GAS FRYERS
This equipment chapter is to be installed in the Fryer Section of the
FOR YOUR SAFETY Do Not Store or use gasoline or
Equipment Manual.
other flammable vapors and liquids in the vicinity of this or any
other appliance.




1-800-24 FRYER FAX: 1-318-219-7135

Frymaster, L.L.C. 8700 Line Avenue 71106, 5489 Campus Drive 71129
P.O. Box 51000, Shreveport, Louisiana 71135-1000 TEL 318-865-1711 FAX (Parts) 318-219-7140 (Tech Support) 318-219-7135
PRINTED IN THE UNITED STATES SERVICE HOTLINE MAY 2006 1-800-24-FRYER www.frymaster.com E-mail: service@frymaster.com *8196094*

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.

DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all times when the fryer is in use.
DANGER This product contains chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.

Frymaster, L.L.C. makes the following limited warranties to the original purchaser only for this equipment and replacement parts:
B. WARRANTY PROVISIONS - FRYPOTS (Applies to fryers manufactured after December 1, 2003, only.)
1. Frymaster warrants the frypot assembly for ten years parts and labor. Components attached to the frypot, such as the high-limit, probe, gaskets, seals, ignitors and related fasteners, are also covered by the ten-year warranty if replacement is necessitated by the frypot replacement. Components that are not part of the frypot assembly, such as the blower, gas valve, micro switches, doors and cabinetry are not covered by the frypot warranty. If the frypot is found to be defective, Frymaster will replace the frypot, allowing up to the maximum time per the Frymaster time allowance chart hours of straight-time labor plus up to 100 miles/160 km of travel (50 miles/80 km each way) to change the frypot. 2. This warranty is limited to fryers operating on natural or propane (LP) gas. Fryers that operate on manufactured gas (also known as town gas or high-hydrogen gas) have a lifetime frypot warranty, parts only.
(Applies to fryers installed on or after November 1, 1994, only.)

All defective in-warranty parts must be returned to a Frymaster Authorized Factory Service Center within 60 days for credit. After 60 days, no credit will be allowed.
This warranty does not cover equipment that has been damaged due to misuse, abuse, alteration, or accident such as: • improper or unauthorized repair (including any frypot which is welded in the field);
This warranty also does not cover: • transportation or travel over 100 miles/160 km (50 miles/80 km each way), or travel over two hours;
There are no implied warranties of merchantability or fitness for any particular use or purpose. This warranty is applicable at the time of this printing and is subject to change.





CHAPTER 1: SERVICE PROCEDURES
BIPH52/55 and MPH52/55 Series gas fryers contain a welded stainless steel frypot that is directly heated by a high efficiency infrared burner system requiring approximately 43% less energy than conventional burners to cook the same volume. Self-contained combustion chambers (referred to as “burners”) are fitted into rails attached to the sides of the frypot, one on each side. Each combustion chamber is fitted with special ceramic tiles that are heated by the burning of a forced air/gas mixture. The tiles transfer heat to the frypot by means of infrared radiation, providing much more constant and uniform heat dispersion over the surface of the frypot than do conventional burners. Because less heat is lost to the atmosphere in the process, compared to “open-burner” designs, less fuel is required to achieve and maintain a given frypot temperature. In full-vat units, gas flow to both of the burners is regulated by one electromechanical gas valve. In dual-vat units, each burner has its own valve. All fryers in this series are equipped with 24 VAC gas valve systems, and all are configured with electronic ignition. 1.1.1 The Electronic Ignition System An ignition module mounted in the component box (located behind the control panel) is connected to an ignitor assembly at the burner. The ignition module performs four important functions: it provides fuse protection for the 24-volt circuit, provides an ignition spark, supplies voltage to the gas valve, and proofs the burner flame. The module contains a 4-second time delay circuit and a coil that activates the gas valve. Three types are in use. A closed-box design is used in most fryers, but in some fryers built for export the module resembles an interface board. A single dual-spark module is used on current production full-vat fryers. All dual-vat fryers use two single-spark modules. The ignitor assembly consists of a spark plug, an enrichment tube, and a flame sensor. At start-up, the power switch is placed in the ON position, supplying approximately 12-volts DC to the heat-control circuitry in the controller or computer and to one side of the heat relay coils on the interface board. If resistance in the temperature probe indicates the temperature in the frypot is below 180ºF (82ºC), the current flows through a melt cycle circuit where a timer switch alternately closes for 6 seconds and opens for 24 seconds. If the temperature is 180ºF (82ºC) or above, the current flows through a heat circuit, bypassing the timer switch. In either case, ground is supplied to the other leg of the heat relay coils, which then close electronic switches in the 24 VAC circuit to
Inside the Ignition Module
Out to Gas Valve
TD
HV
GND
Ignition Wire Flame Sensor
To Alarm · Coil

provide current to the ignition module. Circuitry in the ignition module sends 24 VAC to the gas valve via a normally closed high-limit switch (and, in fryers with built-in filtration systems, a normally closed drain safety switch). Simultaneously, the module causes the ignitor to spark for 4 seconds to light the burner. A flame sensor verifies the burner ignition by measuring the flow of microamps through the flame. If the burner does not light (or is extinguished), current to the ignition module is cut, the gas valve closes, and the ignition module “locks out” until the power switch is turned off and then back on. A probe monitors the temperature in the frypot. When the programmed setpoint temperature is reached, resistance in the probe causes the heat cycle circuitry in the controller to cut off current flow through the heat relay. This in turn cuts off the 24 VAC to the ignition module, causing the gas valve to close. 1.1.2 Interface Board All fryers in this series have an interface board located in the component box behind the control panel. The interface board provides a link between the controller/computer and the fryer’s individual components without requiring excessive wiring, and allows the controller to execute commands from one central point. This standard interface board is also used in a number of fryer types besides the BIPH52/55 and MPH52/55 Series. The information contained in this section applies to BIPH52/55 and MPH52/55 Series applications ONLY. K2 and K3 are double-pole-double throw (dpdt) relays that supply 24VAC to the ignition and gas valve circuits, as well as 120VAC to the blower motor. The relays on this board plug into sockets. If a relay fails, that relay can be replaced. LEDs (labeled D1 through D7) are arrayed around the board to assist in troubleshooting.


NOTE: Although the printing on some boards may indicate 2 Amp fuses, 3 Amp fuses (P/N 807-3843) must be used. In full-vat fryers, the relay for the left side (K2) may not be present. The chart on the following page illustrates current flow through the board, and the table at the top of page 1-4 identifies frequently used test points.


* ** Dual Vat configurations ** Full Vat configurations
MOD 25V TERM J3 PIN 8 via RT HT RELAY
CURRENT FLOW THROUGH INTERFACE BOARD
106-0386SP (BIPH52/55 and MPH52/55 SERIES APPLICATION)

servicing.

OFF 2. Remove the pressure tap plug from the gas valve assembly.
Typical Non-CE Valve Assembly

CE Standard Burner Manifold Gas Pressures
Vat Natural Gas Lacq (G20) under 20 mbar 7 7
Natural Gas Gronique * (G25) under 25 mbar 10 10
Natural Gas Gronique (G25) under 20 mbar 10 10
Butane/Propane (G30) at 28/30 or 50 mbar 17 17
Propane (G31) under 37 or 50 mbar 20 20
* Belgian G25 = 7,0 mbar (single or dual)
Non-CE Standard Burner Manifold Gas Pressures
Natural 3" W.C. 0.73 kPa
Propane 8.25" W.C. 2.5 kPa

7. Place the fryer power switch (and the gas valve in non-CE fryers) in the OFF position. Remove the fitting from the pressure tap hole and reinstall the pressure tap plug. 1.5 Measuring Flame Current When the burner flame is properly adjusted, it will produce a current between 2.5 μA and 3.5 μA. Flame current is measured by placing a microamp (not milliamp) meter in series with the sensing wire on the ignitor. This is accomplished as follows: 1. Place the fryer power switch in the OFF position. 2. Disconnect the sensing wire from one of the burner ignitors and connect it to the positive lead of the meter. Connect the negative lead of the meter to the terminal from which the sensing wire was removed.


1. Disconnect the fryer from the electrical power supply. 2. The controller bezel is held in place by tabs at the top and bottom. Slide the bezel up to disengage the lower tabs. Then slide the bezel down to disengage the upper tabs. 3. Remove the top two screws in the upper corners of the control panel. 4. Hinge the controller down. Allow it to rest on its hinge tabs to access the 15-pin connector on the back. 5. Disconnect the 15-pin wiring harness from the back of the controller and, if replacing the harness, disconnect it from the interface board. 6. Use a 5/16” nut driver (P/N 802-0352) to remove the nut and green ground wire from the back of the controller.
Flame Sensor Wire · (Right Burner)

7. Remove the controller by lifting it up and out from the hinge slots in the control panel frame. 8. Re-hinge the NEW controller by inserting the tabs on the bottom into the slots on the control panel frame and allow it to rest on the hinge tabs. 9. If replacing the 15-pin connector, do so now. Plug the new 15-pin wiring harness into the interface board ensuring the black ferrite metal ring is on the controller-end of the wire harness. 10. Connect the 15-pin connector and the green ground wire to the new controller. When the connector is completely engaged, the clips on either side of the connector will snap into place. 11. Move the controller into the closed position against the control panel frame and replace the screws in the top corners. 12. Insert the top tabs on the bezel into the slots on the underside of the top cap. Slide the bezel down to engage the lower tabs in the lower slots. 1.6.2 Replacing the Temperature Probe or High-Limit Thermostat 1. Disconnect the fryer from the electrical supply. 2. Drain cooking oil below the level of the probe or thermostat. 3. Lift up on the bezel to disengage the tabs on its lower edge from the control panel frame. 4. Remove the top two screws in the upper corners of the control panel. 5. Swing the controller out from the top and allow it to rest on its hinge tabs. 6. Disconnect the controller wiring harness and ground wire from the back of the controller and remove the controller by lifting it from the hinge slots in the control panel frame. 7. If the fryer has a built-in filtration system, remove the clevis securing the oil return handle to the oil return operating rod and separate the rod from the handle. 8. Disconnect the ignition cables from the ignitors by grasping the boots and gently pulling toward you. 9. Disconnect the flame sensor wires from the flame sensors. 10. Disconnect the sound device lead from the interface board. 11. If working on the left frypot, cut the wire tie on the wiring bundle and disconnect the main wiring harness 15-pin connector. 12. Remove the component box mounting screws.

