NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
U.S. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.
CANADA This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications. Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.


Frymaster, L.L.C. makes the following limited warranties to the original purchaser only for this equipment and replacement parts:
B. WARRANTY PROVISIONS - FRYPOTS (Applies to fryers manufactured after December 1, 2003, only.)
If a frypot develops a leak within ten years after installation, Frymaster will, at its option, either replace the entire battery or replace the frypot, allowing up to the maximum time per the Frymaster time allowance chart hours of straight-time labor plus up to 100 miles/160 km of travel (50 miles/80 km each way) to change the frypot.

All defective in-warranty parts must be returned to a Frymaster Authorized Factory Service Center within 60 days for credit. After 60 days, no credit will be allowed.
This warranty does not cover equipment that has been damaged due to misuse, abuse, alteration, or accident such as: • improper or unauthorized repair (including any frypot which is welded in the field);
This warranty also does not cover: • transportation or travel over 100 miles/160 km (50 miles/80 km each way), or travel over two hours;
There are no implied warranties of merchantability or fitness for any particular use or purpose. This warranty is applicable at the time of this printing and is subject to change.


CHAPTER 1: INTRODUCTION
1.1 General Read the instructions in this manual thoroughly before attempting to operate this equipment. This manual covers all configurations of McDonald’s RE14 models. The fryers in this model family have most parts in common, and when discussed as a group, will be referred to as “RE14” fryers. Although similar in appearance to the PH14 McDonald’s electric fryers, the RE14 fryers feature a significantly different rotating element with an enhanced design. The Euro-Look design incorporates a rounded topcap and a large round drain, which ensures that fries and other debris, will be washed into the filter pan. Other features, including the deep cold-zones and easy to clean, open frypots remain essentially unchanged. The RE14 fryers are controlled with the M2000 computer. Fryers in this series come in full- or split-vat arrangements, and can be purchased as single units or in batteries of up to five fryers. 1.2 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the one below.
DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your system and/or cause your system to malfunction. Fryers in this series are equipped with the following automatic safety features: 1. Two high-temperature detection features shut off power to the elements should the temperature controls fail. 2. A safety switch built into the drain valve prevents the elements from heating with the drain valve even partially open.

1.3 Computer Information for the M2000 Computers
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense. The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. 1.4 European Community (CE) Specific Information The European Community (CE) has established certain specific standards regarding equipment of this type. Whenever a difference exists between CE and non-CE standards, the information or instructions concerned are identified by means of shadowed boxes similar to the one below.
CE Standard Example of box used to distinguish CE and
Non-CE specific information.
1.5 Installation, Operating, and Service Personnel Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.6. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6. 1.6 Definitions QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.

QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in person or through a representative, are engaged in and are responsible for the installation of electrical appliances. Qualified personnel must be experienced in such work, be familiar with all electrical precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qualified service personnel are those who are familiar with Frymaster equipment and who have been authorized by Frymaster, L.L.C. to perform service on the equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a minimum amount of parts for Frymaster equipment. A list of Frymaster Factory Authorized Service Centers (FASC) is included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Frymaster warranty on your equipment 1.7 Shipping Damage Claim Procedure What to do if your equipment arrives damaged: Please note that this equipment was carefully inspected and packed by skilled personnel before leaving the factory. The freight company assumes full responsibility for safe delivery upon acceptance of the equipment. 1. File Claim for Damages Immediately - regardless of extent of damage. 2. Inspect For and Record All Visible Loss or Damage, and ensure that this information is noted on the freight bill or express receipt and is signed by the person making the delivery. 3. Concealed Loss or Damage- If damage is unnoticed until equipment is unpacked, notify the freight company or carrier immediately upon discovery and file a concealed damage claim. This must be submitted within 15 days of date of delivery. Be sure to retain container for inspection.
Frymaster DOES NOT ASSUME RESPONSIBILITY FOR DAMAGE OR LOSS
INCURRED IN TRANSIT.

