LOV™ ELECTRIC FRYER
This equipment chapter is to be installed in the Fryer Section of the
FOR YOUR SAFETY Do Not Store or use gasoline or other
Equipment Manual.
flammable vapors and liquids in the vicinity of this or any other appliance.


BY
8700 Line Avenue SHREVEPORT, LOUISIANA 71106
1-800-24 FRYER FAX: 1-318-688-2200
Frymaster L.L.C., 8700 Line Avenue, Shreveport, LA 71106
PRINTED IN THE UNITED STATES SERVICE HOTLINE
1-800-24-FRYER MAY 2011
www.frymaster.com email: [email protected] *8196446*

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS MANITOWOC FOOD SERVICE EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
U.S. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.
CANADA This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications. Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.


Frymaster, L.L.C. makes the following limited warranties to the original purchaser only for this equipment and replacement parts:
The frypot has a lifetime parts and labor warranty. If a frypot develops a leak after installation, Frymaster will replace the frypot, allowing up to the maximum time per the Frymaster time allowance chart hours of straight-time labor. Components attached to the frypot, such as the high-limit, probe, gaskets, seals, and related fasteners, are also covered by the lifetime warranty if replacement is necessitated by the frypot replacement. Leaks due to abuse or from threaded fittings such as probes, sensors, high-limits, drain valves or return piping are not included.
All defective in-warranty parts must be returned to a Frymaster Authorized Factory Service Center within 60 days for credit. After 60 days, no credit will be allowed.
This warranty does not cover equipment that has been damaged due to misuse, abuse, alteration, or accident such as: • improper or unauthorized repair (including any frypot which is welded in the field);

This warranty also does not cover: • transportation or travel over 100 miles/160 km (50 miles/80 km each way), or travel over two hours;
There are no implied warranties of merchantability or fitness for any particular use or purpose. This warranty is applicable at the time of this printing and is subject to change.






CHAPTER 1: SERVICE PROCEDURES
1.1 General Before performing any maintenance on your Frymaster fryer, disconnect the fryer from the electrical power supply.
When electrical wires are disconnected, it is recommended that they be marked in such a way as to facilitate re-assembly. 1.2 Replacing a Computer 1. Disconnect the fryer from the electrical power supply. 2. The computer bezel is held in place by tabs at the top and bottom. Slide the metal bezel up to disengage the lower tabs. Then slide the bezel down to disengage the upper tabs. 3. Remove the two screws from the upper corners of the control panel. The control panel is hinged at the bottom and will swing open from the top. 4. Unplug the wiring harnesses from the connectors on the back of the computer, marking their position for reassembly, and disconnect the grounding wires from the terminals. Remove the computer panel assembly by lifting it from the hinged slots in the control panel frame.


5. Install the replacement computer. Reinstall the control panel assembly by reversing steps 1 thru 4. 6. Setup the computer following the instructions on page 4-9 in the Installation and Operation manual. Setup MUST be performed after replacement. 7. Once setup is complete on all replaced computers, reset all control power following the instructions in section 1.11.7 on page 1-22 to readdress the new M3000 computer. Check software version and if necessary update the software. If a software update was necessary, follow the instructions to update the software in section 1.15 1.3 Replacing Component Box Components 1. Disconnect the fryer from the electrical power supply. 2. The computer bezel is held in place by tabs at the top and bottom. Slide the metal bezel up to disengage the lower tabs. Then slide the bezel down to disengage the upper tabs.

3. Remove the two screws from the upper corners of the computer and allow the computer to swing down. 4. Unplug the wiring harnesses and disconnect the grounding wires from the terminals on the back of the computer. Remove the computer assembly by lifting it from the hinge slots in the control panel frame. 5. Disconnect the wiring from the component to be replaced, being sure to make a note of where each wire was connected. 6. Dismount the component to be replaced and install the new component, being sure that any required spacers, insulation, washers, etc. are in place.
NOTE: If more room to work is required, the control panel frame assembly may be removed by removing the hex-head screws which secure it to the fryer cabinet (see illustration below). If this option is chosen, all computer assemblies must be removed per steps 1 thru 4 above. The cover plate, on the lower front of the component box, may also be removed to allow additional access if desired.

Removing the Control Panel Frame and Top Cap Assembly 7. Reconnect the wiring disconnected in step 5, referring to your notes and the wiring diagrams on the fryer door to ensure that the connections are properly made. Also, verify that no other wiring was disconnected accidentally during the replacement process. 8. Reverse steps 1 through 4 to complete the replacement and return the fryer to service.

1.4 Replacing a High-Limit Thermostat 1. Remove the filter pan and lid from the unit. Drain the frypots into an McDonald’s Shortening Disposal Unit (MSDU) or other appropriate METAL container using the computer “drain to pan option” or using the MIB board in manual mode.
DANGER DO NOT drain more than one full frypot or two split frypots into the MSDU at one time. 2. Disconnect the fryer from the electrical power supply and reposition it to gain access to the rear of the fryer. 3. Remove the four screws from both the left and right sides of the lower back panel. 4. Locate the high-limit that is being replaced and follow the two-black wires to the 12-pin connector C-6. Note where the leads are connected prior to removing them from the connector. Unplug the 12-pin connector C-6 and using a pin-pusher push the pins of the high-limit out of the connector. 5. Carefully unscrew the high-limit thermostat to be replaced. 6. Apply Loctite™ PST 567 or equivalent sealant to the threads of the replacement and screw it securely into the frypot. 7. Insert the leads into the 12-pin connector C-6 (see illustration below). For full-vat units or the left half of a dual-vat unit (as viewed from the rear of the fryer) the leads go into positions 1 and 2 of the connector. For the right half of a dual-vat unit (as viewed from the rear of the fryer), the leads go into positions 7 and 8. In either case, polarity does not matter.
8. Reconnect the 12-pin connecting plug C-6. Use wire ties to secure any loose wires. 9. Reinstall the back panels, contactor plug guards, reposition the fryer under the exhaust hood, and reconnect it to the electrical power supply to return the fryer to service. 1.5 Replacing a Temperature Probe 1. Lift the element out of the oil. 2. Disconnect the fryer from the electrical power supply and reposition it to gain access to the rear of the fryer. 3. Remove the four screws from both sides of the lower back panel. Then remove the two screws on both the left and right sides of the back of the tilt housing. Lift the tilt housing straight up to remove from the fryer.

6. Gently pull on the temperature probe and grommet, pulling the wires up the rear of the fryer and through the element tube assembly. 7. Insert the replacement temperature probe (wires first) into the tube assembly ensuring that the grommet is in place. Secure the probe to the elements using the bracket which was removed in Step 5 and the metal tie wraps which were included in the replacement kit. 8. Route the probe wires out of the tube assembly following the element wires down the back of the fryer through the Heyco bushings to the 12-pin connector C-6. Secure the wires to the sheathing with wire ties. Attach the ground clip. 9. Insert the temperature probe leads into the 12-pin connector C-6 (see illustration below). For full- vat units or the right half of a dual-vat unit (as viewed from the rear of the fryer) the red (or yellow) lead goes into position 3 and the white lead into position 4 of the connector. For the left half of a dual-vat unit (as viewed from the rear of the fryer), the red (or yellow) lead goes into position 9 and the white lead into position 10. NOTE: Right and left refer to the fryer as viewed from the rear.
Probe Leads · Probe Bracket · Metal Wire Tie

1.6 Replacing a Heating Element 1. Perform steps 1-5 of section 1.5, Replacing a Temperature Probe. 2. Disconnect the wire harness containing the probe wiring, where the temperature probe is attached to the element being replaced. Using a pin pusher, disconnect the probe wires from the 12-pin connector. 3. In the rear of the fryer disconnect the 6-pin connector for the left element (as viewed from the front of the fryer) or the 9-pin connector for the right element from the contactor box. Press in on the tabs on each side of the connector while pulling outward on the free end to extend the connector and release the element leads (see photo below). Pull the leads out of the connector and out of the wire sleeving.

4. Raise the element to the full up position and support the elements. 5. Remove the hex head screws and nuts that secure the element to the tube assembly and pull the element out of the frypot. NOTE: The nuts inside the tube can be held and removed using the RE element tube nut spanner, PN# 2304028. Full-vat elements consist of two dual-vat elements clamped together. For full-vat units, remove the element clamps before removing the nuts and screws that secure the element to the tube assembly. 6. If applicable, recover the probe bracket and probe from the element being replaced and install them on the replacement element. Install the replacement element in the frypot, securing it with the nuts and screws removed in Step 5 to the tube assembly. Ensure the gasket is between the tube and element assembly. 7. Route the element leads through the element tube assembly and into the wire sleeving to prevent chafing. Ensure that the wire sleeving is routed back through the Heyco bushing, keeping it clear from the lift springs (see photos next page). Also ensure that the wire sleeving extends into the tube assembly to protect the edge of the tube assembly from chafing the wires. Press the pins into the connector in accordance with the diagram on the following page, and then close the connector to lock the leads in place. NOTE: It is critical that the wires be routed through the sleeving to prevent chafing.

Index Marker marks Position 1
5 R 4R 6 R 1R 2 R 3R
Full vat element wire routing

Pull the element wires through the bushings on either side of the frypot and down the back. Element wires should be routed to the right of the ATO temperature probe on the back wall of the frypot.

Pull the element wires through the bushings on either side of the frypot and down the back. Element wires should be routed to the center of the frypot between the ATO temperature probes.
Element grounding and wire routing To ground the element wires, use the hole in the frypot frame located under the bushing that the element wires pass through. Using a screw through the ground wires ring terminal, connect it to the frypot using the probe ground clip. Use a tie wrap to tie up half of the element wires after the wires are pulled through the bushing. Do not pull tie wrap tight, leave it slack at about one inch


8. Reconnect the element connector ensuring that the latches lock. 9. Insert the temperature probe leads into the 12-pin wiring harness connector (see illustration below). For full-vat units or the right half of a dual-vat unit, the red lead goes into position 3 and the white into position 4. For the left half of a dual-vat unit, the red lead goes into position 9 and the white into position 10. NOTE: Right and left refer to the fryer as viewed from the rear.
10. Reconnect the 12-pin connector of the wiring harness disconnected in Step 2. 11. Lower the element to the full down position. 12. Reinstall the tilt housing, back panels and contactor plug guard. Reposition the fryer under the exhaust hood, and reconnect it to the electrical power supply. 1.7 Replacing Contactor Box Components 1. If replacing a contactor box component in boxes above the filter pan, first remove the filter pan and lid from the unit. If replacing components in fryers tht have ATO boxes, the ATO box may require removal. 2. Disconnect the fryer from the electrical power supply. 3. Remove the two screws securing the cover of the contactor box. The contactor boxes above the filter pan are accessed by sliding under the fryer. They are located to the left and right above the guide rails (see photo below). The contactor boxes for frypots not over the filter pan are accessed by opening the fryer door directly under the affected frypot.

Remove two screws to access contactor box components above the filter pan.



Left and right views of mechanical contactor box components. Sometimes it is necessary to remove the entire contactor box to repair. Below are the instructions for removing the far left contactor box. 1. Remove fryers from hood and remove all power to fryers. 2. Remove lower back panel. 3. Remove filter pan, lid and downspout splash shield. 4. Remove clevis clip from dispose handle at rear of fryer and let handle drop out of waste valve bracket. 5. Remove two screws holding waste valve handle at front of fryer and remove bracket and handle from fryer. 6. Remove AIF board and tuck wires out of the way of the contactor box for box removal. 7. Remove shipping brace that supports filter pump shelf brace to top of contactor box. 8. Remove contactor box cover. 9. Unplug all wiring from front and rear of contactor box. 10. Remove two screws that hold element wire shield to rear of contactor box and remove wire shield. 11. Remove two screws that support contactor box at rear of box. 12. Remove two screws that support contactor box at front of box. 13. Lift contactor box up to clear left frame rail and slide to the right far enough that the left rear corner of the pump and motor shelf protrude inside of the contactor box slightly. 14. Tip front of contactor box down and to the right slightly and then pull out from opening where filter pan lid would rest. 15. Reverse above steps for reinstallation. 1.8 Replacing a Frypot 1. Drain the frypot into the filter pan or, if replacing a frypot over the filter system, into a McDonald’s Shortening Disposal Unit (MSDU) or other appropriate METAL container. If replacing a frypot over the filter system, remove the filter pan and lid from the unit.

3. Slide the metal bezel up to release the bottom tabs, then slide the bezel down to disengage the upper tabs. 4. Remove the two screws from the upper corners of the computers and allow them to swing down (see illustration and photo on page 1-1). 5. Unplug the wiring harnesses and ground wires from the backs of the computers. Remove the computers by lifting them from the hinge slots in the control panel frame. 6. Remove the tilt housing and back panels from the fryer. The tilt housing must be removed first in order to remove the upper back panel. 7. To remove the tilt housing, remove the hex-head screws from the rear edge of the housing. The housing can be lifted straight up and off the fryer. 8. Remove the control panel by removing the screw in the center and the nuts on both sides. 9. Loosen the component boxes by removing the screws, which secure them in the cabinet. 10. Dismount the top cap by removing the nuts at each end that secure it to the cabinetry. 11. Remove the hex head screw that secures the front of the frypot to the cabinet cross brace. 12. Remove the top-connecting strip that covers the joint with the adjacent frypot. 13. Unscrew the nut located on the front of each section of drain tube, and remove the tube assembly from the fryer. 14. Remove the actuators from the drain and return valves and disconnect the wiring. 15. Disconnect any auto filtration probes and auto top off sensors and wiring. 16. At the rear of the fryer, unplug the 12-pin connector C-6 and, using a pin pusher, disconnect the high-limit thermostat leads. Disconnect any other probe wiring. 17. Disconnect the oil return flexline(s). 18. Raise the elements to the “up” position and disconnect the element springs. 19. Remove the machine screws and nuts that secure the element tube assembly to the frypot. Carefully lift the element assembly from the frypot and secure it to the cross brace on the rear of the fryer with wire ties or tape. 20. Carefully lift the frypot from the fryer and place it upside down on a stable work surface. 21. Recover the drain valve(s), oil return flexline connection fitting(s), actuators, AIF boards and high- limit thermostat(s) from the frypot. Clean the threads and apply Loctite™ PST 567 or equivalent sealant to the threads of the recovered parts and install them in the replacement frypot. 22. Carefully lower the replacement frypot into the fryer. Reinstall the hex head screw removed in step 11 to attach the frypot to the fryer.