13. Rotate the top of the component box out of the frame and carefully pull it out enough to disconnect the wiring harness plug from the back of the box. If the unit is equipped with built-in filtration, disconnect the wires from the filter switch. This will leave one set of wires, enclosed in spiral wrap, connected to the component box. 14. Remove the box and set it atop the fryer to expose the temperature probe and high-limit thermostat. 15. Cut the leads of the probe or thermostat, as appropriate, near the component and unscrew it from the frypot. 16. Apply Loctite® PST56765 pipe thread sealant or equivalent to the replacement part threads and screw the replacement part into the frypot, torquing to 180 inch-pounds. 17. Unscrew and remove the temperature probe (or high-limit thermostat) from the frypot. 18. Connect the wires from the new component as follows:
a. If replacing the temperature probe, use a pin pusher to disconnect (one at a time) the red and
white leads from the connector and insert the corresponding leads from the new probe.
b. If replacing the high-limit thermostat, use a pin pusher to disconnect the lead running to the
connector and insert the corresponding lead from the new thermostat. Disconnect the other lead from the drain safety switch and connect the remaining lead from the new thermostat. 19. Reverse steps 1 through 14 to complete the procedure. 1.6.3 Replacing the Interface Board
1. Disconnect the fryer from the electrical power supply. 2. The controller bezel is held in place by tabs at the top and bottom. Slide the bezel up to disengage the lower tabs. Then slide the bezel down to disengage the upper tabs. 3. Remove the top two screws in the upper corners of the control panel. 4. Hinge the controller down. Allow it to rest on its hinge tabs to access the 15-pin connector on the back. 5. Disconnect the 15-pin wiring harness from the back of the controller and from the interface board. 6. Use a 5/16” nut driver (P/N 802-0352) to remove the nut and green ground wire from the back of the controller. 7. Remove the controller by lifting it up and out from the hinge slots in the control panel frame. 8. Disconnect the wires attached to the interface board, marking or making a note of the wires and terminals to facilitate reconnection.

9. Remove the nuts at each corner of the interface board and carefully pull it from the studs far enough to allow the connector on the back of the board to be disconnected, then remove the board from the box. When removing the board, be careful not to lose the spacers that fit over the studs behind the board. 10. Recover the relay(s) from the failed interface board and install on the replacement board. 11. Reverse the procedure to install the replacement board, being sure that the spacers behind the board are in place. 1.6.4 Replacing an Ignition Module
1. Disconnect the fryer from the electrical supply. 2. Lift up on the bezel to disengage the tabs on its lower edge from the control panel frame. 3. Remove the top two screws in the upper corners of the control panel. 4. Swing the controller out from the top and allow it to rest on its hinge tabs. 5. Disconnect the wires from the ignition module, marking or making a note of the wires and terminals to facilitate reconnection. 6. Remove the four ignition module screws and pull the module from the component box. 7. Move the spacers to the new module. 8. Reverse the procedure to install the replacement module. 1.6.5 Replacing an Ignitor Assembly
DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect the fryer from the electrical supply. 2. Disconnect the flame sensor wire by carefully pulling its push-on terminal from the terminal strip on the ignitor. Disconnect the gas enrichment tube at the ignitor-end compression fitting. Disconnect the ignition cable from the ignitor by grasping its boot and gently pulling toward you. (See photo on the following page)


Flame Sensor Wire Gas Enrichment Tube Ignition Cable

Wiring connection Blower assembly


mounting nuts

Remove these screws to remove the shield from the blower assembly.
Remove these nuts to separate the blower motor from the housing.
Wrap the motor and wires
with plastic wrap or a
plastic bag.
Blower Housing · Blower Wheel


Left Viewing Port is behind
motor.
Port.

The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the applicable table on page 1-6 and the burners display a bright orange-red glow. If a blue flame is observed or if there are dark spots on a burner face, the air/gas mixture requires adjustment.
On the side of the blower housing opposite the motor is a shutter plate with a locking nut. Loosen the nut enough to allow the shutter to be moved, then adjust the position of the shutter to open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the shutter in position and tighten the locking nut.
Loosen this nut and rotate shutter to open or close air intake.
Right Viewing

DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect fryer from electrical and gas supplies. 2. Disconnect the drain safety and high-limit thermostat wires from the gas valve. Mark each wire to facilitate reconnection. 3. Remove the vent tube (on non-CE fryers) and the enrichment tube fitting from the valve. Disconnect the flexible gas line(s). If replacing the left-most valve on any configuration, or the right valve on a two-fryer battery, follow the instructions below. If replacing valves in other positions, skip to “ALL OTHER VALVES.” A. Remove the filter pan from the unit. Remove the door adjacent to the valve being replaced. B. Remove the five screws on the front face of the pan rail assembly adjacent to the valve being
replaced. Remove the nut and bolt securing the rear end of the rail to the cabinet. C. Remove the two nuts and bolts immediately behind the front face of the pan rail assembly. Pull
the assembly from the unit to gain access to the pipe union on the gas line. D. Uncouple the pipe union and remove the gas valve and associated piping from the unit. E. Remove the fittings and associated piping from the failed valve and install them on the
replacement valve using Loctite® PST56765 or equivalent pipe thread sealant. F. Reconnect the gas valve assembly to the fryer using Loctite® PST56765 or equivalent pipe
thread sealant, and reattach the flexible gas line(s), enrichment tube(s), and the vent tube (on non-CE units). Reconnect the high-limit thermostat wires and drain safety wires to the valve. G. Reconnect the fryer to the gas supply and open the cut off valve. Apply a solution of soapy
water around each connection to check for gas leaks. Eliminate any that are found. H. Position the pan rail assembly beneath the fryer and rest the rear end of the rail on the cabinet
frame. Install the two nuts and bolts behind the front face of the rail, but do not tighten them. Install the nut and bolt at the rear end of the filter rail and tighten securely. I. Install the five screws in the front face of the rail, but do not tighten them. Install the filter pan
in the unit to make sure that all components are properly aligned; then, securely tighten the remaining bolts and screws. J. Reconnect the fryer to the electrical power supply and check for proper operation. When proper
operation has been verified, reinstall the door removed in Step A.

ALL OTHER VALVES 4. Carefully unscrew the valve from the manifold. NOTE: Some models may have the valve attached to the manifold by means of a pipe union. In such cases, remove the valve by uncoupling the union. 5. Remove all fittings from the old gas valve and install them on the replacement valve, using Loctite® PST56765 or equivalent pipe thread sealant. 6. Reconnect the gas valve assembly to the fryer using Loctite® PST56765 or equivalent pipe thread sealant, and reattach the flexible gas line(s), enrichment tube(s), and the vent tube (on non-CE units). Reconnect the high-limit thermostat wires and drain safety wires to the valve. 7. Reconnect the fryer to the gas supply and open the cut off valve. Apply a solution of soapy water around each connection to check for gas leaks. Eliminate any that are found. 8. Reconnect the fryer to the electrical power supply and check for proper operation. 1.6.8 Replacing a Burner Assembly
NOTE: If the flexible oil return lines are blocking the plenum, carefully bend them upward enough to clear the plenum. 4. Disconnect the ignition cable from the ignitor by grasping its boot and pulling gently toward you. Disconnect the flame sensor wire from the ignitor by gently pulling its push-on terminal from the terminal strip on the ignitor. 5. Disconnect the flexible gas lines from the burner orifice and the enrichment tube from the ignitor assembly. 6. Remove the four ¼-inch nuts securing the outer front covers to the frypot assembly. 7. Remove the sheet metal screws at the top of the outer front covers and pull the covers straight out toward you until clear of the mounting studs.

a. If the welds in the lower rail are cracked or burned out, the frypot must be replaced. Refer to
Section 1.6.10 for procedure. b. If the welds in the upper rail are cracked or burned out, the upper rail must be replaced.
Refer to Section 1.6.11 for procedure. 12. Place a new insulating strip along the top, rear, and bottom edge of the burner and carefully slide it straight into the rails. NOTE: Use P/N 826-0931 for full-vat frypots and P/N 826-0932 for dual-vat frypots. 13. Reverse steps 1 through 9 to reassemble the components. 14. Fill the frypot with oil. Turn the fryer on, turn off or bypass the melt cycle, and operate the unit for at least 10 minutes. 15. Visually examine the burner flame. The color and intensity on both sides should be the same. 16. Use an inspection mirror to check for leaks in areas that cannot be directly observed. 17. If a leak is detected, tighten all the lower insulation retainer nuts, allow the frypot to run for five additional minutes, and repeat steps 15 and 16. 18. If the leak persists, use a rubber hammer and a small block of wood to tap the corners of the lower combustion chamber insulation retainers. Repeat steps 15 through 17. Repeat this step until no leakage is detected. 1.6.9 Replacing the Filter Motor, Filter Pump, or Filter Pump Solenoid Valve

at one time. 3. Position a container beneath the oil return fitting at the front of the cabinet. Disconnect the flexible oil line from the fitting, allowing any residual oil to drain into the container. 4. At the rear of the fryer, unplug the left connector (as viewed from the rear of the fryer) from the transformer box. Using a pin pusher, push the pump solenoid valve wires from Pins 7 and 9. 5. Remove the four nuts and bolts attaching the motor mount to the rear motor mount support. 6. At the front of the fryer, remove the cover plate from the front of the motor and disconnect the motor wires. 7. Place a 1-foot (30.5-cm) length of wood (or similar support) beneath the motor mount near the front of the unit and remove the two remaining nuts and bolts attaching the motor mount to the front cabinet cross-brace. 8. Carefully remove the support and lower the motor mount to the floor, allowing the rear of the mount to slide forward and off the rear motor mount support. 9. Disconnect the return flexline from the pump. The motor and pump assembly can now be pulled from beneath the fryer and the failed component can be removed and replaced. 10. Position the new/repaired motor and pump assembly beneath the fryer and reconnect the oil return flexline to the pump. Lift the rear of the motor mount up and onto the rear motor mount support. 11. Lift the front of the motor mount up and support it with a 1-foot (30.5-cm) piece of wood or a similar support. Install but do not tighten the two nuts and bolts that attach the motor mount to the front cabinet cross-brace. 12. Install and tighten the four nuts and bolts that secure the motor mount to the rear motor mount support. Reconnect the solenoid valve wires to Pins 7 and 9 of the 9-pin connector (polarity does not matter) and reconnect the plug. 13. At the front of the fryer, tighten the two nuts and bolts at the front of the motor mount. Reconnect the motor power wires and reinstall the wiring cover plate. 14. Reconnect the oil return flexline and reinstall the filter pan. 15. Reconnect the unit to the electrical power supply, fill the frypots with oil and check for proper operation. 1.6.10 Replacing the Frypot

at one time. 3. Dismount the topcap by removing the screws on the bottom of each front corner and lifting the topcap straight up. 4. Remove the bezels by lifting them up to disengage the tabs along the lower edges from the slots in the control panel frame. Remove the top two screws in the upper corners of the control panel. 5. Grasp the upper edge of each controller and swing the controller downward. Unplug the controller wiring harness and grounding wire from the back of each controller. 6. Remove the controllers by lifting them from the hinge slots in the control panel frame. 7. Remove the clevis that secures the oil return rod to the oil return handle and separate the rod and handle. NOTE: On split-vat units, there are two oil return handles. 8. Disconnect the sound device wire from the interface board and disconnect the oil return switch wires from the switch terminals. 9. Disconnect the flame sensor wires by carefully pulling the push-on terminals from the terminal strips on the ignitors. Disconnect the gas enrichment tube at the ignitor-end compression fitting. Disconnect the ignition cables from the ignitors by grasping the boots and gently pulling toward you. 10. Remove the two mounting screws on each side of the component box and rotate the top of the box out of the frame. Carefully pull it out enough to disconnect the wiring harness connector from the back of the box. Cut any ties that prevent the box from being pulled out of the control panel frame. 11. Carefully pull the box clear of the frame and rest it atop the fryer. 12. Using a pin pusher, remove the temperature probe and high-limit thermostat wires from the plugs or terminals, marking each wire to facilitate re-assembly. 13. Remove the cover from the safety drain switch. Disconnect the wires from the switch. 14. Remove the section(s) of drain from the drain valve(s) of the frypot to be removed. 15. Disconnect the gas lines from the burner orifices and ignitor assemblies. 16. Remove the frypot hold down bracket.

