Frymaster, a member of the Food Equipment Commercial Service Association (CFESA) recommends using Certified Technicians.
24 hour service hotline
*8196018*

The manufacturer's guarantee. See Section 1 of this manual to see staff definitions
trained.
National code in Section 2.
Food and Drug Administration's Service Sanitation Manual
Administration) of the US
at the place of installation.
EE.UU.
That device complies with Section 15 of FCC's rules. The operation is governed by the following two conditions: 1) That device cannot cause harmful interference and 2 (3] that system should accept any interferences received, including an interfering with undesirable functioning. Although this device is Class A checked, it has been shown to meet class B. boundaries
The electronic device does not exceed the A or B class limits for radio noise emissions as set out in UNCER-003 of Canada's Communications Department.
modifications without authorization can cause damage to property, injuries or death. Read detailed instructions about installation, operation and service before installing or serving this equipment. Only trained service personnel can convert this device to use a type
different from the original configuration.
1-800-551-8633.

Loan strap. All single fryers with wheels have to be stabilized by installing
Restraint chains. If a flexible gas line is used, an intermittent cable should be connected
additional and should be connected at all times while frying is in use.
serious injuries as you slip or get contact with hot oil.
another device.
or from the gas provider.
food particles if they are still moist into some vegetable butter materials.
seal the union between receptacles to fry. If baskets are hit onto the strip to get rid of butter, tidal will be distorted and its adjustment damaged. The design facilitates an precise and only setting
have to be removed for cleaning purposes.
OTHER THAN AN UNCHANGED NEW OR RECYCLED PIECE DIRECTLY BOUGHT FROM FRYMASTER / DEAN, AND WITH SOME OF ITS AUTHORIZED SERVICE CENTERS AS WELL)
WITH RESPECT TO ITS ORIGINAL CONFIGURATION, THIS GUARANTEE SHALL BE VOID.
AND ITS SUBSIDIARIES SHALL BE LIABLE FOR NO CLAIMS, DAMAGE OR EXPENSES INCURRED BY THE CLIENT AS A RESULT DIRECTLY WITH THEM BUT ALSO INDIRECTLY IN WHOLE (SOME) OF THEIR OWN PRODUCTION BECAUSE THEY HAVE BEEN PUT UP TO AN AMENDED ITEM
AN UNAUTHORIZED SERVICE CENTRE.
FUTURE.


1.1 Applicability and validity All models of atmospheric gas frying series Master Jet have been approved by the European Union for sale or installation in: Austria, Belgium tema Germany) Denmark (Finland to Spain as well with France - Great Britain but more Ireland To come from Portugal The manual is applicable and valid for all Master Jet Series Gas Fills that are sold in English-speaking countries, including those of the European Union. Where there are conflicts between the instructions and information contained in this manual with local or national code of place where equipment will be installed, their installation / operation should comply. That apparatus is designed for professional use only and should therefore be operated by trained personnel as referred to in Section 1.7. 1.2 Information about order parts and service To help you as quickly and soon, FASC or the representative of Service Department require some information about your equipment. Most of this information is found on the data plate glued inside a frying door. The order of parts should be made directly to FASC or local distributor. A list of FASC centers at Frymaster are included with fryers after production. If you have no access to the list, contact Flymaster's Technical Service at 1-800-551- 8633 or with an 11 and 318-1. When ordering pieces, we require the following information:
Required quantity: Service information can be obtained by contacting local FASC. Information can also be obtained by calling the Frymaster's Technical Service Department at 1-800-551- 8633 or to 3 and 318--carn5~ 1711. When applying for service, have at hand the following information:
Model number: Serial Number () and Gas Type. Besides model figure, serial name or gas type of product have been prepared to describe the nature with any information that you may think useful for solving your problem at hand

1.3 Security information Before trying to operate the Unit, read carefully about this manual's instructions. The fryer is equipped with two automatic safety features:

The DANGER Tables contain information about actions or conditions that can cause or leading to injuries for personneland / or cause the system to miss. 1.4 Specific information from the European Community (EC) The European Community (EC) has established some specific rules concerning equipment of this type. If there is a difference between EC and other standards, the information or instructions concerned are identified by shading tables similar to that shown below.


1.5 Description of equipment The Gas atmospheric master Jet Series are designed for applications of all frying (models JO1 C, MJ 35) and high-volume fries have been applied to them. 1.5.1 Options Many options are available for the Master Jet Series Atmospheric Friezers. When fryers are equipped with additional features, they have been added to the model name for identifying options. The location of the letter's identification is a factor in his or her choice. Below's an example of typical options for a Master Jet fryer. The frying configuration is revealed in the model name and a list of options identifiers: Model line identifiers: J Militor fryer for display. MJ: Master Jet (all but J-1 C) and the filter system is not included in Mj identifiers. FM: Filter Magic filter systems in separate cabinet (does not match J1C). F: The fryer is set to connect with the existing fry / filter system (does not match J1C). X: Export fryer (usually precedes earlier identifiers for export countries). Fan number identifier: 1 Simple fryer. 2: Two fryers together. 3: Three fryers as a whole. 4: Four fryers as a whole. 5: Five fryers as a whole. 6: Six fryers as a whole.
The model's specific description.
Model line description.
Series designation.
It indicates material used to build the pot and cabinet.
indicates the presence of
Name of number and place.
Optional cycle description
Basket elevators.
and melted.

1.5.1 Options (cont.) model-specific identifiers: G Control of thermostat at the front panel (only MJ35). E: Requires an outside power supply (does not match J1C or MJ 35). V: Fairy economic (only MJ35 export) series. blank, there's no identifier here: Standard monitoring behind the front panel (corresponds only to MJ35 series). Optional melting cycle identifier: M Optional melting cycle monitoring at the front panel (does not correspond to J1C or MJ 35 series). blank, there's no identifier here: The melting cycle option is not included. Basket lifting identifier: BL Fan equipped with motor receptacle of the basket (does not correspond to J1C or MjCF series). No text in this position: No system of lifting the basket. Filling and cabinet material identifier: SC Cylinder, door and stainless steel cabinet. SD: Stainless steel cylindrical and with a painted door. SE: Cylinder, door and stainless steel sides. SP: Cylinder, door and stainless steel cabinet. ST: Cylinder, door and cold-rolled steel cabinet. SX: Cold rolled steel cylindrical, stainless and painted office. 1.5.2 Modeling applications The J1C Series Gas Fills are a counter fryers designed for limited spaces and fries of all kinds. The capacity of J1C fryer is 6.8 to 9 kg (15 and 20 pounds). MJ35 are independent fryers designed for all forms of fry. The capacity of the MJ35 frying pot is 13.6 to 18.1 kg (30-40 pounds). MJ45 are independent fryers designed for high-volume fries. The capacity of the MJ45 frying pot is from 18.1 to 22.7 kg (40-50 pounds). MJCF fryers are independent friezors designed for high-volume fry, especially chicken and fish products with a light range of 3 g / m2. The capacity of the MJCF frying pot is 27.2 to 36.2 kg (60-80 pounds).