23. Position the element tube assembly in the frypot and reinstall the machine screws and nuts removed in step 19. 24. Reconnect the oil return flexlines to the frypot, and replace aluminum tape, if necessary, to secure heater strips to the flexlines. 25. Insert the high-limit thermostat leads disconnected in step 16 (see illustration on page 1-3 for pin positions). 26. Reconnect the actuators, ensuring the correct position of the drain and return valves. 27. Reconnect the auto filtration and auto top off probes. 28. Reinstall the drain tube assembly. 29. Reinstall the top connecting strips, top cap, tilt housing and back panels. 30. Reinstall computers in the control panel frame and reconnect the wiring harnesses and ground wires. 31. Reposition the fryer under the exhaust hood and reconnect it to the electrical power supply. 1.9 Built-in Filtration System Service Procedures 1.9.1 Filtration System Problem Resolution One of the most common causes of filtration problems is placing the filter pad/paper on the bottom of the filter pan rather than over the filter screen.
malfunction.
Whenever the complaint is “the pump is running, but no oil is being filtered,” check the installation of the filter pad/paper, and ensure that the correct size is being used. While you are checking the filter pad/paper, verify that the O-rings on the pick-up tube of the filter pan are in good condition. A missing or worn O-ring allows the pump to take in air and decrease its efficiency. If the pump motor overheats, the thermal overload will trip and the motor will not start until it is reset. If the pump motor does not start, press the red reset switch (button) located on the rear of the motor. If the pump starts after resetting the thermal overload switch, then something is causing the motor to overheat. A major cause of overheating is when several frypots are filtered sequentially, overheating the pump and motor. Allow the pump motor to cool at least 30 minutes before resuming operation. Pump overheating can be caused by:



Disconnect flexlines indicated by the arrows.
4. Loosen the nut and bolt which secure the bridge to the oil-return manifold. 5. Remove the cover plate from the front of the motor and disconnect the motor wires. 6. Remove the two nuts and bolts which secure the front of the bridge to the cross brace and carefully slide the bridge rearward off the cross brace until its front end can be lowered to the floor. Undo the single nut holding it in place in back. Be careful not to let the rear of the bridge slip off the manifold at this point. 7. Get a good grip on the bridge, carefully pull it forward off the oil-return manifold, and lower the entire assembly to the floor. Once on the floor, pull the assembly out the front of the fryer. 8. When required service has been completed, reverse steps 4-7 to reinstall the bridge. 9. Reconnect the unit to the electrical power supply, and verify that the pump is functioning correctly using the MIB board in manual mode (i.e., using the fill function when engaged, the motor should start and there should be strong suction at the intake fitting and outflow at the rear flush port.) 10. When proper operation has been verified, reinstall the back panels and the filter pan and lid. 11. Reconnect it to the electrical power supply and reposition the fryer under the exhaust hood to return the fryer to service. 1.9.3 Replacing the Transformer or Filter Relay Disconnect the fryer from the electrical power supply. Remove the left computer from the fryer to expose the interior of the left component box. The transformer and relay on the left are located as shown in the illustration on the next page. NOTE: The right component box is identical to the left except that the transformer and relay on the left side are not present. Once replaced, reconnect the power. When replacing a filter relay in the left component box, ensure the 24VDC relay (8074482) is used. Similar Frymaster fryers use a 24VAC relay, which can lead to confusion. The 24VDC is used in the LOV™ fryer.

1.10 ATO (Automatic Top-off) Service Procedures The automatic top-off system is activated when the oil level falls below a sensor in the rear of the frypot. The signal is sent to the ATO board to engage the return actuator to the frypot and turn on the ATO pump. The pump draws oil from the JIB (Jug In Box) through the rear return manifold into the rear of the frypot. Once the oil level has satisfied the sensor, the pump turns off and the actuator closes. The ATO board is located inside the box, behind the JIB (see Figure 1). The power for the ATO board is supplied from the right hand component box. The power passes through the transformer inside the ATO box to the board.

Problem Probable Causes Corrective Action Frypot tops off cold. Incorrect setpoint Ensure setpoint is correct.
A. Check to ensure J5 on front of ATO
board is fully locked into connector. B. Ensure fuse below right control box is
A. J5 connection unplugged B. Fuse blown C. Transformer malfunction
No power to ATO board
not blown and fuse on the right side of ATO box is not blown. C. Check that proper voltage is present at
transformer. See table in section 1.10.2.
A. Loose wire connection B. Power in the component box is not
A. Ensure the yellow LED is securely
attached to plug J6 on the ATO board. B. Ensure power is present in the
The yellow JIB low light
won’t illuminate.
present. C. Failed transformer.
component box. C. If power is present in component box,
check the transformer for correct voltage.
A. Loose wire connection. B. Actuator issue
A. Ensure all wiring harnesses are securely
One vat tops off but other vats fail to top off.
connected to ATO board and solenoids. B. Check return actuator to ensure actuator
is functional.
Incorrect vat tops off. A. Wired incorrectly.
A. Check wiring. B. Switch flexlines to correct vat.
B. Flexlines connected to wrong vat.

A. Ensure JIB has oil. B. Check to see that fryer is heating.
Fryer temperature must be at setpoint. Check probe resistance. If probe is bad, replace the probe. C. Ensure that the oil in the JIB is above
A. Empty JIB. B. Probe temperature lower than setpoint. C. Oil is too cold. D. Bad Connection E. ATO board power loss F. Failed transformer/harness G. ATO pump failed H. Failed ATO board.
70°F (21°C). D. With the computer OFF, press TEMP
button and ensure the ATO software version appears. If not, the connection between the AIF and the ATO board may be bad. Ensure the 6-pin CAN connectors are tight between AIF (J4 and J5) and ATO (J10) boards. E. Power to the ATO board has been cut
Frypots won’t top off.
off. Restore power to the board and clear any service required errors. F. Ensure transformer in ATO box is
functioning properly. Check power from transformer to ATO board. Ensure all harnesses are plugged securely into place. G. Ensure pump is operational. Check
I. ATO lines/pump plugged
voltage to pump. Replace the pump if defective. H. Check for proper voltages using the pin
position chart found on page 1-15. If ATO found defective, replace ATO board and clear any errors. I. Clear the lines/pump.
A. Clear filter error properly. When
change filter pad YES/NO is displayed, do NOT press any button until the pan has been removed for at least thirty seconds. After thirty seconds have elapsed, the computer returns to OFF or last display. B. Check actuator, ATO pump, wire
A. Filter error exists. B. Actuator, pump, loose connection, RTD
One vat doesn’t top off.
or ATO issue.
connections, RTD and ATO board.
A. Ensure fuse on right side of ATO box is
secure and good. If the computer above the ATO box is missing power check the fuse below the component box. B. With the computer OFF, press TEMP
button and ensure the ATO software version appears. If not, the connection between the AIF and the ATO board may be bad. Ensure the 6-pin CAN connectors are tight between AIF (J4 and J5) and ATO (J9 or J10) boards. C. Power to the ATO board has been cut
A. Loose or bad fuse B. Bad Connection C. ATO Board power loss
BOARD
off. Ensure there is correct voltage to the ATO transformer. Restore power to the board and clear any service required errors.
M3000 displays

1.10.2 ATO (Automatic Top-Off) Board Pin Positions and Harnesses
Connector From/To Harness #
1 24VAC Ret 24VAC Black
2 3 ATO Pump Relay 4 24VAC Ret 24VAC Black
6 7 JIB Reset Switch 8 JIB Low Reset 16VDC Black RTI Add Solenoid 9 24VAC 24VAC Red
10 11 ATO Pump Relay 12 24VAC 24VAC Red
14 15 JIB Reset Switch 16 Ground 16VDC Red
1 24VAC Ret 24VAC Orange 2 24VAC Blue 3 4 5 12VAC Ret 12VAC Red 6 12VAC Brown ATO 4 & 5 Battery Jumper 8074657 7 Jumper Ohm Black 8 Jumper Black
1 DV - Probe Ground
White 2 DV - Probe Red 3 FV - Probe Ground White 4 FV - Probe Red
J3 - Vat #3 J2 - Vat #2 J1 - Vat #1
8074655 - Vat #1 8074654 - Vat #2 8074621 - Vat #3
J6 Orange LED 8074555 1 16VDC 16VDC Black 2 16VDC Ret Red
2 3 Ground 4 RB7/DATA 5 RB6/CLOCK
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5VDC+ 5VDC Black 5 24VDC 24VDC Red 6 Ground White
(pins 2 & 3) or to next ATO Board (4
& 5 vat units)
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5VDC+ 5VDC Black 5 24VDC 24VDC Red 6 Ground White

1.10.3 Replacing the ATO board, LON Gateway, ATO pump relay or Transformers
Disconnect the fryer from the electrical power supply. Locate the ATO box (see Figure 1 on page 12), behind the JIB (Jug In Box). Remove the cover to expose the transformers, relay and LON gateway (if installed) (see Figure 2). Mark and unplug any wires or harnesses. Once the LON gateway is removed the ATO board is visible (see Figure 3). Replace the defective component and reattach all wires or harnesses. Replace the cover. Once replaced, CYCLE POWER TO ENTIRE FRYER SYSTEM. See section 1.11.7 on page 1-22 to reset control power. Check software version and if necessary update the software. If a software update was necessary, follow the instructions to update the software in section 1.15


Figure 2 Figure 3
Press the TEMP button on one of the M3000 computers, with the computer in the OFF position, to verify software version of the ATO. If the version is not visible, the ATO may not be connected properly. 1.10.4 Replacing the ATO Pump
Disconnect the fryer from the electrical power supply. Locate the ATO pump (see Figure 4), behind the ATO box. Mark and unplug any wires or harnesses. Press up from the bottom on the quick disconnects to release the plumbing (see Figure 5). The plumbing can be pulled from the pump. Loosen the four nuts attaching the pump to the pump tray. Replace the defective component and reverse above steps. Once replaced, reconnect the power.


Figure 4 Figure 5
The MIB (Manual Interface Board) oversees and controls filtration. It receives and sends data over the CAN (Controller Area Network) to and from various sensors and computers. It activates the filtration cycle, controlling when actuators should open and close. The MIB controller is located inside the left cabinet (see Figure 6). In normal operation a cover hides the MIB controls and only the LED display is visible. The cover is held in place with three torx screws. In normal operation, an “A” is displayed for automatic mode. The MIB control board is useful for diagnostic purposes. It allows manual operation of both the actuators and filter pump without using the M3000 computer.


Reset Switch Drain Switch Return Switch
Figure 6: MIB controller cover.

Buttons and LED’s Manual – This button is used to toggle between auto and manual filtration mode. A corresponding LED is lit when in Manual mode. When pressed, a message will be sent to all vats, indicating the mode has changed. The following buttons are inoperable in auto mode: Select - This button is used to scroll through available vats, choosing one to be manually filtered. Drain – This button is used to open and close the drain on the vat indicated on the display. It’s embedded LED indicates the following activity: Blink: Actuator is moving or awaiting a response from the AIF board. Constant Illumination: Drain open. No Illumination: Drain closed. Return – This button is used to open and close the return valve on the vat indicated on the display. When pressed and held, it also turns on and off the pump. It’s embedded LED indicates the following activity: Blink: Actuator is moving or awaiting a response from the AIF board. Constant Illumination: Return valve open. No Illumination: Return valve closed.
1.11.1 Manually Draining, Refilling or Filtering using the MIB board Press the manual/auto switch to set to manual. The LED on the manual key will illuminate and a vat number is displayed (see Figure 8).
Press the vat selector switch to change vats (see Figure 9).
Pressing the drain or the return switch illuminates and activates the drain or return valve for the vat indicated. Pressing and holding the return switch while the return is open activates the filter motor and pump (see Figure 10). Pressing the manual/auto switch will return to automatic mode.

1.11.2 MIB (Manual Interface Board) Troubleshooting
A. Ensure filter pan is fully inserted into fryer.
A. Filter pan out of position. B. Oil level too low. C. Ensure MIB board is not in
If the MIB board displays a “P” the pan is not fully engaged into the pan switch. B. Ensure the oil level is above the top oil
manual mode. D. Ensure MIB cover is not
level sensor. C. Ensure MIB board is in “A” automatic
damaged and pressing against buttons. E. Filter relay has failed. F. AIF disable is set to YES, blue
mode. D. Remove and replace cover and see if
start.
filtration will start. E. Replace filter relay with part number 807-
light doesn’t light. G. Filter motor thermal switch is
4482 24VDC relay. F. Set AIF disable in Level 1 to NO. G. Press filter motor thermal switch. H. Ensure AIF clock is set to disabled. MIB display shows something other than an “A” or vat number.
tripped. H. AIF clock enabled
An error has occurred and displayed character indicates error.
See MIB display diagnostics on page 1-21 for explanation.
Check output on the left transformer in left component box; should read 24VAC. If not replace transformer.
No power present at
Transformer has failed in left component box.
Press and hold reset button in top right corner of MIB board for five seconds. The drain, return and manual/auto LEDS will illuminate and the MIB will reset and clear any remaining errors from memory. Allow 60 seconds to reset. If an error still exists, then another issue exists.
MIB will not clear
Error remains in non-volatile memory.
error.
A. Ensure the CAN bus system is terminated at
BOTH ENDS (on the M3000 connector J6 and on the ATO board connector J9) with a resistor equipped 6-pin connector. B. Unplug and reseat all wiring harnesses in
CAN system. Resistance between pins 2 and 3 on the CAN network connectors should be 120 ohms. C. Check software version numbers on all
A. Network is not terminated
correctly. B. Wiring harnesses are loose or
MIB indicates incorrect number of
M3000 computers and ensure all are display an AIF version. If an AIF version is missing, the AIF board may be missing power or bad. Check pins 5 and on J4 and J5 of the affected AIF board for proper voltage. D. The locator pin in J2 of the AIF board is
damaged. C. An AIF board issue. D. Locator pin issue.
vats.
either loose or in the incorrect position. See the charts on page 1-55 of this manual for proper pin position.
Auto filtration won’t · the MIB board