17. Remove the screws in the back panel and inside the flue cap at each end that secure the flue cap to the fryer and lift it clear of the fryer. 18. Disconnect the oil return line(s) from the frypot to be removed. 19. Carefully lift the frypot from the fryer cabinet. 20. Remove the drain valve(s), temperature probe(s), high-limit thermostat(s), and ignitor assemblies. Inspect each of these components carefully and install them in the replacement frypot if they are in serviceable condition. Use Loctite® PST56765 sealant or equivalent on component threads.
NOTE: Some servicers, based upon their experience, recommend that probes and thermostats be replaced whenever a frypot is replaced; however, this remains the customer’s decision. 21. Reverse steps 1-19 to reassemble fryer. NOTE: Care should be taken not to over-torque nuts on frypots made of 400-series stainless steel, as this could tear the material. One turn past hand-tight is sufficient torque. 22. Perform steps 14 through 18 of Section 1.6.8 to ensure that there are no leaks in the burner insulation.
NOTE: Replacing the burner rails requires completely tearing down the frypot and installing new frypot insulation. Refer to the frypot exploded view on page 1-21 for component identification. 1. Remove the frypot per Section 1.6.10. 2. Remove the burner assemblies (1). 3. Remove insulation retainers and blanket insulation (2). 4. Remove the upper oil zone insulation bracket and upper oil zone insulation (3). 5. Remove the plenum (4). 6. Remove the front lower combustion chamber insulation retainer and insulation (5), and the front lower combustion chamber inner insulation retainer and insulation (6). NOTE: Full-vat units have two-piece insulation retainer and insulation components. Dual-vat units have one-piece components. 7. Remove the upper combustion chamber insulation retainer and insulation (7).


(Full Vat Illustrated)
Spacer · Spacers

11. Remove the upper burner rails (11). NOTE: For the following steps, refer to the frypot exploded view on page 1-24 for component identification. 12. Remove any residual insulation, sealant, and/or oil from the exterior of the frypot. 13. Place the “L” shaped pieces of the combustion chamber insulation (1) in the front and rear corners of both upper rail-retaining slots. (See page 1-24). 14. Using a mallet and short piece of wood, tap the corner tabs of the combustion chamber over the insulation to ensure a solid seal of the burner. 15. Install the upper burner rails (2) with the heat deflectors slanting toward the rear of the frypot. The rails will cover the “L” shaped pieces of combustion chamber insulation previously installed. 16. Place the upper inner combustion chamber insulation and insulation retainers (3) on the top two studs on each side of the front of the frypot and secure with ¼”-20 washer-nuts. It is normal for the retainers to slice off the overhanging insulation. 17. Place the lower rear combustion chamber insulation (4) on the lower four studs at the rear of the frypot. 18. Place one 1.625-inch tubular spacer (5) on each of the flue assembly (upper) studs at the rear of the frypot. NOTE: There are three different sizes of spacers. Verify the size to ensure the correct spacers are installed. 19. Press the flue assembly (6) over the burner rails. It may be necessary to use a rubber mallet or screwdriver to align the components. Use four ¼”-20 washer nuts to secure the flue assembly. Do not tighten the retainer nuts at this point. They should be finger-tight only. NOTE: The flue edge will cover one to two inches of the lower insulation. 20. Install the lower rear combustion chamber back(s) and retainer(s) (7) with the flanged edge(s) against the flue. Secure with ¼”-20 washer nuts. NOTE: Full-vat units have two-piece backs and four retainers. Dual-vat units come with one-piece backs and only two retainers. 21. Insert the burners (9) into the rails to ensure the rail spacing and alignments are correct. The burner should slide freely into and out of the rails. The upper rail can be bent slightly to increase or decrease tension on the burner and the edges of the slot can be closed or opened slightly to best fit the burner frame. 22. Carefully wrap a strip of burner insulation (8) tightly around the rear and sides of the burner frame (9), with the glass-tape side of the strip on the outside. Do not use duct tape or adhesive to secure the strip to the burner frame. 23. Align the burner to the burner rails while maintaining tension on the insulation strip. Insert the burner at a slight angle and begin pushing the burner slowly into the rails until it contacts the rear combustion chamber. The fit should be snug, but not excessively tight.

PST56765 sealant or equivalent on the threads.

(Full-Vat Illustrated)

Because it is not feasible to attempt to include in this manual every conceivable problem or trouble condition that might be encountered, this section is intended to provide technicians with a general knowledge of the broad problem categories associated with this equipment, and the probable causes of each. With this knowledge, the technician should be able to isolate and correct any problem encountered. Problems you are likely to encounter can be grouped into six categories:
Ignition failure occurs when the ignition module fails to sense a flame within the 4-second time delay period and locks out. When this happens, the module sends 24 VAC through the interface board alarm circuit to the computer. M2000 computers display “IGNITION FAILURE.” The three primary reasons for ignition failure, listed in order of probability, are problems related to:
3. Gas valve. PROBLEMS RELATED TO THE GAS AND/OR ELECTRICAL POWER SUPPLIES The main indicators of this are that an entire battery of fryers fails to light and/or there are no indicator lights illuminated on the fryer experiencing ignition failure. Verify that the quick disconnect fitting is properly connected, the fryer is plugged in with connector twisted and locked, the main gas supply valve is open, and the circuit breaker for the fryer electrical supply is not tripped. PROBLEMS RELATED TO THE ELECTRONIC CIRCUITS If gas and electrical power are being supplied to the fryer, the next most likely cause of ignition failure is a problem in the 24 VAC circuit. Verify that the drain valve is fully closed. The valve is attached to a microswitch that must be closed for power to reach the gas valve (often, although the

valve handle appears to be in the closed position, the microswitch is still open). If the valve is fully closed, refer to Section 1.8.1, TROUBLESHOOTING THE 24 VAC CIRCUIT. Some typical causes of ignition failure in this category include a defective sensing wire in the ignitor assembly, a defective module, a defective ignition wire, and a defective ignitor. Occasionally you may encounter an ignition failure situation in which all components appear to be serviceable and the microamp reading is within specification, but the unit nevertheless goes into ignition failure during operation. The probable cause in this case is an intermittent failure of an ignition module. When the unit is opened up for troubleshooting, the module cools down enough to operate correctly; however, when the unit is again closed up and placed back into service the module heats up and fails. PROBLEMS RELATED TO THE GAS VALVE If the problem is not in the 24 VAC circuit, it is most likely in the gas valve, itself. Before replacing the gas valve, refer to Section 1.8.2 TROUBLESHOOTING THE GAS VALVE. 1.7.2 Improper Burner Function
With problems in this category, the burner ignites but exhibits abnormal characteristics such as “popping,” dark spots on the burner ceramics, fluctuating flame intensity, and flames shooting out of the flue. “Popping” indicates delayed ignition. In this condition, the main gas valve is opening but the burner is not immediately lighting. When ignition does take place, the excess gas “explodes” into flame, rather than smoothly igniting. The primary causes of popping are:

kitchen area, this indicates that more air is being exhausted than is being replenished and the burners may be starved for air. If the fryer’s gas and air supplies are okay, the problem is most likely with one of the electrical components. Examine the ignition module and controller for signs of melting, distortion, and/or discoloration due to excessive heat build-up in the fryer (this condition usually indicates improper flue performance). A melted or distorted ignition module is automatically suspect and should be replaced; however, unless the condition causing excessive heat is corrected, the problem is likely to recur. Verify that the ignition wire is tightly connected at both ends and free of obvious signs of damage. Again, if damage is due to excessive heat in the fryer, that problem must also be corrected. Check for proper operation by disconnecting the wire from the ignitor (spark plug), inserting the tip of a screw driver into the terminal. With the insulated handle of the screwdriver, hold the shaft near the frame of the fryer as the power switch is placed in the ON position. A strong, blue spark should be generated for at least 4 seconds.
The sparking charge is approximately 25,000 volts. Examine the ignitor (spark plug) for any signs of cracking. A cracked ignitor must be replaced. If all other causes have been ruled out, examine the burner tiles for any signs of cracking. If cracking is found, the burner must be replaced. Fluctuating flame intensity is normally caused by either improper or fluctuating incoming gas pressure, but may also be the result of variations in the kitchen atmosphere. Verify incoming gas pressure in the same way as for “popping,” discussed in the preceding paragraphs. Variations in the kitchen atmosphere are usually caused by air conditioning and/or ventilation units starting and stopping during the day. As they start and stop, the pressure in the kitchen may change from positive or neutral to negative, or vice versa. They may also cause changes in airflow patterns that may affect flame intensity. Dark spots on the burner tiles are the result of an improper air/gas mixture. Adjust the combustion air blower to reduce the amount of air in the mixture to correct this problem Flames shooting out of the flue are usually an indication of negative pressure in the kitchen. Air is being sucked out of the burner enclosure and the flames are literally following the air. If negative pressure is not the cause, check for high burner manifold gas pressure in accordance with the procedures in Section 1.4. An excessively noisy burner, especially with flames visible above the flue opening, may indicate that the gas pressure is too high, or it may simply be that the gas valve vent tube is blocked. If the incoming gas pressure is correct and the vent tube is unobstructed, the gas valve regulator is probably defective. Occasionally a burner may apparently be operating correctly, but nevertheless the fryer has a slow recovery rate (the length of time required for the fryer to increase the oil temperature from 270ºF to

320ºF (132ºC to 160ºC)). The primary causes of this include an over-filled frypot, a dirty or out-of-adjustment combustion air blower, low burner manifold pressure, and/or damaged burner tiles. Adding oil to the frypot during the recovery process will also cause a slow recovery rate. If these causes are ruled out, the probable cause is a misadjusted gas valve regulator. Refer to Section 1.4, Checking the Burner Manifold Gas Pressure, for the gas valve adjustment procedure. 1.7.3 Improper Temperature Control
Temperature control, including the melt cycle, is a function of several interrelated components, each of which must operate correctly. The principle component is the temperature probe. Other components include the interface board, the controller itself, and the ignition module. Improper temperature control problems can be categorized into melt cycle problems and failure to control at setpoint problems. MELT CYCLE PROBLEMS
In fryers equipped with M2000 computers, initiation of the melt cycle is automatic. Problems may originate from the controller itself, the temperature probe, or a malfunctioning heat relay on the interface board. FAILURE TO CONTROL AT SETPOINT Problems in this category may be caused by the temperature probe, the interface board, or the controller. 1.7.4 Computer Malfunctions
RECOVERY TIME Recovery time – is a method of measuring a fryer’s performance. Put simply, it is the time required for the fryer to increase the oil temperature from 270ºF to 320ºF (132ºC to 160ºC). This range is used as a standard since ambient kitchen temperatures can affect the test if lower ranges are used. The M2000 computer performs the recovery test each time the fryer warms up. An operator can view the results of the test any time the fryer is above the 325ºF (163ºC) point by pressing the button and entering the code 1652. The test results will be displayed in the computer’s LED panel in minutes and seconds. The maximum acceptable recovery time for BIPH52/55-MPH52/55 Series gas fryers is two minutes and twenty-five seconds.