1.8 Service Information For non-routine maintenance or repairs, or for service information, contact your local Frymaster Authorized Service Center (FASC). In order to assist you quickly, the Frymaster Factory Authorized Service Center (FASC) or Service Department representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the fryer door. Part numbers are found in the Installation, Operation, Service, and Parts Manual. Parts orders may be placed directly with your local FASC or distributor. Included with fryers when shipped from the factory is a list of Frymaster FASCs. If you do not have access to this list, contact the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711 or by email at service@frymaster.com. The following information will be needed in order to assist you efficiently:
Model Number Serial Number Voltage Nature of the Problem
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.

2.1 General Installation Requirements Proper installation is essential for the safe, efficient, trouble-free operation of this appliance. Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6 of this manual, should perform all installation and service on Frymaster equipment. Failure to use qualified, licensed, and/or authorized installation or service personnel (as defined in Section 1.6 of this manual) to install or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel. Where conflicts exist between instructions and information in this manual and local or national codes or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed. Service may be obtained by contacting your local Factory Authorized Service Center.

DANGER Building codes prohibit a fryer with its open tank of hot oil being installed beside an open flame of any type, including those of broilers and ranges. In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power switch OFF. Do not attempt to start the fryer(s) until power is restored. This appliance must be kept free and clear of combustible material, except that it may be installed on combustible floors. A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for servicing and proper operation.
2.1.2 Electrical Grounding Requirements All electrically operated appliances must be grounded in accordance with all applicable national and local codes, and, where applicable, CE codes. A wiring diagram is located on the inside of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.


2.1.3 Australian Requirements To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations. 2.2 Power Requirements The three phase supply plug for the elements is rated at 60 amps, 250 VAC and is NEMA configuration L15-60P. The control and filter plug is rated at 20 amps, 120/208 VAC and is NEMA configuration L21-20P. Each fryer should have its cord for the element supply on an individual circuit as well as the control cord.
AWG (mm2) L1 L2 L3 208 3 3 6 (16) 39 39 39
MIN. SIZE
240 3 3 6 (16) 34 34 34
480 3 3 8 (10) 17 17 17
220/380 3 4 6 (16) 21 21 21
240/415 3 4 6 (16) 20 20 21
230/400 3 4 6 (16) 21 21 21
230/400 France Only 3 4 6 (16) 25 25 25
2.3 After Fryers Are Positioned At the Frying Station


To level fryers, adjust the casters being careful to ensure the fryer(s) are at the proper height in the frying station. When the fryer is leveled in its final position, install the restraints provided with the unit to limit its movement so that it does not depend on or transmit stress to the electrical conduit or connection. Install the restraints in accordance with the provided instructions (see illustration below). If the restraints are disconnected for service or other reasons, they must be reconnected before the fryer is used.

CHAPTER 3: OPERATING INSTRUCTIONS
FINDING YOUR WAY AROUND THE BIRE14 SERIES E4 ELECTRIC FRYER
Tilt Housing Basket Hangers


Control Panel (M2000 Computer shown)
Fryer Identification Data Labels (Model



Drain and Filter Handles
TYPICAL CONFIGURATION (BIRE214 SHOWN) Domestic NOTE: The appearance of your fryer may differ slightly from that shown depending upon the configuration and date of manufacture.

3.1 Equipment Setup and Shutdown Procedures
5. Ensure that the oil level is at the top OIL LEVEL line when the oil is at its cooking temperature. It may be necessary to add oil to bring the level up to the proper mark, after it has reached cooking temperature. Shutdown 1. Turn the fryer off or STANDBY. 2. Filter the oil and clean the fryers (See Chapters 4 and 5). 3. Place the frypot covers on the frypots. 3.2 Operation If this is the first time the fryer is being used, refer to the frypot boil-out procedure on Page 5-2. This fryer is equipped with M2000 computers (illustrated below). Refer to the separate M2000 Computer Operating Instructions furnished with the fryer for the computer programming and operating procedures.