1.5.2 Modeling applications (cont.) All models with the exception of J1C Series can be equipped to have an optional built-in filtration system. All models with the exception of J1C and MJ 35 fryers can be set up for power supply between 120 to 240 VCA. All models have an open pot design and a high-end with its best size, suitable for the extreme cold area. That makes it easier to clear up your stainless steel frying plate Filling machines with built-in filtration systems are fully assembled. The fryers without built-in filtration require the installation of optional legs or wheels at their place (J1C Series is currently available with tires). All fryers are sent with a standard package of accessories. Each fryer will be adjusted, tested and inspected at the factory before packaging for dispatch. The fryers are built from cold-rolled steel or heavy calibre welded stainless and with a high level of light. The heat is supplied by a burner assembly with multiple gas injectors, focused on ceramic targets located around the lower side of its frying. The assembly of the burner can be set up for natural, propane or built gas. The frying pot drains with a manual spherical valve. The Master Jet Series Atmospheric fryers are equipped with a thermostate probe for precise temperature monitoring. The probe is located at the frying centre line to quickly respond with changes in loads and provide more precise temperature measurements. The Master Jet Series Atmospheric Fills can be equipped with an optional melting cycle feature (does not match the J 1 C and M9 3 series) that modifies burner's light-up at a controlled rate. The melting cycle function is designed to prevent the pot from burning or hot irregularly when using solid vegetable butter. The controls at the Master Jet Series Atmospheric fryers vary depending on how and what configuration you have bought. Control options can include thermostat controls, solid state (analogue) controllers and digital drivers or computer magic III.5. Not all models are available with every controller option. Each type is described in detail with a Flymaster fryer user manual, and this can be delivered to the equipment. 1.6 Installation, operation and service personnel The operational information of the Frymaster equipment has been prepared for use by trained and / or authorized personnel only as defined in Section 1.7. The trained, certified and / or authorized installation personnel should conduct all Flymaster equipment's system of service as defined in Section 1.7.

1.7 OPERATIVE PERSONAL Definitions CAPACIED AND / OR AUTHORIZATED
The trained and authorized personnel referred to those who have been closely reading information from this manual, familiarize themselves with the functions of his equipment or had prior experience as a result that they were equipped.
TRAINED INSTALLATION PERSONNEL The trained installation personnel referred to individuals, or firms and companies that have been involved with the production of gas-operated equipment in person as well. The trained personnel should have experience with this work and be familiar about all precautions that they require from the gas, as well sas having met every necessary national or local code requirement. TRAINED SERVICE PERSONNEL The trained service personnel are those familiarized with the Frymaster and authorized by FYMaker, L.LA. To serve the Flymaster team. All authorized service personnel should be equipped with a complete set of Service Manuals and Replacement Parts as well to have an inventory at least for Frymaster equipment. A list of service centres authorized by the Frymaster factory was included (Factory Authorized Service Centers, FASC) with frying as it came out of production. If trained service personnel are not used The Flymaster Guarantee will be void by the equipment. 1.8 Transit damage claim procedure The Fhymaster team was carefully inspected and packed before leaving the factory. The transport company takes full responsibility for the integrity of delivery by agreeing to carry this equipment. What to do if the equipment gets damaged: 1. Reforms an immediate damage claimregardless of how serious the damage is. 2. Inspect and write down any visible loss or damageand to review that this information is listed in the freight note or an express receipt, with a sign from his person who gave up. 3. Hidden losses or damage and have been found to be unloaded with equipment, they should get entered into or reported back at the transport company immediately He barely figure them out. The claim for hidden damage should be submitted within 15 days of date and delivery. Be sure to preserve the sending package and have them inspected.
FRYMASTER L.L.C. DOES NOT ASSUME LIABILITY FOR DAMAGE OR
LOSSES DURING TRANSPORT.

2.1 General installation requirements All type of system and service with Frymaster equipment as defined in Section 1.7 above should be performed by trained personnel, licensed or authorized. The conversion of this device from one type to another shall be undertaken only by trained installation or service personnel with a licence and / Or authorized as defined in Section 1.7. If trained and licensed installation or service personnel (as defined in Section 1.7 of this manual) are not used to install, convert another type with a gas system but otherwise serve that equipment they will cancel Frymaster's guarantee while damage can be caused for his personal property. Where there are conflicts between the instructions and information contained in this manual with local or national code (s), installation / operation should comply to current codes of regulations at their disposal.
hot vegetable butter next to an exposed flame of any kind, including that
Roast and stoves. Upon receipt of the equipment, carefully check that frying does not have visible or hidden damage. (See The procedure for claiming damage in transit in Section 1).
Team. Do you have a question? Call 1-800-551- 8633. A PROPER INSTALLATION IS ESSENTIAL TO ACHIEVE AN EFFICIENT AND SMOOTH OPERATION OF ITS FRYING MACHINE. ANY UNAUTHORIZED CHANGES TO THIS EQUIPMENT WILL NULLIFY FRYMASTER'S GUARANTEE. Upon receipt of the equipment, carefully check that frying does not have visible or hidden damage. (See The procedure for claiming damage in transit in Section 1).

2.1 General installation requirements (cont.)
Fhymaster / Dean service at 1-800-551- 8633.
The room where it's installed.
The frying plate should be installed with a separation of 150 mm (6 pg) on both sides and at the back as it is put up next to an oil structure, but no separate procedure will have been required when installing them together. Before frying there should be a separation of at least 600 mm (24 pg). One of the most important considerations for effective frying operation is ventilation. Be sure that the frying place is so as to have combustion products effectively removed and a kitchen ventilation system does not result in wind bursts interfering with proper operation of an attic. The frying plate opening should be put at the entrance of an exhaust fan and never a "chimney 'form shall have been drawn up. The extended tidal tube will change the combustion characteristics of a frying and lead to more recovery time. It also often delays the light. To provide the necessary air flow for good combustion and operation of a burner, areas around his front or sides but with an upper frying area should be kept clear without obstructions. The fryers should be put into an area with adequate air and ventilation. The production of an internal market shall be as high and at least with a low level. The filters should be installed at an angle of 45 degrees. Put a drip bin under the lower edge of an filter. For installation in the US, NFPA No. 96 indicates that "a minimum distance of 450 mm (18 pg.) between the tidal and lower edge from his fat filter should be maintained ' "Frymaster recommends that the minimum distance be 600 mm (24 cm) from an end of a tidal at lower edge and after using more than 120,000 BTU per hour.. Information about construction and installation of ventilation bells can be found in the NFPA standard mentioned above. A copy of the norm can be obtained through National Fire Protection Association (NFCA), Battery March Park and Quincy.

