to do this.

Model one · Gas

Page 19 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 19 · click to enlarge
Page 19

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.4. Gas connection (cont'd)

Frymaster CF — CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 19)
Fig. 11

used and all connections must be tested with soapy water solution

Never use matches, candles or other ignition sources to check leaks. If you detect gas odours, cut the gas inlet by closing the tap.

network gas and contact immediately the local gas company or a

Approved maintenance. 3. Close the fryer drain valve and fill the basin with water frying and boiling solution to the lower LEVEL OIL marker at the back of the pool. Turn on the fryer and perform boiling procedures described under "Ignition Instructions" and "Boiler Procedure", in Chapter 3 of this manual.

Frymaster CF — CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 19)
Fig. 12

cause a fire. Always make sure that melted vegetable fat, oil from the

cooking or water is in the frying basin before turning on the appliance. 4. At that time, you must have the pressure at the burner ramp checked by a local gas company or an approved maintenance agent. The following tables indicate the appropriate pressures on the burner ramp:

Frymaster CF — CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 19)
Fig. 13
Table 4EC standard Gas pressure at burner ramp
Table 5EC Standard - Belgium Gas Pressures at Burner ramp

(mbar) Natural gas from Lakeq (G20) under 20 mbar 9 7.5 7.5

(mbar) Natural gas from Lakeq (G20) under 20 mbar 9 7.5 7.5

Natural gas from Gronic (G25) under 25 mbar 13.5 10 10

Natural Gas of Gronics (G25) under 25 mbar 9 7 7

Natural gas from Gronique (G20) under 20 mbar 13.5 10 10

Natural Gas of Gronic (G20) under 20 mbar 9 10 10

Propane (G31) under 37 or 50 mbar 22.5 20.6 14.9

Propane (G31) under 37 or 50 mbar 22.5 20.6 14.9

Table 6Non-CE Standard Gas Pressures at Burner ramp
Page 20 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 20 · click to enlarge
Page 20

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.4. Gas connection (cont'd) 5. Check the calibration of the thermostat or the temperature programmed in the computer.

  • For thermostat-equipped devices, refer to the thermostat calibration instructions (Chapter 5).
  • For devices equipped with other types of controllers, refer to the appropriate section in Frymaster - User Manual Frieser Controllers provided with your fryer describing the programming and operating instructions for your controller. 2.5 Conversion to another type of gas Your fryer is configured for natural gas or propane in a factory. If you want to change the type of gas, a conversion kit will have to be installed by an Frymaster SAV center technician.

cause a fire or explosion. NEVER CONNECT THIS DEVICE TO A

GAS NETWORK FOR WHICH IT WAS NOT CONFIGURED!

The conversion of this apparatus from one type of gas to another shall be carried out only by

a qualified, licensed and authorized installation or maintenance personnel defined in

Section 1.7 of this manual.

Page 21 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 21 · click to enlarge
Page 21

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.5 Conversion to another type of gas (cont'd)

EC gas conversion instructions 1. Between natural gases of type G20 and G25, adjust the gas pressure to the regulator. (See the EC standard burner ramp gas pressure table.) Do not change the orifice or light. 2. Between a second family gas (G20 or G25) and a third family gas, profan G31: a. Change the openings. b. Change the light. c. Change the regulator or gas tap. d. Adjust the pressure of the burner ramp. 3. Remove the plate from nominal values and install a new one. Call your local maintenance agent or kitchen equipment supplier to get a new plate. 4. If the language of destination changes, replace labels. Call your local maintenance agent or kitchen equipment supplier to get a label kit. The reference language appears at the corner of the label. The following components and conversion kit are available from your Frymaster VAS center:

EC only:

Propane (G31) with natural gas (G20/G25) Regulator only: Ref. No. 810-1292 Watch, regulator and orifice kit : Ref. 826-1478 (MJCFE) ; ref. No. 826-1203 (MJ45E) Propane (G31) Natural Gas (G20/G25) Regulator only: Ref. No. 810-1292 Watch, regulator and orifice kit : Ref. 826-1204 (MJCFE) ; ref. No. 826-1202 (MJ45E)

MJ35 only: No EC conversion kit is offered for the 35 series. Honeywell G31 gas valves (propane) can be adjusted for natural gases G20 and G25, but the G20 gas valves and G-25 gas faucets cannot be fitted for G31. Therefore, in case of conversion from a G20 or G25 gas to the G31 gas, in addition to the light and apertures, the valve shall be changed. The table below identifies the parts required for a conversion from one gas family to another:

2nd family (G20/G25) to 3rd family ( G31) 3rd Family (G31) to 2nd Family ( G20/ G25)

826-1354 (pack of 10 burner holes) 826-135 (pack with 10 burner openings)

810-0427 Watchholes (2 required)* 810 0426 Watchhole (2 required)*

807-2121 EC gas valve (millivolts) Adjustable gas faucet (no replacement required)

* Required quantity: 1unless otherwise specified.

Page 22 of the Frymaster CF user manual — CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 22 · click to enlarge
Page 22

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.5 Conversion to another type of gas (cont'd)

Conversion instructions to a non-EC gas For fryers at 1,524 m or more altitude, call the Frymaster SAV (1-800-551-8633) to determine appropriate components for your configuration and elevation. Contact the nearest Frymaster VAS center to order components and make an appointment for installation. For fryers less than 1,524 m, see the kits below for conversion.

Non-EC only: Propane (G31) natural gas Conversion kit for regulator: Ref. No. 807-1846 (all non-EC) Watch, controller conversion kit and orifice set : Ref. No. 826-1747 (MJCF) ; ref. No. 826-1141 (J1C) ; ref. No. 826-1139 (MJ35) ; ref. No. 826-1143 (MJ45) Propane (G31) with natural gas (G20/G25) Conversion kit for regulator : Ref. No. 807-1849 (all non-EC) Watch, controller conversion kit and orifice set : Ref. No. 826-1748 (MJCF) ; ref. No. 826-1142 (J1C) ; ref. No. 826-1158 (MJ35) ; ref. No. 826-1144 (MJ45)

Page 23 of the Frymaster CF user manual — 3.1. Release procedure
Page 23 · click to enlarge
Page 23

CHAPTER 3: DIRECTIONS FOR USE

3.1. Release procedure

Frymaster CF — 3.1. Release procedure diagram (page 23)
Fig. 14 · 3.1. Release procedure

water, vegetable oil or fat before burning burners under penalty

damage the frying basin and cause a fire.