M2000 COMPUTER Refer to Chapter 4 of this manual for operating instructions for the built-in filtration system.
Setup

CHAPTER 4: FILTRATION INSTRUCTIONS 4.1 Introduction The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in operation. Section 4.2 covers preparation of the filter system for use. Operation of the system is covered in section 4.3.

WARNING The on-site supervisor is responsible for ensuring that operators are made aware of the inherent hazards of operating a hot oil filtering system, particularly the aspects of oil filtration, draining and cleaning procedures. 4.2 Preparing the Filter for Use 1. Pull the filter pan out from the cabinet and remove the crumb tray, hold-down ring, filter pad (or paper), and filter screen. (See Figure 1) Clean all metal parts with a solution of All Purpose Concentrate and hot water then dry thoroughly.

The filter pan is equipped with rollers in rails, much like a kitchen drawer. The pan can be removed from the cabinet for cleaning by lifting the front of the pan to disengage the front rollers, then pulling it forward until the rear rollers clear the rails. The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (MSDU) to be positioned under the drain. If using an MSDU built before January 2004 see instructions on page 4-4. 2. Inspect the filter pan connection fitting to ensure that both O-rings are in good condition. (See Figure 2)


3. Then in reverse order, place the metal filter screen in the center of the bottom of the pan, then lay a filter pad over the screen, ensuring that the rough side of the pad is up. Make sure that the pad is in between the embossed ridges of the filter pan. Then position the hold down ring on top of the pad. If using filter paper, lay a sheet of filter paper over the top of the pan overlapping on all sides. Position the hold down ring over the filter paper and lower the ring into the pan, allowing the paper to fold up and around the ring as it is pushed to the bottom of the pan. Then sprinkle 1 packet (8-ounces) of filter powder over the filter paper. 4. Reinstall the crumb tray at the front of the pan. (See Figure 1)

Open the drain valves on the frypot
and drain the oil into the filter pan.


DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty.

Open valve by moving handle to the right.
Turn the filter handle to the ON position. 3. The filter pump draws the oil through the filter pad/paper and screen and circulates it back up to and through the frypot during a 5-minute process called polishing. Polishing cleans the oil by trapping solid particles in the filter pad.

Filter Pump Reset Switch 5. Lower the elements into the frypot and reinstall the basket support rack. 6. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not operate.) Turn the fryer ON and allow the oil to reach setpoint.

4.4 Draining and Disposing of Waste Oil When your cooking oil has reached the end of its usable life, drain the oil into an appropriate container for transport to the disposal container. Frymaster recommends the use of the McDonald’s Shortening Disposal Unit (MSDU). NOTE: If using an MSDU built before January 2004 the filter pan cover on must be removed to allow the unit to be positioned beneath the drain. To remove the lid, lift up on the front edge and pull it straight out of the cabinet. Refer to the documentation furnished with your disposal unit for specific operating instructions. If a shortening disposal unit is not available, allow the oil to cool to 100°F (38°C), then drain the oil into a metal stockpot or similar metal container. When draining is finished, close the fryer drain valve securely.


5.1.1 Clean Inside and Outside of the Fryer Cabinet – Daily Clean inside the fryer cabinet with a dry, clean cloth. Wipe all accessible metal surfaces and components to remove accumulated oil and dust. Clean the outside of the fryer cabinet with a clean, damp cloth soaked with McDonald’s All Purpose Concentrate. Wipe with a clean, damp cloth. 5.1.2 Clean the Built-in Filtration System – Daily
WARNING Never drain water into the filter pan. Water will damage the filter pump. There are no periodic preventive maintenance checks and services required for your FootPrint Pro Filtration System other than daily cleaning of the filter pan and associated components with a solution of hot water and McDonald’s All Purpose Concentrate. 5.1.3 Clean Behind Fryers – Weekly Clean behind fryers in accordance with the procedure detailed in maintenance requirement card (MRC14A).