A. Ensure the CAN bus system is terminated at
BOTH ENDS (on the M3000 connector J6 and on the ATO board connector J10) with a resistor equipped 6-pin connector. B. With the computer OFF, press TEMP button
and ensure the AIF version appears. If not, the 24V to the AIF boards may be missing. Ensure all 6-pin CAN connectors are tight between the M3000 (J6 and J7), MIB (J1 and J2), AIF (J4 and J5) and ATO (J10) boards. C. With the computer OFF, press TEMP button
and ensure the ATO version appears. If not, check the CAN wire harness between the AIF board J4 or J5 and the ATO board J9 or J10. The ATO fuse on the right side of the ATO box may be loose or blown; the 110V to the ATO transformer may be missing or the transformer bad. The J4/J5 connector may be loose. Is the right computer functioning? If not the fuse below the contactor box may be loose or blown. D. Check to see if MIB has 24V on pins 5 and
Network error on the CAN bus communication.
“E” and “vat number
6 of J2. Check to see if 24V is present on pins 5 and 6 of wire harness plugging into J4 or J5 of the first AIF board. If 24V missing, check the pins. Replace the harness if necessary. E. Check continuity between each color wire
and side”.
on the CAN connectors into J7 on the far right computer and J10 on back of the ATO board (black to black, white to white, and red to red), and ensure there is no continuity between different color wires (black to red, red to white, and white to black). F. Ensure black computer locator wires are
connected from ground to correct pin position (see drawing 8051734 page 1-55). G. Ensure all boards have the corner ground
wire attached and tightened. H. The locator pin in J2 of the AIF board is
either loose or in the incorrect position. See the charts on page 1-55 of this manual for proper pin position. I. Bad MIB and/or AIF board. J. Broken resistor lead. Unwrap the resistor
leads and check ends.
MIB board alternating

Connector From/To Harness # Pin # Function Voltage Wire Color
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5VDC+ 5VDC Black 5 24VDC 24VDC Red 6 Ground White
1 24VAC 24VAC Black 2 24VAC Ret White
Filter Relay 3 Pump Motor 24VDC Red 4 Pump Motor Green
Blue LED 5 Blue LED + 24VDC Red 6 Blue LED - Black RTI Open Switch 7 Open Switch + Black RTI Closed Switch 8 Closed Switch + Red
J5
8074844 NON-RTI
Pan Switch 11 Pan Sw + 24VDC Black 12 Pan Sw - Red
13 14 RTI Open Switch 15 Ground - White RTI Closed Switch 16 Ground - Green
1 From RTI transformer 24VAC Black 2 Common White 3 To RTI "Add Pump" Relay 24VAC Green 4
J6 To RTI connection in
rear of fryer 8074760
24VAC – Full 0VAC – Not Full Red
From RTI "Waste Tank Full Sensor" Test Pins 2 to 8
Transformer

DISPLAY LED EXPLANATION Drain Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
On Drain valve on vat # is open
Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Off Drain valve on vat # is closed
Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Blink Drain valve on vat # is opening or closing or an error condition may exist.
Return Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
On Return valve on vat # is open
Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Off Return valve on vat # is closed
Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Blink Return valve on vat # is opening or closing or an error condition may exist
Network N Network error, displays for 10 seconds if no communications are received from the M3000 within 10 seconds after power on or MIB reset. Resetting r An “r” is displayed for ten seconds or until communication is received from the M3000 after a power on or MIB reset. Miscellaneous E alternating with vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Blink The circuit has an issue. Ensure the actuator is plugged in. Ensure the CAN connections are all securely plugged into the connectors.
Indicates the AIF temperature sensor did not detect a full vat during filtration.
A Manual LED off The system is in auto filtration mode. Vat # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.)
Manual LED on The system is in manual mode.
P This will only be displayed in auto filtration mode. Filter pan is improperly seated. Any auto filtration messages received at this time are ignored.

A – Auto Mode – Auto Filtration enabled.
E – Drain or return valve is not in desired state. The display will alternate between E and the corresponding vat number. Ensure the actuator is plugged in and an error does not exist.
– Three horizontal lines indicate the AIF temperature sensor did not detect that the vat was full during auto filtration.
n – Network Error - An “n” displays for 10 seconds if no communication is received from the cooking computer within ten seconds after a power on or MIB reset.
P – Pan Switch – Filter pan is improperly seated. Filtration is suspended.
r – Reset Switch - Reset the vat closes all of the valves on the vat. If displayed for some time, there is probably a problem with the board. 1 – 5 – Numbers which correspond to the vats with either an “L” indicating the left side of a split vat or “r” indicating the right side of a split vat or a full vat. These numbers are displayed in manual mode. 1.11.6 Replacing the MIB Board
Disconnect the fryer from the electrical power supply. Remove the torx screws from the MIB cover, exposing the MIB board (see Figure 11). Removing the screw at top center lets the MIB board hinge down. Carefully remove the plugs on the rear of the board (see Figure 12). Replace with a new MIB board and reverse steps to reassemble. Once replaced, CYCLE POWER TO ENTIRE FRYER SYSTEM. See next section to reset control power. Check software version # and if necessary update the software. If a software update was necessary, follow the instructions to update the software on in section 1.15 ensuring the MIB reset button is pressed and held for five seconds at the end of the update to update the MIB.


Figure 12 1.11.7 Control Power Reset Switch The control power reset switch is a momentary rocker switch located behind the control box (see Figures 13 and 14) above the JIB that resets all power to all the computers and boards in the fryer. It is necessary to reset all power after replacing any computer or board. Press and hold the switch for at least ten seconds when resetting the control power to ensure power has sufficiently drained from boards.


Figure 13 Figure 14 (Rear view of Control Box)

1.12 RTI Service Issues 1.12.1 RTI MIB Tests The LOV™ fryer will ONLY operate with RTI systems that have the new RTI updated three-pole float switch. If the float switch is the older two-pole switch, call RTI. These float switches are polarity specific which may short to ground and damage an MIB board. Normal measurements (MIB J6 8-pin connector with everything connected) AC voltage measurements: Pin 1 to Pin 2 - 24 VAC. Pin 2 to Pin 8 - 24 VAC when waste tank is full, 0 VAC when it is not full. Pin 2 to Pin 3 - 24 VAC when RTI fill pump is on, 0 VAC when it is off. Using the RTI test box, PN# 108-0716 allows a quick and easy way to check the 24VAC, the waste full switch and when the RTI pump is operating. Troubleshooting All return and drain valves should be closed and pump should be off while the MIB is resetting. If any of the valves or the pump is on during reset, the MIB board is bad or wires are shorted. RTI pump is not operating or JIB is not filling: See page 1-26 to ensure that no other function is taking priority over adding oil to jug. 1. Reset the power; wait 60 seconds and see if the valve opens. With the JIB button pressed: 2. Voltage at MIB board from Pin 1 to Pin 2 should be 24 VAC; if not, check connections from RTI 24VAC transformer and check transformer. 3. Voltage at MIB board from Pin 1 to Pin 3 should be 24 VAC when filling JIB or vat; if not, the MIB board is bad or wires to pump relay are shorted or both. 4. Voltage at Add pump relay should be 24 VAC; if not, check wiring from MIB board. The relay is located on top of RTI system. 5. Check voltage at ATO board on J8. Pin 9 to Pin 1 should be 24 VAC with the orange button pressed. Waste full signal: Pin 2 to Pin 8 should be 24 VAC when full, 0 VAC when not full; if no voltage level change, the connection from RTI switch or MIB board is bad.




1.12.4 RTI LOV™ TEST QUICK REFERENCE DISPOSE TO WASTE, REFILL VAT FROM BULK:
1. Hold down “Filter” button until computer beeps twice. 2. Scroll down to “Dispose” using “Info" button then press “9” button. 3. “Dispose? Yes/No” is displayed.* 4. Press “9” to dispose of oil in pot. 5. “Draining” is displayed. 6. “Vat Empty? Yes” is displayed. 7. Press “9”. 8. “Cln Vat Complete? Yes” is displayed. 9. Press “9”. 10. “Open Dispose Valve” is displayed. Open dispose valve. 11. “Disposing” is displayed for five minutes. 12. “Remove Pan” is displayed. Remove pan. 13. “Is Pan Empty? Yes No” is displayed. 14. Press “9” if filter pan is empty. Select “8” if pan still has oil in it. 15. “Close Dispose Valve” is displayed. Close dispose valve. 16. “Insert Pan” is displayed. Insert pan. 17. “Fill Vat From Bulk? Yes/No” is displayed. 18. Press “9”. 19. “Press and Hold Yes to Fill” alternating with “Yes” is displayed. 20. Hold down “9” to fill pot to desired level. 21. “Filling” is displayed while button is depressed. 22. “Continue Filling Yes/No” is displayed 23. Press “9” to continue filling or “8” to Exit program. *NOTE: If the waste tank is full, the computer displays “RTI Tank Full.” Call RTI. DISPOSE TO WASTE:
1. Hold down “Filter” button until computer beeps twice. 2. Scroll down to “dispose” using “Info” button and press “9” button. 3. “Dispose? Yes/No is displayed. 4. Press “9”. 5. “Draining” is displayed. 6. “Vat Empty? Yes is displayed. 7. Press “9” 8. “Cln Vat Complete? Yes” is displayed. 9. Press “9”. 10. “Open Dispose Valve” is displayed. 11. Open dispose valve by pulling completely forward to start disposal. 12. “Disposing” is displayed for four minutes. 13. “Remove Pan” is displayed. 14. Slide the filter pan slightly out of the fryer. 15. “Is Pan Empty? Yes/No” is displayed. 16. Press “9” if the filter pan is empty. Select “8” if pan still has oil in it. 17. “Close Dispose Valve” is displayed. 18. Close the dispose valve ensuring the handle is pushed completely towards the fryer. 19. “Insert Pan” is displayed. 20. “Fill Vat From Bulk? Yes/No” is displayed. 21. Press “8” if you wish to leave pot empty and exit. FILL VAT FROM BULK:

1. When “Orange” indicator light is on, the top-off jug is empty. 2. To refill jug press and hold the orange reset button above the jug until the jug is full. 3. Release the button to stop filling. *NOTE: The jug may not fill if any of the following are in progress: If FILTER NOW? YES/NO, CONFIRM YES/NO, or SKIM VAT is displayed, the fill jug button is disabled until either a filter is complete or until no is chosen. The system also checks these conditions. The following must be met before jug fill is allowed. Solenoid closed
If using two fryer systems that are both attached to the RTI system, they may not be able to fill both units at the same time if they have an RTI unit with a single head. Some RTI units have dual heads which can fill simultaneously.

The AIF (Automatic Intermittent Filtration) board controls the actuators that open and close the drain and return valve. The AIF boards are located inside a protective housing under each frypot (see Figure 13).

Figure 13 1.13.1 AIF Troubleshooting
A. Check pins 5 and 6 of J2 at the MIB
board. Should read 24VDC. Check voltage on pins 5 and 6 at the other end of harness and ensure 24VDC is present. Continue to check pins 5 and 6 for 24VDC on plugs J4 and J5 on the AIF boards. B. Ensure the actuator is plugged into the
proper connection (J1 for FV return, J3 for DV return and J6 for FV drain and J7 for DV drain). C. Check power on the connector of the
A. No power to the AIF board. B. Actuator is unplugged. C. AIF board failure. D. Actuator readings are out of tolerance. E. Actuator is bad
problem actuator while trying to manually open or close an actuator. Pins 1 (Black) and 4 (White) should read +24VDC when the actuator is opening. Pins 2 (Red) and 4 (White) should measure -24VDC when the actuator is closing). If either voltage is missing, the AIF board is likely bad. Test the actuator by plugging into another connector. If the actuator operates, replace the board. D. Check resistance of the potentiometer
function.
between pin 3 (purple wire) and pin 4 (gray/white wire). Closed should read 0-560Ω. Open should read 3.8K Ω – 6.6K Ω. E. If proper voltages are present at the
connector and actuator doesn’t operate, reset power to the fryer. If it still doesn’t operate replace the actuator.
A. Ensure the actuator is plugged into
correct connection (J1 for FV return, J3 for DV return and J6 for FV drain and J7 for DV drain). B. Ensure the locator pin is in proper
A. Actuator plugged into wrong connector. B. Locator pin is in wrong position.
wrong vat.
position in plug J2. See table B on page 1-55.
Actuator doesn’t · Actuator functions on

Connector From/To Harness PN
1 Ret + (Open) 24VDC Black 2 Ret – (Closed) 24VDC Red 3 Ret Position Purple 4 Ground White
1 Ground White 2 FV - Temp Red
DV AIF RTD 3 Ground White 4 DV - Temp Red
6 7 8 Oil Level Sensor
9 DV – OLS (Gas) 10 FV – OLS (Gas)
11 Locator Vat #5
Black 12 Locator Vat #4 13 Locator Vat #3 14 Locator Vat #2 15 Locator Vat #1 Locator 16 Locator Signal Black
1 Ret + (Open) 24VDC Black 2 Ret – (Closed) 24VDC Red 3 Ret Position Purple 4 Ground White
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5VDC+ 5VDC Black 5 24VDC 24VDC Red 6 Ground White
8074547 AIF Board Communication
J4 MIB J2 or
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4 5VDC+ 5VDC Black 5 24VDC 24VDC Red 6 Ground White
8074547 AIF Board Communication
J5 AIF J4 or
1 Drain + (Open) 24VDC Black 2 Drain – (Closed) 24VDC Red 3 Drain Position Purple 4 Ground White
J6 FV Drain Actuator N/A
1 Drain + (Open) 24VDC Black 2 Drain – (Closed) 24VDC Red 3 Drain Position Purple 4 Ground White

1.13.3 Replacing an AIF (Automatic Intermittent Filtration) board Disconnect the fryer from the electrical power supply. Locate the AIF board to be replaced under a frypot. Mark and unplug the harnesses. The AIF board assembly is held in place with one screw in the front of the assembly (see Figure 14). Remove the screw and the front of the assembly drops down (see Figure 15) and the back tab slides out of the bracket attached to the frypot (see Figure 16). Reverse steps to reassemble, ensuring that the new AIF assembly slides into the slot in the rear of the bracket. Once complete, CYCLE POWER TO ENTIRE FRYER SYSTEM. See section 1.11.7 on page 1-22 to reset control power. Check software version # and if necessary update the software. If a software update was necessary, follow the instructions to update the software in section 1.15.



Figure 14 Figure 15 Figure 16 1.13.4 Replacing a Linear Actuator Disconnect the fryer from the electrical power supply. Locate the actuator to be replaced under a frypot and mark and unplug the actuator. The actuators are held in place by two clevis pins which are held in by “J” clips (see Figure 17). Twist and remove both “J” clips and clevis pins (see Figure 18). It may be necessary to remove the AIF board to access the pins. Remove the actuator and attach the new actuator with only the rear clevis pin and “J” clip. Align the alignment holes and insert the clevis pin into both holes (see Figure 19). Rotate the actuator shaft until the holes of the shaft and valve plate align (see Figure 20). Remove the pin from the alignment hole and insert into the actuator shaft and valve handle (see Figure 21). Insert the “J” pin to secure (see Figure 22).