Frymaster CF — 3.1. Release procedure diagram (page 23)
Fig. 15 · 3.1. Release procedure

the risks inherent in using a hot oil filtering system, particularly

the procedures for filtering, emptying and cleaning.

Frymaster CF — 3.1. Release procedure diagram (page 23)
Fig. 16 · 3.1. Release procedure

frying basin is closed. Remove the support from the basket, if applicable, and fill in the

If solid vegetable fat is used in fryers with the fusion cycle option,

Make sure the fat is well packed at the bottom of the frying basin.

In fryers without the option Melting cycle, solid vegetable fat must be melted

Non-EC gas valve Devices configured for use in non-EC countries are equipped with

Honeywell non-EC taps.

CE gas valve The appliances configured for use in EC countries are equipped with Honeywell CE valves.

Page 24 of the Frymaster CF user manual — CHAPTER 3: DIRECTIONS FOR USE
Page 24 · click to enlarge
Page 24

CHAPTER 3: DIRECTIONS FOR USE

3.1. Procedure for commissioning (cont'd) Make sure that the following steps are performed in sequence before turning on or off again: 1. Close the manual stop valve of the arrival line.

2. Lower the thermostat or semiconductor controller to a maximum, or turn off the computer or controller.
3. No-CE: Close the gas tap. CE: Push the Safety Gas Tap (red) switch off to close it.
4. Wait at least 5 minutes to disperse the accumulated gas.
5. Fill the basin with oil, liquid vegetable fat or water to the lower LEVEL OIL mark at the back of the frying pond. Solid vegetable fat: Melt solid plant fat before pouring into the frying basin. ACCESS TO THE LIGHT

The light is mounted on the left side of the burner ramp and accessible by opening in front insulation from the frying basin. Open the round lid and insert a long match or wick into the hole (see. photo) to turn on the light.

Frymaster CF — CHAPTER 3: DIRECTIONS FOR USE diagram (page 24)
Fig. 17

Insert a match or

wick in this orifice

Until the nightlight.

Page 25 of the Frymaster CF user manual — PILOT
Page 25 · click to enlarge
Page 25

CHAPTER 3: DIRECTIONS FOR USE

3.1 Procedure for commissioning (cont'd) ALLUMING OF THE VILLEuse ON NON-EC FRITIES 1. Make sure the unit is energized, then close the gas tap. Wait at least 5 minutes, then turn the gas valve button to PILOT position (see Figure 1).

Lighting of the light

PILOT

PILOT

OFF

OFF

ON

ON

Figure 1 Figure 2 2. Press the gas tap button and turn on the light. (If the fryer is equipped with a piezoelectric light, press the ignition button several times while pressing the gas valve button until the alarm lights up.) Continue to push the tap button for about 60 seconds after the switch on the wake. Release the button. The light must remain on.

minutes before trying to turn it on again. IGNITION OF THE LIGHT ON GAS TAP FRYERS THIS HONEYWELL 1. Make sure the device is off, then press the stop button (red). Wait five minutes.

Frymaster CF — PILOT diagram (page 25)
Fig. 18

EC gas valve Honeywell (24 V)

OFF button (stop) Button of the light

Page 26 of the Frymaster CF user manual — CHAPTER 3: DIRECTIONS FOR USE
Page 26 · click to enlarge
Page 26

CHAPTER 3: DIRECTIONS FOR USE

3.1. Procedure for commissioning (cont'd) 2. If the fryer is equipped with a piezoelectric light, Press and hold down the white button of the light, then repeatedly press on the switch until the light lights up.

If the fryer is not equipped with a piezoelectric ignition, Place a flame near the light, press the PILOT button (white), turn on the light and continue pressing the switch for at least 60 seconds after ignition of the light. 3. Release the white button after 45 to 60 seconds. If you do not hold the button down long enough, the light will shut off as soon as it is released. If the light shuts off when the button is loosened, wait for 5 minutes minimum and then resume procedure. START-UP OF THE FRYER

Section 3.2, Boiling procedure.

For apparatus equipped with thermostats If applicable, place the Melt Cycle switch on position ON (Marche). Turn the thermostat at the desired cooking temperature. The U-burner must light and burn with a powerful blue flame.

fused until the switch is placed on OFF (stop).

For apparatus equipped with a device other than thermostat Place the computer/stop switch on position ON (Wash) and set the controller – or program the computer – to the desired cooking temperature, called point of entry. The U-burner must light and burn with a powerful blue flame. The apparatus automatically switches to the fusion cycle mode if the temperature of the frying basin is less than 82 °C. (REMARK : During the melting cycle, the burner lights up several times for a few seconds and then turns off a little longer.) When the temperature of the frying basin reaches 82oC, it automatically switches to Heat mode. The burner remains on until the temperature of the frying basin reaches the scheduled cooking temperature.

Page 27 of the Frymaster CF user manual — CHAPTER 3: DIRECTIONS FOR USE
Page 27 · click to enlarge
Page 27

CHAPTER 3: DIRECTIONS FOR USE

3.2 Boiling procedure To ensure that the fryer is free from any contamination resulting from its manufacture, shipment and handling during installation, you must boil a mixture of water/detergent in the frying basin before it first uses. Frymaster recommends this procedure every time you change your bath oil or vegetable fat.

minutes before you resume the procedure. To reduce the risk of overflow, turn

from time to time the gas tap of the fryer on PILOT position.