5.1.4 Clean the Frypot and Heating Elements – Weekly

□ With the filter pan empty, place each oil return handle, one at a time, in the ON position.
Verify that the pump activates and that bubbles appear in the cooking oil.
□ Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify
proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot.
□ Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to
335°F (168°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all cooking oil to return to the frypot, indicated by bubbles in the cooking oil. Return the oil return handle to the OFF position. The frypot should have refilled in no more than 2 minutes and 30 seconds.

6.1 Introduction This section provides an easy reference guide to some of the common problems that may occur during the operation of this equipment. The troubleshooting guides that follow are intended to help correct, or at least accurately diagnose, problems with this equipment. Although the chapter covers the most common problems reported, you may encounter problems that are not covered. In such instances, the Frymaster Technical Services staff will make every effort to help you identify and resolve the problem. When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through to the most complex. Never overlook the obvious – anyone can forget to plug in a cord or fail to close a valve completely. Most importantly, always try to establish a clear idea of why a problem has occurred. Part of any corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections, too. If a fuse continues to blow, find out why. Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system. Before calling a service agent or the Frymaster HOTLINE (1-800-24-FRYER):

6.2 Troubleshooting 6.2.1 Computer and Heating Problems
A. Computer not turned on. A. Press the ON/Off switch to turn
the computer on.
B. This fryer has two cords: a
computer power cord and a main power cord. If the computer cord is not plugged in, the computer will not activate. Verify computer power cord is plugged in and that circuit breaker is not tripped. C. Computer has failed. C. Call FASC. D. Damaged computer wiring harness.
B. No Power to the fryer.
D. Call FASC No Display on
Computer.
E. If any component in the power
supply system (including the transformer and interface board) fail, power will not be supplied to the computer and it will not function. Determining which component has failed is beyond the scope of operator troubleshooting. Call FASC.
E. Power supply component or
interface board has failed.
A. A drain safety switch prevents
the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed. B. Computer has failed. B. Call FASC.
A. Drain valve is open.
C. This fryer has two cords: a
120V power cord and the main 3-phase power cord. If the 120V power cord is plugged in but the main power cord is not, the computer will appear to work normally, but the fryer will not heat. Verify that both the main power cord and 120V is fully seated in its receptacle, locked into place and that circuit breaker is not tripped.
Fryer does not heat.
C. Main power cord not plugged in.

Problem Probable Causes Corrective Action
D. If the circuitry in the fryer
control system cannot determine the frypot temperature, the system will not allow the element to be energized or will de-energize the element if it is already energized. If the contactor, element, or associated wiring fails, the element will not energize. Determining which specific component is malfunctioning is beyond the scope of operator troubleshooting. Call FASC.
D. One or more other components have failed.
previous page.
This fryer is equipped with a drain safety switch that prevents the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed. Fryer heats until high-limit trips with
Fryer does not heat
after filtering. Drain valve is open.
Call FASC.
Temperature probe or computer has failed.
heat indicator ON.
Contactor or computer has failed Call FASC.
without heat indicator ON.
The fact that the heat indicator is ON indicates that the computer is functioning properly and is calling for heat. The high-limit thermostat functions as a normally closed switch. If the thermostat fails, the "switch" opens and power to the elements is shut off. If the contactor fails to close, no power is supplied to the elements. Determining which component has failed is beyond the scope of operator troubleshooting. Call FASC.
The high-limit thermostat or contactor has failed.
ON.