COMMON COMPUTER COMPLAINTS Most problems concerning computers have to do with programming them. There are two common complaints: 1. Fryer constantly displays “HI.”
Cause: Setpoint is incorrect or missing.
Corrective Action: Check setpoint and refer to the M2000 computer manual for instructions to adjust the setpoint. 2. Temperature is displayed in Celsius.
Cause: Computer is programmed to display in Celsius.
Corrective Action: Turn the computer off then press 1658.
The majority of filtration problems arise from operator error. One of the most common errors is placing the filter pad on the bottom of the filter pan rather than over the filter screen. Whenever the complaint is “the pump is running, but no oil is being filtered,” check the installation of the filter pad, including that the correct size is being used. While you are checking the filter pad, verify that the O-rings on the filter pan suction tube are present and in good condition. Missing or worn O-rings will allow the pump to suck air and decrease its efficiency. If the pump motor overheats, its thermal overload will trip and the motor will not start until it is reset. If the pump motor does not start, press the red reset switch located on the front of the motor. If the pump then starts, something caused the motor to overheat. It may be just that several frypots in a large battery of fryers were being filtered one after the other and the pump became hot. Letting the pump cool down for at least a half-hour is all that is required in this case. More often, the pump overheated for one of the following reasons:

A pump seized by debris or hard shortening can usually be freed by manually moving the gears with a screwdriver or other instrument as illustrated on the following page. Make sure power to the pump motor is off before trying this. 1. Disconnect power to the filter system. 2. Remove the input plumbing from the pump. 3. Use a screwdriver to manually turn the gears.

Filter pads that are installed incorrectly will also allow food particles and sediment to pass through and clog the suction tube recess on the bottom of the filter pan or the suction tube, itself. Particles large enough to block the suction tube recess or the suction tube may indicate that the crumb tray is not being used. The electronics of the FootPrint PRO system, illustrated in the schematic below, are simple and straightforward. Microswitches, which are attached to handles for each vat and wired in parallel, provide the 24 VAC required to activate the pump relay coil when the handles are moved to the ON position. The activated pump relay coil pulls in the pump motor switch, supplying power to the pump motor.

Verifying Solenoid Operation Proper operation of the 24 VAC manifold and pump solenoids can be verified by removing the pump motor lead from terminal 4 of the pump motor relay in the filter wiring box and then activating the oil return lever. Proper solenoid operation will be evidenced by an audible “click” or vibration of both the pump solenoid and the manifold solenoid. 1.7.6 Leakage Leakage of the frypot will usually be due to improperly sealed high-limit thermostats, temperature probes, and drain fittings. When installed or replaced, each of these components must be sealed with
Sediment Particle

Loctite® PST56765 sealant or equivalent to prevent leakage. In very rare cases, a leak may develop along one of the welded edges of the frypot. When this occurs, the frypot must be replaced. If the sides or ends of the frypot are coated with oil, the most likely cause is spillage over the top of the frypot rather than leakage. The clamps on the rubber boots that hold the drain tube sections together may loosen over time as the tubes expand and contract with heating and cooling during use. Also, the boot itself may be damaged. If the section of drain tube connected to the drain valve is removed for any reason, ensure that its rubber and clamps are in good condition and properly fitted around the drain tube when it is reinstalled. Also, check to ensure that the drain tube runs downward from the drain along its whole length and has no low points where oil may accumulate. 1.8 Troubleshooting Guides The troubleshooting guides on the following pages are intended to assist service technicians in quickly isolating the probable causes of equipment malfunctions by following a logical, systematic process. An additional set of operator troubleshooting guides is contained in Chapter 6 of the BIPH52/55-MPH52/55 Series Installation and Operation Manual (P/N 819-6087). It is suggested that service technicians thoroughly familiarize themselves with both sets. 1.8.1 Troubleshooting the 24 VAC Circuit Prior to checking for problems associated with the 24 VAC circuit, ensure that the unit is connected to a power supply, the drain valve is fully closed, and the controller is on and is calling for heat (green dot appears under heat indicator and display toggles between LOW and TEMP). NOTE: All voltage measurements must be made within 4 seconds of the unit calling for heat. If unit does not fire within 4 seconds, ignition modules will lock out and controller must be turned off, then on to reset. The following processes will assist you in troubleshooting the 24 VAC circuit and ruling it out as a probable cause: • 24 VAC is not present on the interface board J3 pin 9 (LED 5 (GV)) and, on dual units, on J1 pin 9 (LED 1 (GV)).
a. If 24 VAC is not present, the probable cause is a failed interface board, blown fuse or a
defective heat relay. b. If 24 VAC is present, check for 24 VAC on V1S (or V1D and V2D, if dual unit).

i. If 24 VAC is not present, check the fuses. If they are good, the probable causes are
failed ignition module(s) or a failed interface board. Replace the questionable ignition module with one known to be good to isolate the cause. ii. If 24 VAC is present, the probable cause is a failed interface board. • 24 VAC is present on interface board J3 pin 9 (LED 5 (GV)) and, on dual units, on J1 pin 9 (LED 1 (GV)). 1. If 24 VAC is not present across the gas valve main coil (MV terminals), probable causes are an open high-limit thermostat or a failed wire between the interface board and gas valve. Be sure to check both valves on dual units. It may also be caused by a failed drain safety switch.
Check continuity of high-limit thermostat and drain safety switch. If both are zero, problem is in wiring. 2. If 24 VAC is present across the gas valve main coil (MV terminals), the 24 VAC circuit is okay and the problem may be with the gas valve. Be sure to check both valves on dual units.

24 VOLT CIRCUIT With Interface Board 106-0386 and One 807-3366 (FV) Ignition Module
J3 PIN 8
FUSE
Heat Relay (K3 Replaceable)
LED 4 (PWR)
MODULE
V1S
High Voltage to Left Ignitor
MODULE
High Voltage to Right Ignitor
V1D
LED 5 (GV)
LED 5 (GV)
J3 PIN 9
J3 PIN 9
HIGH LIMIT SWITCH
DRAIN SAFETY SWITCH
This switch used only with
built-in filtration systems.

24 VOLT CIRCUIT With Interface Board 106-0386 and Two 807-3365 (DV) Ignition Modules
J3 PIN 8
FUSE
LED 3 (24V)
Heat Relay (K3 Replaceable) Heat Relay (K2 Replaceable)
LED 4 (PWR)
PWR
PWR
to Ignitor High Voltage
IGNITION
Flame Sensor Flame Sensor
MODULE
V2D
V1D
LED 1 (GV)
LED 5 (GV)
J1 PIN 9 J3 PIN 9
HIGH LIMIT SWITCH
HIGH LIMIT SWITCH
DRAIN SAFETY SWITCH
DRAIN SAFETY SWITCH
This switch used only with
built-in filtration systems.
GAS VALVE
LEFT VAT
RIGHT VAT
High Voltage · to Ignitor

a. If outgoing gas pressure is not correct, the probable cause is an improperly adjusted or
failed gas valve. Adjust the valve by following the procedure “Check Burner Manifold Pressure” in Section 1.4 of this manual.
If the valve cannot be adjusted, replace it.
b. If outgoing gas pressure is correct, the gas valve is okay.
CAUTION Disconnect the M2000 computer before testing temperature probe resistances to avoid invalid readings Prior to checking for problems associated with the temperature probe, inspect the probe body for damage while it is still in the frypot. Remove and replace the probe if it is bent, dented, or cracked. Also, inspect leads for fraying, burning, breaks, and/or kinks. If found, replace the probe. The following processes will assist you in troubleshooting the gas valve and ruling it out as a probable cause: Before testing the probe, determine the temperature the cooking oil using another thermometer or pyrometer placed at the tip of the questionable probe. • If resistance through J3 pins 2 and 6 (J1 pins 2 and 6 for left side of dual unit) is not approximately equal to that given in the Probe Resistance Chart for the corresponding temperature, the probe has failed and must be replaced.

Probe Resistance Chart For use with PRO Series fryers manufactured with Minco Thermistor probes only. F OHMS C F OHMS C F OHMS C F OHMS C F OHMS C 60 1059 16 130 1204 54 200 1350 93 270 1493 132 340 1634 171 65 1070 18 135 1216 57 205 1361 96 275 1503 135 345 1644 174 70 1080 21 140 1226 60 210 1371 99 280 1514 138 350 1654 177 75 1091 24 145 1237 63 215 1381 102 285 1524 141 355 1664 179 80 1101 27 150 1247 66 220 1391 104 290 1534 143 360 1674 182 85 1112 29 155 1258 68 225 1402 107 295 1544 146 365 1684 185 90 1122 32 160 1268 71 230 1412 110 300 1554 149 370 1694 188 95 1133 35 165 1278 74 235 1422 113 305 1564 152 375 1704 191 100 1143 38 170 1289 77 240 1432 116 310 1574 154 380 1714 193 105 1154 41 175 1299 79 245 1442 118 315 1584 157 385 1724 196 110 1164 43 180 1309 82 250 1453 121 320 1594 160 390 1734 199 115 1174 46 185 1320 85 255 1463 124 325 1604 163 395 1744 202 120 1185 49 190 1330 88 260 1473 127 330 1614 166 400 1754 204 125 1195 52 195 1340 91 265 1483 129 335 1624 168 405 1764 207


252 and 452's ONLY, On 352 & 552's Heat strip is attached to pins 7 & 9 of Line

The Heat Strip is not present here on 352/355’s and 552/555’s.
BOX


24V PWR V2S AS AD PWR V2D GND GV
OIL RETURN HEATER FRONT
DETAIL A-A
TO C2 PIN1 TO C2 PIN12
T1 T2
LINE VOLTAGE (L1)
TO C2 PIN3
LINE VOLTAGE(COM)
TO J3 PIN12
WHITE
GV
ALARM(GND)
GND
VALVE(GND)
PWR
V1D
24VAC FUSE
24VAC(GND)
BLOWER
ALR
V1S
INSET HONG KONG
PWR
UNITS ONLY
8051315C/ 8051526B Refer to "PRINCIPAL WIRING CONNECTIONS" on Page 1-37 for detail of connection points J1, J2, J3, C2, C3, and C5.