1. Before turning on the burner, close the drain tap(s) of the frying basin and fill the tank to the lower OIL-LEVEL line with a mixture of cold water and dishwashing detergent. 2. For apparatus equipped with a thermostat or semiconductor controller (analogue):

Non-EC: Set the thermostat to the lowest. Turn on the fryer as described in section 3.1 (Lighting procedure for non-EC fryers). Let the solution reach a boil, then turn the gas tap button on PILOT. Let the solution rest for 30 minutes. Open the gas by turning its button on ON and wait until the solution gets boiled. Turn the gas tap button on PILOT and let it rest for 30 minutes. Go to step 8 of this section. CE : Set the thermostat to the lowest. Turn on the fryer as described in section 3.1 (Lighting procedure for EC fryers). Wait until the solution boils, then press RED button to close the gas tap. Let the solution rest for 30 minutes. Turn on the fryer as described in section 3.1 (Lighting procedure for EC fryers). Wait until the solution boils, then press RED button to close the gas tap. Let the solution rest for 30 minutes. Go to step 8 of this section. 3. On appliances equipped with a digital controllerSet the set point to 195°F (91°C). 4. On appliances equipped with a automatic basket timer, press the Boil Mode button

to start the procedure. 5. On devices equipped with a computer Computer Magic III.5:

  • Press the on/off switch

, then on the switch Programming mode

appears in the left display.

. The temperature is automatically set to 195 oF (91oC). The fryer reaches this temperature and stays there until you press the on/off switch, which cancels the boiling mode.

  • Enter the code number

(1653). L-show to right indicates

Page 28 of the Frymaster CF user manual — CHAPTER 3: DIRECTIONS FOR USE
Page 28 · click to enlarge
Page 28

CHAPTER 3: DIRECTIONS FOR USE

3.2 Boiling procedure (cont'd) 6. Turn the fryer on in accordance with section 3.1 procedure [except Thermostat or semiconductor controller (analog) - see. Step 2]. 7. Simmer the solution for one hour [except Thermostat or semiconductor controller (analog) - see. Step 2]. 8. Once the solution has simmered for one hour [except Thermostat or semiconductor controller (analog) - see. Step 2], turn off the fryer, let cool down the solution and add 8 liters of cold water and mix. Empty the solution in a suitable container and thoroughly clean the frying basin.

damaged by the solution. 9. Rinse the frying basin at least twice by filling it with clean water before emptying. Carefully wipe the frying basin with a clean, dry towel.

fill with vegetable oil or fat. Follow this instructions, or cause the projection of hot vegetable oil or grease during the heating cycle

at the cooking temperature, which could cause injury to staff

- I'm not.

3.3 Stopping the fryer For a short stop during your working day, place the fryer switch/stop on Stop (OFF) and put lids on the frying basins (if applicable). When you turn off the fryers at the end of the day, place the on/off switch in the Frozen Stop (OFF) position, close the gas tap and put lids on the frying basins (if applicable). 3.4 Controller's manual and programming The CF series can be equipped with a Computer Magic (CMIII.5), an automatic basket timer, digital controller, semiconductor controller (analog) or thermostat. A manual is provided with CF fryers equipped with a computer or controller.

Page 29 of the Frymaster CF user manual — 4.1 Manual emptying and filtering
Page 29 · click to enlarge
Page 29

CHAPTER 4: FILTER INSTRUCTIONS

4.1 Manual emptying and filtering

Frymaster CF — 4.1 Manual emptying and filtering diagram (page 29)
Fig. 19 · 4.1 Manual emptying and filtering

the risks inherent in using a hot oil filtering system, particularly

the procedures for filtering, emptying and cleaning.

Frymaster CF — 4.1 Manual emptying and filtering diagram (page 29)
Fig. 20 · 4.1 Manual emptying and filtering

in the right position before handling buttons or valves. Wear the appropriate safety equipment in full during oil or filter discharge and filtering

vegetable fat.

Frymaster CF — 4.1 Manual emptying and filtering diagram (page 29)
Fig. 21 · 4.1 Manual emptying and filtering

vegetable fat is projected on the burner. Applying the burner heat to an empty frying basin will cause severe damage to the frying pond and cancel guarantees.

a suitable container for scrapping. If your fryer is not equipped with an integrated filtering system, the vegetable oil or fat cooking should be emptied into another suitable container. To empty and dispose of used vegetable oil or grease easily and safely, Frymaster L.L.C. recommends the use of the container for scrapping vegetable fat (SDU) Frymaster. The SDU is available at your distributor.

Frymaster CF — 4.1 Manual emptying and filtering diagram (page 29)
Fig. 22 · 4.1 Manual emptying and filtering

or a portable filter, do not fill beyond the maximum filling line,

located on the container. 1. Stop the fryer by placing its on/off switch on OFF. Screw the drain pipe (provided with your fryer) into the discharge valve. Make sure the drain pipe is firmly screwed on the discharge valve and that the opening points downwards.

Page 30 of the Frymaster CF user manual — CHAPTER 4: FILTER INSTRUCTIONS
Page 30 · click to enlarge
Page 30

CHAPTER 4: FILTER INSTRUCTIONS

4.1 Manual emptying and filtering (cont'd) 2. Place a metal container with watertight lid under the drain pipe. The metal receptacle shall be able to withstand the heat of vegetable oil or fat and contain hot liquids. If you intend to reuse vegetable oil or fat, use a conical filter holder and Frymaster Conic Filter when a filter machine is not available. If you use a Frymaster conical filter holder, make sure that it is safely placed on the metal container. 3. Slowly open the drain valve to avoid projections. If it is mouthing (food particles), use the Fryers Friend tool to open it.

Burning vegetable fat will come out at once, which presents an extreme danger.

The ball and compromise its seal, which will cause leaks. 4. After draining vegetable oil or fat, remove all food particles and the remaining vegetable oil/fat from the frying basin. Be careful as the frying pelvis can cause severe burns in contact with naked skin. 5. Close the drain valve and fill the basin with fresh or filtered solid vegetable oil or grease until you reach the lower OIL-LEVEL line.

Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 30)
Fig. 23

the frying basin. Do NOT use the fryer with a solid block of vegetable fat in the upper part of the frying basin Risk of irreparable damage to the deep-water pond

Page 31 of the Frymaster CF user manual — CHAPTER 4: FILTER INSTRUCTIONS
Page 31 · click to enlarge
Page 31

CHAPTER 4: FILTER INSTRUCTIONS

4.2 Directions for the Filter Magic II filtering system Filter Magic II filter system allows filtering of cooking oil or vegetable grease in a frying basin while other frying pools continue to work. THIS SECTION DOES NOT APPLY TO J1C SERIES FRYERS. The main causes of system malfunction are incorrect installation of filter holder or filter paper sieve and improper use of the filter powder. Follow the detailed instructions below carefully to ensure that your system will work as expected. PREPARATION OF THE FILTER FOR USE AND/OR REPLACEMENT OF FILTER PAPER 1. Slip the filter out of the cabinet and remove the paper tray and holding ring. Remove any used filter paper that may be in the bin.

Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 31)
Fig. 24
Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 31)
Fig. 25
Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 31)
Fig. 26
2. Remove the sieve from the filter holder.

which could prevent the paper from adhering to the bottom of the tray.

Page 32 of the Frymaster CF user manual — CHAPTER 4: FILTER INSTRUCTIONS
Page 32 · click to enlarge
Page 32

CHAPTER 4: FILTER INSTRUCTIONS

4.2 Directions for the Filter Magic II filtering system (cont'd) 3. Wipe the particles and excess of oil or vegetable fat from the bottom of the tray. The paper must be flat-set and stick well to the edges for proper filtering. Return the filter holder sieve removed to step 2.

Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 32)
Fig. 27
Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 32)
Fig. 28
4. Put a sheet of filter paper over the filter pan, overflowing on all sides.
Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 32)
Fig. 29
5. Position the holding ring on the paper filter and lower it in the tray to allow the paper to fold around when pushed into the bottom of the pan.
Page 33 of the Frymaster CF user manual — CHAPTER 4: FILTER INSTRUCTIONS
Page 33 · click to enlarge
Page 33

CHAPTER 4: FILTER INSTRUCTIONS

4.2 Directions for the Filter Magic II filtering system (cont'd)

Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 33)
Fig. 30
6. Sprinkle filter powder on the paper filter. For the amount of powder to be used, refer to manufacturer's instructions.
Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 33)
Fig. 31
7. Put the tray in the filter pan.
Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 33)
Fig. 32
8. Install the filter in the cabinet (arrow). Make sure the connector on the cabinet is securely connected to that of the cupboard. The system is ready for filtering.
Page 34 of the Frymaster CF user manual — CHAPTER 4: FILTER INSTRUCTIONS
Page 34 · click to enlarge
Page 34

CHAPTER 4: FILTER INSTRUCTIONS

4.2 Directions for the Filter Magic II filter system (cont'd) METHOD OF USE OF THE FILING SYSTEM

cooking temperature [~177 °C (~350 °F)].

Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 34)
Fig. 33
1. To filter the frying oil, turn off the fryer (OFF), then open the emptying valve of the fry machine you have chosen to filter out the oil. If necessary, use the Fryer's Friend steel cleaning rod to open up the drain from inside the frying basin.

Discharge valve in open position.

contents of a single frying basin.

NEVER try to open a drain valve from the front! Oil or

Hot vegetable fat may come out of the box and burn you seriously.

Do NOT tap the drain valve with cleaning rod or other objects under

harm the inner ball, which would cause leaks and cancel

Frymaster warranty.

Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 34)
Fig. 34
2. When the frying basin is empty, use a long handle and hard bristle brush to remove sediment from the walls of the fryer pond. By cleaning the inside of the frying basin, avoid hitting the overheating thermostat and temperature sensor or control thermostat (photo JCMF arrows).

Avoid hitting the thermostatic bulbs during cleaning of the frying basin.

Page 35 of the Frymaster CF user manual — CHAPTER 4: FILTER INSTRUCTIONS
Page 35 · click to enlarge
Page 35

CHAPTER 4: FILTER INSTRUCTIONS

4.2 Directions for the Filter Magic II filtering system (cont'd)

Expelled from the fryer and is likely to cause injury.

Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 35)
Fig. 35

Oil return handle in open position.

3. Snap the Power Shower into the frying basin. Make sure that the cleaning plugs are in place before turning on the filter pump. Once the oil is out of place in the frying basin, DRIVE on the filter handle (arrow) to start the pump and begin filtering. You will see a slight delay in the pump activation.
Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 35)
Fig. 36
4. L-oil flows through the Power Shower, eliminating particles from the frying basin. Continue to circulate vegetable oil or fat through the filter for 5 minutes.
Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 35)
Fig. 37

Oil return handle in closed position.

5. Once the oil is filtered, close the drain valve and let the fryer fill. When bubbles appear in the oil, let the filter run for 10 to 12 seconds more to unload pipes and prevent grease from hardening inside, then POW the filter handle on position Stop (OFF) (arrow).
Page 36 of the Frymaster CF user manual — CHAPTER 4: FILTER INSTRUCTIONS
Page 36 · click to enlarge
Page 36

CHAPTER 4: FILTER INSTRUCTIONS

4.2 Directions for the Filter Magic II filtering system (cont'd) 5. Remove the Power Shower and let it drain. Make sure the drain valve is completely closed (arrow). Put the fryer on (ON) and let vegetable oil or fat reach its point of delivery.

Frymaster CF — CHAPTER 4: FILTER INSTRUCTIONS diagram (page 36)
Fig. 38

Discharge handle in closed position.

the engine of the electrical filtering or failure system. If this switch breaks, turn off the filter system and let the pump motor cool for

20 to 45 minutes before attempting to rearm it.

Page 37 of the Frymaster CF user manual — use and pre-use precautions. Pay special attention
Page 37 · click to enlarge
Page 37

CHAPTER 5: PREVENTIVE MAINTENANCE

5.1 Preventive maintenance and maintenance checks for the fryer CONTROLS AND QUOTIIAN MAINTENANCE Inspection of the frying machine and accessories Pay particular attention to the detection of worn wires and cords, leaks, foreign materials in the frying basin and inside the cabinet, and any other symptoms indicating that the fryer and accessories are not ready for safe operation. Check the ceramic burner targets. Make sure the targets are in position above each orifice and that the flame lights up about 60 mm above the opening. The flame must strike the centre of the target and be deep blue. If there's a problem, call your Frymaster VAS Center. Cleaning of the inside and outside of the fryer cabinet

projections that can seriously burn staff in the vicinity.

use and pre-use precautions. Pay special attention

the concentration and duration of action of the cleaner on surfaces in

contact with food. Clean the inside of the fryer cabinet with a clean dry cloth. Pass the cloth over all accessible surfaces and metal components to remove vegetable oil or grease and dust that have accumulated. Clean the outside of the fryer cabinet with a clean cloth saturated with dishwashing detergent, removing vegetable oil or fat, dust and stuffed. Filtration of cooking vegetable oil or grease The cooking oil or vegetable grease used in the fryer must be filtered at least once a day (more often if the frying machine is constantly being used). For details, see Chapter 4, Filter Instructions.