Figure 17 Figure 18 Figure 19 Figure 20



1.13.5 Replacing a Rotary Actuator Disconnect the fryer from the electrical power supply. Locate the actuator to be replaced and mark and unplug the actuator. The actuators are held in place by two allen screws. Loosen the allen screws. It may be necessary to remove a gas line to the burner when removing a drain actuator. Remove the actuator from the valve stem. Align the actuator with the valve stem and attach the new actuator. Tighten the two allen screws. Reconnect power and test the actuator. NOTE: Rotary actuators have two different part numbers, which are mirror images of each other that correspond to their mounting position. 1.14 M3000 Computer Service Procedures 1.14.1 M3000 Computer Troubleshooting
A. Press the ON/OFF switch to turn the
computer on. B. This fryer may have two cords: a
computer power cord and a main power cord. If the computer cord is not plugged in, the computer will not activate. Verify computer power cord is plugged in and that circuit breaker is not tripped. C. Some fryers have a rocker power switch
A. Computer not turned on. B. No power to the fryer. C. Power switch turned off. D. Loose fuse holder. E. Computer has failed. F. Damaged computer wiring harness. G. Power supply component or interface board has failed.
inside the cabinet below the computer. Ensure the switch is turned on. D. Ensure fuse holder is screwed in properly. E. Swap the computer with a computer
Computer.
known to be good. If computer functions, replace the computer. F. Swap with a harness known to be good.
If computer functions, replace the harness. G. If any component in the power supply
system (including the transformer and interface board) fail, power will not be supplied to the computer and it will not function. Computer locks up. Computer error. Remove and restore power to the computer.
A. Wait until the previous filtration cycle
ends to start another filtration cycle or until the MIB board has reset. This may take up to one minute. B. If filter busy is still displayed with no
A. Another filtration cycle is still in
process. B. Computer error.
filter busy.
activity, ensure the filter pan is empty and remove and restore ALL power to the fryer.
Silence the alarm by pressing the 9 button. Check that fryer is heating properly. Maximum recovery for electric is 1:40. If this error continues to appear call your ASA.
Recovery time exceeded maximum time limit for two or more cycles.
FAULT.
No Display on · M3000 display shows · M3000 display shows

Wrong energy type selected in setup. Press 1234 to enter setup and set energy type for electric.
EXCEPTION ERROR with the description on the right.
An error has occurred. Press 1234 to enter setup and reconfigure the computer.
Press YES to silence alarm. The error is displayed three times. See list of issues in section 1.14.3. Fix issue. The computer displays SYSTEM ERROR FIXED? YES/NO. Press YES. Computer displays ENTER CODE. Enter 1111 to clear error code. Pressing NO will allow the fryer to cook but the error will be redisplayed every 15 minutes. M3000 display is in wrong temperature scale (Fahrenheit or
An error has occurred.
by the error.
See section 1.14.2 on page 1-33 to change temperature scale.
Incorrect display option programmed.
Celsius).
Change the filter pad and ensure the filter pan has been removed from the fryer for a minimum of 30 seconds. Do NOT ignore CHANGE FILTER PAD prompts.
Filter error has occurred, filter pad clogged, 24 hour filter pad change prompt has occurred or change filter pad was ignored on a prior prompt.
M3000 displays CHANGE FILTER
PAD.
A. Pull filter pan out and fully reinsert into
fryer. B. Ensure the filter pan magnet is in place
A. Filter pan is not fully inserted into fryer. B. Missing filter pan magnet. C. Defective filter pan switch.
and if missing replace. C. If the filter pan magnet is fully against
INSERT pan.
the switch and computer continues to display INSERT pan, switch is possibly defective.
Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).
This in an indication of a malfunction in the temperature control circuitry, including a failure of the high-limit thermostat.
hot-hi-1.
This is displayed only during a test of the high-limit circuit and indicates that the high- limit has opened properly.
HI-LIMIT. Computer in high-limit test mode.
This display is normal when the fryer is first turned on while in the melt cycle mode. To bypass the melt cycle press and hold either #1 or #2 cook button under the LCD display until a chirp is heard. The computer displays EXIT MELT alternating with YES NO. Press the #1 YES button to exit melt. If the display continues, the fryer is not heating. M3000 display shows ERROR RM SDCRD Defective SD Card Replace card with another card.
low temp alternating with MLT-
Frypot temperature is between 180°F (82°C).
CYCL.

A. Problem with the temperature
A. This indicates a problem within the
measuring circuitry including the probe. B. Damaged computer wiring harness or
temperature measuring circuitry. Check resistance of probe, if faulty replace probe. B. Swap the computer wiring harness with
connector.
FAILURE.
one known to be good. If problem is corrected, replace the harness. MAINT FILTER (Manual Filter) won’t
Temperature too low. Ensure fryer is at setpoint before starting MAINT FILTER.
start.
Remove and discard product. Press a cook button under the display with the error to remove the error. Reset the setpoint of the vat before trying to cook product.
In non-dedicated mode, a product is dropped that has a different setpoint that the current vat temperature.
M3000 display shows REMOVE DISCARD.
Turn off the vat with the issue. The error is displayed if the fryer loses its ability to heat oil. It is also displayed when the oil temperature is above 450°F (232°C) and the high-limit thermostat has opened, halting the heating of the oil. Computer will not go into program mode or
Failed computer, failed interface board, open high-limit thermostat.
HEATING FAILURE.
Failed computer. Replace computer
some buttons do not
actuate.
This is displayed during a test of the high- limit circuit to indicate if the high-limit has failed. M3000 display shows HELP HI-2 or HIGH
HI 2 BAD. Computer in high-limit test mode.
Failed high-limit. This is displayed to indicate the high-limit has failed.
LIMIT FAILURE.
Check that all harnesses between M3000’s, MIB, AIF and ATO are secure. Ensure 24VDC is present on pins 5 & 6 of J2 on MIB board and on J4 or J5 of AIF board. Check for loose or broken pins/wires. If the problem persists, swap out computer from one bank to another and cycle power on the fryer.
software for only M3000 or MIB but not
Loose or damaged harness
all boards.
A. Ensure all cords are fully seated in the
receptacles, locked into place and that circuit breakers are not tripped. B. Check three amp fuse on front of control
A. Three phase power cord unplugged or
M3000 display shows low temp, heating indicator cycles on and
circuit breaker is tripped. B. Blown fuse C. Failed computer. D. Damaged computer wiring harness. E. Open connection in high-limit circuit.
box. C. Replace computer. D. Replace computer wiring harness. E. Check high limit circuit starting at the
off normally but fryer
does not heat.
control box connector working to the high-limit.

A filter error has occurred due to dirty or
clogged filter pad or paper, clogged filter pump, filter pump thermal overload, improperly installed filter pan components, worn or missing O-rings, cold oil or an actuator problem.
Follow the steps in the flowchart in section 1.14.5.
YES NO.
Overwrite the filter after setting by re-entering the filter after value in level two. Ensure that the down arrow is pressed after entering the value to save the setting (see section 4.13.5 on page 4-33 in the BIELA14 IO Manual). 1.14.2 M3000 Useful Codes To enter any of the following codes: Press and hold 3and 4simultaneously for TEN seconds; three chirps sound. The computer displays TECH MODE. Enter the codes below to perform the function.
Fryer filters after each
Filter after setting incorrect or software update issue.
cook cycle.
To enter level one, level two passwords: Press and hold the TEMP and INFO buttons simultaneously until level 1 or level 2 is displayed. Release the buttons and ENTER Code appears.
M3000 display shows

1.14.3 Service Required Errors A SERVICE REQUIRED error alternating with YES displays on the computer. After YES is pressed the alarm is silenced. The computer displays an error message from the list below three times with the location of the error. Then the computer displays SYSTEM ERROR FIXED? YES/NO. If yes is chosen, enter code 1111. If NO is chosen the system returns to cook mode for 15 minutes then redisplays error until issue is fixed. Pressing the MIB reset button during any filter function will generate a “SERVICE REQUIRED” error. This is a list of the service required errors and causes.
ERROR MESSAGE EXPLANATION PUMP NOT FILLING Oil not returning to vat quickly. Possible problems: dirty pad, bad or missing O-rings, tripped or defective filter pump, actuators or linkage. DRAIN VALVE NOT OPEN Drain valve failed to open; the valve’s position is unknown. DRAIN VALVE NOT CLOSED Drain valve failed to close; the valve’s position is unknown. RETURN VALVE NOT OPEN Return valve failed to open; the valve’s position is unknown. RETURN VALVE NOT CLOSED Return valve failed to close; the valve’s position is unknown. MIB BOARD Problem with CAN communications; Check for loose CAN connections between computer and MIB board. MIB board failure AIF BOARD MIB detects AIF missing; AIF board failure ATO BOARD MIB detects ATO board connection lost; ATO board failure HIGH LIMIT FAILURE High limit circuit has an issue AIF PROBE AIF RTD reading out of range ATO PROBE ATO RTD reading out of range TEMP PROBE FAILURE TEMP Probe reading out of range MIB SOFTWARE Internal MIB software error INVALID CODE LOCATION SD card removed during update MISCONFIGURED ENERGY TYPE Energy type in fryer setup is incorrect. (ie. Set proper energy type gas or electric) Press 1234 to enter setup to properly configure fryer. RTC INVALID DATE The date is invalid. Press 1234 to enter setup to properly configure fryer and set proper date.

1.14.4 Error Log Codes Refer to page 1-39, level 2 program for access to the E-log. The ten most recent errors are listed from A-J, with A being the most recent error.
Code ERROR MESSAGE EXPLANATION E01 REMOVE DISCARD (Right) A product cook is started on the right side of a split vat or in a full vat that has a different setpoint other than the current vat temperature. E02 REMOVE DISCARD (Left) A product cook is started on the right side of a split vat or in a full vat that has a different setpoint other than the current vat temperature. E03 ERROR TEMP PROBE FAILURE Temp probe reading out of range E04 HI 2 BAD High limit reading is out of range. E05 HOT HI 1 High limit temperature is past more than 410°F (210°C), or in CE countries, 395°F (202°C) E06 HEATING FAILURE A component has failed in the high limit circuit such as computer, interface board, contactor or open- high limit. E07 ERROR MIB SOFTWARE Internal MIB software error E08 ERROR ATO BOARD MIB detects ATO board connection lost; ATO board failure E09 ERROR PUMP NOT FILLING Oil not returning to vat quickly. Possible problems: dirty pad, bad or missing O-rings, tripped or defective filter pump, actuators or linkage. E10 ERROR DRAIN VALVE NOT OPEN Drain valve failed to open; the valve’s position is unknown. E11 ERROR DRAIN VALVE NOT CLOSED Drain valve failed to close; the valve’s position is unknown. E12 ERROR RETURN VALVE NOT OPEN Return valve failed to open; the valve’s position is unknown. E13 ERROR RETURN VALVE NOT CLOSED Return valve failed to close; the valve’s position is unknown. E14 ERROR AIF BOARD MIB detects AIF missing; AIF board failure E15 ERROR MIB BOARD Cooking computer detects MIB connections lost; Check software version on each computer. If versions are missing, check CAN connections between each computer; MIB board failure E16 ERROR AIF PROBE AIF RTD reading out of range E17 ERROR ATO PROBE ATO RTD reading out of range E18 Not currently used E19 M3000 CAN TX FULL Connection between computers lost E20 INVALID CODE LOCATION SD card removed during update E21 FILTER PAD PROCEDURE ERROR (Change Filter Pad)
25 hour timer has expired or dirty filter logic has activated E22 OIL IN PAN ERROR The MIB has reset the oil in pan flag. E23 CLOGGED DRAIN (Gas) Vat did not empty during filtration E24 AIF BOARD OIB FAILED (Gas) Oil is back sensor failed. E25 RECOVERY FAULT Recovery time exceeded maximum time limit. E26 RECOVERY FAULT CALL SERVICE Recovery time exceeded maximum time limit for two or more cycles. E27 LOW TEMP ALARM Oil temperature has dropped lower than 15°F (8°C) in idle mode or 45°F (25°C) in cook mode.

1.14.5 Tech Mode Tech mode allows technicians to reset all passwords set in levels one and two and change when the fryer calls for a filter pad change. The default is 25 hours.
4. Press the 9 (1) button to accept selection and clear the passwords. 5. The computer displays CLEAR PASSWORDS on the left and COMPLETE on the right. This clears any passwords set up under levels one and two. 6. Press the ubutton to toggle to FILTER PAD TIME on the left and 25 on the right. (25 hours is the default time to change the pad) 7. Press the 8 (2) button to accept changes and exit. 8. The computer displays OFF.

MESSAGE DISPLAYED
NORMAL OPERATION
RESUMES
SIXTH CONSECUTIVE FILTER ERROR
TECH ENTERS
Fryer returns to cook mode for 15
minutes.
Change filter pad and
ensure filter pan is
Fryer returns to cook mode for 4
pulled out for a minimum of 30
minutes or 15 minutes if pad change expired.
seconds.
If the computer displays SERVICE REQUIRED, the fryer can be used in most cases by answering NO when the prompt for SYSTEM ERROR FIXED? YES NO is displayed. The message repeats every 15 minutes until the issue is repaired and error cleared by a technician. To clear the error, enter 1111 after answering YES when SYSTEM ERROR FIXED? YES NO is displayed.
This chart follows the process of clearing a filtration issue. The prompt is displayed when any of the following occur: 1. a clogged filter pad, 2. a tripped or defective filter pump, 3. a leaky O-ring on the pick-up tube, 4. a failed drain valve/actuator, or 5. a failed return valve/actuator.
Call an Authorized · Repair Technician

1.14.7 M3000 Menu Summary Tree Reflected below are the major programming sections in the M3000 and the order in which submenu headings will be found under the sections in the Installation and Operation Manual. Adding New Menu Items See section 4.10.2 Storing Menu Items in Product Buttons See section 4.10.3 Draining, Refilling, and Disposing of Oil See section 4.10.4


2 Ground 3 12VAC In 12VAC 4 FV Heat Demand 5 V Relay 12VDC 6 DV Heat Demand 7 R/H B/L 12VDC 8 Analog Ground 9 L/H B/L 12VDC 10 ALARM 11 Sound Device 5VDC 12 ALARM 13 FV Probe 14 Common Probes 15 DV Probe 16
Black 2 Vat #2 3 Vat #3 4 Vat #4 5 Vat #5 6 Ground J4 Not Used
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4
1 Ground Black 2 CAN Lo Red 3 CAN Hi White 4