1.11.2.1 MPH152/155 Transformer / Filter Box

8051523D
NEUTRAL
WHT
RELAY 120 VAC
ORG
GREEN TO
HOOD
BODY
BLK RED
STANDARD 5-WIRE 120/208V NEMA L-21-20P
120/208V 5 WIRE POWER SUPPLY.
RELAY
GREEN
BLACK
WHITE
RED
ORANGE

8051340C

WHT
RELAY 120 VAC
ORG
GREEN TO
BODY
HOOD
BLK RED
DTANDARD 120/208V 5 WIRE POWER SUPPLY.
HOOD
RELAY
GREEN
BLACK
WHITE
RED
ORANGE
Pump Heater · Strip Wires


1.12.1 BIPH52/55 Series Full Vat



3 1 5 9 8 4 6 2 J1


J3 6 2 12 9 11 8 5 4 3 1

CHAPTER 2: PARTS LIST
10 11 12 13
17 18 19 5
ITEM PART # COMPONENT 1 803-0271 Basket, Twin 2 803-0099 Basket, Full (cannot be used with basket lifts) 3 803-0133 Basket Support Rack, Dual Vat 4 803-0132 Basket Support Rack, Full Vat * 803-0136 Basket Support Screen, Full Vat (screen w/handle used in place of Item 4) 5 Coupling, Gas Line Female Quick Disconnect 810-0070 ¾-inch 810-0073 1-inch 6 803-0197 Cleanout Rod, 27-inch (Fryer's Friend) 7 803-0209 Brush, Frypot 8 806-3407 Cover, Frypot, Dual Vat 9 806-3068 Cover, Frypot, Full Vat * 826-0993SP Handle Kit, Frypot Cover (includes handle and screws) 10 910-7443 Connecting Strip, Frypot 11 810-0478 Gas Line, 1-Inch Dormont Flexible 806-1698SP 36-Inch (for gas line only (w/o Items 12 and 13), use 810-0088) 806-1699 48-Inch (for gas line only (w/o Items 12 and 13), use 810-0085) 12 810-0074 Quick-Disconnect Fitting, 1-Inch Male 13 810-0073 Quick-Disconnect Fitting, 1-Inch Female 14 810-2793 Hanger, Basket 15 809-0171 Thumbscrew, ¼-20 X 1⅜-inch Basket Hanger * 809-0921 Spacer, Basket Hanger 16 826-0900 Kit, Chain Restraint 17 826-1045 Bushing, Flexible Gas Line (813-0032)

ITEM PART # COMPONENT 18 812-1378 Drain Extension, Non-Filter Full Vat Fryer 19 812-1374 Drain Extension, Non-Filter Dual Vat Fryer * 803-0219 Pad, McDonald’s FPIII Universal Filter * 803-0170 Filter Pack, Paper – 100 Sheets * 803-0002 Powder, Filter – 80 Packages * 826-1157 Kit, Fuse and Fuse Puller (2 Fuses) * Not illustrated.

2.2.1 Backs, Doors, Flue Caps, Sides, Top Caps, Standoffs and Cap-N-Splash Assemblies


ITEM PART # COMPONENT 1 Back, Single Upper 210-6581 Stainless Steel 200-6581 Cold Rolled Steel 2 Back, Single Lower 210-6580 Stainless Steel 200-6580 Cold Rolled Steel 3 Back, Double Upper (for 2-, 4-, and 5-station fryers – does not include Items 7-9) 210-6542 Stainless Steel 200-6540 Cold Rolled Steel 4 Back, Double Lower (for 2-, 4-, and 5-station fryers – does not include Items 7-9) 210-6541 Stainless Steel 200-6539 Cold Rolled Steel 5 Back, Triple Upper (for 3- and 5-station fryers – does not include Items 7-9) 210-6545 Stainless Steel 200-6547 Cold Rolled Steel 6 Back, Triple Lower (for 3- and 5-station fryers – does not include Items 7-9) 210-6544 Stainless Steel 200-6546 Cold Rolled Steel 7 200-6419 Clip, Flue Support 8 200-5865 Support, Flue Cap 9 826-1374 Screw, #10 X ½-inch Hex Washer Head (Pkg. of 25) 10 106-3966 Door, Left or Right (Left shown – move handle to bottom for Right) 11 809-0266 Screw, #10 X ½-inch Phillips Truss Head 12 210-6816 Handle, Door 13 823-4729 Hinge, Left Door Upper 14 823-4730 Hinge, Right Door Upper 15 Flue Cap-Stainless Steel (Does not include Item 27) 210-5549 Single Fryer 106-3579 2-Station Fryer 106-3537 3-Station Fryer 106-3535 4-Station Fryer 106-3536 5-Station Fryer 16 Flue Cap - Aluminized Steel for use with Cap-N-Splash 210-5525 Single Fryer 106-3539 2-Station Fryer 106-3540 3-Station Fryer 106-3542 4-Station Fryer 106-3543 5-Station Fryer 17 Side, Left Standard Cabinet 211-6510SP Stainless Steel 201-6633 Enameled Steel 18 Side, Right Standard Cabinet 212-6510SP Stainless Steel 202-6633 Enameled Steel 19 Top Cap (Cap for 5-staion fryer shown) 824-1310 Single Fryer (use 824-1689 for fryers mfd. After 3.15.06) 824-1357 2-Station Fryer (use 824-1690 for fryers mfd. After 3.15.06) 823-4702 3-Station Fryer (use 823-5733 for fryers mfd. After 3.15.06) 823-4704 4-Station Fryer (use 824-5734 for fryers mfd. After 3.15.06) 823-4706 5-Station Fryer (use 824-5735 for fryers mfd. After 3.15.06)

ITEM PART # COMPONENT 20 Standoffs 200-6582 Single Fryer 200-6553 2-Station Fryer 200-6554 3-Station Fryer 200-6555 4-Station Fryer 200-6556 5-Station Fryer 21 Cap-N-Splash Assemblies 823-3066 Single Fryer 823-3067 2-Station Fryer 823-3068 3-Station Fryer 823-3070 4-Station Fryer 823-3069 5-Station Fryer 22 826-1351 Nut Retainer, ¼-20 (Pkg. of 10 – for basket hanger thumbscrew) for Std. Fluecap 23 809-0171 Thumbscrew, ¼-20 x 1⅜-inch (for use on Standard Fluecap) 24 809-0402 Thumbscrew, ¼-20 x ½-inch (for use on Cap-N-Splash Assembly) 25 809-0535 T-Nut, ¼-20 x 7/16-inch (for use on Cap-N-Splash Assembly)


The 5-station cabinet illustrated is typical of all BIPH52/55 Series Gas filter cabinets. All base and framing components used in BIPH52/55 Gas filter cabinets are identified, but not all components are used in every configuration.
All cabinet screws, unless otherwise indicated, are #10 x 1/2-inch Hex Washer Head P/N 826-1374, sold in packages of 25. 34

ITEM PART # COMPONENT 1 106-4303 Frame, Control Panel, Two Station, (use 106-5221SP mfd. After 3.15.06) 106-4304 Three-Station, Standard (use 106-5018SP mfd. After 3.15.06) 106-4305 Four-Station, Standard (use 106-5019 mfd. After 3.15.06) 106-4306 Five-Station, Standard (use 106-5020 mfd. After 3.15.06) 2 210-5819 Bezel, Two-Controller 3 210-6698 Bezel, Three-Controller 4 210-5046 Bezel, One-Controller 5 210-5623 Bezel, Blank 6 900-7730 Brace, Cabinet Top Two-Station 900-9430 Three-Station 900-9318 Four-Station 200-5474 Five-Station 7 200-5478 Divider, Cabinet 8 200-9217 Post, Cabinet Front 9 200-6031 Post, Filter Door 10 200-2235 Bracket, Component Box Support 11 200-6550 Post, Cabinet Rear 12 200-1953 Brace, Front Cabinet 13 200-6507 Support, Cross Cabinet 14 810-1105 Magnet, Door 15 Manifold, Rear (for units w/ filtration also see page 2-17 for additional parts) 810-2890 Two-Station 810-2891 Three-Station 810-2892 Four-Station 810-2893 Five-Station 16 200-2213 Bracket, Rear Bridge Support 17 200-9818 Bridge, Filter Pump 18 200-6326 Gusset, Left Rear Corner 19 200-7031 Gusset, Right Rear Corner 20 201-9467 Support, Left Filter Rail 21 202-9467 Support, Right Filter Rail 22 823-4651 Slide, Filter Pan Lid Left 23 823-4652 Slide, Filter Pan Lid Right 24 200-2102 Brace, Side Channel 25 823-4653 Channel, Side Base 26 Channel, Front Base (not used in two-station fryers) 200-6609 Three-Station 200-6610 Four-Station 200-5473 Five-Station 27 823-4510 Channel, Rear Base Two-Station 823-4630 Three-Station 823-4629 Four-Station 823-4628 Five-Station 28 823-4732 Hinge, Lower Left 29 823-4733 Hinge, Lower Right (attach to Hinge Bracket 200-5478 in 4- & 5-station fryers) 30 810-0944 Caster w/Brake, 8½ to 10-inch Adjustable (3-inch wheel) 31 810-0327 Caster w/o Brake, 8½ to 10-inch Adjustable (4-inch wheel) 32 809-0953 Bolt, ¼-20 x ¾-inch Hex Head 33 809-0191 Washer, ¼-inch Lock 34 809-0417 Nut, ¼-20 Flange 35 201-6720 Mount, Rear Flush Rod Offset, Left 36 200-6697 Mount, Rear Flush Rod Holder, Center 37 202-6720 Mount, Rear Flush Rod Offset, Right * 200-6036 Base Shield


The 5-station cabinet illustrated is typical of all MPH52/55 Series Gas non-filter cabinets. All base and framing components used in MPH52/55 Series Gas non-filter cabinets are identified, but not all components are used in every configuration.
All cabinet screws, unless otherwise indicated, are #10 x 1/2- inch Hex Washer Head P/N 826-1374, sold in packages of 25.