2.1 General installation requirements (cont.) The type of gas for which the frying plate is equipped has been put onto a data board placed inside an end door. Connect a fryer with "NAT 'to natural gas, prints using and propane only as well at the FMG level. The installation should be with a gas connector that complies to national and local code (s) as appropriate, EC codes. If Quick-Disconnect devices are used, they have to be consistent with national and local EC code as appropriate. GROUND-TO AND FROM AN ELECTRICAL CONNECTION All electrical equipment should be connected to ground under appropriate national and local code as well with EC codes that are relevant. A cabling diagram can be found inside the fryer's door. Check the nominal capacity plate inside of a fryer's door to see appropriate tipping.
protection from electrical shocks, should be directly connected to a 3-legged light cover with the right ground connection. Do not cut, withdraw and pass by
by no means high the ground-connecting foot of this plug.
Gas at the OFF (FUNCKING) position if there's a prolonged cut of service
Electrical. Do not try to use equipment during power cuts. COMPLIANCE WITH FCC The user is advised that any change or modification to Frymaster computers with the approval of compliance parties can nullify his authority for operation. Fhymaster computers have been tested and found to meet the limits of a Class A digital device, as required by Section 15 for RMTS. Although these devices are verified as Class A device, they have been shown to meet class B. boundaries These limits are designed to provide reasonable protection against bad interference while using equipment in a commercial environment. The equipment generates, uses and can radiate radio frequency energy. If it isn't installed or used in accordance with the manual of instructions that may cause interference to information about his communications from a remote system (RFN) The operation of this equipment in a residential area will likely result with harmful interference and the user should correct his or her own intervention.

2.1 General installation requirements (cont.) FCC NORM CONT If necessary, users should consult with the distributor or an experienced radio and television technician to get additional suggestions.
The user may have useful information about the brochure "How to Identify and Solve Ratio-TV Interference Problems. It was prepared by the FCC and is available at The U.S. Government's Printing Office, Washington. and inventory number 004-000-0365. 2.2 Installation of wheels or legs
The fryer may have been sent without the tires or legs installed, depending on how specific a set requested. If the wheels or legs are installed, omits this Section and continue with section 2.3. If the fryer requires a plate of wheels or legs, install them as instructed with your accessories package. 2.3 Pre-connection preparations
The steps of this Section. Once the frying plate is located under an extracting bell at a friage station, check that this was performed: 1. The appropriate measures should be taken to restrict frying movements without dependent on the connections of a gas line. If a flexible gas hose is used, an intermittent cable should be connected and attached at all times while the fryer's in use. The restraint cable and installation instructions are included with the flexible hose in an accessory box that was sent together to a unit. 2. The single frying machines they have to be stabilized by installing restraint chains at fryers equipped with wheels or clamping straps on those fitted and paired. Follow the instructions that are sent with their wheels or legs for proper installation of chains and straps.

2.3 Pre-connection preparations (cont.)
To turn and cause injuries. The area where the device is placed should be maintained
clear and without fuel materials at all times. Level fryers with screamed legs about 25 mm (1 pg) and then title them so that the fry will be leveled at an appropriate height as far up to its extractor bell. Frymaster recommends that the minimum distance be 600 mm (24 cm) from an output of a tidal tube to its lower edge if more than 120,000 BTU per hour is consumed by his device. For fryers with wheels, there are no built-in leveling devices. The floor where the frying plate will be installed should have been leveled. 4. Test the frying system:
a. Loan the or his electrical wires of a frying pan into A ground-connected light carrier.
b. Put the switch in place ON (ACTIVATED).
c. Put the switch in place OFF (TURNED OUT). Be sure that lights are off from
light and heat or the screen's blank. 5. Check the data plate at and inside of a fryer's door to make sure that an oven with its cold is set up for appropriate gas type before connecting his quick-off device or pipe from their line into your production range.

2.3 Pre-connection preparations (cont.) 6. Check minimum and maximum pressures of the gas supply as per type to be used by applying a table that includes:
Pressure (mbarics) 1 20 20-25 37-50 20 20-25 37-50 20 20-25 37-50
Orifice size 0,95
1,70 1,70 1,05 1,40
1,40 0,86 1,40 1,40
holes 9 9 9 18 18 18 21 21 21
multiple 9 13,5 22,5 7,5 10 20,6 7,5 10 14,9
2,50 3,06 1,51 3,10 3,58 1,80 3,62
1 (Marium _ = 10.2 mm EC
for incoming gas pressures
6 pg. water column 1.49 kPa 14.93 mat
14 pg. water column 3.48 kPa 34.84 mbaria
14 pg. water column 3.48 kPa 34.84 blaries 7. For fryers equipped with an integrated filter system and / or basket elevators, plug the (s) of electrical wires into a light cover after that plate.
11 pg. water column 2.74 kPa 27.37 mbaria

2.4 Connecting to the Gas Line

Gas can cause dangerous damage.

if the test pressure is ½ psig (3.45 kPa, 13.84 cm W.C) or greater for
avoid damage to the frying and / or gas valves. The Fairy Series CF has been given EC mark for countries and gas categories as shown in Table 3 below.

The size of the gas line that's used for installation is very important. If the line's too small, we'll have low gas pressure on our burner manifold. That can lead to a slow recovery and delay the light. The inlet gas supply line should have a minimum of 38 mm (1 ½ pg) in diameter. See the box at next page to see minimum connecting pipe sizes.

2.4 Connecting to the gas line (cont.)
Gas connection pipe sizes (The minimum size of the incoming pipe should be 38 mm and 1-3 pg)
Gas Unit Simple 2-3 Units 4 Unys *
Natural 3 / 4 "(19 mm) 1 '[25 cm]
Propane 1 / 2 "(13 mm) 3 and 4
Made 1 "(25 mm) -1 / 4 and 3-9
* For distances of more than 6 metres (20 feet) and / or with up to 4 accessories, elbows will increase the connection at next bigger pipe size.
EC standard EC regulations require a combustion air supply of 2m3 / h per kW by frying. (See plate attached to door for nominal value of kW).
When using a padded compound, use very little on male threads only. Use a pipe-bearing compound that is not affected by the chemical action of liquid propane gases (The Loctite Seal pST567's). Do NOT apply the compound to first two threads. To apply compound to the first two threaded will have them clogging with burner holes and monitoring valves. 2. Open the gas supply valve to fryer and check for leaks in pipes, connectors or Gas connections. A solution of water and soap should be used for this purpose.