Updating the software takes approximately 30 minutes. The software only needs to be loaded in ONE computer and it will update all the computers and boards in the system. To update the software, follow these steps carefully:
1. Switch all computers to OFF. Press the TEMP button to check current M3000/MIB/AIF/ATO software version. 2. Remove the bezel and remove the two screws on the left side cover plate of the M3000 board. 3. With the computer folded down, insert the SD card, with the contacts facing down and the notch on the bottom right (see Figure 23 and 24), into the slot on the left side of the M3000. 4. Once inserted, UPGRADE IN PROGRESS appears on the left display and WAIT on the right. 5. The display then changes to CC UPDATING on the left and the percentage completed appears on the right. The display counts up to 100 on the right, changing to a flashing BOOT. DO NOT REMOVE THE CARD UNTIL THE DISPLAY PROMPTS TO DO SO IN STEP 8. 6. Then UPGRADE IN PROGRESS is displayed on the left display and WAIT on the right again followed by COOK HEX, mib HEX, aif HEX ending with aTO HEX displayed on the left and the percentage complete on the right. 7. The display then changes to REMOVE SD CARD on the left and 100 on the right. 8. Remove the SD card using the fingernail slot on the top of the SD card. 9. Once the SD card is removed the display changes to CYCLE POWER. 10. Cycle the control power using the hidden reset switch behind the right control box. ENSURE THE SWITCH IS HELD FOR 10 SECONDS. WAIT ANOTHER 20 SECONDS UNTIL THE MIB BOARD HAS FULLY RESET BEFORE CONTINUING. 11. An EXCEPTION MISCONFIGURED ENERGY TYPE error may appear on the left computer while a flashing BOOT is displayed on the remaining computers while the program is transferred. If this happens, enter 1234 on the left computer. The display changes to LANGUAGE on the left and ENGLISH on the right. To change the entry use the < FLTR and FLTR > buttons. To navigate to the next field, use the uINFO button. Once all parameters have been setup, press 8 (2) button to exit. SETUP COMPLETE is displayed. 12. When the update is complete the M3000 displays OFF. The MIB display will remain blank while software is loading, changing to show the vat numbers. Once the LED’s stop blinking, the MIB board will display A. 13. Cycle the control power using the hidden reset switch behind the right control box again. ENSURE THE SWITCH IS HELD FOR 10 SECONDS. WAIT ANOTHER 20 SECONDS UNTIL THE MIB BOARD HAS FULLY RESET BEFORE CONTINUING. 14. With the computer displaying OFF, VERIFY software update by pressing the TEMP button to check updated M3000/MIB/AIF/ATO version on each computer. IF ANY BOARDS DID NOT UPDATE, REPEAT THE PROCESS STARTING WITH STEP 3. 15. Press and hold the two outer filter buttons until TECH MODE is displayed. 16. Enter 1650, CLEAR PASSWORDS is displayed. 17. Press the INFO button once. FILTER PAD TIME is displayed on the left side and 25 is displayed on the right. IF ANY OTHER NUMBER OTHER THAN 25 IS DISPLAYED, ENTER 25. This only needs to be performed on one computer. 18. Press the INFO button again. 19. Press the 8 (2) button to exit. 20. Once the software has been updated and the versions are correct, replace the cover and screws covering the SD card slot. 21. Reinstall the screws attaching the computers and bezel by reversing steps 2 through 5. 22. Perform a forced auto filter cycle on each vat except the fish vat by pressing and holding one of the filter buttons. FILTER MENU is displayed changing to AUTO FILTER. 23. Press the (1 9) button. 24. FILTER NOW YES/NO is displayed. 25. Press the (1 9) button. 26. SKIM VAT is displayed changing to CONFIRM. 27. Press the (1 9) button. The auto filter cycle should start. 28. Once the filter cycle is complete, repeat on each vat in the fryer. 29. Once all vats have been successfully filtered the software update is finished.


Figure 23 Figure 24



The following diagram and charts provide ten quick system checks that can be performed using only a multimeter.


Diagnostic LED Legend CMP indicates power from 12V transformer 24 indicates power from 24V transformer HI (RH) indicates output (closed) from right latch relay HI (LH) indicates output (closed) from left latch relay HT (RH) indicates output from right heat relay HT (LH) indicates output from left heat relay AL (RH) indicates output (open) from right latch relay AL (LH) indicates output (open) from left latch relay
Meter Setting Test Pin Pin Results 12 VAC Power 50 VAC Scale 3 of J2 1 of J2 12-16 VAC 24 VAC Power 50 VAC Scale 2 of J2 Chassis 24-30 VAC *Probe Resistance (RH) R X 1000 OHMS 11 of J2 10 of J2 See Chart *Probe Resistance (LH) R X 1000 OHMS 1 of J1 2 of J1 See Chart High-Limit Continuity (RH) R X 1 OHMS 9 of J2 6 of J2 0 - OHMS High-Limit Continuity (LH) R X 1 OHMS 6 of J1 9 of J1 0 - OHMS Latch Contactor Coil (RH) R X 1 OHMS 8 of J2 Chassis 3-10 OHMS Latch Contactor Coil (LH) R X 1 OHMS 5 of J1 Chassis 3-10 OHMS Heat Contactor Coil (RH) R X 1 OHMS 7 of J2 Chassis 11-15 OHMS Heat Contactor Coil (LH) R X 1 OHMS 4 of J1 Chassis 11-15 OHMS * Disconnect 15-Pin harness from the computer before testing the probe circuit.

Probe Resistance Chart For use with fryers manufactured with Minco Thermistor probes only. F OHMS C F OHMS C F OHMS C F OHMS C F OHMS C 60 1059 16 130 1204 54 200 1350 93 270 1493 132 340 1634 171 65 1070 18 135 1216 57 205 1361 96 275 1503 135 345 1644 174 70 1080 21 140 1226 60 210 1371 99 280 1514 138 350 1654 177 75 1091 24 145 1237 63 215 1381 102 285 1524 141 355 1664 179 80 1101 27 150 1247 66 220 1391 104 290 1534 143 360 1674 182 85 1112 29 155 1258 68 225 1402 107 295 1544 146 365 1684 185 90 1122 32 160 1268 71 230 1412 110 300 1554 149 370 1694 188 95 1133 35 165 1278 74 235 1422 113 305 1564 152 375 1704 191 100 1143 38 170 1289 77 240 1432 116 310 1574 154 380 1714 193 105 1154 41 175 1299 79 245 1442 118 315 1584 157 385 1724 196 110 1164 43 180 1309 82 250 1453 121 320 1594 160 390 1734 199 115 1174 46 185 1320 85 255 1463 124 325 1604 163 395 1744 202 120 1185 49 190 1330 88 260 1473 127 330 1614 166 400 1754 204 125 1195 52 195 1340 91 265 1483 129 335 1624 168 405 1764 207






1.19.6 Contactor Box – WYE Configuration





1.19.9 Simplified BIELA14 LOV™ Gen II Series – Full Vat Wiring EXPORT WYE


1.19.10 Simplified BIELA14 LOV™ Gen II Series – Dual Vat Wiring EXPORT WYE




CHAPTER 2: PARTS LIST

PART # COMPONENT 1 809-0171 Thumbscrew, ¼ -20 X 1⅜-inch Universal Hood 809-0402 Thumbscrew, ¼ -20 X ½-inch Cap-N-Splash Hood 2 810-2793 Hanger, Wireform Basket * 809-0921 Spacer, Basket Hanger 3 803-0398 Brush, Frypot 4 823-7263 Connecting Strip, Frypot 5 106-8325 Cover, Full-Vat Frypot * 106-8329 Cover, Dual-Vat Frypot 6 803-0132 Rack, Full-Vat Basket Support 7 803-0106 Rack, Dual-Vat Basket Support 8 803-0388 Element Lift / Fryers Friend LOV™ *Not illustrated.

ITEM PART # COMPONENT 1 231-0323 Side, Standard Cabinet Left SS (use 221-0323 for Enameled Steel) 2 232-0323 Side, Standard Cabinet Right SS (use 222-0323 for Enameled Steel) 3 810-1105 Magnet, Door (vertical) (use 810-2346 for horizontal over filter pan) 4 108-0915 Door, Left or Right (Left shown – move handle to bottom for right) 5 230-4960 Handle, Eurolook Door 6 106-4067 Pin Assembly, Door * 810-0275 Spring, Door Pin * 809-0970 Retaining Ring * 230-7192 Hinge, Door Lower * 220-6097 Holder, Manual 7 810-0327 Caster without Brake 8 810-0326 Caster with Brake 9 Tilt Housing (Housing for five station fryer shown) 823-6085 Two Station, S/S (use 108-0131 for Aluminized Steel) (910-2441 Hoodstrip) 823-5700 Three Station, S/S (use 108-0132 for Aluminized Steel) (910-2440 Hoodstrip) 823-6151 Four Station, S/S (use 108-0133 for Aluminized Steel) (910-2439 Hoodstrip) 823-6243 Five Station, S/S (use 108-0138) for Aluminized Steel) (910-9447 Hoodstrip) 10 Cap-N-Splash 823-6420 Two Station 823-6421 Three Station 823-6422 Four Station 823-6887 Five Station 11 Top Cap (Top cap for five station fryer shown) 106-7835 Two Station (Also requires four 809-0078 10-32 Nutserts) 106-5979 Three Station (Also requires six 809-0078 10-32 Nutserts) 106-7576 Four Station (Also requires eight 809-0078 10-32 Nutserts) 106-7841 Five Station (Also requires ten 809-0078 10-32 Nutserts) * Not illustrated.

2.3.1 Drain Tube Sections and Associated Parts

ITEM PART# COMPONENT 1 823-6020 Drain Tube, Full-Vat Left Closed/Right End Open 2 823-6112 Drain Tube, Dual-Vat Left Closed/Right End Open 3 108-1874 Drain Tube, Dump (Use 108-1882 for French Unit) 4 108-1876 Drain Tube, Full-Vat 2 Bat. Dump Left Closed/Right End Open 5 108-1878 Drain Tube, Dual-Vat 2 Bat. Dump Left Closed/Right End Open 6 823-6019 Drain Tube, Full-Vat Left and Right Open 7 823-6021 Drain Tube, Dual-Vat Left and Right Open 8 823-6240 Drain Tube, Full-Vat 2 Bat. Left Open/Right End Closed 9 823-6242 Drain Tube, Dual-Vat 2 Bat. Left Open/Right End Closed 10 823-6202 Drain Tube, Full-Vat Left Open/Right End Closed 11 823-6114 Drain Tube, Dual-Vat Left Open/Right End Closed 12 823-6117 Drain Tube, Full-Vat Left and Right Open 13 823-6115 Drain Tube, Dual-Vat Left and Right Open 14 816-0772 Sleeve 15 809-0969 Clamp * 816-0630 Vinyl Cap * 810-3531 Valve, Check 20 PSI RTI bypass * Not illustrated.


ITEM PART # COMPONENT 1 809-0540 Nut, ½-13 2-Way Hex Lock 2 900-2936 Retainer, Nut Drain Valve 3 232-5701 Handle, Drain Valve FV or DV Right 4 231-5701 Handle, Drain Valve DV Left 5 824-2048 Mount, Electric Drain Actuator Right 6 824-2047 Mount, Electric Drain Actuator Left 7 222-5962 Bracket, Drain to Valve LOV™ Electric 8 816-0544 O-Ring, Round Drain Seal 9 823-7231 Valve, 1¼-inch Drain LOV™ Electric Right 10 823-7230 Valve, 1¼-inch Drain LOV™ Electric Left 2.3.2.2 Rotary Actuator Drain Valves

ITEM PART # COMPONENT 1 810-3755 Valve, 1¼-inch NPT Rotary Actuator

2.4.1 Component Boxes


2.4.1 Component Boxes cont.
ITEM PART # COMPONENT 1 106-5592 Box Assembly, Component 2 200-3300 Bracket, Component Box Strain Relief 3 806-9495SP Terminal Block √ 4 807-4346 Relay, 120V DPDT 20A (used in Canadian models only) √ 5 807-4482 Relay, Filter 2 Pole 30A DPDT 24VDC 6 807-0037 Terminal, ¼-inch Push-on 7 807-0121 Bushing, Heyco Plastic AB-625-500 8 807-0922 Holder, Buss Fuse HPS Screw Type 9 807-2278 Fuse, 20 Amp 10 810-2446 Plug, Button .50 Heyco Double “D” √ 11 807-4036 Switch, Power 807-3575 Plug, Carling Switch Hole (used on some models without a switch) 12 807-1947 Plug, Button .875 Dome 13 807-1321 Holder, AGC Panel Mount ¼” Fuse (Some models use item 10 here.) 14 807-1597 Fuse, 3 AMP Slow-Blow 15 810-2445 Plug, Button .625 Heyco Double “D” 16 106-5750 Harness Assembly, RE FV Control 106-5751 Harness Assembly, RE DV Control √ 17 807-0855 Transformer, 100-120V/12V 20VA √ 18 807-0800 Transformer, 100-120V/24V 50VA Filter (Used in FV component boxes) √ 807-4933 Transformer, 120/208/240V/24V 75VA Filter (Used in DV component boxes) √ 19 807-2181 Transformer, 100-120V /24V 62VA Filter √ 20 807-2191 Transformer, 208-240V/12V 30VA √ 21 807-0979 Transformer, 208-240V/12V 43VA √ 22 807-2180 Transformer, 100-120V 50VA Filter 23 809-0349 Spacer, 4mm X 6mm Aluminum 24 Interface Board √ 826-2260 Standard Full or Dual Vat Interface Board (includes sound harness) * 807-4403 Speaker, 4-Watt SMT 25 220-4723 Guard, Finger w/ switch opening 26 807-4678 Switch, Momentary Flush JIB Reset 27 230-5038 Guard, RE Box Switch 28 816-0217 Paper, Insulating Terminal Block 29 810-0045 Bushing, .875 Diameter 11/16” 30 200-6654 Brace, Component Box √ 31 807-4346 Relay, DPDT 20A 120V (used for control power reset in right hand boxes only in domestic and Canadian units) 807-4770 Relay, DPDT 20A 240V (used for control power reset in right hand boxes only in international units; some international units have one located in each control box) 32 807-2659 Switch, Momentary (used to reset control power; located in box over JIB only.) * 826-2249 RE Hood/Ansul Interlock Kit (includes terminal block, wires and connectors) * Not illustrated. √ Recommended parts.



2.4.2.1 Left and Right Contactor Box Configurations cont. NOTES: Left and right contactor box assemblies are mirror images of one another. With the exception of the box itself, all components of a left-hand assembly are the same as those in the corresponding right-hand assembly and vice versa except for the hood relay which occurs in the right or large box only. The configurations illustrated show all possible components, but a particular configuration may not have all the components shown.
ITEM PART # COMPONENT 1 106-8658 Box Assembly, Left Contactor 2 106-8660 Box Assembly, Right Contactor 3 221-0482 Cover, Left Hand Contactor Box 4 222-0482 Cover, Right Hand Contactor Box 9 807-0070 Terminal, Ground Lug √ 5 807-2284 Contactor, 24V 50 Amp Mechanical (Heat) √ 6 810-1202 Contactor, 24V 40 Amp Mechanical (Latch) 7 807-1683 Relay, Hood 12VDC 8 807-0922 Holder, Bus Fuse 9 807-2278 Fuse, 20 Amp 10 807-0064 Transformer, 480V/120V 150VA * 221-0610 Bracket, Left Hand Contactor Box Mounting * 222-0610 Bracket, Right Hand Contactor Box Mounting * 807-4316 McDonald’s Cordset, 120V 5-Wire * 807-4317 McDonald’s Cordset, Europe 3-Wire Single Phase * 807-0012 Relay, Tilt Switch 18 Amp 1/3 HP 24 V Coil * Not illustrated. √ Recommended parts.