Page 38 of the Frymaster CF user manual — CHAPTER 5: PREVENTIVE MAINTENANCE
Page 38 · click to enlarge
Page 38

CHAPTER 5: PREVENTIVE MAINTENANCE

5.1 Preventive maintenance and fryer maintenance checks (cont'd) WEEKLY CONTROLS AND MAINTENANCE Uplift time control (computer-operated dryers only) The rise time corresponds to the fryer's required time to increase the temperature of the frying basin from 135°C (275°F) to 163°C (325°F). This is a measure of the fryer efficiency which must not exceed 2 minutes 30 seconds for MJ45 series fryers and 3 minutes 30 second for M JCF series frridges. The time to return on models equipped with a CM III.5 computer is automatically measured by the computer. To display the time to go back on models equipped with CM III.5 computers, press the button

(1652) using the digital keys. The return time appears in both displays for 5 seconds. TRIMESTRIAL CONTROLS AND MAINTENANCE Empty and cleaning of the frying basin During normal use of your fryer, a deposit of carbonised vegetable oil or fat will gradually form inside the frying basin. This deposit must be periodically removed to maintain the efficiency of the fryer.

left side. Enter the code

empty into a suitable container for discarding. If your fryer is not equipped with a filter system built-in Filter Magic II, the vegetable oil or fat cooking should be emptied into another suitable container. (To empty and dispose of used vegetable oil or grease easily and safely, Frymaster recommends the use of the container for scrapping vegetable fat (SDU). The SDU is available at your distributor.

Programming mode

Page 39 of the Frymaster CF user manual — CHAPTER 5: PREVENTIVE MAINTENANCE
Page 39 · click to enlarge
Page 39

CHAPTER 5: PREVENTIVE MAINTENANCE

5.1 Preventive maintenance and fryer maintenance (cont'd) Cleaning of detachable components and accessories As with the frying basin, a carbonised oil or vegetable grease deposit will accumulate on detachable components and accessories such as baskets, sediment trays or clasps. Pass a clean cloth moistened with detergent solution over all detachable components and accessories. Rinse and wipe thoroughly each component. Verification of the calibration of the thermostat or semiconductor controller temperature control button (analogue) [NOTES: This check applies only to devices equipped with a thermostat or semiconductor controller (analog).] 1. Make sure that the frying basin is filled with liquid vegetable oil or grease. 2. Set the temperature control button to frying temperature. 3. Allow the burner to do three automatic ignition and extinguishing cycles so that oil or grease temperature is uniform. Stir as needed to ensure that all vegetable oil or fat is melted at the bottom of the frying basin. 4. Insert a confectioner thermometer or pyrometer probe into the vegetable oil or grease, touching its tip and temperature sensor of the fryer. 5. When the burner lights up for the fourth time, the thermometer or pyrometer reading shall be within ± 2 oC of the selected setting with the button. If not, calibrate as follows:

a. Unlock the screw of the temperature control button until the button turns freely

on the axis. b. Turn the thermostat until its d-index line is aligned to the mark corresponding to the reading

thermometer or pyrometer. c. Hold the selector and tighten the screw.

d. Check the thermometer or pyrometer reading against the button setting at

Next ignition of the burner.

e. Take steps 4.a. at 4.d. until the thermometer or pyrometer reading and adjustment

The button corresponds to ± 2 oC. If calibration is not possible, contact an approved VAS centre for assistance.

Page 40 of the Frymaster CF user manual — CHAPTER 5: PREVENTIVE MAINTENANCE
Page 40 · click to enlarge
Page 40

CHAPTER 5: PREVENTIVE MAINTENANCE

5.1 Preventive maintenance and fryer maintenance checks (cont'd) Thermostat calibration check

(This check applies only to fryers equipped with a thermostat.)

1. Make sure that the frying basin is filled with liquid vegetable oil or grease. 2. Set the temperature control button to 162°C (325°F) and insert a confectioner thermometer or pyrometer probe into the frying basin so that it touches protection of the temperature sensor. 3. When the burner is extinguished, set the temperature control button to 170°C (340°F). When the thermometer or pyrometer reading is close to setting the control button, but before the burner turns off, bring the switch back to 162°C (325°F). Just when the thermometer or pyrometer reading drops below 162°C (325°F), the burner must re-light. Otherwise, calibration is mandatory. Contact an approved VAS centre for maintenance. Computer Magic III controller's accuracy control (REMARK This control applies only to fryers equipped with a Computer Magic III.5).

1. Insert a confectioner thermometer or pyrometer probe into the vegetable oil or grease, touching its tip and temperature sensor of the fryer.
2. When computer displays

dot between the first and second indents (indicating that the contents of the frying basin are in the cooking interval), press once on the button

to display the temperature of cooking oil or vegetable grease as detected by the temperature probe.

3. Press the button twice

to display the set point. 4. Note the temperature on the thermometer or pyrometer. The three surveys shall be within ± 2 oC of each other. If not, contact an approved VAS centre for assistance.

Cleaning the gas valve nozzle 1. Carefully remove the gas tap nozzle. (REMARK : The nozzle can be straightened.) 2. Put a piece of regular wire (1.3 mm diameter) into the nozzle to clean it. 3. Remove the wire and blow into the nozzle to make sure it is clean.