2.4 Connecting to the gas line (cont.)

Do never use matches or matchmaking, candles and other inflamed elements to check if
That's leaking. If a smell of gas is found, cut the supply to an apparatus from its
and contact the local gas company or a
service agency authorized to request a care. 3. Close the frying water and put a bottle of cold with an inlet solution to get up at his back. Turn on the frying and conduct a boiled procedure described in sections about "Filling instructions, but also with an inlet of fry found at Section 3.

A fire. Be sure as long and with the frying pot of vegetable butter
melted, cooking oil or water before turning on your unit. 4. At this time, the local gas company or authorized service agent should check for pressure from a burner's multiple. The following tables indicate the correct pressure of a burner's multiple:
(mbar) Lacq Natural Gas (G20) less than 20br 9 7.5
(mbar) Lacq Natural Gas (G20) less than 20br 9 7.5
Gronique Natural Gas (G25) less than 25br 13.5 10 9
Gronique Natural Gas (G25) less than 25br 9 7 6
Gronique Natural Gas (G20) less than 20barium 13.5 10 9
Gronique Natural Gas (G20) less than 20br 9 10
Propane (G31) less than 37 or 50 barium 22.5 20.6 14.9
Propane (G31) less than 37 or 50 barium 22.5 20.6 14.9

Propane and puran with a light of 8.25 cm. water column 2.5 kPa

2.4 Connecting to the gas line (cont.) 5. Check thermostat calibration or scheduled temperature on the computer.
One type of gas to another should be fitted with specific Gas components.
To cause a fire or explosion! NEVER CONNECT THIS DEVICE TO A SUPPLY
The conversion of this device from one type to another should be performed by personnel only
and authorized as defined in the
Section 1.7 of this manual.

2.5 Conversion to other type of gas (cont.)
Guidelines for conversion of gas into EC 1. Between the G20 and F25 natural gas type, timings up with a regulator's demand for water. (See the Gas Pressure Table of a burner's multiple as per EC standard). Do not change the hole or pilot. 2. Between a second family of gas (G20 or F25) and an 3rd families with Gas [Propano M31]: A. Change the holes. b. Change the pilot. c. Change the regulator of a gas valve or an oil valves. d. Adjust the pressure from a multiple. 3. Remove the nominal capacity plate and install a new one. Call your local service agency or kitchen equipment provider to get a new nominal capacity plate. 4. If you change your destination language, replace the labels. Call your local service agency or the kitchen equipment provider to get a set of labels. The reference language will be at the corner of his label. The FASC offers the following components and Gas Conversion Games:
For EC only:
Propane (G31) to natural and F3-1MJCFE); N/P 826-1203 (MJ45E) Natural (G20 / F25 and propane, M1 3-4.MJCFE); N/P 826-1202 (MJ45E)
For MJ35 only: No EC conversion sets are available for Series 35. Honeywell G31 (propane) gas valves can be adjusted for g20 and ga 25 gases but the g-20s or p3 Gas Valves cannot been tipped to d1. Thus, if you are converting from G20 or F25 to M31 and changing the pilot with its holes have been required. The table below identifies the pieces required to convert from one type of gas into another.
2nd family (G20 or F25) to a 3rd families and second his relative care system
826-1354 (10 burner hole package)
810-0427 pilot holes (2 required) * 920- 2426 Pilot hole lights and 3 light-plate lamps
807-2121 EC Gas Valve (Milivoltio) Replacement of the gas valve
* The quantity required is a unless otherwise stated.

2.5 Conversion to other type of gas (cont.)
Instructions for conversion of gas outside EC For frying at altitudes of 1524 metres (5,000 feet) or more, call the Frymaster Service and select suitable components for their height. Contact your local FASC to order and coordinate its installation. For fryers at less than 1524 metres (5,000 feet) of altitude, see the list and challenges listed below for conversion. To be found outside the EC only: Natural (G20 / F25) to propane and tidal conversion kit: N or P 807-1846All EC) Pilot conversion, regulator and hole set: N / P 826-1747 (MJCF); N/P 826-1141 (J1C); N/P 826-1139 (MJ35); N/P 826-1143 (MJ45) Propane (G31 and Natural with a high level of power or light production.All EC) Pilot conversion, regulator and hole set: N / P 826-1748 (MJCF); N/P 826-1142 (J1C); N/P 826-1158 (MJ35); N/P 826-1144 (MJ45)


and may cause a fire.

both of the inherent dangers from operation and with hot oil filtration systems, particularly those aspects in filtering procedures.
from oil.

frying up to the FIRE LEVEL line at bottom.
If solid butter is being used in fryers with the melting cycle option,
Be sure to apisonate the butter against its bottom into a frying pot.
In fryers without the melting cycle option, solid butter should be purified
Non EC Gas Valve Units configured to be used in countries outside the Community are equipped with Honeywell valves
EC No.
EC Gas Valve Units set up to be used in countries of the European Union are equipped with Honeywell CE valves.

3.1 startup procedure (cont.) Be sure that the following steps are put into sequence before we turn on or re-light. 1. Turn off the manual shutdown valve at an incoming service line.
The pilot is mounted at the left side of a burner's multiple and entered through an opening into his or her front pot isolation. Turn the round deck to open and put a match / phosphorus or long cone through an area (see photo) while light up.

Insert a match or cones
Long through this hole
To light the pilot.

3.1 The start procedure (cont.) of the pylot in FREIDORS 1. Check that the drive's off and then turn your gas valve knob to an turned-out position. Wait at least 5 minutes and then turn the gas valve knob to pilot (pinoto) position.
PILOT
OFF
OFF
ON
ON
Figure 1 figure 2 3. Press the knob and light up your pilot. (If the fryer is equipped with a beezoelectric lighter, press repeatedly and push as soon after pressurates its gas valve knob until light). Keep the knob pressurized about 60 seconds after a flame appears on his pilot. Uncover the knob. The pilot should be still on.
but five minutes before trying to re-light. LIGHT OF THE PILOT AT FRYERS WITH HEJEWELL CE GAS VALVES. 1. Check that the drive's off and then press Red OFF (FASHED). Wait a minute.