2.4.3.1 Element Assemblies and Hardware cont.
ITEM PART # COMPONENT 1 Element 826-2198 200V 7.0 kW (220V 8.5kW used in some export 3-phase 4-wire WYE units) √ 826-2192 208V 17.0 kW 826-2200 220V 17.0 kW (240V 8.5kW used in some export 3-phase 4-wire WYE units) 826-2193 230V 17.0 kW 826-2199 230V/400V 7.0/8.5 kW (used in some export 3-phase 4-wire WYE units) 826-2194 240V 17.0 kW 826-2196 480V 17.0 kW √ 2 826-2212 Probe, Temperature RE – includes tie wraps and grommet. 3 816-0681 Grommet, Probe 4 816-0480 Plug, .375-inch Dome 5 816-0688 Gasket, Element 6 809-1003 Screw, 10-32 X ⅜-inch Hex Head SS * 809-0766 Nut, 10-32 Keps Hex Head SS * 230-4028 Wrench, Element Tube Nut Spanner 7 230-3714 Bracket, Temperature Probe 7.0kW
230-0784 Bracket, Temperature Probe 8.5kW (used in some export 3-phase 4-wire WYE units) 8 220-0464 Bracket, Lower Spring 9 910-2042 Clamp, Element (Short) 10 230-0781 Clamp, Element (Long) 11 230-4902 Support, Full-Vat Element Rear 12 230-4101 Support, Full-Vat Element Front 13 809-0567 Tie-Wrap, Metal 14 230-4903 Support, Dual-Vat Element Bottom Rear 15 230-4103 Support, Dual-Vat Element Bottom Front 16 810-3030 Spring, Element Lift Left 810-3131 Spring, Element Lift Right 17 220-0733 Bracket, Lower Spring Mating * Not illustrated. √ Recommended parts.

FULL-VAT ELEMENT ASSEMBLY
DUAL-VAT ELEMENT ASSEMBLY

2.4.3.2 Element Tube Assemblies contd.
ITEM PART # COMPONENT 1 108-0297SP Tube Assembly RE Element, Full-Vat 2 108-0298SP Tube Assembly RE Element, Dual-Vat 3 810-3246 Bushing and Tube Assembly, Dual-Vat 4 108-0315 Bracket Assembly, LH Element Tube Support 5 108-0316 Bracket Assembly, RH Element Tube Support 6 220-0122 Plate, Element Tube Support Inner 7 220-0123 Plate, Element Tube Support Outer 8 106-7651 Bracket Assembly, LH Upper Spring (use 106-6569 for 17kW) 9 106-7652 Bracket Assembly, RH Upper Spring (use 106-6570 for 17kW) 10 810-2992 Tube, Full Vat Element Mounting 11 810-2993 Bushing, Tube End Teflon * 826-2598 Kit, Tilt Switch * 807-4742 Switch, Long Lever High Temp * Not illustrated. 2.4.4 Computers

ITEM PART # COMPONENT Replacement Computer √ 108-1295 Non-CE Domestic M3000 (For use in US, Canada, Mexico and all other non-CE countries) √ 108-2970 CE M3000 (For use in European CE countries) * 807-4403 M3000 Speaker SMT * Not illustrated. √ Recommended parts.

ITEM PART # COMPONENT 106-5980SP Contactor Box Harness Assembly Dual Vat 1 Standard (See wiring diagrams on pages 1-41 thru 1-43.) 2.4.5.2 Contactor Box Wiring Assemblies – 12-Pin Full-Vat C-1
BLUE 74C
ORANGE 76C
ORANGE 71C
ITEM PART # COMPONENT 106-6031SP Contactor Box Harness Assembly Full Vat 1 Standard (See wiring diagrams on pages 1-41 thru 1-43.)

ITEM PART # COMPONENT 1 106-8744 14/17 kW Mechanical Contactor 2.4.5.4 Contactor Box Wiring Assembly – 9-Pin (Right Element)
ITEM PART # COMPONENT 1 106-8745 14/17 kW Mechanical Contactor



ITEM PART # COMPONENT 1 106-5750SP Full Vat Control Harness J4 to J2 (Standard) 2 106-5751SP Dual Vat Control Harness J4 to J1 and J2 (Standard) 3 108-0490 Filter Pump C2 to Component Box Wiring Harness 2.4.5.7 Interface Board to Controller Wiring Harness – 15-Pin


ITEM PART # COMPONENT * 807-4546 Computer Communication (used from Computer to Computer) * 807-4547 AIF Communication/Power (used from MIB to AIF and AIF to AIF)
* 807-4649 MIB Power/Blue LED/Pan Sw (used from Transformer and Fltr Rly to MIB to Blue LED and Pan Sw) * 807-4655 FV/DV Harness RTD Medium (used from RTD to ATO Board) * 826-2569 FV/DV ATO/RTD Probe Kit * 807-4553 ATO Power (used from Transformer to ATO Board)
* 807-4671 ATO Pump and JIB (used from ATO Board to Top-off Pump and JIB Reset Switch)
* 807-4772 ATO Pump and JIB (used from ATO Board to Top-off Pump and JIB Reset Switch) 4-5 Battery only * 807-4555 ATO Yellow LED (used from ATO Board to Yellow LED)
* 807-4722 ATO Yellow LED (used from ATO Board to Yellow LED) 4-5 Battery only
* 807-4573 Computer Locator Wire (used from Computer to Interface Board) See wiring diagram 805-1734 for locator pin positions.
* 807-4552 Communications Terminator (used on Computer pin J6 and ATO board pin J10 to terminate network) 807-4657 Jumper (used on 4 and 5 battery ATO board plug J5 pin 7 and 8) * 106-9256SP Long Top-off Power (used between Component Box to ATO Box) * 807-4760 Harness, LOV™ RTI-MIB connector √ * 807-4660PK SMT Pin Service Repair Kit √ * 230-2345 SMT Pin Extractor * Not illustrated. See page 1-14, 1-18, 1-27 and 1-36 for Pin Positions. √ Recommended parts.



2.5.1 Filtration Components cont.
ITEM PART # COMPONENT 1 823-7181 Lid, Multi-Vat Fryers, Standard Size Filter Pan 823-6684 Lid, Multi-Vat Fryers, Standard Size Filter Pan (France Only) 823-7187 Lid, Two-Vat Fryer, Half Size Filter Pan 823-6162 Lid, Two-Vat Fryer, Half Size Filter Pan (France Only) 1a 823-7186 Guard, Pan Splash Lid 2 810-3276 Crumb Tray, Standard Size Filter Pan 3, 4 and 5 Vat 810-3288 Crumb Tray, Two-Vat Fryer, Half Size Filter Pan 3 810-3268 Hold-Down Ring for Pad 16.56 x 22.32, Standard Size Pan 3, 4, and 5 Vat 810-3289 Hold-Down Ring for Pad 11.20 x 19.10, Two-Vat Fryer, Half Size Filter Pan 4 200-2240 SanaGrid Filter Screen, Standard Size Filter Pan 220-2901 SanaGrid Filter Screen, Two-Vat Fryer, Half Size Filter Pan 5 106-8677SP Pan, One-Piece Filter LOV™ Standard Size 106-9148 Pan, One-Piece Filter LOV™ Standard Size (France Only) 106-8211SP Pan, Two-Vat Fryer, LOV™ Half Size 106-8435 Pan, Two-Vat Fryer, LOV™ Half Size (France Only) 6 823-6715 Suction Tube Standard LOV™ 823-6164 Suction Tube Standard LOV™ (France Only) 823-6399 Suction Tube Two Vat LOV™ 7 810-3007 Magnet, Pull Ring 8 106-9251SP Assembly, Filter Pan Switch Three Vat or more (106-5876SP Sensor only) 106-8080SP Assembly, Filter Pan Switch Two Vat (106-5876SP Sensor only) * 106-5876SP Sensor, Magnet 9 230-3936 Rail, Filter Pan Retaining Standard 10 220-3748 Support, Left Filter Pan 220-3275 Support, Left Filter Pan Two Vat LOV™ 11 220-3749 Support, Right Filter Pan 106-8487 Support, Right Filter Pan Two Vat LOV™ 12 Motor and Gasket Kit 826-1785 100V 50/60 Hz √ 826-1712 115V 50/60 Hz √ 826-1756 208V 50/60 Hz 826-1270 220-240V 50/60 Hz 826-1755 250V 50/60 Hz 13 826-2789 Pump, Viking 8 GPM Kit (includes gasket 816-0093) * 807-11973 Viking Pump Seal Kit * 809-1020 Cap Screw, 5/16-inch-18 5.50” NC Hex (Connects pump to motor.) 14 813-0165 Elbow, ST ½-inch x ½-inch NPT 90° BM 15 810-1668 Adapter, ⅝-inch to ½-inch NPT Male 16 810-1067 Flexline, 8.5-inch Oil Return 17 810-1057 Flexline, 13-inch Oil Return 18 810-0667 Check Valve ½” NPT 19 810-3738 Adaptor, Check Valve Close Nipple 20 813-0031 Bushing, ¾” NPT x ½” BM 21 813-0062 Elbow, ½-inch x ½-inch 90° BM √ * 826-1392 O-Ring (Pkg. of 5; used with Item 5) * 813-0568 Plug, ⅛-inch Socket Head Pipe (used with Item 5; two required) * 807-1105 Heater Strip Assembly, 100-120V 25W 18” * 807-1098 Heater Strip Assembly, 208-250V 25W 18” * Not illustrated. √ Recommended parts.

106-8231SP LOV™ Panel Assembly
ITEM PART # COMPONENT 1 106-8106SP Light, Blue 24VDC LED Flush 2 106-8105SP Light, Yellow/Orange 24VDC LED Flush 3 230-4271 Plate, Control Frame LOV™ 2.5.2.2 Manual Interface Board Assembly
108-1298 Manual Interface Board Assembly
ITEM PART # COMPONENT 108-1298 Assembly, MIB 1 220-6288 Cover, MIB √ 2 108-2156 Assembly, MIB Computer w/ Frame 807-4481 Overlay 3 220-5793 Assembly Back, Box MIB √ Recommended parts.

108-1305 AIF Board Assembly
ITEM PART # COMPONENT 108-1305 Assembly, AIF 1 824-1988 Cover, AIF Board 2 816-0814 Gasket, AIF Board 3 816-0815 Gasket, Computer Board √ 4 108-1304 Board, AIF 5 816-0820 Seal, AIF Board 6 108-0097 Panel Assembly, AIF Box √ Recommended parts. 2.5.2.4 LOV PCB/Computer Board Matrix
108-2156 Assembly, MIB PCB w/ metal work 108-1305 Assembly, AIF Board w/ metal frame 108-1304 Board, AIF Board PCB w/ software 108-1279 Board, ATO PCB w/ software 108-1295 M3000 Non-CE Domestic (For use in US, Canada, Mexico and all other non-CE countries) 108-1283 M3000 CE (For use in European CE countries)

2.6 Frypot Assemblies and Associated Parts 2.6.1 Frypots with Linear Actuators
See Page 2-5 for Drain Valve Assemblies.
See Page 2-24 for Return Valve Assemblies.
ITEM PART # COMPONENT 1 823-7436 Frypot, Full-Vat LOV™ 2 823-7437 Frypot, Dual-Vat LOV™ √ 3 Thermostat Assembly, High-Limit Long Standard
826-2454 Non-CE Full Vat 425°F (218°C) (17kW FV and 14kW FV) (Color Coded Black 806-7543)
826-2456 Non-CE Dual Vat 435°F (224°C) (22kW, 17kW DV and 14 kW DV) (Color Coded Red 806-8035)
826-2455 CE Full and Dual Vat 415°F (213°C) (14kW and 17kW CE) (Color-Coded Yellow 806-8132) √ 4 826-2706 Probe, Temperature and Fitting Kit AIF/RTD 5 810-1067 Flexline, ⅝” OD x 8.50” Long 6 810-1668 Adaptor, Male ⅝” OD x ½” √ 7 826-2587 Actuator, Linear AIF 24VDC Kit includes 810-1776 8 809-1012 Pin, Clevis, ¼” x 1¼” (Drain and return valves) 9 809-1035 Pin, Clevis, ¼” x 2¼” (center pin drain actuator) 10 809-1036 Pin, Clevis, ¼” x 2” (center pin return actuator) 11 810-1776 Clip, Toaster Ring 12 108-0698 Valve, Drain Assy. LOV™ FV or DV Right as viewed from front of frypot. 13 108-0697 Valve, Drain Assy LOV™ DV Left as viewed from front of frypot. 14 108-0700 Valve, Return Assy LOV™ FV or DV Right as viewed from front of frypot. 15 108-0699 Valve, Return Assy LOV™ DV Left as viewed from front of frypot. 16 813-0022 Nipple, ½” x Close NPT BM 17 813-0165 Elbow, St. ½” x ½” NPT 90° 18 220-5960 Strap, Elec LOV™ Actuator √ Recommended parts.

2.6.2 Frypots with Rotary Actuators
ITEM PART # COMPONENT 1 823-7672 Frypot, Full-Vat LOV™ 2 823-7673 Frypot, Dual-Vat LOV™ (use 823-7745 for Hybrid Fish Vat) √ 3 Thermostat Assembly, High-Limit Long Standard
826-2454 Non-CE Full Vat 425°F (218°C) (17kW FV and 14kW FV) (Color Coded Black 806-7543)
826-2456 Non-CE Dual Vat 435°F (224°C) (22kW, 17kW DV and 14 kW DV) (Color Coded Red 806-8035)
826-2455 CE Full and Dual Vat 415°F (213°C) (14kW and 17kW CE) (Color-Coded Yellow 806-8132) √ 4 826-2706 Probe, Temperature and Fitting Kit AIF/RTD 5 810-1067 Flexline, ⅝” OD x 8.50” Long 6 810-1668 Adaptor, Male ⅝” OD x ½” √ 7 807-4961 Actuator, Rotary 24VDC (#1) √ 8 807-4962 Actuator, Rotary 24VDC (#2) √ 9 810-3755 Valve, 1¼ Drain Rotary Actuator LOV™ √ 10 810-3754 Valve, ½ NPT Return Rotary Actuator LOV™ 11 813-0022 Nipple, ½” x Close NPT BM 12 813-0062 Elbow, ½” Blk 90° 13 220-7386 Strap, Round Drain Elec LOV √ Recommended parts.