ITEM PART # COMPONENT 1 Frame, Control Panel 106-4302 Single-Station, Standard (use 106-5016 mfd. After 3.15.06) 106-4303 Two-Station, Standard (use 106-5221SP mfd. After 3.15.06) 106-4304 Three-Station, Standard (use 106-55018SP mfd. After 3.15.06) 106-4305 Four-Station, Standard (use 106-5019 mfd. After 3.15.06) 106-4306 Five-Station, Standard (use 106-5020 mfd. After 3.15.06) 2 210-5819 Bezel, Two-Controller 3 210-6698 Bezel, Three-Controller 4 210-5046 Bezel, One-Controller 5 210-5623 Bezel, Blank 6 Brace, Cabinet Top 200-5498 Single Fryer 900-7730 Two-Station 900-9430 Three-Station 900-9318 Four-Station 200-5474 Five-Station 7 200-5478 Divider, Cabinet 8 200-6614 Post, Cabinet Front 9 200-2235 Bracket, Component Box Support 10 200-6550 Post, Cabinet Rear 11 200-1953 Brace, Front Cabinet 12 200-6507 Support, Cross Cabinet 13 810-1105 Magnet, Door 14 Manifold, Rear (not present in single fryers) 823-3223 Two-Station 823-4691 Three-Station 823-4693 Four-Station 823-4694 Five-Station 15 823-4653 Channel, Side Base 16 Channel, Front Base 200-6616 Single Fryer (also used as rear base channel in single-station fryers) 200-6623 Two-Station (also used as rear base channel in single-station fryers) 200-6624 Three-Station (also used as rear base channel in single-station fryers) 200-6625 Four-Station 200-6627 Five-Station 17 Channel, Rear Base 200-6626 Four-Station 200-6628 Five-Station 18 823-4732 Hinge, Lower Left 19 823-4733 Hinge, Lower Right (attach to Bracket 200-5478 in 3-, 4-, & 5-station fryers) 20 810-0944 Caster w/Brake, 8½ to 10-inch Adjustable (3-inch wheel) 21 810-0327 Caster w/o Brake, 8½ to 10-inch Adjustable (4-inch wheel) 22 809-0953 Bolt, ¼-20 x ¾-inch Hex Head 23 809-0191 Washer, ¼-inch Lock 24 809-0417 Nut, ¼-20 Flange


1 2 3 4 5 6 7 8 9 0
ABC DEF GHI JKL MNO PQR STU VWX YZ- * -
ITEM PART # COMPONENT 1 Computer, McDonald’s M2000 Gas Fryer 106-1269 Full Vat (Domestic U.S.) Can also be programmed for Dual Vat. 106-0672 Full Vat (CE) Can also be programmed for Dual Vat. 106-5950 Full Vat (CE) Can also be programmed for Dual Vat (Australia Only) * 807-3520 M2000 Speaker * Not illustrated.

2.4.1 Filtration System Components


ITEM PART # COMPONENT 1 106-2617SP Pan Assembly, FootPrint Pro Filter (incl. O-rings, rollers, nuts & crumb tray) 826-1980 Pan Assembly – No Screen 823-3930SP Pan Assembly, Filter 813-0568 Plug, ⅛-inch NPT Socket Head 826-1392 O-Ring (two required) (Pkg. of 5) 810-2198 Roller, Filter Pan 826-1372 Nut, ¼-20 Hex Flange (Pkg. of 10) 826-1979 Kit- Contains four each of roller 810-2198 and ¼-20 Flange Nut 809-0059 1a 810-2012 Rail Set, Filter Pan Roller (includes one left and one right) 2 200-2240 Screen, Sana Grid 3 810-2183 Ring, Filter Pad Hold-Down Ring (11.20-inch X 19.10-inch) 810-2091 Ring, Filter Paper Hold-Down Ring (13.47-inch X 21.41-inch) 4 823-5146 Tray, Filter Pan Crumb 5 823-5249 Lid, Filter Pan 6 823-4678 Tube, 3-inch Center Drain (Open Both Ends) 823-4708 Closed One End 7 Tube, 3-inch Round Drain (823-4625 illustrated) 823-4638 Dual Vat, Long (one end closed) 823-4640 Dual Vat, Long (open both ends) 823-4624 Dual Vat, Short (one end closed) 823-4642 Dual Vat, Short (open both ends) 823-4639 Full Vat, Long (one end closed) 823-4641 Full Vat, Long (open both ends) 823-4625 Full Vat, Short (one end closed) 823-4643 Full Vat, Short (open both ends) 200-6473 Spreader, Long (open both ends, no drain valve connection) 200-6474 Spreader, Short (open both ends, no drain valve connection) 8 809-0247 Nut, 8-32 Hex Keps 9 816-0625 Sleeve, Round Drain Connector 10 809-0969 Clamp, Round Drain Sleeve 11 810-2493 Elbow, ¼-inch NPT X 90° Tube Compression 12 811-1071 Tube, ¼-inch OD Teflon Manifold Vent 13 823-3879 Suction Tube, FootPrint Pro Female 14 810-1055 Flexline, ⅝-inch OD X 11.50-inch 15 810-1668 Adapter, ⅝-inch OD X ½-inch Male 16 813-0530 Tee, ½-inch X ½-inch X ¼-inch Reducing 17 813-0838 Nipple, ¼-inch NPT Close 18 807-2484 Solenoid Valve w/Female Pins 19 810-2773 Adapter, ½-inch OD Flare x ¼-inch NPT 20 810-2787 Flexline, ½-inch OD X 5.00-inch 21 813-0165 Elbow, ½-inch NPT X 90° Street 22 810-1680 Flexline, ⅝-inch OD x 11.50-inch 23 813-0265 Nipple, ½-inch NPT X 2.50-inch 24 813-0342 Elbow, ½-inch NPT X 45° Street 25 813-0298 Nipple, ½-inch NPT X 2.00-inch 26 826-1264 Pump and Gasket Kit (for gasket only, order P/N 816-0093) 27 Motor and Gasket Kit, 50/60 Hz (for gasket only, order P/N 816-0093) 826-1785 100V 826-1712 115V 826-1756 208V 826-1270 220-240V 826-1755 250V



ITEM PART # COMPONENT 1 810-1569 Valve Assembly, 1.25-inch Full-Vat Non-Filter Drain (includes handle) * 810-1427 Lock Pin Handle for 1.25-inch Valve Assembly 2 806-7915SP Valve Assembly, 1-inch Left Dual-Vat Non-Filter Drain (complete assembly) 3 806-7916SP Valve Assembly, 1-inch Right Dual-Vat Non-Filter Drain (complete assembly) 4 809-0589 Nut, ½-13 2-Way Lock (used on non-filter drain valves) 5 810-1427 Handle w/Lock Pin, Full Vat 6 810-1568 Handle w/Lock Pin, Left Drain Valve Dual Vat 7 810-1567 Handle w/Lock Pin, Right Drain Valve Dual Vat 8 106-3760SP Valve Assembly, 1.25-inch Full-Vat w/Filter Drain (complete assembly) 9 106-5607SP Valve Assembly, 1-inch Left Dual-Vat w/Filter Drain (complete assembly) 10 106-5606SP Valve Assembly, 1-inch Right Dual-Vat w/Filter Drain (complete assembly) 11 816-0135 O-Ring, Drain Valve 12 810-1018 Valve, 1.25-inch Drain 13 806-8137 Bracket Assembly, Drain Safety Switch 14 816-0220 Insulation, Drain Safety Switch 15 807-2103 Microswitch, Lever Activated 16 901-2348 Cover, Drain Safety Switch 17 826-1366 Nut, 4-40 Hex Keps (Pkg. of 25) 18 824-1602 Handle, Full-Vat Drain Valve 19 900-2936 Retainer, Full-Vat Drain Valve Nut 20 809-0540 Nut, ½-13 2-Way Lock 21 816-0639 Grip, Drain Valve Handle 22 200-6496 Support, 3-inch Drain Tube 23 810-1114 Valve, 1-inch Dual-Vat w/Filter Drain 24 809-0196 Washer, ⅜-inch Flat 25 810-1165 Washer, ⅜-inch Teflon 26 900-2934 Retainer, Dual-Vat Drain Valve Nut 27 809-0539 Nut, ⅜-16 2-Way Lock 28 824-1637 Handle, Left Dual-Vat Drain Valve 29 824-1636 Handle, Right Dual-Vat Drain Valve (Must order item 16 and item 30 to fit) 30 106-2671 Bracket Assembly, Dual-Vat Drain Safety Switch 31 810-1338 Valve, 1-Inch Dual-Vat Non-Filter Drain 32 Drain Valve Extension 812-1226SP Full-Vat (1.25-inch) 812-1227 Dual-Vat (1-inch)



ITEM PART # COMPONENT 1 Valve Assembly, Microswitch and Ball Valve 106-3452 Valve Rear Flush Assembly, Left Side 106-3453 Valve Rear Flush Assembly, Right Side 2 810-2493 Elbow, 90° x ¼-inch 3 809-0601 Clip, Rod End Clevis 4 Shaft, Rear Flush Valve 211-6701 For use in Left oil return valve assemblies. 212-6701 For use in Right oil return valve assemblies. 5 Handle, Rear Flush Valve 901-2772 For use in Left oil return valve assemblies. 902-2772 For use in Right oil return valve assemblies. 6 813-0165 Elbow, 90° x ½-inch Street 7 813-0087 Nipple, 1½-inch BM NPT 8 810-2201 Valve, ½-inch Ball * 900-2935 Oil Return Valve Nut Retainer 9 810-1668 Adapter, Male ⅝-inch Flexline to ½-inch NPT Male 9a 810-2786 Adaptor, ½-inch Flare x ½ -inch NPT 10 807-2484 Valve, ¼-inch NPT Solenoid Vent 11 Manifold, BIPH52 Rear Flush Oil Return 810-2890 Two-Station Fryer 810-2891 Three-Station Fryer 810-2892 Four-Station Fryer 810-2893 Five-Station Fryer 12 813-0156 Cap, ½-inch Pipe 13 816-0220 Insulation, Rear Flush Switch 14 807-4101 Microswitch, Lever Activated 15 826-1366 Nut, 4-40 Keps Hex (Pkg. of 25) 16 826-1359 Screw, 4-40 x ¾-inch Slotted Round Head (Pkg. of 25) 17 809-0250 Nut, 6-32 Keps Hex 18 200-8745 Cover, Microswitch Rear Flush 19 807-0125 Bushing, .50 ID Heyco SB-750-8 Nylon 20 813-0700 Nipple, ¼ NPT x 3-inch 21 816-0643 Grip, Oil Return Handle 22 810-1067 Flexline, ⅝-inch OD x 8.50-inch Oil Return 23 810-2787 Flexline, ½” x 5.00-inch Pump to Oil Return Manifold 24 810-1680 Flexline, ⅝-inch OD x 6.50-inch Oil Return Manifold to Pump 25 811-1071 Tube, ¼-inch OD Teflon Manifold Vent