Page 41 of the Frymaster CF user manual — CHAPTER 5: PREVENTIVE MAINTENANCE
Page 41 · click to enlarge
Page 41

CHAPTER 5: PREVENTIVE MAINTENANCE

5.1 Preventive maintenance and fryer maintenance checks (cont'd) 4. Reinstall the nozzle and curve it so that its opening points down. SEMI-ANNUAL CHECKS AND MAINTENANCE

Control of the burner ramp pressure

Contact your Frymaster VAS centre to make an appointment. 5.2 Preventive maintenance and maintenance checks of Filter Magic II filtering system There is no preventive maintenance periodical control required for your Filter Magic II filter system other than daily cleaning of the external and internal filters with hot water solution and detergent. Turn the filter pan and lift it slightly on one side to allow water to completely drain from the suction tube. If you notice that the system is pumping slowly or not at all, make sure that the sieve in the tray is located at the bottom of the bin and paper over the sifter. If the filter sieve and filter paper are properly installed, change the filter paper and check if O-rings of the fitting (inside the cabinet, back) are present in good condition. NOTES: Once the paper is finished and O-rings are properly installed, the system must fill the fryer in 2 to 3 minutes. Immediately after each use, completely empty the Power Shower. If you suspect a lock, unscrew the plugs from cleaning holes in each corner of the chassis. Place the chassis in a hot water pan for several minutes to melt solidified vegetable oil or fat. Use a long narrow pin, hot water and detergent to clean the inside of tubes. If necessary, insert a straightened trombone or similar instrument into the holes in the frame to open. Rinse, wipe well and re-install the caps before use.

d) Burning oil from the frying basin during filtering and therefore, of

risk of burn for staff.

Page 42 of the Frymaster CF user manual — CHAPTER 5: PREVENTIVE MAINTENANCE
Page 42 · click to enlarge
Page 42

CHAPTER 5: PREVENTIVE MAINTENANCE

  • 5.3 Periodic or annual system inspection This device shall be inspected and adjusted by qualified maintenance personnel as part of a standard kitchen maintenance program. Frymaster recommends that the aircraft be inspected annually (or more frequently) by an approved maintenance agent:
  • Inspect the inner and outer cabinet, front and rear to ensure that you do not have excessive deposit or oil infiltration.
  • Make sure that the smoke duct is not opened by particles or build-up of solidified vegetable oil or fat.
  • Make sure that burners and associated components (gas rings, lighters, etc.) are in good condition and work properly. Inspect all gas fittings to ensure they are not leaking and that they are tight.
  • Make sure that the burner ramp pressure matches the one specified on the device's nominal value plate.
  • Make sure that the temperature and overheating protection probes are properly connected and tightened, and they work correctly, and that sounders are present and installed properly.
  • Make sure that the components of the component housing (i.e. computer/controller, relays, interface cards, transformers, etc.) are in good condition and do not carry any traces of oil or other dirt deposits. Make sure that the wires in the components housing are safe and have a good working condition.
  • Make sure that all security (i.e., drain safety switches, rearming switch etc.) are present and functioning properly.
  • Make sure the frying basin is in good condition, that it does not leak and its insulating material is in a good working order. Make sure that the vents of the frying basin tube are present and in good condition (no visible signs of deterioration or damage).
  • Make sure that the conductor wire bundles and all connections are safe and in good condition.
Page 43 of the Frymaster CF user manual — CHAPTER 5: PREVENTIVE MAINTENANCE
Page 43 · click to enlarge
Page 43

CHAPTER 5: PREVENTIVE MAINTENANCE

  • 5.3 Periodic or annual system inspection (cont'd) Integrated filtering
  • Inspect all oil drain and return pipes to ensure no leaks are present and check the safety of any connections.
  • Inspect the filter tray to ensure that there are no leaks and check its cleanliness. If there is a significant accumulation of crumbs in the crumb tray, advise the operator or owner that it should be emptied into a flame retardant container and cleaned daily.
  • Make sure all O-rings and seals (including those of the Power Shower and quick demountable fittings) are present in good condition. Replace O-rings and seals if worn or damaged.
  • Check the integrity of the filtering system as follows:

- After draining the filter pan, place each oil return handle on a March (ON) position, one after another. Make sure that the pump is activated and bubbles appear in cooking vegetable oil or grease (or you hear gargouts at the power shower opening) of the associated basin.

- Close all oil return valves (by placing all the oil back handles in OFF position). Check the correct operation of each oil return valve by activating the filter pump using the lever on one of the micro-switches in the oil back handle. No air bubbles should be visible in the frying basin (and you must not hear any gurgling at the Power Shower's orifices).

- Make sure the filter tray is properly prepared for filtering, then pour the oil heated to 177°C (350°F) from the frying basin into the tank and close the emptying valve of the fryer pond. Place the oil return handle on March (ON) position. Allow all vegetable oil or fat to be returned into the frying basin (this is indicated by bubbles in vegetable oil and/or grease, or on Power Showers models, stop oil flow from the Power Shower). Place the oil return handle on Stop position (OFF). The frying basin must be filled within 2 minutes 30 seconds.

Page 44 of the Frymaster CF user manual — CHAPTER 5: PREVENTIVE MAINTENANCE
Page 44 · click to enlarge
Page 44
Page 44 of the Frymaster CF user manual — CHAPTER 5: PREVENTIVE MAINTENANCE
Page 45 of the Frymaster CF user manual — CHAPTER 5: PREVENTIVE MAINTENANCE
Page 45 · click to enlarge
Page 45

ATMOSPHERIC GAS FRYERS MASTER JET CHAPTER 6: OPERATOR-POSSIBLE TROUBLESHOOTING

6.1 Introduction This chapter serves as a quick reference guide to certain common problems that may occur during the operation of the apparatus. The troubleshooting guides in this chapter allow correcting or, at least, accurately diagnosing the problems encountered with this device. Even though this chapter covers most of the problems that are reported, you may encounter issues not addressed here. In this case, Frymaster's technical assistance staff will do their best to help you identify and resolve the problem. In addition, it should be noted that troubleshooting guides may not apply to certain models. To solve a problem, always proceed by elimination from the simplest to most complex solution. Never neglect the obvious. Anyone can forget to plug a power cord or put a piece of filter paper into the filter tray. You're no exception to the rule. The most important thing is always trying to identify the cause of a problem. Any corrective procedure shall include measures to ensure that the problem does not recur. If a controller is malfunctioning due to faulty connection, check all other connections at the same time. If a fuse continues to burn, look for reasons. Always keep in mind that failure of a small component can often indicate potential breakdown or incorrect operation of any larger component or system. If you have any doubts about the correct action to take, please call Frymaster Technical Service or your FryMaster approved VAS Center for assistance.

transfer hot vegetable oil or fat from one container to another.

This device can have more than one point of connection to the sector. Disconnect all the

power cords before maintenance.

Inspection, testing and repair of electrical components shall be performed by a

Approved maintenance agent.