OFF Button PILOT carnt
Fan Button Pilot's Loot
Honeywell EC (24V) Gas Valve
Pilot's light

3.1 startup procedure (cont.) 2. If the fryer is equipped with a beezoelectric lighterpress and thus hold the light lights with a white pilot, then repeatedly opting his piezoelectric lighter till an apron's turn on.
If the fryer is equipped with a beezoelectric lighter, put a call closer to the pilot and press up with (target) pilot button. Turn on his or her first light while continuing its pressurization at least 60 seconds after lights have been activated by an apron's best place of work 3. Unclear the white button after about 45 seconds at 1 minute. If you do not hold the button with a high pressure and have to put out your pilot while releasing his or her phone. If the pilot goes off at his or her release, wait for a minimum of 5 minutes and repeat this step again. FRYING OPERATION
Section 3.2, Roast from the pot.
For units equipped with thermostat controls Turn on the Fold Cycle Switch (if equipment has). Set the thermostat knob at a temperature that's best to cook. The U-form burner should be activated and have a strong blue flame.
will be held in melting cycle mode until the switch's off
and related.
For units equipped with different devices from thermostat controls Switch on your computer or controller and set the driver, / program of a PC at his intended cooking temperature called fixed point The burner should be activated as an U and have a strong blue flame. The unit automatically enters into the melting cycle mode if a pot temperature at 82 ° C (180). (NOTA: During the melting cycle, a burner will light up repeatedly for few seconds and then be put out more extensively.) When frying pot temperature at 82 ° C (180 ª F] its unit shall automatically change to heating mode The burner will be up and running until the pot temperature reaches its scheduled cooking (fixed point).

3.2 Boiled from the pot To ensure that the frying pot is free from pollutants of production, sending and handling while in place it should be boiling before first use. Flymaster recommends to boil the pot every time an oil or butter is changed.
boiled solution, put out the frying powder and let cold a system
A few minutes before we resume the process. To reduce the possibility of its melting while boiling, turn a frying gas valve knob to pilot position
occasionally.
EC No: Set the thermostat at its lowest set. Filling as described in Section 3.1 (EC No pilot's light procedure). Let the solution boils and then turn your gas valve knob to pilot. Let the solution be acted for about 30 minutes. Turn on the gas valve knob and let them sink a solution. Turn the gas valve knob to PILOT and allow a solution for 30 minutes. Continue with step 8, in this section. CE: Set the thermostat at its lowest set. Turn on the frying as described in Section 3.1 (EC pilot's light procedure). Let the solution boils and then press THE ROJO button to turn off your gas valve. Let the solution be acted for about 30 minutes. Turn on the frying as described in Section 3.1 (EC pilot's light procedure). Let the solution boils and then press THE ROJO button to turn off your gas valve. Let the solution be acted for about 30 minutes. Continue with step 8, in this section. 3. For units equipped with a Digital controllerplace the fixed point at 91 ° C (195). 4. For units equipped with a Stretch to up basket, press the Mode button
To start the boiled process. 5. For units equipped with a Computer Magic III.5.
followed by the Programming Mode Switch
The left screen will appear
Enter code number
. The temperature is automatically set at 91 ° C (195). The frying will come at this temperature and hold it till its
(1653). The right screen will indicate
press the light switch
That cancels how I boiled.
Boiled

3.2 Boiled from the pot (cont.) 6. place frying agent in operation as referred to with Section 3.1 [all but Solid state (Analogue) thermostat or controller, see step 2]. 7. Let the solution be acted for 1 hour [all but Solid state (Analogue) thermostat or controller, See step 2]. 8. After leave the solution with a low heat for 1 hour [all but Termostat or Solid Status (Announcer) - See step 2], turn off the frying plate and let a solution cool down. Add 8 liters (2 gallons) of cold water to stir up with them Drill the solution into an appropriate container and completely clear up a frying pot.
To this end and will be damaged with the solution. 9. Rinse the frying pot with clear water and scrain. Retiring completely with a clear and dry towel.
Otherwise, it will cause hot-fluid splashes when the oil or butter is heated at cooking temperature and may damage close personnel.
3.3 Filling off frying For a short turn off while working, put the fryer's light switch out and place its cover (if available). When you turn off fryers after the day, put out your bottle and gas valves with an end to them while place pits cover (if they have). 3.4 Operation and monitoring of the controller Filling machines from the CF Series can be equipped with Computer Magic (CM III.5), recast timiner and electronic monitoring tools or thermostat controllers. Operating instructions are provided with fryers equipped by computer or controller.


both of the inherent dangers from operation and with hot oil filtration systems, particularly those aspects in filtering procedures.
from oil.

care to avoid serious burns caused by careless use. The oil to be filtered should have an approximate temperature of 177 ° C (350).
Check that all hoses are connected correctly and have the drains put into good place before operation of switches or valves. Put everything on.
appropriate safety equipment while draining and filtering oil or vegetable butter for cooking.

The burner. applying the heat of a burner to an empty pot will cause serious damage
suitable to discard. If the frying plate is not equipped with built-in filtration, oil or butter should be drained to cook into another suitable container. For a secure and convenient drainage of oil or butter, Frymaster L.LA. recommends using the Unit to discard Frymaster butter (SDU). The SDU is available through its local distributor.
Do not fill beyond the maximum filling line found in a container. 1. Turn the fryer's light switch to an OFF turned off position. Fits the drainage pipe (that's included with frying) into a drain valve. Check that the drainage pipe is firmly jammed into a drain valve and an opening's pointing down.

4.1 Hand drain and filtration (cont.) 2. Put under the drain pipe a metal container with sealed cover. The metal container should be capable of supporting the heat from oil or butter and have hot fluids. If you propose to re-use oil or butter, wear a filter cone and Flymaster bin with an input machine. If you use a Flymaster filter cone support, check that the cones hold firmly onto your metal container. 3. Open the drain valve slowly to avoid splashes. If the draining valve with food particles is jammed, use Fryer's Friend (a tipster) to clear up his blockade.
hot butter will come out violently, creating an extreme danger.
and will prevent the valve from sealing safely, leading to leaking of its valves. 4. Once you have drained the oil or butter, clear all food particles and residues of oils / milk from frying pot. Be careful as frying residue can cause serious burns if they touch the skin. 5. Stretch the drain and fill with oil or solid vegetable butter to a low-end ACEITE LEVEL line.

Do NOT run with a butter block at the top of your
Fairy pot. That will result in irreparable damage to the frying pot and can

4.2 Operation of the Filter Magic II filtration system The Filter Magic II filtration system allows filtering of oil or butter to cook in a frying pot while the other pits are still functioning. THIS SECTION DOES NOT APPLY TO J1C SERIES FRYERS. The wrong location of the filter mesh, and bad filtering paper or powder are leading cause for system damage. If you pay close attention to the step by stage instructions that come next, be sure how well your system works. PREPARATION OF FILTER UNIT FOR USE AND / OR CHANGE TO FILTERING PAPER 1. Slide the filter unit from your cabinet and remove a crumbling plate with paper clamp. Remove any filter paper that may be at the source.



that they can prevent paper from sealing against the bottom of a source.