2.5.1 Component Boxes

CE and Non-CE Export Units Except Austraila and Hong Kong

ITEM PART # COMPONENT 1 810-1164 Block, One-Piece Screwless Terminal 2 200-5996 Box, One-Piece Component 3 807-1926 Bushing, .875-inch Split 4 807-3483 Cable, 21-inch Ignition H50/H52 –For 807-3366/3365 Modules * 826-2024 Cable, Ignition - 1 wire / 1 rajah * 826-1721 Cable, Ignition – 2 wire / 2 rajah 5 807-3484 Connector, Rajah 6 106-0531SP Fuse Assembly, Inline 7 816-0217 Insulation, Terminal Block Paper 8 807-2971 Ignition Module, Australian 9 807-1006 Ignition Module, CE and Non-CE export (except Australia, Canada, HK, Mexico) 10 807-3366† Ignition Module, Dual-Spark Full-Vat (U.S., Canadian, HK, and Mexican units) 807-3365† Ignition Module, Single-Spark Ignition Module Dual-vat (U.S., Canadian, HK, and Mexican units) 11 826-2264 Interface Board Kit; U.S., CE and non-CE (except Hong Kong) 106-6706 Interface Board SMT, U.S., CE and non-CE (except Hong Kong) 807-4330 Sound Device/Speaker Adapter Harness SMT 807-4343 Wire Harness, SMT Interface Board to Ignition Module 12 106-0387 Interface Board, Australian 13 806-4973 Interface Board, Hong Kong 14 807-1359 Mount, Ty-Wrap 15 826-1366 Nut, 4-40 Keps Hex (Pkg. of 25) 16 809-0250 Nut, 6-32 Keps Hex 17 807-0833 Relay, DPDT 5A 12VDC Latch (See NOTE 1.) 18 806-2071 Cable, 15-pin Computer to Interface Board 19 809-0441 Screw, #8 X 1½-inch Hex Washer Head 20 826-1359 Screw, 4-40 X ¾-inch Slotted Round Head (Pkg. of 25) 21 809-0098 Screw, 6-32 X 1¼-inch Slotted Round Head 22 826-1346 Spacer, Ignition Module (Pkg. of 10) 23 810-2763 Spacer, Interface Board 24 810-2243 Spring, Relay Retaining 25 826-1337 Tab, ¼-inch Terminal (Pkg. of 5) 26 807-1948 Ty-Wrap 27 806-6085SP Wire Assembly, Ignition Module 28 807-3843 Fuse 3A 250V Domestic 807-3293 Fuse 5A 125V International Only * 807-1200 Ignition Wire, 27” * 807-1878 Ignition Wire, 19” * 807-3520 Sound Device, High Output * Not illustrated.
† For Dual-vat units, use 807-3365 Single Spark Ignition Module (see NOTE 1). NOTE 1: U.S., Canadian, Hong Kong, and Mexican units use two different modules depending upon the configuration of the frypot. Dual-Vat units use two 807-3365 Single-Spark Ignition Modules. Full-Vat units use one 807-3366 Dual-Spark Ignition Module. Also, in full-vat units, only one latch relay (Item 17) is used, located in the lower right socket.





ITEM PART # COMPONENT Box Assembly, Transformer A 106-1380 100-120V FMPH152/155, FMPH352/355, FMPH452/455 B 106-3818 100-120V BIPH 252/255, BIPH 452/455, FMPH252/255 C 106-4888 100-120V BIPH 352/355 D 106-3819 208-240V BIPH 252/255 and BIPH 452/455 CE/Non-CE Export E 106-3817 250V BIPH 252 and BIPH 452 CE/Non-CE Export F 106-3824 208-240V BIPH 352/355 CE/Non-CE Export G 106-3823 250V BIPH 352/355 CE/Non-CE Export 1 106-3820 Cable Assembly, Transformer Box #1 2 106-3821 Cable Assembly, Transformer Box #2 3 106-1011 Cable Assembly, Transformer Box Line 4 106-1016 Cable Assembly, Transformer Box Filter Pump 5 106-3827 Cable Assembly, Transformer Box #1 (On Box G this PN# becomes 106-4898) 6 106-4990 Cable Assembly, Transformer Box Line 7 106-3825 Cable Assembly, Transformer Box #3 8 106-3826 Cable Assembly, Transformer Box Filter Pump 9 106-3316 Cable Assembly, Transformer Box Line 10 200-1415 Cover, Transformer Box 11 200-6721 Plate, Strain Relief 12 200-2318 Cover, Transformer Box Cable Plate 13 807-0012 Relay, 18 Amp 1/3-HP 24V Coil 14 807-0070 Terminal, Ground Lug 15 807-0155 Connector, 9-Pin Male 16 807-0680 Transformer, 208-240V/24VAC 50/60Hz 20VA 17 807-0800 Transformer, 100-120V/24VAC 50/60Hz 50VA ( On Box C PN# is 807-1238) 18 807-1973 Terminal, Post 19 807-1999 Transformer, 208-240V V/F Dual Voltage 20 807-2176 Transformer, 100-120V V/F Dual Voltage 21 809-0052 Nut, 10-24 Hex 22 826-1362 Nut, 1/4-20 Hex (Pkg. of 10) 23 826-1363 Screw, 8-32 X 1/2-inch Slotted Truss Head (Pkg. of 25) 24 809-0123 Screw, 10-24 X 3/4-inch Slotted Truss Head 25 826-1389 Screw, 1/4-20 X 3/4-inch Hex Head (Pkg. of 10) 26 826-1366 Nut, 4-40 Keps Hex (Pkg. of 25) 27 809-0247 Nut, 8-32 Keps Hex 28 826-1376 Nut, 10-32 Keps Hex (Pkg. of 10) 29 826-1359 Screw, 4-40 X 3/4-inch Slotted Round Head (Pkg. of 25) 30 809-0360 Screw, #8 X 3/8-inch Hex Washer Head 31 809-0656 Screw, 4-40 X 3/8-inch Slotted Round Head 32 810-1164 Block, One-Piece Screwless Terminal 33 816-0217 Insulation, Terminal Block Paper 34 824-1242 Box, Transformer BIPH252, 452 35 824-1301 Box, Transformer BIPH352, 552 36 807-1683 Relay, Hood 12V DC 37 807-0157 Connector, 6-Pin Male 38 816-0219 Paper, CE Triple Terminal Block Insulating 39 810-1163 Block, 3 Places Screwless Terminal 40 106-4894 Cable Assembly, Transformer Box Filter Pump 41 106-4893 Cable Assembly, Transformer Box Line Continued on Next Page

Continued from Previous Page
ITEM PART # COMPONENT * WIR 0623 Wire Assembly, PH52 Hood Relay * WIR0634 Wire Assembly, FPP50 Transformer/Filter Box (used in Item E) * WIR0635 Wire Assembly, FPPH350 Transformer Filter Box (used in Item G) * WIR0439 Wire Assembly, Transformer Box (used in Items B, D, and E) * WIR0447 Wire Assembly, Transformer Box (used in Item A) * WIR0580 Wire Assembly, Transformer Box (used in Item C) * Not illustrated 2.5.3 High-Limit Thermostat and Temperature Probe
ITEM PART # COMPONENT 1 826-1177 Thermostat Assembly, HE FM High-Limit 425°F/218°C 2 806-4206 Temperature Probe 3 210-0681 Probe Guard



ITEM PART # COMPONENT 1 106-1019SP Flue Assembly, Full-Vat 2 200-0936 Back, Left Full-Vat Combustion Chamber 3 200-0937 Back, Right Full-Vat Combustion Chamber 4 200-2227 Retainer, Full-Vat Upper Insulation 5 826-1372 Nut, ¼-20 Flange Hex (Pkg. of 10) 6 826-1371 Screw, #8 X ½-inch Hex Head Drill Point (Pkg. of 25) 7 809-0362 Screw, #8 X 1¼-inch Hex Washer Head Drill Point 8 826-1383 Washer, Steel (Pkg. of 5) 9 809-0500 Screw, #10 X ½-inch Hex Washer Head 410 SS 10 809-0804 Nut, ¼-20 Keps Hex 11 826-1340 Spacer, .25-inch X 1.187-inch (Pkg. of 10) 12 810-0500 Spacer, .25-inch X .9375-inch 13 826-1072 Burner, Universal Replacement 14 812-0355 Insulation, Full-Vat Lower Rear 15 812-0356 Insulation, Burner Sight Glass 16 816-0577 Insulation, Burner 17 812-0404 Insulation, Left or Right Front Seal 18 812-0457 Insulation, Full-Vat Lower Front 19 812-0706 Insulation, Upper Burner Rail 20 812-0993 Insulation, Upper Oil Zone 21 812-1029 Insulation, Combustion Chamber Side 22 814-0048SP Glass, Burner Sight 23 816-0057 Gasket, Plenum 24 816-0560 Insulation, Full-Vat Upper Front 25 816-0561 Insulation, Left or Right Outer Front 26 823-0969 Plenum, Full-Vat 27 823-1777 Side and Rail, Left Full-Vat Combustion Chamber 28 823-3323SP Frypot, Full-Vat 439 SS 29 823-3142 Side and Rail, Right Full-Vat Combustion Chamber 30 823-3304 Front, Full-Vat Right Combustion Chamber 31 823-3305 Front, Full-Vat Left Combustion Chamber 32 823-3315 Retainer, Left Full-Vat Lower Front Insulation 33 823-3316 Retainer, Right Full-Vat Lower Front Insulation 34 824-0863 Retainer, Left Full-Vat Upper Insulation 35 824-0864 Retainer, Right Full-Vat Upper Insulation 36 900-1031 Retainer, Burner Sight Glass 37 900-1049 Retainer, Plenum Gasket 38 900-1221 Retainer, Rear Insulation 39 900-1515 Brace, Upper Oil Zone Insulation 40 900-4452 Retainer, Combustion Chamber Side Insulation 41 930-0818 Bracket, Flue to Frypot 42 900-4253 Strip, Fluecap Retainer * 910-2474 Pot-to-Pot Gap Clip * 106-1049SP Frypot Assembly Full-Vat w/RF HE (NAT) * 106-1050SP Frypot Assembly Full-Vat w/RF HE (PRO) * 106-1053 Frypot Assembly Full-Vat w/RF HE (MFG) * 826-0929 Insulation Kit, Complete Full-Vat * 826-0931 Insulation Kit, Burner Full-Vat * Not Illustrated