Page 46 of the Frymaster CF user manual — OU
Page 46 · click to enlarge
Page 46

ATMOSPHERIC GAS FRYERS MASTER JET CHAPTER 6: OPERATOR-POSSIBLE TROUBLESHOOTING

6.2 Troubleshooting of semiconductor (analog) or digital or CM III.5 control fryers

PROBLEM LIKELY CAUSES CORRECTIVE ACTION

A. Clean it in accordance with the

A. The light is not on.

instructions in Chapter 3 of this manual.

B. The drain valve is open. B. Make sure that the tap

emptying is completely closed.

C. Make sure the fryer is

C. The fryer is not fed

connected to the sector and that breaker did not jump.

electricity.

D. Make sure the connections

The burner doesn't turn on.

the gas network has been properly operated, all safety valves between the fryer and the gas system are open and the main gas valve is opened.

D. The fryer is not fed

Gas.

E. If possible, replace the controller

Suspected by another in working order. If the fryer is working normally, order a replacement controller from the VAS centre. The controller's power and error lights

E. Controller's down.

If possible, replace the suspect controller with another one in working order. If the fryer is working normally, order a replacement controller from the VAS centre. If the fryer does not work normally, have the temperature probe circuit checked. Call the Frymaster VAS Center.

(analog) are on, but not the

Controller's down. Temperature sensor broke.

OU

displayed on CM III.5.

If possible, replace the suspect controller with another one in working order. If the fryer is working normally, order a replacement controller from the VAS centre. If the fryer does not work normally, have the temperature probe circuit checked. Call the Frymaster VAS Center.

The fryer is continuously in Fusion Cycle mode.

Controller's down. Temperature sensor broke.

Semiconductors · heating light,

Page 47 of the Frymaster CF user manual — OU
Page 47 · click to enlarge
Page 47

ATMOSPHERIC GAS FRYERS MASTER JET CHAPTER 6: OPERATOR-POSSIBLE TROUBLESHOOTING

6.2 Troubleshooting of semiconductor (analog) or digital or CM III.5 controller fryers (cont'd)

PROBLEM LIKELY CAUSES CORRECTIVE ACTION

A. Disconnect the mains outlet,

Wait at least a minute, reconnect the unit to power and turn on the controller. CM III.5 cannot

A. Temporary dysfunction of the

controller caused by an overvoltage.

B. If possible, replace the controller

access the mode of

Suspected by another in working order (see Section 6.6). If the fryer is working normally, order a replacement controller from the VAS centre.

programming.

B. Controller's down.

A. Make sure that the point of

A. Incorrect set-up.

order has been entered correctly.

The following table shows the results of this study:

B. Disconnect the mains outlet,

B. Temporary dysfunction of the

Wait at least a minute, then reconnect the unit to the mains.

controller caused by an overvoltage.

OU

The mode of view

C. If possible, replace the controller

Suspected by another in working order (see Section 6.6). If the fryer is working normally, order a replacement controller from the VAS centre.

Not at all. C. Controller's down.

A. See the problem The

burner does not turn on, page 6-2. The heating mode light lights up, but

A. The burner is not on.

B. If possible, replace the controller

Suspected by another in working order (see Section 6.6). If the fryer is working normally, order a replacement controller from the VAS centre.

fryer does not heat

Not right. B. Controller's down.

fusion cycle · heating does not turn on

Page 48 of the Frymaster CF user manual — 6.3 Troubleshooting of thermostat fryers
Page 48 · click to enlarge
Page 48

ATMOSPHERIC GAS FRYERS MASTER JET CHAPTER 6: OPERATOR-POSSIBLE TROUBLESHOOTING

6.3 Troubleshooting of thermostat fryers

PROBLEM Probable causes Corrective action

A. Clean it in accordance with the

instructions in Chapter 3 of this manual. B. The drain valve is not

A. The light is not on.

B. Make sure that the tap

completely closed.

emptying is completely closed.

C. Make sure the fryer is

The burner doesn't turn on.

correctly connected to the sector and that breaker did not skip.

C. The fryer is not fed

electricity.

D. Make sure the connections

the gas network has been properly operated, all safety valves between the fryer and the gas system are open and the main gas valve is opened. The fryer does not access the Cycle mode of

D. The fryer is not fed

Gas.

Breaker of the melting cycle inoperative. Map of printed circuits in the defective fusion cycle.

Replace the switch or card. Call the Frymaster VAS Center.

or remains in

permanent.

The exact problem detection requires further operations that go beyond the operator's intervention. Call the Frymaster VAS Center.

The fryer never reaches the temperature

Thermostat or thermostat failure requiring calibration.

frying.

Page 49 of the Frymaster CF user manual — OU
Page 49 · click to enlarge
Page 49

ATMOSPHERIC GAS FRYERS MASTER JET CHAPTER 6: OPERATOR-POSSIBLE TROUBLESHOOTING

6.4. Troubleshooting of the integrated filtering system

PROBLEM LIKELY CAUSES CORRECTIVE ACTION

A. If the pump is working normally

A. Overheating switch a

After re-arming the overheat switch, the pump overheated.

Disjuncture following overheating of the engine.

Always filter vegetable oil or fat at the cooking temperature or almost. Cool the pump engine for about 10 minutes after filtering two complete frying tanks one after another. Check the filter paper after filtering each frying basin. Replace the paper if a lot of sediment has accumulated. B. Micro-transmission of the handle

Test : If the pump stopped suddenly during filtering, especially if it was after several filter cycles, then the engine of the pump probably overheated. Place the filter handle on OFF position, let cool pump for at least 45 minutes and then press the rearming button of engine in pump. Try to activate the pump.

filter failed.

Test : If it is a multi-basin fryer, try using the pump by operating another handle. If the pump starts, the handle micro-switch is misaligned or inoperative. When the handle is placed on position ON, the micro-switch lever must be firmly pressed against the switch. If so, the switch is out of order. Otherwise, the switch is loosened and/or misaligned.

The pump doesn't start.

B. If the switch is loose, press

screws that hold it in place, ensuring that by placing the handle on ON, the micro-cwitch lever is pressed firmly against the switch.

OU

during filtering.

If the switch is down, call your Frymaster VAS center.