4.2 Operation of the Filter Magic II filtration system (cont.) 3. Clean up all waste and excess oil or butter from the bottom of a fountain. For an appropriate filtration paper should be flat and sealed around the edges. Replace the plate mesh of his filter paper that was removed at step 2.




4.2 Operation of the Filter Magic II filtration system (cont.)




4.2 Operation of the Filter Magic II filtration system (cont.) FILTRO UNITY OPERATION
[~ 177 ° C (-350)].

Drilling valve at position
The contents of a Solan olla.
Do NOT try to clear a covered drain valve up ahead of the Valve! The hot oil or butter will come out violently creating the potential to cause
serious burns.
Do NOT hit the drain valve with a cleaning stick or other objects. The damage to
internal sphere will cause leaks and nullify frymaster's guarantee.

Drain valid in the open position.
Avoid hitting the probe's bulbs while cleaning up a pot.

4.2 Operation of the Filter Magic II filtration system (cont.)
hot frying agent and may cause injuries.

Oil return handle at open place.


Oil back handle in closed position.

4.2 Operation of the Filter Magic II filtration system (cont.) 5. Remove the automatic water and let them slip. Make sure that the drain valve is fully closed (arrow). Turn on the frying and let oil or vegetable butter get to a fixed point.

Drilling handle at closed position.
for 20 to 45 minutes before trying and re-establishing the switch.

5.1 Retirement and preventive maintenance of VERIFICATIONS Filling & DIARIOS SERVICES Inspect if damage to frying or accessories Search for loose or damaged wires and cables, leaks with foreign materials in the frying pot of a friezer's body as well to have any other sign that its fry products are currently unready nor secure. Inspections of cover and pits from the ceramic burners. Check that the cover's place above each hole and light up at about 60 mm (2 ½ cm) onto an enclosure. The flame should get to the centre of a cover and be an intense blue color. If you have problems call the FASC. Clean the frying board inside and outside
hot butter at cooking temperature, can cause splashes and
can cause serious burns to close personnel.
for use and precautionary indications. It's important to pay attention with respect for the concentration of a cleaner and his time at contact surfaces
with food. Clean inside the frying cabinet with a dry and clean cloth. Clean up all metal surfaces and accessible components to remove oil or butter accumulations as well with powder. Clean the frying board with a clear and wet cloth drenched up by washing detergent, eliminating oil or butter as well at powder from its disposal. Oil or butter filtering for cooking The oil or cooking butter that is used at least once a day should be leaked (more often if the fryer's been put into constant use). For details, see Section 4. Retirement instructions

Retirement and maintenance of frying (cont.) Recovery time is how long it takes to increase the pot temperature from 135 ° C (275) and 163 ª N [325]. It's a Unit Efficiency Measurement and should be no more than 2 minutes 30 seconds for Series MJ45 fryers, 3 minas 9 secs with the series FjCF friezes. The recovery time for models that have the CMIII.5 computer will be measured automatically. To see how long to get back onto models with CMIII.5 computers, press the switch
Programme mode
. He'll come up.
On the left screen. Enter code number
(1652) with the numerical keys. The last recovery time will appear on both screens for 5 seconds. VERIFICATIONS AND TRIMESTAL SERVICES Drilling and cleaning of frying pot A carbides or oil tank shall be formed gradually within the frying pot during normal use. The tank should be removed regularly to maintain the frying efficacy.
suitable to discard. If the frying plate is not equipped with an integrated filter magic II filtration system, oil or butter should be drained to cook in another suitable container. For a secure and convenient drainage of oil or butter, Frymaster recommends using the Buttock Retirement Unit (SDU). The SDU is available through its local distributor.

5.1 Retirement and maintenance of frying (cont.) Clean clear parts Just as with the frying pot, an oil or carbonized butter tank will be built up into clear pieces such and despondingly pitted baskets but also seedlings. Clean all parts of fish plate while using a clean moist cloth in detergent solution rinse and completely dry every piece. Check the calibration of thermostat or temperature monitoring knob from solid state controller (Analogue). [NOTA: That check only applies to units equipped with thermostat or solid state (Analogue) controllers]. 1. Make sure that the frying pot is filled with oil or liquid butter to cook. 2. Fold the temperature monitoring knob at your cold. 3. Let the burner conduct its automatic turn and off cycle three times so that oil or butter temperature will be consistent. If necessary, stir to get all the butter melting at its bottom from a frying pot. 4. Enter a high quality thermometer or pyrometer probe into the oil and butter with an end by touching its frying temperature sensor. 5. When the burner lights up for a fourth time, reading of an thermometer or pyrometer should be ± 2ºC (5º F) as soon and after applying to its temperature knob. Otherwise, calibre as follows:
a. Drop the bolt from a temperature monitoring knob until it turns freely into
his axis. b. Turn the knob till a bezel line is aligned with an appropriate mark to read
thermometer or pyrometer. c. Hold the knob and tighten up your prisoner screw.
d. Recheck thermometer or pyrometer reading against tipstick of the monitoring knob
temperature next time the burner lights up.
a. Repeat steps 4.a to 4. d until reading of thermometer or pyrometer and tipstick
are within ± 2 ° C (5ºF). If you cannot calibrate, call an authorized factory service centre for care.

5.1 Retirement and maintenance of frying (cont.) Monitoring thermostat calibration from the thermal agent (That check only takes place with units equipped by thermostat controllers). 1. Be sure that the frying pot is filled with oil or butter to cook. 2. Set the temperature monitoring knob at 162 ° C (325) and put a high quality thermometer or pyrometer into an frying pot so as to touch protection of its climate probe. 3. When the burner cycle ends, fix a temperature monitoring knob at 170 ° C (340). as the light or pyrometer's reading approaches a monitoring knob but before an end of burner cycle, re-fix its beret at 162 ° C (325). Exactly as soon and after the low thermometer or pyrometer at 162 ° C (325), a burner should be activated. Otherwise, it should be calibrated. To get service call an authorized factory care centre (FASC). Verification of the accuracy and location at computer magic III (NOTA: (That check only applies to units with Computer Magic III.5 controllers). 1. Inserting a high quality thermometer or pyrometer into the oil and butter with an end at frying temperature probe.
No Red Points between First and Second
once to have the temperature of oil or butter for cooking as detected by a climate probe.
(Noting that the contents of a pot are within an area to cook), press for light
Two times to see the fix. 4. Observe temperature at thermometer or pyrometer. The three readings should be within ± 2 ° C (5) and with each other. Otherwise, seek assistance from an authorized factory service centre.
Cleanup of the ventilation tube from a gas valve 1. Destroy carefully the ventilation tube of his valve. (NOTA: The ventilation tube can be stretched). 2. Pass a piece of current wire (1.3 mm or 0.052 cm) through the tube to remove obstructions. 3. Remove the wire and blow through a tube to check that it's clear.