ITEM PART # COMPONENT 1 106-1018SP Flue Assembly, Dual-Vat 2 200-0941 Back, Dual-Vat Combustion Chamber 3 200-2229 Retainer, Dual-Vat Upper Insulation 4 826-1372 Nut, ¼-20 Flange Hex (Pkg. of 10) 5 809-0360 Screw, #8 X ⅜-inch Hex Head 6 809-0362 Screw, #8 X 1¼-inch Hex Washer Head Drill Point 7 826-1383 Washer, Steel (Pkg. of 5) 8 809-0500 Screw, #10 X ½-inch Hex Washer Head 410 SS 9 809-0804 Nut, ¼-20 Keps Hex 10 826-1340 Spacer, .25-inch X 1.187-inch (Pkg. of 10) 11 810-0500 Spacer, .25-inch X .9375-inch 12 826-1072 Burner, Universal Replacement 13 812-0354 Insulation, Dual-Vat Lower Rear 14 812-0356 Insulation, Burner Sight Glass 15 816-0577 Insulation, Burner 16 812-0404 Insulation, Left or Right Front Seal 17 812-0458 Insulation, Dual-Vat Lower Front 18 812-0688 Insulation, Flue Collector 19 812-0706 Insulation, Upper Burner Rail 20 812-0993 Insulation, Upper Oil Zone 21 812-1029 Insulation, Combustion Chamber Side 22 814-0048SP Glass, Burner Sight 23 816-0057 Gasket, Plenum 24 816-0558 Insulation, Dual-Vat Lower Front 25 816-0559 Insulation, Dual-Vat Upper Front 26 823-0970 Plenum, Dual-Vat 27 823-2822 Side and Rail, Left Dual-Vat Combustion Chamber 28 823-2823 Side and Rail, Right Dual-Vat Combustion Chamber 29 823-3324SP Frypot, Dual-Vat 439 SS 30 823-3302 Front, Dual-Vat Combustion Chamber 31 823-3303 Retainer, Dual-Vat Lower Front Insulation 32 824-0865 Retainer, Left Dual-Vat Upper Insulation 33 824-0866 Retainer, Right Dual-Vat Upper Insulation 34 900-0914 Retainer, Lower Rear Insulation 35 900-1031 Retainer, Burner Sight Glass 36 900-1049 Retainer, Plenum Gasket 37 900-1515 Brace, Upper Oil Zone Insulation 38 900-4452 Retainer, Combustion Chamber Side Insulation 39 930-0818 Bracket, Flue to Frypot 40 900-4253 Strip, Fluecap Retainer 41 824-0541 Riser, DV Pot Divider W/A * 910-2474 Pot-to-Pot Gap Clip * 106-1079SP Frypot Assembly Dual-Vat w/RF HE (NAT) * 106-1080SP Frypot Assembly Dual-Vat w/RF HE (PRO) * 106-1070 Frypot Assembly Dual-Vat w/RF HE (MFG) * 826-0930 Insulation Kit, Complete Dual-Vat * 826-0932 Insulation Kit, Burner Dual-Vat * Not Illustrated

See Section 2.7 for burners and burner isulation part numbers.
PH252/255 Full Vat Gas Manifold
The example illustrated is typical of BIPH52/55-MPH52/55 Fryer Gas Manifolds. Each manifold is assembled from standard 1/2-, 3/4-, and 1-inch NPT black iron pipe nipples, elbows, tees, plugs, and unions, which may be locally aquired.
See Section 2-9 for details of gas valves and related components.
(Typical)

ITEM PART # COMPONENT 1 Ignitor (includes gasket 816-0059, which may be ordered separately) 826-0981 Natural Gas (G20, G25) 826-0982 Propane (G30, G31) 826-1002 Manufactured Gas 2 826-1371 Screw, #8 X ½-inch Hex Head (Pkg. of 25) 3 Blower Assembly, Combustion Air (includes harness and Items 4, and 5) 106-2996SP 100V 50/60 Hz (Left) 106-2999SP 100V 50/60 Hz (Right) 106-2994SP 115V 50/60 Hz. (Left) 106-2997SP 115V 50/60 Hz (Right) 106-2995SP 208-240V 50/60 Hz (Left) 106-2998SP 208-240V 50/60 Hz (Right) 106-3000SP 230V 50/60 Hz CE (Left) 106-3001SP 230V 50/60 Hz CE (Right) 4 816-0554 Cover, Blower Motor (component of all blowers listed above) 5 809-0938 Screw, 10-32 X ⅝-inch Philips Truss Head (secures Item 4 to Item 3) * 806-8806SP Harness Assembly, Blower Motor (component of all blowers listed above) 6 Orifice, Burner 812-1137 1.95 mm Propane/Butane (G30, G31) (0-4999 Ft, 0-1524 M) (CE) 810-1221 2.00 mm Propane/Butane (0-4999 Ft, 0-1524 M) (Japan only) 810-0386 2.10 mm Propane/Butane (0-4999 Ft, 0-1524 M) 810-0413 2.16 mm Propane/Butane (G30, G31) (5000-6999 Ft, 1525-2133 M) 812-1028 2.20 mm Propane/Butane (G30, G31) (7000-10,999 Ft, 2134-3352 M) 812-1134 3.10 mm Natural Gas (G20, G25) (0-4999 Ft, 0-1524 M) (Japan only) 810-0403 3.40 mm Natural Gas (G20, G25) (0-4999 Ft, 0-1524 M) 810-0437 3.60 mm Natural Gas (G20, G25) (5000-6999 Ft, 1525-2133 M) 812-1144 3.65 mm Natural Gas (G20, G25) (7000-8999 Ft, 2134-2743 M) 812-1145 3.70 mm Natural Gas (G20, G25) (9000-10,999 Ft, 2744-3352 M) 810-0642 5.95 mm Manufactured Gas (0-4999 Ft, 0-1524 M) * 826-1196 Conversion Kit, Natural Gas (G20, G25) to Propane/Butane (G30, G31) CE only * 826-1197 Conversion Kit, Propane/Butane (G30, G31) to Natural Gas (G20, G25) CE only * 807-2263 Switch, Air Pressure (use 807-2262 in units with 100VAC power supply) * Not illustrated.

Non-CE Gas Valve Assembly
CE Gas Valve Assembly
9 10 11 · (Typical) · (Typical)

ITEM PART # COMPONENT 1 Valve, Non-CE Gas 826-1122 Natural Gas (G20, G25) 826-1120 Kit Natural Gas w/ flexlines and hardware 826-1123 Propane Gas (G30, G31) 826-1121 Kit, Propane Gas w/ flexlines and hardware 2 810-1715 Valve, CE Gas (G20, G25, G30, G31) 3 810-1041 Accessory Kit (contains parts to adapt Item 2 to specific fryer configura- tion) 4 810-0691 Tube, ⅛-inch Vent 5 810-0494 Ferrule (Nut), Orifice 6 810-1355 Gas Line, ⅜-inch OD X 15-inch SS Flexible 7 810-1354 Gas Line, ⅜-inch OD X 12-inch SS Flexible 810-1353 Gas Line, ⅜-inch OD X 9-inch SS Flexible (Used on some split pot ap- plications) 8 811-0800 Tube, ⅛-inch OD X 12.5-inch Enrichment (cut and form to fit) 9 813-0301 Tee, ¼-inch Male NPT to ⅜-inch Tube 10 813-0302 Elbow, ¼-inch Male NPT to ⅜-inch Tube 90° (used on DV valve) 11 813-0304 Bushing, ½-inch NPT to ¼-inch NPT Flush Reducing 12 813-0405 Nipple, ⅛-inch NPT X 2-inch 13 813-0378 Fitting, ⅛-inch NPT Cross 14 813-0340 Adapter, ⅛-inch NPT to ⅛-inch Tube 15 813-0154 Plug, ⅛-inch NPT Hex Head Pipe 16 810-1176 Tap, ⅛-inch NPT Pressure 17 813-0377 Tee, ⅛-inch NPT Female 18 813-0354 Elbow, ⅛-inch NPT X ⅛-inch Tube Compression 19 813-0016 Nipple, ⅛-inch NPT X Close 20 810-1006 Bushing, ¼-inch NPT to ⅛-inch NPT Reducing 21 813-0495 Tee, ¼-inch Male NPT to Female NPT 22 810-1025 Connector, ¼-inch Male NPT to ⅜-inch Tube 23 810-1026 Tee, ¼-inch Male NPT to Female NPT Street

Filter Associated Wiring 1
ITEM PART # COMPONENT 1 807-3584 Cable, Filter Lower 9-Pin Plug to 807-2001 15-Pin (C2) Connector 2 807-2001 Cable, 810-3584 15-Pin C2 Connector to Component Box
ITEM PART # COMPONENT 1 806-3941SP Harness, Full Vat Gas Valve 2 806-3940SP Harness, Dual Vat Gas Valve 3 806-9678SP Plug Assembly, CE Gas Valve
Gas Valve Wiring


U.S. and Non-CE harness (shown) has two unterminated wires.
CE harness has two unterminated wires plus two additional wires with push-on terminals.
ITEM PART # COMPONENT 807-1978 U.S. and Non-CE Export Main Wiring Harness 807-2168 CE Main Wiring Harness

ITEM PART # COMPONENT 1 806-6083 Power Cord, 120V w/Grounding Plug 5 wire (w/Ring Terminals, no Clamp) 2 807-1696 Power Cord, CE 3 807-1560 Strain Relief 4 106-1020 Pump Motor to Transfer Box Wiring Assembly



ITEM PART # COMPONENT 1 106-1011 Cable Assembly, Transformer Box Line (See NOTE 1) 2 106-1016 Cable Assembly, Transformer Box to Filter Pump (See NOTE 2) 3 106-3821 Cable Assembly, Transformer Box #2 Position (See NOTE 7) 4 106-3820 Cable Assembly, Transformer Box #1 Position (See NOTE 3) 5 106-3316 Cable Assembly, Transformer Box Line (See NOTE 4) 6 106-4990 Cable Assembly, Transformer Box Line (See NOTE 8) 7 106-3825 Cable Assembly, Transformer Box #3 Position (See NOTE 5) 8 106-3826 Cable Assembly, Transformer Box to Filter Pump (See NOTE 5) 9 106-3827 Cable Assembly, Transformer Box #1 Position (See NOTE 5) 10 106-4894 Cable Assembly, Transformer Box to Filter Pump (See NOTE 6) 11 106-4893 Cable Assembly, Transformer Box Line (See NOTE 6) NOTE 1: Item 1 is used in transformer boxes B and D on page 2-19. NOTE 2: Item 2 is used in transformer boxes A, B and D on page 2-19. NOTE 3: Item 4 is used in transformer boxes A, B, D and E on page 2-19. NOTE 4: Item 5 is used in transformer boxes C and F on pages 2-19 and 2-20. NOTE 5: Items 7, 8 and 9 are used in transformer boxes C, F and G on pages 2-19 and 2-20. NOTE 6: Items 10 and 11 are used in transformer box E on page 2-19. NOTE 7: Item 3 is used in transformer boxes A-F on pages 2-19 and 2-20. NOTE 8: Item 6 is used in transformer box G on page 2-20.


ITEM PART # COMPONENT 1 807-1068 2-Pin Female 2 807-0158 6-Pin Female 3 807-0156 9-Pin Female 4 807-0159 12-Pin Female 5 807-0875 15-Pin Female 6 807-1067 2-Pin Male 7 807-0157 6-Pin Male 8 807-0155 9-Pin Male 9 807-0160 12-Pin Male 10 807-0804 15-Pin Male 11 826-1341 Terminal, Female Split Pin (Pkg of 25) 12 826-1342 Terminal, Male Split Pin (Pkg of 25) 13 807-2518 Plug, Mate-N-Lock (Dummy Pin) * Not illustrated.




Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135
1-800-551-8633 819-6094 MAY 2006
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.