C. Pump locks are

C. Pump block.

The most common reason for this is the accumulation of sediment in the pump due to poor size or installation filter paper and lack of use of the crumb sieve. Call your Frymaster VAS center to unlock the pump.

Test : Close the drain valve. Place the filter handle on OFF position, let cool pump for at least 45 minutes and then press the rearming button of engine in pump. Remove the filter pan from the unit and activate the pump. If the pump motor snores and then stops, the pump is blocked.

Make sure the paper filter is of correct size and installed correctly, and that the crumb sieve is in place.

Pump stops

Page 50 of the Frymaster CF user manual — 6.4. Troubleshooting of the integrated filtering system (cont'd)
Page 50 · click to enlarge
Page 50

ATMOSPHERIC GAS FRYERS MASTER JET CHAPTER 6: OPERATOR-POSSIBLE TROUBLESHOOTING

6.4. Troubleshooting of the integrated filtering system (cont'd)

PROBLEM LIKELY CAUSES CORRECTIVE ACTION

A. To filter properly, oil or

vegetable fat must be at 177 oC or almost. At lower temperatures, oil or vegetable fat becomes too thick to pass easily through the filter, slowing back the oil and causing overheating of pump motor. Make sure that vegetable oil or fat is almost at cooking temperature before emptying it in the filter pan. B. Components of the filter tray

A. L-oil or vegetable fat is too much

cold for filtering.

installed or poorly prepared.

B. Remove oil from the filter pan and

replace the paper filter, making sure that the sieve is in place under paper.

Test : Close the drain valve. Place the filter handle on OFF, remove the filter tray (and Power Shower if applicable) from the device. Put the filter handle back on ON. If a powerful air current comes out of the oil return orifice (or from the Power Shower) then the problem is with filter pan components.

Pump starts, but no transfer takes place or transfers

If this is not enough to correct the problem, then the filter suction tube is probably blocked. To unload it, use a fine and flexible wire. If you don't get there, call your Frymaster VAS Center.

is very slow.

C. Make sure the joint(s) is

O-rings are present on the filter connection and in good condition.

C. Components of the filter tray

Replace the paper filter, making sure that the filter holder sieve is properly positioned under paper.

installed or poorly prepared (continued).

Page 51 of the Frymaster CF user manual — 6.5. Troubleshooting of the abnormal operation of burners
Page 51 · click to enlarge
Page 51

ATMOSPHERIC GAS FRYERS MASTER JET CHAPTER 6: OPERATOR-POSSIBLE TROUBLESHOOTING

6.4. Troubleshooting of the integrated filtering system (cont'd)

A. Bung openings or grease

solidified plant in the Power Shower.

A. Clean it in accordance with the

instructions in Chapter 5 of this manual.

Test : See if oil or grease is projected around the joint of Power Shower. If so, the Power Shower is blocked.

Power Shower

B. O-rings and seal

B. Make sure the O-rings are in place

- No, you don't spray properly.

worn or missing on the Power Shower.

and the seal is present in good condition.

C. Paper missing in the tray of

filter. (This causes too much pressure in oil return pipes, which produces a powerful flow through the Power Shower but also the oil projection around the seal.)

C. Make sure the paper filter

is properly installed in the bin.

6.5. Troubleshooting of the abnormal operation of burners

PROBABLE CAUSES CORRECTIVE MEASUREMENT The fryer works normally, but the flames exceed on

Turn off the fryer and clean the nozzle in accordance with the instructions on pages 5-4 and 5-5 of this manual.

Gas tap ventilation nozzle blocked.

The burner front.

Page 52 of the Frymaster CF user manual — 6.5. Troubleshooting of the abnormal operation of burners
Page 52 · click to enlarge
Page 52

ATMOSPHERIC GAS FRYERS MASTER JET CHAPTER 6: OPERATOR-POSSIBLE TROUBLESHOOTING

6.6. Replacement of controller or cable beam 1. Disconnect the fryer from the area. 2. Remove the two screws from the top corners of the control panel and open the board by tilting it from the upper corner, allowing it to lean on its hinge legs. 3. Disconnect the cable beam from the controller's rear and, if you replace the beam, disconnect it from the interface board (arrows). 4. If you replace the controller, disconnect the ground wire and 15 pin connector (arrows), then remove the controller by lifting it from hinge slots of the chassis on the control panel. 5. Inversely, install a new controller or cable bundle.

Frymaster CF — 6.5. Troubleshooting of the abnormal operation of burners diagram (page 52)
Fig. 39 · 6.5. Troubleshooting of the abnormal operation of bu…

If you replace the beam, disconnect it from the controller and interface card (arrows).

Frymaster CF — 6.5. Troubleshooting of the abnormal operation of burners diagram (page 52)
Fig. 40 · 6.5. Troubleshooting of the abnormal operation of bu…

If you replace the controller, disconnect the ground wire and 15 pin connector (arrows).

Page 53 of the Frymaster CF user manual — 6.5. Troubleshooting of the abnormal operation of burners
Page 53 · click to enlarge
Page 53
Page 53 of the Frymaster CF user manual — 6.5. Troubleshooting of the abnormal operation of burners
Page 54 of the Frymaster CF user manual — 1-800-551-8633 819-6019 NOVEMBRE 2003
Page 54 · click to enlarge
Page 54
Frymaster CF — 1-800-551-8633 819-6019 NOVEMBRE 2003 diagram (page 54)
Fig. 41
Frymaster CF — 1-800-551-8633 819-6019 NOVEMBRE 2003 diagram (page 54)
Fig. 42
Frymaster CF — 1-800-551-8633 819-6019 NOVEMBRE 2003 diagram (page 54)
Fig. 43
Frymaster CF — 1-800-551-8633 819-6019 NOVEMBRE 2003 diagram (page 54)
Fig. 44

Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, LA 71135-1000

Shipping address8700 Line Avenue, Shreveport, LA 71106 - United States

TEL 1-318-865-1711 FAX (Exhibits) 1-318)-688-2200 FAX (1-310-219-7135

Prices$14 PRINTED IN THE UNITED STATES TELEPHONE HOTLINE

1-800-551-8633 819-6019 NOVEMBRE 2003

Ask about the Frymaster CF

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster CF

Be the first to ask — other owners or our team will answer.

Original document

Frymaster CF manual PDF

54 pages·4 MB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…