6.2.2 Error Messages and Display Problems
M2000 computers may be programmed to display in either Fahrenheit or Celsius. Refer to the separate M2000 Computer Operation Manual for instructions on changing the display.
M2000 display is in wrong temperature scale (Fahrenheit or
Incorrect display option programmed.
Celsius).
This display will appear only if the fryer is in the non-dedicated mode and the frypot temperature rises 15° (8°C) or more above the programmed setpoint. This indicates a problem with the temperature control circuitry. Turn the fryer off and call FASC.
shows HI. Fryer is 15ºF (8ºC) above setpoint.
This in an indication of a malfunction in the temperature control circuitry, including a failure of the high-limit thermostat. Shut the fryer down immediately and call FASC.
Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).
shows HOT.
This display is normal when the fryer is first turned on and may appear for a short while if a large batch of frozen product is added to the frypot. If the display never goes out, the fryer is not heating. Shut the fryer down and call FASC.
M2000 display shows LOW TEMP.
Frypot temperature is between 180°F (82°C) and 315°F (157°C).
This indicates a problem within the temperature measuring circuitry that is beyond the scope of operator troubleshooting. Shut the fryer down and call FASC.
M2000 display shows PROBE
Problem with the temperature measuring circuitry including the probe.
FAILURE.
This indicates that the fryer is not heating. It is displayed if the fryer loses its ability to heat oil. It is also displayed when the oil temperature is above 450°F (232°C) and the high- limit thermostat has opened, halting the heating of the oil. Verify that the drain valves are fully closed. If this does not correct the problem, call your FASC.
M2000 display shows IGNITION
Open drain valve, failed computer, failed interface board, open high- limit thermostat.
FAILURE.
This is displayed only during a test of the high-limit circuit and indicates that the high-limit has opened properly.
M2000 display shows HI-LIMIT. Computer in high-limit test mode.
M2000 display · M2000 display

This is displayed only during a test of the high-limit circuit and indicates that the high-limit has failed. DO NOT OPERATE THE FRYER! Call FASC. M2000 display shows PROBE FAILURE with
M2000 display shows HI 2 BAD. Computer in high-limit test mode.
Damaged computer wiring harness or connector.
alarm sounding.
Drain valve not fully closed. Press the ON/OFF switch off, close the drain valve(s) completely, then press the ON/OFF switch on.
with alarm sounding. Heating indicator is on, but
no heat.
shows LOW TEMP, heating indicator
A. Failed computer. A. Call FASC.
cycles on and off
normally. B. Damaged computer wiring
harness. B. Call FASC.
Call FASC.
shows IGN failure and alarm sounds, but
Failed computer.
fryer operates normally (false
alarm).
Call FASC.
mode or some buttons do not
Failed computer.
actuate.
Heat indicator off upon initial startup.
Call FASC.
Failed computer.
sounding.

6.2.3 Filtration Problems
A. Verify that the power cord is
A. Power cord is not plugged in or
fully plugged in. If so, verify that circuit breaker is not tripped.
circuit breaker is tripped.
B. If the motor is too hot to touch
for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch.
B. Pump motor has overheated
causing the thermal overload switch to trip.
start.
C. Blockage in filter pump.
C. Pump blockages are usually
caused by sediment buildup in the pump due to improperly sized or installed filter components and failure to use the crumb screen. Call FASC.
Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If the pump motor hums for a short time then stops, the probable cause is blockage of the pump itself.
Blockage in filter pan suction tube.
The blockage may be caused by sediment buildup or, if solid shortening is used, solidified shortening in the tube. Use a thin, flexible wire to remove the blockage. If the blockage cannot be removed, call FASC.
but oil does not return to frypot and
Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If bubbling occurs, there is a blockage in the filter pan suction tube.
there is no bubbling
oil.
A. If using filter paper or pad
configuration, verify that filter screen is in bottom of pan with paper or pad on top of screen. Verify if using a pad that the rough side is facing up.
Filter pump runs, but oil return is very
A. Improperly installed filter pan
Verify that O-rings are present and in good condition on filter pan connection fitting.
components.
slow.
If using Magnasol filter assembly, verify that O-ring is present and in good condition on filter screen fitting.
Continued on following page.
Filter pump won't · Filter pump runs

B. In order to properly filter, the
oil should be at or near 350ºF (177ºC). At temperatures lower than this, the oil becomes too thick to pass through the filter medium easily, resulting in much slower oil return and eventual overheating of the filter pump motor. Make sure oil is at or near frying temperature before draining oil into filter pan.
B. Attempting to filter with oil that
previous page.
is not hot enough.
Continued from









Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 (Tech Support) 1-318-219-7135
1-800-551-8633 APRIL 2006
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No Display on Computer. | A. Computer not turned on. | A. Press the ON/Off switch to turn the computer on. | p.25 |
| No Display on Computer. | B. No Power to the fryer. | B. This fryer has two cords: a computer power cord and a main power cord. If the computer cord is not plugged in, the computer will not activate. Verify computer power cord is plugged in and that circuit breaker is not tripped. | p.25 |
| No Display on Computer. | C. Computer has failed. | C. Call FASC. | p.25 |
| No Display on Computer. | D. Damaged computer wiring harness. | D. Call FASC | p.25 |
| No Display on Computer. | E. Power supply component or interface board has failed. | E. If any component in the power supply system (including the transformer and interface board) fail, power will not be supplied to the computer and it will not function. Determining which component has failed is beyond the scope of operator troubleshooting. Call FASC. | p.25 |
| Fryer does not heat. | A. Drain valve is open. | A. A drain safety switch prevents the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed. | p.25 |
| Fryer does not heat. | B. Computer has failed. | B. Call FASC. | p.25 |
| Fryer does not heat. | C. Main power cord not plugged in. | C. This fryer has two cords: a 120V power cord and the main 3-phase power cord. If the 120V power cord is plugged in but the main power cord is not, the computer will appear to work normally, but the fryer will not heat. Verify that both the main power cord and 120V is fully seated in its receptacle, locked into place and that circuit breaker is not tripped. | p.25 |
| Continued from previous page. | D. One or more other components have failed. | D. If the circuitry in the fryer control system cannot determine the frypot temperature, the system will not allow the element to be energized or will de-energize the element if it is already energized. If the contactor, element, or associated wiring fails, the element will not energize. Determining which specific component is malfunctioning is beyond the scope of operator troubleshooting. Call FASC. | p.26 |
| Fryer does not heat after filtering. | Drain valve is open. | This fryer is equipped with a drain safety switch that prevents the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed. | p.26 |
| Fryer heats until high-limit trips with heat indicator ON. | Temperature probe or computer has failed. | Call FASC. | p.26 |
| Fryer heats until high-limit trips without heat indicator ON. | Contactor or computer has failed | Call FASC. | p.26 |
| Fryer stops heating with heat indicator ON. | The high-limit thermostat or contactor has failed. | The fact that the heat indicator is ON indicates that the computer is functioning properly and is calling for heat. The high-limit thermostat functions as a normally closed switch. If the thermostat fails, the "switch" opens and power to the elements is shut off. If the contactor fails to close, no power is supplied to the elements. Determining which component has failed is beyond the scope of operator troubleshooting. Call FASC. | p.26 |
| M2000 display is in wrong temperature scale (Fahrenheit or Celsius). | Incorrect display option programmed. | M2000 computers may be programmed to display in either Fahrenheit or Celsius. Refer to the separate M2000 Computer Operation Manual for instructions on changing the display. | p.27 |
| M2000 display shows HI. | Fryer is 15ºF (8ºC) above setpoint. | This display will appear only if the fryer is in the non-dedicated mode and the frypot temperature rises 15° (8°C) or more above the programmed setpoint. This indicates a problem with the temperature control circuitry. Turn the fryer off and call FASC. | p.27 |
| M2000 display shows HOT. | Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC). | This in an indication of a malfunction in the temperature control circuitry, including a failure of the high-limit thermostat. Shut the fryer down immediately and call FASC. | p.27 |
| M2000 display shows LOW TEMP. | Frypot temperature is between 180°F (82°C) and 315°F (157°C). | This display is normal when the fryer is first turned on and may appear for a short while if a large batch of frozen product is added to the frypot. If the display never goes out, the fryer is not heating. Shut the fryer down and call FASC. | p.27 |