ITEM PART # COMPONENT 1 810-3015 Manifold, Two-Station Fryer 2 810-3016 Manifold, Three-Station Fryer 3 810-3017 Manifold, Four-Station Fryer 4 810-3018 Manifold, Five-Station Fryer * 813-0907 Cap, 15/16-inch Valve * Not illustrated. 2.8 Return Valves and Associated Parts 2.8.1 Return Valves and Associated Parts (Linear Actuators)


2.8.1 Return Valves and Associated Parts (Linear Actuators) cont.

ITEM PART # COMPONENT 1 232-5702 Handle, Return Valve with Locator FV or DV Right 2 231-5702 Handle, Return Valve with Locator DV Left 3 900-2935 Retainer, Nut Oil Return Valve 4 810-2201 Valve, ½-inch Ball 5 823-7233 Mount, Return Actuator Right 6 823-7232 Mount, Return Actuator Left 7 230-5963 Brace, Return Actuator Bracket 2.8.2 Return Valve (Rotary Actuators)

ITEM PART # COMPONENT 1 810-3754 Valve, ½-inch NPT Rotary Actuator

ITEM PART # COMPONENT 1 220-7991 Basket, JIB LOV™ 2.9.2 JIB Cap and Pick Up Assembly

ITEM PART # COMPONENT 108-2005 Cap, JIB Assembly (use 108-2047 for BIB) 1 108-2001 Cap, JIB (use108-2002 for Intl. BIB) 2 810-3823 Hose, JIB

2.9.2 JIB Cap and Pick Up Assembly cont.
ITEM PART # COMPONENT 3 823-7738 Inlet, Oil Reservoir Tube 4 816-0870 Clamp 2.9.3 Automatic Top Off Board Assembly
108-0507 208-240V Assy 108-0506SP 120V Assy
ITEM PART # COMPONENT 1 108-0653 Box, Assembly Auto Top Off Board 2 220-5679 Cover, Top Off Board Box √ 3 108-1279 PCB Board, Automatic Top Off
* 108-1302 PCB Board, LON Works 120V (Must be pre-programmed before shipping)
* 108-1303 PCB Board, LON Works 230-240-250V (Must be pre-programmed before shipping) √ 4 807-2181 Transformer, 100-120V/24V 62VA √ 5 807-0855 Transformer, 120V 50/60-12V 20VA √ 6 807-2180 Transformer, 208-240V/24V 50VA √ 7 807-2191 Transformer, 208/230/240 -12V 30VA 8 807-1321 Holder, Fuse AGC Panel Mount ¼” √ * 807-1597 Fuse, 3A Slow-Blow √ 9 807-0012 Relay, 18AMP 1/3 HP 24V Coil (Top off pump) * Not illustrated. √ Recommended parts. NOTE: Top off boxes for vats 4 and 5 have either item 4 or item 6, both have item 3.

Domestic Units
Item 2 connects to a check valve before going into the oil return manifold.
JIB hose connects here.
JIB hose connects here.
ITEM PART # COMPONENT √ 1 108-0639 Pump, Shurflo 24VAC 2 810-3265 Flexline, ½” OD x 24-inch (Out to oil return manifold) 810-3591 Flexline, ½” OD x 8-inch (Out to oil return manifold two battery only) * 810-0667 Check valve, ½ NPT 1 PSI 3 810-1069 Flexline, ⅝” OD x 29.5-inch (In from RTI fresh oil solenoid) Domestic units only 4 810-3666 Fitting, Shurflow Pump 5 816-0782 O-Ring, Viton #111 6 813-0940 Elbow, ¼” NPT x ⅜ Flare 7 810-3770 Fitting, ¼” NPT Male Barb 8 813-0543 Elbow, ¼” NPT BM 9 813-0838 Nipple, ¼” NPT BM Close 10 813-0530 Tee, Reducing ½” x ¼” x ½” 11 813-0304 Bushing, ½” x ¼” BM Flush 12 813-0022 Nipple, ½” x Close NPY BM 13 813-0345 Elbow, ½” BM 45° 14 810-1668 Adaptor, Male ⅝” OD x ½” 15 812-2083 Hose LOV Fryer JIB (Cut and attach to item 7 with a ty wrap) * 811-1166 Hose, Silicone Braided 18” (sold by the foot) * Not illustrated. √ Recommended parts.

Item 2 connects to a check valve before going into the oil return manifold. JIB hose connects here.
2 1 13 7
Item 3 on this page and Item 8 on the following page are the same part.
HERE 5
ITEM PART # COMPONENT 108-3041 Kit, Pump BIELA Topoff Service Kit √ 1 108-0639 Pump, Shurflo 24VAC 2 810-3265 Flexline, ½” OD x 24-inch (Out to oil return manifold) 810-3591 Flexline, ½” OD x 8-inch (Out to oil return manifold two battery only) * 810-0667 Check valve, ½ NPT 1 PSI 3 810-1069 Flexline, ⅝” OD x 29.5-inch (In from RTI fresh oil solenoid) Domesti units only 4 810-3666 Fitting, Shurflow Pump 5 816-0782 O-Ring, Viton #111 6 813-0940 Elbow, ¼” NPT x ⅜ Flare 7 813-0062 Elbow, ½” BLK 90° NPT BM 8 813-0087 Nipple, ½” x 1.50-inch 9 823-8063 JIB Connection Topoff Welded Assy. 10 813-0165 Elbow, Street ½” x ½” NPT 90° BM 11 813-0247 Nipple, ½” x 3.50-inch NPT BM 12 108-2054 Fitting Assy Shurflow 13 810-1668 Adaptor, Male ⅝” OD x ½” * 813-0907 Cap 15/16” * Not illustrated. √ Recommended parts.
11 7 12



2.10.1 RTI Manifold and Accessories cont.
ITEM PART # COMPONENT √ 1 106-6830 Solenoid Assembly 2 108-0446 Valve, RTI Waste Assembly (see page 2-32 for parts) 3 810-1668 Adaptor, Male ⅝” OD x ½” 4 220-5658 Cover, RTI Dust Plug 5 807-4760 Harness, RTI – MIB connection 6 810-1057 Flexline, ⅝” OD x 13-inch long 7 810-1668 Adaptor, Male ⅝” OD x ½” 8 810-1069 Flexline, ⅝” OD x 29.50-inch long 9 813-0555 Reducer, Bell Fitting, ½” to ¼” NPT BM 10 810-3531 Valve, Check 20 PSI RTI bypass 11 810-3583 Valve, Check ½” NPT 4 PSI RTI Manifold 12 810-3596 Manifold, RTI 13 813-0003 Tee, ½” x ½” x ½” BM 14 810-3738 Adaptor, Check Valve Close Nipple 15 813-0062 Elbow, ½” Blk 90° 16 813-0093 Nipple, ½” x 4-inch 17 813-0062 Elbow, ½” BM 90° 18 813-0261 Nipple, ½” x 5-inch NPT 19 813-0304 Bushing, ½” x ¼” 20 813-0345 Elbow, ½ Blk 45° 21 813-0336 Plug, ½” NPT Square Head 22 813-0838 Nipple, ¼” NPT 23 220-5656 Brace, RTI Handle 24 220-5657 Cover, RTI Handle 25 823-7142 Handle, RTI Waste Pull 26 810-3587 Lock and Key, RTI Waste Handle 27 809-0601 Clip, Clevis Left Rod End √ Recommended parts.


ITEM PART # COMPONENT 108-0446 Valve, RTI Dispose Waste 1 108-0445 Bracket, RTI Waste Valve 2 220-5615 Handle, RTI Waste Valve 3 807-4936 Microswitch, Gold Sealed 4 810-0278 Valve, ½” Ball 5 900-2935 Retainer, Nut Return Valve 6 901-2348 Cover, DV Safety Switch 7 902-2348 Cover, DV Safety Switch 2.10.3 RTI Test Box

ITEM PART # COMPONENT √ 108-0716 Box, LOV™ RTI Test √ Recommended parts.

ITEM PART # COMPONENT Power Cords * 807-0154 100/120V–15A 3-wire, w/grounded plug * 807-4317 100/208/240V-16A 3-Wire with Plug LOV CE * 807-1685 100/208/240V–18A 3-wire, w/o plug * 807-4316 120V 5-wire, w/grounded plug LOV * 807-3817 208/240V 3-Phase 4-wire w/grounded plug
* 807-5105 208/240V 3-Phase 4-wire w/grounded plug 105” CE 4 battery or larger Connectors and Tools 1 807-1068 2-Pin Female 2 807-0158 6-Pin Female 3 807-0156 9-Pin Female 5 807-0159 12-Pin Female 5 807-0875 15-Pin Female 6 807-1067 2-Pin Male 7 807-0157 6-Pin Male 8 807-0155 9-Pin Male 9 807-0160 12-Pin Male 10 807-0804 15-Pin Male 11 826-1341 Terminal, Female Split Pin (Pkg of 25) 12 826-1342 Terminal, Male Split Pin (Pkg of 25) 13 807-2518 Plug, Mate-N-Lock (Dummy Pin) 14 807-0928 Extract Tool Pin Pusher 15 806-4855 Pin Pusher Screwdriver Assembly 16 230-2345 SMT Pin Extractor * 807-4660PK SMT Pin Service Repair Kit * Not illustrated.

ITEM PART # COMPONENT * 809-0429 Bolt, ¼-inch – 20 x 2.00-inch Hex Head ZP Tap * 809-0131 Bolt, ¼-inch -20 x ¾-inch Hex * 809-1020 Cap Screw, 5/16-inch-18 5.50” NC Hex (Connects pump to motor.) * 809-0448 Clip, Tinnerman * 826-1366 Nut, 4-40 Keps Hex (Pkg. of 25) (809-0237) * 826-1358 Nut, 6-32 Keps Hex (Pkg. of 25) (809-0049) * 809-0247 Nut, 8-32 Keps Hex * 826-1376 Nut, 10-32 Keps Hex (Pkg. of 10) (809-0256) * 809-0766 Nut, 10-32 Keps Hex SS * 809-0581 Nut, ½ NPT Locking * 809-0020 Nut Cap 10-24 NP * 826-1372 Nut Grip ¼-inch ¼-20 Hex NP (Pkg. of 10) (809-0059) * 809-0417 Nut Flange ¼-inch ¼-20 Serr * 809-0535 Nut, "T" ¼-inch-20 x 7/16 SS * 809-0495 Nut, ¼-inch – 20 Press * 809-0540 Nut, Lock ½-inch-13 Hex 2-Way ZP * 826-1359 Screw, 4-40 x ¾-inch Slotted Round Head (Pkg. of 25) (809-0354) * 826-1365 Screw, 6-32 x ⅜-inch Slot Head (Pkg. of 25) (809-0095) * 809-0357 Screw, 6 x ⅜-inch Phillips Head NP * 809-0359 Screw, 8 x ¼-inch Hex Washer Head * 809-0360 Screw, 8 x ⅜-inch Hex Washer Slot Head * 826-1371 Screw, 8 x ½-inch Hex Head ZP (Pkg. of 25) (809-0361) * 809-0364 Screw, 8 x ⅝-inch Hex Washer Head ZP * 809-0518 Screw, 8-32 x ⅜-inch Hex Washer Slotted Head SS * 809-0104 Screw, 8-32 x ½-inch Slotted Head ZP * 826-1363 Screw, 8-32 x ½-inch NP (Pkg. of 25) (809-0103) * 826-1360 Screw, 10-24 x 5/16-inch Round Slot Head ZP (Pkg. of 25) (809-0024) * 826-1330 Screw, 10-32 x ⅜-inch Slot Head SS (Pkg. of 25) (809-0117) * 809-1003 Screw, 10-32 x ⅜-inch Hex Trim Head SS * 809-0270 Screw, 10-32 x ½-inch Phillips Head ZP * 826-1375 Screw, 10-32 x ¾-inch Hex Trim Head SS (Pkg. of 5) (809-0401) * 809-1000 Screw, 10-32 x 1¼-inch Hex Sck C/S * 826-1374 Screw, 10 x ½-inch Hex Head (Pkg. of 25) (809-0412) * 809-0266 Screw, 10 x ½-inch Phillips Head ZP * 809-0434 Screw, 10 x ⅜-inch Hex Washer Head NP * 809-0123 Screw, 10 x ¾-inch Slot Head * 826-1389 Screw, 1/4-20 x ¾-inch Hex Head ZP (Pkg. of 10) (809-0131) * 809-0582 Washer ½ NPT Locking * 809-0184 Washer, #10 LK ZP * 809-0190 Washer, .625 X .275 X 40 Flat SS * 809-0191 Washer, Lock ¼ Spring ZP * 809-0193 Washer, Flat ¼ Nylon * 809-0194 Washer, Flat 5/16 ZP