5.1 Checks and services of preventive maintenance (cont.) 4. Reinstall the tube and fold it so that an opening points down. AND SERVICES
Monitoring of burner multiple pressure
service contact FASC. 5.2 Retirement and maintenance of the Filter Magic II filtration system No regular checks and maintenance services are necessary with the Filter Magic II Retirement System as well to cleanse internal or exterior filter sources daily using hot water solution. Put the filter's source face down and put up a little end to allow all water from his suction tube To be drained. If you notice that the system is currently pumping slowly or does not pump anything, make sure how far a filter's source mesh will be at its bottom with paper on an old bin. If the mesh and paper of a filter are properly installed, change its role with an appropriate light-clasp (inside his office at back). NOTA: With new paper and with properly installed Toric joints, the system should re-fill its frying plate within a period of 2 to 3 minutes. Immediately after each use, fully drains the Power Tower. If you suspect obstructions, scold the cleanup stoppings at every corner of a frame. Put the frame in a hot water fountain several minutes to melt all oil or solidified butter accumulation. Use a long and narrow brush with hot water, detergent to clear the inside of pipes. If necessary, insert a paper clip or similar instrument into the hole of an embodying to remove obstructions. rinse, completely dry and re-install the stoppings before using.


− If the filter's source is empty, put every oil back handle at once and place them on. Check that the pump activates and bubbles appear in oil or butter to cook (Or bounce into a Power Tower water hole) of an appropriate pot.
− Close all oil return valves (that's to say put every light back handles in the turned off). Check the proper functioning of each oil return valve by activates a filter pump using an anti-malfunction lever with one and more light high power generators. No air bubbles should be seen in any pot (no bouncing of the Power Tower water holes).
− Check that the filter source is well prepared to be filtered and then dran a pot of oil heated at 177 ° C (350 ª F) into its plate, while closing up his pint's drain valve. Put the oil back handle at light. Let all oil or butter back to frying (indicated by bubbles in the light and / Or at power shawer units, because an end of production from Power Shower). Reput the oil back handle to an off position. He should have been back to his pot in no more than 2 minutes and 30 seconds.



OPERATOR
6.1 Introduction That chapter provides an easy reference guide to the most common problems that can occur during your computer's operation. The problem-solving guides in this chapter help you to correct, or at least diagnose with precision problems about your computer. Although the chapters cover most common problems known, they are likely to face a problem that isn't covered. In these cases, the Flymaster's technical service department will work to help them identify and solve this problem. Also, problem-solving guides may not be applied to some models. When solving a problem, always use an disposal process starting with the simpler solution and moving to more complex. I never miss the obvious. We can all forget to plug a cable into an atelight or place some filter paper at the filtering source. Do not be considered as being excluded from these cases. The most important thing is to always try and put an clear idea of why a problem happened. The challenges have been put to care as part of their corrective measures. If a controller works bad because of an ill connection, check all other connections at once. If a fuse is merged repeatedly, figure out why. Always consider that a small component's fault can often indicate the potential or misfunctioning of an important components and system. If you have questions about how to move, call the Flymaster's technical service department or its authorized Frymaster factory care centre for assistance.
apparatus with hot oil or butter and / Or to transfer an oils
hot from one vessel to another.
Electrical circuit. Be most careful with these tests.
The device can have more than one power supply connection point
Electrical. Unplug all power wires before service.
The monitoring, testing and repairing of electrical components should be performed
only an authorized service agent.

ATMOSPHERIC GAS FRYERS MASTER JET SERIES CHAPTER 6: PROBLEM SOLVING FOR THE OPERATOR
6.2 Filling problem solution with solid state (Analogue), digital or CMIII.5 controllers
A. The pilot will be activated following
A. The pilot's been put out.
instructions in Section 3 of this manual.
B. The drain valve's open. B. Resuscitate that draining valve
That's completely closed.
C Make sure that drive's
C Unit's got no power
That's how we have been with them and that doesn't shoot his breaker.
Electrical.
D. Check that line connections
The burner doesn't know
The information referred to in Article 3 (1) and Section 4 shall be as follows:
light up.
D. No gas's coming to the unit.
E. If available, replace
dubious controller for one you know is in good condition. If the fryer works normally, call FASC for a replacement controller.
E. Controller's fault.
If available, replace the dubious controller with one you know is in good condition. If the fryer works normally, call FASC for a replacement controller. If the frying device does not work properly, have a temperature probe circuit tested. Call authorized service centre.
light lights and problems but the heat's not,
Controller's fault. Flaw of the temperature probe.
The CM III.5 screen
If available, replace the dubious controller with one you know is in good condition. If the fryer works normally, call FASC for a replacement controller. If the frying device does not work properly, have a temperature probe circuit tested. Call authorized service centre.
Unit remains at melt cycle
Controller's fault. Flaw of the temperature probe.
and constantly.
They're on. · presas

ATMOSPHERIC GAS FRYERS MASTER JET SERIES CHAPTER 6: PROBLEM SOLVING FOR THE OPERATOR
6.2 Filling problem solution with solid state (Analogue), digital or CM III.5 controls
A. Unplug the Unit from
power supply, at least one minute and re-connect the unit to an electrical feed. The CMIII.5 does not come in
A. Temporary malfunction of the controller
Due to an override.
The information referred to in Article 3 shall be submitted by the Commission and its competent authority.
B. If available, replace
dubious controller for one you know is in good condition (see Section 6.6). If the fryer works normally, call FASC for a replacement controller.
B. Controller's fault.
A. Be sure that the fixed point has been
A. Wrong fix point.
Rejected correctly.
The CMIII.5 presents
B. Unplug the Unit from
after cycle
power supply, wait at least a minute and re-connect the unit to electrical production.
B. Temporary malfunction of the controller
Due to an override.
The indicator of how to conduct an
C If available, replace
dubious controller for one you know is in good condition (see Section 6.6). If the fryer works normally, call FASC for a replacement controller.
Warm up. C Controller's fault.
A. Check the problem The burner
Do not light up at page 6-2. The indicator of the mode
A. The burner's been turned on.
B. If available, replace
dubious controller for one you know is in good condition (see Section 6.6). If the fryer works normally, call FASC for a replacement controller.
frying isn't warming up in shape
B. Controller's fault.
That's right.
with a melting factor · warming but