| M2000 display shows PROBE FAILURE. | Problem with the temperature measuring circuitry including the probe. | This indicates a problem within the temperature measuring circuitry that is beyond the scope of operator troubleshooting. Shut the fryer down and call FASC. | p.27 |
| M2000 display shows IGNITION FAILURE. | Open drain valve, failed computer, failed interface board, open high- limit thermostat. | This indicates that the fryer is not heating. It is displayed if the fryer loses its ability to heat oil. It is also displayed when the oil temperature is above 450°F (232°C) and the high- limit thermostat has opened, halting the heating of the oil. Verify that the drain valves are fully closed. If this does not correct the problem, call your FASC. | p.27 |
| M2000 display shows HI-LIMIT. | Computer in high-limit test mode. | This is displayed only during a test of the high-limit circuit and indicates that the high-limit has opened properly. | p.27 |
| M2000 display shows HI 2 BAD. | Computer in high-limit test mode. | This is displayed only during a test of the high-limit circuit and indicates that the high-limit has failed. DO NOT OPERATE THE FRYER! Call FASC. | p.28 |
| M2000 display shows PROBE FAILURE with alarm sounding. | Damaged computer wiring harness or connector. | Call FASC | p.28 |
| M2000 display shows IGN Failure with alarm sounding. Heating indicator is on, but no heat. | Drain valve not fully closed. | Press the ON/OFF switch off, close the drain valve(s) completely, then press the ON/OFF switch on. | p.28 |
| M2000 display shows LOW TEMP, heating indicator cycles on and off normally. | A. Failed computer. | A. Call FASC. | p.28 |
| M2000 display shows LOW TEMP, heating indicator cycles on and off normally. | B. Damaged computer wiring harness. | B. Call FASC. | p.28 |
| M2000 display shows IGN and failure alarm sounds, but fryer operates normally (false alarm). | Failed computer. | Call FASC. | p.28 |
| Computer will not go into program mode or some buttons do not actuate. | Failed computer. | Call FASC. | p.28 |
| Heat indicator off upon initial startup. Display shows or with alarm sounding. | Failed computer. | Call FASC. | p.28 |
| Filter pump won't start. | A. Power cord is not plugged in or circuit breaker is tripped. | A. Verify that the power cord is fully plugged in. If so, verify that circuit breaker is not tripped. | p.29 |
| Filter pump won't start. | B. Pump motor has overheated causing the thermal overload switch to trip. | B. If the motor is too hot to touch for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch. | p.29 |
| Filter pump won't start. | C. Blockage in filter pump. Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If the pump motor hums for a short time then stops, the probable cause is blockage of the pump itself. | C. Pump blockages are usually caused by sediment buildup in the pump due to improperly sized or installed filter components and failure to use the crumb screen. Call FASC. | p.29 |
| Filter pump runs but oil does not return to frypot and there is no bubbling oil. | Blockage in filter pan suction tube. Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If bubbling occurs, there is a blockage in the filter pan suction tube. | The blockage may be caused by sediment buildup or, if solid shortening is used, solidified shortening in the tube. Use a thin, flexible wire to remove the blockage. If the blockage cannot be removed, call FASC. | p.29 |
| Filter pump runs, but oil return is very slow. | A. Improperly installed filter pan components. | A. If using filter paper or pad configuration, verify that filter screen is in bottom of pan with paper or pad on top of screen. Verify if using a pad that the rough side is facing up. Verify that O-rings are present and in good condition on filter pan connection fitting. If using Magnasol filter assembly, verify that O-ring is present and in good condition on filter screen fitting. | p.29 |
| Filter pump runs, but oil return is very slow. | Continued on following page. | p.29 | |
| Continued from previous page. | B. Attempting to filter with oil that is not hot enough. | B. In order to properly filter, the oil should be at or near 350ºF (177ºC). At temperatures lower than this, the oil becomes too thick to pass through the filter medium easily, resulting in much slower oil return and eventual overheating of the filter pump motor. Make sure oil is at or near frying temperature before draining oil into filter pan. | p.30 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.