Frymaster, L.L.C., 8700 Line Avenue, Shreveport, Louisiana 71106
TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 (Tech Support) 1-318-219-7135
819-6446 MAY 2011
1-800-551-8633
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| J10 | The ATO fuse on the right side of the | p.26 |
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Frypot tops off cold. | Incorrect setpoint | Ensure setpoint is correct. | p.20 |
| No power to ATO board | A. J5 connection unplugged B. Fuse blown C. Transformer malfunction | A. Check to ensure J5 on front of ATO board is fully locked into connector. B. Ensure fuse below right control box is not blown and fuse on the right side of ATO box is not blown. C. Check that proper voltage is present at transformer. See table in section 1.10.2. | p.20 |
| The yellow JIB low light won’t illuminate. | A. Loose wire connection B. Power in the component box is not present. C. Failed transformer. | A. Ensure the yellow LED is securely attached to plug J6 on the ATO board. B. Ensure power is present in the component box. C. If power is present in component box, check the transformer for correct voltage. | p.20 |
| One vat tops off but other vats fail to top off. | A. Loose wire connection. B. Actuator issue | A. Ensure all wiring harnesses are securely connected to ATO board and solenoids. B. Check return actuator to ensure actuator is functional. | p.20 |
| Incorrect vat tops off. | A. Wired incorrectly. B. Flexlines connected to wrong vat. | A. Check wiring. B. Switch flexlines to correct vat. | p.20 |
| Frypots won’t top off. | A. Empty JIB. B. Probe temperature lower than setpoint. C. Oil is too cold. D. Bad Connection E. ATO board power loss F. Failed transformer/harness G. ATO pump failed H. Failed ATO board. I. ATO lines/pump plugged | A. Ensure JIB has oil. B. Check to see that fryer is heating. Fryer temperature must be at setpoint. Check probe resistance. If probe is bad, replace the probe. C. Ensure that the oil in the JIB is above 70°F (21°C). D. With the computer OFF, press TEMP button and ensure the ATO software version appears. If not, the connection between the AIF and the ATO board may be bad. Ensure the 6-pin CAN connectors are tight between AIF (J4 and J5) and ATO (J10) boards. E. Power to the ATO board has been cut off. Restore power to the board and clear any service required errors. F. Ensure transformer in ATO box is functioning properly. Check power from transformer to ATO board. Ensure all harnesses are plugged securely into place. G. Ensure pump is operational. Check voltage to pump. Replace the pump if defective. H. Check for proper voltages using the pin position chart found on page 1-15. If ATO found defective, replace ATO board and clear any errors. I. Clear the lines/pump. | p.21 |
| One vat doesn’t top off. | A. Filter error exists. B. Actuator, pump, loose connection, RTD or ATO issue. | A. Clear filter error properly. When change filter pad YES/NO is displayed, do NOT press any button until the pan has been removed for at least thirty seconds. After thirty seconds have elapsed, the computer returns to OFF or last display. B. Check actuator, ATO pump, wire connections, RTD and ATO board. | p.21 |
| M3000 displays SERVICE REQUIRED – ATO BOARD | A. Loose or bad fuse B. Bad Connection C. ATO Board power loss | A. Ensure fuse on right side of ATO box is secure and good. If the computer above the ATO box is missing power check the fuse below the component box. B. With the computer OFF, press TEMP button and ensure the ATO software version appears. If not, the connection between the AIF and the ATO board may be bad. Ensure the 6-pin CAN connectors are tight between AIF (J4 and J5) and ATO (J9 or J10) boards. C. Power to the ATO board has been cut off. Ensure there is correct voltage to the ATO transformer. Restore power to the board and clear any service required errors. | p.21 |
| Auto filtration won’t start. | A. Filter pan out of position. B. Oil level too low. C. Ensure MIB board is not in manual mode. D. Ensure MIB cover is not damaged and pressing against buttons. E. Filter relay has failed. F. AIF disable is set to YES, blue light doesn’t light. G. Filter motor thermal switch is tripped. H. AIF clock enabled | A. Ensure filter pan is fully inserted into fryer. If the MIB board displays a “P” the pan is not fully engaged into the pan switch. B. Ensure the oil level is above the top oil level sensor. C. Ensure MIB board is in “A” automatic mode. D. Remove and replace cover and see if filtration will start. E. Replace filter relay with part number 807- 4482 24VDC relay. F. Set AIF disable in Level 1 to NO. G. Press filter motor thermal switch. H. Ensure AIF clock is set to disabled. | p.25 |
| MIB display shows something other than an “A” or vat number. | An error has occurred and displayed character indicates error. | See MIB display diagnostics on page 1-21 for explanation. | p.25 |
| No power present at the MIB board | Transformer has failed in left component box. | Check output on the left transformer in left component box; should read 24VAC. If not replace transformer. | p.25 |
| MIB will not clear error. | Error remains in non-volatile memory. | Press and hold reset button in top right corner of MIB board for five seconds. The drain, return and manual/auto LEDS will illuminate and the MIB will reset and clear any remaining errors from memory. Allow 60 seconds to reset. If an error still exists, then another issue exists. | p.25 |
| MIB indicates incorrect number of vats. | A. Network is not terminated correctly. B. Wiring harnesses are loose or damaged. C. An AIF board issue. D. Locator pin issue. | A. Ensure the CAN bus system is terminated at BOTH ENDS (on the M3000 connector J6 and on the ATO board connector J9) with a resistor equipped 6-pin connector. B. Unplug and reseat all wiring harnesses in CAN system. Resistance between pins 2 and 3 on the CAN network connectors should be 120 ohms. C. Check software version numbers on all M3000 computers and ensure all are display an AIF version. If an AIF version is missing, the AIF board may be missing power or bad. Check pins 5 and on J4 and J5 of the affected AIF board for proper voltage. D. The locator pin in J2 of the AIF board is either loose or in the incorrect position. See the charts on page 1-55 of this manual for proper pin position. | p.25 |
| MIB board alternating “E” and “vat number and side”. | Network error on the CAN bus communication. | A. Ensure the CAN bus system is terminated at BOTH ENDS (on the M3000 connector J6 and on the ATO board connector J10) with a resistor equipped 6-pin connector. B. With the computer OFF, press TEMP button and ensure the AIF version appears. If not, the 24V to the AIF boards may be missing. Ensure all 6-pin CAN connectors are tight between the M3000 (J6 and J7), MIB (J1 and J2), AIF (J4 and J5) and ATO (J10) boards. C. With the computer OFF, press TEMP button and ensure the ATO version appears. If not, check the CAN wire harness between the AIF board J4 or J5 and the ATO board J9 or J10. The ATO fuse on the right side of the ATO box may be loose or blown; the 110V to the ATO transformer may be missing or the transformer bad. The J4/J5 connector may be loose. Is the right computer functioning? If not the fuse below the contactor box may be loose or blown. D. Check to see if MIB has 24V on pins 5 and 6 of J2. Check to see if 24V is present on pins 5 and 6 of wire harness plugging into J4 or J5 of the first AIF board. If 24V missing, check the pins. Replace the harness if necessary. E. Check continuity between each color wire on the CAN connectors into J7 on the far right computer and J10 on back of the ATO board (black to black, white to white, and red to red), and ensure there is no continuity between different color wires (black to red, red to white, and white to black). F. Ensure black computer locator wires are connected from ground to correct pin position (see drawing 8051734 page 1-55). G. Ensure all boards have the corner ground wire attached and tightened. H. The locator pin in J2 of the AIF board is either loose or in the incorrect position. See the charts on page 1-55 of this manual for proper pin position. I. Bad MIB and/or AIF board. J. Broken resistor lead. Unwrap the resistor leads and check ends. | p.26 |
| Actuator doesn’t function. | A. No power to the AIF board. B. Actuator is unplugged. C. AIF board failure. D. Actuator readings are out of tolerance. E. Actuator is bad | A. Check pins 5 and 6 of J2 at the MIB board. Should read 24VDC. Check voltage on pins 5 and 6 at the other end of harness and ensure 24VDC is present. Continue to check pins 5 and 6 for 24VDC on plugs J4 and J5 on the AIF boards. B. Ensure the actuator is plugged into the proper connection (J1 for FV return, J3 for DV return and J6 for FV drain and J7 for DV drain). C. Check power on the connector of the problem actuator while trying to manually open or close an actuator. Pins 1 (Black) and 4 (White) should read +24VDC when the actuator is opening. Pins 2 (Red) and 4 (White) should measure -24VDC when the actuator is closing). If either voltage is missing, the AIF board is likely bad. Test the actuator by plugging into another connector. If the actuator operates, replace the board. D. Check resistance of the potentiometer between pin 3 (purple wire) and pin 4 (gray/white wire). Closed should read 0-560Ω. Open should read 3.8K Ω – 6.6K Ω. E. If proper voltages are present at the connector and actuator doesn’t operate, reset power to the fryer. If it still doesn’t operate replace the actuator. | p.34 |
| Actuator functions on wrong vat. | A. Actuator plugged into wrong connector. B. Locator pin is in wrong position. | A. Ensure the actuator is plugged into correct connection (J1 for FV return, J3 for DV return and J6 for FV drain and J7 for DV drain). B. Ensure the locator pin is in proper position in plug J2. See table B on page 1-55. | p.34 |
| No Display on Computer. | A. Computer not turned on. B. No power to the fryer. C. Power switch turned off. D. Loose fuse holder. E. Computer has failed. F. Damaged computer wiring harness. G. Power supply component or interface board has failed. | A. Press the ON/OFF switch to turn the computer on. B. This fryer may have two cords: a computer power cord and a main power cord. If the computer cord is not plugged in, the computer will not activate. Verify computer power cord is plugged in and that circuit breaker is not tripped. C. Some fryers have a rocker power switch inside the cabinet below the computer. Ensure the switch is turned on. D. Ensure fuse holder is screwed in properly. E. Swap the computer with a computer known to be good. If computer functions, replace the computer. F. Swap with a harness known to be good. If computer functions, replace the harness. G. If any component in the power supply system (including the transformer and interface board) fail, power will not be supplied to the computer and it will not function. | p.37 |
| Computer locks up. | Computer error. | Remove and restore power to the computer. | p.37 |
| M3000 display shows filter busy. | A. Another filtration cycle is still in process. B. Computer error. | A. Wait until the previous filtration cycle ends to start another filtration cycle or until the MIB board has reset. This may take up to one minute. B. If filter busy is still displayed with no activity, ensure the filter pan is empty and remove and restore ALL power to the fryer. | p.37 |
| M3000 display shows RECOVERY FAULT. | Recovery time exceeded maximum time limit for two or more cycles. | Silence the alarm by pressing the 9 button. Check that fryer is heating properly. Maximum recovery for electric is 1:40. If this error continues to appear call your ASA. | p.37 |
| M3000 display shows ENERGY MISCONFIGURED | Wrong energy type selected in setup. | Press 1234 to enter setup and set energy type for electric. | p.38 |
| M3000 display shows EXCEPTION ERROR with the description on the right. | An error has occurred. | Press 1234 to enter setup and reconfigure the computer. | p.38 |
| M3000 displays SERVICE REQUIRED followed by the error. | An error has occurred. | Press YES to silence alarm. The error is displayed three times. See list of issues in section 1.14.3. Fix issue. The computer displays SYSTEM ERROR FIXED? YES/NO. Press YES. Computer displays ENTER CODE. Enter 1111 to clear error code. Pressing NO will allow the fryer to cook but the error will be redisplayed every 15 minutes. | p.38 |
| M3000 display is in wrong temperature scale (Fahrenheit or Celsius). | Incorrect display option programmed. | See section 1.14.2 on page 1-33 to change temperature scale. | p.38 |
| M3000 displays CHANGE FILTER PAD. | Filter error has occurred, filter pad clogged, 24 hour filter pad change prompt has occurred or change filter pad was ignored on a prior prompt. | Change the filter pad and ensure the filter pan has been removed from the fryer for a minimum of 30 seconds. Do NOT ignore CHANGE FILTER PAD prompts. | p.38 |
| M3000 display shows INSERT pan. | A. Filter pan is not fully inserted into fryer. B. Missing filter pan magnet. C. Defective filter pan switch. | A. Pull filter pan out and fully reinsert into fryer. B. Ensure the filter pan magnet is in place and if missing replace. C. If the filter pan magnet is fully against the switch and computer continues to display INSERT pan, switch is possibly defective. | p.38 |
| M3000 display shows hot-hi-1. | Frypot temperature is more than 410ºF (210ºC) or, in CE countries, 395ºF (202ºC). | This in an indication of a malfunction in the temperature control circuitry, including a failure of the high-limit thermostat. | p.38 |
| M3000 display shows HI-LIMIT. | Computer in high-limit test mode. | This is displayed only during a test of the high-limit circuit and indicates that the high- limit has opened properly. | p.38 |
| M3000 display shows low temp alternating with MLT- CYCL. | Frypot temperature is between 180°F (82°C). | This display is normal when the fryer is first turned on while in the melt cycle mode. To bypass the melt cycle press and hold either #1 or #2 cook button under the LCD display until a chirp is heard. The computer displays EXIT MELT alternating with YES NO. Press the #1 YES button to exit melt. If the display continues, the fryer is not heating. | p.38 |
| M3000 display shows ERROR RM SDCRD | Defective SD Card | Replace card with another card. | p.38 |
| M3000 display shows TEMP PROBE FAILURE. | A. Problem with the temperature measuring circuitry including the probe. B. Damaged computer wiring harness or connector. | A. This indicates a problem within the temperature measuring circuitry. Check resistance of probe, if faulty replace probe. B. Swap the computer wiring harness with one known to be good. If problem is corrected, replace the harness. | p.39 |
| MAINT FILTER (Manual Filter) won’t start. | Temperature too low. | Ensure fryer is at setpoint before starting MAINT FILTER. | p.39 |
| M3000 display shows REMOVE DISCARD. | In non-dedicated mode, a product is dropped that has a different setpoint that the current vat temperature. | Remove and discard product. Press a cook button under the display with the error to remove the error. Reset the setpoint of the vat before trying to cook product. | p.39 |
| M3000 display shows HEATING FAILURE. | Failed computer, failed interface board, open high-limit thermostat. | Turn off the vat with the issue. The error is displayed if the fryer loses its ability to heat oil. It is also displayed when the oil temperature is above 450°F (232°C) and the high-limit thermostat has opened, halting the heating of the oil. | p.39 |
| Computer will not go into program mode or some buttons do not actuate. | Failed computer. | Replace computer | p.39 |
| M3000 display shows HI 2 BAD. | Computer in high-limit test mode. | This is displayed during a test of the high- limit circuit to indicate if the high-limit has failed. | p.39 |
| M3000 display shows HELP HI-2 or HIGH LIMIT FAILURE. | Failed high-limit. | This is displayed to indicate the high-limit has failed. | p.39 |
| M3000 display shows software for only M3000 or MIB but not all boards. | Loose or damaged harness | Check that all harnesses between M3000’s, MIB, AIF and ATO are secure. Ensure 24VDC is present on pins 5 & 6 of J2 on MIB board and on J4 or J5 of AIF board. Check for loose or broken pins/wires. If the problem persists, swap out computer from one bank to another and cycle power on the fryer. | p.39 |
| M3000 display shows low temp, heating indicator cycles on and off normally but fryer does not heat. | A. Three phase power cord unplugged or circuit breaker is tripped. B. Blown fuse C. Failed computer. D. Damaged computer wiring harness. E. Open connection in high-limit circuit. | A. Ensure all cords are fully seated in the receptacles, locked into place and that circuit breakers are not tripped. B. Check three amp fuse on front of control box. C. Replace computer. D. Replace computer wiring harness. E. Check high limit circuit starting at the control box connector working to the high-limit. | p.39 |
| M3000 display shows IS VAT FULL? YES NO. | A filter error has occurred due to dirty or clogged filter pad or paper, clogged filter pump, filter pump thermal overload, improperly installed filter pan components, worn or missing O-rings, cold oil or an actuator problem. | Follow the steps in the flowchart in section 1.14.5. | p.40 |
| Fryer filters after each cook cycle. | Filter after setting incorrect or software update issue. | Overwrite the filter after setting by re-entering the filter after value in level two. Ensure that the down arrow is pressed after entering the value to save the setting (see section 4.13.5 on page 4-33 in the BIELA14 IO Manual). | p.40 |
Owners and our team usually reply within a day — and your question helps the next person too.