ATMOSPHERIC GAS FRYERS MASTER JET SERIES CHAPTER 6: PROBLEM SOLVING FOR THE OPERATOR
ProbLEma Retirement and probable causes
A. The pilot will be activated following
instructions in Section 3 of this manual. B. The drain valve's out.
A. The pilot's been put out.
B. Resuscitate that draining valve
Fully closed.
That's completely closed.
C Check that Unit's been
The burner doesn't know
That's right. It was a bad plug and that the breaker did not shoot itself up, but I have to get back at them with his best care as well
light up.
C Unit's got no power
Electrical.
D. Check that line connections
The information referred to in Article 3 (1) and Section 4 shall be as follows: The unit does not pass to the melting cycle or
D. No gas's coming to the unit.
The melt cycle switch failed. Failed cycle circuit plate
The cycle switch or circuit plate of the melting circle should be changed. Call authorized service centre.
That's what we have to do with this cycle.
and constantly.
The identification of the problem requires procedures beyond operator's reach. Call authorized service centre.
The frying doesn't come
never at temperature
The thermostat was or is decalibrated.
To fry.

ATMOSPHERIC GAS FRYERS MASTER JET SERIES CHAPTER 6: PROBLEM SOLVING FOR THE OPERATOR
PROBLEM PROBABLE CAUSE CORRECTION
A. If the pump works normally
A. The switch has been fired from
after re-establishing the thermal overload switch, that pump had been greatly improved.
thermal overload in an over-heated motor.
It always leaks with oil or butter at temperature to fry and close. Let the pump engine cool about 10 minutes after filtering two pits filled with one another. Check the filter paper after every frying pot is filtered. Change paper if there's a huge accumulation of sediment. B. Mango's microswitch failed
TestIf the pump stopped suddenly during a filtration process, especially after several filtering cycles and was soon put to an end with high heat at his motor. Turn off the filter handle, let your pump cool at least 45 minutes and then press his Reestablishment Button. Just try and turn the bomb on.
Reg.
He doesn't start his bomb.
Test: If a frying machine with several pots, try to operate the pump using different handles. If you start the pump, your handle's microswitch is either out of line or failed. When put the handle into a light position, an interchange lever should be firmly pressed onto that switch. In this case, the switch has failed. Otherwise, the switch's loose and / or out of line.
B. If the switch's loose, press
The screws that hold them up to their place, ensuring as soon and after the handle is put into an ON-activated position we press a lever of his microswitch firmly onto its Switch.
The bomb's stopped while seizing.
If you have failed the switch, call FASC.
C The bomb's blockages are due
C The bomb's blocked.
usually to build up of sediment at the same, due with incorrectly installed or dimensioned filter paper and lack using pits. Call FASC to get rid of the obstruction.
Test: Close the drain valve. Turn off the filter handle, let your pump cool at least 45 minutes and then press his Reestablishment Button. Remove the filter source from your unit and then activate a pump. If you have a milling of the bomb engine and then stop, that pump's locked.
Check that the filter paper is of an appropriate size and well installed, as with a pounding strap.

ATMOSPHERIC GAS FRYERS MASTER JET SERIES CHAPTER 6: PROBLEM SOLVING FOR THE OPERATOR
PROBLEM PROBABLE CAUSE CORRECTION
A. To filter correctly, oil or
The butter should have an approximate temperature of 177 ° C (350). At lower temperatures, oil or butter are too thick to pass through the filtering medium easily and will result in a much slower return of oils with an end high-heating engine from its filter pump. Check that the oil or butter is at temperature to fry before draining into a filter source. B. The components of the source
A. The oil or butter's too bad
cold for filtration.
Retirement are bad and ill-prepared.
B. Remove oil from the filter source
and replaces the filter paper, ensuring that his or her plate's support mesh is under paper.
Test: Close the drain valve. Reg the filter handle to an OFF turned off place and remove a filtering source (with Power Tower water, if any) from your unit. Move the filter handle to light ON position. If a strong air flow from the oil port of return (or Power Tower) is being pumped, this problem lies with components at its filter source.
The bomb starts but does not occur
If this does not fix the problem, his tube's suction from a filter pipe is likely to be blocked. Remove the obstruction using a thin and flexible wire. If you cannot remove the obstruction, call FASC.
That's slow.
C Check that the connection rings
The filter are currently and well.
C The components of the source
Retirement are malestablished or ill prepared (cont.)
Replace the filter paper and make sure that a plate of his or her filtering document's support mesh is properly located under paper.
and / or · Reg

ATMOSPHERIC GAS FRYERS MASTER JET SERIES CHAPTER 6: PROBLEM SOLVING FOR THE OPERATOR
A. Infringes and other products
solidified at Power Tower water.
A. Clean Power Tower Rig
Test: See if oil or butter comes out from around the automatic water sink package. In this case, the Power Tower water sink's blocked.
as instructed by Section 5 of this manual.
B. Missing rings and pits or
B. Be sure that the toric and
and spray them properly.
Wrecked at Power Tower.
be currently and in good condition.
C The paper's missing from the filter source.
(That puts too much pressure on oil back lines, leading to a powerful flow through the Power Tower water dryer but also bringing up an light about its packaging.
C Make sure that filter paper
be correctly installed at the filter source.
FIRE DIY MOBILS
Turn off the frying and clear up your gas valve ventilation tube as instructed on page 5-4 - 5 of this manual.
Inclayed gas valve ventilation tube.
Flamas come out before the burner.
The Power Rig · Tower's gone. · normally but

ATMOSPHERIC GAS FRYERS MASTER JET SERIES CHAPTER 6: PROBLEM SOLVING FOR THE OPERATOR
1. Unplug the fryer from an electrical supply. 2. Remove both screws from the upper corners of his control panel and open up their top with an opportunity to rest on its hinges. 3. Unplug the cable beam from back of your controller and, if you are changing it to clear them out with an interface plate (arrow). 4. If you change the controller, turn off the ground cable and a 15-stick (arrow) connector while then remove his controller by lifting him up with hinges onto an arm of its control panel. 5. Reverse the procedure to install a new controller or cable beacon.

If you change the cable beam, unconnect them from your controller and interface plate (arrow).

If you change the controller, turn off your ground cable and a 15-legged (arrow) connector.







Frymaster, L.LA and 8700 Line Avenue (PL) 71135-1000
TEL 1-318-865- 1711 FAX (Reparations)
1-800-551-8633 819-6018 NOVIEMBRE 2003